Loading...
HomeMy WebLinkAbout20172007COLORADO Department of Public Health & Environment Dedicated to protecting and improving the health and environment of the people of Colorado Weld County - Clerk to the Board 1150 O St PO Box 758 Greeley, CO 80632 June 30, 2017 Dear Sir or Madam: RECEIVED JUL Q62017 WELD COUNTY COMMISSIONERS On July 6, 2017, the Air Pollution Control Division will begin a 30 -day public notice period for Kerr- McGee Oil and Gas Onshore LP - 34003106. A copy of this public notice and the public comment packet are enclosed. Thank you for assisting the Division by posting a copy of this public comment packet in your office. Public copies of these documents are required by Colorado Air Quality Control Commission regulations. The packet must be available for public inspection for a period of thirty (30) days from the beginning of the public notice period. Please send any comment regarding this public notice to the address below. Colorado Dept. of Public Health ft Environment APCD-SS-B1 4300 Cherry Creek Drive South Denver, Colorado 80246-1530 Attention: Clara Gonzales Regards, Clara Gonzales Public Notice Coordinator Stationary Sources Program Air Pollution Control Division Enclosure 4300 Cherry Creek Drive S., Denver, CO 80246-1530 P 303-692-2000 www.cotorado.gov/cdphe John W. Hickenlooper, Governor P "-7/ICS/( 7 Larry Wolk, MD, MSPH, Executive Director and Chief Medical Officer cc 1-i L C TT / Pe)), PLC mty / -rp), Pu)C£R/CH/c?m/CK) ?/Co/f7 2017-2007 Air Pollution Control Division Notice of a Proposed Project or Activity Warranting Public Comment Website Title: Kerr-McGee Oil and Gas Onshore LP - 34003106 - Weld County Notice Period Begins: July 6, 2017 Notice is hereby given that an application for a proposed project or activity has been submitted to the Colorado Air Pollution Control Division for the following source of air pollution: Applicant: Kerr-McGee Oil and Gas Onshore LP Facility: 34003106 Oil Et Gas Well Production Facility SENW Section 26 T2N R66W Weld County The proposed project or activity is as follows: This project permits the operation of a two (2) vapor recovery tower emission points at a well production facility. Other (separately permitted) equipment at this facility are condensate storage tanks, produced water storage tanks, and liquid loadout to trucks. The Division has determined that this permitting action is subject to public comment per Colorado Regulation No. 3, Part B, Section III.C due to the following reason(s): • permitted emissions exceed public notice threshold values in Regulation No. 3, Part B, Section III.C.1.a (25 tpy in a non -attainment area and/or 50 tpy in an attainment area) • the source is requesting a federally enforceable limit on the potential to emit in order to avoid other requirements The Division has made a preliminary determination of approval of the application. A copy of the application, the Division's analysis, and a draft of Construction Permits 15WE0909 and 15WE0910 have been filed with the Weld County Clerk's office. A copy of the draft permits and the Division's analyses are available on the Division's website at https://www.colorado.gov/pacific/cdphe/air- permit-public-notices The Division hereby solicits submission of public comment from any interested person concerning the ability of the proposed project or activity to comply with the applicable standards and regulations of the Commission. The Division will receive and consider written public comments for thirty calendar days after the date of this Notice. Any such comment must be submitted in writing to the following addressee: Andy Gruel Colorado Department of Public Health and Environment 4300 Cherry Creek Drive South, APCD-SS-B1 Denver, Colorado 80246-1530 cdphe.commentsapcd@state.co.us COLORADO 1 I•�:. Colorado Air Permitting Project Project Details Review Engineer: Package If: Received Date: Review Start Date: Section 01- Facility Information Andy Gruel: 332025, 5/27/2015 5/23/2017 application was delayed at login Company Name: Kerr-McGee Oil and Gas Onshore LP County AIRS ID: 123 Plant AIRS ID: 4602 Facility Name: 34003106 Physical Address/Location: Type of Facility: What industry segment? Is this facility located in a NAAQS non -attainment area? If yes, for what pollutant? DCarbon Monoxide (CO) Section 02 - Emissions Units In Permit Application Weld Quadrant Section Township Range SENW 26 2N', 66 SENW quadrant of Section 26, Township 2N, Range 66W, in Weld County, Colorado Exploration & Production Weil Pad Oil & Natural Gas Production & Processing Yes Particulate Matter (PM) [)ozone (NOx & VOC) AIRS Point It Emissions Source Type Equipment Name Emissions Control? Permit tt Issuance It Self Cert Required? Action Engineering Remarks 008 Vapor Recovery Tower {VRT) VRT-01 Yes 1 15WEO9O9 1 Yes. Permit Initial .. Issuance 009 Vapor, Recovery Tower {VRT)' VRT-02 Yes 15WEO91O 1 Yes'"' Permit Initial, Issuance Section 03 - Description of Project Applicant seeks a permit for venting/flaring of VRT vapors when VRU is not functioning. Section 04 - Public Comment Requirements Is Public Comment Required? If yes, why? R Section 05 - Ambient Air Impact Analysis Requirements Was a quantitative modeling analysis required? No' If yes, for what pollutants? If yes, attach a copy of Technical Services Unit modeling results summary. Section 06 - Facility -Wide Stationary Source Classification Is this stationary source a true minor? Is this stationary source a synthetic minor? If yes, indicate programs and which pollutants: Prevention of Significant Deterioration (PSD) Title V Operating Permits (OP) Non -Attainment New Source Review (NANSR) No Yes SO2 NOx CO VOC PM2.5 PM10 TSP HAPs ❑ ❑ ❑ 0 0 0 ❑ ❑ ❑ LI ❑ ❑ ❑ o 0 2 Is this stationary source a major source? No If yes, explain what programs and which pollutants here: SO2 NOx CO VOC PM2.5 PM1O TSP HAPs Prevention of Significant Deterioration (PSD) ❑ ❑ 0 0 0 0 Title V Operating Permits (OP) 0000 ❑ ❑ ❑ ❑ Non -Attainment New Source Review (NANSR) ❑ ❑ Venting from vapor recovery tower (VRT) 008 are controlled by enclosed combustors. 123-4602-008 15WE0909 Equipment Description This source vents natural gas from: Emissions from this source are: vapor recovery tower routed to a flare en vapor recovery unit (VRU} is not available. Vented vapors Natural gas venting from vapor recovery tower. Emissions from this source are routed to a flare. Calculations Emission Calculation Method During normal operation of the facility, the VRT gas is routed to a vapor recovery unit which compresses the gas and sends it to the sales gas gathering pipeline. This VRT emissions point represents emissions during the times when gas is directed from the VRT to a group of enclosed combustors. VRT emissions are calculated based on facility liquid throughput, an emission factor developed through E&P Tank v2.0, and measuring the time that VRT gas is directed to the enclosed combustors Applicant collected pressurized liquid samples (at separator pressure 10 psi higher than normal operating pressure to be conservative) and used an arithmetic mean of the pressurized liquid samples as input to E&P Tank v2.0. Applicant also samples the stabilized liquid to determine API gravity and RVP. Total facility condensate throughput Applicant's estimated % of time the VRT will vent to flare (VRU downtime) Calculated condensate throughput during VRU downtime 420000-. bbl/yr 20% 84000 bbl/yr E&P Tank modeled emission factors, based on arithmetic mean of samples: VOC 16.489? lb/bbl Benzene Toluene Ethylbenzene Xylenes n -Hexane 224-TMP NOx and CO emission factors, based on March 2005 CDPHE memo: NOx CO Overall Control at enclosed combustors: Emissions Summary Table Pollutant Uncontrolled Emission Factor Controlled Emission Factor Uncontrolled Emissions Controlled Emissions Source VOC 16.4880 lb/bbl 0.8244 lb/bbl 692.50 tpy 34.62 tpy Gas Analysis N0x 0.061 lb/bbl 0.061 lb/bbl 2.56 tpy 2.56 tpy CDPHE 2005 CO 0.155 lb/bbl 0.155 lb/bbl 6.51 tpy 6.51 tpy CDPHE 2005 Benzene 0.089 lb/bbl 0.0045 lb/bbl 7476 lb/yr 374 lb/yr Gas Analysis Toluene 0.160 lb/bbl 0.0080 lb/bbl 13440 lb/yr 672 lb/yr Gas Analysis Ethylbenzene 0.0390 lb/bbl 0.0020 lb/bbl 3276 lb/yr 164 lb/yr Gas Analysis Xylenes 0.1075 lb/bbl 0.0054 Ib/bbl 9030 lb/yr 452 lb/yr Gas Analysis n -Hexane 0.4195 lb/bbl 0.0210 lb/bbl 35238 lb/yr 1762 lb/yr Gas Analysis 2,2,4-TMP 0.091 lb/bbl 0.0046 Ib/bbl 7644 lb/yr 382 lb/yr Gas Analysis 0.089 lb/bbl 0.1600'. lb/bbl 0.039. lb/bbl 0.1075': lb/bbl 0.4195. lb/bbl 0.091 lb/bbl 0.0037 lb NOx / lb VOC 0.0094 lb CO / lb VOC 95% Regulatory Applicability AQCC Regulation 1 This source is subject to the opacity requirements for flares in Section II.A.5:'No owner or operator of a smokeless flare or other flare for the combustion of waste gases shall allow or cause emissions into the atmosphere of any air pollutant which is in excess of 30% opacity.' AQCC Regulation 2 Section I.A applies to all emission sources. "No person, wherever located, shall cause or allow the emission of odorous air contaminants from any single source such as to result in detectable odors which are measured in excess of the following limits: For areas used predominantly for residential or commercial purposes it is a violation if odors are detected after the odorous air has been diluted with seven (7) or more volumes of odor free air." AQCC Regulation No. 7 Section XVII.G NOT subject to R7.XVII.G because wells had first production in June 2014 (prior to Aug 2014), and no new wells constructed or recompleted after Aug 2014. SCC CODING SCC Code: 31000205 Emission Factors for Permit: Uncontrolled (lb/bbl) NOx 0.061 Controlled (lb/bbl) Control Eff. 0.061 0% .155 0.155 0% Benzene 0.089 0.0045 95% Ethylbenzene 0.0390 0.0020 95% Xylenes 0.1075 0.0054 95% n -Hexane.____._....._.__ 0.4195 .__._.._.._._._.....__.�__.__._ 0.0210 95% 2,2,4-TMP 0.091 0.0046 95% 15WE0909.CP1.xlsx Colorado Air Permitting Project Project Details Review Engineer: Package #: Received Date: Review Start Date: Section 01- Facility Information Company Name: County AIRS ID: Plant AIRS ID: Facility Name: Physical Address/Location: Type of Facility: What industry segment? Is this facility located in a NAAQS non -attainment area? Yes If yes, for what pollutant? EJarbon Monoxide (CO) [Particulate Matter (PM) Andy Gruel 332025 5/27/2015 5/23/2017 application was delayed at login Kerr-McGee Oil and Gas Onshore LP 123 4602 34003106 SENW quadrant of Section 26, Township 2N, Range 66W, in Weld County, Colorado Exploration& Production Weil Pad Oil & Natural Gas Production & Processing Weld Quadrant Section Township Range Section 02 - Emissions Units In Permit Application SENW LIDzone (NOx & VOC) 2N 66..... AIRS Point It 008 009 Emissions Source Type Equipment Name Emissions Control? Permit # Issuance # Self Cert Required? Action Engineering Remarks VRT-01 Yes` 15WE0909 1 Yes Permit initial ttatiCCIAi Perrx.it lniti it Issuance VRT-02 15WE0910 Ye Section 03 - Description of Project Applicant seeks a permit for venting/flaring of VRT vapors when VRU is not functioning. Section 04 - Public Comment Requirements Is Public Comment Required? Yes If yes, why? Requesting Synthetic Minor Perm Section 05 - Ambient Air Impact Analysis Requirements Was a quantitative modeling analysis required? No' If yes, for what pollutants? If yes, attach a copy of Technical Services Unit modeling results summary. Section 06 - Facility -Wide Stationary Source Classification Is this stationary source a true minor? Is this stationary source a synthetic minor? If yes, indicate programs and which pollutants: Prevention of Significant Deterioration (PSD) Title V Operating Permits (OP) Non -Attainment New Source Review (NANSR) No Yes SO2 NOx CO VOC PM2.5 PM10 TSP HAPs ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ❑ o ❑ LI Is this stationary source a major source? No If yes, explain what programs and which pollutants here: SO2 NOx CO VOC PM2.5 PM10 TSP HAPs Prevention of Significant Deterioration (PSD) ❑ ❑ ❑ ❑ ❑ ❑ Title V Operating Permits (OP) ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Non -Attainment New Source Review (NANSR) 0 0 123-4602-009 15WE0910 E0910 Venting from vapor recovery tower (VRT); when vapor recovery and (VRU) is not available.. Vented vapors are controlled by enclosed: combustors. Equipment Description This source vents natural gas from: Emissions from this source are: vapor recovery tower routed to a flare Natural gas venting from vapor recovery tower. Emissions from this source are routed to a flare. Calculations Emission Calculation Method During normal operation of the facility, the VRT gas is routed to a vapor recovery unit which compresses the gas and sends it to the sales gas gathering pipeline. This VRT emissions point represents emissions during the times when gas is directed from the VRT to a group of enclosed combustors. VRT emissions are calculated based on facility liquid throughput, an emission factor developed through E&P Tank v2.0, and measuring the time that VRT gas is directed to the enclosed combustors Applicant collected pressurized liquid samples (at separator pressure 10 psi higher than normal operating pressure to be conservative) and used an arithmetic mean of the pressurized liquid samples as input to E&P Tank v2.0. Applicant also samples the stabilized liquid to determine API gravity and RVP. Total facility condensate throughput Applicant's estimated % of time the VRT will vent to flare (VRU downtime) Calculated condensate throughput during VRU downtime E&P Tank modeled emission factors, based on arithmetic mean of samples: VOC 16.468: Ib/bbl Benzene 0.089 lb/bbl Toluene 0.1600 lb/bbl Ethylbenzene 0.039 lb/bbl Xylenes ? 0.1075'. lb/bbl n -Hexane 0.4195'. Ib/bbl 224-TMP 0.0911. lb/bbl NOx and CO emission factors, based on March 2005 CDPHE memo: NOx CO Overall Control at enclosed combustors: 38500 bbl/yr 30% 11550 bbl/yr 0.0037 lb NOx / lb VOC 0.0094 lb CO / lb VOC 95% Pollutant Uncontrolled Emission Factor Controlled Emission Factor Uncontrolled Emissions Controlled Emissions Source VOC 16.4880 lb/bbl 0.824416/bbl 95.22 tpy 4.76 tpy Gas Analysis NOx 0.061 lb/bbl 0.061 lb/bbl 0.35 tpy 0.35 tpy CDPHE 2005 CO 0.155 lb/bbl 0.155 lb/bbl 0.90 tpy 0.90 tpy CDPHE 2005 Benzene 0.089 lb/bbl 0.0045 lb/bbl 1028 lb/yr 51 lb/yr Gas Analysis Toluene 0.160 lb/bbl 0.0080 lb/bbl 1848 lb/yr 92 lb/yr Gas Analysis Ethylbenzene 0.0390 lb/bbl 0.0020 lb/bbl 450 lb/yr 23 lb/yr Gas Analysis Xylenes 0.1075 lb/bbl 0.0054 lb/bbl 1242 lb/yr 62 lb/yr Gas Analysis n -Hexane 0.4195 lb/bbl 0.0210 lb/bbl 4845 lb/yr 242 lb/yr Gas Analysis 2,2,4-TMP 0.091 Ib/bbl 0.0046 Ib/bbl 1051 lb/yr 53 lb/yr Gas Analysis Regulatory Applicability AQCC Regulation 1 This source is subject to the opacity requirements for flares in Section II.A.5:'No owner or operator of a smokeless flare or other flare for the combustion of waste gases shall allow or cause emissions into the atmosphere of any air pollutant which is in excess of 30% opacity.' AQCC Regulation 2 Section I.A applies to all emission sources. "No person, wherever located, shall cause or allow the emission of odorous air contaminants from any single source such as to result in detectable odors which are measured in excess of the following limits: For areas used predominantly for residential or commercial purposes it is a violation if odors are detected after the odorous air has been diluted with seven (7) or more volumes of odor free air." AQCC Regulation No. 7 Section XVII.G NOT subject to R7.XVII.G because wells had first production in June 2014 (prior to Aug 2014), and no new wells constructed or recompleted after Aug 2014. SCC CODING SCC Code: 31000205 Emission Factors for Permit: Uncontrolled (lb/bbl) NOx 0.061 CO _ 0.155 VOC 16.4880 Benzene 0.089 Toluene 0.160 0.0080 Etbenzene 0.0390 0.0020 95% X_ylenes ..__ 0.1075 0.0054 95% n -Hexane 0.4195 0.0210 95% 2,2,4-TMP 0.091 0.0046 95% Controlled (lb/bbl) Control Eff. 0.061 --'--- 0% 0.155 0% 0.8244 95% • 0.0045 95% 95% 15WE0909.CP1.xlsx Permit number: Date issued: Issued to: Co Air Po Depart CONSTRUCTION PERMIT 15WE0909 Facility Name: Plant AIRS ID: Physical Location: County: General Description: Issuance: 1 Kerr-McGee Oil and Gas Onshore LP 34003106 123/4602 SENW Section 26 T2N R66W Weld County Well Production Facility Equipment or activity subject to this permit: Facility Equipment ID AIRS Point Equipment Description Emissions Control Description VRT-01 008 One (1) vapor recovery tower (VRT) that processes liquid from the second stage of separation to create a third stage of liquid/gas separation. Overhead flash gas from the VRT collected by vapor recovery units (VRUs) in a closed -loop process. When the VRUs are unable to capture the entire overhead gas stream, flash gas is routed to enclosed combustors. Emissions from this point are a function of liquids throughput while overhead gas is routed to the enclosed combustors, and permit limits are based on gas routed to the enclosed combustors 20% of the time. Enclosed Combustors This permit is granted subject to all rules and regulations of the Colorado Air Quality Control Commission and the Colorado Air Pollution Prevention and Control Act (C.R.S. 25-7-101 et seq), to this specific general terms and conditions included in this document and the following specific terms and conditions. REQUIREMENTS TO SELF -CERTIFY FOR FINAL AUTHORIZATION 1. YOU MUST notify the Air Pollution Control Division (the Division) no later than fifteen days of the latter of commencement of operation or issuance of this permit, by submitting a Notice of Startup form to the Division for the equipment covered by this permit. The Notice of Startup COLORADO Air Pollution Control Division Page 1 of 7 form may be download e a w3 orad .• •v/.. ific/cdphe/other-air-permitting- notices. Failure to notif i .f s of - per ted source is a violation of Air Quality Control Commis •C - n 3, Pa Section III.G.1. and can result in the revocation of the permit. 2. Within one hundred and eighty days (180) of the latter of commencement of operation or issuance of this permit, compliance with the conditions contained in this permit shall be demonstrated to the Division. It is the owner or operator's responsibility to self -certify compliance with the conditions. Failure to demonstrate compliance within 180 days may result in revocation of the permit. A self certification form and guidance on how to self -certify compliance as required by this permit may be obtained online at www.colorado.gov/pacific/cdphe/air-permit-self-certification. (Regulation Number 3, Part B, Section III.G.2.) 3. This permit shall expire if the owner or operator of the source for which this permit was issued: (i) does not commence construction/modification or operation of this source within 18 months after either, the date of issuance of this construction permit or the date on which such construction or activity was scheduled to commence as set forth in the permit application associated with this permit; (ii) discontinues construction for a period of eighteen months or more; (iii) does not complete construction within a reasonable time of the estimated completion date. The Division may grant extensions of the deadline. (Regulation Number 3, Part B, Section III.F.4.) 4. The operator shall complete all initial compliance testing and sampling as required in this permit and submit the results to the Division as part of the self -certification process. (Regulation Number 3, Part B, Section III.E.) 5. The operator shall retain the permit final authorization letter issued by the Division, after completion of self -certification, with the most current construction permit. This construction permit alone does not provide final authority for the operation of this source. EMISSION LIMITATIONS AND RECORDS 6. Emissions of air pollutants shall not exceed the following limitations. (Regulation Number 3, Part B, Section II.A.4. ) Annual Limits: Facility Equipment ID AIRS Point Tons per Year Emission Type PM2.5 NO. VOC CO VRT-01 008 --- 2.6 34.7 6.6 Point Note: See "Notes to Permit Holder" for information on emission factors and methods used to calculate limits. Facility -wide emissions of each individual hazardous air pollutant shall not exceed 8.0 tons per year. Facility -wide emissions of total hazardous air pollutants shall not exceed 20.0 tons per year. The facility -wide emissions limitation for hazardous air pollutants shall apply to all permitted emission units at this facility. Compliance with the annual limits, for both criteria and hazardous air pollutants, shall be determined on a rolling twelve (12) month total. By the end of each month a new twelve month total is calculated based on the previous twelve months' data. The permit holder shall calculate actual emissions each month and keep a compliance record on site or at a local field office with site responsibility for Division review. COLORADO Air Pollution Control Division Page 2 of 7 7. The emission points in t control equipment as lis established in this perm maintained with the emissions ess than or equal to the limits , Sect III.E.) E. ) Facility Equipment ID AIRS Point Control Device Pollutants Controlled VRT-01 008 Emissions from the vapor recovery tower are routed to enclosed combustors (Make: Cimarron, model: 48" HVECD) when Vapor Recovery Unit (VRU) is unable to recover all vapors. VOC and HAP PROCESS LIMITATIONS AND RECORDS 8. This source shall be limited to the following maximum processing rates as listed below. Monthly records of the actual processing rates shall be maintained by the owner or operator and made available to the Division for inspection upon request. (Regulation Number 3, Part B, II.A.4.) Process Limits Facility Equipment ID AIRS Point Process Parameter Annual Limit VRT-01 008 Liquids Throughput through VRT while gas is routed from VRT to enclosed combustors 84,000 bbl/yr Compliance with the annual throughput limits shall be determined on a rolling twelve (12) month total. By the end of each month a new twelve-month total is calculated based on the previous twelve months' data. The permit holder shall calculate throughput each month and keep a compliance record on site or at a local field office with site responsibility, for Division review. 9. The owner or operator shall use VRT liquids throughput records, calculation methods detailed in the OEtM Plan, and the emission factors established in the Notes to Permit Holder to demonstrate compliance with the process and emissions limits specified in this permit. STATE AND FEDERAL REGULATORY REQUIREMENTS 10. The permit number and ten digit AIRS ID number assigned by the Division (i.e., 123/4602/008) shall be marked on the subject equipment for ease of identification. (Regulation Number 3, Part B, Section III.E.) (State only enforceable) 11. No owner or operator of a smokeless flare or other flare for the combustion of waste gases shall allow or cause emissions into the atmosphere of any air pollutant which is in excess of 30% opacity for a period or periods aggregating more than six minutes in any sixty consecutive minutes. (Regulation Number 1, Section II.A.5.) 12. This source is subject to the odor requirements of Regulation Number 2. (State only enforceable) OPERATING Et MAINTENANCE REQUIREMENTS 13. Upon startup of this point, the owner or operator shall follow the most recent operating and maintenance (OEtM) plan and record keeping format approved by the Division, in order to demonstrate compliance on an ongoing basis with the requirements of this permit. Revisions to the OEtM plan are subject to Division approval prior to implementation. (Regulation Number 3, Part B, Section III.G.7.) COMPLIANCE TESTING AND SAMPLING COLORADO Air Pollution Control Division Page 3 of 7 Initial Testing Requirem 14. The owner or operator opacity standards, using EPA Reference Method 9, 4. .R. Parr 60, ppen ix , o measure opacity from the flare. The observation period shall be 1 hour in duration. (Regulation Number -1, Section II.A.5) Periodic Testing Requirements 15. This source is not required to conduct periodic testing, unless otherwise directed by the Division or other state or federal requirement. ADDITIONAL REQUIREMENTS 16. A revised Air Pollutant Emission Notice (APEN) shall be filed: (Regulation Number 3, Part A, II.C.) • Annually by April 30th whenever a significant increase in emissions occurs as follows: For any criteria pollutant: For sources emitting less than 100 tons per year, a change in actual emissions of five (5) tons per year or more, above the level reported on the last APEN; or For volatile organic compounds (VOC) and nitrogen oxides sources (NO.) in ozone nonattainment areas emitting less than 100 tons of VOC or NO), per year, a change in annual actual emissions of one (1) ton per year or more or five percent, whichever is greater, above the level reported on the last APEN; or For sources emitting 100 tons per year or more, a change in actual emissions of five percent or 50 tons per year or more, whichever is less, above the level reported on the last APEN submitted; or For any non -criteria reportable pollutant: If the emissions increase by 50% or five (5) tons per year, whichever is less, above the level reported on the last APEN submitted to the Division. • Whenever there is a change in the owner or operator of any facility, process, or activity; or • Whenever new control equipment is installed, or whenever a different type of control equipment replaces an existing type of control equipment; or • Whenever a permit limitation must be modified; or • No later than 30 days before the existing APEN expires. 17. Federal regulatory program requirements (i.e. PSD, NANSR) shall apply to this source at any such time that this source becomes major solely by virtue of a relaxation in any permit condition. Any relaxation that increases the potential to emit above the applicable Federal program threshold will require a full review of the source as though construction had not yet commenced on the source. The source shall not exceed the Federal program threshold until a permit is granted. (Regulation Number 3, Parts C and D). GENERAL TERMS AND CONDITIONS 18. This permit and any attachments must be retained and made available for inspection upon request. The permit may be reissued to a new owner by the APCD as provided in AQCC Regulation Number 3, Part B, Section II.B. upon a request for transfer of ownership and the submittal of a revised APEN and the required fee. 19. If this permit specifically states that final authorization has been granted, then the remainder of this condition is not applicable. Otherwise, the issuance of this construction permit does not provide "final' authority for this activity or operation of this source. Final authorization of the COLORADO Air Pollution Control Division Page 4 of 7 permit must be secured e P in ng i a cord ce with the provisions of 25-7- 114.5(12)(a) C.R.S. and g a 'n N . 3, a t B, ction III.G. Final authorization cannot be granted until - -ra . - o - - it nce has been verified by the APCD as conforming in all respects with the conditions of the permit. Once self -certification of all points has been reviewed and approved by the Division, it will provide written documentation of such final authorization. Details for obtaining final authorization to operate are located in the Requirements to Self -Certify for Final Authorization section of this permit. 20. This permit is issued in reliance upon the accuracy and completeness of information supplied by the owner or operator and is conditioned upon conduct of the activity, or construction, installation and operation of the source, in accordance with this information and with representations made by the owner or operator or owner or operator's agents. It is valid only for the equipment and operations or activity specifically identified on the permit. 21. Unless specifically stated otherwise, the general and specific conditions contained in this permit have been determined by the APCD to be necessary to assure compliance with the provisions of Section 25-7-114.5(7)(a), C.R.S. 22. Each and every condition of this permit is a material part hereof and is not severable. Any challenge to or appeal of a condition hereof shall constitute a rejection of the entire permit and upon such occurrence, this permit shall be deemed denied ab initio. This permit may be revoked at any time prior to self -certification and final authorization by the Air Pollution Control Division (APCD) on grounds set forth in the Colorado Air Quality Control Act and regulations of the Air Quality Control Commission (AQCC), including failure to meet any express term or condition of the permit. If the Division denies a permit, conditions imposed upon a permit are contested by the owner or operator, or the Division revokes a permit, the owner or operator of a source may request a hearing before the AQCC for review of the Division's action. 23. Section 25-7-114.7(2)(a), C.R.S. requires that all sources required to file an Air Pollution Emission Notice (APEN) must pay an annual fee to cover the costs of inspections and administration. If a source or activity is to be discontinued, the owner must notify the Division in writing requesting a cancellation of the permit. Upon notification, annual fee billing will terminate. 24. Violation of the terms of a permit or of the provisions of the Colorado Air Pollution Prevention and Control Act or the regulations of the AQCC may result in administrative, civil or criminal enforcement actions under Sections 25-7-115 (enforcement), -121 (injunctions), -122 (civil penalties), -122.1 (criminal penalties), C.R.S. By: Andy Gruel, P.E. Permit Engineer Permit History Issuance Date Description Issuance 1 This Issuance Issued to Kerr-McGee Oil and Gas Onshore LP. COLORADO Air Pollution Control Division vE Page 5 of 7 Notes to Permit Holder at the tim 1) The permit holder is requir-_ •ay --s e - =--'ng ti r for this permit. An invoice for these fees will be issued after the permit is issued. The permit holder shall pay the invoice within 30 days of receipt of the invoice. Failure to pay the invoice will result in revocation of this permit. (Regulation Number 3, Part A, Section VI.B.) 2) The production or raw material processing limits and emission limits contained in this permit are based on the consumption rates requested in the permit application. These limits may be revised upon request of the owner or operator providing there is no exceedance of any specific emission control regulation or any ambient air quality standard. A revised air pollution emission notice (APEN) and complete application form must be submitted with a request for a permit revision. 3) This source is subject to the Common Provisions Regulation Part II, Subpart E, Affirmative Defense Provision for Excess Emissions During Malfunctions. The owner or operator shall notify the Division of any malfunction condition which causes a violation of any emission limit or limits stated in this permit as soon as possible, but no later than noon of the next working day, followed by written notice to the Division addressing all of the criteria set forth in Part II.E.1 of the Common Provisions Regulation. See: https://www.colorado.gov/pacific/cdphe/aqcc-regs 4) The following emissions of non -criteria reportable air pollutants are estimated based upon the process limits as indicated in this permit. This information is listed to inform the operator of the Division's analysis of the specific compounds emitted if the source(s) operate at the permitted limitations. Facility Equipment ID AIRS Point Pollutant CAS # Uncontrolled Emissions (lb/yr) Controlled Emissions (lb/yr) VRT-01 008 Benzene 71432 7476 374 Toluene 108883 13440 672 Ethylbenzene 100414 3276 164 Xylenes 1330207 9030 452 n -Hexane 110543 35238 1762 2,2,4- Trimethylpentane 540841 7644 382 Note: All non -criteria reportable pollutants in the table above with uncontrolled emission rates above 250 pounds per year (lb/yr) are reportable and may result in annual emission fees based on the most recent Air Pollution Emission Notice. 5) The emission levels contained in this permit are based on the following emission factors: Point 008: CAS # Pollutant Uncontrolled Emission Factors (lb/bbl) Controlled Emission Factors (lb/bbl) Source N0x 0.061 0.061 CDPHE 2005 Memo CO 0.155 0.155 V0C 16.488 0.8244 EEtP Tank v2.0 based on site -specific pressurized liquids samples 71432 Benzene 0.089 0.0045 108883 Toluene 0.160 0.0080 100414 Ethylbenzene 0.039 0.0020 1330207 Xylene 0.1075 0.0054 110543 n -Hexane 0.4195 0.0210 'COLORADO Air Pollution Control Division Pubi E h. U {•w' - tt�r :ve^;Y Page 6 of 7 A CAS # Pollutant s F rol ontr lion actors (lb ) Source 540841 2'2'4 Trimethylpentane 0.091 0.0046 Note: The controlled emissions factors for this point are based on the enclosed combustor control efficiency of 95%. 6) In accordance with C.R.S. 25-7-114.1, each Air Pollutant Emission Notice (APEN) associated with this permit is valid for a term of five years from the date it was received by the Division. A revised APEN shall be submitted no later than 30 days before the five-year term expires. Please refer to the most recent annual fee invoice to determine the APEN expiration date for each emissions point associated with this permit. For any questions regarding a specific expiration date call the Division at (303)-692-3150. 7) This facility is classified as follows: Applicable Requirement Status Operating Permit Synthetic Minor Source of: VOC, HAPs (total, and n -hexane) NANSR Synthetic Minor Source of: VOC 8) Full text of the Title 40, Protection of Environment Electronic Code of Federal Regulations can be found at the website listed below: http://ecfr.gpoaccess.gov/ Part 60: Standards of Performance for New Stationary Sources NSPS 60.1 -End Subpart A - Subpart KKKK NSPS Part 60, Appendixes Appendix A - Appendix I Part 63: National Emission Standards for Hazardous Air Pollutants for Source Categories MACT 63.1-63.599 Subpart A - Subpart Z MACT 63.600-63.1199 Subpart AA - Subpart DDD MACT 63.1200-63.1439 Subpart EEE - Subpart PPP MACT 63.1440-63.6175 Subpart QQQ - Subpart YYYY MACT 63.6580-63.8830 Subpart ZZZZ - Subpart MMMMM MACT 63.8980 -End Subpart NNNNN - Subpart XXXXXX COLORADO Air Pollution Control Division Page 7 of 7 Permit number: Date issued: Issued to: Co Air Po Depart CONSTRUCTION PERMIT 15WE0910 Facility Name: Plant AIRS ID: Physical Location: County: General Description: Issuance: 1 Kerr-McGee Oil and Gas Onshore LP 34003106 123/4602 SENW Section 26 T2N R66W Weld County Well Production Facility Equipment or activity subject to this permit: Facility Equipment ID AIRS Point Equipment Description Emissions Control Description VRT-O2 009 One (1) vapor recovery tower (VRT) that processes liquid from the second stage of separation to create a third stage of liquid/gas separation. Overhead flash gas from the VRT collected by vapor recovery units (VRUs) in a closed -loop process. When the VRUs are unable to capture the entire overhead gas stream, flash gas is routed to enclosed combustors. Emissions from this point are a function of liquids throughput while overhead gas is routed to the enclosed combustors, and permit limits are based on gas routed to the enclosed combustors 30% of the time. Enclosed Combustors This permit is granted subject to all rules and regulations of the Colorado Air Quality Control Commission and the Colorado Air Pollution Prevention and Control Act (C.R.S. 25-7-101 et seq), to this specific general terms and conditions included in this document and the following specific terms and conditions. REQUIREMENTS TO SELF -CERTIFY FOR FINAL AUTHORIZATION YOU MUST notify the Air Pollution Control Division (the Division) no later than fifteen days of the latter of commencement of operation or issuance of this permit, by submitting a Notice of Startup form to the Division for the equipment covered by this permit. The Notice of Startup COLORADO Air Pollution Control Division Page 1 of 7 form may be download • • a orad . • .v/ • ., ific/cdphe/other-air-permitting- notices. Failure to notif - r i .f s of - per tted source is a violation of Air Quality Control Commis ' •C -n 3, Pa Section III.G.1. and can result in the revocation of the permit. 2. Within one hundred and eighty days (180) of the latter of commencement of operation or issuance of this permit, compliance with the conditions contained in this permit shall be demonstrated to the Division. It is the owner or operator's responsibility to self -certify compliance with the conditions. Failure to demonstrate compliance within 180 days may result in revocation of the permit. A self certification form and guidance on how to self -certify compliance as required by this permit may be obtained online at www.colorado.gov/pacific/cdphe/air-permit-self-certification. (Regulation Number 3, Part B, Section III.G.2.) 3. This permit shall expire if the owner or operator of the source for which this permit was issued: (i) does not commence construction/modification or operation of this source within 18 months after either, the date of issuance of this construction permit or the date on which such construction or activity was scheduled to commence as set forth in the permit application associated with this permit; (ii) discontinues construction for a period of eighteen months or more; (iii) does not complete construction within a reasonable time of the estimated completion date. The Division may grant extensions of the deadline. (Regulation Number 3, Part B, Section III.F.4.) 4. The operator shall complete all initial compliance testing and sampling as required in this permit and submit the results to the Division as part of the self -certification process. (Regulation Number 3, Part B, Section III.E.) 5. The operator shall retain the permit final authorization letter issued by the Division, after completion of self -certification, with the most current construction permit. This construction permit alone does not provide final authority for the operation of this source. EMISSION LIMITATIONS AND RECORDS 6. Emissions of air pollutants shall not exceed the following limitations. (Regulation Number 3, Part B, Section II.A.4.) Annual Limits: Facility Equipment ID AIRS Point Tons per Year Emission Type PM2.5 NO. VOC CO VRT-02 009 --- --- 4.8 --- Point Note: See "Notes to Permit Holder" for information on emission factors and methods used to calculate limits. Facility -wide emissions of each individual hazardous air pollutant shall not exceed 8.0 tons per year. Facility -wide emissions of total hazardous air pollutants shall not exceed 20.0 tons per year. The facility -wide emissions limitation for hazardous air pollutants shall apply to all permitted emission units at this facility. Compliance with the annual limits, for both criteria and hazardous air pollutants, shall be determined on a rolling twelve (12) month total. By the end of each month a new twelve month total is calculated based on the previous twelve months' data. The permit holder shall calculate actual emissions each month and keep a compliance record on site or at a local field office with site responsibility for Division review. COLORADO Air Pollution Control Division a cr FUU . a awir rsne,:t Page 2 of 7 7. The emission points in control equipment as lis established in this perm maintained with the emissions ess than or equal to the limits Sects III.E.) Facility Equipment ID AIRS Point Control Device Pollutants Controlled VRT-O2 009 Emissions from the vapor recovery tower are routed to enclosed combustors (Make: Cimarron, model: 48" HVECD) when Vapor Recovery Unit (VRU) is unable to recover all vapors. VOC and HAP PROCESS LIMITATIONS AND RECORDS 8. This source shall be limited to the following maximum processing rates as listed below. Monthly records of the actual processing rates shall be maintained by the owner or operator and made available to the Division for inspection upon request. (Regulation Number 3, Part B, II.A.4.) Process Limits Facility Equipment ID AIRS Point Process Parameter Annual Limit VRT-O2 009 Liquids Throughput through VRT while gas is routed from VRT to enclosed combustors 11,550 bbl/yr Compliance with the annual throughput limits shall be determined on a rolling twelve (12) month total. By the end of each month a new twelve-month total is calculated based on the previous twelve months' data. The permit holder shall calculate throughput each month and keep a compliance record on site or at a local field office with site responsibility, for Division review. 9. The owner or operator shall use VRT liquids throughput records, calculation methods detailed in the O&M Plan, and the emission factors established in the Notes to Permit Holder to demonstrate compliance with the process and emissions limits specified in this permit. STATE AND FEDERAL REGULATORY REQUIREMENTS 10. The permit number and ten digit AIRS ID number assigned by the Division (i.e., 123/4602/009) shall be marked on the subject equipment for ease of identification. (Regulation Number 3, Part B, Section III.E.) (State only enforceable) 11. No owner or operator of a smokeless flare or other flare for the combustion of waste gases shall allow or cause emissions into the atmosphere of any air pollutant which is in excess of 30% opacity for a period or periods aggregating more than six minutes in any sixty consecutive minutes. (Regulation Number 1, Section II.A.5.) 12. This source is subject to the odor requirements of Regulation Number 2. (State only enforceable) OPERATING It MAINTENANCE REQUIREMENTS 13. Upon startup of this point, the owner or operator shall follow the most recent operating and maintenance (O&M) plan and record keeping format approved by the Division, in order to demonstrate compliance on an ongoing basis with the requirements of this permit. Revisions to the OFtM plan are subject to Division approval prior to implementation. (Regulation Number 3, Part B, Section III.G.7.) COMPLIANCE TESTING AND SAMPLING COLORADO Air Pollution Control Division Page 3 of 7 • Initial Testing Requirem 14. The owner or operator de on ra c li ce wi opacity standards, using EPA Reference Method 9, 41 .R. Part 60, ppen ix , to measure opacity from the flare. The observation period shall be 1 hour in duration. (Regulation Number 1, Section II.A.5) Periodic Testing Requirements 15. This source is not required to conduct periodic testing, unless otherwise directed by the Division or other state or federal requirement. ADDITIONAL REQUIREMENTS 16. A revised Air Pollutant Emission Notice (APEN) shall be filed: (Regulation Number 3, Part A, II.C.) • Annually by April 30th whenever a significant increase in emissions occurs as follows: For any criteria pollutant: For sources emitting less than 100 tons per year, a change in actual emissions of five (5) tons per year or more, above the level reported on the last APEN; or For volatile organic compounds (VOC) and nitrogen oxides sources (NOr) in ozone nonattainment areas emitting less than 100 tons of VOC or NO, per year, a change in annual actual emissions of one (1) ton per year or more or five percent, whichever is greater, above the level reported on the last APEN; or For sources emitting 100 tons per year or more, a change in actual emissions of five percent or 50 tons per year or more, whichever is less, above the level reported on the last APEN submitted; or For any non -criteria reportable pollutant: If the emissions increase by 50% or five (5) tons per year, whichever is less, above the level reported on the last APEN submitted to the Division. • Whenever there is a change in the owner or operator of any facility, process, or activity; or • Whenever new control equipment is installed, or whenever a different type of control equipment replaces an existing type of control equipment; or Whenever a permit limitation must be modified; or • No later than 30 days before the existing APEN expires. 17. Federal regulatory program requirements (i.e. PSD, NANSR) shall apply to this source at any such time that this source becomes major solely by virtue of a relaxation in any permit condition. Any relaxation that increases the potential to emit above the applicable Federal program threshold will require a full review of the source as though construction had not yet commenced on the source. The source shall not exceed the Federal program threshold until a permit is granted. (Regulation Number 3, Parts C and D). GENERAL TERMS AND CONDITIONS 18. This permit and any attachments must be retained and made available for inspection upon request. The permit may be reissued to a new owner by the APCD as provided in AQCC Regulation Number 3, Part B, Section II.B. upon a request for transfer of ownership and the submittal of a revised APEN and the required fee. 19. If this permit specifically states that final authorization has been granted, then the remainder of this condition is not applicable. Otherwise, the issuance of this construction permit does not provide "final" authority for this activity or operation of this source. Final authorization of the COLORADO Air Pollution Control Division Page 4 of 7 permit must be secured e P in 'ng i a cord ce with the provisions of 25-7- 114.5(12)(a) C.R.S. and ► g 'n N 3, a t B, ction III.G. Final authorization cannot be granted until = - -ra o - it nce has been verified by the APCD as conforming in all respects with the conditions of the permit. Once self -certification of all points has been reviewed and approved by the Division, it will provide written documentation of such final authorization. Details for obtaining final authorization to operate are located in the Requirements to Self -Certify for Final Authorization section of this permit. 20. This permit is issued in reliance upon the accuracy and completeness of information supplied by the owner or operator and is conditioned upon conduct of the activity, or construction, installation and operation of the source, in accordance with this information and with representations made by the owner or operator or owner or operator's agents. It is valid only for the equipment and operations or activity specifically identified on the permit. 21. Unless specifically stated otherwise, the general and specific conditions contained in this permit have been determined by the APCD to be necessary to assure compliance with the provisions of Section 25-7-114.5(7)(a), C.R.S. 22. Each and every condition of this permit is a material part hereof and is not severable. Any challenge to or appeal of a condition hereof shall constitute a rejection of the entire permit and upon such occurrence, this permit shall be deemed denied ab initio. This permit may be revoked at any time prior to self -certification and final authorization by the Air Pollution Control Division (APCD) on grounds set forth in the Colorado Air Quality Control Act and regulations of the Air Quality Control Commission (AQCC), including failure to meet any express term or condition of the permit. If the Division denies a permit, conditions imposed upon a permit are contested by the owner or operator, or the Division revokes a permit, the owner or operator of a source may request a hearing before the AQCC for review of the Division's action. 23. Section 25-7-114.7(2)(a), C.R.S. requires that all sources required to file an Air Pollution Emission Notice (APEN) must pay an annual fee to cover the costs of inspections and administration. If a source or activity is to be discontinued, the owner must notify the Division in writing requesting a cancellation of the permit. Upon notification, annual fee billing will terminate. 24. Violation of the terms of a permit or of the provisions of the Colorado Air Pollution Prevention and Control Act or the regulations of the AQCC may result in administrative, civil or criminal enforcement actions under Sections 25-7-115 (enforcement), -121 (injunctions), -122 (civil penalties), -122.1 (criminal penalties), C.R.S. By: Andy Gruel, P.E. Permit Engineer Permit History Issuance Date Description Issuance 1 This Issuance Issued to Kerr-McGee Oil and Gas Onshore LP. COLORADO Air Pollution Control. Division Page 5 of 7 Notes to Permit Holder at the ti 1) The permit holder is requir: -' ' ay ng ti a for this permit. An invoice for these fees will be issued after the permit is issued. The permit holder shall pay the invoice within 30 days of receipt of the invoice. Failure to pay the invoice will result in revocation of this permit. (Regulation Number 3, Part A, Section VI.B.) 2) The production or raw material processing limits and emission limits contained in this permit are based on the consumption rates requested in the permit application. These limits may be revised upon request of the owner or operator providing there is no exceedance of any specific emission control regulation or any ambient air quality standard. A revised air pollution emission notice (APEN) and complete application form must be submitted with a request for a permit revision. 3) This source is subject to the Common Provisions Regulation Part II, Subpart E, Affirmative Defense Provision for Excess Emissions During Malfunctions. The owner or operator shall notify the Division of any malfunction condition which causes a violation of any emission limit or limits stated in this permit as soon as possible, but no later than noon of the next working day, followed by written notice to the Division addressing all of the criteria set forth in Part II.E.1 of the Common Provisions Regulation. See: https://www.colorado.gov/pacific/cdphe/aqcc-regs 4) The following emissions of non -criteria reportable air pollutants are estimated based upon the process limits as indicated in this permit. This information is listed to inform the operator of the Division's analysis of the specific compounds emitted if the source(s) operate at the permitted limitations. Facility Equipment ID AIRS Point Pollutant CAS # Uncontrolled Emissions (lb/yr) Controlled Emissions (lb/yr) VRT-02 009 Benzene 71432 1028 51 Toluene 108883 1848 92 Ethylbenzene 100414 450 23 Xylenes 1330207 1242 62 n -Hexane 110543 4845 242 2,2,4- Trimethylpentane 540841 1051 53 Note: All non -criteria reportable pollutants in the table above with uncontrolled emission rates above 250 pounas per year (lb/yr) are reportable and may result in annual emission fees based on the most recent Air Pollution Emission Notice. 5) The emission levels contained in this permit are based on the following emission factors: Point 009: CAS # Pollutant Uncontrolled Emission Factors (lb/bbl) Controlled Emission Factors (lb/bbl) Source N0x 0.061 0.061 CDPHE 2005 Memo CO 0.155 0.155 V0C 16.488 0.8244 EEtP Tank v2.0 based on site -specific pressurized liquids samples 71432 Benzene 0.089 0.0045 108883 Toluene 0.160 0.0080 100414 Ethylbenzene 0.039 0.0020 1330207 Xylene 0.1075 0.0054 110543 n -Hexane 0.4195 0.0210 COLORADO Air Pollution Control Division i_J% F LTrilrfAvrt,f1C. Page 6 of 7 A "1-1 1-1-1 CAS # Pollutant roll s F f{ontjed sionctors (lb) Source 540841 2, Trimethylpentane 0.091 0.091 0.0046 Note: The controlled emissions factors for this point are based on the enclosed combustor control efficiency of 95%. 6) In accordance with C.R.S. 25-7-114.1, each Air Pollutant Emission Notice (APEN) associated with this permit is valid for a term of five years from the date it was received by the Division. A revised APEN shall be submitted no later than 30 days before the five-year term expires. Please refer to the most recent annual fee invoice to determine the APEN expiration date for each emissions point associated with this permit. For any questions regarding a specific expiration date call the Division at (303)-692-3150. 7) This facility is classified as follows: Applicable Requirement Status Operating Permit Synthetic Minor Source of: VOC, HAPs (total, and n -hexane) NANSR Synthetic Minor Source of: VOC 8) Full text of the Title 40, Protection of Environment Electronic Code of Federal Regulations can be found at the website listed below: http://ecfr.gpoaccess.gov/ Part 60: Standards of Performance for New Stationary Sources NSPS 60.1 -End Subpart A - Subpart KKKK NSPS Part 60, Appendixes Appendix A - Appendix I Part 63: National Emission Standards for Hazardous Air Pollutants for Source Categories MACT 63.1-63.599 Subpart A - Subpart Z MACT 63.600-63.1199 Subpart AA - Subpart DDD MACT 63.1200-63.1439 Subpart EEE - Subpart PPP MACT 63.1440-63.6175 Subpart QQQ - Subpart YYYY MACT 63.6580-63.8830 Subpart ZZZZ - Subpart MMMMM MACT 63.8980 -End Subpart NNNNN - Subpart XXXXXX COLORADO Air Pollution Control Division Page 7 of 7 AIR POLLUTANT EMISSION NOTICE (APEN) & Application for Construction Permit — Generals N O M N Emission Source AIRS ID: [Leave blank unless APCD has already assigned a permit # & Permit Number: [Provide Facility Equipment ID to identify how this equipment is referenced within your organization.] Facility Equipment ID: uested Action (check applicable request boxes) Section 02 — Re Section 01— Administrative Information Request for NEW permit or newly reported emission source Request PORTABLE source permit a) as O. O. .O O .O O O O O O C3 U 102 E L a r O z O U COI r C C' ® ❑ ❑ o 0 UU z� Source Name: Change fuel or equipment !•. .O 0 O Transfer of ownership Change permit limit ❑ ❑ N 0 O o O A C4 „ 0 O Request to limit HAPs with a Federally enforceable limit on PTE Request APEN Update ❑ ❑ r N O 00 ai O O U Cam. N Emissions data must be completed Blank APENs will not be accepted Denver, CO 80217-3779 Requesting individual permit for vapor recovery tower (VRT) Section 03 — General Information tart °) h O E. 0 O. O co O g 0 5 O ° a. o. O 0 o i „ c a) o O O UCI-. • 0 O O ¢, o an •� an 6 a U q 0 , "O 0 0 0 0 O 0 w z C7 c d E C O L -- OA Q-. CC a o d > CO O ° e Q' o O U -1-, d • L O F obP r C E C o 5.. co � c (.4 w 614 ^C u .O CO 3 O � C 0 L �� � O 0 0 o z eneenw 0 4. Z a w b n VD ...." b°1 y o y to O a I. o O o 4) O o Q g .C 4 ..',/' C U 2 .:0 C N b ? O g CO G, W w a� ermitstatus °J O O C) O ://www.colorado Application status: htt O z 7) col +0.0 O0 0 G a_ w z g -08 .5 °' � O O 0 O N L a. 8 „ ti 3� ment Information & Material Use Section 04 — Processinff/IVIanufacturin Description of equipment': O z COciD z O O Manufacturer: O a. • 5- U a) 40 N U, O -o O o iw a Other Process Check box to request copy of draft permit prior to issuance. Check box to request copy of draft permit prior to public notice. N El R .0 O L co, _L T ao O „ Q C°Xi O C C y E o C O O. O CO O 44 o g 0 •O y N O L y U u 0 a 0 8 O dO ^ „ O w 0coo O. at y actd z Lalco .- O o. a „ o w 9 „ o o.fl p d .: bp „ ti 50 cO O .O a u ii v771 O O Form APCD-200 — GeneralAPEN — Ver.02.10.2014.docx N O a) O C\1 CD CM•.! Cr) Cr) FORM APCD-200 ce▪ t rrU� N O CD N Emission Source AIRS ID: Permit Number: H fr O 0 O as L U b Q ¢1 a.) G U a) 0 .5 cot U TO c�a 0 F o o NN tQ U 0 0 0 C7 N 4.1 -104.7392614 .ti CZ z� N x� 00 00 V O oa 0 O o It 00 p U U 0 0 O CO O 0 O Vertical with obstructing raincap Direction of outlet (check one): Width (inches) = Other: Length (inches) = 00 ment & Fuel Consumption Information Section 06 — Combustion E Multiple ECDs 48" HVECD U .b 0 C: 0 R E Manufacturer: CO CO 4.4 0 O 71) 0 U 00 a co U U U Q N N N Ira N U U O CO z U U CO U O 00 U U 0 O. .b 0 CO 7 O y v U U O. O .9 C. 8 U �3 a b .U. Section 07 — Emissions Inventory Information & Emission Control Information 0 0 0 tri U CO U 0 b O U �Fd CO 0 • CO • O O U U 0 0 U U E U L L R 'O CO U CC U R i L L U a U U U w CO O W a E O 0 L 8 O CO co, E Estimation Method or Emission Factor Source 2005 APCD E&P Tank 2005 APCD Please use the APCD Non -Criteria Re i ortable Air Pollutant Addendum form to report pollutants not listed above. Requested Permitted Emissions Uncontrolled Controlled (Tons/Year) (Tons/Year) 2.56 N `41 c•-) r•y In vz i 692.5 Actual Calendar Year Emissions4 Uncontrolled Controlled (Tons/Year) (Tons/Year) Emission Factor Uncontrolled Units Basis - 0 a 0 0 .0 .0 0.0037 00 0 0 — Q Control Efficiency (% Reduction) 95 Overall Collection Efficiency Control Device Description Secondary Primary U i. W Pollutant TSP N N X xON II II VOC 0 co O M L L a CO. U L CO C 00 E C O O E L C 0 7a U U O U O CO U 61 0 Ti VJ � O O R b U 0 O U 4. O � W E �3 0 L C •y • 3 E C 0 w U U U O U R U ▪ a o UU. +.� xH O U C O CO a 0. CO U 1.1 O O R E CO C R C U 0. U b U CO R CO O U C'. O R B w R U C 0 R w resentative David Steller Name of Legally Authorized Person (Please print) ed to Supply Data Form APCD-200 — GeneralAPEN — Ver.02.10.2014.docx N W O 0-0 U CO 0.1 5 Z W D W C) F- 0 Z Z co to cn N W .;' I — Z E Q O U O c J -CJ 03 rn CL Q N w1,51 J CO O w re cL V O AIRS ID Number: 123-4602-Tt7 tip Permit Number: Kerr-McGee Oil and Gas Onshore LP Company Name: ti N O co a) -o O U 0 N -o a) _A 0 U SENW S26 T2N R66W Plant Location: a) U) a) L co O a a) L Person to Contact: Carissa.krey@anadarko.com E-mail Address: Controlled Actual Emissions (lbs/year) CO CO l- �? in N ~ co Uncontrolled Actual Emissions (lbs/year) 7476 13440 3276 9030 CO CO N U, CO 7644 Emission Factor Source YC a I— o w E&P Tank E&P Tank Y C I ces w E&P Tank E&P Tank Emission Factor (Include Units) -O O O O D _0 M0 O O _a v- O n _a N O _a _a O O O Control Equipment / Reduction (%) U) 0) 95 95 95 95 95 Chemical Name Benzene Toluene E -Benzene Xylene N -Hexane 224 -TM P Chemical Abstract Service (CAS) Number O cc a) c 0 .U) U) E w T. a) s a) a) o_ a- co 0 To U U L a) } a) U co a) O 0- 0- 0 N L O -C 0) a> -J O L a) a 0 m L a) VJ HSE Representative Lm rn a) l v/ co O Title of Person Legally Authorized to Supply Data Name of Person Legally Authorized to Supply Data (Please print) Form Revision Date: April 14. 2014 AIR POLLUTANT EMISSION NOTICE (APEN) & Application for Construction Permit — Genera11 Emission Source AIRS ID: A [Leave blank unless APCD has already assigned a permit # & Permit Number: O CO O O 5 C) U 0 as N W N CO c. CO 0 G b a CO U w a CO Facility Equipment ID: uested Action (check applicable request boxes) Section 02 — Re Section 01— Administrative Information Request for NEW permit or newly reported emission source Kerr-McGee Oil and Gas Onshore LP Request PORTABLE source permit C) CO Cd 0 o 0 r cu CO a) C) U d a et CO 4S 41 0 U G7. 0 7 7 c a Change company name C) 0 Transfer of ownership ❑ ❑ Change fuel or equipment Change permit limit ❑ ❑ Request to limit HAPs with a Federally enforceable limit on PTE Request APEN Update 1.0 0 00 C) -a 0 C.) a N Emissions data must be completed Blank APENs will not be accepted Denver, CO 80217-3779 Requesting individual permit for vapor recovery tower (VRT) Section 03 — General Information N COO 4- v act a, d 733. Cr 0 01) CI 0) 7 CO L CO M y O L N GL 0- CO CO O LL HI O 0 0 N y cr. tat 0 a) ° 0 0 vi CO0 CID L CO CO O. v 0 U CO -CO U • X COCO N CO O a) w Z 0 APEN forms: httn://www.colorado.eov/cd ermitstatus U CO b 0 ://www.colorado. Application status: htt 0 z Yes ❑ �l Use Serial No.: C) Q U CO 0 O a w z g . 5, ^O O a) 0as ,b O O p U CO O" U a • as 33 U, /Manufacturin Section 04 — Processin Description of equipment2: C) b Manufacturer: Description 4-4 Other Process: Check box to request copy of draft permit prior to issuance. R s a ai u 2.7 O" lE cei C) as w aC) C .y CO CO ta as on O as CO COro 'o y i CO L I U u E C C O p,a) 'CO O as aJ CT, - F4 0 w y N _ 7 Cy CG a 0 a) N .s z ; c a w a y a o o o •3 a) CO d 3 et U cn 4) CO cd .0 any U vl O C) :0cr CO cCI (24 a) Form APCD-200 — GeneralAPEN — Ver.02.10.2014.docx N w CO bA O FORM APCD-200 AIR POLLUTANT EMISSION NOTICE (APEN) & Application for Construction Permit — General' N O CO M N Emission Source AIRS ID: Permit Number: Section 05 — Emission Release Information (Attach a separate sheet with relevant information in the event of multiple releases; provide datum & either Lat/Long or UTM) 4:3 z 0) 0 .- 4- O 0 0 0 N N ti -104.7392614 0 0 NN ti 0 N 0 E 4) w a It 00 0 Other (Describe): Width (inches) = D Horizontal 0 Down 0 Other: Length (inches) = Vertical with obstructing raincap 00 R .0 U I- ❑ 4 U U 4? d C O C) u Z 4) N U V) 0.0 Q 4) 0 w Direction of outlet (check one): ment & Fuel Consumntion Information Section 06 — Combustion E Multiple ECDs 0 z 44 4) 48" HVECD 4) 0 0 O L 444 G Manufacturer: Company equipment Identification No.: VRT ECD-04 0) 4) v P, 44)) 44 0 5 w 0 2 3 4) Q CE 44 N N N In N N 00 44 0) p Natural Gas Section 07 — Emissions Inventory Information & Emission Control Information O N 0 0 n .0 w _ L .0 0 w = O E o e¢ O d u . R V O 4= a+ L o •-44, 4) 5 A 0 0 w 0 d u a,= b = 44 O 0 = O � a 4.) C.) ed A U 0 0 O u • EnCC W o = 4) O_ Cd iE U ¢® Estimation Method or Emission Factor Source 2005 APCD II E&P Tank Please use the APCD Non -Criteria Re sortable Air Pollutant Addendum form to re sort • ollutants not listed above. Requested Permitted Emissions Controlled (Tons/Year) 0.35 N er a C Uncontrolled (Tons/Year) i I 95.2 I i Actual Calendar Year Emissions4 Controlled (Tons/Year) Uncontrolled (Tons/Year) Emission Factor Units Ib/IbVOC Ib/IbVOC Uncontrolled Basis 0.0037 00 et 00 O\ rl O O Control Efficiency (% Reduction) 95 Overall Collection Efficiency Control Device Description b O N v) a) a R Pollutant TSP a O C) XON DOA II CO licant Certification - I hereby certify that all information contained herein and information submitted with this application is complete, true and correct. Section 08 —A resentative Signature of Person Legally Authorized to Supply Dat 2 w O w 0 I 0 z z 0 V# Cl) 2) w s 0 aOE 1 J c Jco 0' rn Nao to N W 116) MJ > W Q re O a re w H ce V 0 z AIRS ID Number: 123-4602-TBD-- 00 G% Permit Number: Kerr-McGee Oil and Gas Onshore LP Company Name: ti N O co SENW S26 T2N R66W Plant Location: Person to Contact: Carissa.krey@anadarko.com E-mail Address: Controlled Actual Emissions (lbs/year) to co N co N N u Uncontrolled Actual Emissions (lbs/year) 1028 1848 450 1242 to Tr co v 1051 Emission Factor Source - c I- 05 w E&P Tank Y c F- 05 w &P Tank E&P Tank E&P Tank Emission Factor (Include Units) . rn O O -2 -- - m z .0 O) N) O z .0 - co O O T, .0 O N O .0 N. O) O Control Equipment / Reduction (%) 0) O) 95 95 95 0) Chemical Name Benzene Toluene E -Benzene Xylene N -Hexane 224 -TM P Chemical Abstract Service (CAS) Number HSE Representative Title of Person Legally Authorized to Supply Data Name of Person Legally Authorized to Supply Data (Please print) Form Revision Date: April 14. 2014 Hello