Loading...
HomeMy WebLinkAbout20141910.tiff kw KerrNtGee Kerr-McGee Oil&Gas OnShore LP A subsidiary of Anadarko Petroleum Corporation m 109918 Street Denver,CO 80202 (720)929-6000 January 9th,2013 Weld County Department of Planning Services Attn: Kim Ogle 1555 N 17th Avenue Greeley,Co 80631 RE: Wattenberg SWD Closure Plan Section 19—T2N—R66W: NW SW W Dear Mr.Ogle: Kerr-McGee Oil&Gas Onshore LP, a wholly owned subsidiary of Anadarko Petroleum Corporation (APC) is proposing to plug and abandon the Wattenberg SWD Well in Weld County. We have provided a closure plan with this document as well as the Form 6 that was submitted to the COGCC. This document outlines the plugging procedures for the well. Should you have any questions or need additional information regarding this matter please do not hesitate to contact me at 720-929-6896. Thank you for your time. RECEIVED Regards, JUN 17 2014 WELD COUNTY COMMISSIONERS Nathan S. Keiser Municipal Planning Analyst /jthrn 2014-1910 �o u..7i '02.3-02O/y PLORn Wattenberg SWD#1 Closure Plan All operations regarding the plugging and abandonment of the Wattenberg SWD#1 well are planned and conducted with safety as the top priority. Under no circumstances will the safety of any person or the environment be compromised during this process. Additionally, all procedures will be in accordance with regulations set by the Environmental Protection Agency(EPA), Colorado Oil and Gas Conservation Commission (COGCC),the Colorado Department of Public Health and Environment(CDPHE),and Weld County. Reclamation All structures including storage tanks,concrete pads, road base and location dirt,will be removed and either disposed of or recycled. Facilities on location will be tested for asbestos. If asbestos is encountered, it will be remediated according to guidelines set for the by the CDPHE. If applicable,a demolition permit will be obtained through the CDPHE and Weld County. Upon the abandonment of the Wattenberg Salt Water Disposal#1 location,Anadarko Petroleum/Kerr- McGee will reclaim the area as soon as practicable,and no later than twelve months per COGCC regulation 1004.a.The location will be planted with a native seed mixture to match the surrounding vegetation.The area will also be stabilized by crimping a certified weed free straw into the soil.The location will be considered successfully reclaimed when the vegetation density surpasses 80%of the pre-disturbance level excluding noxious weeds per COGCC regulation 1004.c.(2).At that time a Form 4 Sundry Notice will be submitted to the COGCC, providing details of the reclamation per regulation 1004.c.(4). In the event that hydrocarbon impacts are discovered during the deconstruction and abandonment of the facility,soil and shallow groundwater(if encountered)assessment activities will be conducted to ensure compliance with the COGCC Rules. In addition, if the potential impacts are deemed to be reportable per COGCC Rules,then the applicable notifications will be provided to the COGCC(and Weld County,as appropriate). FORM State of Colorado CE ET OE ES 6 Oil and Gas Conservation Commission '" > Rev 11201 incoln Sheet.Suite 801.Denver,Colorado 80203 Phone:(303)890-2100 Fax:(303)890-2109 GAS Document Number: 12/05 „GAS WELL ABANDONMENT REPORT 400489982 This form is to be submitted as an Intent to Abandon whenever an abandonment is planned on a borehole. After the abandonment is complete,this form shall again be submitted as a Subsequent Report of the actual work completed.The approved intent shall be valid for six months after the approval date,after that period,a new intent will be required. Attachments required with the Intent to Abandon are wellbore diagrams of the current configuration Date Received: and the proposed configuration with plugs set. A Subsequent Report of Abandonment shall indicate the actual work completed. Attachments required with a Subsequent Report are a wellborn 10/03/2013 diagram srrowing pugs that were set and casing remaring in the hole,the Pb summaries horn WI pugging contractors used,including*reline and cementing(third party verification)and any logs that may have been run during abandomenl. OGCC Operator Number: 47120 Contact Name: CHERYL LIGHT Name of Operator: KERR-MCGEE OIL&GAS ONSHORE LP Phone: (720)929-6461 Address: P O BOX 173779 Fax: (720)929-7461 City: DENVER State: CO Zip: 80217- Email: CHERYL.LIGHT@ANADARKO.COM For"Intent"24 hour notice required, Name: PRECUP,JIM Tel: (303)726-3822 COGCC contact: Email: james.precup@state.co.us API Number 05-123-15621-00 Well Name: WATTENBERG SWD Well Number: 1 Location: QtrQtr: NWSW Section: 19 Township: 2N Range: 66W Meridian: 6 County: WELD Federal,Indian or State Lease Number: Field Name: WATTENBERG Field Number: 90750 R Notice of Intent to Abandon Subsequent Report of Abandonment Only Complete the Following Background Information for Intent to Abandon Latitude: 40.122012 Longitude: -104.828417 GPS Data: Date of Measurement: 10/19/2006 PDOP Reading: 1.8 GPS Instrument Operator's Name: Chris Fisher Reason for Abandonment: Dry Production for Sub-economic Mechanical Problems IK Other Injection is sub-economic Casing to be pulled: Yes r No Estimated Depth: Fish in Hole: Yes r No If yes,explain details below Wellbore has Uncemented Casing leaks: Yes r No If yes,explain details below Details: There is a short casing liner cemented from 8,395'to 7,756'and tubing is also cemented inside of that liner. That tubing also has a bridge plug. For clarity,the 2nd string listed in the Casing History is Tubing that is cemented in. The proposed procedure is to cut the tubing at 7,500'and leave the rest cemented. For questions or further clarification please contact Michael Sax(970-339-1449). Current and Previously Abandoned Zones Formation Perf Too Fed.Btm Abandoned Date Method of Isolation Plua Depth ENTRADA 8444 8462 LYONS 9029 9104 02/02/2004 B PLUG CEMENT TOP Total:2 zone(s) Casing History Date Run:10/22/2013 Doc(9400489982)Well Name:WATTENBERG SWD 1 Page 1 of 3 Casing Type Size of Hole Size of Casing Weight Per Foot Setting Depth Sacks Cement Cement Bot Cement Top Status SURF 12+1/4 8+5/8 24 790 650 790 0 visu 1ST 7+7/8 5+1/2 17 9,037 230 9,037 7,994 VISU 2ND 4+0/1 2+3/8 4.7 8,277 12 8,277 7,675 VISU 1ST LINER 5+1/2 4+0/1 10.46 7,756 7 8,395 7,754 VISU le d s..a.1.:,,, , ...g. r,' s `:it2. Stage Tool 3,504 795 3,504 0 VISU Plugging Procedure for Intent and Subsequent Report CIBP#1:Depth 7450 with 70 sacks cmt on top.CIPB#2: Depth 6600 with 270 sacks cmt on top. CIBP#3:Depth 150 with 12 sacks cmt on top.CIPB#4: Depth with sacks cmt on top. CIBP#5:Depth with sacks cmt on top. NOTE:Two(2)sacks cement required on all CIBPs. Set 25 sks cmt from 740 ft.to 500 ft. Plug Type: CASING Plug Tagged: r Set sks cmt from ft.to ft. Plug Type: Plug Tagged: Set sks cmt from ft.to ft. Plug Type: Plug Tagged: Set sks cmt from ft.to ft. Plug Type: Plug Tagged: Set sks cmt from ft.to ft. Plug Type: Plug Tagged: Perforate and squeeze at ft.with sacks.Leave at least 100 ft.in casing CICR Depth Perforate and squeeze at ft.with sacks.Leave at least 100 ft. in casing CICR Depth Perforate and squeeze at ft.with sacks.Leave at least 100 ft.in casing CICR Depth (Cast Iron Cement Retainer Depth) Set sacks half in. half out surface casing from ft.to ft. Plug Tagged: Set 12 sacks at surface Cut four feet below ground level,weld on plate Above Ground Dry-Hole Marker: Yes r No Set sacks in rat hole Set sacks in mouse hole Additional Plugging Information for Subseauent Report Only Casing Recovered: ft.of inch casing Plugging Date: 'Wireline Contractor. *Cementing Contractor: Type of Cement and Additives Used: Flowline/Pipeline has been abandoned per Rule 1103 Yes No *ATTACH JOB SUMMARY Technical Detail/Comments: MICHAEL SAX Production Engineer I 970-339-1449—Office 310-613-1637—Cell I hereby certify all statements made in this form are,to the best of my knowledge,true,correct,and complete. Signed: Print Name: CHERYL LIGHT Title: SR.REGULATORY ANALYST Date: 10/3/2013 Email: DJREGULATORY@ANADARKO.COM Based on the information provided herein,this Well Abandonment Report(Form 6)complies with COGCC Rules and applicable orders and is hereby approved. COGCC Approved: HICKEY, MIKE Date: 10/22/2013 CONDITIONS OF APPROVAL,IF ANY: Expiration Date: 4/21/2014 Date Run: 10/22/2013 Doc(#400489982]Well Name:WATTENBERG SWD 1 Page 2 of 3 COA Type Description 1) Provide 24 hour notice of MIRU to Jim Precup at 303 726-3822 or e-mail at james.precup@state.co.us. 2) For 740' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug—must be 640'or shallower. Leave at least 100'cement in the casing for each plug. 3)Properly abandon flowlines as per Rule 1103. Attachment Check List Att Doc Num Name 400489982 FORM 6 INTENT SUBMITTED 400489992 PROPOSED PLUGGING PROCEDURE 400489993 WELLBORE DIAGRAM 400489994 WELLBORE DIAGRAM Total Attach:4 Files General Comments User Group Comment Comment Date Permit Note: Per well completion reports and previous WBD,the Lyons is open hole from 10/7/2013 9037-9340 vs. perfs from 9027-9104. 11:13:54 AM] Total: 1 comment(s) Date Run: 10/22/2013 Doc(#400489982]Well Name: WATTENBERG SWD 1 Page 3 of 3 Page 1 of 3 Wattenberg SWD 1 (77414) P&A 1) Call Foreman or Lead Operator at least 24 hr prior to rig move. Request that they remove plunger, isolate production equipment and remove any automation equipment prior to the rig showing up. Install perimeter fence as needed. 2) Provide 24 hr notice of MIRU to COGCC as specified on approved Form 6. 3) Notify CDC when rig moves on location to generate workorder for flowline removal and one call for line locates. 4) Prepare location for base beam rig to move onto. 5) MIRU WO rig. Observe WH pressure, if pressurized,bleed off pressure to a tank. If well does not stop flowing contact Engineer in Evans for change of procedure. 6) Unseat and LD landing joint. PU w/2-7/8"tbg(6.5#,J-55,8RD EUE)to break any sand bridges. Do not exceed safety tensile load of 75,000 lbs(75%of upset yield strength). 7) MIRU Wireline. PU jet cutter for 2-7/8"6.5#1-55 8RD EUE tbg. RIH to+/-7,500',cut and POOH. SB 2-7/8"tbg. RDMO Wireline. 8) PU and RIH scraper for S-1/2"csg(17#, N-80)on 2-7/8"tbg to+/-7,500'.TOOH w/scraper and SB tbg. 9) PU CIBP for 5-1/2" csg(17#,N-80)on 2-7/8"tbg. TIN and set at+/-7,450'(+/-240 jts). Sting out of CIBP and pressure test CIBP to 1000 psi for 15 min. Circulate out gas w/water treated w/ biocide for 20 min. 10) MIRU Cement Services.Sting out of CIBP and spot 70 sx of cement Class G w/20%silica flour, 0.4%CD-32,0.4%ASA-301 and R-3 to achieve 2:30 pump time mixed at 15.8 ppg and 1.38 cuft/sk from+/-7,450'to 6,740'. 11) POOH to+/-6,000'and circulate to clean tbg. Let cement set for 4 hrs or overnight. Page 2 of 3 12) Tag TOC cement w/2-7/8"tbg(estimated at 6,740')and record in Daily Summary. 13) POOH and SB 2-7/8"tbg. PU CIBP for 5-1/2"csg(174, N-80)on 2-7/8"tbg. RIH and set CIBP at +/-6,600'. Sting out of CIBP and pressure test to 1000 psi for 15 min. 14) Spot 270 sx of cement Class G w/0.4%CD-32,0.4%ASA-301 mixed at 15.8 ppg and 1.15 cuft/sk from+/-6,600'to+/-4,280'. POOH to+/-3,500'(+/-102 jts) and circulate to clean tbg. Let cement set for 4 hrs or overnight. Tag TOC w/2-7/8"tbg and record in Daily Summary. 15) TOOH to+/-740' (+/-90 jts)and LD remainder. 16) Spot 25 sx of cement Type III w/CaCl2 as deemed necessary from+/-740'to+/-500'.POOH to +/-200'(+/- 17 jts) and circulate to clean tbg. Let cement set for 4 hrs or overnight. Tag TOC w/ 2-7/8"tbg and record in Daily Summary. 17) POOH and SB 6jts of 2-7/8"tbg,LD remainder. 18) PU CIBP for 5-1/2"csg(174, N-80)on 2-7/8"tbg. RIH and set at 150'. Pressure test CIBP to 1000 psi for 15 min.TOOH and LD 2-7/8"tbg. 19) RDMO WO rig. 20) Wellsite supervisor turn all paper copies of cementing reports/invoices and logs into Sabrina Frantz. 21) NOTE: During the job,wellsite supervisor should instruct the logging and cementing contractors to e-mail all logs,job reports/invoices to Sabrina Frantz. 22) Have excavation contractor notify One-Call to clear for digging around wellhead and flowline removal. 23) MIRU ready cement mixer. Fill the last 150' inside the 5-1/2" prod.casing until 10' below surface. Use 4,500 psi compressive strength redi-mix cement(Sand and Cement only,no gravel) to finish filling surface casing to top of cut off. 24) Check top of cement inside 8-5/8"surface casing at least 5'below ground level. Page 3 of 3 25) Have welder spot weld on steel marker plate. (Note: marker shall be labeled with well name and number, legal location('/,'/4 description)and API number. 26) Properly abandon flowlines as per rule 1103. 27) Have excavation contractor back fill hole with native material.Clean up location and have leveled to plant any vegetation required. 28) Submit Form 6 to COGCC. Provide"As Plugged"wellbore diagram identifying the specific plugging completed. Existing Cement Wattenberg SWD 1 New Cement WINS: 77414 API: 05-123-15621 Fox Hills Existing Planned sx NB Welded Cap CD TOC 10' { 10' TOC JS Entrada 12 SX Lyons Mori 150' CIBP & BOC EiT TOC 25 SX btm sfcsg & BOC 790' 740' BOC F H btm 4,280' TOC SX top 4,480' 270 SX womasime 6,600' CIBP & BOC I i 6,740' TOC NB top 7,141' 70SX CD top 7,400' 7,450' CIRP & ROC 7,500' Cut 2-7/8" tbg TOC 7,675' i 2-7/8" to 2-3/8" tbg switch 7,720' L Liner top & TOC 7,756' JS top 7,842' ( I CIBP w/ cement 8,115' BOC 8,277' Liner btm & BOC 8,395' Entrada Perfs at 8,444' - 8,462' CIBP w/ cement cap top 8,685' CIBP w/ cement cap btm 8,707' Lyons top 9,026 Perfs at 9,029'-9,10 f--- i ; i btm pdcn csg & BOC 9,037' Production Csg: 5-1/2" Surface Csg: 8-5/8" Prod Csg Liner 4" Production Tbg: 2-7/8" & 2-3/8" Company: US ROCKIES REGION Site: WATTENBERG SWD #1 Project: COLORADO-WELD-NAD83-UTM13 Common Well Name: WATTENBERG SWD #1 API No: 0512315621 Datum: RKB Section: 19 Div of Quarter Section: SW Latitude: 40. 122086° Elevation: 4,872.0usft Township: 2 N Div of Section: SW Longitude: -104.828440° Water Depth: 4,862.0usft Range: 66 W Casing Size Cement Fluid Cement Hole Size MD / PBMD Casing Information & Weight (sacks) Depths (ft) Schematic (10/3/2013) (in) (usft) Perforation Intervals (usft) 10 (TOC) —r T SURFACE CASING 8 625in, 2% cacl2. 650 10 (TOC) f 12.250 - Set @ 790.0usft I 790 5.500in.. 2700 (TOC) 2700 i 3504 (TOC) 3504 ' PRODUCTION 5.500in, 6100 CASING - Set @ 9, , . 230 6100 (TOG) 037.0usft , , 315 200 595 , , 865 7675 (TOC) 7754 (TOC) LEAD, 50/50 7994 (TOC)� POZ-MIX, 12 7994 8277 PROTECTIVE LINER - Set @ 8. , , 7 395.0usft 5.500in. 4.000in, 10.46ppf 8395 - - - 7.875 8,444 - 8,462 - ENTRADA 9,029 - 9,041 - LYONS 9037 - 9,059 - 9,071 - LYONS 9,078 - 9,082 - LYONS 9,037 - 9,338 - LYONS 9,087 - 9,092 - LYONS MD: 9,338 PBMD: 8, 9,095 - 9,104 - LYONS 615 Hello