Loading...
HomeMy WebLinkAbout20190753.tiffORIGINAL PERMIT APPLICANT(S) EVAN MARCELLUS MARK SLOAN TARA MARCELLUS PERMIT TO CHANGE OR INCREASE USE APPROVED WELL LOCATION Water Division: 1 Water District: 2 Designated Basin: N/A Management District: N/A County: WELD Parcel Name: N/A Physical Address: 13507 CR 2.5 BRIGHTON, CO 80603 SW 1/4 NE 1/4 Section 32 Township 1.0 N Range 66.0 W Sixth P.M. UTM COORDINATES (Meters, Zone:13, NAD83) Easting: 517020.0 Northing: 4428671.0 ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit does not ensure that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved pursuant to CRS 37-90-137(4) and the findings of the State Engineer dated May 16, 2018. 4) The use of ground water from this well is limited to two (2) single family dwellings and the irrigation of 28,000 square feet of home gardens and lawn. 5) The pumping rate of this well shall not exceed 15 GPM. 6) The average annual amount of ground water to be withdrawn shall not exceed 1.05 acre-feet. 7) Production is limited to the Laramie -Fox Hills aquifer. 8) The owner shall mark the well in a conspicuous location with well permit number(s), name of the aquifer, and court case number(s) as appropriate. The owner shall take necessary means and precautions to preserve these markings. 9) A totalizing flow meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be maintained by the well owner (recorded at least annually) and submitted to the Division Engineer upon request. 10) This well shall be constructed not more than 200 feet from the location specified on this permit. 11) Pursuant to CRS 37-90-137(9)(b) and the Denver Basin Rules, no more than 98% of the nontributary ground water withdrawn annually shall be consumed and the well owner shall demonstrate to the reasonable satisfaction of the State Engineer that no more than 98% of the water withdrawn will be consumed. 12) This well is subject to administration by the Division Engineer in accordance with applicable decrees, statutes, rules, and regulations. 13) The issuance of this permit hereby cancels permit no. 43889. NOTE: The ability of this well to withdraw its authorized amount of water from this non-renewable aquifer may be less than the 100 years upon which the amount of water in the aquifer is allocated, due to anticipated water level declines. Issued By DEBRA GONZALES Date Issued: 5/17/2018 Expiration Date: 5/17/2019 Printed 05-18-2018 For questions about this permit call 303.866.3581 or go to www.water.state.co.us Page 1 of 1 Application Number: Owner Name: Site Address: WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT 1555 North 17th Avenues Greeley, CO 80631 www.weldhealth.arg Septic Permit Repair SP -1800156 TARA MARCELLUS 13507 CR 2 1/2 BRIGHTON, CO 80603 App Type: Health\Residential\Repair OWTS1Septic Parcel Number: Legal Desc: 13507 CR 2 1/2 BRIGHTON, CO 80603 147132000083-R6299586 16035-B PT N2 32 1 66 BEG AT CEN OF SEC 32 THENCE E ALONG E -W C/L 120' N696' W120' THENCE W122' $696' E122' TO BEG EXC S30' THEREOF Work Description: 2 separate dwellings EHS SEPTIC GENERAL: Number of Bedrooms 6 Number of Persons 5 Parcel Acres 3.87 Private Water Supply Well Private Water Supply Permit Reference 43889 Private Water Supply Permit Reference Number 43889 Public Water Supply No SEPTIC SIZING INFORMATION: From the application information supplied and the on -site soil percolation data the following installation specifications are required: Septic Tank Size (GAL): 1750 Bed Absorption Area for Rock & Pipe(Sqft.) 1620 Application Status: Final Pending Applied Date: 05/04/2018 Intake Person: MHUIZAR Permit Expiration Date: Trench Absorption Area for Rock & Pipe (Sqft.) Bed Absorption Area for Chambers (Sqft.) Trench Absorption Area for Chambers Sqft.) Heel h Adm.nu}ra+lan Vital Records Tele: 970 304-6410 Fax; 970-304-6412 Publk Health & Clinical Services f ele: 970-304-6420 Fax: 970-304-64 3 6 1350 1134 945 Env*onmenloi liealihe Services Tele: 970-304-64[5 Fax; 970.304.6411 Communication, Education, & Planning Tele: 97D-304-6470 Fax: 970-304-6452 minimum Emergency Preparedness & Re$ponte Tele: 97i1.30d-6470 Fax: 970-304-6452 Page 1 of 3 PubH&Health WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT 1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth.org Septic Permit Repair EHS PERC TEST (SITE) : % Ground Slope Engineer Design Required In 100 Year Flood Plain Limiting Zone Feet Limiting Zone Qualifier Long Term Acceptance Rate Percolation Rate Qualifier Percolation Rate Value Profile Pits Slope Direction Soil Description Soil Type Soil Type Suitable Treatment Level 3 No No 8 Greater Than 0.5 Equal To 35 2 West Sandy Loam 2A Yes Level 1 Number of Chambers Required for a Bed Number of Chambers Required for a Trench Maximum Number of Chambers Per Row Chamber Options: 1) Standard Biodiffuser & Infiltrator H-10 63 53 16 2) Biodiffuser ARC36 Std. or High Capacity 76 63 20 3) ADS ARC36 Std. 76 63 20 4) ADS36 High Capacity 76 63 20 5) ADS ARC36 Low Profile 76 63 20 6) Quick4 Plus Standard or High Capacity 95 79 25 7) Quick4 Plus Standard 95 79 25 8) Quick4 EQ36 142 119 25 9) Quick4 Plus Low Profile 95 79 25 Hwl1h Adminlshailon 1111& Records fele: 9?0-304-6410 Fax; 970-04-6412 Public Health L Glinted Services rele: 970.3046120 °ax; 970-.104-6416 Environmâ–ºnlol Health Services Te1e' 970-304-6415 Fa*1 970-301-.64[1 CornrnvniCarlion, Education L Planning Tele: 970-304-6470 Fax: 970.304.6452 Emergency Preparedness } Il+rkont. rete: 970-304-6470 Fat: 970-304-6452 Page 2 of 3 Pubfl,&Heelth WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT cc 1555 North 17th Avenue, Greeley, CO 80631 www,weldhealth.org Septic Permit Repair CONDITIONS: Onsite wastewater treatment system must be 10 feet from property line. Install the soil treatment area within 50 feet of the soils test location. Septic tank must be at least 50 feet from any well. Soil treatment area must be at least 100 feet from any well. Soil treatment area must be 10 feet from lined irrigation ditch. Sewer line to septic tank must have at least 1/flinch/ft. fall. Effluent line from septic tank to distribution box must have at least 1/8inch/ft. fall. Install inspection ports at the ends of each trench or bed. All Weld County regulations are applicable. INSPECTION RESULT: Description: Comment: Status: NOTICE This permit is granted temporarily to allow construction to commence. This permit may be revoked or suspended by the Weld County Department of Public Health and Environment for reasons set forth in the Weld County Individual Sewage Disposal System Regulations including failure to meet any term or condition imposed thereon during temporary or final approval. The issuance of this permit does not constitute assumption by the department or its employees of liability for the failure or inadequacy of the sewage disposal system. This permit is non -transferable and non-refundable. Before issuing final approval of this permit the Weld County Department of Public Health and Environment reserves the right to impose additional terms and conditions required to meet our regulations on a continuing basis. Final permit approval is contingent upon the final inspection of the completed system by the Weld County Department of Public Health and Environment. Alex Clemments May 10, 2018 Environmental Health Specialist Date Health Adminlsha%Ion vlial Recalls Take: 970-304.6410 Fax.: F70-3aa4-6412 Public Health & CYnkd Services Tele: 970-304-6424 Fax: 970-304-64',6 Envianmenlai" Health Services Tele: 470.304-64 t 5 Fax: 970-304.6.0 Conamgincot;6n, Edvcnlian . ?I -tinning Emergency Preparedness Response Tele: 970-304-6410 Far 970-36`4-6452 Page 3 of 3 Publicit/oath Hello