Loading...
HomeMy WebLinkAbout20222320.tiffUSE BY SPECIAL REVIEW (USR) APPLICATION FOR PLANNIN (DEPARTMENT USE; DATE RECEIVED: AMOUNT $ CASE # ASSIGNED: PLAINER ASSIGNED: APPLICATION RECEIVED BY P OPERTY INFORMATION Is the property currently in violation? ■ No / Yes Violation Case Number 20,120-00212 Parcel Number: 3 I 1- r 3 .. 0 0 0- 0 4 5 Site Address: 8711 County Road 23, Fort Lupton, Colorado 80521 Legal Description: Pt. Ei Section: 23 , Township 2 N, Range 67 W Zoning District: AG Acreage: 515 Within subdivision or townsite? L No !acs Name: Water (well permit #>" or water district tap ): N/A Sewer (On -site wastewater treatment system permit sewer account #): NIA Flocdplain 0 No f Yes Geological Hazard iI No Cfres Airport Oveday No Yes PROPERTY OWNERS) Name: Corr and Traci Inure Company: Phone : 303-204-1360 Email: &l notw:t@ aaLcom Street Address: 8711 County Road 23 City/State/Zip Code: Fort Lultot. Colorado 8062 Name: Company: Phone #: Street Address: City/Stateilip Code: Email: APPLICANT/AUTHOR( ED AGENT (Authodzauon Farm must be included rf there is an Author/z Agent) Name: Adam Davenport Company: Diamond '1' :lea -ices, Inc Phone #: 720-627-6151 Email: a iarsr.davcnport, dtscMces.com Street Address: 1501 Washington Avenue, list C-1 City/State/Zip Code: Golden, Colorado 8040i I e) hereby depose and state under penalties of perjury that all statements;, propels, and/or plans submitted with ur contained within the application are true and correct to the best of my (our) knowledge. All fee owners of the property must sign this application. If an Authorized Agent signs, an Authorization Form signed by all fee owners must be included with the application. If the fee owner is a corporation, evidence must be inducted indicating the signatory has the legal authority to sign Ear the ...ration. Print / Print ,C 04/04/2022 Dte Signature Vanessa Ingalls Date DEPARTMENT OF PLANNING AND BUILDING DEPARTMENT OF PUBLIC HEALTH AND ENVIRONNMENT 1555 NORTH 17TH AVENUE GREELEY, CO 80631 AUTHORIZATION FORM FOR BUILDING, PLANNING AND HEALTH DEPARTMENT PERMITS AND SERVICES I, OA/err/0CA Ord OfThit)) titniCe (Owner - please print) give permission to (Applicant/Agent — please print) to apply for any Planning, Building or Health Department permits or services on our behalf, for the property located at: x, ..71 Legal Description: ip Subdivision Name: of Section step/iv t Property Owners Information: Applicant/Agent Contact Information: D �z) Township N, Range (P1W &j(5t?uJCJt9t Lot 13 ?SD) E-mail: E -Mail: Block CSXMD4CJ_Jwrcw! , t,Drw-, e wkay---) Email correspondence to be sent to: Owner El ApplicantlAgent EL8oth 1.9 Postal service correspondence to be sent to: (choose only one) Owner El Applicant/Agent Additional Info: Owner Signature: Owner Signature: Date: 113)/1 2,2 C', c�C 7/29/2019 5 Use By Special Review Planning Questionnaire Explain the proposed use and business name. Since 2017, Diamond I Services, Inc., a local woman owned small business ("Diamond T"), has utilized approximately 5 acres of the 53.5 -acre subject property (the {`Property") for an oilfield equipment laydown area pursuant to a written lease agreement. iamond T rents equipment and provides services to the oil and gas industry in Colorado, Wyoming, Pennsylvania, Texas, and New Mexico. Diamond T's customers in Colorado are exclusively located in the DJ Basin, in close proximity to the Property. As such, it utilizes the laydown area to store items when not on rent to their customers. Typical items include rig mats, pickup trucks, light towers, tanks, loaders, centrifuge units, and related equipment. 2. Explain the need for the proposed use. Storing and staging equipment in close proximity to iamond T's customer locations in the DJ Basin reduces traffic, emissions, and improves safety. In addition, Diamond T's use of the subject property has provided supplemental income to the Property owner since 2017. 3. Describe the current and previous use of the land. The Property is 53.5 acres and is located in rural Weld County. There are oil wells and a tank battery already existing on the Property; new oil wells are being drilled in the area adjacent to and in conjunction with agricultural land. The Property contains the owners' primary residence, stables, barn, and associated out buildings. escribe the proximity of the proposed use to residences. Other than the owner's residence — which is on the opposite side of the Property — there are no nearby residences. Describe the surrounding land uses of the site and how the proposed use is compatible with them. The laydown yard area is extremely difficult to see from Weld County Road 23, the nearest public road. The laydown area is in the NW corner of the Property, along an irrigation ditch and fencerow. The laydown area is at the end of a private, interior road, behind an existing oil well, tank battery, and the Property owner's horse stables. As previously described, the area around the Property is currently, and has historically been, a mixture of agriculture and oil and gas development. As will be seen later in this application, Diamond T's laydown yard area is kept clean, orderly, and does not pose a nuisance to either the Property owners or any other adjacent property owner. In short, Diamond T's use of a small portion of the Property is consistent with current and historic land use patterns in the area. 6. Describe the hours and days of operation (i.e. Monday thru Friday 8:00 a.m. to 5:00 p.m.). The approximately 5 acres utilized by Diamond T for equipment staging and storage is not gated separately from the rest of the Property and there are no set operating hours. Though there are occasions when equipment is moved in or out of the area on the weekends, most of the use is during daylight hours, Monday -Friday. 7. Describe the number of employees including full-time, part-time and contractors. If shift work is proposed, detail number of employees, schedule and duration of shifts. For the vast majority of the time, there is no one in the area as it is for storage of items not in use. Depending on the need to mobilize equipment, there may be 3-5 individuals loading or unloading equipment. 8. Describe the maximum number of users, patrons, members, buyers or other visitors that the site will accommodate at any one time. Same as previous. 9. List the types and maximum numbers of animals to be on the site at any one time (for dairies, livestock confinement operations, kennels, etc.). There are no animals or livestock involved in Diamond T's use of the Property for intermittent equipment storage. 10. List the types d number of operating and processing equipment. Not applicable. Examples of typical equipment stored on the Property are provided in Question 1. 11. List the types, number and uses of the existing and proposed structures. There are no permanent structures associated with Diamond T's use of the Property. There are several conex units currently on the property that are used for parts storage. 12. Describe the size of any stockpile, storage or waste areas. Diamond T does not maintain any stockpile or waste storage areas on the Property. Diamond T uses approximately 5 -acres in the NW corner of the 53 -acre Property to store equipment when not in use. 13. Describe the method and time schedule of removal or disposal of debris, junk and other wastes associated with the proposed use. In the past, when needed, Diamond T has rented roll off dumpsters to dispose of trash. For example, when new equipment is delivered to the laydown area, occasionally it contains packing material that can be disposed of at local landfills. When Diamond T's use of the Property comes to an end, Diamond T will remove any remaining equipment in an expeditious manner. 14. Include a time -table showing the periods of time required for the construction of the operation. Not applicable. 2017. iamond T has utilized the same 5 -acre area for equipment storage since 15. Describe the proposed and existing lot surface type and the square footage of each type (i.e. asphalt, gravel, landscaping, dirt, grass, buildings). The 5 -acre area utilized by Diamond T was and is flat and covered by pre-existing, native grasses. Diamond T coordinated with the Property owner to provide additional gravel to the interior road to access the 5 -acre area. 16 How many parking spaces are proposed? How many handicap -accessible parking spaces are proposed? No parking spaces - handicapped or otherwise - currently exist, nor are any proposed. 17. Describe the existing and proposed fencing and screening for the site including all parking and outdoor storage areas. The Property is enclosed by a fence along its exterior boundary. There is a cattle guard at the entrance but no gate. The laydown area is not enclosed in any kind of interior fencing and none is proposed at this time. Similarly, there is no screening and none is proposed at this time because the laydown area is difficult if not almost impossible to see from WCR 23 or adjacent properties. The Notice of Intent to Proceed sent by the Department to the Property Owners on December 29, 2020 contains several photos that appear to have been taken from somewhere off the Property. The photos actually demonstrate how difficult the area is to see from adjacent properties as the person who took the photos appears to have had to zoom in considerably to only see the very tops of various pieces of equipment. Moreover, the existing oil well and tank battery all but block any view of the storage area from WCR 23, as the storage area is behind the tank battery and also the Property owner's horse stable. In sum, neither Diamond T nor the Property owners believe any screening would be effective to block the view of the storage area any more than what is provided by existing structures and existing natural terrain. 18. Describe the existing and proposed landscaping for the site. Same as previous. The 5 -acre storage area is itself flat but is blocked from adjacent properties by an irrigation ditch to the Southwest, a tree line fencerow to the west, a tank battery and to the East, and a field and cattle feedlot to the North. 19. Describe reclamation procedures to be employed as stages of the operation are phased out or upon cessation of the Use by Special Review activity. So as to provide the Property owners with as much flexibility when Diamond T's use of the Property ceases, Diamond T has not made any surface improvements to the 5 -acre area such as rocking or paving. If needed or desired by the Property owners upon Diamond T ceasing to use the laydown area, Diamond T's right-of-way construction division is fully capable of decompaction and reseeding, again, if necessary. 20. Describe the proposed fire protection measures. There are no specific fire protection measures currently in place and none are proposed. All of the Diamond T's operable equipment contains fire extinguishers that are required by its customers. 21. Explain how this proposal is consistent with the Weld County Comprehensive Plan per Chapter 22 of the Weld County Code. The author of this document is very much familiar with Weld County, having grown up in Windsor, Colorado and after graduating from law school, clerking in the Weld County District Court in Greeley. He has seen firsthand the effort needed to balance private property rights against the pressures of rapid urbanization and increasing energy exploration activity. Diamond T's use of a small portion of the Property is consistent with Weld County's Comprehensive Plan because it satisfies all of the goals of the Plan itself. The laydown yard does not take any arable land out of production and utilizes land that has already been subdivided and developed, including oil wells and associated facilities; The owners desire to allow Diamond T to utilize a small portion of their Property for use as a laydown yard and provides supplemental income; The laydown yard is located away from nearest rapidly growing area, Fort Lupton; The location of the laydown yard on the Property keeps oilfield traffic off of and out of populated areas, reducing some of the pressures of development activity; and Similarly, the location of the laydown yard close to its customers drilling activities reduces emissions from truck traffic. 22. Explain how this proposal is consistent with the intent of the zone district in which it is located (Intent statements can be found at the beginning of each zone district section in Article III of Chapter 23 of the Weld County Code.) The Property is located in the Agricultural zone district. "The intent of the agricultural Goals is to support all forms of the agricultural industry and, at the same time, to protect the rights of the private property owners to convert their agricultural lands to other appropriate land uses." Section 22-2-10(B). The Code also recognizes the historic importance of the energy industry in the County: "[e] traction of natural resources is an important part of the economy of the County. Such extraction operations should minimize the impacts to agricultural lands and agricultural operations." As set forth in the answer to question 21, above, Diamond T's use of a small portion of the previously subdivided land does not take any agricultural land out of production and is consistent with the Code's goals of protecting existing agriculture but respecting ag property owners' right to develop all or a portion of their land for consistent other uses. The equipment stored on the Property is similar to other heavy machinery located on any adjacent farm parcel or drilling location. 23. Explain how this proposal will be compatible with future development of the surrounding area or adopted master plans of affected municipalities. Diamond T is unaware of any adopted master plans from any municipalities in the area of the Property. 24. Explain how this proposal impacts the protection of the health, safety and welfare of the inhabitants of the neighborhood and the County. As explained above, locating Diamond T's equipment close to its customer's drilling operations reduces emissions, truck traffic on high utilization roadways, and away from municipal areas. 25. Describe any irrigation features. If the proposed use is to be located in the A Zone District, explain your efforts to conserve prime agricultural land in the locational decision for the proposed use. As explained above, Diamond T's use of a small portion of the Property does not take any agricultural land out of production or even infringe upon any current adjacent agricultural uses. The only "irrigation feature" is an irrigation ditch that forms the SW border of the Property but does not deliver irrigation water to the Property. Diamond T's storage of equipment adjacent to the irrigation ditch does not impact the ditch's operation in any way and Diamond T ensures that no items are stored in the right-of-way of the -itch. 26. Explain how this proposal complies with Article V and Article XI of chapter 23 if the proposal is located within any Overlay Zoning District (Airport, Geologic Hazard, or Historic Townsites Overlay Districts) or a Special Flood Hazard Area identified by maps officially adopted by the County. This question is not applicable because the Property is not located in any Overlay Zoning District. 27. Detail known State or Federal permits required for your proposed uses and the status of each permit. Provide a copy of any application or permit. Diamond T is not aware of any State or Federal permits required to use a portion of the Property for an equipment laydown yard. Diamond T is a certified woman owned small business lawfully licensed to business in the states in which it operates, including Colorado. Use by Special Review Public Works Questionnaire 1 1'escribe the access location and applicable use types (i.e. agricultural, residential, commercial/industrial, and/or oil and gas) of all existing and proposed accesses to the parcel. Include the approximate distance each access is (or will be if proposed) from an intersecting county road. State that no existing access is present or that no new access is proposed, if applicable. The Property and the existing oil well infrastructure are accessed from a single, existing access point on the West side of CR 23. The Property is accessed from CR 23 between CR 20 to the North and CR 18 to the South. The access to the Property is approximately 1/3 -mile South of the intersection of CR 23 and CR 20, and approximately % of a mile to the intersection of CR 23 and CR 18. 2. Describe any anticipated changes to an existing access, if applicable. There are no anticipated changes to the existing access to the Property. 3. Describe in detail any existing or proposed access gate including its location. There are no existing or proposed access gates to the Property. There is a cattle guard and culvert ert that span the entrance. 4. Describe the location of all existing accesses on adjacent parcels and on parcels located on the opposite side of the road. Include the approximate distance each access is from an intersecting county road. Distance fro i Access t;f Nearest Intersections t4on11 The Property is accessed from CR 23 between CR 20 to the North and CR 18 to the South. The access to the Property is approximately 1/3 -mile South of the intersection of CR 23 and CR 20, and approximately % of a mile to the intersection of CR 23 and CR 18. Other Adjacent Property Access There is a lease road access on the opposite side of CR 23 (East side), approximately 400 ft. to the South of the access to the Property. This road appears to only be used to access an existing oil well and tank battery. There is another lease access road approximately 700 feet to the South of the foregoing road. It is unclear whether this access is still used. The adjacent property to the South is accessed from the same side of CR 23 (West), approximately 1/3 of a mile to the South. Describe any difficulties seeing oncoming traffic from an existing access an any anticipated difficulties seeing oncoming traffic from a proposed access. There are no difficulties seeing oncoming traffic from the existing access. 6. Describe any horizontal curve (using terms like mild curve, sharp curve, reverse curve, etc.) in the vicinity of an existing or proposed access. There is a mild curve in CR 23 toward the East approximately %-mile from the existing access to the Property where CR 23 skirts Coal Ridge Waste Reservoir and intersects with CR1 . There are no other curves in the vicinity of the existing entrance to the Property. 7. Describe the topography (using terms like flat, slight hills, steep hills, etc.) of the road in the vicinity of an existing or proposed access. CR 23 is flat in the vicinity of the existing access to the Property. Public Works - Site Drainage Diamond T and the Property owners believe that Diamond T's use of the Property is exempt from drainage report and detention pond design criteria because Diamond T's use of the Property does not increase the imperviousness of the site. Exemption Narrative 1. Any existing and proposed improvements to the property. Diamond T has not, nor will it in the future, construct any improvements on the Property. 2. The exception being requested for consideration. Code Section 8-11-40.1.8.8. which exempts, "[d]eveloprnent of sites where the change of use does not increase the imperviousness of the site*" where the water originates if it flows on the property from an off -site source. Diamond T has not observed any water flowing onto the property from adjacent parcels. 4. Where the water flows as it leaves the property. iamond T has not observed any water flowing onto or across the property. 5. The direction of flow across the property. Diamond T has not observed any water flowing onto or across the property. 6. Previous drainage problems with the property, if any. Diamond T has not observed any drainage problems in the approximately 5 -acre parcel used as an equipment laydown area. 7. The location of any irrigation facilities adjacent to or near the property. Coal Ridge Ditch borders the Property to the West/Southwest. The ditch is at a higher elevation than the laydown area, sitting above the area utilized by Diamond T. As a result, no water is able to drain from the Property into the ditch. 8t Any additional information pertinent to the development. Diamond T utilizes approximately 5 acres of the Property. The portion utilized by Diamond T is more or less flat and does not have any drainage issues. In order to reduce the long-term impacts of Diamond T's use, no grading or other surface improvements have been made and none are anticipated unless required in order to receive USR approval. Preliminary Traffic Impact Analysis Traffic Narrative 1. Describe how many rauntrips/day are expected for each vehicle type: Passenger Cars/Pickups, Tandem Trucks, Semi-Truck/Trailer/RV (Rountrip = One (1) trip in and One (1) trip out of site). Diamond T's use of a portion of the Property is intermittent. On average it is estimated that there is one to two roundups for a pickup and semi -truck. 2. Describe the expected travel routes or haul routes for site traffic. Most haul loads access the Property via I-25 to Highway 52 east to CR 23 north with some utilizing Highway 85 to CR 18 west to CR 23 north to the Property. Describe the travel distribution along the routes (e.g. 50% of traffic will come from the north, 20% from the south, 30% from the east, etc.). It is estimated that the distribution of access via 1-25 and Highway 85 is evenly split, 50% each. 4. Describe the time of day that you expect the highest traffic volumes. It is difficult to predict on any given day when the highest volume of traffic related to Diamond T's use will occur. For numerous safety reasons, Diamond T makes every effort to utilize the Property during daylight hours only, Monday -Friday. Use by Special Review Environmental Health Questionnaire 1 l iscuss the existing and proposed potable water source. If utilizing a drinking water well, include either the well permit or well permit application that was submitted to the State Division of Water Resources. If utilizing a public water tap, include a letter from the Water District, a tap or meter number, or a copy of the water bill. Diamond T does not access or desire any potable water source in relation to its use of the Property as an equipment laydown yard. 2. Discuss the existing and proposed sewage disposal system.What type of sewage disposal system is on the property? If utilizing an existing on -site wastewater treatment system, provide the on -site wastewater treatment permit number. (If there is no on -site wastewater treatment permit due to the age of the existing on -site wastewater treatment system, apply for a on -site wastewater treatment permit through the Department of blic Health and Environment prior to submitting this application.) If a new on -site wastewater treatment system will be installed, please state "a new on -site wastewater treatment system is proposed." (Only propose portable toilets if the use is consistent with the Department of Public Health and Environment's portable toilet policy.) Since Diamond T's use of the Property as an equipment laydown yard is sporadic and when in use, of limited duration, there are no sewage facilities necessary. . If storage or warehouseing is proposed, what type of items will be stored? Diamond T's oilfield equipment is stored at the Property when not on rent to Diamond T's customers. Such equipment includes but is not limited to, open and closed top tanks, loaders, light towers, 8 x 16 ft. containment mats, and centrifuges. 4. Describe where and how storage and/or stockpile of wastes, chemicals, and/or petroleum will occur on this site. All equipment is cleaned on Diamond T's customer location prior to being brought back to the Property. As such, there are no wastes or chemicals stored on the Property. 5. If there will be fuel storage on site, indicate the gallons and the secondary containment. State the number of tanks and gallons per tank. There will not be any fuel stored on the Property. 6. If there will be washing of vehicles or equipment on site, indicate how the wash water will be contained. No, all equipment stored is cleaned by R iamond T's customers on their location prior to the equipment being returned to the Property. 7. If there will be floor drains, indicate how the fluids will be contained. There are no improvements on the Property associated with Diamond T's use of the Property as an equipment laydown yard. 8. Indicate if there will be any air emissions (e.g. painting, oil storage, etc.). There will be no air emissions associated with iamond T's use of the Property for equipment storage. 9. Provide a design and operations plan if applicable (e.g. composting, landfills, etc.). Diamond T does not believe this question is applicable to equipment storage uses. 10. Provide a nuisance management plan if applicable (e.g. dairies feedlots, etc.). Diamond T does not believe this question is applicable to equipment storage uses. In any event, Diamond T does not believe any of its activities would constitute a nuisance. 11. Additional information may be requested depending on type of land use requested. Diamond T welcomes any additional questions or information requests. Additional Planning Checklist Items O&G Facilities, Pipelines, Ditches, etc Pipelines and Overhead Power Lines (in right-of-way along CIS 23) There are pipelines and power lines that run along CR 23, the Easterly boundary of the Property. Those facilities are maintained by the following entities: DJ South Gathering, LLC Kerr McGee Anadarko Gathering United Power (overhead power lines) Irrigation Facilities The Coal Ridge Ditch borders the West side of the Property. Diamond T is aware that an access and maintenance easement is afforded the owners and operators of irrigation ditches in Colorado as a matter of law. As such, tamond T does not place any equipment in this easement area. O&G Facilities There are two KP Kaufman wells and Anadarko facilities for a well on an adjacent property, as follows: KP Kaufman Company, Inc., Gerhardt B #6 well — located in the center of the Property; KP Kaufman Company, Inc., Gerhardt Marie 1/9 well located about mid -property on the Northern Property line (closest facility to Diamond T's laydown area); Kerr McGee, Graner 1-23A production facilities, located next to the entrance road in front of the barn. Flowlines The Property owners contacted the owners of the foregoing facilities and inquired about location of flowlines or any other information. The Property owners were informed that the flowlines are "line of site from the wells to the facilities." No additional information was available. Surface Use Agreements There are no surface use agreements between the entities listed in the foregoing section and the Property owners. Lighting Plan No lighting plan has been submitted with this application because Diamond T does not intend to utilize the Property after sunset or otherwise light the laydown area. Sign Plan No sign plan has been submitted with this application because iamond T has not, and does not plan to place any signage related to its equipment storage. There is a small sign along the interior portion of the access road pointing away from the Property owners' residence and toward the laydown area toward the back of the Property. Landscape and Screening Plan No landscaping and screening plan was submitted with this application because the area used by Diamond T for equipment storage is difficult to see from adjacent parcels and especially from CR 23. The laydown area is approximately I from CR 23 and behind the Property owners' barn and an existing tank battery, along the back property line, in front of a fence row with large trees and other native vegetation. Moreover, there are simply very few other people in close proximity that could see the laydown area. The Property is bounded to the North by a field, and then a cattle feed lot; the Property owners' barn, stable, and residence blocks the view from the South. To the west, the vegetated fence row blocks any view from the West. Decommissioning Plan Diamond T does not believe any formal decommissioning plan is necessary since there are no improvements associated with its use. When Diamond T ceases to use the Property, it will simply remove its equipment. In the event the Property owners desire any type of decompaction or reseeding, Diamond T's Construction unit can self -perform such work. Corn m unication Plan Diamond T does not believe any formal communication plan is necessary for its use of a portion of the Property as a laydown yard. The Property owners have the ability to contact several different Diamond T personnel 24 -hours per day, 7 days per week if necessary. Notice of Inquiry Forms The author was able to discuss this application with Todd Hodges with the City of Ft. Lupton and the completed NOI is provided below. Unfortunately, the author has not been able to reach anyone with the City of Firestone. Below is the email transmitting the NOI form to the City of Firestone Planning epartment on January 8, 2021. The author followed up by telephone the same date but has not received a return call or response to his email. The author followed up with the Planning Department by email on January 20, 2021. 464 (2-E- 213 le l ci e,rne,1%,,INcIJ co USE BY SPECIAL REVIEW (USR) PROCEDURAL GUIDE DEPARTMENT OF PLANNING SERVICES 1555 N. 17TH Avenue, Greeley, CO 80631 + 970-400.-6100 J vvvvw_ eld'aov.com Note: A Pre -Application Request Form must be submitted to the Department of Planning services prior to the submittal of a USR application. Note: 1041 land uses require a separate application. Submit all the application components as separate documents in PDF format, in the order ouut n d in the checklist below. S PLANNING REQUIREMENTS CHECKLIST T Application Form. (See attached). Authorization Form, if applicable. (See attached). beed identifying the surface estate ownership interest in the property and relevant Lease documents. seri dar Q 0 °PP LAI< le IS Bhafttj W ILA RAIIS T'c+ 01 \P 006zofte Wil-AEAtz- Pir:r Articles of Organization or Incorporation documents if the owner is a business entity. Includ e Statement/Delegation of Authority documentation. —> ,r L c--,k-rVu )414_ Trustee documents if the owner is a Trust. 1erte"St1/4 ''A Certificate of Conveyances Title <COG) prepared by a Title Company within 30 days. -4 o riageoLik "Ark, A signed Statement of Taxes from the County Treasurer showing subject property. The Statement shall be from the current tax year Completed Planning Questionnaire. (See attached). freer Draft USR map. (See attached for map requirements.) ceen . Once signed, the COG expires ;Vt._ iaicirialkS42 PI sr** Ii t i_s no delinquent property taxes for - t.i.~ Lighting Plan following the standards set forth in Chapter 23, Article II, Division 4 and the Dark Sky Policy, if applicable. Sign Plan detailing type, size and number of proposed signs with images following the stand ards lord s set forth in Chapter 23, Article IV, Division 2 and Appendices 23-C through E if applicable. � pp Landscape and Screening Plan detailing the existing and proposed landscaping, p gt property maintenance, installation schedule, irrigation method,, security and/or privacy fencing, g, trash enclosure, portable toilet screening, etc. if applicable. Soil Report of the site prepared by the Natural Resource Conservation Service or a soils engineer, g eer, p/1& Communication or Decommissioning Plan, if applicable. Emergency Contact Form. (See attached). Notice of Inquiry (NOI) Form from a municipality or municipalities if the site i i . � s to is located within an inter overnmentar Agreement (IGA) boundary or a Coordinated Planning Aire. d"� fi .� g g erraer�t (cPA) oundaryf if applicable. — iQACSIOONSE- /1OBuffer Report, signed, of the n - _ p g es, addresses and parcel numbers of the surrounding property owners within 500 feet of the property. Once signed,the buffer report expires within 30 days.—) comar unity meeting sign in sheet, minutes, and summary (optional). 0c The names and addresses of any owner, operator of any oil and gas facilities, irrigation ggatio n 1 ditches/laterals, pipelines, overhead lines, railroad, etc_ on the property, if applicable. a Iset>P4lesseelA tidies A co of any Surface Use Agreement with mineral owners associated with the subject property,1 stipulating that the oil andgas activities on property the subject property have been adequately incorporated into the design of the site in accordance with Section 23-2-160.1 ' c' � '°-a`Fteti1/4 Application � - - ��' fee. A b0 �a investigation fee is required if this is application is in response to a violation. Continued on the next page USE BY SPECIAL REVIEW (USR) PROCEDURAL GUIDE PUBLIC WORKS REQUIREMENTS CHECKLIST Completed Public Works Questionnaire. (See attached). A Preliminary Drainage Report or Drainage Narrative. (See attached drainage requirements). A Traffic Impact Study (or Traffic Narrative). (See attached traffic requirements). id (- MS4 Requirements, if applicable. (A Preliminary drainage report providing water quality will be required for the completeness review if the project site falls within an MS4 area.) ENVIRONMENTAL HEALTH REQUIREMENTS CHECKLIST Completed Environmental Health Questionnaire. (See attached). Water Supply Documentation. Example: A letter or bill from a water district or municipality, or a well permit or permit application from the State Division of Water Resources. Provide a statement if upgrading the water source from agricultural or residential usage to commercial or industrial. Sewage Disposal Documentation. Example: An Onasite wastewater treatment system permit or application or bill from a sanitary sewer district. Noise Study including a noise abatement plan documenting the methods to be utilized to meet the applicable noise standard, as determined by Environmental Health. 0 Waste Handling Plan, as determined by Environmental Health, 0 Dust Abatement Plan, as determined by Environmental Health. 0 Engineering, Design and Operations Plan, as determined by Environmental Health. 0 Nuisance Abatement Plan (pest, manure, etc.), as determined by Environmental Health. Any other item(s) deemed necessary to process the Use by Special Review application may be requested by the Departments of Planning Services, Public Works and Public Health and Environment. SUPPLEMENTAL REQUIREMENTS Applications for the following USR types require additional submittal requirements as detailed in Chapter 23, Article IV of the Weld County Code, as amended. Mines Feed lots Kennels • Solar Facilities • Wind Generators Outdoor Shooting Ranges • Telecommunication Towers ▪ Residential Therapeutic Center • Solid or Hazardous Waste Disposal Facilities Organic Fertilizer Production and Composting Facilities Supplemental Requirement Submittal Packet, if applicable. Notice of Inquiry Development within an Intergovernmental Agreement Urban Growth Boundary Pre -application Case # PRE2O-O1g4- Cate of Inquiry 11/10/2020 Municipality with CPA or IGA Town of Fort Lupton Name of Person n Inquiring Cory Knote Property Owner Same Planner Chris Gathman Planner Phone Number 970-400-3537 Planner Email Address cgathman@weld;gov.com Legal Description Lot B Recorded Exemption RE -1541; located in Part E2 of Section 23, T2N, R67 of the 6th PM Parcel Number 131123000045 Nearest Intersection West of and adjacent to CR 23 and approximately 1,300 feet south of CR 20 T e of In ul p ( SR) for an oil and gas support facility (storage of equipment associated with oil and gas production, workover and production) The above person met with County Planning staff about developing a parcel of land inside your designated Intergovernmental Agreement/Coordinated Planning Agreement Boundary. In accordance with the IGA, found in Chapter 19 of the Weld County Code, the applicant has been notified of the IGA and the County will not accept an application for development sooner than 21 days from the date they contact you unless this signed form is returned with the box checked below indicating you do not wish to pursue annexation at this time.You are asked to sign below to acknowledge that the applicant has contacted you. Date of Contact with Municipality: 1 15 2021 O We are not interested in pursuing annexation with this applicant at this time. We request 21 days from the date of contact to pursue annexation with this applicant. We discussed the potential for annexation with the applicant's representative and they have indicated They are not interested in annexation at this time. We will respond appropriately in the referral process. Todd A. Hodges Planning Director 1 15 2021 Signature of Municipality Representative Title Date Weld County Planning Department 1555 N 17th Aver Greeley, CO 80631 -- (970) 400-6100 - (970) 304-6498 Fax From: To: Subject: Date: Attachments: Adam Davenport Planning@firestoneCO.gov RE: NOI - Knote Diamond T Wednesday, January 20, 2021 12:21:00 PM image001.pna Good morning, Following up on my email from a couple weeks ago, below. The property owners are not interested in being annexed into Firestone. Please let me know if you need any additional information to send back the completed NOI for this application. Best, Adam Adam C. Davenport General Counsel Diamond T Services, Inc. 1501 Washington Ave., -1 Golden, Colorado 80401 Cell: Tele: (720) 627-6151 Fax: (720) 216-2055 adam. davenportdtservices. corn 9,7 fliamilnil7 This electronic transmission contains information which is intended for the use of the individual to whom it is addressed, d which may contain information that is privileged, confidential, and/or otherwise exempt from disclosure under applicable law. If the reader of this message is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, any disclosure, dissemination, distribution, copying, or other use of this communication or its substance is prohibited. If you have received this communication in error, please notify me and destroy the original transmission. Thank you. From: Adam Davenport Sent: Friday, January 8, 2021 3:08 PM To: Planning@firestoneCO.gov Subject: NOI - Knote Diamond T Good afternoon, I am working with a property owner in Weld County to obtain a Use by Special Review permit for an equipment laydown yard used by our company. We have been told by Weld County that we need to send the Town of Firestone the attached Notice of Inquiry. Please let me know if you have any questions or if this is not the proper department to contact. Thank you in advance for yourt me. Best, Adam Adam C. Davenport General Counsel Diamond T Services, Inc. 1501 Washington Ave . , -1 Golden olorado 80401 Cell: Tele: (720) 627-6151 Fax: (720) 216-2055 adam.davenport ,dtserviees. com (QU/amantiT This electronic transmission contains information which is intended for the use of the individual to whom it is addressed, and which may contain information that is privileged, confidenfial, and/or otherwise xempt from disclosure under applicable law. If the reader of this message a is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, any disclosure, dissemination, distribution, copying, or other use of this communication or its substance is prohibited. If you have received this communication in error, please notify me and destroy the original transmission. Thank you. Certificate Of Taxes Due Account Number R0142.394 Parcel 131123000045 Assessed To KNOTE CORY A 13711 COUNTY ROAD 23 FORT LUPTON, CO 80621-8921 Certificate Number 229702 Order Number Vendor ID 16 BLACK KNIGHT INC 601 RIVERSIDE AVENUE JACKSONVILLE, FL 32204 Legal Diption. PT E2 23-2-67 LOT B REC EXEMPT RE -1.541 (_89R_85DM) 8711 23 CR WELD 00000 Sites Address 8711 COUNTY ROAD 23 WELD Year Tax Tax charge Adjustments $0.00 :Fees $0.00 $1,976.50 2020 $1,976.50 $0.00 $0.00 Total Tax Charge Grand Total Due as of 01/19/2021 Tax Billed at 2020 Rates for Tax Area 3440 - 3440 Authority WELD COUNTY SCHOOL DIST RE8 NORTHERN COLORADO WATER (NC FORT LUflON FIR FORT LUPTON FIRE (BOND 2022 AIMS =OR COLLEGE HIGH PLAINS LIBRARY Taxes Billed 2020 * Credit Levy $1,976!.50 Mill Leer 15.0380000* 11.5260000* 1.0000000 9.2970000 0.3 620000 61 05 0000 3.18.10000 Amount Values $5.53.41 AG -GRAZING LAND $681.76 AG -ALL OTHER LAND $36.80 FARMJRANCH $342.13 RESIDENCE -IMPS $1332 ALL OTHER AG IMPS Actual $1,031. $5,000 $318,614 $42:308 $1,976.50 Assessed $300 $1,450 $22,780 $12,270 $232.02 Total $366,9!53 $117.06 533090000 $1,976.50 $36,800 All payments made are subject to final bank clearance. WARNING - THIS TAX CERTIFICATE. DOES NOT WARRANT ANY TAXES OWED ON UNDERLYING ACCOUNTS, INCLUDING PARENT OR SIBLING ACCOUNTS. ALL TAX LIEN SALE AMOUNTS ARE SUBJECT TO CHANGE DUE TO ENDORSEMENT OF CURRENT TAXES BY THE LIIENHOLDER OR TO ADVERTISING AND DISTRAINT WARRANT FEES_ CHANGES MAY OCCUR AND THE TREASURER'S CFFICIE WILL NEED TO BE CONTACTED PRIOR TO REM IITTANCE_ TAX LIEN SALE REDEMPTION AMOUNTS MUST BE PAID BY CASH OR CASHIER'S CHECK POSTMARKS ARE NOT ACCEPTED ON TAX LIEN SALE REDEMPTION PAYMENTS_ PAYMENTS MUST BE IN OUR CFFIICF AND PROCESSED BY THE LAST BUSINESS DAY OF THE MONTH. SPECIAL TAXING DISTRICTS AND THE BOUNDARIES OF SUCH DISTRICTS MAY BE ON FIILEWITH THE BOARD OF COUNTY COMMISIONERS, THE COUNTY CLERK, OR THE COUNTY ASSESSOR_ This certificate does not include land or improve:ments assessed under a separate account number, personal property taxes, transfer tax or misc. tax colluded on behalf of other entities, special or local improvement districtassessments or mobile homes, unless specifically mentioned_ I.r the undersigned, do hereby certify that the entire amount of taxes due upon the above descr bed parcel of real property and all outstanding sales for unpaid taxes as shown by the records In my office from which the same may still be redeemed with the amount required for redemption are as noted herein_ lin witness whereof, I have hereunto set my hand and seal_ TREASURER, WELD COUNTY, John R_ Lefebvre, Jr. 1.400 N_ 17th Avenue Greeley, CO 80631 (970) 400-3200 Jan 19, 2021 3:36:39 PM Page 1 of 1 First Amendment Warehouse and Storage Agreement It is agreed and made effective this 29' day of July 2022 to amend the Warehouse and Storage Agreement ("Agreement") between TLK Mini Ranch, LLC ("Company") and Diamond T Services, Inc. ("Customer") dated January 31, 2017. The original Agreement does not address if the Agreement is transferable to the new owners should the Property at 8711 County Road 23, Ft Lupton, Colorado 8Q621 be conveyed. The Company and theCustomer have agreed herein that the Agreement will be transferable to any future new owners of the Property. Company: TLK Mini Ranch. LLC Customer: Diamond T Services, Inc. Zni BY; Page 1 of 12 CIVIL ENGINEERING ACCEPTED BY DEVELOPMENT REVIEW MARCH 28, 2022 PRELIMINARY DRAINAGE REPORT 8711 COUNTY ROAD 23 WELD COUNTY, CO PRE20-0194 r I L PROJECT SITE 1 !_ I 0 1 14.50m4 t'radwl. Mao corat 7 Tome of l►. CRPat a -n a 900r PREPARED BY ERICA ENGELHARD, El SENIOR PROJECT ENGINEER RAPTOR CIVIL ENGINEERING REVIEWED BY ERIC BURTZLAFF, PE PRINCIPAL RAPTOR CIVIL ENGINEERING DATE: 10/18/2021 REVISED: 03/22/2022 JOB: 21-75 Westminster, CO 80031 720.774.7736 www. raptor-eivi Isom Weld County Drainage Code Certificate of Compliance P R E20-0194 Weld County Case Number: . _ __ - 131123000045 Parcel Number: NE 1/4 SECTION 23, TOWNSHIP 2 NORTH, RANGE 67 WEST Legal Description, Section/Township/Range: - - . 01/25/2022 Date: - em Ay. 1 6I eft 'a „. m +r' .. ERIC BURTZLAFF DIAMOND T SERVICES , consultant Engineer for (Applicant), understand and acknowledge that the applicant is seeking land use approval of the case and parcel in the description above. l have designed or reviewed the design for the proposed land use set for in the application. I hereby certify, on behalf of the applicant, that the design will meet all applicable drainage requirements of the Weld County Code with the exception of the variance(s) described on the attached exhibits. This certification is not a guarantee or warranty either expressed or implied. ,. i--. - - . .- Engineer's Stamp: 1. 2. I Engineer of Record Signature Variance Request (If Appticablel Describe the hardship for which the variance is being requested. List the design criteria of the Weld County Code of which a variance is being requested. Describe the proposed alternative with engineering rationale which supports the intent of the Weld County Code. Demonstrate that granting of the variance will still adequately protect public health, safety, and general welfare and that there are no adverse impacts from stormwater runoff to the public rights -of -way and/or offsite properties as a result of the project. 1. Outfall for detention is nearly impossible on this site due to the topography. 2. A variance is being requested which allows for the use of a retention pond on this site in lieu of the currently proposed detention pond. 3. This project will propose to use a retention pond which will be sized according to county requirements and will infiltrate runoff into the Type A soils. /4-1erfs Public Works Director/Designee Name 7 Date of Signature Comments: Public _ Works Director/Designee Review (If Applicable) Signa V Approved ,46-teh ❑ Denied Department of Public Works I Development Review 1111 H Street Greeley, CO 80631 I Ph: 970-304-64961 www.weldgovi midepartmentstpubiic_worksideveloprnentjeview Page 2 of 12 CIVIL ENGINEERING TABLE OF CONTENTS: 1. INTRODUCTION 3 A. LE CATI ON ••.... •••.... •••.. •••... ••••... •••... •••... •••.... •••... ••... ••••... ••••.. •••... •••.... •••... •••......... •••.... ••... •••.O •••.3 B. DESCRIPTION OF PROPERTY C. D. ....!llOff Off Off Off Off Off ....!llOff ll................................ ... ... .. ....... ....... .. ....... PROPOSED PROJECT DESCRIPTION 00 0000***0•111 .......... IMO ... .... ... ... .......... .. ego .... ......• 3 FLOOD HAZARD 3 2. HISTORIC DRAINAGE SYSTEM A. MAJOR BASIN DESCRIPTIO B. ....................... 4 NS..••......•...•.....•••...iii....•••.....•..•iii...•••...............••••...•.....••....•••....••• SUB -BASIN DESCRIPTI0NSi••...•••...•.......••..•••...........••...•••..........•••...••.....••....••...•••..........•••...•••. 3. DEVELOPED DRAINAGE SYSTEM A. SUB -BASIN DES RI PTIONS.. •••.... •••... ••... ••••... •••..........••.... •••... •••.. ••••... ••••... ••... •••.... •••... •••... •••... •••A B. DEVELOPMENT CRITERIA REFERENCES AND CONSTRAINTS......................................................S Co HYDROLOGIC CRITERIA......................................................................................*....................S D. RET ENTIN .................flom.............................................................................................*.........S E. WATER • U ALITY..........................................O.iii....iii...i.... .... .......... ii..■iii..■.............iii.............7 4. CONCLUSIONS .........••... 5. REFERENCES...............................................................•....•....•....•..•• 6. APPENDICES ............ ... ... ... ... .. .... .... .... ... ... ... ... ... ... ... ... ............................... A. NRCS WEB SOIL SURVEY 7 B. F E IV1A FLOOD MAP . ••••... •••... •••... •••.... •••... ••... ••••... ••••.. •••... •••.....,.... •••......... •••.... ••... •••... ••••7 C. HYDROLOGIC COMPUTATIO NS••... •c......••... •••.......... •••... ••.......... •••......... •••.... •••... •••.. ••••... ••••... ••.7 D. WATER QUALITY & RETENTION CAMPLITA►Ti INNS...•••...••••...••...•••....•••.........•••...••••...••...•••....••••. E. DRAINAGE PLANS .... •.. ••... •••.... •••... •••....••... ••••... •••.. •••.... •••.... ••... •••... ••••... •••... ••.... •••..........••... •••. Westminster, Co 80031 720.774.7736 wvvw. raptor-civil.com Page 3of12 CIVIL ENGINEERING 1. INTRODUCTION RCE has prepared the following Preliminary D County Road 23, Weld County, Colorado. rainage Report for a laydown yard located at 8711 This report will demonstrate that the laydown yard does not negatively impact downstream drainage nor the adjacent properties. A. LOCATION The subject property is currently a single parcel of land addressed 8711 County Road 23, Weld County, Colorado. The subject property consists of Lot B which is 54.791 acres. The property is developed currently consists of a single-family residence along with a gravel access road and barn. The subject site is bordered to the North and South by single family parcels, the East by County Road 23 and the West by the Coal Ridge Ditch. The subject site is located within the East Half of Section 23, Township 2 North, Range 67 West of the 6th Principal Meridian within Weld County, Colorado B. DESCRIPTION OF PROPERTY Existing Topography and Ground Cover The subject site is 54.791 acres. The existing ground cover is low growing vegetation and grasses. According to USDA NRCS Custom Soil Resource website, the site is 58.8% map unit symbol number 69, Valent Sand on 0 to 3% slopes, 22.1% map unit symbol number 72, Vona Loamy Sand on 0 to 3% slopes, 8.6% rnap unit symbol number 70, Valent Sand on 3 to 9% slopes, 7.2% map unit symbol number 73, Vona Loamy Sand on 3 to 5% slopes and 3.2% map unit symbol number 35, Loup -noel Loamy Sands on 0 to 3% slopes. The site consists of 100% hydrologic soil group A. The site slopes at an average of 2% northeast towards County Road 23. No land survey was provided to RCE at the time of this report. RCE relied upon GIS topog GIS imagery and site observations to prepare the drainage plans included. C. PROPOSED PROJECT DESCRIPTION This development proposes to use approximately 5 acres for an on -site oilfield equi laydown yard. raphy, Ip D. FLOOD HAZARD The subject site is located within FEMA Firm Map Number 08123C2105E dated January 20, 2016. The site is located within Zone X defined as areas determined to be outside the 0.2% annual chance floodplain. Westminster, Co 80031 720.774.7736 www. raptor-civi I.com rent Page 4 of 12 CIVIL ENGINEERING 2. HISTORIC DRAINAGE SYSTEM A. MAJOR BASIN DESCRIPTIONS The Coal Ridge Ditch borders the property to the West. The Ditch is higher than the subject property, so no on -site runoff is conveyed to it. All runoff on -site is conveyed east towards County Road 23. B. SUB -BASIN DESCRIPTIONS While the laydown area is constructed on -site currently, RCE is analyzing the historic condition assuming pre-laydown area conditions and referring to developed as the current conditions. RCE assumes that pervious area existed in historic conditions and has analyzed accordingly. Historically, the subject site is divided into one sub -basins described as Hi in this drainage report/plan. There are no off -site flows onto the subject property. Basin Hi consists of 6.98 acres and slopes northeast towards County Road 23. This basin is historically 2.00% impervious. Basin H1 detailed information can be found below in Table 1. Table 1— Historic Summary Table Basin Area (ac) C10 110 (in/hr) Q10 (cfs) Hi 6.98 0.07 2.46 1.19 Refer to Appendix E for the Historic Drainage Plan. 3. DEVELOPED DRAINAGE SYSTEM A. SUB -BASIN DESRIPTIONS In developed conditions, the site is broken into one sub -basin described as Dl in this drainage report/plan. Basin D1 which encompasses the proposed laydown area, consists of 6.98 acres and slopes northeast towards the proposed on -site retention facility. This basin is determined to be 6.04% impervious. Basin Di detailed information can be found below in Table 1. Table 2 — Developed Summary Table • Area WO C10 C100 Flo (in/h r) Iwo (in/hr) Q10 (cfs) Q100 (cfs) D1 6.98 0.11 0.25 2.49 4.15 1.83 7.20 Refer to Appendix E for the Developed Drainage Plan. Westminster, Co 80031 720.774.7736 www. raptor-civil.com Page 5of12 CIVIL ENGINEERING R. DEVELOPMENT CRITERIA REFERENCES AND CONSTRAINTS The proposed drainage design complies with both the Weld County Engineering and Construction Criteria Manual and the Mile -High Flood District Drainage Criteria Manual. To the best knowledge of this engineer, the proposed development does not impact adjacent drainage studies. C. HYDROLOGIC CRITERIA Design Storm Frequencies P e r the Weld County Engineering and Construction Criteria Manual , the 5 and 100 -year storm events are analyzed as the minor and major storm events, respectively. Hydrologic Method Since the site is under 160 acres, the Rational Method was used to calculated runoff in this report. Flowrates were calculated using the following MHFD formulas. a) Impervious values and runoff coefficients are derived from the "Rational Method Runoff Coefficients, C -values" provided by the County. b) The one -hour precipitation is based on NOAA Atlas 14 data for the subject property. c) Time of Concentration is calculated using equations from Volume 1 Chapter 6 of MHFD drainage criteria manual for overland and channelized flows. d) The rainfall intensity was calculated using equation 5-1 from Volume 1 Chapter 5 of MHFD drainage criteria manual along with aforementioned P values. e) The peak flowrate is calculated Q= CIA. D. RETENTION This site is in the non -urbanizing drainage area. Per Weld County Code, Section 8-11-40.D., for non -urbanizing drainage areas the County requires detention of runoff from the 1-hour,100-year, storm falling on the developed site and release of the detained water at the 1 -hour, 10 -year historic runoff rate of the 1 -hour, 10 -year storm falling on the undeveloped site. 2. Per Section 5.10 of the Weld County Engineering and Construction Criteria manual, Weld County does NOT allow full spectrum detention to be used in sizing ponds. Since the proposed site has very minimal slope, an outfall pipe and structure for a detention pond is not feasible for this design. Therefore, RCE has requested a variance to design a full infiltration retention pond instead. This retention pond was sized per section 8-11-100-B.2. of the Weld County code for 1.5 times the 24 -hour, 100 - year storm plus one foot of freeboard. The required volume of 53,579 cu. ft. was found using the Modified FAA tab of the Weld County's IUD -Detention v2.35 worksheet. Volume information is given in Table 4 below. Westminster, Co 80031 720.774.7736 www.raptor-civilcom Page 6 of 12 CIVIL ENGINEERING Table 4 — Retention Facility Volume & WSEL Table Volume WSEL Ac -ft Cu -ft Ft Bottom of Facility 0 0 4927.00 100-YR 1.252 54,541 4929.30 Top of Facility 1.704 74,216 4930.30 The retention facility shall include an emergency spillway which will have buried Type VL riprap p as erosion protection. Any storm event below the 100 -year storm shall be captured in the facility and infiltrated into the native Type A soils. Storm events at and above the 100 -year storm will be released through the emergency spillway which has been sized to convey the peak 100 -year discharge at a depth less than 6 -inches. The emergency spillway embankment will also include an 8 -inch concrete cutoff wall which will be 3 -feet deep and extend 5 -feet into the embankment. This concrete cutoff wall will serve to protect publicly owned infrastructure. Refer to Appendix D for all calculations and Appendix E for details of the facility. Maintenance Routine maintenance of the retention facility is under the responsibility of the property owner. This maintenance consists of regularly scheduled mowing and trash and debris pickups for the retention facility during the growing season. This includes items such as the removal of debris/material that may be cluttering the bottom of the facility. It also includes activities such as includes weed control, mosquito treatment, and algae treatment. Inspections should be performed bi-annually to ensure the facility is functioning as designed. The western side of the facility is sloped at 10:1 side slope to allow for maintenance vehicles to access the bottom of the facility. Occasional mowing is necessary to limit unwanted vegetation and to improve the overall appearance of the facility. Native vegetation should be mowed to a height of 4 -to -6 inches tall. Grass clippings should be collected and disposed of properly. Minimum of twice annually or depending on aesthetics. Trash and debris must be removed from the entire facility area to minimize infiltration clogging and to improve aesthetics. This activity must be performed prior to mowing operations and minimum of twice annually. Noxious weeds and other unwanted vegetation must be treated as needed throughout the facility. This activity can be performed either through mechanical means (mowing/pulling) or with herbicide. Consultation with the local Weed Inspector is highly recommended prior to the use of herbicide. This should be completed as needed based on inspections. Westminster, Co 80031 720.774.7736 www. raptor-civil.com Page 7of12 CIVIL ENGINEERING E. WATER QUALITY Since this site is proposing to store oil and gas equipment, water quality will be provided for the laydown area with the proposed retention facility detailed above. 4. CONCLUSIONS This project meets the requirements of the Weld County Engineering and Construction Criteria Manual and the M HFD Urban Storm Drainage Criteria Manual. This project will provide both water quality and detention with the proposed on -site retention facility. This design will adequately protect public health, safety, and general welfare and have no adverse impacts on public rights - of -way or offsite properties. 5. REFERENCES Mile High Flood District Storm Drainage Criteria Manual (Volumes 1, 2, and 3), Revision dates vary Weld County Engineering and Construction Criteria Manual, March 2021 S. APPENDICES A. NRCS WEB SOIL SURVEY B. FEMA FLOOD MAP C. HYDROLOGIC COMPUTATIONS D. WATER QUALITY & RETENTION COMPUTATIONS E. DRAINAGE PLANS Westminster, Co 80031 720.774.7736 www. raptor-civi I.com Page 8 of 12 CIVIL ENGINEERING APPENDIX A: NRCS WEB SOIL SURVEY Westminster, Co 80031 720.774.7736 www. raptor-civi I.com USDA UStates a Department of Agriculture NKS Natural Resources Conservation Service A product of the National Cooperative Soil Survey, a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local participants Custom Soil Resource Report for Weld County, Colorado, Southern Part August 17, 2021 Preface Soil surveys contain information that affects land use planning in survey areas. They highlight soil limitations that affect various land uses and provide information about the properties of the soils in the survey areas. Soil surveys are designed for many different users, including farmers, ranchers, foresters, agronomists, urban planners, community officials, engineers, developers, builders, and home buyers. Also, conservationists, teachers, students, and specialists in recreation, waste disposal, and pollution control can use the surveys to help them understand, protect, or enhance the environment. Various land use regulations of Federal, State, and local governments may impose special restrictions on land use or land treatment. Soil surveys identify soil properties that are used in making various land use or land treatment decisions. The information is intended to help the land users identify and reduce the effects of soil limitations on various land uses. The landowner or user is responsible for identifying and complying with existing laws and regulations. Although soil survey information can be used for general farm, local, and wider area planning, onsite investigation is needed to supplement this information in some cases. Examples include soil quality assessments (http://www.nrcs.usda.goviwpsi portal/nres/main/soils/health/) and certain conservation and engineering applications. For more detailed information, contact your local USDA Service Center (https://offices.sc.egov.usda.govllocator/app?agency=arcs) or your NROS State Soil Scientist (http://www.nres.usda.govfwpslportal/nres/detaillsoils/contactusl? aid=nres 14.2 p2_053951). Great differences in soil properties can occur within short distances. Some soils are seasonally wet or subject to flooding. Some are too unstable to be used as a foundation for buildings or roads. Clayey or wet soils are poorly suited to use as septic tank absorption fields. A high water table makes a soil poorly suited to basements or underground installations. The National Cooperative Soil Survey is a joint effort of the United States Department of Agriculture and other f=ederal agencies, State agencies including the Agricultural Experiment Stations, and local agencies. The Natural Resources Conservation Service (N RCS) has leadership for the Federal part of the National Cooperative Soil Survey. Information about soils is updated periodically. Updated information is available through the N RCS Web Soil Survey, the site for official soil survey information. The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or a part of an individual's income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require 2 alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA's TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write to USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410 or call (800) 795-3272 (voice) or (202) 720-6382 (TDD). USDA is an equal opportunity provider and employer. 3 Contents Preface 2 How Soil Surveys Are Made 5 Soil Map 8 Soil Map 9 Legend 10 Map Unit Legend 11 Map Unit Descriptions 11 Weld County, Colorado, Southern Part 13 35—Loup-Boel loamy sands, 0 to 3 percent slopes 13 69—Valent sand, 0 to 3 percent slopes 14 70—Valent sand, 3 to 9 percent slopes 16 72 Vona loamy sand, 0 to 3 percent slopes 18 73 —Vona loamy sand, 3 to 5 percent slopes 19 References 22 4 How Soil Surveys Are Made Soil surveys are made to provide information about the soils and miscellaneous areas in a specific area. They include a description of the soils and miscellaneous areas and their location on the landscape and tables that show soil properties and limitations affecting various uses. Soil scientists observed the steepness, length, and shape of the slopes; the general pattern of drainage; the kinds of crops and native plants; and the kinds of bedrock. They observed and described many soil profiles. A soil profile is the sequence of natural layers, or horizons, in a soil. The profile extends from the surface down into the unconsolidated material in which the soil formed or from the surface down to bedrock. The unconsolidated material is devoid of roots and other living organisms and has not been changed by other biological activity. Currently, soils are mapped according to the boundaries of major land resource areas (MLRAs). MLRAs are geographically associated land resource units that share common characteristics related to physiography, geology, climate, water resources, soils, biological resources, and land uses (USDA, 2006). Soil survey areas typically consist of parts of one or more MLRA. The soils and miscellaneous areas in a survey area occur in an orderly pattern that is related to the geology, landforms, relief, climate, and natural vegetation of the area. Each kind of soil and miscellaneous area is associated with a particular kind of landform or with a segment of the landform. By observing the soils and miscellaneous areas in the survey area and relating their position to specific segments of the landform, a soil scientist develops a concept, or model, of how they were formed. Thus, during mapping, this model enables the soil scientist to predict with a considerable degree of accuracy the kind of soil or miscellaneous area at a specific location on the landscape. Commonly, individual soils on the landscape merge into one another as their characteristics gradually change. To construct an accurate soil map, however, soil scientists must determine the boundaries between the soils. They can observe only a limited number of soil profiles. Nevertheless, these observations, supplemented by an understanding of the soil -vegetation -landscape relationship, are sufficient to verify predictions of the kinds of soil in an area and to determine the boundaries. Soil scientists recorded the characteristics of the soil profiles that they studied. They noted soil color, texture, size and shape of soil aggregates, kind and amount of rock fragments, distribution of plant roots, reaction, and other features that enable them to identify soils. After describing the soils in the survey area and determining their properties, the soil scientists assigned the soils to taxonomic classes (units). Taxonomic classes are concepts. Each taxonomic class has a set of soil characteristics with precisely defined limits. The classes are used as a basis for comparison to classify soils systematically. Soil taxonomy, the system of taxonomic classification used in the United States, is based mainly on the kind and character of soil properties and the arrangement of horizons within the profile. After the soil 5 Custom Soil Resource Report scientists classified and named the soils in the survey area, they compared the individual soils with similar soils in the same taxonomic class in other areas so that they could confirm data and assemble additional data based on experience and research. The objective of soil mapping is not to delineate pure map unit components; the objective is to separate the landscape into landforms or landform segments that have similar use and management requirements. Each map unit is defined by a unique combination of soil components and/or miscellaneous areas in predictable proportions. Some components may be highly contrasting to the other components of the map unit. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The delineation of such landforms and landform segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, onsite investigation is needed to define and locate the soils and miscellaneous areas. Soil scientists make many field observations in the process of producing a soil map. The frequency of observation is dependent upon several factors, including scale of mapping, intensity of mapping, design of map units, complexity of the landscape, and experience of the soil scientist. Observations are made to test and refine the soil -landscape model and predictions and to verify the classification of the soils at specific locations. Once the soil -landscape model is refined, a significantly smaller number of measurements of individual soil properties are made and recorded. These measurements may include field measurements, such as those for color, depth to bedrock, and texture, and laboratory measurements, such as those for content of sand, silt, clay, salt, and other components. Properties of each soil typically vary from one point to another across the landscape. Observations for map unit components are aggregated to develop ranges of characteristics for the components. The aggregated values are presented. Direct measurements do not exist for every property presented for every map unit component. Values for some properties are estimated from combinations of other properties. While a soil survey is in progress, samples of some of the soils in the area generally are collected for laboratory analyses and for engineering tests. Soil scientists interpret the data from these analyses and tests as well as the field -observed characteristics and the soil properties to determine the expected behavior of the soils under different uses. Interpretations for all of the soils are field tested through observation of the soils in different uses and under different levels of management. Some interpretations are modified to fit local conditions, and some new interpretations are developed to meet local needs. Data are assembled from other sources, such as research information, production records, and field experience of specialists. For example, data on crop yields under defined levels of management are assembled from farm records and from field or plot experiments on the same kinds of soil. Predictions about soil behavior are based not only on soil properties but also on such variables as climate and biological activity. Soil conditions are predictable over long periods of time, but they are not predictable from year to year. For example, soil scientists can predict with a fairly high degree of accuracy that a given soil will have a high water table within certain depths in most years, but they cannot predict that a high water table will always be at a specific level in the soil on a specific date. After soil scientists located and identified the significant natural bodies of soil in the survey area, they drew the boundaries of these bodies on aerial photographs and 6 Custom Soil Resource Report identified each as a specific map unit. Aerial photographs show trees, buildings, fields, roads, and rivers, all of which help in locating boundaries accurately. Soil Map The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit. 8 40° 7 39" N 40° 7' 22" N 512160 512240 51 512400 Custom Soil Resource Report Soil Map 512480 512560 512^640 512720 512600 51 0 512960 r r T r T r lV r r - r .• _ L; s.° LS air Pa- JP! II •.• "I Soil Map may not be valid at thisscale. 512240 512320 512400 512480 512560 512640 51272) 512504 51 512160 Map Scale: 1:3,790 if printed on A landscape (11" x 8.5") sheet. Meters 0 50 10D 0 150 300 200 300 Feet 600 900 Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGSS4 9 512960 N N T a 40° 7 39" N 40° 7'22"N Custom Soil Resource Report MAP LEGEND Area of Interest (01) Area of Interest (AO!) Soils pabo • Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features a - Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide orSlip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways sozossis US Routes Major Roads Local Roads Backgr a nd Aerial Photography MAP INFORMATION The soil surveys that comprise your AO1 were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Weld County, Colorado, Southern Part Survey Area Data: Version 19, Jun 5, 2020 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Jul 19, 2018 Aug 10,2018 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. 10 Custom Soil Resource Report Map Unit Legend Map Unit Symbol Map Unit Name Acres in Aol Percent of Aol 35 Loup-Boel percent loamy slopes sands, 0 to 3 1.8 3.2% 69 Valent slopes sand, 0 to 3 percent 32.4 58.8% 70 Valent slopes send, 3 to 9 percent 4.7 8.6% 72 Vona loamy sand percent slopes 70 to 12.2 22.1% 73 Vona loamy sand, percent slopes 3 to 5 4.0 7.2% Totals for Area of Interest 55.0 100.0% Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit. A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits for the properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class. Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils. Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complex that it was impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape. Custom Soil Resource Report The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate pure taxonomic classes but rather to separate the landscape into landforms or landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however; onsite investigation is needed to define and locate the soils and miscellaneous areas. An identifying symbol precedes the map unit name in the map unit descriptions. Each description includes general facts about the unit and gives important soil properties and qualities. Soils that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement. Soils of one series can differ in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series. Some map units are made up of two or more major soils or miscellaneous areas. These map units are complexes, associations, or undifferentiated groups. A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps. The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha -Beta complex, 0 to 6 percent slopes, is an example. An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha -Beta association, 0 to 2 percent slopes, is an example. An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example. Some surveys include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example. 12 Custom Soil Resource Report Weld County, Colorado, Southern Part 35 _ Loup-Boel loamy sands, 0 to 3 percent slopes Map Unit Setting National map unit symbol: 362f Elevation: 4,550 to 4,750 feet Mean annual precipitation: 11 to 15 inches Mean annual air temperature: 46 to 52 degrees F Frost -free period: 130 to 180 days Farmland classification: Not prime farmland Map Unit Composition Loup and similar soils: 55 percent Boel and similar soils: 35 percent Minor components: 10 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Loup Setting Landform: &wales, drainageways, streams Down -slope shape.. Linear Across -slope shape: Linear Parent material: Sandy alluvium Typical profile H1 - 0 to 16 inches: loamy sand H2 - 16 to 40 inches: loamy sand H3 - 40 to 60 inches: sandy loam Properties and qualities Slope: 0 to 3 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water''Ksat) High (2.00 to 6.00 inlhr) Depth to water table: About 0 to 18 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content: 5 percent Available water supply, 0 to 60 inches: Low (about 5.2 inches) Interpretive groups Land capability classification ("irrigated): 4w Land capability classification 'nonirngated3: 6w Hydrologic Soil Group: AID Ecological site: R067BY029CO - Sandy Meadow Hydric soil rating: Yes Description of Boel Setting Landform: Swales, drainageways, streams Down -slope shape: Linear 13 Custom Soil Resource Report Across -slope shape: Linear Parent material: Stratified sandy alluvium Typical profile HI - 0 to 14 inches: loamy sand H2 - 14 to 60 inches: loamy sand Properties and qualities Slope: 0 to 3 percent Depth to restrictive feature: More than 80 inches Drainage class: Somewhat poorly drained Runoff class: Very low Capacity of the most limiting layer to transmit water ('Ksat): High to very high (5.95 to 19.98 inlhr) Depth to water table: About 18 to 36 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content: 5 percent Available water supply, 0 to 60 inches: Low (about 4.2 inches) Interpretive groups Land capability classification ('irrigated): 4w Land capability classification (nonirrigated): 6w Hydrologic Soil Group: A Ecological site: R067BY029CO !CO - Sandy Meadow Hydric soil rating: No Minor Components Osgood Percent of map unit: 5 percent Hydric soil rating: No Valent Percent of map unit: 5 percent Hydric soil rating: No 69—Valent sand, 0 to 3 percent slopes Map Unit Setting National map unit symbol: 2tczd Elevation: 3,000 to 51210 feet Mean annual precipitation: 13 to 20 inches Mean annual air temperature: 48 to 52 degrees F Frost -free period: 130 to 166 days Farmland classification: Farmland of local importance Map Unit Composition Valent and similar soils: 85 percent Minor components: 15 percent Custom Soil Resource Report Estimates are based on observations, descriptions, and transects of the mapunit. Description of Valent Setting Landforrn: Interdunes Landform position `two-dimensional): Footslope, toeslope Landform position (three-dimensional): Base slope Down -slope shape: Linear Across -slope shape: Linear Parent material: Noncalcareous eolian sands Typical profile A - O to 5 inches: sand AC - 5 to 12 inches: sand CI - 12 to 30 inches: sand C2 - 30 to 80 inches: sand Properties and qualities Slope: 0 to 3 percent Depth to restrictive feature: More than 80 inches Drainage class: Excessively drained Runoff class: Negligible Capacity of the most limiting layer to transmit water (sat): High to very high (6.00 to 39.96 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content: 1 percent Maximum salinity: Nonsaline (0.1 to 1.9 mmhoslcm) Available water supply, 0 to 60 inches: Very low (about 2.4 inches) Interpretive groups Land capability classification (irrigated): 4e Land capability classification (nonirricgated): 6e Hydrologic Soil Group: A Ecological site: R067BY015 O - Deep Sand, R072XA021 KS - Sands (North) (PE 16-20) Hydric soil rating: No Minor Components Julesburg Percent of map unit: 5 percent Landforrn: Interdunes Landform position (two-dimensional): Toeslope Landform position (three-dimensional): Base slope Down -slope shape: Linear Across -slope shape: Linear Ecological site: R067BY024CO - Sandy Plains, R072XA022KS - Sandy (North) Draft (April 2010) (PE 16-20) Hydric soil rating: No Dailey Percent of map unit: 5 percent Landform: Interdunes Landform position (two-dimensional): Toeslope 15 Custom Soil Resource Report Landform position (three-dimensional,): Base slope Down -slope shape: Linear Across -slope shape: Concave Ecological site: R067BY015CO - Deep Sand, R072 A022KS - Sandy (North) Draft (April 2010) (PE 16-20) Hydric soil rating: No Vona Percent of map unit: 5 percent Landform: Interdunes nes Landform position (two-dimensional): Toeslope LandformLandforrn position (three-dimensional): Base slope Down -slope shape: Linear Across -slope shape: Linear Ecological site: R067BY024CO 0 4CO - Sandy Plains, R07 A0 K - Sandy (North) Draft (April 2010) (PE 16-20) Hydric soil rating: No 70 Valent sand, 3 to 9 percent slopes Map Unit Setting National map unit symbol: 2tczf Elevation: 3,050 to 5,150 feet Mean annual precipitation: 12 to 18 inches Mean annual air temperature: 48 to 55 degrees F Frost -free period: 130 to 180 days Farmland classification: Not prime farmland Map Unit Composition \latent and similar soils: 80 percent Minor components: 20 percent Estimates are based on observations, descriptions, and transacts of the ma unit. Des c ri pti o n of Valent e nt Setting Landform: Hills, dunes Landform position (two-dimensional): Backslope, shoulder, footslope, summit Landform position (three-dimensional): Side slope, head slope, nose slope, crest Down -slope shape: Linear, convex Across -slope shape: Linear, convex Parent material: Noncalcareous eolian sands Typical profile A - 0 to 5 inches: sand Ac -5 to 12 inches: sand Cl - 12 to 30 inches: sand C2 _ 30 to 80 inches: sand Properties and qualities slope: 3 to 9 percent 16 Custom Soil Resource Report Depth to restrictive feature: More than 80 inches Drainage class: Excessively drained Runoff class: Very low Capacity of the most limiting layer to transmit water (Ksat): High to very high (6.00 to 39.96 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content: 1 percent Maximum salinity: Nonsaline (0.0 to 1.9 rn mhos/cm) Available water supply, 0 to 60 inches: Very low (about 2.4 inches) Interpretive groups Land capability classification (irrigated): 4e Land capability classification (nonirtigated): 6e Hydrologic Soil Group: A Ecological site: R0b7BY01 SCO - Deep Sand, R072XY109KS - Rolling Sands Hydric soil rating: No Minor Components Dailey Pie rcen t of map unit: 10 percent Landform: Interdunes Landform position (two-dimensional): Fero'slope, toeslope Landform position (three-dimensional): Base slope D o wn -slope shape: Linear Across -slope shape: Concave Ecological site: R067BY015CO - Deep Sand, 8072 A021 KS - Sands (North) (PE 16-20) Hydric soil rating: No Vona Percent of map unit: 5 percent Landform: Hills Landform position (two-dimensional): Footslope, backslope, shoulder Landform position (three-dimensional): Side slope, head slope, nose slope, base slope Down -slope shape: Linear Across -slope shape: Linear Ecological site: R067BY024CO - Sandy Plains, 8072 A022KS - Sandy (North) Draft (April 2010) (PE 16-20) Hydric soil rating: No Haxtun Percent of map unit: 5 percent Landform: Interdunes Landform position (two-dimensional): Footslope, toeslope Landform position (three-dimensional): Base slope Down -slope shape: Linear Across -slope shape: Concave Ecological site: R067BY024C0 - Sandy Plains, R072XY111KS - Sandy Plains Hydric soil rating: No Custom Soil Resource Report 72 Vona loamy sand, 0 to 3 percent slopes Map Unit Setting National map unit symbol: 363r Elevation: 4,600 to 5,200 feet Mean annual precipitation: 13 to 15 inches Mean annual air temperature: 48 to 55 degrees F Frost -free period: 130 to 160 days Farmland classification: Farmland of local importance Map Unit Composition Vona and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Vona Setting Landform: Plains, terraces Down -slope shape: Linear Across -slope shape: Linear Parent material: Alluvium and/or eolian deposits Typical profile Hi - 0 to 6 inches: loamy sand H2 - 6 to 28 inches: fine sandy loam H3 - 28 to 60 inches: sandy loam Properties and qualities Slope: 0 to 3 percent Depth to restrictive feature: More than 80 inches Drainage class: Well drained Runoff class: Very low capacity of the most limiting layer to transmit water (Ksat): High (1.98 to 6.00 inlhr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of pondin: None Calcium carbonate, maximum content: 15 percent Maximum salinity: Nonsaline to slightly saline (0.0 to 4.0 mmhos/cm) Available water supply, 0 to 60 inches: Moderate (about 6.5 inches) Interpretive groups Land capability classification (irrigated): 3e Land capability classification (nonirrigated): 4e Hydrologic Soil Group: Ecological site: 8067 BY02400 - Sandy Plains Hydric soil rating: No Custom Soil Resource Report Minor Components Remmit Percent of map unit: 10 percent Hydric soil rating: No Valent Percent of map unit: 5 percent Hydric soil rating: No 73 Vona loamy sand, 3 to 5 percent slopes Map Unit Setting National map unit symbol: 2x0j8 Elevation: 4,100 to 5,200 feet Mean annual precipitation: 12 to 17 inches Mean annual air temperature: 46 to 52 degrees F Frost -free period: 130 to 155 days Farmland classification: Not prime farmland Map Unit Composition Vona and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Vona Setting Landform: Hills, hillslopes Landform position `two-dimensional): Backslope Landform position (three-dimensional): Side slope Down -slope shape: Linear, convex Across -slope shape: Linear, convex Parent material: Eolian sands Typical profile Ai0 to 7 inches: loamy sand 8tl - 7 to 14 inches: sandy loam Bt2 - 14 to 20 inches: sandy loam Bk - 20 to 45 inches: sandy loam C - 45 to 80 inches: loamy sand Properties and qualities Slope: 3 to 5 percent Depth to restrictive feature: More than 80 inches Drainage class: Well drained Runoff class: Very low Capacity of the most limiting layer to transmit water (Ksat): High (2.00 to 6.00 in1fr) Depth to water table: More than 80 inches Custom Soil Resource Report Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content: 10 percent Maximum salinity: Nonsaline (0.1 to 1.0 mmhos/crn) Available water supply, 0 to 60 inches: Moderate (about 6.4 inches) Interpretive groups Land capability classification (irrigated): 3e Land capability classification (cnonirrigated): 45 Hydrologic Soil Group: A Ecological site: R057BYOI CO - Deep Sand Hydric soil rating: No Minor Components Ascalon Percent of map unit: 5 percent Landform: I nterfluves Landform position (three-dimensional): Interfluye Down -slope shape: Linear Across -slope shape: Linear Ecological site: R067BY024CO - Sandy Plains Hydric soil rating: No Kanter Percent of map unit: 5 percent Landform: Hills, interfluves Landform position (two-dimensional): Backslope Landform position (three-dimensional): Side slope, interfluve town -slope shape: Convex, linear Across -slope shape: Convex, linear Ecological site: R067BY024CO - Sandy Plains Hydric soil rating: No Olnest Percent of map will: 3 percent Landform: Interfluves, hills Landform position (two-dimensional): Footslope, toeslope Landform position (three-dimensional): Interfluve, base slope Down -slope shape: Linear, concave Across -slope shape: Linear, concave Ecological site: R067BY024CO - Sandy Plains Hydric soil rating: No Valent Percent of maunit: 2 percent Landform: Dunes Landform position (two-dimensional): Summit, shoulder, backslope Landform position (three-dimensional): Crest, side slope, nose slope Down -slope shape: Linear, convex Across -slope shape: Linear, convex Ecological site: 1 007SY015CO Deep Sand Hydric soil rating: No 20 Custom Soil Resource Report 21 References American Association of State Highway and Transportation Officials (AASHTO). 2004. Standard specifications for transportation materials and methods of sampling and testing. 24th edition. American Society for Testing and Materials (ASTM). 2005. Standard classification of soils for engineering purposes. ASTM Standard D2487-00. Cowardin, L.M., V. Carter, F.C. Golet, and E.T. LaRoe. 1979. Classification of wetlands and deep -water habitats of the United States. U.S. Fish and Wildlife Service FWS/OBS-79/31. Federal Register. July 13, 1994. Changes in hydric soils of the United States. Federal Register. September 18, 2002. Hydric soils of the United States. Hurt, G.W., and L.M. Vasilas, editors. Version 6.0, 2006. Field indicators of hydric soils in the United States. National Research Council. 1995. Wetlands: Characteristics and boundaries. Soil Survey Division Staff. 1993. Soil survey manual. Soil Conservation Service. U.S. Department of Agriculture Handbook 18. http://www.nrcs.usda.gov/wpsiportali nresldetaillnationallsoilst'acid=nres142p2_U 54262 Soil Survey Staff. 1999. Soil taxonomy: A basic system of soil classification for making and interpreting soil surveys. 2nd edition. Natural Resources Conservation Service, U.S. Department of Agriculture Handbook 436. http:// www.nres.usda.gov/wpsiportallnresldetail/national/soils/ ?cid=nres142p2_0 77 Soil Survey Staff. 2010. Keys to soil taxonomy. 11th edition. U.S. Department of Agriculture, Natural Resources Conservation Service. http:// www.nrcs.usda.goviwpsiportalinrcsidetailinationalisoilsncid=nrcs142p2 053580 Tiner, R.W., Jr. 1985. Wetlands of Delaware. U.S. Fish and Wildlife Service and Delaware Department of Natural Resources and Environmental Control, Wetlands Section. United States Army Corps of Engineers, Environmental Laboratory. 1987. Corps of Engineers wetlands delineation manual. Waterways Experiment Station Technical Report Y-87-1. United States Department of Agriculture, Natural Resources Conservation Service. National forestry manual. http://www.nrcs.usda.goviwpsiportalinrcsidetailisoilsi home/?cid=nresl 42p2_OS3374 United States Department of Agriculture, Natural Resources Conservation Service. National range and pasture handbook. http:IIwww.nres.usda.goviwpslportallnresl {detail/national/I and use/rang epasture/?cid=stelprdb104 0► 4 22 Custom Soil Resource Report United States Department of Agriculture, Natural Resources Conservation Service. National soil survey handbook, title 430 -VI. http://www.nres.usda.gov/wps/portal/ nres/detail/soilslscientists/?cid=nres14 'p _054242 United States Department of Agriculture, Natural Resources Conservation Service. 2006. Land resource regions and major land resource areas of the United States, the Caribbean, and the Pacific Basin. J.S. Department of Agriculture Handbook 296. http://www.nres.usda.gov/wpslportal/arcs/detail/nationallsoiIs!? cid =nres 142 p2_0 53624 United States Department of Agriculture, Soil Conservation Service. 1961. Land capability classification. U.S. Department of Agriculture Handbook 210. http:// www.nrcs.usda.gov/InternetiFSE D U M E NTS/n res 142p _052290. pd f 23 Page 9 of 12 CIVIL ENGINEERING APPENDIX B: FEMA FLOOD MAP Westminster, Co 80031 720.774.7736 www.raptor-eivilcom NOTES TO USERS LEGEND SPECIAL FLOOD HAZARD AREAS tS111As) SUBJECT TO This map is for use in administering the National Flood Insurance Program. It does not necessarily identify all areas subject to flooding, particularly from local drainage sources at small size. The community map repository should be consulted for possible. updated or additional flood hazard inforrialion. To obtain more detailed Information in areas where Base Flood Elevations (BEES) and/or floodways have been determined. users are encouraged to consul( the Flood Profiles and Floodway Data andlorSummary of Stillwater Elevations tables contained within the Flood Insurance Study (FIS) Report that accompanies this FIRM. Users should be aware that EFEs shown on the FIRM represent rounded whole -foot elevations. These 9FEs are intended for flood insurance rating purposes only and should not be used as the sae source of flood elevation information. Accordingly, flood elevation data presented in the FIS Report should be utilized in conjunction with Ule AIR IIA iU NUlpf.15 iQi Iul al.1 ie'Y Li1NIVr IIWU{Jiairr file rq}]CIIICIIt. Coastal Base Flood Elevations shown on this map apply only landward of 0.0' North Amerman Vertical alum of 1988 (NAND 68). Users of this FARM should be aware that coastal flood elevations are also provided In the Summary of Stillwater Elevations table it the Flood Insurance Study Report for this judsdiction. Elevations shown In the Summary of Stillwater Elevations table should be used for construction ardior flocdplain management purposes when they are higher than the elevations slicvn on this FIRM. Boundanes of the floodways were computed at cross sections and interpolated between cross sections. The floodways were based on hydraulic considerations •,with regard to requirements of the National Flood Insurance Program. Floodway widths and odder pertinent floodway data are provided in the Flood Insurance Study Report for this jurisdiction. Certain areas nut in Special Flout Hazard Areas may be pm -tetrad by flood control Structures. Refer to Seaton 2-d "Flood Protection Measures" of the Flood Insurance Study Report for information on flood control structures for this jurisdiction. -he projection used in the preparation of this map was Universal Transverse Mercator (UTM) zone 13. The horizontal datum was NAD 83, DRS 1980 spheroid. Differences in datum, spheroid, projection or UTM zones used in the production of FIRMs for adjacent jurisdictions may result in slight positional CI hferences in map features across Iunsdictlnn boundaries. These differences do not affect the accuracy of this FIRM. Flood elevations on this map are referenced to the North American Vertical Datum of 1988. These flood elevations must be compared to structure and ground elevations referenced to the same vertical datum. For information regarding conversion between the National Geodetic Vertical Datum of 1929 and the North American Vertical Datum of tt#I9, visit the National Geodetic Survey websits at httnJlvaww.ngs.noaa.gov or contact the National Geodetic Surrey at the following address. NGS Information Services NOAA, N;NGS12 National Geodetic Survey SSMC -3, 03202 1315 East-West Highway Silver Spring, Maryland 20910-3262 (301)713-3242 "9 obtain current elevation, description. and/or location Information for bench marks shown on this map, please contact the Information Services Branch of the National Geodetic Survey al (301) 713- 3242. or visit Its website at Jlt :ifwvwenos.noaaaov. Hasa map information shown on this FIRM was derived train NAIIPOrthapholography produced with a one meter ground resolution from photography dated 2013. -he profile baselines depleted on this map represent the hydraulic modeling baselines that match the flood profiles in the FIS report. As a result of improved topographic data, the profile baseine, in some cases, may deviate significantly from the channel centerline or appear outside the SFHA. -Ns map reflects more detailed aid up -to -dale stream channel configurations than those shown on the previous FIRM for this jurisdiction. The tloodplans and floodways that were transferred Porn the previous FIRM may have been adjusted to corifarm to these new stream channel configurations. As a result, the Flood Profiles and .Floodway Data tables for multiple slreanrs in the Flood nsurance Study Report (which contains authonlative hydraulic data) may inflect stream channel distances Thal differ from what is shown an this map. Corporate limits shown on this map are based on the best data available at the time of publication. Because changes due to annexations or tie -annexations may have occurred after this map was published, map users should contact appropriate community officials to verify current corporate limit locations_ Plentyrefer to the separately printed Map Index for an overview map of the aunty showing the layout of map panels: community map repository addresses: and a Listing of Communities table containing National Flood Insurance Program dales for each community as well as a isling of the panels on which each community is located. For information on available products associated with this FIRM vial the Map Service Center (MSC) websile al hflw/mac.femartov Available products may include previously issued Letters of Map Change, a Flood Insurance Study Report, afWLJf digital versiohe of this I11ap. Many Of Viggo PILJCIUCI'S WO be ordered CI obtained directly from the MSC websile. I you have questions about this map, how to order products, or the National Flood Insurance Program in general. please call the FEMA Map Information exchange (FMIX) at 1.6T7•FEMA-MAP (1-877-336.2627) or visit the FEMA webske at http:rivevw..fema.sbov/businesstnit, 1U4:. S.2, au - 40° 07 or 144 f MIrrN L144tm,IN e.4 CO J W O u'r;� i�L ill 5?il�L �vT�ifd 4437)COn r,l ddsrnac, h u3CCUmpj -01NS PANEL 4D' or 4e., 104° 52' 30 lied! Mich /NO Oitcl, 'igrr.' ,E r r • Weld ('ollnty .. ▪ l nincorporated'kreas nxnzt 6 Weld Gountt Unincorporated aere4 4.1S0266 JOINS PANEL 1915 JOINS PANEL 211E. s- noco FT 31fi;cc0 FT NOTE MAP AREA SHOWN ON THIS PANEL IS LOCATED WITHIN RANGE 57 WEST. 104° 48' 45" 40' 07' 30" SUBJECT PROPERTY THIS AREA SHOWN ATA SCALE OF 1" = 500' ON MAP NUMBER 08123G2 g 1 02 THIS AREA SHOWN ATA SCALE OF 1" = 500' ON MAP NUMBER 08123O2104 JOINS PANEL 2110 3190000 FT 1285000 FT 1 LIJUIuIv Cl 127001''0 FT 40° 08'45" 104" 48' 45m 111111AIn eTTM1M DV TUC IOR M1h1AII IAI runlet. gimme. II1LI IIdl1I W11 WI I I IL JIM Pll %UM= LI IRIt..4 ILA/VINO The 1% annual chance flood 0.09 -year flood). also known as the tote nwd, is the rlcd That has a 1134 chance of being egcakd or exceeded in any siren year. The Spec al Flood Httardl Area is the area sutgex to 9apdrg by trig 1% awee1 crancetiovc. Areas of Steger Road Hazard include Zug A. AE, AH, AO, AR, 999, V and vE. The Ease Flood Elevation is the orate-srorace elevation 5` the 1% annual chance flood, ZONE A ZONE AE NoBase Rood Elevations determined EaFIbtel Erevainns rfelermined. ZONE AH FFond depths of Ira 3 fed (usually areas of palling); Base FIRM ElevaMbns determined. ZONE AO Flood depths of 1 10 .3feet (usually theeIowan slop ri1 terrain); average depths determined. For areas of alluvial fan flooding, witches a ;a determined. ZONE AR ZONE A99 ZONE V ZONE. vE Speaa! Flood razed altos formerly pnxected from the i% anrual chance flood by a hood cordial system Nat was subsequently decedited. Zone ARlac i`atc• Ina( Ur ,pony,, Strad wnbol Srytenn iS being rvslvru11V prpvid' pratectcn on the 1% annual dance cr greatertklod. mem r0 be gued d from 195 annual Chance }Iced by a Federal Mace protegic n system under construction; no Base Flood Elevating determined. Coastal -kW Yore with velccrty 'wand (waive ectlpn); re Ra`e Flccc Meveton5 e errneec.. Coastal rl]cd Axle with velocity hazard (wave action); Bose Rood enriaa rls 4102ernli-ed. FLOODWAY AREAS IN ZONE AE The fioodway is the chard of a stream pia any acjacan flooielatn areas that must be Icy free of enacted -molt so that the 1%annual clam:e faod can to carted wi[Ircvt substantial Fracases in Pacd wiggles, ►.': •' •1 ZONE )C ZONE ZONE, D OTHER. El ODI} AREAS Agge5. C.2S4 annvel chance food; ar6dS of 1% err uel charre flood with average depta of less than 11tat or with drainage areas lets than 1 square mite; and area.; protegee by levees Iran 1% animal dance tlrwd, OTHER AREAS Areas dermined to be outs de the 9.2% arnuaI chance M17odplaln ANEW, in wind' Food h,Im 11s arc uldl3vmined, but zuset 4e.. COASTAL BARRIER RESOURCES SYSTEM (CBRS) AREAS OTHERWISE PROTECTED AREAS (OPA5) CRS areas and OPAM are corm* located *thin or adjacent to Spacial Real Hazard Areas. 1% Annual! fLance HIX:dpisin trounealy (FL 987;) 3.2% Atha' Chyme FNcdptairl Boundary Floodway hnurc ary Zone G bnundary c8RSantl OPA bouncay Boundary dvldIns Special flca; I Ware Zoos and baunday 1Niffing Sprain Find I-bl2rd Ate& c' iMrr-ent ease Hoed Be'aat%' n! flood depths, dept} s, or rood veiocides. Ease Flood Elevation ire and value: Seaton n feet' Ease Flood Elevation value where unsarm wittah zone; eletaden rn ream tFdenrrF111rIeM Nt3rth Anwr4an veto. art's' 1% Cosseerticn urge 'transact line Geographic coorcinates'aneroid to the North America, Delano( 1893 (NAP E3) %Vegan Ftemisphere 5949 -foot tltas: Caloiada State Plane Central zone FFIPSzo ne 902). umbe-[anfarmal Conic protection 1900 -roarer Universal 'Transverse Etrcaborgnd oaths, ZOne 13 Perch mart see elrpyrlatcn in Ntil to U5e15 Section of th 5 FIRM parrpl} • 411.5 River Mlle MAP REPOSITORIES Rater lo Map Rapes tortes lislor Map Index 45" 02' CS". 93" 9Z' 1Z' 3100099 FT +log ua„ N DRE510 x EFFECTIVE CASTE OF GCUNTY'IMDE FLOOD INSURANCE RATE star Jan Lamy20201! E=FECTINE PATEt5) OF R EV15! ONa5h TO THIS PANEL tar eemmv,nay map ramaian higtOry pica- to=anlya t msppinp, near Rains gammoniy Map Elstorytable Ie- tedIntheFlood''.murineStudyreportfarwrhju11dnlen. To de:ermine if flood insurance is available in Ihs mriri1i lit', conact your insuranceapes er tail re Nat onall Flood insurance Froare m at 1-eOo-a3afi82a. MAP SCALE r = 1000' 509 4 1000 7009 � IFE€T METERS 300 0 3x0 00 I@ I in real PANEL 2145E FIRM FLOOD INSURANCE RATE MAP WELD COUNTY, COLORADO AND INCORPORATED AREAS PANEL 2105 OF 2250 (SEE MAP INDEX FOR FIRM PANEL LAYOUT) CONTAINS• COMMUNITY WilfiLp CC.:N Pt NUMBER PANEL SUFFIX cattier sloe E No -lice toUser The Map Number shown below should be used when placing map orders; the Community Number shown above should be used on insurance applications for the subject community. MAP NUMBER 08123C2105E EFFECTIVE DATE JANUARY 20, 2016 tiiiei'y,+cuiy maatrakeateatage ucy I rrueral Page 10 of 12 CIVIL ENGINEERING APPENDIX C: HYDROLOGIC COMPUTATIONS Westminster, Co 80031 720.774.7736 www.raptor-eivilcom liI V I0I1yY I ]-mil r u\ r' L.41 PPr] i PROJECT NAME: 8711 CR 23 CALCULATED BY: ENE DATE: 3/10/2022 "I" Factors for Percent Imperviousness NI:ovili Walk/D -, _avel Landscape I (96) 90% 90% 40% 2% CIVIL ENGINEERING Runoff Coefficients derived from Weld County "Rational Method Runoff Coeffkients, C -values" for type A soils Riiticii ID Area a - -1 (a • Basin Area (sf) ��- si���'ei �- 4�rr.. GL�ur, ' Waif/Drive res Gravel y4y.m a (sf) � I -ndscape rea {sf} Impersness Composite Hi 6.98 304162 0 0 0 304162 2.00% Dl 6.98 304162 5593 0 19388 279181 6.04% CALCULATION OF A PEAK RUNOFF USING RATIONAL METHOD Project Title: Catchment ID: 8711 COUNTY ROAD 23 10 -YEAR HISTORIC I. Catchment Hydrologic Data Catchment ID = Area = Percent Imperviousness = NRCS Soil Type = H1 6.98 2.00 A II. Rainfall Information Design Storm Return Period, Tr = C1 = C2= C3= P1= Acres ° o A, B, C, or D I (inchlhr) = Cl * P1 /(C2 + Td)^C3 10 28.50 10.00 0.786 1.61 years (input return period for design storm) (input the value of Cl) (input the value of C2) (input the value of C3) inches (input one -hr precipitation --see Sheet "Design Info") III. Analysis of Flow Time (Time of Concentration) for a Catchment Runoff Coefficient, C = Overide Runoff Coefficient, C = 5-yr. Runoff Coefficient, C-5 = Overide 5-yr. Runoff Coefficient, C = 0.07 0.00 (enter an overide C value if desired, or leave blank to accept calculated C.) (enter an overide C-5 value if desired, or leave blank to accept calculated C-5.) Illustration LEGEND C Big Flow Direction Catchment Boundary NRCS Land Type Conveyance Heavy Meadow 2.5 Tillage/ Field 5 Short Pasture/ Lawns 7 Nearly Bare Ground 10 Grassed Swales! Waterways 15 Paved Areas & Shallow Paved Swales (Sheet Flow) 20 Calculations: Reach ID Overland Slope S ft/ft input Length L ft input 5-yr Runoff Coeff C-5 output NRCS Convey- ance input Flow Velocity V fps output Flow Time Tf minutes output 0.0300 500 0.00 N/A 0.27 30.90 1 0.0300 116 2 3 4 5 Sum 616 IV. Peak Runoff Prediction Rainfall Intensity at Computed Tc, I = Rainfall Intensity at Regional Tc, I = Rainfall Intensity at User -Defined Tc, I = 2.46 3.85 3.77 inchlhr inch/hr inchlhr 20.00 3.46 0.56 Computed Tc = Regional Tc = User -Entered Tc = Peak Flowrate, Op = Peak Flowrate, Op = Peak Flowrate, Op = 31.46 13.42 14.00 1.19 1.86 1.83 cfs cfs cfs ud-rational-v1.02a (10-YR HISTORIC), Tc and PeakO 3/10/2022, 1:23 PM CALCULATION OF A PEAK RUNOFF USING RATIONAL METHOD Project Title: Catchment ID: 8711 COUNTY ROAD 23 10 -YEAR DEVELOPED I. Catchment Hydrologic Data Catchment ID = Area = Percent Imperviousness = NRCS Soil Type = D1 6.93 6.04 A II. Rainfall Information Design Storm Return Period, Tr = Cl C2= C3= P1= Acres 0/0 A, B, C, or D I (inch/hr) = Cl * P°I /(C2 + Td}^C3 10 23.50 10.00 0/86 1.61 years inches (input return period for design storm) (input the value of C1) (input the value of C2) (input the value of C3) (input one -hr precipitation --see Sheet "Design Info") III. Analysis of Flow Time (Time of Concentration) for a Catch ment Runoff Coefficient, C = Overide Runoff Coefficient, C = 5-yr. Runoff Coefficient, C-5 = Overide 5-yr. Runoff Coefficient, C = 0.11 0.03 (enter an overide C value if desired, or leave blank to accept calculated C.) (enter an overide C-5 value if desired, or leave blank to accept calculated C-5.) Illustration overland Reach 1 flew MRCS Land Type Conveyance Heavy Meadow 2.5 Tillage/ Field 5 Short Pasture/ Lawns 7 Nearly Bare Ground 10 Grassed Swalesf Waterways 15 Paved Areas & Shallow Paved Swales (Sheet Flow) 20 Calculations: Reach ID Overland Slope S ft/ft input Length L ft input 5-yr Runoff Coeff C-5 output N RCS Convey- ance input Flow Velocity V fps output Flow Time Tf minutes output 0.0300 ' 500 0.03 N/A 0.23 30.10 1 0.0300 116 2 3 4 5 Sum 616 IV. Peak Runoff Prediction Rainfall Intensity at Computed To, I = Rainfall Intensity at Regional Tc, I linfall Intensity at User -Defined To, I = 2A9 3.85 3.77 inchih r inchlh r inchlh r 20.00 3.46 0.56 Computed Tc = Regional Tc = User -Entered Tc Peak Flowrate, Op = Peak Flowrate, Op = Peak Flowrate, Op = 30.66 13A2 14.00 1.33 2.32 2/7 cfs cfs cis ud-rational-v1.02a (10-YR DEVELOPED), To and PeakO 3/10/2022, 1:22 PM CALCULATION OF A PEAK RUNOFF USING RATIONAL METHOD Project Title: Catchment ID: 8711 COUNTY ROAD 23 100-YR DEVELOPED I. Catchment Hydrologic Data Catchment ID = Area = Percent Imperviousness = NRCS Soil Type = D1 6.93 6.04 A II. Rainfall Information Design Storm Return Period, Tr = Cl C2= C3= P1= Acres 0/0 A, B, C, or D I (inch/hr) = Ct * P1 /(C2 + Td}^C3 100 23.50 10.00 0/86 2.63 years inches (input return period for design storm) (input the value of C1) (input the value of C2) (input the value of C3) (input one -hr precipitation --see Sheet "Design Info") III. Analysis of Flow Time (Time of Concentration) for a Catch ment Runoff Coefficient, C = Overide Runoff Coefficient, C = 5-yr. Runoff Coefficient, C-5 = Overide 5-yr. Runoff Coefficient, C = 0.25 0.03 (enter an overide C value if desired, or leave blank to accept calculated C.) (enter an overide C-5 value if desired, or leave blank to accept calculated C-5.) Illustration overland Reach 1 flew NRCS Land Type Conveyance Heavy Meadow 2.5 Tillage/ Field 5 Short Pasture/ Lawns 7 Nearly Bare Ground 10 Grassed Swales/ Waterways 15 Paved Areas & Shallow Paved Swales (Sheet Flow) 20 Calculations: Reach ID Overland Slope S ft/ft input Length L ft input 5-yr Runoff Coeff C-5 output NRCS Convey- ance input Flow Velocity V fps output Flow Time Tf minutes output 0.0300 ' 500 0.03 N/A 0.23 30.10 1 0.0300 116 2 3 4 5 Sum 616 IV. Peak Runoff Prediction Rainfall Intensity at Computed Tc, I = Rainfall Intensity at Regional Tc, I infall Intensity at User -Defined To, I = 4.15 6A0 6.23 inchih r inchih r inchlhr 20.00 3.46 0.56 Computed Tc = Regional Tc = User -Entered Tc Peak Flowrate, Op = Peak Flowrate, Op = Peak Flowrate, Op = 30.66 13A2 14.00 7.20 11.11 10.90 cfs cfs cfs ud-rational-v1.02a (100-YR DEVELOPED), Tc and PeakO 3/10/2022, 1:23 PM 11/16/21, 4:26 PM Precipitation Frequency Data Server NOAA Atlas 14, Volume 8, Version 2 Location name: Fort Lupton, Colorado, USA* Latitude: 40.1242°, Longitude: -104.8535° Elevation: 4933.71 ft's" * source: ESRI Maps ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES Sanja Redcap Deborah Martin, Sandra Pavlovic, Ishani Roy, Michael St. Laurent, Carl Trypaluk, Dale Unruh, Michael Yekta, Geoffery Bonnin NOAA, National Weather Service, Silver Spring, Maryland PF tabular PF graphical I Maps & aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Average recurrence interval (years) Duration I I 2 I 5 1 10 ii 25 [so 100 200 500 1000 5 -min I 0.231 (0.179-0.299) I 0.281 (0.218-0.364) I 0.378 1 (0.292-0.491) 0.473 (0.363-0.617) 0.624 (0.473-0.870) 0.758 (0.557-1.06) 0.906 (0.643-1.30) 1.07 (0.729-1.58) 1.31 (0.859-1.98) 1.51 (0.957-2.29) 10 -min 0.339 (0.262-0.43€) 0.412 (0.319-0.533) 0.554 (0.427-0.719) 0.693 (0.531-0.903) 0.914 (0.693-1.27) 1.11 (0.815-1.56) 1.33 (0.941-1.90) 1.57 (1.07-2.31) 1.92 (1.26-2.90) 2.22 (1.40-3.35) 15 -min 0.413 (0.320-0.53) 0.503 (0.389-0.650) 0.675 (0.521-0.877) 0.845 (0.648-1.10) 1.12 (0.845-1.55) 1.35 I (0.994-1.90) 1.62 (1.15-2.32) 1.91 (1.30-2.81) 2.34 (1.53-3.54) 2.70 (1.71-4.08) 304nin 0.561 (0.434-0.725) 0.679 (0.525-0.878) 0.909 (0.701-1.18) 1.14 (0.871-1.48) 1.50 (1.14-2.09) 1.82 (1.34-2.55) 2.18 (1.55-3.13) 2.58 (1.76-3.79L 3.16 (2.07-4.77) 3.65 (2.31-5.51) 60 -min 0.685 (0.530-0.886) 0.827 (0.640-1.07) 1.11 (0.854-1.44) 1.39 (1.06-1.81) 1.84 (1.39-2.57) 2.24 (1.65-3.14) 2.68 (1.91-3.85) 3.18 (2.17-4.69) 3.92 (2.57-5.92) 4.53 (2.87-6.85) 2 -hr 0.809 (0.633-1.03) 0.975 (0.762-1.25) 1.31 (1.02-1.67) 1.64 (1.27-2.11) 2.17 (1.67-3.00) 2.65 (1.97-3.68) 3.19 (2.29-4.52) 3.79 (2.61-5.51) 4.67 (3.09-6.96) 5.41 (3.46-8.06) 3 -hr 0.878 I (0.691-1.11) 1.05 (0.829-1.34) 1.41 (1.10-1.79) 1.76 (1.37-2.25) 1 2.33 (1.80-3.20) 2.85 (2.13-3.93) 3.43 (2.48-4.83) I 4.07 1 (2.83-5.88) 5.03 (3.35-7.44) 5.83 p.75 -8.61)6 -hr 1.04 (0.826-1.30) 1.23 (0.978-1.55) I 1.61 (1.28-2.03) 2.00 (1.58-2.53) 2.512 (2.05-3.55) 3.18 (2.41-4.33) 3.81 (2.78-5.29) 4.51 (3.16-6.42) 5.55 (3.74-8.09) II 6.41 (4.17-9.35) 12 -hr 1.27 x(1.02-1.57) 1.49 (1.19-1.84) 1.91 (1.53-2.37) 2.32 (1..85-2.90) 2.98 (2.34-3.95) 3.56 (2.71-4.75) 4.20 (3.09-5.7`3) 4.91 (3.48-6.88) 5.96 (4.05-8.54) 6.83 (4.49-9.81) 24 -hr 1.51 (1.23-1.84) 1.79 (1.45-2.19) 2.29 (1.85-2.81) 2.75 (2.21-3.39) 3.45 (2.72-4.47) 4.05 (3.11-5.29) 5.39 (3.84-7.39) 6.38 (4.37-8.97) 7.19 (4.78-10.2) 2-day1.71 (1.41-2.07) 2.08 (1.71-2.52) 2.71 (2.22-3.28) 3.24 (2.64-3.95) 1 4.01 (3.17-5.07) 4.63 (3.57-5.92) 5.26 (3.93-6.89) 5.93 (4.25-7.96) 6.84 (4.72-9.43) 7.55 (5.08-10.5) 3 -dad 1.87 (1.55-2.24) 2.25 (1.86-2.70) 2.88 (2.38-3.47) 3.43 (2.81-4.15) 4.21 (3.35-5.28) 4.83 (3.75-6.13) 548 (4.11-7.11) 6.15 (4.44-8.18) 7.06 (4.91-9.65) 7.78 (5.27-10.8) 4 -day 2.00 (1.66-2.39) 2.37 (1.97-2.84) 3.55 (2.92-4.27) 4.34 (3.46-5.41 } 4.96 5.61 (4.24-7.24) 6.29 (4.56-8.32) 7.22 (5.05-9.80) 7.95 (5.41-10.9) 7 -day 2.29 (1.92-2.71) 2.68 (2.25-3.18) 3.34 (2.79-3.97) 3.91 (3.24-4.65) 4.71 (3.80-5.80) 5.35 (4.21-6.67) 6.01 (4.58-7.66) 6.69 (4.90-8.74) 7.63 (5.38-10.2) 8.36 (5.74-11.3) 10 -day 2.54 (2.15-2.99) I 2.96 (2.49-3.48) 3.65 (3.06-4.30) 4.23 (3.54-5.01) 5.06 (4.10-6.17) 5.71 (4.52-7'.05) 6.37 (4.88-8.05) I 7.06 (5.20-9.15) 7.998.71 (5.66-10.6) 3.25 (2.78-3.77) 3.73 (3.18-4.33) ) 4.51 ((3.83-5.24) 5.16 (4.36-6.02) 6.06 4.95-7.26 ( ) 6.75 (5.40-8.20) 7.45 (5.77-9.25) 8.16 (6.07-10.4) 9.11 (6.52-11.9)1 9.82 (6.87-13.U) 30 -day 3.81 (3.28-4.39) 4.36 (3.74-5.02) 5.24 (4.48-6.04) 5.96 (5.07-6.90) 6.95 (5.71-8.24) 7.70 (6.19-9.26) 8.45 (6.57-10.4) 9.20 (6.88-11.6) 10.2 (7.33-13.1) 10.9 (7.68-14.3) _ 45-da 4.49 (ll 3.88-5.13) ! 5.14 (4.44-5.87) 6.18 Y (5.32-7.07) 7.02 (6.01-8.07) 8.15 (6.73-9.58) 9.00 (7.28-10.7) 9.83 (7'.70-12.0) 10.6 (8.01-13.3) 11.7 (8.4$-15.0) 12.5 (8.84-16.2 60 -day 5.04 (4.38-5.72) 5.79 (5.03-6.58) 6.99 (6.05-7'.97) 7.96 (6.84-9.10) 9.23 (7.66-10.8) 10.2 (8.27-12.0) 11.1 (8.72-13.4) 12.0 (9.06-14.8) 13.1 (9.55-16.6) 13.9 (9.92-18.0) 1 Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. Please refer to NOAA Atlas 14 document for more information. Back to Top PF graphical https://hdsc.nws.noaa.govlhdsclpfds/pfds_printpage.html `lat=40.1242&Ion=-104.8535&data=depth&units=english&series=pds 1/4 11/16/21, 4:26 PM Precipitation Frequency Data Server 14 12. ,E 10 C O 0 0 PD'S-based depth -duration -frequency (DDF) curves Latitude: 40.124R° , Longitude: -104..8535° C L. 5 10 25 50 100 200 NOAA Atlas 14, Volume 8, Version 2 C L. n rid rrli I I N 0 JJ r-1 Duration rN IT; m-. � 11; 11; et IL.) IL.) L1 I ice! rn rr Average recurrence interval (years) Itm 13 13 1 t1 13 I I I I 0 0 LJ } 500 1000 Created (GMT}: The Nov 16 2.3:26:42 2D21 Back to Top Maps & aerials Small scale terrain Average recurrence interval (years) 1 10 25 50 100 200 500 1 000 Duration 5 -nn — 2 -day 10--mh — 3 -day 1 S-fnln 4 d a 30 -min - 7- i ay 60-mn 10 -clay 2-r r — 20 -dad 3 -hr — 3O -day 6-11r 45 -day 12 -hr — 6O -day 24 -hr https://hdsc.nws.noaa.govlhdsclpfds/pfds_printpage.html `Iat=40.1242&Ion=-104.8535&data=depth&units=english&series=pds 2/4 11/16/21, 4:26 PM Precipitation Frequency Data Server anQ 110 Large scale terrain Fr.rtCollins Long, Peak 4345iri Lelaim cnt Boulder •} I �° I • I •Dergver 1 rf r mo. .r sf_a"Pia I:4 4 c. 100km 1 6Omi it N Large scale map Large scale aerial Clue erine Fort':olline Grefeler Lanl niont • Sould IL - Denyer 1- 100km i fi0mi https://hdso.nws.noaa.goer/hdso/pfds/pfds_printpage.html `lat=40.1242&Ion=-104.8535&data=depth&units=english&series=pds 3/4 11/16/21, 4:26 PM Precipitation Frequency Data Server Back to RV US Department of Commerce National Oceanic and Atmospheric Administration National Weather Service National Water Center 1325 East West Highway Silver Spring, MD 20910 Questions?: HDSC.Questions@noaa.gov Disclaimer https://hdsc.nws.noaa.govlhdsclpfds/pfds_printpage.html `Iat=40.I242&Ion=-104.8535&data=depth&units=english&series=pds 4/4 Page 11 of 12 CIVIL ENGINEERING APPENDIX D: WATER QUALITY & RETENTION COMPUTATIONS Westminster, Co 80031 720.774.7736 www. raptor-eivi Isom DETENTION VOLUME BY THE MODIFIED FAA METHOD Project: Project: 8711 COUNTY ROAD 23 Basin ID: RETENTION POND SIZING (For catchments less than 160 acres only. For larger catchments, use hydrogra ph routing method) (NOTE: for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) Determination of MINOR Detention Volume Using Modified FAA Method Determination of MAJOR Detention Volume Using Modified FAA Method Design Information (Input): Design Information (Input): Catchment Drainage Imperviousness I;, = 6.04 percent Catchment Drainage Imperviousness L = 6.04 percent Catchment Drsinage Area A = 6.980 acres Catchment Drainage Area A = 6.980 acres Predevelopment NRCS Soil Group Type = A A. B. C. or 0 Predevelopment NRCS Soil Group Type = A A, B, C, or 0 Return Period for Detention Control T = 14 years (2, 5, 14, 25. 54, or 104) Return Period for Detention Control T = 100 years (2, 5, 10. 25. 54, or 100) Time of Concentration of Watershed Tc = 31 minutes Time of Concentration of Watershed Tc = 31 minutes Allowable Unit Release Rate q = 0.01 cfslacre Allowable Unit Release Rate q = 0.04 cfslacre One -hour Precipitation P1 = 1.39 inches One -hour Preci pi Cation P1 = 2.68 inches Design Rainfall IDF Formula I = C1" P11(C2+TjtC3 Design Rainfall IDF Formula I = C1" P11(C2+TcjaCg Coefficient One C1 = 28.50 Coefficient One C1 = 28.50 Coefficient Two C2 = 10 Coefficient Two 02 = 10 Coefficient Three G, = 4.789 Coefficient Three 0,789 Determination of Average Outflow from the Basin (Calculated): Determination of Average Outflow from the Basin (Calculated): Runoff Coefficient C = 0.11 Runoff Coefficient C = 0.25 InflowPeak Runoff Qp-in = 1.62 cfs Inflow Peak Runoff Qp-in = 7.12 cfs Allowable Peak Outflow Rate Qp-out = 0.03 cfs Allowable Peak Outflow Rate Qp-out = 0.03 cfs Mod. FAA Minor Storage Volume = 6,880 cubic feet Mod. FAA Major Storage Volume = 35,663 cubic feet Mod. FAA Minor Storage Volume = 0.158 acre -ft Mod. FAA Major Storage Volume = 0.819 acre -ft 24 <- Enter Rainfall Duration Incremental Increase Value Here (e.g. 5 for 5 -Minutes) Rainfall Duration minutes (input) Rainfall Intensity inches; hr (output) Inflow Volume acne -feet (output) Acjustment Factor "m" (output) Average Outflow cfs (output) Outflow Volume acre-feet (output) Storage Volume acre-feet (output) Rainfall Duration minutes (input) Rainfall Intensity inches 1 hr (output) Inflow Volume acre-feet (output) Adjustment Factor "m" (output) Average Outflow cfs (output) Outflow Volume acre-feet (output) Storage Volume acre-feet (output) 0 0.00 0.000 0.00 0.00 0.004 0.000 0 0.00 4.000 0.00 0.04 0.004 0.000 24 4.73 0.273 1.00 0.03 0.001 0.272 24 2.45 0.062 1.00 0.03 0.001 0.061 48 1.61 0.082 4.82 0.03 0.002 0.080 48 3.10 0.358 0.82 0.02 0.002 0.356 72 1.22 0.093 4.72 0.02 4.002 0.491 72 2.36 0.448 0.72 0.02 0.002 0.447 96 1.93 4.445 0.66 0.02 0.402 0.442 96 1.00 0.142 0.66 0.42 4.403 0.498 120 0.85 0.108 4.63 0.42 0.404 0.104 120 1.64 4.473 0.63 0.02 0.403 0.470 144 1.44 0.497 0.61 0.02 0.003 0.494 144 0.74 0113 4.61 0.02 0.004 0.109 168 0.66 0.118 4.59 0.02 0.005 0.113 168 1.28 0.517 0.59 0.02 0.004 0.513 192 0.60 0.122 4.58 0.02 0.005 0.117 192 1.16 0.535 0.58 0.02 0.004 0.531 216 0.55 0.128 4.57 0.02 0.406 0.120 216 1.06 0.551 0.57 0.02 0.005 0.546 240 0.51 0.129 4.56 0.02 0.007 0.122 240 0.98 4.565 0.56 0.02 0.005 0.560 264 0.47 0132 4.56 0.02 0.007 0.125 264 0.91 4.578 0.56 0.02 0.006 0.572 288 0.85 0.590 0.55 0.02 0.006 0.584 288 0.44 0.135 4.55 0.02 0.008 0.127 312 0.80 0.642 0.55 0.02 0.007 0.595 312 0.42 0.137 4.55 0.02 0.008 0.129 336 0.39 0140 4.55 0.02 0.009 0.131 336 0.76 0.612 0.55 0.02 0.007 0.605 360 0.37 0142 4.54 0.42 0.009 0.133 360 0.72 0.622 0.54 0.02 0.008 0.615 384 0.68 0.631 0.54 0.02 0.008 0.623 384 0.35 0.144 4.54 0.42 0.014 0.134 408 0.34 0.146 4.54 0.42 0.411 0.136 408 0.65 0.640 0.54 0.02 0.008 0.632 432 0.32 0.148 4.54 0.02 0.411 0.137 432 0.62 0.649 0.54 0.01 0.009 0.640 456 0.31 0.150 4.53 0.02 0.012 0.138 456 0.60 0.657 0.53 0.01 0.009 0.647 480 0.30 0.152 4.53 0.02 0.412 0.139 480 0.58 4.665 0.53 0.01 0.014 0.655 504 0.29 0.153 4.53 0.02 0.413 0.140 504 0.55 4.672 0.53 0.01 0.414 0.662 528 0,28 0.155 4.53 0.02 0.413 0.142 528 0.54 0.679 0.53 0.01 0.011 0.668 652 0.27 0.157 4.53 0.02 0.414 0.143 552 0.52 4.686 0.53 0.01 0.011 0.675 576 0.50 4.692 0.53 0.01 0.412 0.681 576 0.26 015$ 4.53 0.02 0.415 0.143 600 0.25 0.159 4.53 0.02 0,015 0.144 600 0.48 0.699 0.53 0.01 0.012 0.687 624 0.24 0.161 4.52 0.02 0,016 0.145 624 0.47 0.705 0.52 0.01 0.013 0.692 648 0<46 0.711 0.52 0.01 0.413 0.698 648 0.24 0.162 4.52 0.02 0.416 0.146 672 4.23 0.164 4.52 0.02 0.417 0.147 672 4.44 0.717 0.52 0.01 0.414 0.743 696 0.22 0.165 4.52 0.42 0.417 0.147 696 4.43 0.722 0.52 0.01 0.014 0.708 720 4.42 0.728 0.52 0.01 0.014 0.713 720 0.22 0.166 4.52 0.02 0.018 0.148 744 0.21 0.167 4.52 0.02 0.419 0.149 744 4.41 0.733 0.52 0.01 0.415 0.718 768 0.21 0.168 4.52 0.02 0.419 0.149 768 4.40 0.738 0.52 0.01 0.015 0.723 792 0.20 0.170 4.52 0.02 0.024 0.150 792 0.39 0.743 0.52 0.01 0.016 0.727 816 0,20 0.171 4.52 0.02 0.024 0.150 816 0.38 0.748 0.52 0.01 0.016 0/32 840 0.19 0.172 4.52 0.02 0.421 0.151 840 0.37 0.753 0.52 0.01 0.017 0.736 164 4.36 0.75$ 0.52 0.01 0.417 0.740 864 0.19 0173 4.52 0.02 0.422 0.161 888 4.36 0.762 0.52 0.01 0.018 0.745 888 0.19 0.174 4.52 0.02 0.022 0.152 912 0.18 0.175 4.52 0.42 0.023 0.152 912 4.35 0.767 0.52 0.01 0.018 0.749 936 0.34 0.771 0.52 0.01 0.019 0.753 936 0.18 0.176 0.52 0.02 0.023 0.153 960 0.34 0.775 0.52 0.01 0.019 0.756 960 0.17 0.177 0.52 0.02 0.024 0.153 984 0.17 0.178 0.52 0.02 0.024 0.154 984 0.33 0.780 0.52 0.01 0.020 0/60 1008 0.17 0.179 0.52 0.02 0.025 0.164 1008 0.32 0.784 0.52 0.01 0.024 0.764 1032 0.16 0.180 0.52 0.02 0.026 0.154 1032 0,32 0.788 0.52 0.01 0.020 0/67 1056 0,16 0.181 0.61 0.02 0.026 0.155 1056 0,31 0.792 0.51 0.01 0.021 0.771 1084 0.16 0.182 0.51 0.02 0.027 0.155 1080 0,31 0.796 0.51 0.01 0.021 0.774 1104 0.16 0.182 0.51 0.02 0.027 0.155 1104 0.30 0.799 0.51 0.01 0.022 0/78 1128 0,15 0.183 0.51 0.02 0.028 0.155 1128 0.30 0.843 0.51 0.01 0.022 0.781 1152 0.29 0.807 0.51 0.01 0.023 0.784 1152 0.15 0.184 4.51 0.02 0.028 0.156 1176 0.15 0.185 4.51 0.02 0.029 0.156 1176 0.29 0,811 0.51 0.01 0.023 0/87 1200 0.15 0.186 4.51 0.02 0.030 0.166 1200 0.28 0.814 0.51 0.01 0.424 0.790 1224 0.14 0.187 4.51 0.02 0.030 0.156 1224 0.28 0.818 0.51 0.01 0.024 0.794 1248 0.14 0.187 4.51 0.02 0.031 0.157 1248 0.27 0.821 0.51 0.01 0.025 0797 1272 0.14 0.188 4.51 0.02 0.431 0.157 1272 0.27 0.825 0.51 0.01 0.025 0.799 1296 0.27 0.828 0.51 0.01 0.026 0.802 1296 0.14 0.189 4.51 0.02 0.032 0.157 1320 0.26 0.831 0.51 0.01 0.026 0.805 1320 0.14 0.190 0.51 0.02 0,032 0.157 1344 0.13 0.190 0.51 0.02 0.033 0.167 1344 0.26 0.834 0.51 0.01 0.026 0.808 1368 0.13 0.191 0.51 0.02 0.034 0.158 1368 0.26 0.838 0.51 0.01 0.027 0.811 1392 0.13 0.192 0.51 0.02 0.434 0.158 1392 0,25 0.841 0.51 0.01 0.027 0.813 1416 4.13 0.193 4.51 0.02 0.035 0.158 1418 0.26 0.844 0.51 0.01 0.028 0.816 1440 0.24 0.847 0.51' 0.01 0.028 0.819 1440 4.13 0.193 4.51 0.02 0.035 0.158 Mod. FAA Minor Storage Volume (cubic ft) = 6,880 Mod. FAA Major Storage Volume (cubic ft) _ Mod. FAA Minor Storage Volume (acre -ft) = 0.1579 Mod. FAA Major Storage Volume (acre -ft.) = UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.35, Released January 2015 35,663 0.8187 Basin ID: f Volume (acre-feet) ud-detention v2.35 (1) , Modi fled FAA 312212422, 12:45 PM DETENTION VOLUME BY THE MODIFIED FAA METHOD 8711 COUNTY ROAD 23 RETENTION POND SIZING Inflow and Outflow Volumes vs. Rainfall Duration 0 1000 1200 1400 00GC°Co 'GOO 200 400 600 800 Duration (Minutes) -Minor Storm Inflow Volume . M$or Stonn Inflow Volume Minor Storm Outflow Volume —a— Major Storm Outflow Volume Minor Storm Storage Volume • Major Storm Storage Volume 1600 UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.35, Released January 2015 ud-detention u2.35 (1), Modi fled FAA 3:22:2022, 12:05 PM STAGE -STORAGE SIZING FOR DETENTION BASINS Project: 8711 COUNTY ROAD 23 Basin ID: Dam ---------_- Side Slope Z Side Slope Z L Flow Design Information (Input): Width of Basin Bottom, W = Length of Basin Bottom, L = Dam Side -slope (H:V), Zd = Stage -Storage Relationship: DZJM A ' Y 103.00 164.00 4.00 t Side Sloe Z ft ft ft/ft L Righ Isosceles Gird Side Slope L Check Basin Shape t Triangle Triangle tectangle e / Ellipse Irregular Storage Requirement from Sheet 'Modified FAA': Storage Requirement from Sheet 'Hydrograph': Storage Requirement from Sheet 'Full -Spectrum': Side Slope s 4 Side Skye OR... OR... OR... OR... (Use Overide values in cells +G32:52) MINOR MAJOR 0.16 0.82 ecru . acre -ft. Q.2*1.5!1.23ac. ft. Labels for WQCV, Minor, & Major Storage Stages r Di u e Water Surface Elevation ft ; I s ut: Side Slope (H:V) fttft Below El. (input% Basin I Width at Stage ft (output) Basin Length at Stage ft (output) Surface Area at Stage ft2 (output) Surface Area at Stage ft2 User Overide Volume Below Stage ft ut suti Surface Area at Stage acres (output) Volume Below Stage acre -ft (output) Target Volumes forWQCV, Minor, & Major Storage Volumes (for goal seek) 4927.00 103.00 164.00 20,574 0 0.472 0.000 4928.00 0.17 0.00 0.00 23,206 21,890 0.533 0.503 4929.00 0.17 0.00 0.00 25,960 46,473 0.596 1.067 100 YEAR 4929.30 0.17 0.00 0.00 27,827 54,541 0.639 1.252 4929.80 0.17 0.00 0.00 28,831 68,706 0.662 1.577 FREEBOARD 4930.30 0.17 0.00 0.00 28,822 83,119 0.662 1.908 #N IA 14N /A UN IA UN IA UN IA UN /A #1N /A UN /A #N IA #N IA #N IA #N /A #NIA #NIA UN /A UN /A UN /A UN /A UN /A #N IA UN /A #NIA UN /A #N IA #N IA #N IA #N /A UN /A #N /A UN /A UN /A #N IA #NIA #N IA #N /A #N /A UN IA UN IA UN IA UN /A UN IA UN /A #1 /A UN /A #N IA UN IA #N IA UN IA #N IA UN IA UN /A UN /A UN /A UN IA UN /A #N IA #N IA #N IA #N IA #NIA UN IA UN /A #N /A UN /A #N /A UN /A UN /A #N /A #N IA #N IA #N /A #N IA #N /A #N /A UN IA UN IA ud-detention_v2.35 (1), Basin 3/22/2022, 12:08 PM STAGE -STORAGE SIZING FOR DETENTION BASINS Project: Basin ID: STAGE -STORAGE CURVE FOR THE POND 4930.50 4930.00 4929.50 4929.00 a) a) a) cur) 4928.50 4928.00 4927.50 4927.00 4 _ 0.00 0.50 1.00 1.50 Storage (acre-feet) 2.00 2.50 ud-detention_v2.35 (1), Basin 3/22/2022, 12:08 PM STAGE -DISCHARGE SIZING OF THE SPILLWAY Project: 8711 County Road 23 Basin ID: 75.96 4.00000 Design Information (input): Bottom Length of Weir Angle of Side Slope Weir Elev. for Weir Crest Coef. for Rectangular Weir Coef. for Trapezoidal Weir Calculation of Spillway Capacity (output L= Angle = EL. Crest = Ct= 5.00 75.96 4,929.30 3.00 3.00 Water Surface Elevation ft. (linked) Rect. Weir Flowrate cfs (output) Triangle Weir Flowrate cfs (output) Total Spillway Release cfs (output) Total Pond Release cfs (output) 4927.00 0.00 0.00 0.00 0.00 4928.00 0.00 0.00 0.00 0.00 4929.00 0.00 0.00 0.00 0.00 4929.30 0.00 0.00 0.00 0.50 4929.80 5.30 2.12 7.42 #NIA 4930.30 15.00 12.00 27.00 #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #N/A 4N/A #NIA #NIA #NIA #N/A 4N/A #NIA #NIA #NIA #N/A 4N/A #NIA #NIA #NIA #N/A 4N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #N/A #NIA #NIA 4N/A #NIA #NIA #NIA #NIA #N/A #N/A #N/A #N/A #NIA #NIA #N/A #N/A #N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #NIA #N/A #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #N/A #N/A #N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA 4N/A #NIA #NIA #NIA #NIA #NIA #NIA #NIA #NIA #N/A #NIA #NIA #N/A #NIA #N/A #NIA #NIA #N/A #NIA #NIA #NIA #NIA #NIA feet degrees feet ud-detention_v2.35 (1), Spillway 3/22/2022, 12:09 PM Channel Report Hydraflow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc. SWALE CAPACITY (100-YR DEVELOPED FLOWS) Triangular Side Slopes (z:1) Total Depth (ft) Invert Elev (ft) Slope (%) N -Value Calculations Compute by: Known Q (cfs) Elev (ft) 4932.00 4931.50 4931.00 4930.50 4930.00 4929.50 3.00, 3.00 1.00 4930.30 1.07 0.025 Known Q = 7.20 Section Highlighted Depth (ft) Q (cfs) Area (sqft) Velocity (ft/s) Wetted Perim (ft) Grit Depth, Yc (ft) Top Width (ft) EGL (ft) Tuesday, Mar 22 2022 0.85 7.200 2.17 3.32 5.38 0.82 5.10 1.02 V 9 1 2 3 4 5 0 7 8 Depth (ft) 1.70 1.20 0.70 0.20 -0.30 -0.80 Reach (ft) Page 12 of 12 CIVIL ENGINEERING APPENDIX E: DRAINAGE PLANS Westminster, Co 80031 720.774.7736 www.raptor-eivilcom Hello