HomeMy WebLinkAbout20221396.tiffS• April 7, 2021. Jay Basiliere 13813 County Road 74 Eaton, Colorado 80615 LOGIC Re: Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption Al ►SE -1030 TBD County Road 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 Mr. Basiliere: Soilogic, Inc. (Soilogic) personnel have completed the geotechnical subsurface exploration you requested for the proposed single-family residence to be constructed on proposed Lot B, a part of amended subdivision exemption AM 1'SE-1030, near Eaton in unincorporated Weld County, Colorado. The results of our subsurface exploration and pertinent geotechnical engineering recommendations are included with this report. We understand the proposed residence will be a single -story wood frame structure constructed over a full basement and will include an attached garage with a slab -on -grade floor. Foundation loads for the structure are expected to be relatively light, with continuous wall loads less than 3.5 kips per lineal foot and individual column loads less than 75 kips. Small grade changes are anticipated to develop finish site grades in the residence area. The purpose of our exploration was to describe the subsurface conditions encountered in the completed site borings and develop the test data necessary to provide recommendations concerning design and construction of the residence foundation and support of floor slabs. The conclusions and recommendations outlined in this report are based on results of the completed field and laboratory testing and our experience with subsurface conditions in this area. Sollogic, Inc. 3522 Draft Horse Court • Loveland, Co 80538 • (970) 535-6144 Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 2 SITE DESCRIPTION The proposed residencewill be constructed on proposed Lot B, a part of Amended Subdivision Exemption AMD E-1030, located at an as -yet -to -be -determined address on the north side of County Road 74 near Eaton, in unincorporated Weld County, Colorado. At the time of our site exploration, the proposed ground surface in the proposed construction area contained a moderate growth of grass vegetation and was relatively level. The maximum difference in ground surface elevation across the residence footprint was estimated to be on the order of two (2) feet or less. Evidence of prior building construction was not observed in the proposed construction area by Soilogic personnel at the time of our site exploration. EXPLORATION AND TESTING PROCEDURES To develop subsurface information in the area of the proposed residence, two (2) soil borings were extended to a depth of approximately 15 feet below present site grade within the approximate residence footprint. The boring locations were established in the field by Soilogic personnel by referencing approximate building corner stakes which had been placed by the client. A diagram indicating the approximate boring locations is included with this report. The boring locations should be considered accurate only to the degree implied by the methods used by the client to establish the approximate building footprint in the field. Graphic logs of each of the auger borings are also included. The test holes were advanced using 4 -inch diameter continuous -flight auger, powered by a truck -mounted CME-45 drill rig. Samples of the subsurface materials were obtained at regular intervals using California barrel sampling procedures in general accordance with ASTM i specification D-1586. Penetration resistance measurements were obtained by driving the standard sampling barrel into the substrata using a 140 -pound hammer falling a distance of 30 inches. The number of blows required to advance the sampler a distance of 12 inches is recorded and helpful in estimating the consistency or relative density of the soils encountered. In the California barrel sampling procedure, lesser disturbed samples are obtained in removable brass liners. Samples of the subsurface materials obtained in the field were sealed and returned to the laboratory for further evaluation, classification and testing. Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 3 The samples collected were tested in the laboratory to measure natural moisture content and were visually andlor manually classified in accordance with the Unified Soil Classification System (USCS). The USCS group symbols are indicated on the attached boring logs. An outline of the USCS classification system is included with this report. As part of the laboratory testing, a calibrated hand penetrometer (CHP) was used to estimate the unconfined compressive strength of essentially -cohesive specimens. The CHP also provides a more reliable estimate of soil consistency than tactual observation alone. Dry density, Atterberg limits, -200 wash and swell/consolidation tests were completed on selected samples to help establish specific soil characteristics. Atterberg limits tests are used to determine soil plasticity. The percent passing the #200 size sieve (-200 wash) test is used to determine the percentage of fine-grained materials (clay and silt) in a sample. Swell/consolidation tests are performed to evaluate soil volume change potential with variation in moisture content. The results of the completed laboratory tests are outlined on the attached boring logs and swell/consolidation test summaries. SUBSURFACE CONDITIONS The materials encountered in the completed site borings can be summarized as follows. Approximately 3 to 6 inches of vegetation and topsoil was encountered at the surface at the boring locations. The vegetative soil layer was underlain by light brown to brown clayey to silty sand with trace amounts of gravel. The clayey/silty sand varied from very loose to medium dense in terms of relative density, exhibited no to low swell potential at current moisture and density conditions and extended to the full depth explored in both borings at a depth of approximately 15 feet below present site grade. Groundwater was not encountered in either boring to the full depth explored at a depth of about 15 feet below grade when checked immediately after completion of drilling. Groundwater levels will vary seasonally and over time based on weather conditions, site development, irrigation practices and other hydrologic conditions. Perched and/or trapped groundwater conditions may also be encountered at times throughout the year. Perched water is commonly encountered in soils overlying less permeable soil layers andlor bedrock. Trapped water is typically encountered within more permeable zones of layered Geotechnical Subsurface Exploration Report Proposed. Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road. 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 4 soil and bedrock systems. The location and amount ofperched/trapped water can also vary over time. ANALYSIS AND RECOMMENDATIONS General Careful observation of the exposed foundation bearing materials should be completed at the time of construction to ensure all footing foundations will be supported on like natural materials with suitable strength. If extensive zones of very loose/disturbed, high moisture content soils are encountered at that time, some o ere ..cavationibackfill or other approved stabilization procedures may be required prior to foundation construction. We would be happy to provide recommendations concerning subgrade stabilization at your request or should they be deemed necessary. Foundations Based on the materials encountered in the completed site borings and results of laboratory testing, it is our opinion the proposed lightly -loaded residence could be supported by continuous spread footing and isolated pad foundations bearing on natural, undisturbed clayey/silty sand with no to low swell potential. For design of footing foundations bearing on natural, undisturbed, loose to medium dense clayey/silty sand, we recommend using a maximum net allowable soil bearing pressure of 1,500 psf. As a precaution, the residence footings should be sized to maintain a minimum dead -load pressure of 500 psf, or as high as practical on the foundation bearing materials. Exterior footings should bear a minimum of 30 inches below finished adjacent exterior grade to provide frost protection. We recommend formed strip footings have a minimum width of 12 inches and isolated pad foundations have a minimum width of 24 inches in order to facilitate construction and reduce the potential for development of eccentrically loaded footings. Actual footing widths should be designed by a structural engineer. For design of footing foundations and foundation walls to resist lateral movement, a passive equivalent fluid pressure value of 275 pcf could be used. The top 30 inches of Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 5 subgrade could be considered a surcharge load but should not be used in the passive resistance calculations. A coefficient of friction of 0.45 could be used between foundation and floor slab concrete and the bearing soils to resist sliding. The recommended passive equivalent fluid pressure value and coefficient of friction do not include a factor of safety. We estimate settlement of footing foundations designed and constructed as outlined above and resulting from the assumed structural loads would be on the order of 1 inch or less. ifferential settlement could approach the amount of total settlement estimated above. Floor Slabs In the basement area of the residence, the floor slab could be supported directly on natural, undisturbed clayey to silty sand. The garage and any other at -grade floor slabs could be supported on reconditioned natural site sols and/or properly placed and compacted fill. All existing vegetation and topsoil should be completely removed from at -grade floor slab and any proposed fill areas. After stripping and completing all cuts and prior to placement of any fill or flatwork concrete, we recommend the exposed subgrade soils be scarified to a depth of 9 inches, adjusted to within the range of ±2% of standard Proctor optimum moisture content and compacted to at least 95% of the material's standard Proctor maximum dry density. Fill soils required to develop at -grade floor slab and exterior flatwork subgrades should consist of approved low -volume -change (LVC) soils free from organic matter, debris and other objectionable materials. Based on results of the completed laboratory testing, it is our opinion the native site clayey/silty sand could be used as fill in these areas provided care is taken to develop the proper moisture content in those materials at the time of placement and compaction. We recommend the site clayey/silty sand and/or similar soils be placed in loose lifts not to exceed 9 inches thick, adjusted in moisture content and compacted as previously outlined. The garage and any other at -grade floor slabs could be supported directly on the reconditioned subgrade soils and/or suitable fill soils placed and compacted as outlined above. Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road. 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 6 Care should be taken to maintain the proper moisture content in all floor slab subgrade soils prior to concrete placement. The developed at -grade floor slab subgrade soils should not be left exposed for extended periods of time. In the event that the subgrade soils are allowed to dry out or if rain, snowrnelt or water from any source is allowed to infiltrate those materials, reworking of the subgrade soils or removal/replacement procedures may be required. Floor slabs should be designed and constructed as floating slabs, separated from foundation walls, columns and plumbing and mechanical penetrations by the use of block outs or appropriate isolation material. Additionally, we recommend all partition walls supported above slabs -on -grade be constructed as floating walls to help reduce the potential for differential slab -to -foundation movement causing distress in upper sections of the structure. A minimum one and one-half (11/2) inch void space is recommended beneath all floating walls. Special attention to door and stair framing, drywall installation and trim carpentry should be taken to isolate those elements from the floor slabs, allowing for some differential floor slab -to -foundation movement to occur without transmitting stresses to the overlying structure. Depending on the type of floor covering and floor covering adhesive used in finished slab - on -grade areas (if any), a vapor barrier may be required immediately beneath the floor slabs in order to maintain flooring product manufacturer warranties. A vapor barrier would help reduce the transmission of moisture through the floor slab. However, the unilateral moisture release caused by placing concrete on an impermeable surface can increase slab curl. The amount of slab curl can be reduced by careful selection of an appropriate concrete mix; however, slab curl cannot be eliminated. We recommend the owner, architect and flooring contractor consider the performance of the slab, in conjunction with the proposed flooring products to help determine if a vapor barrier will be required and where best to position the vapor barrier in relation to the floor slab. Additional guidance and recommendations concerning slab -on -grade design can be found in American Concrete Institute (ACT) section 302. Geotechnical Subsurface Exploration Report Proposed. Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road. 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 7 Basement Construction We recommend a perimeter drain system be installed around all below -grade areas to help reduce the potential for water infiltration into the basement area and/or the development of hydrostatic pressures behind the below -grade walls. . perimeter drain system should consist of a 4 -inch diameter perforated drain pipe surrounded by a minimum of six (6.) inches of free -draining gravel. A filter fabric should be installed around the free -draining gravel or perforated pipe to reduce the potential for an influx of fine-grained soils into the system. The invert of the drain pipe, at its high point, should be placed at approximate foundation bearing level, run around the exterior perimeter of the below -grade area with a minimum slope of 14 -inch per foot to facilitate efficient water removal and should discharge to a sump pump and pit system. Care should be taken at the time of perimeter drain installation to avoid disturbing those soils providing support to the residence footing foundations (extending down at a 1:1 slope from the bottom edges of the footings). Backfill placed adjacent to below -grade walls should consist of LVC potential and relatively impervious soils free from organic matter, debris and other objectionable materials. The natural site clayey/silty sand soils could be used as backfill in this area, provided the proper moisture content in those materials at the time of placement and compaction. We recommend the natural site clayey/silty sand and/or similar backfill soils be placed in loose lifts not to exceed 9 inches thick, adjusted in moisture and compacted as outlined in the "Floor Slabs" section of this report. Excessive lateral stresses canbe imposed on foundation walls when using heavier mechanical compaction equipment. We recommend compaction of unbalanced foundation wall backfill soils be completed using light mechanical or hand compaction equipment. Lateral Earth Pressures For design of below -grade walls where preventative measures have been taken to reduce the potential for development of hydrostatic loads on the walls, we recommend using an at -rest equivalent fluid pressure value of 65 pounds per cubic foot. A modified active equivalent fluid pressure of 55 pounds per cubic foot could be used for partially restrained conditioned where some rotation of the below -grade walls must occur to develop the active Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 8 earth pressure state. That rotation can result in cracking of the below -grade walls typically in between corners and other restrained points. The amount of deflection of the top of the wall can be estimated at 0.5% times the height of the wall. Variables that affect lateral earth pressures include but are not limited to the shrink/swell potential of the backfill soils, backfill compaction and geometry, wetting of the backfill soils, surcharge loads and point loads developed in the backfill materials. The recommended equivalent fluid pressure values do not include a factor of safety or an allowance for hydrostatic loads. Use of expansive soil backfill, excessive compaction of the wall backfill or surcharge loads placed adjacent to the below -grade walls can add to the lateral earth pressures causing the equivalent fluid pressure values used in design to be exceeded. Drainage Positive drainage is imperative for satisfactory long-term performance of the proposed residence and associated site improvements. We recommend positive drainage be developed away from the structure during construction and maintained throughout the life of the site improvements, with twelve (12) inches of fall in the first 10 feet away from the residence. Shallower slopes could be considered in hardscape a areas. In the event that poor or negative drainage develops adjacent to the residence over time, the original grade and associated positive drainage outlined above should be immediately restored. Care should be taken in the planning of landscaping to avoid features which could result in the fluctuation of the moisture content of the foundation bearing and/or flatwork subgrade soils. We recommend watering systems be placed a minimum of 5 feet away from the perimeter of the site structure and be designed to discharge away from all site improvements. Gutter systems should be considered to help reduce the potential for water ponding adjacent to the building, with the gutter downspouts, roof drains or scuppers extended to discharge a minimum of 5 feet away from structural, flatwork and pavement elements. Water which is allowed to pond adjacent to site improvements can result in unsatisfactory performance of those improvements over time. Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road. 74, Weld County (Eaton), Colorado Soilogic Project # 21-1092 9 GENERAL COMMENTS This report was prepared based upon the data obtained from the completed site exploration, laboratory testing, engineering analysis and any other information discussed. The completed borings provide an indication of subsurface conditions at the boring locations only. Variations in subsurface conditions can occur in relatively short distances away from the borings. This report does not refect any variations which may occur across the site or away from the borings. If variations in the subsurface conditions anticipated become evident, the geotechnical engineer should be notified immediately so that further evaluation can be completed and when warranted, alternative recommendations provided. The scope of services for this project does not include either specifically or by implication any biological or environmental assessment of the site or identification or prevention of pollutants or hazardous materials or conditions. Other studies should be completed if concerns over the potential of such contamination or pollution exist. The geotechnical engineer should be retained to review the plans and specifications so that comments can be made regarding the interpretation and implementation of our geotechnical recommendations in the design and specifications. The geotechnical engineer should also be retained to provide testing and observation services during construction to help determine that the design requirements are fulfilled. This report has been prepared for the exclusive use of our client for specific application to the project discussed and has been prepared in accordance with the generally accepted standard of care for the profession. No warranties express or implied, are made. The conclusions and recommendations contained in this report should not be considered valid in the event that any changes in the nature, design or location of the project as outlined in this report are planned, unless those changes are reviewed and the conclusions of this report modified and verified in writing by the geotechnical engineer. Geotechnical Subsurface Exploration Report Proposed Lot B, A Part of Amended Subdivision Exemption AMDSE-1030 TBD County Road 74, Weld County (Eaton), Colorado Soilogic Project # 214092 10 We appreciate the opportunity to be of service to you on this project. If you have any questions concerning the enclosed information or if we can be of further service to you in any way, please do not hesitate to contact us. Very Truly Yours, Soilogic, Inc. Alec Kaljian, P.E. Project Engineer Reviewed by: Darrel DiCarlo, F.E. Senior Project Engineer APRIL 2021 PROJECT #21-1092 BORING LOCATION DIAGRAM ScL_sic7 APPROXIMATE LOCATION OF PROPOSEB RESIDENCE - B-2 PROPOSED LOT B PROPOSED LOT B, PART OF AMENDED SUBDIVISION EXEMPTION AMDSE-1030 TBD COUNTY ROAD 74, 'GELD COUNTY (EATON), COLORADO PROPOSED LOG OF BORING LOT B-1 B, A TBD PART COUNTY OF AMENDED ROAD 74, Project WELD April SUBDIVISION COUNTY # 21-1092 2021SDI'_ (EATON), COLORADO EXEMPTION AMDSE-'1030 LOGIC Sheet 1/1 Drilling Rig: CME 45 Water Depth Information Start Date 3/23/2021 Auger Type: 4" CFA During Drilling None Finish Date 3/23/2021 Hammer Type: Automatic After Drilling None Surface Elev. - Field Personnel: JL / BM - - 0 0, D SOIL DESCRIPTION Depth (ft) et "N" MC CM (pcf) DD Estimated (psi) q , % Swell 500 psf @ Swell Pressure (psf) Atterberg Limits % # Passing 200 Sieve (%) E LL PI 3-6" VEGETATION & TOPSOIL - SC-SM CLAYEY to SILTY SAND brown to light brown loose to medium dense 1 2 3 CS 28 4.7 110.5 900O+ 0.5% 800 - - - 4 5 CS 23 6.9 108.9 900O+ 1.1% 1700 16 8 26.5% 6 7 - 8 - 9 10 CS 8 17.2 104.9 900O+ None <500 - - - 11 12 13 14 15 CS 5 21.1 100.1 <500 - - - - - OF BORING @ 15.0' - 16 17 18 19 20 21 22 23 24 25 BOTTOM PROPOSED LOG OF BORING LOT El, A PART TBD COUNTY B-2 • AMENDED 74, WELD April SUBDIVISION COUNTY (EATON), /I 21-1092 2021 E COLORADO EMP'TI *IN AMDSE-1030 SOr LOGIC F ROAD Project Sheet 1/1 Drilling Rig: CME 45 Water Depth Information Start Date 3/23/2021 Auger Type: 4" CFA During Drilling None Finish Date 3/2312021 Hammer Type: Automatic After Drilling None Surface Elev. - Field Personnel: JL / BM - 0 ampler Estimated Swell % Passing O SOIL DESCRIPTION Depth "N" MC DD qu % Swell @ Pressure Atterberg Limits # 200 Sieve D (ft) (%) (pc (psf) 500 psf (psf) LL PI (%) 3-6" VEGETATION & TOPSOIL - 1 2 3 4 5 CS 21 7.6 110.6 9000+ 1.7% 1800 - - - 6 7 SC-SM CLAYEY to SILTY SAN D - brown to light brown 8 loose to medium dense - 9 10 CS 9 20.1 100.6 9000+ None <500 - - - 11 12 13 14 15 CS 6 19.3 104.0 <500 - - - - - OF BORING @ 15.0' - BOTTOM 16 17 18 19 20 21 22 23 24 25 PROPOSED LOT B, A PAT OF AMENDED SUBDIVISION EXEMPTION AMDSE-1030 TBD COUNTY ROAD 74, WELD COUNTY (EATON), COLORADO Project # 21-1092 April 2021 SWELL/CONSOLIDATION TEST SUMMARY 12 10 8 6 can 4 2 0 ca 0 c 0 0 0 -2 -4 -6 -8 - 10 - 12 10 dded Voter 100 1000 Applied Load (psf) 10000 100000 Sample ID: B-'1 @ 2 Sample Description: Light Brown Clayey to Silty Sand (S -SM) Initial Moisture 4.7% Liquid Limit - Final Moisture 20.3% Plasticity Index - % Swell @ 500 psf 0.5% % Passing #200 - Swell Pressure (psf) 800 Dry Density (pcf) 110.5 SCfjLOGIC PROPOSED LOT B, A PAT OF AMENDED SUBDIVISION EXEMPTION AMDSE-1030 TBD COUNTY ROAD 74, WELD COUNTY (EATON), COLORADO Project # 21-1092 April 2021 SWELL/CONSOLIDATION TEST SUMMARY Sample ID: B-1 @ 4 Sample Description: Light Brown Clayey to Silty Sand (SC -SPA) Initial Moisture 6.9% Liquid Limit 16 Final Moisture 22.5% Plasticity Index % Swell @ 500 psf 1.1% % Passing #200 26.5% Swell Pressure (psf) 1,700 Dry Density (pcf) 108.9 SOf..OSIC PROPOSED LOT B, A PAT OF AMENDED SUBDIVISION EXEMPTION AMDSE-1030 TBD COUNTY ROAD 74, WELD COUNTY (EATON), COLORADO Project # 21-1092 April 2021 SWELL/CONSOLIDATION TEST SUMMARY Sample ID: B-1 @ 9 Sample Description: Brown Clayey to Silty Sand (SC-SM) Initial Moisture 17.2% Liquid Limit - Final Moisture 16.1% Plasticity Index - % Swell @ 500 psf None % Passing #200 Swell Pressure (psf) <500 Dry Density (pcf) 104.9 SCfjLOGIC PROPOSED LOT B, A PAT OF AMENDED SUBDIVISION EXEMPTION AMDSE-1030 TBD COUNTY ROAD 74, WELD COUNTY (EATON), COLORADO Project # 21-1092 April 2021 SWELL/CONSOLIDATION TEST SUMMARY Sample ID: B-2 a"r 4 Sample Description: Light Brown Clayey to Silty Sand (SC-SM) Initial Moisture 7.6% Liquid Limit - Final Moisture 26.2% Plasticity Index - % Swell @ 500 psf 1.7% % Passing #200 - Swell Pressure (psf) 1,800 Dry Density (pcf) 110.6 SCfjLOGIC PROPOSED LOT B, A PAT OF AMENDED SUBDIVISION EXEMPTION AMDSE-1030 TBD COUNTY ROAD 74, WELD COUNTY (EATON), COLORADO Project # 21-1092 April 2021 SWELL/CONSOLIDATION TEST SUMMARY Sample ID: B-2 @ 9 Sample Description: Brown Clayey to Silty Sand (SC-SM) Initial Moisture 20.1% Liquid Limit - Final Moisture 19.1% Plasticity Index - % Swell @ 500 psf None % Passing #200 - Swell Pressure (psf) <500 Dry Density (pcf) 100.6 SCfjLOGIC UNIFIED Criteria for Assigning Group SOIL CLASSIFICATION and Group Names Using Laboratory SYSTEM Tests' Soil Classification Symbols Group Symbol Group Name' Coarse Grained Soils More than �, retained on No. 200 sieve Gravels More than 50% of coarse fraction retained on No. 4 sieve Clean Gravels Less than 5% fines Cu ≥ 4 and 1 s Cc s 3E GW Well graded gravel Cu < 4 and/or 1 › Cc > 3E GP Poorly graded gravelF Gravels with Fines More than 12% fines' Fines classify as ML or MH GM Silty graver.'" Fines classify as CL or CH GC Clayey graver" Sands 50% or more of coarse fraction passes No. 4 sieve Clean Sands Less than 5% fines° Cu ≥ 6 and 1 ≤ Cc s 35 SW Well graded sand' sand" Cu < 6 and/or 1 c. 3E SP Poorly graded Sands with Fines More than 12% fines° Fines classify as ML or MH SM Silty sandaH°" Fines classify as CL or CH SC Clayey sand"" Fine -Grained Soils 50% or more passes the No. 200 sieve Silts and Clays Liquid limit less than 50 Inorganic PI > 7 and plots on or above "A" line' CL Lean clay"` -M PI < 4 or plots below "A" line ML Si It'{ L':, Organic Liquid limit - oven dried < 0.75 OL Organic clay' Liquid limit - not dried Organic siltK -M'° Sifts and Clays Liquid limit 50 or more Inorganic PI plots on or above "A" line CH Fat claf`-T PI plots below "A" line MH Elastic sit" Organic Liquid limit - oven dried 0.75 OH Organic c ay"`.1-." Liquid limit - not dried organic satin" Highly organic soils Primarily organic matter, dark in color, and organic odor PT Peat A Based on the material Bit field sample contained or boulders, or both" to CGravels with 5 to 12% gravel with silt, GW-GC graded gravel with silt, °Sands with 5 to 12% fines sand with silt, SW -SC sand with silt, SP -SC poorly Cu = a E'sa ago Gc passing the 3 -in. (75 cobbles or boulders, group name. fines require dual well graded gravel GP -GC poorly graded require dual symbols: well graded sand graded sand (D_;,}: -mm) sieve or both, symbols: with clay, gravel SW-SM with clay, SP-SM with clay to group GC -GM, add OW -GM GP -GM with clay. name. or SC-SM. "with well well poorly "If fines cobbles ' If soil J If Atterberg graded K If soil poorly gravel, If soil graded "sand graded M If soil "gravelly" N PI ° PI P PI 0 PI are contains contains �} whichever contains y " to contains ≥ 4 and < 4 or plots on plots below plots organic, limits rou group to group plots below or above "A" ≥ 15 a ≥ on add 15% plot to 29% is predominant. 30% name. a 30 to name. or "A" "A" line. "with gravel, in shaded plus plus above line. line. organic add "with area, plus No. 200, No. 200 No. 200, "A„ line. fines" predominantly predominantly to group gravel" to group soil is a CL -ML, add "with sand" sand, name. name. silty clay. or "with add gravel, add D10 F If soil contains a 15% sand, Olt fines classify as CL -ML, X Dso add "with sand" use dual symbol 60 I For classification soils of coarse I and fine-grained -grained of "A" at P1=4 1=0.73 of "U" at LL=1 1=0.9 (LL - line (LL - line e to -8) I of soils to LL=25.5. -20) P l=7, fine-grained fraction I e/ } ,f` f /r 50 — Equation �,• ,, % # ,r }` r ' CiS . - s Horizontal X 40 ther W o Equation z Vertical > 30 ther H r f f r / C .' O o CD Co 20 r , l MH or OH 10 j, , ML or OL CL ,ML 7 0 a 13 16 20 30 40 LIQUID 50 LIMIT 80 (LLB 70 80 90 100 110 GENERAL NOTES DRILLING & SAMPLING SYMBOLS: SS: ST: RS: CS: BS: Split Spoon -1 %" I.D., 2" O.O.1 unless otherwise noted Thin -Walled Tube — 2.5" O.D., unless otherwise noted Ring Sampler - 2.47 I.D., 3" O.D., unless otherwise noted California Barrel - 1.92" I.D., 2.5" O.D., unless otherwise noted Bulk Sample or Auger Sample HS: . PA: HA: RB: WB: Hollow Stem Auger Power Auger Hand Auger Rock Bit Wash Boring or Mud Rotary The number of blows required to advance a standard 2 -inch G.D. split -spoon sampler (SS) the last 12 inches of the total 18 -inch penetration with a 140 -pound hammer falling 30 inches is considered the Standard Penetration" or"N-value". For 2.5" 0.D. California Barrel samplers (CB) the penetration value is reported as the number of blows required to advance the sampler 12 inches using a 140 -pound hammer falling 30 inches, reported as "blows per inch," and is not considered equivalent to the "Standard Penetration" or "N -value". WATER LEVEL MEASUREMENT SYMBOLS: WL: WCI: DCI: AB: Water Level Wet Cave in Dry Cave in After Boring WS: WO: BCR: ACR: While Samplling While Drilling Before Casing Removal After Casing Removal Water levels indicated on the boring logs are the levels measured in the borings at the times indicated. Groundwater levels at other times and other locations across the site could vary. In pervious soils, the indicated levels may reflect the location of groundwater. In low permeability soils, the accurate determination of groundwater levels may not be possible with only short-term observations. DESCRIPTIVE SOIL CLASSIFICATION: Soil classification is based on the Unified Classification System. Coarse Grained Soils have more than 50% of their dry weight retained on a #200 sieve; their principal descriptors are: boulders, cobbles, gravel or sand. Fine Grained Soils have less than 50% of their dry weight retained on a #200 sieve; they are principally described as clays if they are plastic, and silts if they are slightly plastic or non -plastic. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. In addition to gradation, coarse -grained soils are defined on the basis of their in -place relative density and fine-grained soils on the basis of their consistency. FINE-GRAINED SOILS Blows/Ft. <3 3-5 6-10 11-18 19-36 36 Blows/Ft. 0-2 3-4 5-8 9-15 16-30 >30 Consistenc Very Soft Soft Medium Stiff Stiff Very Stiff Hard COARSE -GRAINED SOILS Blows/Ft. 0-5 6-14 15-46 47-79 >79 RELATIVE PROPORTIONS OF SAND AND GRAVEL Descriptive Terms of Other Constituents Trace With Modifier Percent of Dry Weight <15 15-29 >30 RELATIVE PROPORTIONS OF FINES Descriptive Terms of Other Constituents Trace With Modifiers Percent of Dry Weight <5 5-12 >12 SS Blows/Ft. <3 4-9 10-29 30-50 >50 Relative Densit Very Loose Loose Medium Dense Dense Very Dense (CB) Blows/Ft. <24 24-35 36-60 61-96 >96 BEDROCK (SS) Blows/Ft. <20 20-29 30-49 50-79 >79 GRAIN SIZE TERMINOLOGY Major Component of Sample Boulders Cobbles Gravel Sand Silt or Clay Consistency Weathered Firm Medium Hard Hard Very Hard Particle Size Over 12 in. (300mm) 12 in. to 3 in. (300mm to 75 mm) 3 in. to #4 sieve (75mm to 4.75 mm) #4 to #200 sieve (4.75mm to 0.075mm) Passing #200 Sieve (0.075 mm) PLASTICITY DESCRIPTION Term Non -plastic Low Medium High Plasticity Index 0 1-10 11-30 30+ SC LCSIC Hello