HomeMy WebLinkAbout20173431.tiffMEMORANDUM
TO: Diana Aungst, Planning Services
DATE: August 10, 2017
FROM: Hayley Balzano, E.I., Development Engineer
SUBJECT: USR17-0037 Arter
The Weld County Department of Planning Services -Engineering has reviewed this proposal. Staff
comments made during this phase of the application process may not be all-inclusive, as other issues may
arise during the remaining application process.
COMMENTS:
General Project Information/Location:
Project description: Commercial Truck Parking
This project is west of and adjacent to County Road and is north of County Road.
Parcel number: 130713400025
Drainage Requirements:
Please contact Department of Planning Services/Engineering Development Review for questions or
assistance for drainage requirements at 970-353-6100.
URBANIZING VS NON -URBANIZING DRAINAGE AREA:
This area IS within a Non -Urbanizing Drainage Area:
Non -Urbanizing Drainage Areas typically require detention of runoff from the 1 -hour, 100 -year, storm falling
on the developed site and release of the detained water at the historic runoff rate of the 1 -hour, 10 -year
storm falling on the undeveloped site for NON -URBANIZING areas.
Detention pond waived and a simple drainage narrative:
There was a recent 1600 square foot addition to the outbuilding on site. The site qualifies for exception
1.a.14 for a parcel greater than 5 gross acres in size is allowed a onetime exception for a new 2,000 square
foot building or equivalent imperviousness.
Geologic Hazard Area:
This area IS NOT in a Geologic Hazard Area.
Floodplain:
This area IS NOT in a FEMA regulatory floodplain.
CONDITIONS OF APPROVAL:
A. The plan shall be amended to delineate the following:
1. The applicant shall show the drainage flow arrows. (Department of Planning Services -Engineer)
2. Show and label the parking on the property. (Department of Planning Services -Engineer)
DEVELOPMENT STANDARDS (NOTES ON THE SITE PLAN)
1. The historical flow patterns and runoff amounts on the site will be maintained. (Department of Planning
Services -Engineer)
MEMORANDUM
TO: Diana Aungst, Planning Services
FROM: Evan Pinkham, Public Works
SUBJECT: USR17-0037 Arter
DATE: August 8, 2017
The Weld County Department of Public Works has reviewed this proposal. Staff comments made during
this phase of the application process may not be all-inclusive, as other issues may arise during the
remaining application process.
COMMENTS
GENERAL PROJECT INFORMATION/LOCATION
Project description: A Site Specific Development Plan and Use by Special Review Permit for A Use
Permitted as a Use by Right, an Accessory Use, or a Use by Special Review in the Commercial or Industrial
Zone Districts (commercial truck parking) provided that the property is not a lot in an approved or recorded
subdivision plat or lots part of a map or plan filed prior to adoption of any regulations controlling subdivisions
in the A (Agricultural) Zone District
This project is west of and adjacent to CR 49 and is south of CR 22. Parcel number 130713400025.
Access is from CR 49.
ACCESS
An Access Permit application was submitted with the application materials. Public Works will review the
application and provide an access permit and permit number if approved. Questions concerning access
requirements can be directed to Public Works access permit division.
Per Chapter 12, Article 5, Section 12-5-30, an Access Permit is required for access to Weld County
maintained roadways. We strongly encourage you to discuss your access with public works prior to laying
out your site plan to ensure the approved accesses are compatible with your layout.
For new accesses and/or change of use of an existing access, the fee and photos are required (photo
looking left and right along roadway from the access point and looking in to and out of the access point).
These photos are used to evaluate the safety of the access location. Access permit instructions and
application can be found at https://www.weldgov.com/departments/publIc works/permits/. Chapter 6,
Sections 6.3, 6.4 and 6.5 of the Weld County Engineering and Construction Criteria offer access design
guidance, which can be accessed at: https://www weldgov com/departments/public works/engineering/.
For shared accesses, Public Works strongly recommends the property owner establish an access road
maintenance agreement so future owners of the properties will be aware of their requirements for shared
maintenance of the access road. This is not a requirement, but is recommended to avoid property owner
conflicts in the future.
Per Chapter 12, Appendix 12A.4.1 of the Weld County Code, an access approach that is gated shall be
designed so that the longest vehicle (including trailers) using the access can completely clear the traveled
way when the gate is closed. In no event, shall the distance from the gate to the edge of the traveled surface
be less than 35 feet.
ROADS AND RIGHTS -OF -WAY
County Road 49 is designated on the Weld County Functional Classification Map (Code Ordinance 2017-
01) as an arterial road, which requires a minimum of 140 feet of right-of-way, or 180 feet of right-of-way in
some locations. Weld County is currently in the process of widening this corridor, which is anticipated to be
completed at the end of 2017. Contact Public Works for the location of the current right-of-way alignment
and easements so they can be delineated accurately on the map. If the right-of-way cannot be verified it
shall be dedicated. The applicant shall also delineate the physical location of the road. Pursuant to the
definition of setback in the Weld County Code, Chapter 23, Article III, Section 23-3-50, the required setback
is measured from the future right-of-way line. This road is maintained by Weld County.
Weld County will not replace overlapping easements located within existing right-of-way or pay to relocate
existing utilities within the County right-of-way.
TRAFFIC
Latest ADT on CR 49 was taken on 3/6/2013 which counted 4640 vpd with 46% trucks.
A traffic narrative was submitted with the application materials and indicated that there will be approximately
3 daily roundtrips. The expected traffic routes are north and south along CR 49 and distribution of traffic is
estimated to be 66.6% to south 33.3% to north.
TRACKING CONTROL POLICY
Per Chapter 12, Appendix 12A.10.1, traffic volumes to the proposed facility may require the installation of
a tracking control device and/or a minimum of four inches of compacted recycled asphalt or aggregate road
base. Tracking control is required to prevent tracking from the site onto public roadways. Minimal standards
are listed below. Temporary Tracking Control shall be used during construction unless permanent tracking
control is installed ahead of construction activities.
Less than 20 passenger vehicle round trips/day, no upfront tracking control requirements.
CONDITIONS OF APPROVAL
A. The plan shall be amended to delineate the following:
1. County Road 49 is designated on the Weld County Functional Classification Map as an arterial
road which typically requires 140 feet of right-of-way at full build out. Weld County is currently in
the process of widening this corridor. The alignment of the road widening project varies along the
section line for the corridor. Contact Public Works for the location of the existing and future right-
of-way and easements and delineate these on the site plan. (Department of Public Works)
2. Show and label the approved access(es) (APXX-XXXXX), and the appropriate turning radii (60')
on the site plan. (Department of Public Works)
3. Show and label the entrance gate if applicable. An access approach that is gated shall be designed
so that the longest vehicle (including trailers) using the access can completely clear the traveled
way when the gate is closed. In no event, shall the distance from the gate to the edge of the traveled
surface be less than 35 feet. (Department of Public Works)
DEVELOPMENT STANDARDS (NOTES ON THE SITE PLAN)
1. The property owner shall control noxious weeds on the site. (Department of Public Works)
2. The access on the site shall be maintained to mitigate any impacts to the public road including damages
and/or offsite tracking. (Department of Public Works)
3. There shall be no parking or staging of vehicles on public roads. On -site parking shall be utilized.
(Department of Public Works)
WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT
1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth.org
Memorandum
To: Dianna Aungst
From: Lauren Light, Environmental Health Services
Date: August 3, 2017
Re: USR17-OO37 Arter
Environmental Health Services has reviewed this proposal for A Use Permitted
as a Use by Right, an Accessory Use, or a Use by Special Review in the
Commercial or Industrial Zone Districts (commercial truck parking) provided that
the property is not a lot in an approved or recorded subdivision plat or lots part
of a map or plan filed prior to adoption of any regulations controlling
subdivisions in the A (Agricultural) Zone District.
A domestic well (177800) and a septic system permitted for 4 bedrooms
(G19940270) serve the existing residence.
The application indicates there are 3 employees plus the owner. A portable
toilet and bottled water can be used for employees who are on site for 2
consecutive hours or less and 2 or less full time employees on site. The
application states that a portable toilet will be utilized which is acceptable per EH
policy. There will be no fuel storage, washing or floor drains on site.
We recommend that the following requirements be incorporated into the permit
as development standards:
1. All liquid and solid wastes (as defined in the Solid Wastes Disposal
Sites and Facilities Act, 30-20-100.5, C.R.S.) shall be stored and
removed for final disposal in a manner that protects against surface and
groundwater contamination.
2. No permanent disposal of wastes shall be permitted at this site. This is
not meant to include those wastes specifically excluded from the
definition of a solid waste in the Solid Wastes Disposal Sites and
Facilities Act, 30-20-100.5, C.R.S.
Health Administration
Vital Records
lot: 9/0 304 6410
Fax: 9/0-301-64 I'2
Public Health &
Clinical Services
Icic: 9/0 304 6420
Fax: 910-304-64 16
Environmental Health
Services
Tele:970-304-6415
Fax. 970-304-6411
Communication,
Education & Planning
Tele: 970-304-6470
Fox: 970-304-6452
Emergency Preparedness
8 Response
Te le: 970-304-6470
Fax: 970-304-6462
Public Health
3. Waste materials shall be handled, stored, and disposed in a manner
that controls fugitive dust, fugitive particulate emissions, blowing debris,
and other potential nuisance conditions. The applicant shall operate in
accordance with Chapter 14, Article 1 of the Weld County Code.
4. Fugitive dust should attempt to be confined on the property. Uses on
the property should comply with the Colorado Air Quality Commission's
air quality regulations.
5. The facility shall adhere to the maximum permissible noise levels
allowed in the Commercial Zone as delineated in 25-12-103 C.R.S.
6. Adequate drinking, hand washing and toilet facilities shall be provided
for employees, at all times. For employees or contractors on site for
less than 2 consecutive hours a day, and 2 or less full time employees
on site, portable toilets and bottled water are acceptable. Records of
maintenance and proper disposal for portable toilets shall be retained
on a quarterly basis and available for review by the Weld County
Department of Public Health and Environment. Portable toilets shall be
serviced by a cleaner licensed in Weld County and shall contain hand
sanitizers.
7. Any septic system located on the property must comply with all
provisions of the Weld County Code, pertaining to On -site Wastewater
Treatment Systems.
8. A permanent, adequate water supply shall be provided for drinking and
sanitary purposes.
9. The operation shall comply with all applicable rules and regulations of
State and Federal agencies and the Weld County Code.
MEMORANDUM
To: Diana Aungst, Planner July 13, 2017
From: Bethany Pascoe, Zoning Compliance Officer
Subject: USR17-0037 Referral
Upon review of my case files and computer, an active Zoning Violation (ZCV17-00118) was noted. This
violation was initiated due to the presence of multiple commercial vehicles without first completing the
necessary Weld County Zoning Permits. This case has NOT been forwarded to the County Attorney's
Office; therefore, an investigation fee is NOT required.
Due to records release laws, staff no longer tracks complainant information, but please be aware it is
staff's policy to no longer accept staff initiated complaints.
Approval of this application by the Board of County Commissioners would correct the outstanding
violations. If this application is denied, the Department of Planning Services asks that the Board forward
these cases to the County Attorney's Office for legal action through the District Court process, but to delay
that legal action for 30 (thirty) days to allow the applicant time to remove all but 1 (one) Commercial
Vehicle from the property (which would be permissible as an Accessory Use in the Agricultural Zone
District).
SERVICE, TEAMWORK: INTEGRI FY: QUALIFY