HomeMy WebLinkAbout20150131.tiff PRELIMINARY
GEOTECHNICAL INVESTIGATION
FOR
TRACT A,ARROWHEAD 4TH FILING,
WELD COUNTY,COLORADO
FOR
ELMER LUNDVALL
CDS ENGINEERING CORPORATION
LOVELAND,COLORADO
PROJECT NUMBER
14-6836
JUNE 3,2014
DSC =Engineering Corporation - -
June 3, 2014
Project No. 14-6836
Mr. Elmer Lundvall
PO Box 632
Greeley, CO 80632
Dear Elmer,
Enclosed is the report you requested of the preliminary geotechnical exploration for the
proposed subdivision of Tract A,Arrowhead 4th Filing, Weld County, Colorado.
The site appears to be suitable for the construction of the proposed residences.
If you have any further questions concerning the information in this report,please contact this
office.
Respectfully,
FOR AND ON BEHALF OF
CDS ENGINEERING CORPORATION
ON O
38387
Kevin F. Becker,P.
14,O
i�'/r?r� i E
Enclosures
165 2nd Street S.W. • Loveland, CO 80537 • (970) 667-8010 • Fax (970) 66- .0 7 4 - miwor cds-eng.net
TABLE OF CONTENTS
Pau
Letter of Transmittal i
Table of Contents ii
Scope 1
Site Investigation 1
Site Location and Description 2
Subsurface Conditions 2
Site Development 3
-Overlot Grading 3
-Basement Construction 3
Preliminary Foundation Recommendations 4
Slab Construction 4
Foundation Drain System 5
Conclusions 5
ATTACHMENTS
Location of Test Borings Drawing No. 1
Symbols and Soil Properties Figure No. 1
Log of Borings Figure No. 2
Swell-Consolidation Test Results Figure No. 3
Summary of Test Results Table No. 1
ii
1
SCOPE
This report presents the results of a preliminary geotechnical exploration for the proposed
subdivision of Tract A,Arrowhead 4th Filing,Weld County,Colorado. The buildings are anticipated
to be of typical wood frame construction. Full basement and/or crawlspace construction is
anticipated for these structures.
This exploration was conducted to provide preliminary recommendations pertaining to the
type and depth of foundation system,soil bearing pressures,groundwater conditions,and to identify
any complications that may be encountered during or after construction due to subsurface conditions.
SITE INVESTIGATION
The field investigation performed on March 19, 2014, consisted of drilling, logging, and
sampling two(2)test borings across the 10-acre site. The borings ranged in depth from thirteen(13)
to sixteen (16) feet. The location of the Test Holes is shown on Drawing No. 1.
Boring locations were established by a representative of CDS Engineering Corporation based
on a site plan provided by Wernsman Engineering. Distances from the referenced features were
made by pacing and angles were estimated. Graphical logs of the borings are shown on Figure No.
2. The descriptions of the soils and/or bedrock strata are based, primarily, on visual and tactual
methods which are subject to interpretation.
The test borings were advanced using a truck mounted,four-inch(4")diameter,continuous
flight auger drill rig. Laboratory samples were obtained by driving a two and one-half inch(2%2")
diameter California Barrel Sampler twelve(12) inches(or as shown)into undisturbed soils with a
140-pound hammer falling thirty(30) inches. Bag samples of auger cuttings may have also been
collected.
Laboratory tests performed were - Swell-Consolidation, Natural Moisture, Natural Dry
Densities, and Unconfined Compressive Strengths. All tests were conducted in accordance with
ASTM standards. A Summary of the Swell-Consolidation Test Results is shown on Figure No.3. A
Summary of Test Results is shown on Table No. 1.
2
SITE LOCATION AND DESCRIPTION
The site is located southwest of Greeley,west of 47th Avenue on the south side of 37`h Street,
Weld County,Colorado. The site is generally in a plains region,and vegetation consists primarily of
grasses,trees,and shrubs.The site has slopes in varying directions. No rock outcrops were observed
at this site. An apparent wetlands area runs through the north side of the property.
SUBSURFACE CONDITIONS
Refer to the Log of Borings, Figure No. 2. The subsurface conditions appear uniform
throughout the proposed building site. General descriptions of the soils and/or rock encountered are
as follows:
TOPSOIL—A thin layer of topsoil,approximately six(6)inches,overlies the site. The topsoil
should not be used as foundation bearing material,structural fill,or backfill. It is suggested that
the topsoil be stripped, stockpiled and used for landscaped areas.
CLAY — Clays with slight to moderate amounts of silt, and slight amounts of sand were
encountered in the upper two and one-half(2'/2)to three(3)feet of Test Hole Nos. 1 and 2. The
clays appear to be moist, firm to stiff, and brown. The clays exhibit low swell potential.
SILTSTONE — Siltstone bedrock strata with slight to high amounts of clay and sand were
encountered from beneath the upper soils to the depths explored in Test Hole Nos. 1 and 2. The
competent siltstone exhibits high bearing capacities with low swell potentials detected in our
tests.
Groundwater levels were recorded as the borings were advanced, after completion of the
drilling operations,and twenty-four(24)hours after drilling operations were complete. During our
field exploration groundwater was encountered in each test hole at a depth of ten (10) feet. The
water levels listed above are the stabilized levels of the free groundwater surface at the time of this
exploration and may not properly define yearly groundwater levels.
3
SITE DEVELOPMENT
The preliminary geotechnical concerns which may influence development of this site are the
shallow depth of bedrock. These issues can be mitigated with proper planning,engineering,design
and construction. Other geotechnical issues for the site include site grading, utility construction,
pavement subgrades, and construction of permanent slopes for long term stability and protection
against erosion. These concerns are discussed in the flowing sections.
Due to the preliminary nature of this project,site organization or grading plans have not been
prepared,and therefore are not available for review in conjunction with this subsurface exploration
program. Therefore, recommendations provided here are general and for planning purposes only.
Overlot Grading
Although evidence of fills or underground facilities such as silage pits, septic tanks,
cesspools, basements and utilities were not observed during the field exploration and testing
program,such features could be encountered during construction. If unexpected fill or underground
facilities are encountered, such features should be removed and the excavation thoroughly cleaned
prior to backfill placement and/or construction.
In areas to be filled,the ground surface should be stripped of vegetation,scarified,moisture-
conditioned and compacted to at least 95 percent of the standard Proctor maximum dry density
(ASTM D-698). We anticipate stripping will require minimal cuts of six(6)to twelve(12)inches
for the majority of the site.
The on-site soils can be used as site grading fill provided it is free of vegetation and other
organic materials, trash, rubbish and construction debris. Fill should not contain rocks or lumps
greater than six (6) inches in diameter. Highly plastic and swelling clays and claystone bedrock
strata should not be used or mixed with other soils for fill in areas with structures. Clay fill,if used,
should be placed at a high moisture content to reduce swell potential. The placement and
compaction of site grading fill should be observed and tested by a qualified Soils Engineer.
Basement Construction
Groundwater was encountered in the test holes at a depth of approximately ten (10) feet
below existing ground surface and may rise with long term development and subsequent landscape
4
irrigation. Generally,full basement level construction would be considered feasible at this site. The
relatively shallow groundwater level in these areas may limit foundation depths and the variety of
structure styles which could be offered.
PRELIMINARY FOUNDATION RECOMMENDATIONS
The type of foundation system applicable to each specific building location will depend on
the swell potentials of the upper soils and bedrock strata,the location and type of bedrock strata,the
type and depths of construction, and other factors that may come up at the time of construction.
Drilled pier foundations would be suited where moderately to highly expansive soils and/or bedrock
are encountered within the influence zones of the foundation. The drilled pier foundations could
range in depth from twenty (20)to thirty(30) feet. Spread footings may be an option where some
type of ground modification is utilized. The spread footing foundations may have maximum
allowable bearing pressures ranging from 1500 to 2500 pounds per square foot(dead load plus live
load)and a minimum bearing pressures ranging from 0 to 750 pounds per square foot.Individual,
site specific investigations are recommended to develop criteria for designing the foundations
and floor systems. Based on the information gathered in our limited subsurface exploration and
laboratory testing,it appears that the lots in the planned subdivision will require drilled straight shaft
pier foundations.
SLAB CONSTRUCTION
The type of floor system will depend on the swell potential of the soils,the type of usage and
the owner's tolerance to slab movement. At this site,slabs placed a minimum of three(3)feet above
the bedrock,in our opinion,could be constructed on grade. Slabs placed within three(3)feet of the
bedrock may require alternate methods such as soil replacement or structural floors.
5
FOUNDATION DRAIN SYSTEM
A perimeter drain system shall be installed where below grade floors are constructed. The
type of drain,interior,exterior or both should be determined by a more specific site exploration and
at the time of the excavation observation.
CONCLUSIONS
The data presented in this report were collected to help determine the feasibility of this
project. Recommendations provided are for planning purposes subject to change based on future
testing for site development.
The findings and recommendations of this report have been obtained in accordance with
accepted professional engineering practices in the field of Geotechnical Engineering. However,
standard Geotechnical Engineering practices and related government regulations are subject to
change. The recommendations provided in this report are only valid as of the date of this report. If
the construction is at a later date,we would be glad to review the information presented in this report
with regard to updated governmental requirements or industry standards. There is no other warranty,
either expressed or implied. We do not guarantee the performance of the project in any respect,but
only that our engineering work and judgments rendered meet the standard of care of our profession.
This report applies only to the type of construction anticipated in the area tested. The current
technology is not at a stage where a guarantee of"absolutely no damage"can be assured by design
and construction practices.
I . I ,ia f
,: iiiktti
r;' ;- .. -'r :..0 r.
• rA
, ; •
` tr i Y$, .TAY : o 'r •-• 1'
y7 it r ffi� • 4 ~ �.: ,. 4*i
el ,t8t \
. 1 ..t .. ... .., ..,.. ... .,,
l 1 i_L 7 ..• 3-3 _^3'•••::::••,.
r:i
• f ` . it•�'r Ift c .L.' • '
,�1 1 1 1 .. , i
, F '� a • � ,-i `-A'• :- 1 i . ---y;.44. :••:-..-I,t:i..• - ••••••!,--'' ' •• . _ . • : ,.
•i; T+'�t ~•.•.1t f ry, v� j .fi r�
i.
•4. 1 �.t !E. h r
't•'..1 i!• • . @*1
i:. ••�-
.
,
t. ` At
1 '. .ii�-,•,Y
Aa Ii. �� ka
wt iy� I ..-1,,,-•.l ' •�
„. .a• �.M.a ,.,.. 'sue' P.4,
i w -a f I. yf L i r4. sa
Client: Elmer Lundvall LOCATION OF TEST BORINGS
Tract A, Arrowhead 4th Filing,
Project:
Weld Colorado CDS Engineering
Corporation
Approximate Scale: 1" = 200' 165 2nd St. S.W.
Loveland, CO 80537
Project No. 14-6836 Tele: (970) 667-8010 Dwg. No.: 1
Sy-- bol s & Soil DroDerties
FIGURE NO. 1
-
Fill
Gravel N/12 CALIFORNIA
Sand
/ / Silt
N/12 SPLIT SPOON
Silty Clay
Clay
THIN WALLED (SHELBY)
%, Weathered Bedrock
Siltstone BAG SAMPLE
Claystone
Sandstone
I Limestone PITCHER SAMPLE
r r Igneous & Metamorphic
rr
r r r
Penetration Resistance and Strength Classifications
are Based on The Standard Penetration Test
Number of Blows Relative Density Consistency Approximate
Per foot (N)* Cohesionless Soils Cohesive Soils Cohesion ksf**
0-4 Very Loose Soft Less than 0.5
4-10 Loose Firm 0.5-1.0
10-30 Medium Stiff 1.0-2.0
30-50 Dense Very Stiff 2.0-4.0
50+ Very Dense Hard Greater than 4.0
* BLOWS PER FOOT - BLOWS OF 140 LB.
HAMMER DROPPED 30 IN. TO DRIVE
SPL (IN.)IT
(ASTM DL586I SPOON R6N7)I SAMPLER
** EQUIVALENT TO PP/2 AND Qu/2
CEngineering 165 2nd St. S.W.
D s Lovel d, CO 80537
Corporation Tele: 970) 667-8010
0 0
0 z TH-1 TH-2 m
m 0 FT. - — 0 FT.
m
0
m rn
1- r
10/12 �� 15/12
5FT. 5FT.
50/11 —
48/12
10 FT. .. T- _L 10 FT.
50/0 —
15 FT. Refusal on _ 15 FT.
_— hard strata
20 FL • .. .... 20 FT.
25 FT. 25 FT.
30 FT. -- 30 FT.
35 FT. 35 FT.
CLAY: silty, sl. sandy, moist, firm to Borings drilled 03/19/14 using
�� stiff, brown a 4" diameter, continuous flight
truck mounted drilling rig.
SILTSTONE: wx. to competent, clayey, sl.
sandy, moist, hard, tan/brown to dark brown
= Groundwater CP drilling
= Groundwater on 03/20/14
All soA and/or rock contacts shown on boring logs ore approximate and represent subsurface conditions at time
of drilling. Boring logs and information presented on 1093 are subject to discussion and limitations of this report.
LOG OF BORINGS
CLIENT: Elmer Lundvall CDS Engineering
PROJECT NO. 14-6836 Corporation
PROJECT LOCATION Tract A, Arrowhead 4th Filing, 165
ad o 8x637
Weld County, Colorado Tele: (970)c 667-6010
Fig. No.: 2
SWELL/CONSOLIDATION TEST CURVES
Client: Elmer Lundvall
Project: Tract A,Arrowhead 4th Filing Project No.: 14-6836
Boring: TH-1 Description: Silty Clay
Depth,ft: 2 Water Content: 22.0%
Swell(%):* 0.4 Dry Density,pcf: 94.7 Approximate Swell Pressure,psf: 2400
Pressure,psf
100 1000 10000
6 -
5
4
3
2
d 1
as
O
-2
-3
-5
-6
Boring: TH-2 Description: Clayey Siltstone
Depth,ft: 7 Water Content: 21.1%
Swell(%):* 1.9 Dry Density,pcf: 103.1 Approximate Swell Pressure,psf: 2600
Pressure,psf
100 1000 10000
6
5
4 — - —
3
0
0 1
7 -1
-3
-5 -
-6
*negative values indicate consolidation
GDS Gorporatton Figure 3
r>
co
v
a) O o
.Q To o y � . r
U
a a>
i — ' C ,
a a) Cn ax cv . w.
CI CO
U U
a_
:
.V::.
-V ..,...
m a o
to
d -
•
≥
C to I
N
G pp�•
• V ...
•
ys
H C
U 0 is
• r
W
Et
a
to
r W 8•
O .-1
h
d OO1 co
Q. O `
J
O = O O Z fl
Ca0. 9, u N tp
co us 0
v m
•
U • lID
•;• },.as
r. O ;.a6 O : r m w
.3- ul o N tQ Z ,c,:j. r ':i is d N
3 o N `c•` O .:CV N E 0 CI +�� 1 .
eL 3 C N i4 C1t. . .
PRELIMINARY PERCOLATION TEST RESULTS
AND
SEPTIC SYSTEM RECOMMENDATIONS
FOR
TRACT A,ARROWHEAD 4TH FILING,
WELD COUNTY,COLORADO
FOR
ELMER LUNDVALL
CDS ENGINEERING CORPORATION
LOVELAND,COLORADO
PROJECT NUMBER
14-6836
JUNE 3,2014
C -
Engineering Corporation : ;
June 3,2014
Project No. 14-6836
Mr. Elmer Lundvall
PO Box 632
Greeley, CO 80632
Dear Elmer,
Enclosed is the report you requested of the preliminary percolation test results and septic
system recommendations for the proposed subdivision to be located on Tract A, Arrowhead 4th
Filing, Weld County, Colorado.
The preliminary recommendations provided in this report are in compliance with Weld
County regulations for Individual Sewage Disposal Systems.
If you should have any questions concerning the information in the report,please feel free to
contact this office.
Respectfully,
FOR AND ON BEHALF OF
CDS ENGINEERING CORPORATION
D.9..9. I.G,S(04/ f
/7. ___/ f•• F. BFC•..9
f Y ' •
▪ 38387 .
�
�
Kevin F. Becker, P
.c .
' ff.`s
.YTC
Enclosures
165 7 S.W. (970) 2Fax (9 ( ) 667-80 .:1 v'a,r,� r r_ '( net
�.;�d Sheet ,1, • Loveland. CO 3G5:s7 • 667-8010 ;.. . ) :�; �.; v�-U�+ n
TABLE OF CONTENTS
Em.
Letter of Transmittal i
Table of Contents ii
Scope 1
Site Investigation 1
Site Location and Description 1
Subsoils and Groundwater Conditions 1
Percolation Test Results 2
Septic System Recommendations 2
Conclusions 3
ATTACHMENTS
Location of Test Borings Drawing No. 1
Symbols and Soil Properties Figure No. 1
Log of Borings Figure No. 2
ii
1
SCOPE
This report provides preliminary percolation test results and septic system recommendations
for the proposed subdivision of Tract A,Arrowhead 4th Filing, Weld County, Colorado.
SITE INVESTIGATION
A field investigation, performed on March 19, 2014, consisted of drilling profile holes to
depths of thirteen(13)to sixteen(16)feet and two(2)percolation holes to an average depth of thirty
(30)inches,at each site. Percolation tests were performed on March 20,2014. The Location of the
Test Holes is shown on Drawing No. 1. A Log of Borings is shown on Figure No. 2.
SITE LOCATION AND DESCRIPTION
The site is located southwest of Greeley, west of 47th Avenue, on the south side of 37th
Street, Weld County, Colorado. The site is generally in a plains region, and vegetation consists
primarily of grasses,trees, and shrubs. The site has slopes in varying directions. No rock
outcrops were observed at this site. An apparent wetlands area runs through the north side of the
property.
SUBSOILS AND GROUNDWATER CONDITIONS
Topsoil-A thin layer of topsoil,approximately six(6)inches,overlies the site. The topsoil should
be stockpiled and used as backfill over the absorption field.
CLAY —Clays with slight to moderate amounts of silt,and slight amounts of sand were encountered
in the upper two and one-half(2%)to three(3)feet of Test Hole Nos. 1 and 2. The clays appear to
be moist,firm to stiff, and brown. The clays exhibit low swell potential.
2
SILTSTONE - Siltstone bedrock strata with slight to high amounts of clay and sand were
encountered from beneath the upper soils to the depths explored in Test Hole Nos. 1 and 2. The
competent siltstone exhibits high bearing capacities with low swell potentials detected in our tests.
Groundwater levels were recorded as the borings were advanced, after completion of the
drilling operations, and twenty-four (24) hours after the drilling operations. During our field
explorations groundwater was encountered in the profile holes at a depth of ten (10) feet. The
groundwater table could be expected to fluctuate throughout the year depending on seasonal moisture
variations.
PERCOLATION TEST RESULTS
A total of two (2) percolation tests were conducted at each site, using the Standard Test
Method,as described by the Weld County Health Department. Percolation test holes were presoaked
on March 19, 2014,and the test was performed on March 20, 2014.
The percolation exploration indicates average percolation rates of 100 minutes per inch at site
1; and 132 minutes per inch at Site 2. Due to the slow percolation rates, and shallow bedrock,we
anticipate that engineered septic systems will be required for these conditions. Based on these
conditions,Evapotranspiration absorption or low pressure drip systems would be applicable at these
sites.
SEPTIC SYSTEM RECOMMENDATIONS
The beds should be constructed by a licensed septic system installer,in accordance with the
I.S.D.S.R.for Weld County. An effluent filter could be installed in or after the septic tank and may
provide a longer life for the system. The beds should lie a minimum of ten(10)feet from property
lines, twenty (20) feet from the proposed structure, and one-hundred (100) feet from most water
features,such as ditches and wells. The contractor and/or owner must carefully plan the elevations
of the structures if gravity flow of the wastewater to the septic system is desired. We recommend
3
that the top of the bed or trench be a minimum of one foot below any floor level with gravity sewer
otherwise a pump system may be required.
CONCLUSIONS
These tests are only preliminary for the area tested. The findings and recommendations of
this report have been obtained in accordance with accepted engineering practices in the field of
Geotechnical Engineering. The county health department has final acceptance over these test results
and referenced system. All construction shall be in compliance with the septic system permit.
,e- '-,:.7-'2..y. ' ••',;' . !4•,.•-„ 1,•- , .- •••..„ _....::::;• ..... ...,. r
. • ,,::: ...4,
. •,.,• ,• , ... . ,•,: . . ...,„ : 1.::- ';';=-..,'... .. .0 4 -
. At, .. . .
•
•
N Eit
S the 1 'ti
Y >,1-.„ A
•
y
��"' � till t•I----.
,•( �•���= .r; 1} . ,
_.-/' @ Irk
mo ; 1 r'''''
�. --•c••z.? ' ,...-.- • ':' • - - _ --: -Pl.'s- :•-• 44 li • , fie,
44At ... .- -' t • ...d f1:•.
Client: Elmer Lundvall LOCATION OF TEST BORINGS
Project: Tract A, Arrowhead 4th Filing,
Weld Colorado CDS Engineering
Corporation
Approximate Scale: 1" = 200 165 2nd St. S.W.
Loveland, CO 80537
Project No. 14-6836 Tele: (970) 667-8010 Dwg. No.: 1
Symbols 8c Soil � ro3erties
FIGURE NO. 1
Fill
Gravel I N/12 CALIFORNIA
7. Sand
/ /
/ Silt
i N/12 SPLIT SPOON
i Silty Clay
Clay
THIN WALLED (SHELBY)
Weathered Bedrock
— — Siltstone
—._ BAG SAMPLE
__ Claystone
- Sandstone
{ PITCHER SAMPLE
I Limestone
LJ J
Igneous & Metamorphic
Penetration Resistance and Strength Classifications
are Based on The Standard Penetration Test
Number of Blows Relative Density Consistency Approximate
Per foot (N)* Cohesionless Soils Cohesive Soils Cohesion ksf**
0-4 Very Loose Soft Less than 0.5
4.10 Loose Firm 0.5-1.0
10-30 Medium Stiff 1.0-2.0
30-50 Dense Very Stiff 2.0-4.0
50+ Very Dense Hard Greater than 4.0
* BLOWS PER FOOT - BLOWS OF 140 LB.
HAMMER DROPPED 30 IN. TO DRIVE
SPLIT SPOON OR CALIFORNIA SAMPLER
12" (IN.) (ASTM DL586-67)
** EQUIVALENT TO PP/2 AND Qu/2
Engineering 165 2nd St. S.W.
CDS Loveland. CO 80537
C o rp o r ati o n Tele: {970) 667-6010
m un
o TH-1 TH-2 a
r'1 m a'
OFT. � OFT. as
O 0
A 10/12 15/12
5 FT. — _, • 5 FT.
-- .II 50/11
i 48/12
10 FT. - - - 10 FT.
•
50/0
15 FT. Refusal on 15 FT.
hard strata - -
20 FT. 20 FT.
25 FT. -25 FT.
30 FT. -- 30 FT.
35 FT. ---35 FT.
'/, CLAY: silty, sl. sandy, moist, firm to Borings drilled 03/19/14 using
/ ` stiff, brown a 4" diameter, continuous flight
truck mounted drilling rig.
SILTSTONE: wx. to competent, clayey, sl.
r_-_ sandy, moist, hard, tan/brown to dark brown
= Groundwater 0 drilling
= Groundwater on 03/20/14
All soli and/or rock contacts shown on boring logs ore approximate and represent subsurface conditions of time
of drilling. Boring loos and Information presented on logs are subject to discussion and limitations of this report.
LOG OF BORINGS
CLIENT: Elmer Lundvall CDS Engineering
PROJECT NO. 14-6836 Corporation
PROJECT LOCATION Tract A, Arrowhead 4th Filing, Lovei 2nd S.W.
Weld County, Colorado Tele: (970) 667—8010
Fig. No.: 2
Iimit WERNSMAN
ENGINEERING, INC.
1011 42nd STREET • EVANS, CO 80620
Phone (970) 353-4463 Fax (970) 353-9257
Chris Gathman
Weld County Planning Services
1555 N 17th Avenue
Greeley, CO 80631
RE: Change of Zone and Re-subdivide for Parcel 0959-27-1-07-005
Dear Chris
Elmer Lundvall wishes to request a waiver of the mineral resource statement due to the fact
the parcel contains only 10.2 acres and the lot is adjacent to an existing lake and residences.
Thank you for your consideration.
Sincerely
<-5-:
Eric Wernsman
Hello