HomeMy WebLinkAbout20190132.tiffForm No. OFFICE OF THE STATE ENGINEER
GWS-25 . , COLORADO DIVISION OF WATER RESOURCES
016 Centennial Bldg., 1313 Sherman St, Denver, Colorado 30203
(363) 866-3581
857
APPLICANT
KENT & NANCY JORDON
304 BEACON HILL DR
LAFAYETTE CO 80026-
(303)665-7553
PERMIT TO CONSTRUCT A WELL
WELL PERMIT NUMBER 2 766
DIV. 1 CNTY. 62 WD 2 DES. BASIN MD
Lot: Block: Filing: Subdly:
APPROVED WELL L0OATfON
WELD COUNTY
NW 1/4 NW 1/4 Section 19
Twp 2 N RANGE 86 W 6th P.M.
DISTANCES_FROM SEC71ON LINES
970 Ft. from - North Section Line
150 Ft. from West Section Line
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDTl7ONS OF APPROVAL
1) This well shall be used in such a way as to cause no material Injury to existing water rights. The Issuance of the
permit does not assure the applicant that no injury will occur to another vested water right or preclude another
owner of a vested water right from seeking relief in a civil court action,
2) The construction of this weN shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless
approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump
Installation Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-92-802(3)(b)(II)(A) as the only well on a tract of land of 38.7 acres described as part
of the NW1/4 Section 19, Township 2 North, Range 66 West, Sixth Principal Meridian, More particularly described
on the attached exhibit A.
4) The use of ground water from this well Is limited to ordinary household purposes inside not more than three single
family dwellings, fire protection, the watering of poultry, domestic animals, and livestock on farms and ranches,
and the irrigation of not over one acre of home gardens and lawns.
5) Production from this well is restricted to the Laramie Fox -Hills aquifer which corresponds to the interval between
280 feet and 555 feet below ground surface. Plain casing shall be installed and grouted to prevent production
from other zones.
The maximum pumping rate shall not exceed 15 GPM.
R
The return flow from the use of the well must be through an individual waste water disposal system of the
non -evaporative type where the water is returned to the same stream system in which the well is located.
8) This well shall be constructed not more than 200 feet from the location specified on this permit.
Note: To Insure a maximum productive life of this well, perforated casing should be set through the entire
producing interval of the approved zone or aquifer indicated above.
Note: The ability of this weir to withdraw its authorized amount of water from this non-renewable aquifer
may be less than the 100 years upon which the amount of water in the aquifer is allocated, due
to anticipated water level declines.
6)
7)
APPROVED
RANMats Engineer
Receipt No. 0422873
/id z .
DEC 0 31997
BY
DATE ISSUED EXPIRATION DATE DEC
3 1' 9
I
Scanning Cover Sheet
for
Septic Permits
Permit #
Permit Type:
SP -9700531
Health / Residential / New
Situs Street Address 8804 CR 26
Situs City, State, Zip
Sec/Town/Range: 19 -02N -66W Application Status: Finaled
Application Date: 12/04/1997
Parcel # (12 digits)
130919203002-R7462698
Owner Full Name: JORDAN KENT & NANCY
Owner Address: 304 BEACON HILL DR
LAFAYETTE,CO 80026
Contact Name: JORDAN NANCY
Contact Address: 304 BEACON HILL
LAFAYETTE,CO,80026
Owner Phone #: 303-665-7553 •
Contact Phone# 303-665-7553
Information above has been Verified in Ac ela by employee noted below
Report ID: EHS00024v003
Print Date -Time: 7/1/2008 10:15:41 AM
July 01, 2008
Date
Page 1 of 1
Hello