Loading...
HomeMy WebLinkAbout20143177.tiff LONGS PEAK WATER DISTRICT • 9875 Vermillion Road • Longmont, CO 80504 • (303) 776-3847 office • (303) 776-0198 fax August 10,2012 Ms. Ann-Elizabeth Nash Mr. Jonathan Scupin 13941 Elmore Road Longmont,CO 80504 Re: Service To Whom It May Concern; The Longs Peak Water District provides domestic water service to 13941 Elmore Road, Longmont, CO, 80504, via one standard 5/8" x 3/4" residential water tap. Service is provided in accordance with District Bylaws, Policies and Regulations, is permanent in nature and is a fully- functioning water tap without restrictions. It is my understanding that "evidence of an adequate water supply" for this property is required as part of a Change of Zone Application currently being submitted to Weld County.Please consider this letter as such evidence. Should there be any questions,or if additional information is necessary,please contact our office. 13c Regards; Barry Dykes i General Maflager • Scanning Cover Sheet • for Septic Permits Permit # G19732314 Permit Type: Health /EHS History/EHS Conversion History Situs Street Address 13941 ELMORE RD Situs City, State, Zip Sec/Town/Range: 30-03N-68W Application Status: Finaled Application Date: 03/11/1995 Parcel # (12 digits) 120730204002-R4780486 Owner Full Name: BRALY GUY Owner Address: 1127 17TH AVE. LONGMONT,CO 80501 Owner Phone#: 303 7765180 Contact Name: Contact Address: Contact Phone# Information above has been Verified in Accela by employee noted below X ,y` March 31, 2009 Processed by: Date Report ID: EHS00024v003 Page 1 of 1 Print Date-Time: 3/31/2009 10:41:10AM 7 . WELD COUNTY HEALTH DEPARTMENT y73z-3/4 1555 17th Ave. 113 /7 Greeley, Colorado B.P. No. Ph. 353-0540 M.H. No. Application for Permit to Install, Construct, Alt er e orr Repair I;nddividuuall Sewage Disposal System. / °6`7U� R4 y A//oS�,/ /2 AT G /� rrPtme 96- s/�v Legal Des�ripttiion /� 4 sc-e- ) �� k G$( Directior�L7 Sc�-ni0QE /hS Genera Information Septic Tank 1. Living Units I' 1. Liquid Capacity /0-0-12 Gallons 2. No. of Bedrooms -3 2. Dimensions W L D 3. No. of Baths // 7 3. Material 4. Basement Drain 4. Type Inlet 5. Automatic Dishwasher IC Type Outlet 6. Garbage Disposal YrS 7. Automatic Laundry yips Secondary Treatment 8. Size of Lot ( �C �w�`- 9. Type of Soil P- j Field cc0 /red64e7 10. Percolation Test f 4-'1,--r,(�f IVS (n'u 1.� / 11. Water Supply /-o iu G S sack. 1. No. of distribution nes 12. Lot Grade 2. Trench: Width_ Length 3. Type Filler Material 13. Water Table Depth 4. Depth of Filler Material 14. Other 5. Gravel Size 6. Type Tile 7. Depth of Cover 8. Other The Permit is to remain in full force and effect for six (6) months from date, until revoked for non-compliance. This system will be constructed in accordance with the above specifications and regulations governing non- municipal sewage disposal systems, in accordance with Regulation No. 1 of the Weld County Health De- partment. Owner cannot transfer permit. // / Owner: w/ Date: ll �.rf . C�/ ( Q73 Applies: �1-..60" The plans and specifications as shown are approved, pending payment . p f e. Sanitarian: a. I -4 Date: L . Date: Ax 96,/ //�I 23 The above system inspected and found to comply with the plan and descriptio . Installed by � 973 Sanitarian: n/r� /` 00,- l (/ PERMIT FEE ✓ j� ` ^• t.5 Received by V ' ,.„. .4 Date Please use reverse side for Plot Plano use separate sheet of paper. Ay a IW v 1-441- $44 - - ° - ID 90 - ?v - - 70 - - 40 - 1 � 3 �3 - 120 Pip ( � �a C,� a �{ 3 �iTh DEPARTME��OF HEALTH • if itp . 4% ,\`‘ ISO 1517 16 AVENUE COURT ,. 4`<(__ GREELEY, COLORADO 80631 ADMINISTRATION(303)3530586 i:ti4�. LOAN APPROVAL HEALTH PROTECTION (303)353-0635 ti, �- lipe COMMUNITY HEALTH (303)353-0639 Ls • COLORADO REQUEST NO. : 235-91 DATE RECEIVED: 12-12-91 DATE FORWARDED: 12-18-91 FEE PAID: $ 75.00 DATE: 12-12-91 TO WHOM IT MAY CONCERN: Review and inspection report regarding water and the sewage disposal system for an existing dwelling: SEND TO: Attention: Ed Kanemoto, 203 S. Main PHONE NO.: 772-2222 Longmont, Colorado 80501 ALTERNATE: INFORMATION: Address: 13941 Elmore Road, Longmont, CO 80501 Age of Septic: 1973 Legal: PT , PT _, Section 30 , Township 03 North, Range 68 West Subdivision Seemore Heights Lot 002 , Block 002 , Filing 000 Property Owner: Walston, Hal & Diane Original Owner: Braly, Guy Tank Pumped on: 11-11-91 By: Bob's Sanitation DEPARTMENTAL RECORD SEARCH: Permit No. : G-732314 Name: Braly, Guy Bathrooms: 1 3/4 Bedrooms: 3 Total Acreage: 4.00 Tank Capacity: 1000 gallons Field Size: 900 square feet Water Supply: Long's Peak Date of Final Inspection: July 31, 1973 INSPECTION COMMENTS: Date of Inspection: December 17, 1991 Soil Conditions: Dry XXX Saturated Snow-covered Residence: Occupied XXX Vacant FINDINGS: Sewage Disposal System: Satisfactory XXX Other Bacteriological Water Test: Acceptable XXX Other COMMENTS: Recommend that horse corral be moved from absorption area, livestock traffic can contribute to premature individual sewage disposal system failure.—ftDATE: December 18, 1991 SIGNATURE: ;-) ,/ SS_�,� tiG..- 3g y Environmental �i?ottec on Specialist Neither the County of Weld, nor any of its agents or employees undertake or assume any liability to the owner of the above property, to any purchaser of the above property or to any lending agency making a loan on the above property in connection with either its examination of the property or in the report. This inspection was conducted solely for the purpose of detecting health hazards observable at the time of inspection, and does not constitute a warranty that the system is without flaw or that it will continue to function in the future. Inspection requested during periods of snow cover and high soil saturation may be of questionable value to potential buyers due to adverse conditions. Water sample reports reflect the bacteriological quality of the water supply at the time the sample was taken. . _ 4 • , y1 cLil-Q-24 1I k-4 INSPECTION DATE: /Q- - /7 - J/ AREA C L_r SPECIALIST'S INSTRUCTIONS: O OT ereAtf ant &I:4 r� w 1 \�/t we !0A-An aft rauol. NEED'/.. CLOSING DATE /a -„2 7 9/ 2. 'MAIL AIL OR PICK-UP (NEW LOAN OR RE-FINANCE LOAN AP1 POVAL Request No: `� 3S- 901 Date Received: /2 - //,2 - 7/ Date Forwarded: Fee Paid: /54-'00 Date: /,2 /2 - 9/ TO WHOM IT MAY CONCERN: Review and inspection report regarding water and the sewage disposal system for an existing dwelling: / �J 1 SEND TO: „ Fri K rv,, r '-�O j - S el�Ii,lq /ice,/ PHONE lI 772 - ,2 222 �9-0 z S. lea , �o �, - ( l 0 ,eOtt) . INFORMATION-•: Address _L 39 N I es ire.QC P 21 4D-714, eV go5O/ Legal : PT PT , Sec 10 , T 3 , R e W, OvAge of Septic /17rc Subdivision See� l.�- nra i/e;gh,' c . , Lot . , Blk � , Filing_ Property Owner wo /s ., 14c; / �- 10;c-.. e_..__ Original Owner Tank Pumped on li-//-9/ BY __. ln}1`s SAN,; 1Y-g c.-,-1 DEPARTMENTAL RECORD SEARCH: . Permit #a-73,23/4 Name__G ci y 0),-014 Bathrooms /3/j Bedrooms 3 Total Acreaie 0/ _ Tank Capacity /000 gals. Field Size_ . 90p sq. ft. 'Water Supply-_/f,.gs1?eQK _ Date of Final Inspection 3i_l 1 7 3 7 INSPECTION CCh24ENTS: Date o1' Inspection 17 Dec 9/ Soil Conditions: Dry l/ Saturated _ Snow—covered Residence: Occupied, // Va'cant FINDINGS: Sewage Disposal System: Satisfactory 'Other _ Bacteriological Water Test: Acceptable i/ Other emese_ .i.^„ENTs: wawi _.- Reccan.i end i%gf fferarsr Ef.,_rei I INO✓[AL �L foe.Abc0a,hn.. 411es till Slip 4 n Con An;M$e yn or 17 AYI afwite 1-SAS, 11.44.t. DATE:DATE: 17- Dec- 9/ SIGNATURE: • Zt 3 n ironmen !eal Specialist Neither the County of Weld nor any of its agents or employees undertake or assume any liability to the owner of the above property, to any purchaser of the above property or to any lending agency making a loan on the above property in connection with either Its examination of the property or in the report. This inspection was conducted solely for the purpose of detecting health hazards observable at the time of inspection, and does not constitute a warranty that the system is without flaw or that it will continue to function in the future. Inspection requested during periods of snow cover and high soil saturation may be of questionable value to potential buyers due to adverse cnndltions. Water sample reports reflect the bacteriological quality f the water supply at the titre the sample was taken. y0% J )-1w (,co I DMZ Pl. Tt i, Art eF bx`pt,a., fon- /yawl 7-3231'f t�,M .< r 13 99-/ c Mitt V 21 / v Coan41 Emit Hello