Loading...
HomeMy WebLinkAbout20212878.tiffArchitecture Structural Geotechnical ROCKY MOUNTAIN GROUP Materials Testing Forensic Civil/Planning EMPLOYEE OWNED SUBSURFACE SOIL INVESTIGATION 2198 CR 17 Brighton PREPARED FOR: Innotech Machining, Inc. 6125 West 59th Avenue, Suite E Arvada, CO 80003 JOB NO. 173889 October 10, 2020 Respectfully Submitted, RMG — Rocky Mountain Group Dale W. Guillen, P.E. Senior Engineer Southern Office: Colorado Springs, CO 80918 719.548.0600 Central Office: Englewood, CO 80112 3 03.68 8.9475 Northern Office: Evans, CO 80620 970.330.1071 www.rmgengineers.com Fort Collins: 970.616.4364 Monument: 719.488.2145 Woodland Park: 719.687.6077 2198 17 Brighton Scope of Investigation RIVIG — Rocky Mountain Group drilled three test borings at the above -referenced address on September 10t. A Site Vicinity Map and Test Boring Location Plan are presented in Figures 1 and 2, respectively. p our findings, conclusions and recommendations are provided in this report. We understand that the existing single family residence resides on the current property and that a new structure is being built. The location of this new structure being built is located behind the existing garage/shop and it will be attached to the existing garage/shop. This report presents geotechnical engineering recommendations for design and construction of residential foundations. The following is excluded from the scope of this report including but not limited to geologic, natural and environmental hazards such as landslides, unstable slopes, seismicity, snow avalanches, water flooding, corrosive soils, erosion, radon, wild fire protection, hazardous waste and natural resources. Subsurface Materials The subsurface materials encountered in the test borings generally consisted of medium stiff to very stiff sandy clay that extends to a depth of 12ft and sits on top of firm to medium hard claystone/bedrock that extends to the 20 -foot termination depths of the test borings. Additional descriptions and the interpreted distribution (approximate depths) of the subsurface materials are presented in the Test Boring Logs. Groundwater was not encountered in the test borings at the time of drilling. When checked one day subsequent to drilling, groundwater was encountered in all 3 bores at depths ranging between 17.5 and 18.5 feet below existing grade. Fluctuations in groundwater and subsurface moisture conditions may occur due to variations in rainfall and other factors not readily apparent at this time. Development of the property and ad] acent properties may also affect groundwater levels. The Test Boring Logs, an Explanation of the Test Boring Logs and a Summary of Laboratory Test Results are presented in Figures 3 through 5. Soil Classification Data and Atterberg Limits are presented in Figure 6. Swell/Consolidation Test Results are presented in Figures 7 and 8. Geotechnical Considerations Soft/loose and dry soils were not encountered at anticipated foundation bearing levels. If soft/loose or dry soils are encountered in the excavation, they will require additional compaction to achieve the allowable bearing pressures indicated in this report. We recommend reconditioning the soils beneath the foundation components prior to constructing the foundation by scarifying the top 12", moisture conditioning and compacting the soils. Please reference the Structural Fill section below for compaction recommendations. The use of track -mounted excavation equipment or other low -ground -pressure equipment is recommended to reduce the likelihood of loss of stability duringexcavation. Foundation Recommendations A spread footing foundation supported on the properly reconditioned on -site sand soils is suitable for the proposed structure. A maximum allowable bearing pressure of 2000 psf with a no minimum dead load requirement may be used for design. The foundation design should be prepared by a qualified Colorado Registered Professional Engineer using the recommendations presented in this report. This foundation RMG — Rocky Mountain Group 2 RMG Job No. 173889 155 Palmer Dr LOT 6, Fairway Estates Fort Collins, Colorado system should be designed to span a minimum of 10 feet under the design loads. The bottoms of exterior foundations should be at least 30 inches below finished grade for frost protection. Open Excavation Observation During construction, foundation excavations should be observed by RMG prior to placing structural fill, forms, or concrete to verify the foundation bearing conditions for each structure. Based on the conditions observed in the foundation excavation, the recommendations made at the time of construction may vary from those contained herein. In the case of differences, the Open Excavation Observation report shall be considered to be the governing document. The recommendations presented herein are intended only as preliminary guidelines to be used for interpreting the subsurface soil conditions exposed in the excavation and determining the final recommendations for foundation construction. Soil Test Borings The soil/rock classifications shown on the logs are based upon the engineer's classification of samples. Lines shown on the logs represent the approximate boundary between subsurface materials, and the actual transition may be gradual and vary across the site. Interior Partitions Interior non-bearing partitions and attached furnishings (e.g., cabinets, shower stalls, etc.) on concrete slabs should be constructed with a void so that they do not transmit floor slab movement to the roof or overlying floor. A void of at least 1-1/2 inches is recommended beneath non-bearing partitions. Doors should be provided with at least a 1 inch gap at floor level. Voids and gaps may require reconstruction over the life of the structure to re-establish the void due to vertical slab movement. Surface Grading and Drainage The ground surface should be sloped from the building with a minimum gradient of 10 percent for the first 10 feet. This is equivalent to 12 inches of fail across this 10 -foot zone. If a 10 -foot zone is not possible on the upslope side of the structure, then a well-defined swale should be created a minimum 5 feet from the foundation and sloped parallel with the wall with a minimum slope of 2 percent to intercept the surface water and transport it around and away from the structure. Roof drains should extend across backfill zones and landscaped areas to a region that is graded to direct flow away from the structure. Homeowners should maintain the surface grading and drainage recommended in this report to help prevent water from being directed toward and/or ponding near the foundations. Landscaping should be selected to reduce irrigation requirements. Plants used close to foundation walls should be limited to those with low moisture requirements; and irrigated grass should not be located within 5 feet of the foundation. To help control weed growth, geotextiles should be used below landscaped areas adjacent to foundations. Impervious plastic membranes are not recommended. Irrigation devices should not be placed within 5 feet of the foundation. Irrigation should be limited to the amount sufficient to maintain vegetation. Application of more water will increase the likelihood of slab and foundation movements. RMG — Rocky Mountain Group 2 RMG Job No. 175006 155 Palmer Dr LOT 6, Fairway Estates Fort Collins, Colorado The recommendations listed in this report are intended to address normal surface drainage conditions, assuming the presence of groundcover (established vegetation, paved surfaces, and/or structures) throughout the regions upslope from this structure. However, groundcover may not be present due to a variety of factors (ongoing construction/development, wildfires, etc.). During periods when groundcover is not present in the "upslopen regions, higher than normal surface drainage conditions may occur, resulting in perched water tables, excess runoff, flash floods, etc. In these cases, the surface drainage recommendations presented herein(even if properly maintained) may not mitigate all groundwater problems or moisture intrusion into the structure. We recommend that the site plan be prepared with consideration of increased runoff during periods when groundcover is not present on the upsiope areas. Perimeter Drain A subsurface perimeter drain is recommended around portions of the structure which will have habitable or storage space located below the finished ground surface. This includes crawispace areas but not the walkout trench, if applicable. The perimeter drain can be installed as an interior (if a minimum of six inches of free draining aggregate is placed beneath the slab) or exterior perimeter drain system. The perforated drainage pipe should be installed so the top of the pipe is not above the top of the footing and should be surrounded by material to reduce the infiltration of silt into the drainage pipe. The pipe should be installed in one of the following manners: 1) The pipe may be installed as level as possible as long as the pipe is placed in a minimum of six inches of gravel or crushed stone and exits into a sump pit with mechanical means to remove the water. Or 2) The pipe may be installed as a gravity system with a minimum 1/8 inch fall per 1 foot length surrounded by a minimum six inches of gravel or crushed stone that either daylights to allow free flow drainage or exits into a sump pit with mechanical means to remove the water. A subsurface perimeter drain is designed to intercept some types of subsurface moisture and not others. Therefore, the drain could operate properly and not mitigate all moisture problems relating to foundation performance or moisture intrusion into the basement area. Concrete Sulfate testing was performed on selected samples based on ASTM C1580. Test results showed 0.47% by weight, indicating the soils present Class 2 med to high) sulfate exposure. Based on these results Type V cement or equivalent mixture according to AC1 201.2R-10 is suggested for concrete in contact with the subsurface materials. Cement type shall be designed and approved by a licensed Colorado Professional Engineer and Foundation Designer. Calcium chloride should not be used for the onsite soils. The concrete should not be placed on frozen ground. If placed during periods of cold temperatures, the concrete should be kept from freezing. This may require covering the concrete with insulated blankets and heating. Concrete work should be completed in accordance with the latest applicable guidelines and standards published by ACI. RMG — Rocky Mountain Group 3 RMG Job No. 175006 155 Palmer Dr LOT 6, Fairway Estates Fort Collins, Colorado Exterior Backfill Backfill should be placed in loose lifts not exceeding 8 to 12 inches, moisture conditioned to facilitate compaction (usually within 2 percent of the optimum moisture content) and compacted to 90 percent of the maximum dry density as determined by the Standard Proctor test, ASTM D-698 on exterior sides of walls in landscaped areas. In areas where backfill supports pavement and concrete flatwork, the materials should be compacted to 95 percent of the maximum dry density. Fill placed on slopes should be benched into the slope. Maximum bench heights should not exceed 4 feet, and bench widths should be wide enough to accommodate compaction equipment. The appropriate government/utility specifications should be used for fill placed in utility trenches. If material is imported for backfill, the material should be approved by the Geotechnical Engineer prior to hauling it to the site. The backfill should not be placed on frozen subgrade or allowed to freeze during moisture conditioning and placement. Backfill should be compacted by mechanical means, and foundation walls should be braced during backfilling and compaction. Structural Fill Areas to receive structural fill should have topsoil, organic material, or debris removed. The upper 6 inches of the exposed surface soils should be scarified and moisture conditioned to facilitate compaction (usually within 2 percent of the optimum moisture content) and compacted to a minimum of 95 percent of the maximum dry density as determined by the Standard Proctor test (ASTM D-698). Structural fill placed on slopes should be benched into the slope. Maximum bench heights should not exceed 4 feet, and bench widths should be wide enough to accommodate compaction equipment. Structural fill shall consist of granular, non -expansive material, and it should be placed in loose lifts not exceeding 8 to 12 inches, moisture conditioned to facilitate compaction (usually within 2 percent of the optimum moisture content) and compacted to a minimum of 95 percent of the maximum dry density as determined by the Standard Proctor test, ASTM D-698. The materials should be compacted by mechanical means. Materials used for structural fill should be approved by RMG prior to use. Structural fill should not be placed on frozen subgrade or allowed to freeze during moisture conditioning and placement. To verify the condition of the compacted soils, density tests should be performed during placement. The first density tests should be conducted when 24 inches of fill have been placed. Foundation Configuration Remarks The configuration of the foundation system is critical to its performance. The position of foundation windows, jogs, steps and the relative elevation of adjacent and opposite walls can affect foundation performance. The nature of residential foundation construction does not allow for control of these conditions by the Foundation Design Engineer. Improper placement of the above can result in RMG — Rocky Mountain Group 4 RMG Job No. 175006 155 Palmer Dr LOT 6, Fairway Estates Fort Collins, Colorado differential and lateral foundation movement not anticipated by the Geotechnical Engineer. The Foundation Design Engineer should be contacted regarding the foundation configuration. General Remarks The recommendations provided in this report are based upon the subsurface conditions encountered in the test borings, anticipated foundation loads, and accepted engineering procedures. The recommendations are intended to reduce differential movement. It must be recognized that the foundation will undergo some movement on all soil types. Concrete floor slabs will likely move vertically. The recommendations for isolating floor slabs from columns, walls, partitions or other structural components should be implemented to mitigate potential damage to the structure. Subsequent owners should be provided a copy of this report. The recommendations are based on accepted local engineering practice and are intended for individuals familiar with local construction practices and standards. RMG does not assure the existence of and/or the compliance with the above recommendations. This is the responsibility of the client referenced on the first page. RMG provided recommendations only and does not supervise, direct or control the implementation of the recommendations. RMG — Rocky Mountain Group 5 RMG Job No. 175006 t th St Duluth Trading Company Temporarily closed m It Po 4000 PPM a PAM DPgitate3 £t Pk Allna3 PIB B l Pd Altnoo PIaM 0 SITE F 168th Ave F 1 G8th Ave F El liEl E 168tH Are L^I 1; D 19 ID 19 L i Gbth Awe VICINITY MAP 2198 WELD COUNTY ROAD 17 BRIGHTON, COLORADO CLIENT INNOTECH MACHINING, INC. 6125 W. 59TH AVENUE, SUITE E ARVADA, CO. 80003 RMG PROJECT 4173889 DATE: 4 17 20 ROCKY MOUNTAIN GROUP 1601 37th STREET EVANS, CO. 80620 PHONE: (970) 330-1071 FAX: (970) 330-1252 0 50 100 SCALE: 1" = 100' BORE LOCATION PLAN 2198 WELD COUNTY ROAD 17 BRIGHTON, COLORADO CLIENT . I NNCTECH MACHINING, INC. 6125 W. 59TH AVENUE, SUITE E ARVADA, CO. 80003 RMG PROJECT #173889 DATE: 10/12/20 ROCKY MOUNTAIN GROUP 1601 37th STREET EVANS, 00. 80620 PHONE: (970) 330-1071 FAX: (970) 330-1252 TEST BORING: 81 DATE DRILLED: 9110/20 REMARKS: @ dry' 9/11/20 _,w 00 2 u) oJ- Q w WATER CONTENT % TEST BORING: B2 DATE DRILLED: 9!10!20 REMARKS: GROUNDWATER (a� dry' 9/11/20 _I °° � co c0 a Q coGROUNDWATER WATER CONTENT °/y/ BLOWS PER BLOWS PER I EF'TI PTI CLAY, brown medium silty to grey, orange, stiff to very stiff, and dry white, 5 V % A 16 10 41 45 - 16.1 157 17.7 16.9 CLAY, brown dry silty with white streaks, stiff, 5 / �A A 9 24 43 50/10" 10.1 19.1 18.' 18 10 10 CLAYSTONE brown, medium orange hard, dry and grey, firm to 15 CLAYSTONE brown, orange and grey, firm, dry 15 � 20 20 A L � Architectural Structural Fcrcnsics ROCKY MOUNTAIN GROUP Colorado Springs- (Corporate Office) 2910 Austin Bluffs Parkway Colorado Spings. CO80918 (719) E48-0600 SOUTHERN COLORADO. DENVER METRO, NORTHERN COLORADO Gcotcchnical Matcrials Testing Civil Planning TEST BORING LOGS JOB No. 173889 FIGURE No. 3 DATE Oct/06/2020 6 I SOILS DESCRIPTION SYM 11 XX CLAYSTN E SILTY CLAY UNLESS NOTED OTHERWISE, ALL LABORATORY TESTS PRESENTED HEREIN WERE PERFORMED BY: RMG - ROCKY MOUNTAIN GROUP 1601 37TH ST. EVANS, COLORADO OLS AND NOTES STANDARD PENETRATION TEST - MADE BY DRIVING A SPLIT -BARREL SAMPLER INTO THE SOIL BY DROPPING A 140 LB. HAMMER 30", IN GENERAL ACCORDANCE WITH ASTM D-1586. NUMBER INDICATES NUMBER OF HAMMER BLOWS PER FOOT (UNLESS OTHERWISE INDICATED). UNDISTURBED CALIFORNIA SAMPLE - MADE BY DRIVING A RING -LINED SAMPLER INTO THE SOIL BY DROPPING A 140 LB. !HAMMER 30", IN GENERAL ACCORDANCE WITH ASTM D-3550. NUMBER INDICATES NUMBER OF HAMMER BLOWS PER FOOT (UNLESS OTHERWISE INDICATED). FREE WATER TABLE DEPTH AT WHICH BORING CAVED BULK DISTURBED BULK SAMPLE .AUG AUGER "CUTTINGS" TTINGS" 4 WATER CONTENT (%) Architocturd Structural Forensics ROCKY MOMOUNTAIN 0 ROU P Colorado SprJngs• (Corporate °ff it 2910 Austin Bluffs Parkway Cdcracb Spings, CO 8O918 (719) 548-0600 SOUTHERN COLORADO, DENIER METRO, NORTHERN COLORADO GcotechnicI Materials Tcsting Civil, Planning v J‘k, _ EXPLANATION OF TEST BORING LOGS v JOB No. 173889 FIGURE No. 4 DATE Oct/06/2020 2 f Test Boring No. Depth P Water Content 4 (/gym Dense (pcf Liquid Limit Plasticity Index No.4 Retained Sieve Passing Passing 200 Sieve No. % Collapse Swell/ Load (psf) B1 4.0 16.1 106.8 B1 9.0 15.7 112.7 45 33 0.2 96.1 0.8 1000 B1 14.0 17.7 111.3 2.3 1000 B1 19.0 16.9 112.8 B2 4.0 10.6 105.0 40 25 76.6 - 0.3 1000 B2 9.0 19.6 103.6 B2 14.0 18.1 110.2 B2 19.0 18A 110.0 t i Arehitoetural Structural Forensics ROCKY MOUNTAIN GROUP Colorado Sprkigs• (Corporate Offb j 2910 Austin Bluffs Parkway Cdcratlo Spings, CC 80918 (719) 518-0600 SOUTHERN COLORADO, DENIER METRO, NORTHERN COLORADO Gcotochnieal Materials Testing Civil, Planning v SUMMARY OF LABORATORY TEST RESULTS V JOB No. 173889 FIGURE No. 5 PAGE 1 OF 1 DATE Oct/06/2020 J 100 90 H80 2 7 ED60 O z X50 a -40 z W L30 W a 20 10 0 U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS 3 1.5 1 3/4 1/23/8 4 10 20 40 100 200 HYDROMETER 100 10 1 GRAIN SIZE IN MILLIMETERS 0.1 0.01 0.001 COBBLES ORAI�EL SAND SILT OR CLAY coarse fine coarse medium fine Test Boring Depth (ft) Classification LL PL PI B1 9.0 LEAN CLAY( L) 45 12 33 I B2 4.0 LEAN CLAY with SAND(CL) 40 15 25 Test Boring Depth (ft) %Gravel ravel %Sand %Silt %Clay B1 9.0 0.2 3.7 96.1 I B2 4.0 0.0 23.4 76.6 Architcctural Structural Fcrcnsics ROCKY MOUNTAIN GROUP ARCHITECTS RMG EN (3IN,ILEHS Cdcricic Springs (Ccrperote Office) 2910 Austin Bluffs Parkway Cdcrada Spings, CO 80918 (719) E48-0600 SOUTHERN COLORADO, DENVER METRO, NORTHERN COLORADO GcbtcchnicI Matcrials Tcsting Civil, Planning -b\fr SOIL CLASSIFICATION DATA JOB No. 173889 FIGURE No. 6 DATE Oct/06/2020 2 z 0 z C O X W z 0 C1) Co W O C z 0 z C 0 >C w z 0 COMPRESS COMPRESS - 1.0 - 2.0 - 3.0 -4.0 -5.0 - 6.0 100 - 1.0 - 2.0 - 3.0 -4.0 -5.0 - 6.0 100 S APPLIE 1 F.EI RE - PSF PROJECT: 2198 CR 17 brighton SAMPLE DESCRIPTION: Clay NOTE: SAMPLE WAS INUNDATED WITH WATER AT 1000 PSF SAMPLE LOCATION: B1 @ 9 FT NATURAL DRY UNIT WEIGHT: 114.0 PCF NATURAL MOISTURE CONTENT: 15.2% PERCENT SWELL/COMPRESSION: 0.8 10,000 APPLIED P1RE S RE - PSF PROJECT: 2198 CR 17 brighton SAMPLE DESCRIPTION: Claystone NOTE: SAMPLE WAS INUNDATED WITH WATER AT 1000 PSF Architectural Structural Fcrcnsics ROCKY MOUNTAIN GROUP Colorado Springs- (Corporate Office) 2910 Austin Bluffs Parkway Colorado Spings. CO80918 (719) E18-0600 SOUTHERN COLORADO. DENVER METRO, NORTHERN COLORADO Gcotcchnical Matcrials Testing Civil Planning SAMPLE LOCATION: B1 @ 14 FT NATURAL DRY UNIT WEIGHT: 91.1 PCF NATURAL MOISTURE CONTENT: 16.4% PERCENT SWELL/COMPRESSION: 2.3 SELL/CONSOLIDATION TEST RESULTS eals, _ V 10,000 JOB No. 173889 FIGURE No. 7 DATE Oct/06/2020 1%%N\ - 1.0 fig z O z C O W z O COMPRESS - 2.0 - 3.0 -4.0 -5.0 - 6.0 100 APPLIE DPIPTFli.LICSTU RE - PSF PROJECT: 2198 CR 17 brighton SAMPLE DESCRIPTION: Silty Clay NOTE: SAMPLE WAS INUNDATED WITH WATER AT 1000 PSF Architectural Structural Fcrcnsics ROCKY MOMOUNTAIN G ROU P Colorado Springs- (Corporate Office) 2910 Austin Bluffs Parkway Colorado Spings. CO80918 (719) E18-0600 SOUTHERN COLORADO. DENVER METRO, NORTHERN COLORADO Gcotcchnical Matcrials Testing Civil Planning SAMPLE LOCATION: B2 @ 4 FT NATURAL DRY UNIT WEIGHT: 98.9 PCF NATURAL MOISTURE CONTENT: 10.1% PERCENT SWELL/COMPRESSION: - 0.3 V SELL/CONSOLIDATION TEST RESULTS eals, _ 10,000 JOB No. 173889 FIGURE No. 8 DATE Oct/06/2020 Hello