HomeMy WebLinkAbout760452.tiff 1 [Y 3/43 FICE OF BUILDING INSPECTION \ ` PHONE 13031 353-2212 EXT.229&230 1516 HOSPITAL ROAD GREELEY,COLORADO 80631 i .s.z7 vivo O Y sW 7 COLORADO January 23 , 1976 Virgil Sharp Rt . 1 Box 113 Gill , CO 80624 Dear Sir : As we have not received a copy of the complaints that you have listed , 1• e have proceeded on the major violations in the construction of your home that we noted in our inspection . We have sent you a copy of these items . We have eliminated the following for reasons given below : 1 . Nuts on foundation bolts , pressure from the nuts • facilitate the straightening of the mud sill . Any winds that would move the home after completion on the walls would not be stopped from causing damage by the nuts being on the bolts . 2 . Dryer vent not screwed together , minor home maintenance . 3 . No corner bracing in north east corner of garage , corners braced in north west corner , overhead door set and unit all sided , do not feel the installation of bracing at this time would accomplish anything . • 4 . Crack between home and stoop , believe caused by normal shrinkage and a slight settlement , believe caulking is minor home maintenance . 5 . Ventilation in garage , not required per Sec . 1502 . Sincerely; ,/ / i %J0SEP,Ji E . JARVIS P . E . • Director JEJ : kpe CC : N . Carlson , Weld County Commissioner WELD COUNTY COMMISSIONERS GLENN K. BILLINGS ICTOR JACOBUCCI 760452 ROY MOSER f') PLAY 3 w -..-.7%-. ` y ` -TICE OF BUILDING INSPECTION _ PHONE (303) 353-2212 EXT.229&230 1516 HOSPITAL ROAD qr GREELEY,COLORADO 80031 ��, rite CiiTho � COLORADO January 23 , 1976 Court Square Investment Company 301 Spruce St . Suite #301 Boulder , Colorado 80302 Attn : James H . Tull , President Arthur Spence Gentlemen: Due to a complaint by Virgil Sharp , the owner who purchased a home built by your company on Building Permit #3483 issued May 16 , 1974 , we made an inspection and found the following : 1 . The home was built and occupancy was given without the final inspection . This is a violation of the Building Code and is classed a misdemeanor UBC - 1973 Section 304 Sec . ( d ) Item 4 and Sec . 205 . 2 . No flashing between the house and garage roof and over the front door area causing water leaks in the home ( Sec . 3208) . 3 . No ventilation in crawl area ( Sec . 2517 , Sec . 6 ) . 4 . Access to crawl area blocked by furnace and Hot Water installation ( Sec . 2517 , Sec . 2 ) . 5 . One-half inch ('-i" ) sheet rock between garage and home , no evidence of fire rating ( Sec . 503 sec . ( d ) 4 ) . 6 . No step a,nd landing to garage floor 10 'z" rise ( sec . 3303 sec . ( h ) . 7 . Wood around chimney tight to masonry , code requires two inch ( 2 " ) clearance ( table 37 -B ) . 8 . No evidence of caulking around windows , flashing on top of Hick ledge and side of chimney next to home . Will need to be caulked ( Sec . 1707 ) . WELD COUNTY COMMISSIONERS GLENN K. BILLINGS VICTOR JACGBUCCI ROY MOSER Court Square Investment Company January 23 , 1976 Page Two 9 . Finish grade of earth too high on siding . Minimum six inch ( 6 " ) clearance required between siding and dirt . ( Sec . 2517 , Sec . 7 ) . These are basic code violations and not conditions caused by use or depreciation due to time . These are conditions that would have required corrections at the Final Inspection had it been called for . We therefore request that these items be corrected in the near future to conform with the Building Code , UBC 1973 . Please advise this office of your schedule for corrections by February 6 , 1976 . Sincerely , n/J0SEPHE . JARVIS P . E . Director JEJ : kpe CC : N . Carlson , Weld County Commissioner Virgil Sharp • A COURT-SQUARE INVESTMENT Go. A LAND INVESTMENT&MAN:\DEMENT CORPORATION 1901 Jfitrace, £eet . 10:0 801 JAMES H.TULL V 9 10 ilia '"/"' ieraeL 80`902 PRESIDENT </ e1. C%• R( '? TELEPHONE (3O3) 449-291 I Cr) FEB 76 F ) February 5, 1976 Weld County Colorado Office of Building Inspection RE: Building permit #3483 1516 Hospital Road Greeley, Colorado 80631 Attn: Joseph E. Jarve, P.E. Director Dear Sirs: We are in receipt of your letter dated January 23, 1976 in reference to building permit #3483 and alleged code violations stated in your letter. We wish to take this opportunity to state our position in this matter. We believe there was a final inspection given even though not evidenced by a certificate of occupancy. At the time the house was constructed and inspected it was not an automatic thing for Weld County to issue a certificate even when requested. We experienced having to drive to Greeley to get certificates. For this reason we do not believe that because there. is no record of a certificate there was no final inspection. Almost without exception the items listed in your letter are items that should have been inspected during construction and not only upon final completion of the building. Item #7 of your letter we believe is specifically unreasonable as Weld County did not hcgin enforcing this requirment until approximately one year ago and after the building in question was finished. It is interesting to note that even to this date no other county, town, or city in which we build, including Larimer and Boulder counties, the cities of Boulder and Lafayette, enforces this code in 'the same manner as Weld County does. > We believe this whole situation is unreasonable and unjust and is being applied in a discriminatory manner. We have not been notified by the owners in any form of their complaint or any request for repairs or warranties to be performed on the items listed in your letter. We request that you review our position and that of the county and expecially in respect to the county's procedures existing at the time of construction. We will await your reply before taking any further action. Sincerely, COURT SQUARE INVESTMENT COMPANY Art Spence AS:cs ••• FICE OF BUILDING INSPECTION "�;�.:~ • PHONE (303)353-2212 EXT.229&230 ;,. 1516 HOSPITAL ROAD GREELEY,COLORADO 80631 TA 11) 11 COLORADO February 11 , 1976 Court Square Investment Company 1301 Spruce St . Suite #301 Boulder , Colorado 80302 Attn : Art Spence RE : Building Permit #3483 Dear Sirs : We are in receipt of your letter of February 5 , 1976 in which you have taken exceptions to our letter of January 23 , 1976 . As you no doubt noted in our letter , there was no mention of a Certificate of Occupancy . We also note that you realize a final inspection is required under Code . This particular job did not have a final inspection. See copy of enclosed permit and records of inspection . The list of violations are a type that are generally completed between the framing stage and the final inspection . The siding could possibly be installed before the framing inspection . As stated , if a final inspection had been called for and the inspection made , these violations would have been noted and the correction of same could have been made before occupancy . In reference to item #7 , Table 37B _ Chimney Serving Residential Type Appliances , clearly indicates on interior installation , the Code requires a 2" clearance of combustible materials . In this project you are , as stated , "tight " to the chimney , no clearance . Weld County has adopted the UBC-1.973 and has enforced this section since 1973 . What the other towns or counties enforce or don ' t enforce within the Code is not our concern . We are sure if you check in your Code Book ( IIBC-1973 ) you will see that this question leaves no other interpretation . WELD COUNTY COMMISSIONERS GLENN K. BILLINGS NORMAN CARLSON VICTOR JACOBUCCI • JUNE STEINMARK ROY MOSER Court Square Investment Company 1301 Spruce St . February 11 , 1976 Page Two The owner states that she and her husband have at various times talked to Mr . Tull and to you personally about these problems and to date , they have not received any satisfactory replies . We are enclosing a letter that the Sharp ' s sent to the commissioners and a list of problems that the Sharp ' s are objecting too . We believe at one time someone from Tradition Homes called our office and stated that our office was discriminating against that company . We seem to detect a similar feeling in your letter of February 5 , 1976 . To let you judge your own workmanship , we are sending you the inspection reports on the 3 homes that Tradition Homes is building with special emphasis on the framing reports . Please note the pattern of work to be corrected , particularly in reference to flashing . This work follows neither the Code nor standard acceptable practice in construction for residential work . In these cases , it is not discrimination , it is just poor workmanship . As to the Sharp project , we cannot see any unreasonable , unjust or discrimination being applied as the Code Violations that we have listed are there to see on the home . They can be checked in the Code Book . The records show that the . final you refer to has not been made . We request you review your position in regards to the above violations and advise us of your decision either to correct same , or, if you do not intend to do so by February 20 , 1976 . Sincerely . (7 --7 ,,// ! i - . p d p NN 'IS P . E . y W , 't .!1 61 p . 1 'D G 3k i .g.a.,. .7 l S 3 apa .s .0 'a1 W 9 W R.. N f Et i u ` U ', . .p { gOJOf e0i.Ic l '?1 j O i7 V ;1 Q 3 �p .. s3 {a� G O W W W El' . O h N W t00 ❑ �� � � h Dc re z P9 farm 3811, 1m. 1975 RETURN RECIPE Rf gISTERED, INSURED AND CERTIFIED MAIL HOME OF VIRGIL AND LORRAINE SHARP (Builders - court square) 1. Fire wall between garage and home 2. No screen or louvre in garage 3. Foundation bolts do not have top on, or 6' apart 4. Foundation plates are not treated boards 5. Wrong type of nails used on sideing 6. Not enough nails on sideing to hold. 7. No foundation venelation in crawl space 8. Wrong type of outside faucet or no valve to close faucets 9. No flashing between garage and house 10. Step into garage to high 11. Front stoop is sinking because it was not attached to house 12. Improper siding on north east corner of garage 13. No slant (away from window) on bottom level windows 14. Fireplace brick touches wooden structure in garage 15. Flue opening too small 16. Chimney is not 2' higher or 10' away from top of roof r' G,1 Hello