HomeMy WebLinkAbout20142891.tiff PRELIMINARY GEOTECHNICAL SUBSURFACE EXPLORATION REPORT PROPOSED GODDARD I NVESTM ENTS PROPERTY PUD EAST OF ELM STREET AND WELD COUNTY ROAD 15% (A PORTION OF THE N %OF THE SE%OF SECTION 8,T2N, R67W OF THE 6TH P.M.) Fl RESTONE,WELD COUNTY, COLORADO SOI LOGIC#13-1098 August 16,2013 SO LOGIC SO LOGIC August 16, 2013 Water Supply, LLC 9075 Weld County Road 10 Fort Lupton, Colorado 80621 Attn: Mr. Tommy Raye Re: Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property East of Elm Street and Weld County Road 151/2 Firestone, Weld County, Colorado Soilogic Project# 13-1098 Mr. Raye: Soilogic, Inc. (Soilogic) personnel have completed the preliminary geotechnical subsurface exploration you requested for the Goddard Investments property to be developed as a single-family residential development in Firestone, Weld County, Colorado. The results of our preliminary exploration are included with this report. The subsurface materials encountered in the completed test borings consisted of approximately 4 inches of topsoil underlain by brown/beige/rust silty sand. The silty sand was slightly clayey in places in the upper part and contained sandy lean clay/clayey sand interbeds/lenses with depth, generally varied from loose to medium dense in terms of relative density and showed no swell potential at current moisture and density conditions. The silty sand extended to the bottom of boring B-1 at a depth of approximately 15 feet below present site grade. At boring locations B-2 and B-3, the silty sand extended to depths of approximately 14 and 9 feet below ground surface, respectively, and was underlain by olive/gray/rust interbedded sandstone/siltstone/ claystone bedrock of varying composition. The bedrock varied from firm to hard in consistency, showed low swell potential at in-situ moisture and density conditions and extended to the bottom of borings B-2 and B-3 at a depth of approximately 15 feet below present site grade. Groundwater was not encountered in borings B-1 and B-2 to the full depth of exploration, about 15 feet below present site grade, at the time of drilling. These borings remained dry to the depth explored when checked 24 hours after completion of drilling. Soilogic, Inc. 4350 State Highway 66 • Longmont, CO 80504• (970) 535-6144 P.O. Box 1121 • Hayden, CO 81639• (970) 276-2087 Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property-East of Elm Street and WCR 15'/ Firestone, Weld County,Colorado Soilogic# 13-1098 2 Groundwater was measured at a depth of about 10 feet below ground surface in boring B- 3 when checked immediately after drilling and approximately 24 hours later. Based on the subsurface conditions encountered and type of construction proposed, we expect the proposed lightly-loaded residential structures could be constructed with conventional spread footing foundations and floor slabs bearing on the site silty sand, lean clay/clayey sand, underlying interbedded sandstone/siltstone/claystone bedrock with low swell potential or properly-placed and compacted fill materials. With the presence of comparatively shallow groundwater in some areas of the site, care will be needed to maintain adequate separation distances between site groundwater and finish basement floor slab levels. Provided finished site grade is within 2 to 3 feet of existing grades at the site, it does not appear that raising site grades or installation of an underdrain system would be required to facilitate basement construction. The site silty sand also appears suitable for support of site pavements and exterior flatwork. Depending on finish site grading, stabilization of the pavement subgrades may be necessary to develop a suitable paving platform. With the suitable percolation rates established in the near-surface soils and depths to bedrock and groundwater encountered in the completed site test borings, conventional septic systems appear suitable to treat wastewater generated by the site residences. Pavement section design estimates are also provided. If asphaltic or Portland cement concrete pavements will be used, a final subsurface exploration and pavement design report for the interior site roadways should be completed once the roadways have been cut to approximate finish grade and utilities installed. Other preliminary opinions and recommendations concerning design criteria and construction details for the proposed site improvements are included with this report. Site-specific explorations and percolation testing should be completed for each of the individual residential structures after infrastructure development of the site has been completed in order to develop design- level information. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property-East of Elm Street and WCR 15'/ Firestone, Weld County,Colorado Soilogic# 13-1098 3 We appreciate the opportunity to be of service to you on this project. If you have any questions concerning the enclosed information or if we can be of further service to you in any way,please do not hesitate to contact us. Very Truly Yours, Soilogic, Inc. Reviewed by: �o0 REG49 ,Soo �1.Dr.. <c�� o ciso°° 4t •F•\ 9� F o : 44271 •�• �' . v 3. 4• : It Ss.," cc. yes'•NA H Darrel DiCarlo, P.E. Wolf von Carlowitz, P.E. Senior Project Engineer Principal Engineer PRELIMINARY GEOTECHNICAL EXPLORATION REPORT GODDARD INVESTMENTS PROPERTY PUD EAST OF ELM STREET AND WELD COUNTY ROAD 15% FIRESTONE,WELD COUNTY, COLORADO SOI LOGIC #13-1098 Augu& 16, 2013 INTRODUCTION This report contains the results of the preliminary geotechnical subsurface exploration completed for the Goddard Investments Property, to be developed as single-family residential, located just east of the Town of Firestone, in Weld County, Colorado. The purpose of our investigation was to describe the subsurface conditions encountered in the completed site test borings and develop preliminary recommendations concerning development of the site, design and construction of local access roadways and support of residential foundations and floor slabs. Our opinion concerning the suitability of the site soils to support on-site Individual Sewage Disposal Systems (ISDS) is also included. The conclusions and recommendations outlined in this report are based on results of the completed field and laboratory testing, our experience with subsurface conditions in this area and any other information discussed. PROPOSED CONSTRUCTION The Goddard Investments Property PUD will include a total of 15 lots ranging in size from approximately 2 to 6 acres to be developed as single-family residential. We expect site residences will be lightly-loaded one or two-story wood-frame structures constructed with full basements. Foundations loads for residences would be expected to be relatively light, with continuous wall loads less than 3 kips per lineal foot and individual column loads less than 75 kips. Wastewater generated by residences will be disposed of through on-site individual sewage disposal systems (ISDS). Construction of an all-weather surfaced or asphalt paved local access roadway system is also anticipated as part of the proposed site improvements. Small grade changes are anticipated to develop finish site grades. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 2 SITE DESCRIPTION In general, the site appears to have been used for agricultural purposes in the recent past. Undeveloped/agricultural land borders the property to the north, east and west, while rural residential development is present to the west. The development site includes a total of approximately 67 acres and is located east of the intersection of Elm Street and Weld County Road 15%, just east of the Town of Firestone in the N %z of the SE 'A of Section 8, Township 2 North, Range 67 West of the 6`h Principal Meridian in Weld County, Colorado. At the time of our site exploration, the approximate western one-half of the site appeared to have been recently tilled and was generally devoid of vegetation, while the eastern half of the site was sparsely vegetated in grasses and weeds. Overall, site drainage was toward the west-northwest. Based on review of available USGS topographic quad maps of the area, the maximum difference in ground surface elevation across the site is estimated to be on the order of about 50 feet. The Coal Ridge Ditch, a medium-sized, earth-lined irrigation lateral, was observed near the approximate south half of the eastern property boundary. This ditch was observed to be carrying water at the time of our site exploration. The site has also been drilled for oil/gas production in the past, as evidenced by several well-heads, tank batteries and other associated collection equipment both on and adjacent to the property. Evidence of prior building construction was not observed on the development parcel at the time of drilling. SITE EXPLORATION Field Exploration To develop subsurface information on the development parcel, a total of three (3) test borings were drilled to a depth of approximately 15 feet below present site grades across the property. The boring locations were established in the field by Soilogic personnel based upon a proposed development sketch plan provided by a representative of the client, using a mechanical surveyor's wheel and estimating angles from identifiable site references. The boring locations should be considered accurate only to the degree implied by the methods used to make the field measurements. A diagram indicating the approximate boring locations is included with this report. Graphic logs of each of the auger borings are also included. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 3 The test holes were advanced using 4-inch diameter continuous-flight auger, powered by a truck-mounted CME-55 drill rig. Samples of the subsurface materials were obtained at regular intervals using California barrel sampling procedures in general accordance with ASTM specification D-1586. As part of the D-1586 sampling procedure, the standard sampling barrel is driven into the substrata using a 140-pound hammer falling a distance of 30 inches. The number of blows required to advance the sampler a distance of 12 inches is recorded and helpful in estimating the consistency, relative density or hardness of the soils or bedrock encountered. In the California barrel sampling procedure, relatively undisturbed samples are obtained in removable brass liners. Samples of the subsurface materials obtained in the field were sealed and returned to the laboratory for further evaluation, classification and testing. Laboratory Testing The samples collected were tested in the laboratory to measure natural moisture content and visually or manually classified in accordance with the Unified Soil Classification System (USCS). The USCS group symbols are indicated on the attached boring logs. An outline of the USCS classification system is included with this report. Classification of bedrock was completed through visual and tactual observation of disturbed samples. Other bedrock types could be revealed through petrographic analysis. Dry density, Atterberg limits, -200 wash and swell/consolidation tests were completed on selected samples to help establish specific soil characteristics. Atterberg limits tests are used to determine soil plasticity. The percent passing the #200 size sieve (-200 wash) test is used to determine the percentage of fine grained soils (clay and silt) in a sample. Swell/ consolidation tests are performed to evaluate soil volume change potential with variation in moisture content. The results of the completed laboratory tests are outlined on the attached boring logs and swell/consolidation test summaries. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 4 SUBSURFACE CONDITIONS The subsurface materials encountered in the completed test borings consisted of approximately 4 inches of vegetation and/or topsoil underlain by brown/beige/rust silty sand. The silty sand was slightly clayey in places in the upper pail and contained sandy lean clay/clayey sand interbeds/lenses with depth, generally varied from loose to medium dense in terms of relative density and showed no swell potential at current moisture and density conditions. The silty sand extended to the bottom of boring B-1 at a depth of approximately 15 feet below present site grade. At boring locations B-2 and B-3, the silty sand extended to depths of approximately 14 and 9 feet below ground surface, respectively, and was underlain by olive/gray/rust interbedded sandstone/siltstone/ claystone bedrock of varying composition. The bedrock varied from firm to hard in consistency, showed low swell potential at in-situ moisture and density conditions and extended to the bottom of borings B-2 and B-3 at a depth of approximately 15 feet below present site grade. The stratigraphy indicated on the included boring logs represents the approximate location of changes in soil and bedrock types. Actual changes may be more gradual than those indicated. Groundwater was not encountered in borings B-1 and B-2 to the full depth of exploration, about 15 feet below present site grade, at the time of drilling. These borings remained dry to the depth explored when checked 24 hours after completion of drilling. Groundwater was measured at a depth of about 10 feet below ground surface in boring B- 3 when checked immediately after drilling and when checked approximately 24 hours later. Groundwater levels will vary seasonally and over time based on weather conditions, site development, irrigation practices and other hydrologic conditions. Areas of perched and/or trapped groundwater conditions may also be encountered at times throughout the year. Perched water is typically encountered in soils overlying less permeable soil layers and/or bedrock. Trapped water is typically encountered within more permeable zones of layered soil and bedrock systems. The location and amount of perched/trapped water can also vary over time. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 5 ANALYSISAND RECOMMENDATIONS Site Development All existing topsoil and vegetation should be removed from the roadway and any proposed overlot grading fill areas. After stripping and completing all cuts and prior to placement of any fill or overlying improvements, we recommend the exposed subgrade soils be scarified to a depth of 9 inches, adjusted in moisture content and compacted to at least 95% of the materials standard Proctor maximum dry density. The moisture content of the reconditioned subgrade soils should be adjusted to be within the range of+2% of standard Proctor optimum moisture content at the time of compaction. Fill soils required to develop the site should consist of approved low-volume-change (LVC) soils free from organic matter, debris and other objectionable materials. Based on results of the completed laboratory testing, it is our opinion the site silty sand overburden soils could be used as fill to develop the site provided care is taken to develop the proper moisture content in those materials at the time of compaction. If it is necessary to import fill material to the site, those materials should consist of approved LVC soils free from organic matter, debris and other objectionable materials. Soils imported for use in structural areas of the site should contain a minimum of 20% fines (material passing the #200 size sieve) in order to reduce the potential of those materials to pond and transmit water. Fill soils should be approved prior to use. We recommend the site silty sand and lean clay/clayey sand or similar materials be placed in loose lifts not to exceed 9 inches thick, adjusted in moisture content and compacted as recommended for the scarified soils above. Care should be taken to avoid disturbing the prepared subgrade soils and placed fill materials prior to construction of any overlying improvements. Subgrade soils which are disturbed by construction activities or allowed to become wet and softened or dry and desiccated should be removed and replaced or reworked in place prior to placement of any overlying improvements. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 6 Conventional Spread Footing Foundations Based on the materials encountered in the completed site borings and results of laboratory testing, we expect lightly-loaded residential structures could be supported on conventional footing foundations bearing on natural site soils/bedrock with low swell potential or properly-placed and compacted fill soils developed as outlined above. For design of footing foundations bearing on natural, undisturbed, site silty sand, lean clay/clayey sand or interbedded bedrock with low swell potential or properly-placed and compacted fill developed as outlined above, maximum net allowable soil bearing pressures in the range of 1,000 to 2,500 psf appear usable. Sizing footings to maintain minimum dead-load pressures between 500 and 1,000 psf may be required if footings bear on low swelling bedrock materials. Site specific explorations should be completed for the proposed site structures to help better define subsurface conditions in the building areas. Floor Slabs Based on results of the completed field and laboratory testing, we expect residence floor slabs could be supported directly on or immediately above natural, undisturbed site soils/bedrock with low swell potential or properly-placed and compacted fill soils developed as outlined above. Care should be taken to avoid disturbing floor slab subgrades prior to concrete placement. Subgrade soils expected to receive floor slab concrete should be evaluated closely prior to concrete placement. If areas of disturbed subgrade soils develop during construction, those materials should be removed and replaced or reworked in place prior to placement of the overlying improvements. Basement Construction We typically recommend maintaining a three (3) foot separation between finish floor slab elevation and measured groundwater in order to account for seasonal variations in the level of groundwater. Based on current groundwater and anticipated grading to achieve Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 7 finished site grade (assuming cuts less than 3'), it does not appear that shallow groundwater will limit or preclude the construction of full depth basements on this site. We recommend perimeter drain systems be installed around all below-grade areas to help reduce the potential for development of hydrostatic pressures behind below-grade walls and water infiltration into the basement areas. Perimeter drain systems should consist of perforated drain pipe surrounded by a minimum of six (6) inches of free-draining gravel. A filter fabric should be considered around the free-draining gravel or perforated pipe to reduce the potential for an influx of fine-grained soils into the systems. The drain pipes should be placed at approximate foundation bearing level at the high point of the system, run around the exterior perimeter of the below-grade areas with a minimum slope of 1/ inch per foot to facilitate efficient water removal and be designed to discharge to a sump pit and pump system or free outfall. If free outfalls will be considered, measures to help reduce the potential for reverse flow and animal access into the systems should be considered. Backfill placed adjacent to the below grade walls should consist of LVC-potential and relatively impervious soils which are free from organic matter, debris and other objectionable materials. The site overburden soils and thoroughly-processed interbedded bedrock could be used as fill in these areas. The backfill soils should be placed in loose lifts not to exceed 9 inches thick, adjusted to be within±2% of standard Proctor optimum moisture content and compacted to at least 95% of the materials standard Proctor maximum dry density. Excessive lateral stress can be imposed on below-grade walls when using heavier mechanical compaction equipment. We recommend compaction of unbalanced basement wall backfill be completed using light mechanical or hand compaction equipment. Utility I natal lation Bedding around utility pipelines should be placed in accordance with recommendations from the pipeline designer. Backfill soils placed above pipelines should consist of approved materials which are free from organic matter, debris and other objectionable materials. The on-site silty sand, lean clay/clayey sand and processed interbedded bedrock could be used as pipeline backfill. Pipeline backfill should be placed in Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 8 maximum 9-inch loose lifts, adjusted to within ±2% of standard Proctor optimum moisture content and compacted to at least 95% of the materials standard Proctor maximum dry density. Care will be needed to insure utilities are not placed on or above disturbed or sloughed materials. In addition, care will be needed to develop stable side slopes in pipeline trenches excavated through the silty sand overburden soils. Cuts below groundwater elevation will require dewatering to facilitate proper construction. We expect a majority of the dewatering procedures could be completed through open pumping procedures in sumps fed from ditches or sloped trench excavations. If deeper utility installation is required in areas of cleaner sands, well-point dewatering systems may be required. Individual Sewage Disposal Systems Three sets of percolation tests were completed as part of this preliminary subsurface exploration. Average percolation rates of 24.3, 33.2 and 34.6 minutes per inch were established in the near-surface soils as part of the above-referenced evaluation. In addition, neither groundwater nor bedrock were encountered within 8 feet of present ground surface in the borings completed as part of this exploration. Based on the results of percolation testing performed at this site and the subsurface stratigraphy encountered in the completed site borings, we expect conventional septic systems could be constructed for the proposed residences. Local Access Roadway We expect the subgrade soils in the area of the local access roadway will consist of silty sand with lean clay/clayey sand interbeds/lenses. The silty sand showed no swell potential at current moisture and density conditions and in our opinion could be used for support of the overlying all-weather or asphaltic concrete roadway surfacing. Roadway subgrade soils should be developed as outlined in the "Site Development" portion of this report. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 9 The load-carrying capacity of all-weather surfacing and/or asphalt pavements would be most dependent on subgrade strength. Care will be required at the time of construction to ensure stable subgrade soils are developed immediately prior to surfacing/paving. The site silty sand and lean clay/clayey sand would be particularly susceptible to strength loss and instability when elevated in moisture content with a tendency to rut and pump when wetted. Depending on the time of year when construction occurs and other hydrologic conditions, stabilization of site pavement subgrades may become necessary to develop a suitable paving platform. If required, we recommend consideration be given to stabilization of the pavement subgrades with Class C fly ash. Fly ash stabilization can also eliminate some of the uncertainty associated with attempting to pave during periods of inclement weather. Care should be taken to develop adequate drainage across the surface of the roadway and away from the edges of the pavements. Water which is allowed to pond on or adjacent to the roadways can result in a loss of subgrade support and unsatisfactory performance over time. Materials used to develop all-weather surfaced areas should consist of select granular materials meeting Colorado Department of Transportation (CDOT) Class 5 or 6 sieve analysis specifications. Aggregate base, recycled asphalt pavement (RAP) or recycled concrete materials could be considered for use. We recommend a minimum of six (6) inches of granular surfacing be developed for all-weather surfaced roadway pavements. For preliminary design estimates, if asphaltic concrete pavements will be used, a pavement section consisting of 4 inches of asphaltic concrete overlying 6 inches of aggregate base course could be used for preliminary estimates for local residential roadways. Aggregate surfacing should be placed in loose lifts not to exceed 9 inches thick, adjusted to within +2% of standard Proctor optimum moisture content and compacted to at least 95% of the material's standard Proctor maximum dry density. Asphaltic concrete should be placed and compacted in accordance with Town of Firestone guidelines. With the intrinsic qualities of gravel-surfaced drive/parking areas, periodic maintenance efforts should be expected. Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 10 Drainage Positive drainage is imperative for long term performance of any proposed site structures and associated site improvements. We recommend positive drainage be developed away from all site structures and pavement areas to reduce the potential for wetting of the foundation bearing and pavement subgrade soils. Water which is allowed to pond adjacent to site improvements can result in unsatisfactory performance of those improvements over time. LIMITATIONS This report was prepared based upon the data obtained from the completed site exploration, laboratory testing, engineering analysis and any other information discussed. The completed borings provide an indication of subsurface conditions at the boring locations only. Variations in subsurface conditions can occur in relatively short distances away from the borings. This report does not reflect any variations which may occur across the site or away from the borings. If variations in the subsurface conditions anticipated become evident, the geotechnical engineer should be notified immediately so that further evaluation and supplemental recommendations can be provided. The scope of services for this project does not include either specifically or by implication any biological or environmental assessment of the site or identification or prevention of pollutants or hazardous materials or conditions. Other studies should be completed if concerns over the potential of such contamination or pollution exist. The geotechnical engineer should be retained to review the plans and specifications so that comments can be made regarding the interpretation and implementation of our geotechnical recommendations in the design and specifications. The geotechnical engineer should also be retained to provide testing and observation services during construction to help determine that the design requirements are fulfilled. This report has been prepared for the exclusive use of our client for specific application to the project discussed and has been prepared in accordance with the generally accepted standard of care for the profession. No warranties express or implied, are made. The Preliminary Geotechnical Subsurface Exploration Report Goddard Investments Property PUD -E. of Elm Street and WCR 15'72 Firestone, Weld County, Colorado Soilogic# 13-1098 11 conclusions and recommendations contained in this report should not be considered valid in the event that any changes in the nature, design or location of the project as outlined in this report are planned, unless those changes are reviewed and the conclusions of this report modified and verified in writing by the geotechnical engineer. o_ AUGUST 2013 BORING LOCATION DIAGRAM SO LOGIC PROJECT # 13-1098 :firestone @ a N 1 2 3 >. C7 O O w 6 5 4 f 60' ROW 0 T @ J v O g @ A N 6 ' OI > _ a L L a -C rn •m E O _a v N Vj 1 2 3 C B-1 PERCOLATION TFST RFSI TS E NOT TO SCALE 1 = 40.0 MIN/INCH ` 2 = 30.0 MIN/INCH 6 5 4 3 = 40.0 MIN/INCH 4 = 45.0 MIN/INCH 5 = 30.0 MIN/INCH j 6 = 22.5 MIN/INCH - C.1 B-3 PERCOLATION TEST RESULTS AVG = 34.6 MIN/INCH 1 = 45.0 MIN/INCH 2 = 36.0 MIN/INCH B-2 PERCOLATION TEST RESULTS 3 = 32.7 MIN/INCH I = 22.5 MIN/INCH 1 2 3 4 = 32.7 MIN/INCH � , 2 = 27.7 MIN/INCH c 5 = 20.0 MIN/INCH 3 = 25.7 MIN/INCH , 6 = 32.7 MIN/INCH 4 = 36.0 MIN/INCH 6 5 4 AVG = 33.2 MIN/INCH 5 = 18.9 MIN/INCH 6 = 15.0 MIN/INCH Irrigation AVG = 24.3 MIN/INCH headgate and Pond 4 GODDARD INVESTMENTS PROPERTY PRELIMINARY & PERCOLATION TESTING EAST OF ELM STREET AND WELD COUNTY ROAD 15.5, FIRESTONE, COLORADO GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5,FIRESTONE,COLORADO Project13-1098 August 2013 SO LOGIC LOG OF BORING B-1 Sheet 1/1 Drilling Rig: CME 55 Water Depth Information Start Date 7/30/2013 Auger Type: 4"CFA During Drilling None Finish Date 7/30/2013 Hammer Type: Automatic After Drilling None Surface Elev. - Field Personnel: DJD/BMc 24 Hours After Drilling None N 2 Estimated Swell %Passing SOIL DESCRIPTION Depth E "N" MC DD q„ %Swell @ Pressure Atterberg Limits #200 Sieve (ft) m" (%) (pcf) (psf) 500 psf (psf) LL PI (%) 0-4"VEGETATION&TOPSOIL - 1 2 3 4 5 CS 10 3.8 100.1 N/A None <500 - -SM SILTY SAND - brown,beige,rust 6 loose to medium dense - slightly clayey in places 7 8 9 10 CS 11 2.5 94.0 N/A None <500 - - - 11 12 13 with contains SANDY LEAN CLAY to - CL-SC CLAYEY SAND lenses 14 with depth - 15 CS 22 4.6 119.9 7000 -BOTTOM OF BORING @ 15.0' - 16 17 18 19 20 21 22 23 24 25 GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5,FIRESTONE,COLORADO Project13-1098 August 2013 SO LOGIC LOG OF BORING B-2 Sheet 1/1 Drilling Rig: CME 55 Water Depth Information Start Date 7/30/2013 Auger Type: 4"CFA During Drilling None Finish Date 7/30/2013 Hammer Type: Automatic After Drilling None Surface Elev. - Field Personnel: DJD/BMc 24 Hours After Drilling None N 2 Estimated Swell %Passing SOIL DESCRIPTION Depth E "N" MC DD q„ %Swell @ Pressure Atterberg Limits #200 Sieve (ft) m" (%) (pcf) (psf) 500 psf (psf) LL PI (%) 0-4"VEGETATION&TOPSOIL - 1 2 3 4 5 CS 12 5.7 104.3 N/A None <500 NP NP 15.4% SM SILTY SAND - brown,beige,rust 6 loose - slightly clayey in places 7 8 9 10 CS 12 2.7 107.9 N/A None <500 - - - 11 12 13 14 SILTSTONE with CLAYSTONE - olive,gray,mediumhard 15 CS 40 16.4 113.2 9000+ . BOTTOM OF BORING @ 15.0' - 16 17 18 19 20 21 22 23 24 25 GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5,FIRESTONE,COLORADO Project13-1098 August 2013 SO LOGIC LOG OF BORING B-3 Sheet 1/1 Drilling Rig: CME 55 Water Depth Information Start Date 7/30/2013 Auger Type: 4"CFA During Drilling 10.0' Finish Date 7/30/2013 Hammer Type: Automatic After Drilling 10.0' Surface Elev. - Field Personnel: DJD/BMc 24 Hours After Drilling 10.0' N 2 Estimated Swell %Passing SOIL DESCRIPTION Depth E "N" MC DD q„ %Swell @ Pressure Atterberg Limits #200 Sieve (ft) m" (%) (pcf) (psf) 500 psf (psf) LL PI (%) 0-4"VEGETATION&TOPSOIL - 1 2 3 SM SILTY SAND 4 brown,beige,rust - loose 5 CS 6 24.3 98.7 N/A - - - -slightly clayey in places - 6 7 8 9 10 CS 32 17.7 107.1 9000+ None <500 - - - Interbedded 11 SANDSTONE/SILTSTONE/CLAVSTONE - olive,gray,rust 12 firm to hard - very well-cemented tense at 11'depth 13 14 15 CS 50/9" 13.0 114.0 9000+ 1.1% 1200 BOTTOM OF BORING @ 15.0' - 16 17 18 19 20 21 22 23 24 25 GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5, FIRESTONE, COLORADO Project# 13-1098 August 2013 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 0 4 2 0 •- -4 O 72 -6 0 v 8 -10 -12 10 100 1000 10000 100000 Applied Load(psf) Sample ID: B-1 @ 4' Sample Description: Rusty Brown Silty Sand (SM), slightly clayey Initial Moisture 3.8% Liquid Limit - Final Moisture 17.0% Plasticity Index - % Swell @ 500 psf None % Passing#200 - Swell Pressure <500 psf Dry Density 100.1 pcf SO LOGIC GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5, FIRESTONE, COLORADO Project# 13-1098 August 2013 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 4 2 0 •- -4 72 -6 0 v 8 -10 -12 10 100 1000 10000 100000 Applied Load(psf) Sample ID: B-1 @ 9' Sample Description: Brown/Rust/Beige Silty Sand (SM) Initial Moisture 2.5% Liquid Limit - Final Moisture 19.9% Plasticity Index - % Swell @ 500 psf None % Passing#200 - Swell Pressure <500 psf Dry Density 94.0 pcf SO LOGIC GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5, FIRESTONE, COLORADO Project# 13-1098 August 2013 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 4 2 0 • -4 O 0 -6 v 8 -10 -12 10 100 1000 10000 100000 Applied Load(psf) Sample ID: B-2 @ 4' Sample Description: Rusty Brown Silty Sand (SM), slightly clayey Initial Moisture 5.7% Liquid Limit NP Final Moisture 17.9% Plasticity Index NP % Swell @ 500 psf None % Passing#200 15.4% Swell Pressure <500 psf Dry Density 104.3 pcf SO LOGIC GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5, FIRESTONE, COLORADO Project# 13-1098 August 2013 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 4 2 0 •- -4 72 -6 0 v 8 -10 -12 10 100 1000 10000 100000 Applied Load(psf) Sample ID: B-2 @ 9' Sample Description: Rusty Brown Silty Sand (SM) Initial Moisture 2.7% Liquid Limit Final Moisture 17.9% Plasticity Index % Swell @ 500 psf None % Passing#200 Swell Pressure <500 psf Dry Density 107.9 pcf SO LOGIC GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5, FIRESTONE, COLORADO Project# 13-1098 August 2013 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 0 4 2 0 2 ,'1_11_0.-_:91=1 -4 701 72 -6 0 v 8 -10 -12 10 100 1000 10000 100000 Applied Load(psf) Sample ID: B-3 @ 9' Sample Description: Olive/Gray Sandstone/Siltstone/Claystone Initial Moisture 17.7% Liquid Limit - Final Moisture 19.0% Plasticity Index - % Swell @ 500 psf None % Passing#200 - Swell Pressure <500 psf Dry Density 107.1 pcf SO LOGIC GODDARD PROPERTY PRELIMINARY EAST OF ELM STREET&WCR 15.5, FIRESTONE, COLORADO Project# 13-1098 August 2013 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 4 2 0 �- -4 0 -6 v 8 -10 -12 10 100 1000 10000 100000 Applied Load(psf) Sample ID: B-3 @ 14' Sample Description: Olive Siltstone/Claystone Initial Moisture 13.0% Liquid Limit - Final Moisture 17.8% Plasticity Index - % Swell @ 500 psf 1.1% % Passing#200 - Swell Pressure 1,200 psf Dry Density 114.0 pcf SO LOGIC UNIFIED SOIL CLASSIFICATION SYSTEM . • (USCS) ^ Coarse-Grained Grovels more than Clean Gravels Less Soils more thou 50% of coarse than 5% fines Cu2.4 and cCr.<3r CW Well-graded grovel` 50% retained on fraction retained No. 200 sieve - on No. 4 sieve Cu<4 and/or 1>Cc>3i GP Poorly-graded grovelr Grovels with Fines Fines classify as ML or MH GM Silty grovel, G,H more than 12% - fines - Fines classify as CL or CH CC Clayey Grovel'''. Sands 50% or Clean Sands Less Cu> and 1<Ge S3` Sly 'Neff-graded fond' more coarse than 5% fines fraction passes Cues and/or 1>Cc>3. SP Poorly-graded sand' No. 4 Sieve -`"` Sands with Fines Fines classify os 4L or LH SM Silty send`"' more lhnn 12% - - • lines f-rrles classify os CL or CH SC Clayey sonde'" Fine—Grained Silts and Cloys inorgonic Pt>7 and plots on or above 'A-Line' CL Leon CIO/'-" Soils 50% or Liquid Limit less -- more passes the than SO _ PI<4 or plots below 'A"Line' ML Silt." No. 200 sieve orgonic Liquid Llnil — oven dried Organic clay1y. <0.75 OL Liquid Limit — not dried Orgonlc silt"" Sills and Clays inorganic PI plots on or above .A-Line CH Fat clay<e" Liquid Limit 50 or • more PI plats below "A'Line MR Elastic Sift e`< organic liquid Limit — oven dried Oryonic deye"r <0.75 OH Liquid Limit — not dried Organic sltt"" Highly organic sails Primariy organic motler, dark ci color, and organic odor PT Peal eeo{ed en the mptenal poseilg the 3-n.(y5- 'CreD.,10,Ca- O x U 'u ea...roof is to 28 spun we. 207.add awn)aiew 'with toner°r MIN grovel'.whichever is hI field wimple ee1lsined cobbles or boulders. p'eCIOnw°nt. w boll,odd'with cObbtee or bouldcre,e.both' -II soi Centeno,y 70-pros me,200 In group name. 'll fop canteens y15x fond.oderellh•sond-lo Prediminently wood.odd fonds to Term l GInrels with 5 to 12X ri<s mooned Weal np..: symbol{: `group o`..slit os CL-4L.ion duel bol 1'sop contains 2,. plus No. 400 OW-GLl well growled grovel wilt.wilt GC-CY,or SC Su. sym ysepminanlry waver. roe gravely Is warp GW-GC wen-graded grovel rim clay RI fins yre argent.,add-wills orgonic !Insilco pwe. GP-co pasty-graded grovel with sal wows nWnr `Pile and pleas on or-ebeve-A NW. GP-ac poorly-Tpdee grovel with Slay ill roe coMuns rl.itwrvrl. Wei-wall growef- :Pile or pots LNo• A GM. `Sonde with S to 12%noes.tgOre dual la sup name. 'Pi plats or above ll-Inc {lmbale' Ili yore rio,.,.. 1' pols ?. .p.bohn ii Atl Rbue rrme,plots neodea arta, soi is n M plats lidos-A'1;414. SW-At rep-graded wee-Im XI CL-ML.Silly New. SW-SC well-eroded sane wIth cloy SP-Su poorly Toted fond with sat .SP-;C poorly Todet IOW! ..tin Lip). f.an;';.! al"."fine..;M<re:r ' 72ri1 f `- -.e Me-yr"ee .�.,. r.-•is uwysA F we. -a ILL-rnl 44,>,.r/1'�, P LL Lexten et V-e. •Woe vt ll-le /WT. �di_�_ X s° lows ei wl.III to _._-..- n G Z r • c . I C.1\' MH01fi • 10 i t —1 YL t. M _ ,401_ 1 i r ;�.....�. -._1._,._..i1 °e WI To 1p .d so Ie 1—ii- eo eu la eel C101JID L:MIT (LL) i .....- Fine Grained Soils Coarse Grained Soils fiedroek Qv(poi) _ Consistency Blows/ft Relative Density 8lowxfft —` Weathering <500 Very Soft 0-4 Very Looce 0-511` Weathered 400.1000 Soft 5.8 Loose 50° Competent 1001.2000 Medium Stiff 9-12 Slightly Dense Degree of Weathering 2001.4000 Stiff 13.30 Medium Dense Slight. Slight decomposition,possible color change 4001.8000 Very Stiff 31.50 Dente Moderate. Some decomposition and color change throughout 8001.16000 Very Hard 50• Very Dense High. Rock highly decomposed,may be extremely broken GENERAL NOTES DRILLING&SAMPLING SYMBOLS: SS: Split Spoon- 1%" I.D.,2"O.D., unless otherwise noted HS: Hollow Stem Auger ST: Thin-Walled Tube—2.5"O.D., unless otherwise noted PA: Power Auger RS: Ring Sampler-2.42" I.D., 3"O.D., unless otherwise noted HA: Hand Auger CS: California Barrel- 1.92"I.D.,2.5"O.D., unless otherwise noted RB: Rock Bit BS: Bulk Sample or Auger Sample WB: Wash Boring or Mud Rotary The number of blows required to advance a standard 2-inch O.D. split-spoon sampler(SS)the last 12 inches of the total 18-inch penetration with a 140-pound hammer falling 30 inches is considered the "Standard Penetration" or "N-value". For 2.5" O.D. California Barrel samplers (CB) the penetration value is reported as the number of blows required to advance the sampler 12 inches using a 140-pound hammer falling 30 inches, reported as "blows per inch," and is not considered equivalent to the "Standard Penetration"or"N-value". WATER LEVEL MEASUREMENT SYMBOLS: WL: Water Level WS: While Sampling WCI: Wet Cave in WD: While Drilling DCI: Dry Cave in BCR: Before Casing Removal AB: After Boring ACR: After Casing Removal Water levels indicated on the boring logs are the levels measured in the borings at the times indicated. Groundwater levels at other times and other locations across the site could vary. In pervious soils, the indicated levels may reflect the location of groundwater. In low permeability soils,the accurate determination of groundwater levels may not be possible with only short-term observations. DESCRIPTIVE SOIL CLASSIFICATION: Soil classification is based on the Unified Classification System. Coarse Grained Soils have more than 50% of their dry weight retained on a#200 sieve; their principal descriptors are: boulders, cobbles, gravel or sand. Fine Grained Soils have less than 50% of their dry weight retained on a#200 sieve; they are principally described as clays if they are plastic, and silts if they are slightly plastic or non-plastic. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. In addition to gradation, coarse-grained soils are defined on the basis of their in-place relative density and fine-grained soils on the basis of their consistency. FINE-GRAINED SOILS COARSE-GRAINED SOILS BEDROCK f� fal f� f�S Relative f�B f�S Blows/Ft. Blows/Ft. Consistency Blows/Ft. Blows/Ft. Density Blows/Ft. Blows/Ft. Consistency <3 0-2 Very Soft 0-5 <3 Very Loose < 24 <20 Weathered 3-5 3-4 Soft 6-14 4-9 Loose 24-35 20-29 Firm 6-10 5-8 Medium Stiff 15-46 10-29 Medium Dense 36-60 30-49 Medium Hard 11-18 9-15 Stiff 47-79 30-50 Dense 61-96 50-79 Hard 19-36 16-30 Very Stiff >79 >50 Very Dense > 96 >79 Very Hard >36 >30 Hard RELATIVE PROPORTIONS OF SAND AND GRAIN SIZE TERMINOLOGY GRAVEL Descriptive Terms of Percent of Major Component Other Constituents Dry Weight of Sample Particle Size Trace < 15 Boulders Over 12 in. (300mm) With 15—29 Cobbles 12 in.to 3 in. (300mm to 75 mm) Modifier >30 Gravel 3 in.to#4 sieve(75mm to 4.75 mm) Sand #4 to#200 sieve(4.75mm to 0.075mm) Silt or Clay Passing#200 Sieve(0.075mm) RELATIVE PROPORTIONS OF FINES PLASTICITY DESCRIPTION Descriptive Terms of Percent of Other Constituents Dry Weight Term Plasticity Index Trace <5 Non-plastic 0 With 5-12 Low 1-10 Modifiers > 12 Medium 11-30 High 30+ 7 SO LOGIC Hello