Loading...
HomeMy WebLinkAbout20151126.tiff „86, MEMORANDUM ' 1 _ �\ TO: Diana Aungst, Planning Services DATE: 3/3/15 14— 71 FROM: Wayne Howard, P.E., Development Review Engineer couM?? SUBJECT: USR15-0008, Deteinne West Greeley RV Storage The Weld County Department of Planning Services-Engineering has reviewed this proposal. Staff comments made during this phase of the application process may not be all-inclusive, as other issues may arise during the remaining application process. COMMENTS: General Project Information/Location: Project description This project is west of and adjacent to 95`h Ave. and is south of US 34 Business. Parcel number 095712100041. Access is from 95th Ave. Roads: Latest ADT on 95`h Ave was taken on 11/27/13 which counted 224 vpd with 14% trucks. Traffic: The traffic information provided with the submittal states that the site (at build out) will have approx. 175 daily trips for the 700 units. This is based upon the Trip Generation manual with rates for mini storage = to 0.25 of number of units. Distribution is approximately 50% north vs. south with an estimated 14 vph during peak hrs. Access: This project accesses onto the City/Town of Greeley. Contact the City or Town for access requirements. Entrance gates (if applicable) must be set back a minimum of 75 feet from edge of existing right of way (future right of way if classification is other than local) to allow a truck and trailer or RV to pull completely off of the roadway and open the gate. In no case shall any vehicle(s) stopped for gate be allowed to create a safety issue for roadway users. Geologic hazard Area: This area IS NOT in a Geologic Hazard Area. Floodplain: This area IS NOT in a Floodplain. Drainage Study: Detention or Water Quality: Storm Drainage Guidance and related documents (COC, WQCV Calc., WCECC, etc.) for the information described below can be found on the County Website at http://www.co.weld.co.us/Departments/PlanningZoninq/Engineerinq.html. Please contact Department of Planning Services/Development Review Engineering for questions or assistance 970-353-6100. A drainage report shall be completed by a Colorado Registered Professional Engineer and adhere to the drainage related sections of the Weld County Code. The drainage report must include a Certificate of Compliance stamped and signed by the P.E. The Certificate of Compliance can be found on the County website http://www.co.weld.co.us/departments/planningzoning/engineering.html. The drainage report has been submitted for review but will need to have the COC prior to acceptance. The applicants will be required to maintain historic drainage flows and run-off amounts on the property. Grading Permit A Weld County Grading Permit will be required if disturbing more than 1 acre. Contact the Planning Department for more information. A Construction Stormwater Permit is also required with the State for disturbing more than 1 acre. Contact: Colorado Department of Public Health and Environment, Water Quality Control Division, Rik Gay, 303- 692-3575. CONDITIONS OF APPROVAL: Prior to recording the plat: A. County Road 95`" Ave has been annexed by the Town/City (municipality) of Greeley. The municipality has jurisdiction over all accesses within their jurisdiction. Please contact municipality to verify the access permit or for any additional requirement that may be needed to obtain or upgrade the permit. B. A Final Drainage Report and Certificate of Compliance stamped and signed by a Professional Engineer registered in the State of Colorado is required. The map shall be amended to delineate the following: A. Label the approved City/Town of Greeley accesses on the plat with access permit number if applicable. B. Show and label standard tracking control onto publically maintained roadways on the map. C. Show the accepted water quality feature on the map with volume and label as WATER QUALITY FEATURE, NO-BUILD OR STORAGE AREA. D. Show and label the accepted drainage features, drainage flow arrows, turning radii, and parking and circulation on the map. E. Show any proposed gate back a minimum of 75ft from the right of way. Prior to Construction: A. If more than 1 acre is to be disturbed, a Weld County grading permit will be required prior to the start of construction. Contact the Planning Department for application information. Prior to Operation: NA DEVELOPMENT STANDARDS (NOTES ON THE PLAT) 1. Should noxious weeds exist on the property, or become established as a result of the proposed development, the applicant/landowner shall be responsible for controlling the noxious weeds, pursuant to Chapter 15, Articles I and II, of the Weld County Code. 2. The historical flow patterns and runoff amounts will be maintained on the site. 3. Weld County is not responsible for the maintenance of onsite drainage related features. 4. There shall be no tracking from the site onto publically maintained roads. The applicant is responsible for mitigation of any offsite tracking and upgrading and/or maintaining onsite tracking control. MEMORANDUM LI EL TO: Dianna Aungst, Planning Services U2 f oU N T c FROM: Lauren Light, Environmental Health SUBJECT: USR15-0008 DeTienne DATE: March 2, 2015 Environmental Health Services has reviewed this proposal for a Site Specific Development Plan and Use by Special Review Permit for any Use Permitted as a Use By Right, an Accessory Use, or a Use By Special Review in the Commercial or Industrial Zone Districts (Mini-storage and outside RV and boat storage) provided that the property is not a lot in an approved or recorded subdivision plat or lots parts of a map or plan filed prior to adoption of any regulations controlling subdivisions in the A (Agricultural) Zone District The application indicates there may be up to 3 employees located on site in the future. The number of customers per day was not included; however at full build out there will be 725 units. The applicants are not proposing any water or sewer provisions. The following section is from Environmental Health Services, Weld County Department of Public Health & Environment, Septic Policies. 2.2.K Use of portable toilets and bottled water (revised 5/8/12) Purpose: To define when portable toilets and commercially bottled water are allowed. Policy: Portable toilets and bottled water from a commercial source are allowed in the following circumstances: 1. Temporary or seasonal uses that are utilized 6 months or less per year (for example recreational facilities, firework stands, farmers markets ) 2. Gravel mines 3. 10 or less customers or visitors per day and/or one of the following: 4. 2 or less full time (40 hour week) employees located on site 5. 4 or less part time (20 hour week) employees located on site 6. employees or contractors that are on site for less than 2 consecutive hours a day Note: Records of maintenance and proper disposal for portable toilets shall be retained on a quarterly basis and available for review by the Weld County Department of Public Health and Environment. Portable toilets shall be serviced by a cleaner licensed in Weld County and shall contain hand sanitizers. As indicated above, it is the policy of this Department that portable toilets are allowed for 10 or less customers or visitors per day and 2 or less full time (40 hour week) employees located on site. The dust abatement plan states speeds will be reduced to 5 MPH, internal circulation areas will be surfaced with recycled asphalt and water or a chemical treatment will be utilized if necessary. The waste handling plan indicates there will not be any dumpsters located on the parcel. Customers will be required to remove all waste and washing of vehicles will not be allowed. A dump station will not be located on site. We have no objections to the proposal; however, we recommend that the following requirements be incorporated into the permit as development standards: 1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. 2. No permanent disposal of wastes shall be permitted at this site. This is not meant to include those wastes specifically excluded from the definition of a solid waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended. 3. Waste materials shall be handled, stored, and disposed in a manner that controls fugitive dust, fugitive particulate emissions, blowing debris, and other potential nuisance conditions. The applicant shall operate in accordance with the approved Waste Handling Plan, at all times. 4. Fugitive dust and fugitive particulate emissions shall be controlled on this site. The facility shall be operated in accordance with the approved Dust Abatement Plan, at all times. 5. This facility shall adhere to the maximum permissible noise levels allowed in the Non-specified Zone as delineated in Section 14-9-30 of the Weld County Code. 2 6. Adequate drinking, handwashing and toilet facilities shall be provided for employees and patrons of the facility, at all times. Portable toilets and bottled water are acceptable for 10 or less customers or visitors per day and/or 2 or less full time (40 hour week) employees on site. Records of maintenance and proper disposal for portable toilets shall be retained on a quarterly basis and available for review by the Weld County Department of Public Health and Environment. Portable toilets shall be serviced by a cleaner licensed in Weld County and shall contain hand sanitizers. 7. A permanent, adequate water supply shall be provided for drinking and sanitary purposes when the number of customers or visitors per day exceeds 10 and/or there are 3 or more full time (40 hour week) employees on site. 8. Sewage disposal for the facility shall be by septic system when the number of customers or visitors per day exceeds 10 and/or there are 3 or more full time (40 hour week) employees on site. Any septic system located on the property must comply with all provisions of the Weld County Code, pertaining to On—Site Wastewater Treatment Systems. 9. The operation shall comply with all applicable rules and regulations of State and Federal agencies and the Weld County Code. 3 a0E)©Od Windsor-Severnncc, - ire Rescue rRa 100 7th Street Windsor, Colorado 80550 4nd 970-686-2626 �pzRpaEg � 970-686-9623 fax 5 May 2014 RE: RV and Boat Storage Windsor CO 80550 I have reviewed the plans for the above referenced project. The site plan is not acceptable to the Windsor - Severance Fire Rescue and must be submitted with the following comments addressed: 1. The code requires a hydrant within 150 feet of the property and with spacing of 300 feet. The current hydrant is too far away from this property and is on the other side of the railroad tracks. A new hydrant will need to be located on this property in a location approved by Windsor Severance Fire and the water department for that area. 2. Per 2012 International Fire Code,all buildings containing a Group R fire area is required to have a fire sprinkler system installed in them.This means that the home/office is required to be fire sprinklered throughout. 3. Fire lanes need to be a minimum of 20 feet wide and drive aisles need to be a minimum of 24 feet wide 4. B-40 turning template is required to be used for this whole project.Provide a site plan showing this. 5. There is a gate located on this site. If there is no fire department access device located on the gate (i.e. some sort of Knox Box device),then one will need to be installed prior to CO. 6. This site needs two points of access into it. The second point of access can be an emergency access only and does not need to be a public drive thru. If you have any further questions please call me at the above number. Sincerely, er2metter,J' u etr icfeae4v Sandra Friedrichsen Fire Marshal Johnson, Anne From: Sandi Friedrichsen <sfriedrichsen@wsfr.us> Sent: Friday, December 12, 2014 8:32 AM To: Johnson, Anne Subject: RE: December 11 meeting follow-up That looks great, the only thing that would need to changed is that it should state "will require a waiver or variance prior to the issuance of a building permit of any structure at the proposed facility" Other than that it looks good. Please let me know if there is anything else that you need. Sandra Friedrichsen Fire Marshal Windsor Severance Fire Rescue 100 7th Street - Windsor, CO 80550 Main - (970) 686-2626 Email — sfriedrichsen@wsfr.us www.wsfr.us From: Johnson, Anne [mailto:Anne.Johnson@tetratech.com] Sent: Friday, December 12, 2014 6:38 AM To: Sandi Friedrichsen Cc: Doug DeTienne Subject: December 11 meeting follow-up Dear Sandra, Thank you again for your time yesterday. Attached are meeting notes. Let me know if I've overlooked a topic we discussed yesterday. Sincerely, Anne Anne Best Johnson, AICP I Senior Planner Direct+1 720-864-4555 I Cell +1 720-204-0173 I Business +1 303-772-5282 I Fax +1 303-772-7039 Anne.Johnson@tetratech.com Tetra Tech I Complex World, Clear SolutionsrM 1900 S. Sunset St.. Suite 1E. Longmont. CO 80501 I tetratech.com Please consider the environment before printing. Read More. This message. including any attachments, may include privileged, confidential and/or inside information. Any distribution or use of this communication by anyone other than the intended recipient is strictly prohibited and may be unlawful. If you are not the intended recipient. please notify the sender by replying to this message and then delete it from your system. 1 mit TETRA TECH MEMO To: Sandra Friedrichsen, Fire Marshall Cc: Dawn and Doug DeTienne From: Anne Best Johnson Date: December 12, 2014 Subject: West Greeley Self Storage A meeting was held on December 11, 2014 to review the revised USR Plat Map and to discuss how the site can accommodate fire apparatus and mitigate fire hazards. The following represents discussion topics: • The Weld County Fire District Notification Form is not used by the Windsor Severance Fire District. A copy of this memo along with the May 5, 2014 memo will be supplied with the application materials. • Once submitted and after completeness review, a copy of the USR submittal packet will be provided to Marshall Friedeichsen. • A residence and office are not planned at this time. • Fire lanes will be a minimum of 20' wide. • Drive aisles will be a minimum of 24' wide. • Internal roads will be constructed of recycled asphalt. They will be plowed and maintained. The roads will be designed to meet weight standards of the Fire District. • A B-40 ASHTO turning template will be illustrated on the USR Map. • The northernmost access will be an emergency access for the facility. If gated, a Knox Box will be provided to allow District entrance. • The applicants are aware that the current Code requires a hydrant to be located within 150' of the property with spacing of 300'. The Windsor Severance Fire Board has the authority to grant a waiver or variance. It was discussed that the Windsor Severance Fire District will not object to the USR approval process but will require a waiver or variance prior to the issuance of a Certificate of Occupancy on any structure at the proposed facility. The following may illustrate a willingness on the applicant's part to make accommodations to protect the facility: o Buildings require a fire wall every 5,000 square feet. o Increase spacing between aisles. o Separate the RV and Boat storage area by greater than 24' from the storage units. Thank you for your time. Let me know if I've overlooked a discussion point. Tetra Tech 1900 S. Sunset Street, Suite I-E, Longmont, CO 80501 Tel 303-772-5282 Fax 303-772-7039 www.tetratech.com Submit by Email Weld County Referral lir N'Y� February 09, 2015 The Weld County Department of Planning Services has received the following item for review: Applicant: Douglas& Dawn DeTienne, do West Case Number: USR15-0008 Greeley Storage Please Reply By: March 09, 2015 Planner: Diana Aungst Project: A Site Specific Development Plan and Use by Special Review Permit for any Use Permitted as a Use By Right, an Accessory Use, or a Use By Special Review in the Commercial or Industrial Zone Districts (Mini-storage and outside RV & boat storage) provided that the property is not a lot in an approved or recorded subdivision plat or lots parts of a map or plan filed prior to adoption of any regulations controlling subdivisions in the A(Agricultural)Zone District. Location: South of and adjacent to US 34 and west of and adjacent to 95th Ave Parcel Number: 095712100041-R4944707 Legal: PART SE4 SECTION 12, T5N, R67W SUBX14-0024 of the 6th P.M., Weld County, Colorado. The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. nWe have reviewed the request and find that it does/does not comply with our Comprehensive Plan because: We have reviewed the request and find no conflicts with our interests. See attached letter Signature Date Agency • • Weld County Planning Dept. 1555 N 17th Ave,Greeley,CO.80631 (970)353-6100 ext.3540 (970)304-6498 fax Submit by Email Weld County Referral LIM Yr,ovipY ;^ February 09,2015 The Weld County Department of Planning Services has received the following item for review: Applicant: Douglas&Dawn DeTienne,do West Case Number: USR15-0008 Greeley Storage Please Reply By: March 09,2015 Planner: Diana Aungst Project:A Site Specific Development Plan and Use by Special Review Permit for any Use Permitted as a Use By Right, an Accessory Use, or a Use By Special Review in the Commercial or Industrial Zone Districts (Mini-storage and outside RV & boat storage) provided that the property is not a lot in an approved or recorded subdivision plat or lots parts of a map or plan filed prior to adoption of any regulations controlling subdivisions in the A(Agricultural)Zone District. Location: South of and adjacent to US 34 and west of and adjacent to 95th Ave Parcel Number: 095712100041-R4944707 Legal: PART SE4 SECTION 12, T5N, R67W SUBX14-0024 of the 6th P.M.,Weld County, Colorado. The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. 1 We have reviewed the request and find that it does/does not comply with our Comprehensive Plan because: We have reviewed the request and find no conflicts with our interests. See attached letter. Signature /G{/` � Date 3/9/2015 Agency City of Greeley Weld County Planning Dept. 1555 N 17th Ave,Greeley,CO.80631 (970)353-6100 ext.3540 (970)304-6498 fax Project Review Comments Date: 3/93/2015 Greel ey Project Name: WCR 14:15 (USR15-0008) Location: 1005 95th Avenue Reviewed By: Caleb Jackson Phone: (970) 350-9823 Department: Community Development / Planning Submittal: 2/11/2015 Submittal #: 1 Case #: WCR 14:15 All code sections are from the Greeley Development Code and from the City of Greeley Design Criteria and Construction Specifications, Volumes I, II, & III. Sections of the Code or Construction Specifications are shown in brackets as part of the review comments below. For additional information on the City Code or the Design Criteria, see the City of Greeley web site at the following location: Planning: https./will.colocodc.con2/greeleiptll8.hinil Engineering: kitty //greelergov.contserwces/dcsigrt-criteria-and-coastrttction-,specifications General ❑ Advisory. The subject property is located within the City of Greeley's Long Range Expected Growth Area (LREGA). The LREGA is the range in which the community anticipates development occurring within the coming 20+years. Particular care in site design is imperative to increase compatibility with the urbanizing nature of this area. Please see the Development Standards comments below. ❑ Advisory. This site is of particular importance due to its location along both US 34 Business Route(10"' Street) and 95`x' Avenue. Both are categorized as arterial roadways, and 10th Street is an Entry Corridor into the city. Due to their classifications, landscaping should be installed along the frontages to enhance the corridors when sites adjacent to these thoroughfares are developed. Annexation ❑ Advisory. The subject property is eligible for annexation. This site is suitable for joining the City of Greeley and would benefit from receiving municipal services. We encourage the owner to explore the opportunity of petitioning for annexation into the City of Greeley. ❑ Advisory. This property is part of an enclave which is qualified for a city-initiated annexation. General Development Standards ❑ The standard setback for development of this nature in urban areas is twenty-five feet. It is understood that a setback of twenty feet is provided from the required right-of-way. To avoid the establishment of a non-conforming situation in the future, this reduced setback can be remembered through a future Annexation Agreement. Page I of 5 ❑ To minimize airborne dust and the tracking of dirt, mud, and gravel onto public thoroughfares, all drive aisles, including the secondary access, should be paved in asphalt or concrete. Please consider paving the aisle that provides emergency access and entry to the adjacent lot. ❑ Outdoor storage should be completely screened from view of all adjacent roadways and properties. This can be accomplished through the construction of a solid wall or fence or the planting of landscaping of sufficient height and variety to provide year-round screening. ❑ Fences or walls should include variation in appearance at least every 50 feet. This can be achieved by constructing columns or offsetting the angle. ❑ Paved and striped parking should be provided for employees at a rate of 1 space per employee. The parking area should comply with the requirements for disabled parking per federal law. ❑ Although it is proposed that clients remove all trash, it is likely that this site will generate occasional refuse, and trash on the site should be contained. A trash receptacle, sufficient in size to accommodate the trash generated by the use, should be provided on-site in a location which does not impede pedestrian or vehicular circulation or clear vision zone requirements, is not located in front or side setbacks or visible from streets, and is accessible to refuse trucks. Such receptacle or a grouping of receptacles which occupies an area in excess of fifteen square feet should be enclosed on at least three sides by a solid wall or fence six feet in height and by a solid gate no less than five feet in height on the fourth side. The wall or fence and the gate should be architecturally compatible with the buildings which it accompanies using related or similar materials and colors. All trash receptacles should have lids which should be kept closed. Architectural Standards ❑ The facades visible from 95th Avenue, 10th Street, and the property to the west should be architecturally significant and attractive. Where a portion of a building is visible from the adjacent public right-of-way or an adjacent property, the architectural treatment should be extended around the visible portions of the building to the extent that an architecturally finished appearance consistent with these standards is achieved. ❑ The design of buildings should avoid the appearance of a single, large, dominant building mass by using design techniques that include stepping back portions of the building facade, breaking up the mass into smaller elements, and/or using material changes. For building facades or walls which face public rights-of-way or adjacent properties and are in excess of one hundred feet in length as measured horizontally, a minimum of twenty percent of the length of the facade or wall should project or recess at a minimum depth equal to three percent of the length of the facade or wall; or screening of at least fifty percent of the wall area may be provided as an alternative using any required buffering to meet this provision. Page 2 of 5 ❑ Colors should be selected to establish an attractive image and standard of quality for development of this area. Color should not be monotonous or monochromatic. Changes in the building base color should occur at a change of building plane. ❑ Facades visible from 95th Avenue, 10th Street, or the property to the west should be at least seventy-five percent brick, stone, tinted and textured masonry block,precast concrete,wood, or stucco. Metal, including corrugated metal, could be used as an accent material on the primary facade of any building as long as the amount used does not exceed twenty percent of the area of the primary facade, exclusive of the roof, and it is painted to match or complement the building color scheme. ❑ All buildings should feature four of the five architectural elements listed in §18.40.090(10). Landscaping Standards ❑ Advisory. It is understood that the proposed USR does not extend all the way to lot" Street, which is classified as an arterial in the City of Greeley's Comprehensive Transportation Plan and identified as a major entryway into the community in the Entryway Master Plan. When this portion of the site does develop, site planning should take these plans into account. The nature of the future development will determine the exact improvements that should be installed, but will likely include items like a wide, detached bikeway, upgraded landscaping, and decorative fencing. ❑ A landscaped perimeter treatment should be installed along 95th Avenue to beautify the corridor. For every one hundred feet of frontage, the following should be planted: o Five medium shrubs (4-8 feet tall at maturity) o Ten small shrubs (<4 feet tall at maturity) Additionally, street trees should be installed along this frontage at a spacing of 35 feet for shade trees or 25 feet for ornamental trees. The location of this landscaping should be installed outside of, but adjacent to, the required right-of-way to avert the possibility of relocating plantings. ❑ This use should be buffered from adjacent uses of different intensities. The equivalent of a Buffer Yard A should be installed on the western and northern side of this use in anticipation of neighboring development occurring in the future. A standard Buffer Yard A is fifteen feet wide and contains one shade tree, one ornamental tree, and five small shrubs every one hundred linear feet. Page 3 of 5 r. „t 7 Project Review Comments Date: 03/09/2015 Greel ey Project Name: WCR 14:15 (USR15-0008) Location: 1005 95th Avenue Reviewed By: Eva Rojas Phone: (970) 336-4137 Department: Community Development / Engineering Submittal: 2/11/2015 Submittal #: 1 Case #: WCR 14:15 All code sections are from the Greeley Development Code and from the City of Greeley Design Criteria and Construction Specifications, Volumes I, II, & III. Sections of the Code or Construction Specifications are shown in brackets as part of the review comments below. For additional information on the City Code or the Design Criteria, see the City of Greeley web site at the following location: Planning: https/null.colocode.con//greeleiptll8.hrntl Engineering: http /greelergoi..contserwces/dcsisnt-criteria-and-coastrttction-,specifications Provide written responses to the comments below. General ❑ There's discussion in the submittal documents regarding an access permit being issued by Weld County. This portion of 95th Avenue is actually located within the City of Greeley's jurisdiction. The City of Greeley has reviewed the access points and they're acceptable as proposed. City of Greeley design criteria and development standards requires paved ingress and egress. Currently, 95th Avenue consists of recycled asphalt. Because the amount of traffic expected to be generated by the self-storage use is minimal, the City of Greeley would be agreeable to allowing the recycled asphalt to remain in exchange for the dedication of 10' of additional right-of-way along the west side of 95th Avenue. Please provide a letter from the property owner agreeing to dedicate this additional right-of-way. If possible, we'd also like to request that this right-of-way dedication be made a condition of the USR approval. E The existing 5/8"water tap can serve for irrigation for the proposed landscape from its current location as long as it is maintained within the lot lines. Please ensure that any sprinkler system is carefully extended across the entrances and that the appropriate backflow assemblies are installed and tested annually thereafter. The backflow test reports would need to be sent to the City of Greeley at 1100 10th ST, 3rd Floor, Greeley, CO 80631, or faxed to 970-350-9805, or emailed to chrissy.luti(cugreeleygov.com. E The tap will change to outside commercial for billing purposes and will be subject to the annual raw water surcharge. The tap will be given a base annual allotment of 244,000 gallons based on the tap size. Page 4 of 5 ❑ City of Greeley would like to see a stop sign added to the entrance; and if possible a street light added as well to the same location. Pages of 5 Diana Aungst From: Johnson, Anne [Anne.Johnson@tetratech.com] Sent: Thursday, February 12, 2015 4:52 PM To: Sandi Friedrichsen Cc: Doug DeTienne; Diana Aungst Subject: Weld County Referral - USR15-0008 West Greeley Storage Attachments: 14 Emergency Information Plan USR 2 12 15.pdf Dear Sandra, We are in receipt of your referral dated February 11, 2015. The following bullets are in response to your comments: • We have corrected the ambulance listing in the Emergency Action Plan and have attached an updated version for your review. • The internal roads will be maintained to allow all-weather access to the facility. Let me know if you have further questions. Most Sincerely, Anne Anne Best Johnson, AICP I Senior Planner Direct +1 720-864-4555 I Cell +1 720-204-0173 I Business +1 303-772-5282 I Fax+1 303-772-7039 Anne.Johnson(a,tetratech.com Tetra Tech I Complex World, Clear SolutionsTM 1900 S. Sunset St . Suite 1 F Longmont CO 80501 I tetratech.com Please consider the environment before printing. Read More. This message. including any attachments, may include privileged. confidential and/or inside information. Any distribution or use of this communication by anyone other than the intended recipient is strictly prohibited and may be unlawful. If you are not the intended recipient, please notify the sender by replying to this message and then delete it from your system. 1 Hello