HomeMy WebLinkAbout20153485.tiff Tab 6
Water Supply
Timmerman/Wells Pit USR Application
Wells Trucking LLC
Water Supply
The gravel mine will be located in a remote area of the County that is not served by a potable water
system. The Operator will supply bottled water at the mine site for potable use. Irrigation is
neither required nor proposed for the site. The operator will obtain water for non-potable uses,
such as dust suppression, from an existing well permitted for industrial use (Permit #77932-F)
located adjacent to the mining area.
Colorado Department of Natural Resources Cdorado.9ov I Contact Us
sJ���)��JsrJJ) Divi �inri a1
t!l'. t(qr t- ,c L; :re.v41
Colorado's Well Permit Search
Well Constructed Help Last Refresh:5/12/2015 12:01:38 AM
Receipt: 3662426 Division: 1
Permit#: 77932-F- Water District: 64
Well Name/#: County: WELD
Designated Basin: Management District:
Case Number: 13CW3144
WDID: 6406929- TIMBRO WELL 2-77932-F
[-] Applicant/Owners History
Date Range Applicant/Owner Name Address City/State/Zip
Unknown-Preset TIMMERMAN RONALD C/O KEN KNOX 1625 BROADWAY,SUITE 2200 DENVER,CO 80202-
[-] Location Information
Approved Well Location:
Q40 Q160 Section Township Range PM Footage from Section Lines
SE SW 10 9.0N 59.0W Sixth 487 S 2554 W
Northing(UTM y): 4512561.0 Fasting(UTM x): 587389.0
Location Accuracy: User supplied
Physical Address Subdivision Name
City/State/Zip Filing Block Lot
Parcel ID: Acres in Tract: 960
[-] Permit Details
Date Issued: 02/26/2014 Date Expires: 02/26/2015
Use(s): INDUSTRIAL AquiferALL UNNAMED AQUIFERS
IRRIGATION (s):
Special Use:
Area which may be irrigated:
Maximum annual volume of appropriation:
Statute:
Permit Requirements: Totalizing Flow Meter Geophysical Log Abandonment Report
No No No
Cross Reference Permit Number Receipt Description
Permit(s):
Comments:
[-] Construction/usage Details
Well Construction Date:06/12/2014 Pump Installation Date:12/16/2014
Well Plugged: 1st Beneficial Use:
Elevation Depth Perforated Casing Perforated Casing Static Water Pump
(Top) (Bottom) Level Rate
1630 1250 1590 733 313
Lic# Name Address Phone Number
Driller 1979 WHITLEY,JAMES 2086 E MAIN ST.WOODLAND,CA 95776 530-662-2829
Pump 1197 LANG,ALAN F. PO BOX 27558 SALT LAKE CITY,UT 89127 801-5542919
Installer
[-] Application/Permit History
Pump Installation Report Received 02/02/2015
Pump Installed 12/16/2014
Well Construction Report Received 07/14/2014
Well Constructed 06/12/2014
Permit Issued 02/26/2014
Application Received 11/06/2013
[-] Imaged Documents
Document Name Date Imaged Annotated
Pump Installation&Test 03/11/2015 No
Well Construction&Test 07/18/2014 No
Permit to Construct a Well 06/12/2014 Yes
Original File 03/18/2014 No
5/12/2015
Form No. OFFICE OF THE STATE ENGINEER
GWS-25 COLORADO DIVISION OF WATER RESOURCES
818 Centennial Bldg., 1313 Sherman St.,Denver,Colorado 80203
(303)866-3581 LIC
WELL PERMIT NUMBER 77932 -F
APPLICANT DIV. 1 WD64 DES. BASIN MD
APPROVED WELL LOCATION
WELD COUNTY
SE 1/4 SW 1/4 Section 10
RONALD TIMMERMAN Township 9 N Range 59 W Sixth P.M.
C/O KEN KNOX DISTANCES FROM SECTION LINES
1625 BROADWAY, SUITE 2200 487 Ft. from South Section Line
DENVER, CO 80202- 2554 Ft. from West Section Line
(303)228-4467 UTM COORDINATES(Meters,Zone:13.NAD83)
PERMIT TO CONSTRUCT A WELL (Amended) Easting: 587389 Northing: 4512561
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material Injury to existing water rights. The issuance of this permit does not ensure that
no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief hi a civil court action.
2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2,unless approval of a variance has
been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-90-137(2)on the condition that this well is operated in accordance with the Timbro Ranch Cattle Company,
LLC substitute water supply plan approved by the State Engineer on February 14,2014. This well shall not be operated unless it is included In
a substitute water supply plan approved by the State Engineer or a plan for augmentation approved by the water court. The subject SWSP is
currently valid through January 31,2015,and if not extended or if a court approved plan for augmentation is not in operation,diversion of
ground water from this well must cease immediately.
4) The use of ground water from this well is limited to stock watering,Industrial,oil and gas development and irrigation.
5) The pumping rate of this well shall not exceed 600 GPM.
6) The average annual amount of ground water to be appropriated shall not exceed 300 acre-feet.
7) Production is limited to the Upper Pierre aquifer which is located 895 feet below land surface and extends to a depth of 1,610 feet. Plain
casing must be installed and grouted to prevent the withdrawal of ground water from other aquifers and the movement of ground water
between aquifers.
8) The owner shall mark the well in a conspicuous place with well permit number(s),name of the aquifer,and court case number(s)as
appropriate. The owner shall take necessary means and precautions to preserve these markings.
9) A totalizing flow meter must be installed on this well end maintained in good working order. Permanent records of all diversions must be
maintained by the well owner(recorded at least annually)and submitted to the Division Engineer upon request.
10) This well shall be constructed at least 600 feet from any existing well,completed in the same aquifer,that is not owned by the applicant.
11) This well shall be constructed not more than 200 feet from the location specified on this permit.
12) This well is subject to administration by the Division Engineer In accordance with applicable decrees,statutes,rules,and regulations.
Note:Any well permit Issued pursuant to a nontrbutary determination[CRS 37-90-137(4))requires that the entire length of the hole be
geophysically logged as required by Rule 9 of the Statewide Nontributary Ground Water Rules prior to Installing casing.Therefore,we
recommend that this well be geophysically logged.
Note:This well is known as Timbro Well No.2.
Note:The base of the production interval specified in condition of approval#7 is modified to 1,630 feet to
accomodate a 40-ft sump. 6/12/2014, RT.
•
APPROVED /r ,"
TLK t'f
State Engineer By
,Receipt Na 3662426 DATE ISSUED 02-26-2014 EXPI TI DATE 02-26-2015
Tab 7
Sewage Disposal
Timmerman/Wells Pit USR Application
Wells Trucking LLC
Sewage Disposal
The gravel mine will be located in a remote area of the County that is not served by a wastewater
treatment system. Given the temporary nature of the mining operation, and the plan to restore the
area to its current rangeland,there is no reason to install a septic system. The Operator will provide
portable toilets at the mine site.
Hello