HomeMy WebLinkAbout20220028.tiffMEMORANDUM TO: Kim Ogle, Planning Services FROM: Melissa J King, PE DATE: August 16, 2021 SUBJECT: PUDF21-0001 Martin Brothers PUD AM S-249 The Weld County Department of Public Works has reviewed this proposal. Staff comments made during this phase of the application process may not be all-inclusive, as other issues may arise during the remaining application process. COMMENTS: Parcel: Parcels associated with S-249 Martin Brothers PUD AM located at CR 37 at CR 10 The project proposes to: A Site Specific Development Plan and 2nd Amended Planned Unit Development Final Plan, PUD21-0001, to modify the conditionally approved PUD (S-249) with R-1 (Low Density Residential) Uses to PUD with R-1 (Low Density Residential) and A (Agricultural) Uses allowed as a Use by Right, Accessory Use, and uses allowed by permit in subdivisions and historic townsites. ACCESS: Weld County Public Works has reviewed the application materials related to access. The lots associated with Martin Brothers PUD AM S-249 have existing accesses onto Martin Street, Sunrise Lane, Clara Lee Street, Elizabeth Street, and Argie Street. No other accesses are requested. ROADS AND RIGHT-OF-WAY: Clara Lee Street and Elizabeth Street are paved roads and are designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as local roads, which require 60 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. Argie Street, Martin Street, and Sunrise Lane are gravel roads and are designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as local roads, which require 60 feet of right-of- way. The applicant shall delineate on the plan the future and existing right-of-way and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. The planned unit development is bounded on the east by County Road 37. County Road 37 is a paved road and is designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as a collector road, which requires 80 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. The planned unit development is bounded on the south by County Road 10. County Road 10 is a paved road and is designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as a local road, which requires 60 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. Per Chapter 8, Article 13, Section 8-13-30, a Weld County Right -of -Way Use Permit is required for any project that will be occupying, constructing or excavating facilities within, and or encroaching upon, any County rights -of -way or easement. Right -of -Way Use Permit instructions and application can be found at https://www.weldgov.com/departments/public works/permits!. Weld County will not replace overlapping easements located within existing right-of-way or pay to relocate existing utilities within the County right-of-way. CONDITIONS OF APPROVAL: The plan shall be amended to delineate the following: Clara Lee Street and Elizabeth Street are paved roads and are designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as local roads, which require 60 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way (along with the documents creating the right-of-way) and the physical location of the road. If the right-of- way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of- way. This road is maintained by Weld County. (Department of Public Works) 2. Argie Street, Martin Street, and Sunrise Lane are gravel roads and are designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as local roads, which require 60 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way (along with the documents creating the right-of-way) and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. (Department of Public Works) 3. The planned unit development is bounded on the east by County Road 37. County Road 37 is a paved road and is designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as a collector road, which requires 80 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way(along with the documents creating the right-of-way) and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. (Department of Public Works) 4. The planned unit development is bounded on the south by County Road 10. County Road 10 is a paved road and is designated on the Weld County Functional Classification Map (Code Ordinance 2017-01) as a local road, which requires 60 feet of right-of-way. The applicant shall delineate on the plan the future and existing right-of-way (along with the documents creating the right-of-way) and the physical location of the road. If the right-of-way cannot be verified it shall be dedicated or reserved per Weld County Code. Pursuant to the definition of setback in the Weld County Code Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the right-of-way. This road is maintained by Weld County. (Department of Public Works) 5. Show and label the existing permitted access points and the usage types (e.g. Residential). (Department of Public Works) DEVELOPMENT STANDARDS (NOTES ON THE PLAT) 1. The property owner or operator shall be responsible for controlling noxious weeds on the site, pursuant to Chapter 15, Article I and II, of the Weld County Code. (Department of Public Works) 2. Weld County will not replace overlapping easements located within existing right-of-way or pay to relocate existing utilities within the existing County right-of-way. (Department of Public Works) 3. Access on the site shall be maintained to mitigate any impacts to the public road including damages and/or offsite tracking. (Department of Public Works) 4. Any work that may occupy and or encroach upon any County rights -of -way or easement shall acquire an approved Right -of -Way Use Permit prior to commencement. (Department of Public Works) 5. The historical flow patterns and runoff amounts will be maintained on the site. (Department of Public Works) WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT c u rY 1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth.org Memorandum To: Kim Ogle From: Lauren Light, Environmental Health Services Date: August 23, 2021 Re: PUDF21-0001 Multiple Owners within the Martin Brothers PUD Environmental Health Services has reviewed this proposal for a Site Specific Development Plan and 2nd Amended Planned Unit Development Final Plan, PUD21- 0001, to modify the conditionally approved PUD (S-249) with R-1 (Low Density Residential) Uses to PUD with R-1 (Low Density Residential) and A (Agricultural) Uses allowed as a Use by Right, Accessory Use, and uses allowed by permit in subdivisions and historic townsites. Individual wells provide water and on -site wastewater treatment systems provide sewer. Environmental Health Services has no objections to adding agricultural uses to the PUD. We recommend the following appear as notes on the amended final plat: 1. Water service may be obtained from an appropriately permitted well. 2. The parcel is currently not served by a municipal sanitary sewer system. Sewage disposal may be by septic systems designed in accordance with the regulations of the Colorado Department of Public Health and Environment, Water Quality Control Division, and the Weld County Code in effect at the time of construction, repair, replacement, or modification of the system. 3. Activity or use on the surface of the ground over any part of the OWTS must be restricted to that which shall allow the system to function as designed and which shall not contribute to compaction of the soil or to structural loading detrimental to the structural integrity or capability of the component to function as designed. Health Administration Public Health & Environmental Health Vital Records Clinical Services Services Icic: 9/U 304 6410 Ice: 9:0 304 6420 Tele: 970-304-6415 Fax: 9/0-301-6412 Fax: 5 i 0-301-64 1 6 Fax. 970-304-641 Communication, Emergency Preparedness Education & Planning g Response Tele: 970-.304-6470 Tele: 970-304-6470 Fax: 970-304-6452 Fax: 970-304-6452 Public Health MEMORANDUM To: Kim Ogle, Principal Planner August 11, 2021 From: Bethany Pascoe, Zoning Compliance Officer Subject: PUDF21-0001 Referral Prior to submittal of this Planned Unit Development (PU DF21-0001) application, 3 Zoning Violations were submitted. • ZCV20-00205 @ 17543 Clara Lee St (Property Owner = Castillo, Jose). Complaint: Animal Units and Commercial Vehicle. Mr. Castillo removed the excess animal units and the impermissible Commercial Vehicle. The Violation case was closed. • ZCV20-00242 @ 17723 Clara Lee St (Property Owner = Quezada, Felipe). Complaint: Animal Units. Mr. Quezada's case is currently open. He explained that he currently has 3 horses. • ZCV20-00241 @ 17583 Clara Lee St (Property Owner = Brandt, Mark). Complaint: Cargo Containers & too many horses. I could not validate the claim regarding too many horses, but the cargo containers are present. This violation remains open. Approval of this application will provide additional options for the above open violations either to be brought immediately into compliance or to submit building permit applications and thus correcting the violation. Denial of this application will require the current property owners of Martin PUD to meet the R-1 (Residential) standards as initially permitted. These Violations have NOT been forwarded to the County Attorney's Office. Staff has no comment for or against this PUDF request. SERVICE. TEAMWORK. INTEGRITY. QUALITY Submit by Email Weld County Referral August 11, 2021 The Weld County Department of Planning Services has received the following item for review: Applicant: Multiple Owners within the Case Number: PUDF21-0001 the Martin Brothers PUD Please Reply By: September 8, 2021 Planner: Kim Ogle Project: A Site Specific Development Plan and 2nd Amended Planned Unit Development Final Plan, PUD21-0001, to modify the conditionally approved PUD (S-249) with R-1 (Low Density Residential) Uses to PUD with R-1 (Low Density Residential) and A (Agricultural) Uses allowed as a Use by Right, Accessory Use, and uses allowed by permit in subdivisions and historic townsites. Parcel Number: Multiple Parcels Legal: LOTS 1 TO 23 MARTIN BROS PUD -AMENDED PLAT, PART OF SECTION 12, T1 N, R66W OF THE 6TH P.M., WELD COUNTY, COLORADO. Location: West of and adjacent to County Road 37, north of County Road 10 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does / does not comply with our Comprehensive Plan because: 0 We have reviewed the request and find no conflicts with our interests. OSee attached letter. Signature Weld County Oil and Gas Energy Department Agency Date 09/08/2021 Weld County Planning Dept. 1555 N. 17th Ave, Greeley, CO 80631 (970)-440-6100 (970)-304-6498 fax Weld County Oil & Gas Energy Department Referral Comments Referring Agency: Weld County Department of Planning Services Reference Number: PUDF21-0001 Associated Parcel: multiple parcels OGED Reviewer: Jennifer Teeters Review Date: September 7, 2021 The Staff of the Weld County Oil and Gas Energy Department (OGED) appreciates the opportunity to comment on the captioned planning case. Staff has completed review of the proposal and have no conflicts with the proposed activity. We have included additional comments below: 1. There are no active or proposed 1041 WOGLA Permits on the associated parcel. There are several oil and gas well sites in the area surrounding the parcel. 2. The surrounding parcel includes 2 active oil and gas wells, listed in Table 1 below. OGED requests that the Applicant coordinate operations in proximity to existing wells and production facilities with the operator(s) of these wells. API Operator Well Title Well Status 05-123-39593 Kerr McGee Oil & Gas Onshore LP STEWARD #34N-6HZ PR 05-123-39596 Kerr McGee Oil & Gas Onshore LP STEWARD #13C-6HZ PR 05-123-39595 Kerr McGee Oil & Gas Onshore LP STEWARD #13N-6HZ SI 05-123-39594 Kerr McGee Oil & Gas Onshore LP STEWARD #35C-6HZ PR 05-123-39589 Kerr McGee Oil & Gas Onshore LP STEWARD #35N-6HZ PR 05-123-39591 Kerr McGee Oil & Gas Onshore LP STEWARD #14C-6HZ PR 05-123-39592 Kerr McGee Oil & Gas Onshore LP STEWARD #14N-6HZ PR 05-123-39590 Kerr McGee Oil & Gas Onshore LP STEWARD #36C-6HZ PR 05-123-39597 Kerr McGee Oil & Gas Onshore LP STEWARD #36N-6HZ PR 05-123-46247 Kerr McGee Oil & Gas Onshore LP VERDE #13-7HZ PR 05-123-46256 Kerr McGee Oil & Gas Onshore LP VERDE #13-8HZ PR 05-123-46252 Kerr McGee Oil & Gas Onshore LP VERDE #13-9HZ PR 05-123-46254 Kerr McGee Oil & Gas Onshore LP VERDE #13-10HZ PR 05-123-46248 Kerr McGee Oil & Gas Onshore LP VERDE #13-11HZ PR 05-123-46255 Kerr McGee Oil & Gas Onshore LP VERDE #13-12HZX PR 05-123-46250 Kerr McGee Oil & Gas Onshore LP VERDE #13-13HZ PR 05-123-46251 Kerr McGee Oil & Gas Onshore LP VERDE #13-14HZ PR 05-123-46253 Kerr McGee Oil & Gas Onshore LP VERDE #13-15HZ PR 05-123-46257 Kerr McGee Oil & Gas Onshore LP VERDE #13-16HZ PR 05-123-46249 Kerr McGee Oil & Gas Onshore LP VERDE #13-17HZ PR 05-123-46258 Kerr McGee Oil & Gas Onshore LP VERDE #13-18HZ PR 3. The surrounding parcels include two (2) plugged and abandoned (P&A) well listed in Table 2 below. Additional information regarding this P&A well is available from the Colorado Oil and Gas Conservation Commission (COGCC). OGED recommends that the Applicant review this information and contact the responsible operator regarding well infrastructure that may have been abandoned in place prior to conducting operations in close proximity to the wells. Table 2. API Operator Well Title Well Status 05-123-23174 Kerr McGee Oil & Gas Onshore LP PILKINGTON #31-13D PA 05-123-23711 Kerr McGee Oil & Gas Onshore LP PILKINGTON #41-13D PA 4. The PUD lands may include additional oil and gas related infrastructure, such as off -location flowlines or pipeline which are a use by right and not regulated by Weld County. OGED requests that the applicant reviews flowline data available from the COGCC map viewer and utilize Colorado 811 prior to any excavation activities. These comments and recommendations are based upon the review of the application materials submitted by the applicant and other relevant information available on the E -Permit site. H Your Touchstone Energy' Cooperative At September 13, 2021 Weld County Planning Dept. 1555 N. 17th Ave Greeley, CO 80631 (970)-440-6100 (970)-304-6498 fax Re: Martin Bros. PUD Amendment Dear Kim Ogle: On behalf of United Power, Inc., thank you for inviting us to review and comment on the Martin Bros. PUD Amendment. After review of the information, we have the following comments: • Lot Distribution — United Power requires continuous dry utility easements for reliable electric facility installation. This allows us to install electric facilities in a continuous manner for our loop feed which provides reliability. We will needs' to 10' wide dry utility easements where the 5' UE's are in the screenshot below, due to the fact 5' does not give us enough room in between lots with the fence. .MF VRI 'Y. 9 — -- rl AMA I CC Croc r — I I Av" 7 X001 Acrtj 4 ' OC4 Acre AQ3E hero 0 w 5.000 btvx �` O 16 IS ao 22 I C3 ry 539b 6c -� unrr 0rrrgc E�F�wN $ 17 5 p A399 Avn 5.1 A d oF ARGIE aw-nrRgrsTREEE ii N@ro'4W — b 50.00" w 19 21 53"49- t3 4944 Au seta '--n 9;Sn acr.3 t4di drrrp Q r- °. EMirciYA I R -J N � eww e in ti Dr R NI ... .... i w .. Easements utilized by United Power cannot be encumbered by any hard surfaces such as streets or sidewalks. Although the roadways/tracts on the plat are dedicated to utilities, we have above ground equipment that cannot be placed within these areas. In addition, sidewalks take away from the use of the easement & reduces the area, limiting where our equipment can be placed. • Streetlights— When streetlight locations are identified in a subdivision, we need a 5' wide dry utility easement along one side of the lot closest to the streetlight location. All streetlight locations must be approved and signed off by the city/town, etc. Please note, if we do not get these through the platting process, we will have to get individual ones during the design which will slow United Power's ability to start construction significantly. Please have the property owner/developer/contractor submit an application for new electric service, any modification to existing facilities including relocation and/or removal along with CAD data via https://www.unitedpower.com/construction. United Power would like to work with these persons early in the construction process on getting an electric design prepared so that we can request any additional easements needed and hopefully have those easements dedicated on the plat rather than obtaining separate instrument. Obtaining easements via a separate instrument can be time consuming and could cause delays. UNITED POWER, INC. 500 Cooperative Way ■ Brighton. CO 80603 303-659-0551 i 800-468.8809 ■ fax 303.659-2172 www.unitedpower.com Asa Reminder: No permanent structures are acceptable within the dry utility easement(s); such as, window wells, wing walls, retaining walls, basement walls, roof overhang, anything affixed to the house like decks, etc. United Power considers any structure that impedes the access, maintenance, and safety of our facilities a permanent structure. No exceptions will be allowed, and any encroachments could result in penalties. Service will be provided according to the rules, regulations, and policies in effect by United Power at the time service is requested. We would like to remind the developer to call the Utility Notification Center by dialing 811 to have all utilities located prior to construction.. We look forward to safely and efficiently providing reliable electric power and outstanding service. Thank you, Amber Mendoza, RWA ROW Agent 720.249.9315 I platreferral@unitedpower.com CCOLORADO Division of Water Resources Dcoartmcnt of Natural Rcscurccs August 18, 2021 Kim Ogle, Planner Weld County Department of Planning Services Transmission via email: koglec weldgov.com Re: Martin Brothers PUD Case No. PUDF21-0001 Lots 1 to 23 Martin Bros PUD in part of Sec. 12, T1 N, R66W, 6th P.M. Water Division 1, Water District 2 Dear Kim Ogle: We have received your August 11, 2021 submittal concerning the above referenced proposal for a site specific development plan and 2" d amended planned unit development final plan to modify the conditionally approved PUD with R-1. Based on the referral information the request is the result of several violations within the subdivision as described in the October 28, 2020 letter from Weld County. This referral does not appear to qualify as a "subdivision" as defined in section 30-28-101(10)(a), C.R.S. Therefore, pursuant to the State Engineer's March 4, 2005 and March 11, 2011 memorandums to county planning directors, this office will only perform a cursory review of the referral information and provide informal comments. The comments do not address the adequacy of the water supply plan for this project or the ability of the water supply plan to satisfy any County regulations or requirements. In addition, the comments provided herein cannot be used to guarantee a viable water supply plan or infrastructure, the issuance of a well permit, or physical availability of water. According to the information provided, and the records available in the State Engineers office, the following wells are located on the subject parcels. The wells must operate in accordance with the terms and conditions on the well permits. Lot 1 - 178352-A Lot 2- 183859 Lot 3- 175808 Lot4- - 179045 LotS- - 193296 Lot6- - 172398 Lot7- - 179265 Lot8- - 174771 Lot 9- 203510 Lot 10 - 175652 Lot 11 - 175331 Lot 12 - 185084 Lot 13- 176362 Lot 14- 184997 Lot 15- 175243 Lot 16- 174772 tti : 1313 Sherman Street, Room 821, Denver, CO 80203 P 303.866.3581 www.colorado.gov/water I I Jared Polls, Governor Dan Gibbs, Executive Director I Kevin G. Rein, State Engineer/Director „ PUDF21-0001 Page 2 of 2 August 18, 2021 Lot 17- 199535 Lot 18- none Lot 19- 185249 Lot 20 - 180758 was issued for the lot, however we have not received a well construction report for the well. If a well was constructed under permit no. 180758 then a well construction report showing the well was constructed during the period when the permit was valid must be submitted to the State Engineers Office. Lot 21 - 186182 Lot 22 - 159324-A - This well was constructed as a replacement for well 159324. Condition 3 of well permit no. 159324-A required that well 159324 be plugged in accordance with Rule 16 of the Water Well Construction Rules within ninety days of completion of the new well. Our office has not received evidence that well 159324 was plugged as required. The well owner must provide a Well Abandonment Report (form GWS-09) to our office to demonstrate that the well was plugged in accordance with the Water Well Construction Rules. Lot 23 - 204458 If you or the applicant have any questions, please contact me on at 303-866-3581 x8265 or at Joanna.Williams@state.co.us. Sincerely, Ir 1 u4 Joanha Williams, P.E. Water Resources Engineer Ec: Referral no. 28825 Permit files Hello