HomeMy WebLinkAbout20141910.tiff kw
KerrNtGee
Kerr-McGee Oil&Gas OnShore LP
A subsidiary of Anadarko Petroleum Corporation
m
109918 Street
Denver,CO 80202
(720)929-6000
January 9th,2013
Weld County Department of Planning Services
Attn: Kim Ogle
1555 N 17th Avenue
Greeley,Co 80631
RE: Wattenberg SWD Closure Plan
Section 19—T2N—R66W: NW SW
W
Dear Mr.Ogle:
Kerr-McGee Oil&Gas Onshore LP, a wholly owned subsidiary of Anadarko Petroleum Corporation
(APC) is proposing to plug and abandon the Wattenberg SWD Well in Weld County.
We have provided a closure plan with this document as well as the Form 6 that was submitted to the
COGCC. This document outlines the plugging procedures for the well.
Should you have any questions or need additional information regarding this matter please do not
hesitate to contact me at 720-929-6896.
Thank you for your time.
RECEIVED
Regards, JUN 17 2014
WELD COUNTY
COMMISSIONERS
Nathan S. Keiser
Municipal Planning Analyst
/jthrn 2014-1910
�o u..7i
'02.3-02O/y
PLORn
Wattenberg SWD#1
Closure Plan
All operations regarding the plugging and abandonment of the Wattenberg SWD#1 well are planned
and conducted with safety as the top priority. Under no circumstances will the safety of any person or
the environment be compromised during this process. Additionally, all procedures will be in accordance
with regulations set by the Environmental Protection Agency(EPA), Colorado Oil and Gas Conservation
Commission (COGCC),the Colorado Department of Public Health and Environment(CDPHE),and Weld
County.
Reclamation
All structures including storage tanks,concrete pads, road base and location dirt,will be removed and
either disposed of or recycled. Facilities on location will be tested for asbestos. If asbestos is
encountered, it will be remediated according to guidelines set for the by the CDPHE. If applicable,a
demolition permit will be obtained through the CDPHE and Weld County.
Upon the abandonment of the Wattenberg Salt Water Disposal#1 location,Anadarko Petroleum/Kerr-
McGee will reclaim the area as soon as practicable,and no later than twelve months per COGCC
regulation 1004.a.The location will be planted with a native seed mixture to match the surrounding
vegetation.The area will also be stabilized by crimping a certified weed free straw into the soil.The
location will be considered successfully reclaimed when the vegetation density surpasses 80%of the
pre-disturbance level excluding noxious weeds per COGCC regulation 1004.c.(2).At that time a Form 4
Sundry Notice will be submitted to the COGCC, providing details of the reclamation per regulation
1004.c.(4).
In the event that hydrocarbon impacts are discovered during the deconstruction and abandonment of
the facility,soil and shallow groundwater(if encountered)assessment activities will be conducted to
ensure compliance with the COGCC Rules. In addition, if the potential impacts are deemed to be
reportable per COGCC Rules,then the applicable notifications will be provided to the COGCC(and Weld
County,as appropriate).
FORM State of Colorado CE ET OE ES
6 Oil and Gas Conservation Commission '" >
Rev 11201 incoln Sheet.Suite 801.Denver,Colorado 80203 Phone:(303)890-2100 Fax:(303)890-2109
GAS Document Number:
12/05 „GAS
WELL ABANDONMENT REPORT 400489982
This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete,this
form shall again be submitted as a Subsequent Report of the actual work completed.The approved intent shall be valid for six months after the approval
date,after that period,a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration Date Received:
and the proposed configuration with plugs set.
A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellborn 10/03/2013
diagram srrowing pugs that were set and casing remaring in the hole,the Pb summaries horn WI pugging contractors used,including*reline and
cementing(third party verification)and any logs that may have been run during abandomenl.
OGCC Operator Number: 47120 Contact Name: CHERYL LIGHT
Name of Operator: KERR-MCGEE OIL&GAS ONSHORE LP Phone: (720)929-6461
Address: P O BOX 173779 Fax: (720)929-7461
City: DENVER State: CO Zip: 80217- Email: CHERYL.LIGHT@ANADARKO.COM
For"Intent"24 hour notice required, Name: PRECUP,JIM Tel: (303)726-3822
COGCC contact: Email: james.precup@state.co.us
API Number 05-123-15621-00
Well Name: WATTENBERG SWD Well Number: 1
Location: QtrQtr: NWSW Section: 19 Township: 2N Range: 66W Meridian: 6
County: WELD Federal,Indian or State Lease Number:
Field Name: WATTENBERG Field Number: 90750
R Notice of Intent to Abandon Subsequent Report of Abandonment
Only Complete the Following Background Information for Intent to Abandon
Latitude: 40.122012 Longitude: -104.828417
GPS Data:
Date of Measurement: 10/19/2006 PDOP Reading: 1.8 GPS Instrument Operator's Name: Chris Fisher
Reason for Abandonment: Dry Production for Sub-economic Mechanical Problems
IK Other Injection is sub-economic
Casing to be pulled: Yes r No Estimated Depth:
Fish in Hole: Yes r No If yes,explain details below
Wellbore has Uncemented Casing leaks: Yes r No If yes,explain details below
Details: There is a short casing liner cemented from 8,395'to 7,756'and tubing is also cemented inside of that liner. That tubing also
has a bridge plug.
For clarity,the 2nd string listed in the Casing History is Tubing that is cemented in. The proposed procedure is to cut the
tubing at 7,500'and leave the rest cemented.
For questions or further clarification please contact Michael Sax(970-339-1449).
Current and Previously Abandoned Zones
Formation Perf Too Fed.Btm Abandoned Date Method of Isolation Plua Depth
ENTRADA 8444 8462
LYONS 9029 9104 02/02/2004 B PLUG CEMENT TOP
Total:2 zone(s)
Casing History
Date Run:10/22/2013 Doc(9400489982)Well Name:WATTENBERG SWD 1 Page 1 of 3
Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement Bot Cement Top Status
SURF 12+1/4 8+5/8 24 790 650 790 0 visu
1ST 7+7/8 5+1/2 17 9,037 230 9,037 7,994 VISU
2ND 4+0/1 2+3/8 4.7 8,277 12 8,277 7,675 VISU
1ST LINER 5+1/2 4+0/1 10.46 7,756 7 8,395 7,754 VISU
le d s..a.1.:,,, , ...g. r,' s `:it2. Stage Tool 3,504 795 3,504 0 VISU
Plugging Procedure for Intent and Subsequent Report
CIBP#1:Depth 7450 with 70 sacks cmt on top.CIPB#2: Depth 6600 with 270 sacks cmt on top.
CIBP#3:Depth 150 with 12 sacks cmt on top.CIPB#4: Depth with sacks cmt on top.
CIBP#5:Depth with sacks cmt on top. NOTE:Two(2)sacks cement
required on all CIBPs.
Set 25 sks cmt from 740 ft.to 500 ft. Plug Type: CASING Plug Tagged: r
Set sks cmt from ft.to ft. Plug Type: Plug Tagged:
Set sks cmt from ft.to ft. Plug Type: Plug Tagged:
Set sks cmt from ft.to ft. Plug Type: Plug Tagged:
Set sks cmt from ft.to ft. Plug Type: Plug Tagged:
Perforate and squeeze at ft.with sacks.Leave at least 100 ft.in casing CICR Depth
Perforate and squeeze at ft.with sacks.Leave at least 100 ft. in casing CICR Depth
Perforate and squeeze at ft.with sacks.Leave at least 100 ft.in casing CICR Depth
(Cast Iron Cement Retainer Depth)
Set sacks half in. half out surface casing from ft.to ft. Plug Tagged:
Set 12 sacks at surface
Cut four feet below ground level,weld on plate Above Ground Dry-Hole Marker: Yes r No
Set sacks in rat hole Set sacks in mouse hole
Additional Plugging Information for Subseauent Report Only
Casing Recovered: ft.of inch casing Plugging Date:
'Wireline Contractor. *Cementing Contractor:
Type of Cement and Additives Used:
Flowline/Pipeline has been abandoned per Rule 1103 Yes No *ATTACH JOB SUMMARY
Technical Detail/Comments:
MICHAEL SAX
Production Engineer I
970-339-1449—Office
310-613-1637—Cell
I hereby certify all statements made in this form are,to the best of my knowledge,true,correct,and complete.
Signed: Print Name: CHERYL LIGHT
Title: SR.REGULATORY ANALYST Date: 10/3/2013 Email: DJREGULATORY@ANADARKO.COM
Based on the information provided herein,this Well Abandonment Report(Form 6)complies with COGCC Rules and applicable
orders and is hereby approved.
COGCC Approved: HICKEY, MIKE Date: 10/22/2013
CONDITIONS OF APPROVAL,IF ANY: Expiration Date: 4/21/2014
Date Run: 10/22/2013 Doc(#400489982]Well Name:WATTENBERG SWD 1 Page 2 of 3
COA Type Description
1) Provide 24 hour notice of MIRU to Jim Precup at 303 726-3822 or e-mail at
james.precup@state.co.us.
2) For 740' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug—must be
640'or shallower. Leave at
least 100'cement in the casing for each plug.
3)Properly abandon flowlines as per Rule 1103.
Attachment Check List
Att Doc Num Name
400489982 FORM 6 INTENT SUBMITTED
400489992 PROPOSED PLUGGING PROCEDURE
400489993 WELLBORE DIAGRAM
400489994 WELLBORE DIAGRAM
Total Attach:4 Files
General Comments
User Group Comment Comment Date
Permit Note: Per well completion reports and previous WBD,the Lyons is open hole from 10/7/2013
9037-9340 vs. perfs from 9027-9104. 11:13:54 AM]
Total: 1 comment(s)
Date Run: 10/22/2013 Doc(#400489982]Well Name: WATTENBERG SWD 1 Page 3 of 3
Page 1 of 3
Wattenberg SWD 1 (77414)
P&A
1) Call Foreman or Lead Operator at least 24 hr prior to rig move. Request that they remove
plunger, isolate production equipment and remove any automation equipment prior to the rig
showing up. Install perimeter fence as needed.
2) Provide 24 hr notice of MIRU to COGCC as specified on approved Form 6.
3) Notify CDC when rig moves on location to generate workorder for flowline removal and one call
for line locates.
4) Prepare location for base beam rig to move onto.
5) MIRU WO rig. Observe WH pressure, if pressurized,bleed off pressure to a tank. If well does
not stop flowing contact Engineer in Evans for change of procedure.
6) Unseat and LD landing joint. PU w/2-7/8"tbg(6.5#,J-55,8RD EUE)to break any sand bridges.
Do not exceed safety tensile load of 75,000 lbs(75%of upset yield strength).
7) MIRU Wireline. PU jet cutter for 2-7/8"6.5#1-55 8RD EUE tbg. RIH to+/-7,500',cut and POOH.
SB 2-7/8"tbg. RDMO Wireline.
8) PU and RIH scraper for S-1/2"csg(17#, N-80)on 2-7/8"tbg to+/-7,500'.TOOH w/scraper and
SB tbg.
9) PU CIBP for 5-1/2" csg(17#,N-80)on 2-7/8"tbg. TIN and set at+/-7,450'(+/-240 jts). Sting out
of CIBP and pressure test CIBP to 1000 psi for 15 min. Circulate out gas w/water treated w/
biocide for 20 min.
10) MIRU Cement Services.Sting out of CIBP and spot 70 sx of cement Class G w/20%silica flour,
0.4%CD-32,0.4%ASA-301 and R-3 to achieve 2:30 pump time mixed at 15.8 ppg and 1.38
cuft/sk from+/-7,450'to 6,740'.
11) POOH to+/-6,000'and circulate to clean tbg. Let cement set for 4 hrs or overnight.
Page 2 of 3
12) Tag TOC cement w/2-7/8"tbg(estimated at 6,740')and record in Daily Summary.
13) POOH and SB 2-7/8"tbg. PU CIBP for 5-1/2"csg(174, N-80)on 2-7/8"tbg. RIH and set CIBP at
+/-6,600'. Sting out of CIBP and pressure test to 1000 psi for 15 min.
14) Spot 270 sx of cement Class G w/0.4%CD-32,0.4%ASA-301 mixed at 15.8 ppg and 1.15 cuft/sk
from+/-6,600'to+/-4,280'. POOH to+/-3,500'(+/-102 jts) and circulate to clean tbg. Let
cement set for 4 hrs or overnight. Tag TOC w/2-7/8"tbg and record in Daily Summary.
15) TOOH to+/-740' (+/-90 jts)and LD remainder.
16) Spot 25 sx of cement Type III w/CaCl2 as deemed necessary from+/-740'to+/-500'.POOH to
+/-200'(+/- 17 jts) and circulate to clean tbg. Let cement set for 4 hrs or overnight. Tag TOC w/
2-7/8"tbg and record in Daily Summary.
17) POOH and SB 6jts of 2-7/8"tbg,LD remainder.
18) PU CIBP for 5-1/2"csg(174, N-80)on 2-7/8"tbg. RIH and set at 150'. Pressure test CIBP to 1000
psi for 15 min.TOOH and LD 2-7/8"tbg.
19) RDMO WO rig.
20) Wellsite supervisor turn all paper copies of cementing reports/invoices and logs into Sabrina
Frantz.
21) NOTE: During the job,wellsite supervisor should instruct the logging and cementing contractors
to e-mail all logs,job reports/invoices to Sabrina Frantz.
22) Have excavation contractor notify One-Call to clear for digging around wellhead and flowline
removal.
23) MIRU ready cement mixer. Fill the last 150' inside the 5-1/2" prod.casing until 10' below
surface. Use 4,500 psi compressive strength redi-mix cement(Sand and Cement only,no gravel)
to finish filling surface casing to top of cut off.
24) Check top of cement inside 8-5/8"surface casing at least 5'below ground level.
Page 3 of 3
25) Have welder spot weld on steel marker plate. (Note: marker shall be labeled with well name and
number, legal location('/,'/4 description)and API number.
26) Properly abandon flowlines as per rule 1103.
27) Have excavation contractor back fill hole with native material.Clean up location and have
leveled to plant any vegetation required.
28) Submit Form 6 to COGCC. Provide"As Plugged"wellbore diagram identifying the specific
plugging completed.
Existing Cement
Wattenberg SWD 1 New Cement
WINS: 77414 API: 05-123-15621 Fox Hills
Existing Planned sx
NB
Welded Cap CD
TOC 10' { 10' TOC JS
Entrada
12 SX Lyons
Mori
150' CIBP & BOC EiT TOC
25 SX
btm sfcsg & BOC 790'
740' BOC
F H btm
4,280' TOC
SX top 4,480' 270 SX
womasime 6,600' CIBP & BOC
I i
6,740' TOC
NB top 7,141'
70SX
CD top 7,400'
7,450' CIRP & ROC
7,500' Cut 2-7/8" tbg
TOC 7,675' i
2-7/8" to 2-3/8" tbg switch 7,720' L
Liner top & TOC 7,756'
JS top 7,842'
( I
CIBP w/ cement 8,115'
BOC 8,277'
Liner btm & BOC 8,395'
Entrada
Perfs at 8,444' - 8,462'
CIBP w/ cement cap top 8,685'
CIBP w/ cement cap btm 8,707'
Lyons top 9,026
Perfs at 9,029'-9,10
f---
i
;
i
btm pdcn csg & BOC 9,037'
Production Csg: 5-1/2"
Surface Csg: 8-5/8"
Prod Csg Liner 4"
Production Tbg: 2-7/8" & 2-3/8"
Company: US ROCKIES REGION Site: WATTENBERG SWD #1
Project: COLORADO-WELD-NAD83-UTM13 Common Well Name: WATTENBERG SWD #1
API No: 0512315621 Datum: RKB Section: 19 Div of Quarter Section: SW
Latitude: 40. 122086° Elevation: 4,872.0usft Township: 2 N Div of Section: SW
Longitude: -104.828440° Water Depth: 4,862.0usft Range: 66 W
Casing Size Cement Fluid Cement Hole Size MD / PBMD
Casing Information & Weight (sacks) Depths (ft) Schematic (10/3/2013) (in) (usft) Perforation Intervals (usft)
10 (TOC) —r T
SURFACE CASING 8 625in, 2% cacl2. 650 10 (TOC) f 12.250
- Set @ 790.0usft I
790
5.500in..
2700 (TOC)
2700 i
3504 (TOC)
3504 '
PRODUCTION 5.500in, 6100
CASING - Set @ 9, , . 230 6100 (TOG)
037.0usft , , 315
200
595
, , 865
7675 (TOC)
7754 (TOC)
LEAD, 50/50 7994 (TOC)�
POZ-MIX, 12 7994
8277
PROTECTIVE
LINER - Set @ 8. , , 7
395.0usft
5.500in.
4.000in,
10.46ppf 8395 - -
- 7.875 8,444 - 8,462 - ENTRADA
9,029 - 9,041 - LYONS
9037 -
9,059 - 9,071 - LYONS
9,078 - 9,082 - LYONS
9,037 - 9,338 - LYONS
9,087 - 9,092 - LYONS
MD: 9,338
PBMD: 8, 9,095 - 9,104 - LYONS
615
Hello