Loading...
HomeMy WebLinkAbout20180038.tiffForm No GWS-25 APPLICANT OFFICE OF THE STATE ENGINEER COLORADO DIVISION OF WATER RESOURCES 818 Centennial Bldg . 1313 Sherman St., Denver. Colorado 80203 (303) 866-3581 LI WELL PERMIT NUMBER 303055 DIV. 1 WD 2 DES. BASIN MD ALLIANCE INVESTMENT GROUP FT LUPTON LLC 3035 S ELLSWORTH RD STE 146 MESA, AZ 85212- (480) 980-0060 PERMIT TO CONSTRUCT A WELL APPROVED WELL LOCATION WELD COUNTY NE 1/4 SW 114 Section 11 Township 1 N Range 66 W Sixth P.M DISTANCES FOM SECTION LINES 2608 Ft. from South 1847 Ft. from West LITM COORDINATES Easting: Section Line Section Line Meters.Zcr e:_13 NAD6S Northing: 5) 6) 7) ) ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL This well shall be used in such a ray as to cause no material injury to existing water rights. The issuance of this permit does not ensure that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. Approved pursuant to CRS 37-92-602 (3)(b)(I) and the policy of the State Engineer for appropriation of ground water tributary to South Platte River system. The use of ground water from this well is limited to drinking and sanitary facilities as described in CRS 37-92-602(1)(c), for a commercial business. Water from this well shall not be used for lawn/landscape/greenhouse irrigation, domestic animalllivestock watering, or for any other purpose outside the business building structure(s). The pumping rate of this well shall not exceed 15 GPM. The annual amount of ground water to be withdrawn by this well shall not exceed 1/3 acre-foot (108, 600 gallons). Approved as the only well on a tract of land of 243 acre(s) described as the SE11M and the E1/2 of the SW1/4 of Sec. Ill, Twp. 1 N, Rng. 66 W, 6th P.M., Weld County, reference attached exhibit "A". The total depth of the well shall not exceed 150 feet, which corresponds to the base of the Upper Arapahoe aquifer. At a minimum, plain casing shall be installed and grouted through all unconsolidated materials and shall extend a minimum of ten feet into the bedrock formation to prevent production from other zones. 9) The return flow from the use of this well must be through an individual waste water disposal system of the non -evaporative type where the water is returned to the same stream system in which the well is located. 10) A totalizing flow meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be maintained by the well owner (recorded at least annually) and submitted to the Division Engineer upon request. 11) This well shall be constructed not more than 200 feet from the location specified on this permit. NOTE: This permit will expire on the expiration date unless the well is constructed by that date, A Well Construction and Yield Estimate Report (GWS-31) must be submitted to the Division of Water Resources to verify the well has been constructed. An extension of the expiration date may be available. Contact the DWR for additional information or refer to the extension request form (GWS-64) available at: httplivirww.waterstate.co.us APPROVED IDO Receipt No. 3676450 Z7kA a4&12 State Engineer , By DATE ISSUED 10-05-2016 EXPIRATION DATE 10-05-2018 Application Number: Owner Name: Site Address: WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT 1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth.org Septic Permit New SP -1700178 DISCOVERY DJ SERVICES 4501 CR 35 FORT LUPTON, CO 80621 App Type: Health\Commercial\New OWT \Septic JOSH BRUCE Parcel Number: Legal Desc: 4041 BRUIN BLVD FREDERIC, CO 80504 147111000009-09533033 LEASEHOLD INT SWSE 11 1 66 GRISWOLD 26N-11 HZ Work Description: OPERATIONS BUILDING EHS SEPTIC GENERAL: Application Status: Final Pending Applied Date: 06/1312017 Intake Person: SCERRILLO Permit Expiration Date: Associated Disaster Permit Parcel Acres Private Water Supply Permit Reference Number Public Water Supply Waive Fees No 243.35 303055 No No Hs-ollii Adrn[ IsIroI1on VIIaI R n ¢rds rink). 1 /0 3O4 A41 f} Fox: 970-304-6412 Public Health ; S crvics's felt': 9/O 3O4 64;20 Fox: 97O -3O4-6.{16 �rw�Qnen nfot N fiatth �s�rvlcs�s T+ irt: 910 )01, 6415 rcn: 9?O-.O1-64 Communication, Education l Planning Toby Irt; 97C) ,,304 47O F 3E 970-W4-6452 trr►.rg.ncy PrisparecintsF & frispont. Tarr; { / G, 04.6470 Fax, 970-K4-.6452 Page 1 of 3 Public th EFTS PERC TEST (SITE) : Engineer Design Required Engineer Job Number Ground Slope In 100 Year Flood Plain Limiting Zone Feet Limiting Zone Qualifier Long Term Acceptance Rate Profile Pits Slope Direction Soil Type Soil Type Suitable Treatment Level Yes 17-7084 1.5 No 8 Greater Than 0.35 2 East 3 Yes Level I SEPTIC SIZING INFORMATION: From the application information supplied and the on -site soil percolation data the following minimum installation specifications are required according to the Engineer's evaluation: Engineer's Specified Installation Recommendations: Engineer Design Absorption Area Specified Engineer Design Chamber Specified Engineer Design Number of Chambers Specified Engineer Septic System Design Type Specified Septic Tank Size 480 Quick 4 Standared or High Capacity 40 Chambers -Bed 1000 CONDITIONS: Description: Permit Conditions Comment: Construct onsite wastewater treatment system according to Engineer design. Septic tank must be at least 50 feet from any well. Soil treatment area must be at least 100 feet from any well. Building sewer or effluent lines must be 50 feet from any well unless the lines are encased. Keep vehicle traffic off of onsite wastewater treatment system. All easements shall be verified prior to installation of septic system. Engineer designed onsite wastewater treatment system must be inspected by the design engineer prior to as clef I I i rig . Engineer needs to approve type of replacement soil used. All Weld County regulations are applicable INSPECTION RESULT: Description: Site Status: Approved to Issue Comment: RitcsIhay AdmFni'shotlon Veal R.cards hele: 910 204 AC ) Fox: 970-204-64)2 Public Health Clinical Services Tele; 910 304 647C Pak: 970-.2.04-64 )6 Envirotnwnluk NeaNb sl c Tole,; 970,30444i 5 Fax: 970-304•64?'I Carnnvviiun, Ed ucn R Planning Toll": 9 7O..304-6470 Fax: 970-304-6452 Emergency Preparedness i Response 971),304. 6410 Fax. 4?C-3e4-6432 Page 2 of 3 NOTICE This permit is granted temporarily to allow construction to commence. This permit may be revoked or suspended by the Weld County Department of Public Health and Environment for reasons set forth in the Weld County Onsite Wastewater Treatment System Regulations including failure to meet any term or condition imposed thereon during temporary or final approval_ The issuance of this permit does not constitute assumption by the department or its employees of liability for the failure or inadequacy of the sewage disposal system. This permit is non -transferable and non-refundable. Before issuing final approval of this permit the Weld County Department of Public Health and Environment reserves the right to impose additional terms and conditions required to meet our regulations on a continuing basis. Final permit approval is contingent upon the final inspection of the completed system by the Weld County Department of Public Health and Environment. James Taloumis June 22, 2017 Environmental Health Specialist Date Page 3 of 3 Heats' Ad minishaflon Vital R' :ocds 'el : 9/0 :10# A410 Fox; 970-304-6412 Public Mn$h & gnat $trvien rale: 970 304 6,420 ax: 'flQ- 4.6416 Invionmintal Health Servieet Toilet: 970'3O4 P 64 I $ For r 970-304-6411 Cornnwnicu$ . Education & Plannln g TOE 9'70.304.6470 fax: 'x'70404.6452 Emergency Prepixeciness S hhsponne i fl,; ' O.304,6470 Fax: 970 -3C4 -64S2 Publla8eal!'h Hello