HomeMy WebLinkAbout720438.tiff COLORADO DEPARTMENT IF HEALTH EATER POLLUTION CONTROL COMMISSION ik210 fast 11 Avenue Denver, Colorado 80220 -- APPLICATION FOR APPROVAL OF LOCATION! -- FOR SEWAGE TREATMENT FACILITIES Submit in duplicate Complete only Parts A & B See lnstruci:ioa:: Applicant: Town of Severance, % Dolores Ihfe, Town Clerk _ Address : Severance( Weld County, Colorado 8o546 • A. INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW: 1 . Size and type of treatment facility: 50,000 gpd Extended Aeration 2. Location of Facility: Southeast Corner of the NE I, Sect. 2, T. 6tf, _-- 3. Ne.ne of watercourse into which effluent is discharged:Tributnry to c'=_e'u.;i k. Location of effluent discharge: into the Law Reservoir located all '6_Ic;_:_• . portion of said Section 2. 5, Describe and give distance downstream of water plant raw water intac ne:t; �i effluent discharge: No known raw water intake in Colorado. 6. Est.project cost:$76,500.00 Est.bid opening date:l2/15/2st.compl .date: :'�+,1'; ' 7. Project layout and design criteria: (Attach separate sheets or report entire service area with respect to surrounding areas, habitable buildings , loc..- Lion of potable water wells with 4 mile, effluent discharge point and to,.o_.jr,p:;y of area, population to be served. ) 8. Additional information may be required, upon request of the District Ene i neer 6o6 local health department officials. This may include (a) relationship of th..; facility to area-wide plan , (b) flood plain data, (c) provision for mair,l:eoes-ce. and operation of the facility including odor control (d) legal status (districs_, association , municipality) . 9. Have you contacted local planning and building officials or other county otficla5 regarding building permits, zoning matters, special use review per and oci,c;r similar matters: Yes (Name of those contacted) 10. Consulting Engineer: J.J. BROGG;�ER AND ILLSCCIATES Address: P.O, Box 428,_ Limon, Colori,.c:o 80828 Telephone =5:f'`=';'_ The undersigned applicant agrees to supply information necessary for Review or +' i.-ns eed Specifications and to secure signatures of the appropriate local government officials prio. to submission. (See part B on back of this sheet.) J Date Signature of Applicant 1.4r. i aroa,ci ii. ;1. a, i i L it aahL Es. S i G%:,'�"t" ORE OF LOCAL GOVERNMENT OFFICIALS: The l unders i gned* have; rev:<:+.an2 proposal for the location, construction, operation, and point of of flutJn tii: {:t",,.:','j•: or the above-described sewage treatment facility, and RECOMMEND APPROVAL or i iS-. APPROVAL in space provided below: RECOMMEND RECOMEND DATE APPROVAL DISAPPROVAL r•, 172.-- fh - Signature, for L cal YHeal h D;;;par+_k::::,:: Signature for Planning. Commission • Signature for Board of Cucs,z«.y �Go:,raCss S i Cjncatace for Mayor of City MLihar:, r G►' - Municipa it`f *before plans and specifications will be accepted for review, the appi icant: must hereon the action taken on the project by the Local I`ealth Officers , repre5entt..i_ive C'+ the Planning Commission, representative of the Board of County Commissioners , ;..no the Mayor or City Manager of the municipality that might- be affected by the disc:'arg:.. of this waste;. C. THE FOLLOWING FOR STATE HEALTH DEPARTMENT USE: • I , the undersigned District Engineer, have the: following comments : 1 . is this plant located so that it can serve the needs of the present :;end/e..' future logical service 2. ;s the plant located where it is likely to create: nuisance problems ft.) existing or now planned development? 3. Has a sufficient amount of suicabie land ucen set aside•for expansion? 4. Has the developer or owner or the facility mado provision Ior aJoguiii...' to buy, maintain, operate, and repair or replace in kind the facility/ 5. Are: there any community water supply intakes within 5 miles uownstre,:lia oaf tit effluent discharge points? ____..__._.. �.._.___...... D. RECOMMENDATIONS: Date. Signature , 7ti-2tl) BEFORE THE WELD COUNTY, COLOrA D') PLANNING COMMISSION RESOLUTION OF RECOMMENDATION TO THE BOARD OF COUNTY COMMISSIONERS Case No. Date 11 /22/72 APPLICATION OF, Town of Severance ,.._.C./.O. ..D.A.1.0.r..e.S I.h.fs.., TOw.I' Clerk Address. Seve,rance..,.....C.O.i_O.ra.d.o 8.0.5.4.6 Moved by John Watson that the following resolution be introduced for passage by the Weld County Planning Commissicnr Be it Resolved by the Weld County Planning Commission that the application for sceRTADEc4FLNI • ( - Dlefat&a • -•.....• ( xcx@kttrecirCkg . _APP.ROYALCS LOCATION - 0f SEWAGE T•R.E.ATM.E.NT FA TOTIY covering the following described property in Weld County, Colorado, to-wit: Northeast-quarter (NW4) of Section Two (2) , Township Six (6 ) North , s Range Sixty-seven (67) West of the 6th P . M. , Weld County , Colorado be recommended (favorably) (mnfryzwpkyk to the Board of County Commission- ers for the following reasons: To install sewage facilities in the T wn of Severance . Subject to meeting all State and Federal Regulations and approval of the Law Ditch Co . Motion ' bconded by , J Ben Nix Vote: For Passage: Glann...An.de.rs.on... Against Passage: . Bill J-_.. gen....lax John....Watson The Chairman declared the Resolution passed and ordered that a Certified Copy be forwarded with the file of this case to the Board of County Commissioners for further proceedings. pc I I14 l PC-Z-005 720438 CERTIFICATION OF COPY I, Dorothy Chlanda , Recording Secretary of Weld County Planning Commission, do hereby certify that the above and foregoing Resolution is a true copy of. Resolution of Planning Commission of Weld County, `Colorado, adopted on Nov . 21 , 1972 , and recorded in Book No. I I I , Page No. , of the proceedings of said Planning Commission. Dated this ., ?nd... day of Nov . , 1972 , Recording Secretary, Weld County Planning Commission pC-2-006 Hello