Loading...
HomeMy WebLinkAbout20191255.tiffUSE BY SPECIAL REVIEW USR APPLICATION DEPARTMENT OF PLANNING SERVICES * 1555 N. 17TH AVENUE * GREELEY, CO 80631 www.weldgov.com * 970-400-6100 * FAX 970-304-6498 FOR PLANNING DEPARTMENT USE: AMOUNT $ APPLICATION RECEIVED BY DATE RECEIVED: CASE # ASSIGNED: PLANNER ASSIGNED: USR18-0 119 Parcel Number*: C 41 " SI- _o 3 Address of site: Legal Description: SC /21 New Recorded Exemption r Zone District: A Acreage: sc. Lr Flood lain: FEE OWNER(S) OF THE PROPERTY: 1►li dna- Name: Company: Phone #: c‘ v‘ y (*A 12 digit number on Tax I.D. information, obtainable at www.weldgov.com). Section: 2S Township: % N Range: W eological Hazard: YQN a Airport Overlay: YQN Street Address: 11 City/State/Zip Code: i Peet- I Co 80 c Name: Email: ft - Company: Phone #: Street Address: Email: City/State/Zip Code: Applicant: Name: Expedition Water Solutions Colorado LLC Company: Phone #: Street Address: Email: 2015 Clubhouse Drive, Suite 201 City/State/Zip Code: Greeley, Co 80634 APPLICANT OR AUTHO, IZED AGENT: (See below: Authorization must accompany all applications signed by Authorized Agents) Name: LI: (%) c \1/40,\"; 6: i rni 3 iel&r1/4 Company: e .xr s -f, Lint _ ., l,,.4 6. Phone #: '7 _ r - Email: Street Address: I City/State/Zip Code: /gin. - -c b /14 1 00 PROPOSED USE: c‘ic: S he -ft 0)11 I -7\x_ li. I e't C. A ta l (We) hereby depose and state under penalties of perjury that all statements, proposals, and/or plans submitted with or contained within the application are true and correct to the best of my (our)knowledge. Signatures of all fee owners of property must sign this application. If an Authorized Agent signs, a letter of authorization from all fee owners must be included with the application. If a corporation is the fee owner, notarized evidence must be included indicating that the signatory has to legal autho'ty to sign '• r the corporation. g Signature: Owner or Authorized Agent Date Signature: Owner or Authorized Agent Date -. L \vAv Print Name ,S keseNt .v Print Name Rev 4/2016 DEPARTMENT OF PLANNING AND BUILDING DEPARTMENT OF PUBLIC HEALTH AND ENVIRONNMENT 1555 NORTH Timm AVENUE GREELEY, CO 80631 AUTHORIZATION FORM (t4aefi k l TV\ct1 Skt Hcler permission eiris (Owner - please print) (Authorized Agent — please print) to apply for any Planning, Building or Septic permits on our behalf, for the property located at (address or parcel number) below: 124O1* rttet, O57rSOOOO5a3_aa_ Legal Description; � E of Section 429C, Township + N, Range Cop_ I W Subdivision Name: Lot Block Property Owners Information: Address: 6001 tt.,) s+ CreeIej Cwo eocaiy 3q 5-5-q5 Phone: �7n �PE-mail; Authorized Agent Contact Information: Address: fip q '� -3 EISS K �S � 1 tt ��'V � �! � .. CO __5046-.1 Phone: j705T3 7-2occ, __ . C'1YIC7�I. �&erflS ZS;nn ai/Yccr� Correspondence to be sent to: Owner, 0 Authorized Agent a Both Ell by Mata Email I51 Additional Info: Owner Signature: Owner Signature O144)) Date: I U - z 3.- ig 0A-ut glieteeKnivu, (p -z3 -lg __, Date: DEPARTMENT OF PLANNING AND BUILDING DEPARTMENT OF PUBLIC HEALTH AND ENVIRONNMENT 1555 NORTH 17TH AVENUE GREELEY, Co 80631 AUTHORIZATION FORM I, Jim Goddard President of Expedition WaterSolutions; give permission to Eric Wernsman (Owner — please print) (Authorized Agent — please print) to apply for any Planning, Building or Septic permits on our behalf, for the property located at (address or parcel number) below: .Parcel # 046525000053 Legal Description: Part of SE 1/4 of Section 25 , Township 9 N, Range 61 W S ubdivision Name: Lot Block Property Owners Information: Address 2015 Clubhouse Drive # 201 Greeley Colorado 80634 P hone: 970-515-6950 E-mail: jgoddard exc ed' tion- ater.cQm Authorized Agent Contact Information: Address 16493 Essex Rd South Platteville Colorado 80651 P hone: 970-539-2656 E -Mail eti erns26 gmaLL _com Correspondence to be sent to: Owner Authorized Agent Bath / by Mail_ _ Email Additional Info EWS #8 Site Owner Signature: Ciffelier Date: Owner Signature: Date: USE BY SPECIAL REVIEW (USR) QUESTIONNAIRE Answer the following questions on a separate sheet. If a question does not pertain to your use, please respond with "not applicable". For assistance with some of these questions see this website: http://www.po.weld.co.usi epartments/Plynnin oning/LandUseApplicationsAssistance/ApplicationAssistanee.html Planning Questions: 1. Explain, in detail, the proposed use of the property. The site will be used for a Class II salt water injection well facility. The site will have an 80' x 100' steel building that will contain the office area and the injection pumps. There will be a concrete tank containment area that will have up to 35 steel and/or fiberglass tanks that will be used for salt water processing. There will be a concrete truck unload pad that will also provide containment. A pipeline will be constructed to deliver water to the site in there will be very little truck traffic to the facility. The USR map shows the initial construction to consist of (2) spaces for trucks to unload water. The USR map shows expansion to (6) spaces but that expansion is not anticipated at this time. 2. Explain how this proposal is consistent with the intent of the Weld County Code, Chapter 22 of the Comprehensive Plan. The injection well facility will be placed on a site that will have no negative affect on surrounding agricultural uses. There is a gas plant owned by Sterling Energy along the west property line. 3. Explain how this proposal is consistent with the intent of the Weld County Code, Chapter 23 (Zoning) and the zone district in which it is located. he use will be permitted by a Use by Special Review. 4. Describe what type of land uses surround the site. Explain how the proposed use is consistent and compatible with surrounding land uses. All the adjoining properties are used for agricultural purposes. There is pasture land to the north, south and east. There is a gas plant owned by Sterling Energy along the west property line. 5. What are the hours and days of operation? (e.g. Monday thru Friday 8:00 a.m. to 5:00 p.m.) The facility will operate 24 hours a day 365 days a year 6. List the number of full time and/or part time employees proposed to work at this site. There will be up to 10 full time employees on the site every day. 7. If shift work is proposed include the number of employees per shift. The employees will be split over 3 shifts a day. 8. List the number of people who will use this site. Include contractors, truck drivers, customers, volunteers, etc. There will be less than 20 semi trucks with trailers a day come to the site. There may be up to 20 passenger car trips to the site a day. If the truck traffic levels increase, Expedition is happy to revise the USR application in the future. If this is a dairy, livestock confinement operation, kennel, etc., list the number and type of animals. 10. Describe the type of lot surface and the square footage of each type. (e.g. asphalt, gravel, landscaping, dirt, grass, buildings) . r he site is planned to have 8000 sq. ft. of building, 55,300 sq. ft. of gravel, 43,380 sq. ft of concrete and the remainder of the 20 acre site to remain as reclaimed to native grasses, farm and or ranch land. 11. How many parking spaces are proposed? How many handicapped (ADA) parking spaces are proposed? There is 1 ada space planned and Y non ada spaces proposed. 12. Explain the existing and proposed landscaping for the site. There is no landscaping planned at this time due to to the very rural nature of the site. All disturbed areas that are not planned to covered will be re -seeded with native grasses. 13. Describe the type of fence proposed for the site (e.g. 6 foot chain link with earth tone slats) A pipe gate may be installed at the access point at least 75' off the edge of CR 100 14. Describe the proposed screening for all parking and outdoor storage areas. If the site is located in a floodplain outdoor storage is restricted. There is no screening planned for the site. The site is located on an unprinted flood plain panel 08123C1050E Zone D 15. Explain any proposed reclamation procedures when termination of the Use by Special Review activity occurs. If the site is abandoned, the injection well(s) and containment areas will need to be abandoned per COGCC regulations. 16. Who will provide fire protection to the site? Pawnee Fire District 17. List all proposed on -site and off -site improvements associated with the use (e.g. landscaping, fencing, buildings, drainage, turn lanes, etc.) and a timeline of when you will have each one of the improvements completed. The overlot grading will begin after USR approval. It will take approximately 6 months to complete the grading, concrete work and building construction. The seeding will be completed by November 2019. Engineering questions: 1. Describe how many roundtrips/day are expected for each vehicle type: Passenger Cars/Pickups, Tandem Trucks, Semi-Truck/Trailer/RV (Roundtrip = 1 trip in and 1 trip out of site) 20 roundtrips per day passenger cars 20 roundtrips per day Semi-Truck/Trailer 2. Describe the expected travel routes for site traffic. Traffic will enter on the south side of the site, travel north to the unload pad and then east and south and back west and finally south to site entrance/ exit point. Describe the travel distribution along the routes (e.g. 50% of traffic will come from the north, 20% from the south, 30% from the east, etc.) It is anticipated that 50% of the trucks will go east on CR 100 to CR 390 and to 50°k will go west on CR 100 to CR 89. 4 Describe the time of day that you expect the highest traffic volumes from above. The highest anticipated traffic volume will be from 9:00 am to 10:00 am 5. Describe where the access to the site is planned. The site access is planned off CR 100 at a distance of 3200' east of CR 95 6. Drainage Design: Detention pond summarized in a drainage report is required unless the project falls under an exception to stormwater detention requirements per code section 23-12-30 F.1. A. Does your site qualify for an exception to stormwater detention? If so, describe in a drainage narrative the following: 1. Which exception is being applied for and include supporting documentation. 2. Where the water originates if it flows onto the property from an offsite source 3. Where it flows to as it leaves the property 4. The direction of flow across the property 5. If there have been previous drainage problems with the property B. Does your site require a stormwater detention pond? If so, the following applies: 1. A drainage report summarizing the detention pond design with construction drawings and maintenance plan shall be completed by a Colorado Licensed Professional Engineer and adhere to the drainage related sections of the Weld County Code. Drainage report and drawings will be provided 2. The drainage report must include a certification of compliance stamped and signed by the PE which can be found on the engineering website. A stamped copy and certificate of compliance will be provided with the final accepted copy. 3. A general drainage report guidance checklist is available on the engineering website. More complete checklists are available upon request. Environmental Health questions: 1. What is the drinking water source on the property? If utilizing a drinking water well include either the well permit or well permit application that was submitted to the State -Division of Water Resources. If utilizing a public water tap include a letter from the Water District, a tap or meter number, or a copy of the water bill. A well will be applied for. 2. What type of sewage disposal system is on the property? If utilizing an existing septic system provide the septic permit number. If there is no septic permit due to the age of the existing septic system, apply for a septic permit through the Department of Public Health and Environment prior to submitting this application. If a new septic system will be installed please state "a new septic system is proposed". Only propose portable toilets if the use is consistent with the Department of Public Health and Environment's portable toilet policy. A septic system design will be provided with USR approval. 3. If storage or warehousing is proposed, what type of items will be stored? A 55 gallon drum of scale inhibitor and a 55 gallon drum of biocide will be stored. 4. Describe where and how storage and/or stockpile of wastes, chemicals, and/or petroleum will occur on this site. The biocide and scale inhibitor will be stored in the pump building which has containment provided within the building. The oil that is recovered from the filtering process will be stored in a fiberglass tank that will be inside the tank containment area. 5. If there will be fuel storage on site indicate the gallons and the secondary containment. State the number of tanks and gallons per tank. A 300 gallon diesel tank will be on site in the tank containment area. 6. If there will be washing of vehicles or equipment on site indicate how the wash water will be contained. Wash water from tanks and or vehicles will be contained on the truck unload pad. The water will drain into the injection well system. 7. If there will be floor drains indicate how the fluids will be contained. Floor drains will drain into the injection well system. 8. Indicate if there will be any air emissions. (e.g. painting, oil storage, etc.) If the USR is approved EWS will attain an Apen Permit for the facility. 9. Provide a design and operations plan if applicable. (e.g. composting, landfills, etc.) 10. Provide a nuisance management plan if applicable. (e.g. dairies, feedlots, etc.) N/A 11. Additional information may be requested depending on type of land use requested. Building questions: Jose Gonzalez 970-353-6100 1. List the type, size (square footage), and number of existing and proposed structures. Show and label all existing and proposed structures on the USR drawing. Label the use of the building and the square footage. An 8000 square foot metal building will be constructed that will enclose the pump buildings and office areas. 2. Explain how the existing structures will be used for this USR? There are no existing buildings on the site. 3. List the proposed use(s) of each structure. Please see above Weld County Public Works Dept. 1111 H Street P.O. Box 758 Greeley, CO 80632 Phone: (970)304-6496 Fax: (970)304-6497 Property Owner Name Michael and Mary Krier Cornpang Address 6001 W 21st St city Greeley State CO zip 80634 Phone Fax. E-mail Parcel Location The access is onWCR 100 Nearest Intersection: WCR 100 & WCR 5 Dist. from Intersection (approx. in ft.) 3200' East Parcel Number(s) 046525000003 Section/Township/Range 25/0/61 Total # of Existing Accesses to parcel 0 Proposed Use ❑ Temporary (Tracking Pad Required) (U) n Small Commercial (#) ❑ Field (Agriculture Only) (#) ACCESS PERMIT APPLICATION FORM Authorized Agent/Applicant (if different from Owner) Name Eric Wernsman Company Wernsman Engineering and Land Development Address 16493 Essex Rd S City Platteville p State CO Zi 80651 Phone 970-539-2656 Fax E-mail eJwerns25@gmaiLcom Existing Count v Road Surface Information Asphalt Gravel iff Treated Other Proposed Access Information Culvert Size & Type (15" CMP/RCP min.) 15" MP Materials used to construct access Access Construction Start Date Access Construction Finish Date c Single Residential L#) ❑ Oil & Gas (tt) tz Large Commercial (#) ) ❑ Industrial (#) ❑ Subdivision O#1 Is this access associated with a Planning or Building Department Process? i USR/MUSR ❑ RECX/SUBX E. PUD D WOGLA ❑ COMPLEX (IA required) a Other Planning/Building Department case If Required Attached Documents - Traffic Control Plan (a generic plan can be found at https://www.weldgov.corn/departments/public works/permits!) During the review process it may be determined that a right-of-way use permit will be required as well. - Certificate of Insurance (with "Weld County, Colorado" listed as the certificate holder & as an additional insured) Access Pictures (from the left, right, into & out of the access — N, 5, E, & W) - Access Authorization Form (Not required if the application is signed by the landowner.) Fee schedule (to be determined by permitting agency) - $75 each access point: Temporary, Small Commercial, Oil & Gas, Single Family Residential - $150 each access point: Industrial, Large Commercial, Subdivisions - Field (Agriculture only): no cost Parcel Sketch (or provide an aerial on an add`I sheet) A- Existing Access L1- Proposed Access WCRZ,- T N trfts u Description of Work or Reason for Permit WCR itt raTh sit 1 U By accepting this permit, the undersigned Property Owner/Authorized Agent, under penalty ofperjury, verifies they have received all pages of the permit application; they have read and understand all the permit requirements and provisions set forth on all pages. By virtue of their signature the Property Owner/Authorized Agent is bound by and agrees to comply with all said permit requirements and provisions, all Weld caunty ordinances, and state laws regarding access construction. Signature Printed Name Signature Printed Name (In case of multiple Property Owners/Authorized Agents) er: Lie fiti S imieN Date ityierAl Date • Access Permits are good for 1 year from the date of issuance. Property Owner/Authorized Agent must obtain a new permit or request an extension if the construction of the access point is not completed in that timeframe. • Extensions are subject to approval by Public Works * County regulations on road access can be found in Article V of Chapter 12 of the Weld County Code. •r 'a "-ii 4 4 - `. a•. . a -. wi j f" f. r r p •}. .a;.�R} . r.•r o- '.S g. ..4t v r it.r . IL y �y t r M E �'1` rL, r J 6 -1 • . , + tl 1-r ��r n r. F lS e w r '_I,f'.. rCd +„ ti r-' t" . #. 4 �'�e a!;c::: a - `y ' .�•-`�.1$ eu r- .. .e �iy� t •i 'a r`aM=a,.t 4i'-�'a:h..11:''fr� ^" •;��. �: CI r ti • `,1� r , 'V ti r, DP`.- -P•.y f. iat •ir -Jq�r F �-"_PP •� ti.t '4 ,L Sr i "4 L rl•M Ji t • t s[ - -•. U. T • it. "•.i rp 'Sr; • rA 'k t^•�\1 ;wit; Pr . .rr-: ire:• r • a• *: • ar-7 - aJ. * s r .r•. • • ..... 1•_ • w e f •. '•.l it r' - •i-�-•• 4 .Y' r yam'• . i.• _. .�.' :�C - • I t .1 • T la I ►[ " 1 C • ' . 41 :a + i •• r • n 2 P _ Y.Y .. .r_ C. r - r• r s r .• a.- , f - '' • . V. • •: "c •V-•. • ' _ e- �'. • `r it -.• Ili i }. { . • .• • - • J•. •.t +• -. r'-' •. •• Tr4. .. . i r .. iir r• _, _e .j s.Ls14:_ ta .j, ra ill - r .r� rA._r. '1• r •'•i.- ` +,.-r i.r a; W a .4". r. : i. •t r s Ii 4` `'[' - " 'a a• • - S: ' _,�e.�. a•` 1. •ti L 9. b r'a'<• 4- v.�•ti • e 4 f fr '•f •. •' Waste Handling Plan, A dumpster will be on site for normal business refuse and will be emptied weekly, Waste will be disposed of at Waste Management North Weld Landfill 4000 Weld County Road 25 Ault Colorado 80610 Phone Number 866-482-6319 Dust Abatement Plan During the construction phase of the project Expedition Water Solutions will utilize water trucks to maintain dust suppression. The storm water management plan will be followed to mitigate soil erosion during the construction phase. After construction is completed the site will be stabilized using native vegetation and compacted gravel surfaces. Vegetation will not be allowed to grow over 12" high. Additionally Expedition Water Solutions will maintain the gravel drives and entrances. A water truck will be provided as necessary to maintain dust suppression. WERNSMAN ENGINEERING AND LAND DEVELOPMENT October 26, 2018 Hayley Balzano Weld County Public Works P.O. Box 758 Greeley CO 80632 ERIC WERNSMAN 16493 ESSEX RD PLATTEVILLE CO 80651 RE: Preliminary Drainage report and plan for Expedition Water Solutions EWS #8 Site on CR 100 Dear Hayley Attached is the Preliminary Drainage Report and Plan for the EWS #8 proposed injection well facility. This report addresses both the on -site and off -site hydrology that affects or is affected by the proposed development. If you have any further questions or comments regarding this matter, please contact this office. I TrAt 4 t," Eric ' `�` ��� WerrrP .i ',E. " I hereby certify that this report for the drainage design f r the EWS #8 injection well facility was prepared by me (or under my direct siverv6sion) in accordance with the provisions of the Weld County Storm Drainage Criteria for the owners thereof" ountiuia 13,,i) RE 04,4) Registered Professional Enghnr State of Colorado No. 33371 Index Page 1-6 7-9 10 11-13 14 15 16-17 18 19 20 21 22 23-26 27 28 29 DRAINAGE REPORT NOAH POINT PRECIPITATION FREQUENCY ESTIMATES BASIN AND SUB -BASIN IMPERVIOUSNESS CALLS 100 -YR PEAK RUNOFF ALL BASINS SWALE CALCULATIONS SECTION A -A SWALE CALCULATIONS SECTION B -B SB2 CULVERT CALCULATIONS DETENTION VOLUME REQUIRED FAA METMOU DETENTION VOLUME PROVIDED WQCV ORIFICE AND REQUIRED VOLUME 10-YR HISTORIC RELEASE RATE ORIFICE EMERGENCY OVERFLOW CALCULATIONS NRCS S IL MAP AND INFORMATION FEMA MAP VIC!NITY MAP REFERENCES Genera! Description: The proposed site is located on the north side of County Road 100 which is is a gravel surfaced road. The western side of the site is approximately 2350' west of County Road 95. The western side of the site is next to a Natural Gas Compressor Station. The northern, eastern, and southern boundaries are adjacent to undeveloped agricultural pasture property. (Please see sheet Cl for a vicinity map.) The proposed site is located within the South East 1/4 of Section 25, Township 9 North, Range 61 West of the 6th Prime Meridian. The legal description for the property will be part of a Recorded Exemption that will be applied for in the future. There are no mapped major waterways, water holding areas or water resources on or adjacent to the property. The entire proposed parcel will contain approximately 20 acres. Approximately 4.85 acres of the property will be developed. The site is proposed to be an injection well facility with gravel and concrete drives, a steel building and native grass swales. The ground cover on the existing site consists of natural grasses and weeds. The soil type(s) present are Avar-Manzanola Complex, Manzanola clay loam, and Olney fine sandy loam. See NRCS soil report in the appendix for location of soil types. NRCS classifies most of the soils in hydrologic group "C" for runoff purposes. In the proposed condition, offsite flows will be able to enter the site from the west and the on -site channels will have the ability to pass the 100-yr events to the detention pond and pass them via the emergency overflow. Most of the runoff generated by the proposed development will be collected via sheet flows, swales, and directed toward the on -site detention pond. The remainder of the un-developed on -site flows will sheet flow un- detained to the east. This area does not contain proposed improvements. The detention pond is located in the eastern portion of the property and releases developed runoff through a staged outlet. A water quality capture outlet will release minor storm flows over a 40 -hour time period and a major storm orifice opening will release flows at a ten-year historic rate. The released flow will be directed south east towards the roadside ditch in CR 100. Drainage Basins and Sub -Basins: There is no Weld County Master Drainage Plan for this site at the current time. Wild Horse Creek lies to east about 6 miles. The closest major basin is the South Platte River Basin, which lies approximately 24 miles to the south. The site lies on unprinted FEMA map panel 08123C1050E. This project site is located within Flood Hazard Zone D on the FEMA map. There is an offsite basin Sub -basin 051 to the south west that drains onto the property. 051 is almost entirely undeveloped and contains approximately 32 acres and has an imperviousness of 2. The 100 -year runoff rate is 66.22 cfs. The on -site channels are designed to carry all of the offsite flows and route them around the site. There are is one on site basin (Si) that direct flows flow away from the site to the swale (Sec A -A). Si is generated entirely from undeveloped area flow and does not drain into the detention pond. Sub -basin Si contains 126 acres, has an imperviousness of 2 and represents the flows along the west side of the developed site. The 100 -year runoff rate is approximately 6.30 cfs. Sub -basin (52) contains all of the developed site runoff. Sub -basin S2 is located in the central and eastern portion of the site and contains 4.58 acres. S2 has an imperviousness of 56 and generates a 100 -year runoff rate of approximately 22.66 cfs. Drainage Design Criteria: There is no Weld County Master Drainage Plan or project master drainage plans for this site at the current time. The site is in a Non -Urbanizing Area of Weld County. Offsite and onsite undeveloped flows from the southwest side of the site will be routed around the site and will not be passed through the emergency overflow. Nearly all of the developed flows from the site will be routed to the detention pond. Using the NOAA Atlas 14 Volume 8 Version 2 an IDF table was generated. A one -hour rainfall depth of 1.23 inches, 1.50 inches, and 2.64 inches was determined fora 5 -year, 10 -year, and 100 -year event, respectively. The rational method was used to calculate runoff and release rates. The detention pond was sized using a 10 -year historic release rate. A water quality capture volume is designed within the pond to release minor storms over a 40 -hour period to maintain water quality. The on -site swale was sized to pass the 100 -year event. The runoff for specific design points was calculated by inputting the area, imperviousness, soil type, one hour precipitation values, slope, length of travel and conveyance into the peak runoff spreadsheet. Please see the corresponding peak runoff and feature design for each point. The release rate and developed runoff amounts were calculated using the rational method. The detention pond volume was determined using the Modified FAA Method with one exception. The discharge rate did not use the soil type value. The discharge rate was determined by finding the total historic runoff rate for the site and then dividing by the site area per Weld County recommendations. This value was then input into the detention pond spreadsheet to determine the volume required. Drainage Facility Design: The 100-yr storm volume required by using the Modified FAA method was determined to be 28,697 cubic feet. With a pond outlet invert of 5003.45, the 100 -year high-water elevation is 5005. The available volume provided is approximately 42,942 cubic feet. The additional volume may be used if future development occurs on the site. The water quality capture volume (WQCV) can be included in this volume per the Weld County Addendum to the Urban Drainage Manual. The minimum WOG/ allowed for the site is 0.142 acre-feet. (6185 cubic feet). The proposed detention outlet has an initial orifice plate to provide water quality capture volume with one 1-1/8" diameter orifice to release the water quality capture volume runoff. The top of the orifice plate is set at elevation 5004.57 to ensure that once the water quality volume is captured the storm water spills into the next stage of the inlet. The second orifice plate with a 4" high opening releases flow to an 18 -inch diameter corrugated metal pipe (CMP) that directs flows to the south. A 2' x 7' rip rap pad shall be placed at the end of the outlet pipe to assist with erosion mitigation within the roadside ditch. An emergency spillway is designed in the detention pond berm to allow on - site flows to leave the detention pond in the event that the pond outlet is clogged. The emergency overflow is provided at elevation 5005. The spillway base shall be a minimum of 25 feet wide and will limit the flow depth to 5-1/4" inches at a discharge rate of 22.66 cubic feet per second. A 8' X 41' Type "L" Rip Rap area is provided on the downstream side of the overflow for erosion protection. Swale Sec A -A collects all of the offsite flows Sub -Basin 051 that drain to the property from the south west and the onsite flows from Sub -Basin Si (54.55 cfs combined) and routes the flow around the site to undeveloped portions of the site. Sec A -A has a minimum slope of 0.6%. The manning's "n" is 0.040 which creates a 100 -year water depth of 2.16 feet and a Froude Number of 0.50. The swale outfalls onto native grass areas. Swale Sec B -B collects the flow from Sub -Basin 52 (22.66 cfs) and carries flow to the (3) 24" CMP culverts crossing the driveway. Cross Section B -B has a slope of 0.6%. The manning's "n" is 0.040, which creates a 100 -year water depth of 0.87 feet and a Froude Number of 0.44. The (3) 24" CMP culverts have an inlet elevation of 5003.91 and an outlet elevation of 5003.78. When the head water reaches elevation 5005.4 the culverts have the capacity to pass 23.98 cfs even if the detention pond is full. At the end of the pipes, a 12 foot by 8 foot bed of Type L riprap is placed to mitigate erosion. The spreadsheets included in the report detail the physical requirements to provide adequate drainage ways. Please refer to the spreadsheets for the specific design. Once the site vegetation has been re -seeded very little maintenance should be required for site operation. Care should be taken to keep trash and debris out of inlets and pipes to prevent excess water from building up on the site. If complete blockage would occur in the detention pond outlet the water would release through the emergency spillway. If blockages occur they should be immediately cleaned. All storm water pipes shall be kept clean to maintain full capacity. S Conclusions: The proposed site will control developer! storm water flows through an on - site detention pond. The allowable release rates from the detention pond include a water quality release rate that allows minor storm flows to release over a 40 - hour time period and a major storm release rate that is equivalent to the ten-year historic runoff rate. Off -site flows that drain toward the site are directed around the property. All of these storm water flows are conveyed off -site to the east. This report and design will meet the Weld County Code without any variances. This design should be more than adequate to prevent either on -site or off -site runoff flows from creating damage. The site is not part of any Weld County Master Drainage Plan. Please see the reference sheet for a complete list of references used for this design and report Drainage/ Site Maintenance Plan 1. Site shall be inspected monthly or after every storm event. 2. At all times any erosion that may occur shall be corrected as soon as possible to mitigate the chance of erosion leaving the site. 3. All culverts shall be inspected regularly and cleaned if necessary. 4. Any seeded areas that are not covered with vegetation shall be re -seeded and irrigated as necessary to establish permanent vegetation. 5. Snow should not be piled in swales or near detention pond outlet. NOAA Atlas 14, Volume 8, Version 2 Location name: Briggsdale, Colorado, USA* Latitude: 40.7131°, Longitude: -104.1429° Elevation: 4931.66 ft** * source: ESRI Maps ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES Sanja Perin, Deborah Martin, Sandra Pavlovic, Ishani Roy, Michael St. Laurent, Carl Trypaluk, Dale Unruh, Michael Yekta, Geoffery Bonnin NOAA, National Weather Service, Silver Spring, Maryland PF tabular I PE graphical I Maps & aerials PF tabular PD -based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Duration Average recurrence interval (years) 1 2 5 10 [ 25 50 100 200 500 1000 5 -min 0.258 (0.201-0.333) 0.314 (0.244-0.404). 0.413 (0.320-0.533) 0.504 •(0.388-0.652) 0.640 (0.483-0.869) 0.756 (0.554-1.03) 0.879 (0.622-1.23) 1.01 (0.688-1.45) 1.20 (0.785-1.76) 1.36 (0.859-1.99) 10 -min 0.378 (0.295-0.487) 0.460 (0.358-0.592) 0.605 (0.469-0.780) 0.737 (0.569-0.955) 0.938 (0/07-1.27) 1.11 (0.811-1.51) 1.29 (0.911-1.80) (1.01-2.12) 1.48 1.76 (1.15-2.57) (1.26-2.91) 1.99 X15 -min 0.462 (0.360-0.594) 0.560 ' (0.436-0.721) 0.738 (0.572-0.952) 0.899 (0.693-1.17) 1.14 (0.862-1.55) I 1.35 (0.989-1.84) 1 (1.11-2.19) 1.57 (1,23-2.58) 1.81 2.15 (1.40-3.14) 2.42 (1.53-3.55) 30 -min 0.625 (0.487-0.804) 0.759 (0.590-0.977) 0.997 (0.773-1.29) 1.21 (0.935-1.57) 1.54 (1.16-2.08) 1.81 (1.33-2 A7) 2.10 (1.49-2.93) (1.64-3.44) 2.42 (1.874.17) 2.86 3.22 (2.044.73) 60 -rain 0.769 (0.599-0.989) 0.931 (0.725-1.20) 1.23 (0.950-1.58) 1.50 (1.15-1.94) 1.91 (1.44-2.59) (1.66-3.09) 2.26 2.64 (1.87-3.68) 3.05 (2.07-4.35) 3.63 (2.37-5.31) 4.11 (2,60--6.03) 2 -hr 0.913 (0.719-1.16) 1.10 (0.868-1.41) 1.45 (1.14-136) (1.39-2.28) 1.78 2.28 (1.74-3.07) 2.71 (2.01-3.67) 3.17 (2.27-4.38) 3.68 (2.53-5.20) 4.41 (2.91-6.37) 5.00 (3.20-7.25) 3 -hr 0.990 (0.785-1.25) I 1.19 (0.943-1.51) (1.24-1.99) 1.57 1.92 (1.50-2.44) i 2.47 (1.90-3.31) 2.94 (2.20-3.97) 3.46 (2.50-4,76) 4.03 (2.79-5.66) 4.85 (3.23-6.96) 6.52 (3.56-7.95) 6 -hr 1.14 (0.915-1.43) 1.36 (1.09-1.71) 1.78 i (1.42-2.23) (1.72-2.73) 2.16 2.77 (2.16-3.68) 3.29 (2.49-4.39) 3.87 (2.82-5.26) I (3.15-6.25) 4.50 1 5.41 (3.64-7.68) i 6.15 (4.01-8,76) 12 -hr 1.33 (1.07-1.64) 1.58 (1.28-1.96) 2.03 (1.64-2.,52) 2.45 1 (1.96-3.05) 3.07 (2.41-4.00) I 3.60 (2.75-4.72) 4.16 (3.07-5.57) 4.77 (3.37-6.53) 5.64 (3.83-7.90) 6.34 (4.18-8.93) 24 -hr 1.56 (1.28-1.91) 1.83 (1.49-2.23) 2.29 (1.87.2.81) i 2.72 (2.20-3.35) 3.36 (2.66-4.31) 3,89 (3.00-5.04) 4.47 (3.33-5.90) i 5.09 (3.64-6.88) 5.97 (4.10-8.25) 6.68 (4.46-9.29) 2 -day 1.78 (1.47-2.15) 2.08 (1.72-2.52) 2.60 (2.14-3.15) 3.06 (2.51-3.72) 3,73 (2.97-4.71) 4.28 (3.33-5.45) I. 4.85 53.65-6.31) 5.45 (3.94-7.26) I. 6.30 (4.37-8.58) 6,97 (470-9.58) 3 -day 1.94 (1.61-2.32) 2.24 (1.87-2.69) 2.77 (2.30-3.33) 3.23 (2.67-3.90) 3.90 (3.14-4.89) 4.46 (3.49-5.64) 5.03 (3.81-6.50) (4.10-7.46) 5.64 6.50 (4.54-8.79) 7.17 . (4.88-9.80) -day (1,73-2.47) 2.06 (1.99-2.84) 2.37 2.91 (2.42-3.48) 3.37 (2.80-4.06) I 4.06 (3.27-5.05) 4.61 (3.63-5.80) 5.19 (3.95-6.66) 5.80 (4.24-7.62) 6.65 (4.67-8.95) 7.32 ' (5.01-9.95) 7 -day 2.36 (1.99-2.79) 2.72 (2.29-3.22) 3.31 (2.79-3.93) 3.82 (3.20-4.55) 4.53 (3.67-5.56) 5.09 5.66 6.25 7.05 7.66 (4.04-6.32) (4.34-7.18) (4.60-8.11) (4.99-9.36) (5.29-10.3) 10 -day 2.63 (2.23-3.09) 3.03 (2.57-3.56) 3.68 (3.11-4.34) 4.22 (3.55-4.99) I 4.96 (4.04-6.02) 5.53 (4.40-6.80) 6.10 (4.70-7.66) 6.68 (4.94-8.59) 7.44 (5.30-9.81) 8.02 (5.57-10.7) 20 -day 3.46 (2.98-4.03) 3.93 (3.38-4.58) 4.69 (4.01-5.46) 5.30 (4.51-6.20) 6.13 (5.04-7.33) 6.76 (5.43-8.18) 7,36 (5.73-9.12) 7.97 (5.96-10.1) 8.76 (6.31-11.4) I 9.34 (6.57-12.3) 30 -day 4,17 (3.61-4.81) 4.71 (4.08-5.44) 5.57 (4.80-6.44) 6.26 (5.37-7.27) 7.18 (5.94-8.51) 7.86 1 (6.37-9,44) 8.52 (6.68-10.5) 917 (6.90-11.5) 9.99 (7.25-12.9) 10.6 (7.51-13.9) 45 -day 5.05 (4.41-5.79) 5.71 (4.98-6.55) 6.76 (5.86-7.76) 7.56 (6.54-8.73) (7.17-10.1) 8.63 9.40 (7.66-11.2) 10.1 (7.98-12.3) 10.8 (8.19-13.5) 11.7 (8.51-14.9) 12.3 (8.75-16.0) 60 -day 5.79 (5.07-6.60) 6.58 (5.76-7.51) 7.81 (6.82-8.93) 8.76 (7.60-10.1) 9.96 (8.31-11.6) 10.8 (8.85-12.8) (9.18-14.0) 11.6 12.3 (9.37-15,2) 13.2 (9.64-16.7) 13.7 (9.85-17.8) 1 Precipitation Numbers (for a given bounds Please frequency (PE) in parenthesis are duration and average are not checked against refer to NOAA Atlas estimates PF estimates recurrence probable 14 document in this table are based at lower and upper interval) will be maximum precipitation for more information. on frequency analysis of partial bounds of the 90% confidence greater than the upper bound (or (PMP) estimates and may duration interval. less be higher series (PDS). The probability than the lower than currently that bound) valid precipitation frequency estimates is 5%. Estimates at upper PMP values. Back to Top PF graphical 1 PDS-based depth -duration -frequency (DDF) curves Latitude: 40.7131°, Longitude: -104.1429° Precipitation depth Precipitation depth (in) 14 a 6 2 0 _ c 5 o r4 r -I Duration NOAA Atlas 14, Volume 8, Version 2 ! 1 R • f INA • • Fe pm, RI R 25 50 100 200 500 1000 Average recurrence interval (years) f Created (GMT): Thu Oct 18 15:00.53 2018 Back to TQQ, Maps & aerials Small scale terrain 3km i 2mi i Are recurrence intaval (years) IMINNIIMInme 2 5 10 25 50 100 200 500 1000 Duration FFETSIIIN alenseelmi �i• 5 -min 10 -min t SR-mmn 'ire 60 -min 2 -hr 3 -hr 6 -hr 12 -hr 24 -hr 2 -day 3 -day 4 -day 7 -day 10 -day 20 -day !-- 30 -day 45 -day 60 -day Large scale terrain • r > rV car tin b • I f re" r i Cheyenne fi .44 ►ittitiCa+ l ins s *Greeley L ongrnon t a 100km z -s II 6t?rni-int, Ter M c� Fort cow o Greeley LAngtnent Boulder Large scale map Ch rr e r S BOmi l.ar• a scale aerial Back to Top US Department of Commerce National Oceanic and Atmospheric Administration National Weather Service National Water Center 1325 East West Highway Silver Spring, MD 20910 Questions?: HDSC.Questonsnoaa.gpv Disclaimer 9 Sub -basin Imperviousness EWS8 10/24/2018 081 Land Use Area (ft2) I (%) Impervious Area, Grass 1395278 , 2 Roofs 0 903 Concrete Surfaces 0 • 100 Driveways, Gravel 0 40 Wghtd Avg & Total Area 1395278 2 cres S2 ( All developed Areas) 32.03 Land Use Area (ft2) 1 (%) Landscape 59381 2, Roofs 8000 90 Concrete Surfaces ' 43380 100 Driveways, Gravel 55269 40 Detention Pond 45089 100 211119 56 Wghtd Avg & Total Area Acres 4.85 SI (Remain Undeveloped) Land Use Area (ft2) I (%) Landscape A , 98635. 2 Roofs 0 90 Concrete Surfaces 0 100 Driveways, Gravel 0 40 Wghtd Avg & Total Area a 98635 2 Acres 2.26 eTh {f I � rein -or co C I I Pi - O 04 It S V Fa, YI It CO W r 460 Delis of this color are for required user -input co Cells of this color are for calculated results based on overrides I 413 o O 74-0 co - En 10/24/2018 co W c 6-15 0 Q a J O I O t N I' tip .2 U) 0 int co a) mom eta C to co U C ea 513 C C= C II II py Ig P9 N p�Y E g 4.7 P E II Li Li); C'3 Channelized Flow Time tt (min) / , N . Channelized Flow Velocity Vt (f /sec) r o N co r O O} r 0 r - GO N r 1o13eJ aaueAenuo3 SOIN r CC'J a r •avel) Flow Channelized Flow Slope St (Mt) O 6 O 6 O 6 O 6 DIS Elevation (ft) (Optional) U/S Elevation (ft) (Optional) i Channelized Flow Length Lt (ft) O J'1N''� 4 s ' 3487.00 (u!w) awti Moll peel.1eA0 , i ;. _ _ N C 5 O E O - o C cTs C▪ 7 -c n CI} V O O 1a7 ID e 0 0 {f} 3I C, 2 1 (o o4 0 cu et ea CC t- L C1 C 1-- z 0 taTi O U C3 c3 0 depth, P1 (in) 1 -hour rainfal to co N- 0 0 Ca ntensity Equation Coefficients = CC a Peak Flow, Q (cfs) Q Ci it, Nei . r C.0 6 I ov-cc r CO ► Ira N Q cCs CD in i. >I t= in O• CN N , • r Ni- l CN es,'caD Oa 4 r {'r} CO r 23.42 O? CSC _ L14.55 4 4 • sr O r CO CS N- t I— >i U) 0.50 4— C O ., (D C� I''- a i 0 CSI i ' ti ' co, 0 . 6 _ in a 6 + N.- co I ro Ce } 6 N1' Rainfall Intensity, I finlhr) L 1 O CD Li • I , , 1 N a i O 05 e CO CD LO L a i , ro O le I <0 OD CO CO . L-, is In CSI cs4 0 - . - (N cNi i N. r r cr5 ivies is i C e 'Li • S., In 3.22 ..111 . CN N Cr; , {i k l i ri - d I icr N.: r CT.; r (N C\) C - r >. 1 4O . r O> r 1 I i r i , _ CO C'4 1 e of Concentration N O NI N. C4 r N Ce) r ... 1 .. 0 .,. , a al a tat,4a's N- di 0 CO "r- 0 to O)) �CN N T� tf) E. C'CD c.) Nt Computed to (min) C.0 Cr) csi co aD ca N cr csi r cc; r r Normal Flow Analysis - Trapezoidal Channel Project: Channel ID: EWS #8 Sec A -A reqd to pass 54.55 cfs T 21 • 1:11° 77 1 Z2 13 Design Information (Input) Channel Invert Slope So = 0.0060 ftlft Manning's n n = 0.040 Bottom Width B = 0.00 ft Left Side Slope Z1 = 4.00 ft/ft Right Side Slope Z2 = 4.00 ftlft Freeboard Height F = 1.00 ft Design Water Depth Y = 2.16 ft Normal Flow Condtion (Calculated) , Discharge Q = 55.55 cfs Froude Number Fr = 0.50 Flow Velocity V = 2.98 fps Flow Area A = 18.66 sg ft Top Width T = 17.28 ft Wetted Perimeter P = 17.81 ft Hydraulic Radius R = 1.05 f Hydraulic Depth D = 1.08 ft Specific Energy Es = 2.30 ft Centroid of Flow Area Yo = 0.71 ft Specific Force Fs = 1.15 kip seta-a.xlsx, Basics 10/26/2018, 1:01 PM 1�I i _ Normal Flow Analysis - Trapezoidal Channel 11 Project: Channel ID: EWS #8 Sec B -B read to pass 22.66 cfs V Z1 B Z2 1 Design Information (Input) Channel Invert Slope So = 0.0060 ftlft Manning's n n = 0.040 Bottom Width B = 0.00 ft Left Side Slope Z1 = 12.50 ft/ft Right Side Slope Z2 = 27.00 ft/ft Freeboard Height F = 1.00 ft Design Water Depth Y = 087 ft Normal Flow Condtion (Calculated) Discharge Q = 24.74 cfs Froude Number Fr = 0.44 Flow Velocity V = 1.65 fps Flow Area A = 14.05 sg ft Top Width T = 34.37 ft Wetted Perimeter P = 34.42 ft Hydraulic Radius R = 0.43 ft Hydraulic Depth D = 0.44 ft Specific Energy Es = 0.91 ft Centroid of Flow Area Yo = 0.29 ft Specific Force Fs = 0.35 kip secB-B.xlsx, Basics 10/2612018, 1:01 PM •s CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: Blue cells are for user data entry Basin ID: Green cells are calculated values Status: die TIT Cate Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull -down list) lean Box Culvert: Barrel Height (Rise) in Feet Barret Width (Span) in Feet Inlet Edge Type (choose from pull -down list) nett flimflam w L Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Enhance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (output): cared Wool.■ sett se D=I 24 inches Square End Projection Height (Rise) _ ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared Wingwall No = Inlet Elev Outlet Elev = L= n= Kb kx 3 3.91 3,78 66 0.016 0 1 0.50 1.23 2.73 0.85 0.1121 ft. elev. ft. elev. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft Culvert Inlet -Control Flowrate cis Outlet Flowrate Culvert -Control cfs Controlling Culvert Flowrate (output) cfs Equation Used: Inlet Flow Control Used 4.80 5.00 9.90 0.00 0.00 Min. Energy. Eqn. N/A 5.00 5.00 14.40 0.00 0.00 Regression Eqn. NIA 5.20 5.00 19.20 20.56 19.20 Regression Eqn. INLET 5.40 5.00 24.30 23.98 23.98 Regression Eqn. OUTLET 5.60 5.00 29.70 24.60 24.60 Regression Eqn. OUTLET 5.80 5.00 35.10 25.70 25.70 Regression Eqn. OUTLET 6.00 5.00 40.50 28.02 28.02 Regression Eqn. OUTLET 6.20 5.00 45.30 30/1 30.71 Regression Eqn. OUTLET MO 5.00 50.10 36.10 36.10 Regression Eqn. OUTLET 6.60 5.00 54.30 41.48 41.48 Regression Eqn. OUTLET 6.80 5.00 58.20 46.25 46.25 Regression Eqn. OUTLET 7.00 5.00 62.10 50.54 50.54 Regression Eqn. OUTLET 7.20 5.00 65.70 54.57 54,57 Regression Eqn. OUTLET 7.40 5.00 69.00 58.25 58.25 Regression Eqn. OUTLET 7.60 5.00 72.30 61/9 61.79 Regression Eqn. OUTLET 7.80 5.00 75.30 65.10 65.10 Regression Eqn. OUTLET OUTLET 78.00 8.00 5.00 68.16 68.16 Regression Eqn. 8.20 5.00 81.00 71.22 71.22 Regression Eqn. OUTLET 8.40 83.70 74.15 74.15 Regression Eqn. OUTLET 8.60 86.10 76.84 76.84 Regression Eqn. OUTLET 8.80 88.80 79.54 79.54 Regression Eqn. OUTLET 9.00 91.20 82.11 82.11 Regression Eqn. OUTLET 9.20 93.60 84.68 84.68 Regression Eqn. OUTLET 9.40 95.70 87.12 87.12 Regression Eqn. OUTLET 9.60 98.10 89.45 89.45 Regression Eqn. OUTLET 9.80 100.20 91.77 94.77 Regression Eqn. OUTLET 10.00 102.60 93,98 93.98 Orifice Eqn. OUTLET 10.20 104.40 96.18 96.18 Orifice Eqn, OUTLET 10.40 106.50 98.38 98.38 Orifice Eqn. OUTLET 10.60 108.30 100.46 100.46 Orifice Eqn. OUTLET Processing Time: Copy of LID -Culvert v3.04.xlsrn, Culvert Rating 01.86 Seconds 10/26/2018, 1:03 PM Determination of Culvert Headwater and Outlet Protection Project: EWS #8 Culvert S2 basin Basin ID: Green cells are calculated values r r C h 9c.a L So V RIPRAP Soil Type: Choose One: O Sandy • Non -Sandy Design Information (Input): Design Discharge Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (Choose from pull -down list) Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (Choose from pull -down list) Number of Barrels Inlet Elevation Outlet Elevation OR Slope Culvert Length Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Tailwater Surface Elevation Max Allowable Channel Velocity Square End Projection Q =I 22.66 Icfs D =1 24 !inches OR Height (Rise) = ft Width (Span) = ft Square Edge w/ 90-15 peg. Headwall No = Eiev IN = Elev OUT = L= n= = kx= Elev Yt -7- V 3 3.91 3.78 65 0.016 0 1 7 ft ft ft ft ft/s Required Protection (Output): Tailwater Surface Height Flow Area al MaxChannel Velocity Culvert Cross Sectional Area Available Entrance Loss Coefficient Friction Loss Coefficient Sum of All Losses Coefficients Culvert Normal Depth Culvert Critical Depth Tailwater Depth for Design Adjusted Diameter OR Adjusted Rise Expansion Factor Flow/Diameteras OR Flow/(Span t Rise' 6) Froude Number TailwateNAdjusted Diameter OR Tailwater/Adjusted Rise Inlet Control Headwater Outlet Control Headwater Design Headwater Elevation Headwater/Diameter OR Headwater/Rise Ratio Minimum Theoretical Riprap Size Nominal Riprap Size UDFCD Riprap Type Length of Protection Width of Protection Yt At - A= = Yn _ Yc = d= Da 1/(2mtan(C)) =- O/O42.5 = Fr = Yt/D = NW1 _ HWo HW = HMO = d50 Type = Lp _ r= 0.80 1.08 3.14 0.50 1.22 2.72 151 0.98 1.49 6.39 1.34 0.43 0.40 ft ft2 ft2 ft ft ft ft €t fe'5is 1.43 Ift 1,60 5.51 Ift 0.80 2 6 VL 6 3 in in ft ft DETENTION VOLUME BY THE MODIFIED FAA METHOD Project: EWS #8 Basin ID: (For catchments less than 160 acres only. For larger catchments, use hydrograph routing method) (NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) Determination of MINOR Detention Volume Using Modified FAA Method Determination of MAJOR Detention Volume Using Modified FAA Method I - -tin n.orrnation n.ut : . e i• n r i orrrtatio MS • Catchment Drainage Impervlowness la = 56.00 percent Catchment Dra.nage Imperviousness la = 56.00 percent Catchment Drainage Area A a 4.850 acres Catchment Drainage Awa A = 4.850 acres Predevelopment NAGS Soil Group Type = C A, B, C, or D Predeveloprnent NRCS Soil Group Type = C A, B., C, or D Return Period for Detention Control T = 10 years (2, 5, 10, 25, 50. or 100 Return Period for Detention Control T -- 100 years (2, 5, 10, 25, SC, or 10D) 'rime of Concentration of Watershed To = 15 minutes Time of Conoentration of Watershed To - 15 minutes Allowable Unit Release Rale q = 0.10 cfs/acre Allowable Unit Release Rats q - 0.36 afsie ore Anne -hour Precipitation P, = 1.47 inches One -hour Precipiiatior P1 = 2.84 inches Design Rainfall IDF Formula I = C,t P,l(C2.T.)AC3 Design Rainfall l0F Formula i = C1'* PI(c2+Tore, Coefficient One C1 = 28.50 Coefficient One C1 = 28.50 Coefficient Two C2 _ 10 Coefficient Two C2 = 10 Coefficient Three Cs a 0.789 Coefficient Three ; = 0.780 D lon of Average Outflow from the Basin lCalculpted}- betermination of Average Out ow from the Basin tealculate Runoff Coefficient C = 0.49 runoff Coefficient C - 0,62 Inflow Peak Runoff Cp-in = 7.86 cfs Inflow Peak Runoff Op -'n r 17.85 cfs µ.11owable Peak Outflow Rate Cp-out = 0.49 cfs Allowable Peak Outflow Rd:e ctp-cut - 176 cfs Mod. FAA Minor Storage Volume = 14,815 cubto feet Mod. FAA Major Storage Volume = 28,697 cubic feat Mod. FAA Minor Storage Vorume = 4.340 acre -ft Mod. FAA Major Storage Volume = 0.559 acre -ft 30 <- Enter Rainfall Duration Incremental Increase Value Here {e.g. 6 ror 6 -Minutes) Rainfall Duration minutes (Input) Rainfall Intensity inches it hr (output) Inflow Volume acre-feet (output) Adjustment Factor -m" (output} Average Outflow cfs (Output) Outflow Volume acre-feet (output) Storage Volume acre-feet (output) Rainfall Duration minutes in.ut Rainfall Intensity inches 1 hr (output} Inflow Volume acre-feet (output) Adjustment Factor °m" (output) Average Outflow as (output) Outflow Volume acre-feet (Output) Storage Volume acre -feel (output) 0 0.00 0.000 0.00 0.00 0.000 0.000 0 0.00 0.000 - 0,00 , 0.00 0.000 0.000 2.28 0.224 0.75 0.36 0.015 0.209 30 4.10 0.509 0.75 1.31 0.054 0.455 60 1.47 0.288 0.63 0,30 0.025 _0.263 60 2.63 0.656 0,63 1.09 0.090 0.564 90 1.11 4.326 0.58 0.28 0.035 0.291 90 1.99 .0 741 0.58 1.02 0.128 0.615 120 0.90 0.354 0.56 0.27 0.045 0.308 120 1.62 0.803 0.56 0.98 0.162 0.641 150 0.76 0.376 0.55 0.27 0.055 0.320 1 150 1.37 0.852 0.56 0.96 0.198 ( 0,654 180 0.67 0.393 0.54 0.26 0.065 0.328. 180 1.20 0:893 0.54 0.659 0.95 0.234 210 0.59 0.400 0.54 0.26 0.075 0.333 210 1.07 0,028 0.54 0.94 0.271 0.658 240 0.54 0.422 0.53 0.28 0.085 0,337 240 0.96 0.959 0.53 0.93 0307 0.653 270 0.49 0.434 0.53 128 0.095 0,339 270 0.88 0,987 0.53 0.92 0.343 0.644 300 0.45 0.445 0.53 0.25 0.105 0.340 300 0.81 1.012 0.53 0.92 0.379 0.633 330 0,42 0.466 0.52 0.25 0.115 0.340 330 0.76 1.035 0.52 0.91 0.415 D.620 360 0.39 0.465 0.552 0.25 0.125 0,339 360 0.71 1.056 0.52 I 0.91 0.451 0.605 390 0 37 0.473 0.562 0.25 0.135 0.338 300 0.67 1.076 0.52 0.01 0.487 0.589 420 0.35 0,482 0.52 0.26 0145 0.336 420 0.63 1.094 0.52 0.90 0,523 0.571 450 0.33. 0,480 0.62 0.26 0155 0.334 4550 0.60 1.112 0.52 0.00 0.559 0.552 480 0.32 0496 0.62 0.26 0.165 0.331 480 0.67 1.126 0.52 0.90 0,561,5 0.533 510 0.30 0.503 0.61 0.25 0.175 0.328 510 0.54 1144 0.51 0.00 0.631 0.512 540 0.29 0.510 0,61 0.25 0.185 0.324 640 _ 0.52 1.155 0.51 0.90 0.667 0.491 570 0.28 0.516 0,81 0.25 0.195 0.321 670 0.60 1.173 0.51 0.90 _ 0.703 0.469 600 0.27 0.522 0.61 0.225 0.205 0.317 600 0.48 1.186 0.51 0,89 0,740 0.447 630 0.26 0 528 0,61 0.25 0.216 0.312 630 0.46 1,199 0.51 0,817 0,776 0.424 660 0.28 0 533 0.61 0.25 0.226 0.308 660 0.44 1.212 0.51 0,89 0,812 0.400 690 0.24 0.539 0.51 0.25 - 0.235 0.303 690 0.43 1.224 0.51 0.89 0.848 0.376 720 0.23 0.544 0.51 0,26 0.246 6.295 720 0.41 1.235 0 51 0.89 0,884 0.362 760 0.22 0.549 0.51 025 - - 0.256 0.203 750 0.40 1.247 0.51 0.09 0.020 0.327 780 0.22 0.553 0.51 0.25 - 0.268 0.288 780 0,39 1.268 0.51 0M9 0.966 0.302 1 810 0.21 0.558 0.51 0.25 - 0.276 0.282 810 0.35 1.268 0.51 0.89 0.992 0.276 840 - 0.20 0.563 0.51 0.26 0.286 0.277 640 0.37 1.278 0.51 0.69 1.020 0250 870 020 0.567 0.51 0.25 0.296 0271 870 0.36 1.2.38 0.51 0.89 1.064 0.224 900 0.19 0.571 0.51 0.25 0.306 0.265 900 0.35 1.208 0.51 0.89 1.100 0.108 930 0.10 0.575 031 0.25 0.316 0.260 930 0.34 1.307 0.51 0.89 1.136 0.171 960 0.18 0.570 0.51 0.25 0.326 0,254 960 0.33 1.316 0.51 0.80 1.172 0.144 990 0.18 0.5683 0.51 025 0.336 0.247 990 0.32 1,325 0.51 0.89 1.20$ 0.117 1020 0,18 0.587 0.51 0.25 0.346 0.241 1020 0.32 1.334 0.51 0.89 1.245 0.089 1050 0 17 0.591 0.51 0.26 0.356 0.235 1050 0.31 1.342 0.61 0.89 1.281 0 062 1050 0' 7 0.694 0.51 0.25 0.365 0-_2220 _ 1080 0,30 1.351 031 0.89 1.317 0 034 1110 0.18 0.608 0.51 0.25 0.376 _ 0.222 1110 0.30 1.359 0.61 0.$8 1.353 0.006 1140 0.16 0.601 0.61 0.25 0,385 0.216 1.140 0.29 1.367 0.61 0.88 1.380 -0.022 1170 0.16 0.05 0.651 0.25 0,396 0,209 1170 0.28 1.374 0.51 0.86 1.425 -0.051 1200 0.1.5 0 80 0.61 0.25 0.406 0.202 1200 0.28 1.302 0,61 0.88 1.461 -0.079 1230 0.15 0 C 1 1 0.51 - 0.25 0.416 0.196 1230 0.27 1.389 0.51 0.88 1.497 -0.108 1260 0.15 0.615 0.61 - 0.25 0.426 0.180 1250 0.27 1.397 0.51 0.88 1.533 -0.136 1290 0.15 0 618 0.61 0.25 0.436 0.182 1200 0.26 1-404 0 51 0,88 1.569 -0.165 1320 0.14 0 621 0.61 0.25 0.446 0.175 1320 0.26 1.411 0 51 0.88 1.005 -0.194 1360 0.14 0 624 0-51 0.25 0.456 0.166 1350 0.25 1.418 0.51 0.88 1.041 -0.224 1380 0.14 0.627 0.51 0.25 0.4€#6 0.161 1360 0.25 1.425 0.51 0.88 1,677 -0.263 1410 0.14 0.630 0.51 0.26 0.476 0.154 1410 0,25 1.431 0.51 0.88 1.714 -0.282 1440 0.13 r 0.255 0.486 0.147 1440 0,24 1.438 0.51 0.88 1/50 -0.312 1470 0.13 r : : r 0.24 0.496 0.140 1470 0,24 1.444 0.51 0.88 1.788 -0.341 1500 - 0.13 r r 0 24 0.506 -- 0.132 1500 0.23 1.461 0.51 0.88 1.822 -0,371 1530 0.13 0.641 0.50 0.24 0.516 I 0.126 1530 023 1.457 030 0.88 1.855 -0.401 1560 0.13 0.644 - 0.50 0.24 0,526 0.118 1580 023 1.4.63 0.60 0-88 1,894 -0.431 1590 0.12 0.640 0.50 0 24 0.536 0.110 1500 0.22 1.460 0.60 0.88 1.930 -0 461 1620 0.12 0.640 0.50 0.24 0.546 0.103 1620 0.22 1.475 0.60 0.88 1.988 -0 491 1650 012 0.662 _ 0.50 0.24 0.556 0.095 1650 0.22 1.481 0.60 0.88 - - 2.002 -0 521 1680 0.12 0.664 0.60 0.24 0.565 O-OB3 1680 0.21 1.486 0.50 0.88 2.03$ -0.552 1710 0.12 0.657 0.60 0.24 0.578 0.000 1710 0.21 1.492 0.50 0.88 2.074 -0.582 1740 0.12 0.550 0.560 0.24 0.686 4073 174O 0.21 1.498 0.50 0.88 2.110 -0.613 1770 0.11 0.662 0.-5C 0.24 0.596 0.065 1770 0.21 1.503 0.50 0.89 2.146 -0.843 18DC: 0.11 0.654 017C 0.24 0 tad 0,050 1300 3 20 1.509 0 50 C.P 2:188 -0.674 od. FAA MinorStorage Volume (cubic ft.) = 14,515 Mod. FAA Ma or Storage Volume (cubic ft.) = Mod. FAA Minor Storage Volume (acre -1L),= 0.3401 Mod. FAA Major Storage Volrxrno (acre -ft,) = UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.: 6, Released January 2015 28,897 0.8588 ews$keoladelention.xls, Modified FAA 10/20t22018, 9:44 AM /8 STAGE -STORAGE SIZING FOR DETENTION BASINS Project; EWS #8 Basin ID; Design Information (Input): Width of Basin Bottom, W = Length of Basin Bottom, L = Dam Side -slope (H:V), Zd = Stage -Storage Relationship: /S&S]c%CZ lc. ft ft ft/ft L Righ Isoscele Circl FirreeLeseede Siid Slope Check Basin Shape t Triangle s Triangle Rectangle e / Eliipse Irregular Storage Requirement from Sheet 'Modified FAA': Storage Requirement from Sheet 'Hydrograph': Storage Requirement from Sheet 'Full -Spectrum'. MINOR OR... OR... OR... OR... (Use Overide values in cells G32:G52) MAJOR 0.34 0.66 acre -ft. acre -ft. acre -ft. Labels for WQCV, Minor, & Major Storage Stages (input) Water Surface Elevation ft (input) 5003.45 5004.00 Side Slope (H:V) ftlft Below El. (input) Basin Width at Stage ft (output) Basin Length at Stage ft (output) Surface Area at Stage ft2 (output) Surface Area at Stage ft2 User Overide Volume Below Stage ft3 (output) Surface Area at Stage acres (output) Volume Below Stage acre -ft (output) Target Volumes for WQCV, Minor, & Major Storage Volumes (for goat seek) 0.00 0.00 0 0.000 I 0.000 25,089 6,899 0.576 I 0.158 5004.57 0.00 0.00 38,409 24,996 0.882 I 0.574 5005.00 0.00 0.00 45,057 42,942 1.034 I 0.986 #NIA #N/A UN/A #NIA #NIA /MIA #NIA UN/A #NIA MIA #NIA MIA #NIA #NIA #NIA #NIA #NIA UN/A #NIA MIA UN/A UN/A #NIA #NIA #NIA 14N/A #NIA UN/A #NIA IIN/A #NIA 11N/A #NIA MIA #NIA #NIA UN/A MIA #NIA #NIA UN/A #NIA UN/A #NIA UN/A #NIA UN/A #NIA UN/A UN/A UN/A #INI/A #N/A #NIA UN/A U VIA. #NIA UN/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA UN/A #NIA #N/A #NIA #NIA UN/A UN/A #N/A #NIA #NIA #NIA #NIA UNIA #NIA ews8keotadetention.xis, Basin 10/26/2018, 12:40 PM Q C C CO • • I 5 E z 0 C C, C 0 U) S r r O I I z 0 a a) 0 z 4E° U 0 a) a co .C 4- 6 O cn 4— O r co co O O co O ;— 'b in ni' QQ O 0 r- I I C.0U Cco .0 a CO E 0 II II 2 o Lto) ` 0 O_ ins 0 O O 0 CO C0 W 4) O 0 a a. O f W I I z U 0 O z I I 0 0 Er CD O0 9) L 0 I I .72 C C) I- .C co W Li- p 1/J I I C r C 0 2 E ■ • C CD E C Watershed Desi CD 0 r CD 0 0 L L_ Q O lEn a) L Q. ■• SI 45 0 nformation C SI 0 co a) 0 p to 7 4 C) c O 0.118 acre-feet 0.142 acre-feet O r I1 II II II c:41 2 r� > L CO ""1". co = co sz: O E 0 81 2 C CD CD ci I- 0 T II II <C CO 03 C• U -CIC° L L c) a3 CO W �3 CO CO Et co 2 4i L CO CO O) O) C C 0 0 co co O F- 10/26/2018, 9:51 AM 0 C U) d O C 0 CO 0 Oa 7,0 co W U O mai I w C) O te O L a z N w a- ce O I C) re I w SE 0 r O O 0} 0) L i X #2 Vertical Orifice i #1 Vertical Orifice LO CO r CS r W .9 I O f L to C, L C. 4 205 w i� a, 0 a 401 a Ca co L CD c13 0 W W Ca L. O w C) SE O C) c sic 75. C) a 0) .rte tisi 13' a) O L c LI L -Cca C) 0 E L � IJ a) u C 6) 43 a)O cr m 'c_ re � ,. O Calculated omit Ca u: -flow area LL I I r H Half Centra a Percent of Design Flow = c 0 C C) 4, O O /�� a 2 C) a 1 I I COM d -w d C 4 Ce) 6 00 crib 00 r r - II II II <o H > v 0 H c 0 to C) 0 SE .L O (1) C E 0 I w a> Co o_ 0 0 CO 0 r w Q 46. a) 0 co O a) SE O C) 2 Q LJ.. LPL i a CO CO 04 o Ci t va LU C) c co 0 cc vzs 0 S a. W 0 O - IIf Cu - 0, co W w O 0 C, W 4 0 t 10/2612018, 9:52 AM a) 03 0 4) C O gias co a) Ct co L99v(\LP JO)=H 499'v(M* PO/O) = H CO I I C f fa n U H 71- 44° 4i 55i` IV 571390 3 ti A 571450 57',510 Hydrologic Soil Group —Weld County, Colorado, Northern Part 571570 Map Scale: 1:2,590 if printed on A landscape (11" x 0.5") sheet 0 35 i0 140 x571630 -t Meters 210 Feet 0 100 200 400 600 Map pwjanori: Web tvlercator ecirnercoordinates: W 84 Edge tics: 11M Zane 13N WC t usnA Natural Resources 7111 Conservation Service 571684 Web Soil Survey National Cooperative Soil Survey 571810 57181D s e a era ,�trr 57187 0 57130 10/24/2016 Page 1 of 4 4C 47 5,5' N 47 42'44h N Hydrologic Soil Group —Weld County, Colorado, Northern Part Area of Interest IAOI) ri MAP LEGEND Area of Interest (AO') Soils Soil Rating Polygons Tk I. 1W A AID B B/D D DID O Not rated or not available Soil Rating Lines A AID paike ,.he B/D telsode C C/D paborh D ,r Not rated or not available Soil Rating Points • A ■ r • ND B B/D ■ • C C!D D a Not rated or not available Water Features Streams and Canals Transportation 41-I Rails ebot Interstate Highways isatzo US Routes Major Roads Local Roads Background Aerial Photography MAP INFORMATION The soil surveys that comprise your ADI were mapped at 1:24, 000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System. Web Mercator (EPSG.3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Weld County, Colorado, Northern Part Survey Area Data: Version 13,. Sep 10, 2018 Soil map units are labeled (as space allows) for map scales 1 54,000 or larger Date(s) aerial images were photographed: Oct 22. 2014 —Oct 2, 2017 The orthophota or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. LINatural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/2412018 Page 2of4 Hydrologic Soil Group —Weld County, Colorado, Northern Part Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of A01 10 36 Avar-Manzanola complex, 0 to 3 percent slopes Manzanola clay loam, 0 C to 3 percent slopes 2.1 6,3% Olney fine sandy loam, B 0 to 6 percent slopes Totals for Area of Interest Description 16.8 14.6 33.5 50.2% 43.5% 100.0% Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long -duration storms. The soils in the United States are assigned to four groups (Al B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink -swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (ND, BID, or /D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. USDA Natural Resources Web Soil Survey Conservation Service National Cooperative Soil Survey 10/24/2018 Page 3 of 4 Hydrologic Soil Group —Weld County, Colorado, Northern Part Rating Options Aggregation Method: Dominant Condition Component Percent Cutoffs None Specified Tie -break Rule: Higher USDA Natural Resources Web Soil Survey arm Conservation Service National Cooperative Soil Survey 10/24/2018 Page 4 of 4 a 0) Z.) Et (IT) Cu J co N Co I 0 0 U. cc C 0 s � a Ct Z Flood Elevation (BFE) ion c .N sal 0 ti) vi 4 "•J Q '- t.I s t1 o C I i I: : i 1 1§ 13 LD 4 Q dl _ 4 at M C E .C t C CC i. XI 1Z VS C O a Q D C5 •+ um C CD a C al 03 o i_ rA bo ri -a 0 ce 4 4- 4/3 0 6 LL dcc In MC Future Conditions 1% Annual Chance Flood Hazard ;Lore,' Area with Reduced Flood Risk due to Levee. See Notes, acne r Area with Flood Risk due to Leveez'rc D kro SCREEN! Area of Min}rnai Flood Hazard t_ Effective LOMRs I Area of Undetermined Flood Hazard Channel, Culvert, or Storm Sewer I 1 Levee, Dike, or Floodwall OTHER AREAS J W cc z Ltl a STRUCTURES Cross Sections with 1% Annual Chance Water Surface Elevation a It of el LL 0 a) C_ J a as XI m 1s g �m I Csbi 1 Limit of Study Jurisdiction Boundary __— --- Coastal Transect Baseline Profile Baseline Hydrographic Feature It VI w W CC aF.- 7 Digital Data Available No Digital Date Available a+ as E fR- d C ` i_ O.a C S C L by ea d} al 3'�c 43 § d al =• v wlet w� g. 1:64; �- d� y C Lco JD V 4. m Lot J � L c. c as, fa 173Q i 'L3 C a7 Ly lJ �f� Edj wa a 1 E 4i 4.8 CI MIS C� X) 7 C e E 2Y E 14 C 121) L p 'CIdi a' C W �+ Ct ha 41 i 2 C Pen ? 4 0 et 14 Qa a' ji. in VI 11 C' rTi C C L LL C sit t L'V ,C �+ pa s. ` Li C N a -I I C 14 8 iI"! y v t i s a i �a 4`� Joy >aE fg cg. I: r� MAP PANELS ass_ '2± c � Ems g. � C 0 9 cs c Q zz 43 b- o ii O+ CL a .C m ( L CL CS ia�- ° 0mu`. Ea g a rTIE -5 L 0 0J 7 r I- rird '104'8'36 30'91V 40a42'43.03'N C 0• 1.0 r 0 0 0 CN C� 0 r O 0 r d tN 668DM L6 8DM 83M REFERENCES 1. URBAN STORM DRAINAGE CRITERIA MANUAL VOLUMES 1,2,3 DATED JUNE 2001 REVISED AUGUST 2008 2. NOAA ATLAS 14 VOLUME 8 VERSION 2 RAINFALL MAPS B. RUNOFF ANALYSIS-UD RATIONAL SPREADSHEET v1.02a DATED SEPT 2005 FROM URBAN DRAINAGE CRITERIA MANUAL VOLUME I 4. CULVERT DESIGN-UD • CULVERT SPREADSHEET v2.00c DATED FEB 2010 FROM URBAN DRAINAGE CRITERIA MANUAL VOLUME 1 S. CHANNEL DESIGN-UD-CHANNELS SPREADSHEET v1.04 DATED OCT 2006 6. UD-BMP SPREADSHEET v3.01 DATED JAN 2011 7. UD-DETENTION 2.2 DATED AUGUST 2011 Zq WERNSMAN ENGINEERING AND LAND DEVELOPMENT lie Eric Wernsnen 16493 Essex Rd Platteville CO 80651 October 22, 2018 Weld County Department of Planning Services 1555 N 17th Ave Greeley, CO 80631 Re: EWS #8 Injection Well Site for Expedition Water Solutions — Traffic Letter To Whom it May Concern: The project site is located in the South East quarter of Section 25, Township 9 North, Range 61 West of the 6th P.M., County of Weld, State of Colorado. The project will consist of an injection well facility for disposal of Oil Field Water. The subject site is adjacent to an existing gas compression station along the west side. The north, east, and south sides of the site are adjacent to undeveloped pasture land. The site will have almost all of the water pumped to this facility and unlike the existing Expedition sites, truck traffic to the site will be minimal. Expedition Water Solutions anticipates that most days there will be less than 5 truck trips to the site. Expedition is stating 20 trucks a day, only in case overflow from another injection well would require trucks to be routed to this site. This is not the planned normal operation, only a back-up plan. There will be approximately 20 passenger vehicle trips to the site per day from the employees. It is anticipated that 50% of the trips will go east and 50% of the trips will go west on CR 100. County Road 100 has 67 average daily trips according to Weld County's latest traffic counts on 3/23/2018. With 40 trips (20 truck trips) a day to the site and assuming 10% of those trips are peak hour trips, this generates 4 trips an hour to the facility. The Weld County vehicle triggers for additional lane construction are as follows: 10 vph during peak hour turning left into the facility — left turn deceleration lane 25 vph during peak hour turning right into the facility — right turn deceleration lane 50 vph during peak hour turning right out of the facility — right turn acceleration it is not anticipated that the site will reach any of these triggers. The overall low levels of traffic associated with this site should not have adverse impacts. Please contact me with any questions. Sincerely, EricWernsman Wernsrnan Engineering and Land Development LW Hello