Loading...
HomeMy WebLinkAbout20222339.tiffWELD LABORATORIES, INC. 1527 First Avenue • Greeley, Colorado 80631 Phone: (970) 353-8118 • Fax: (970) 353-1671 www.weldlabs.com February 25, 2022 Quality Well & Pump Attn: Kristie Davis 23275 US Hwy 85 La Salle, CO 80645 Client Name: TJ Heuper Laboratory No. E22046-1 Sample Name: Windmill PO#: 2022-253 Results Human Quality Threshold Calcium (ppm) Magnesium (ppm) Sodium (ppm) Hardness (ppm) (in grains/gallon) Sodium Adsorption Ratio Sulfate -S (ppm) Chloride (ppm) Total Dissolved Solids (ppm) pH (SI) Conductivity (mS/cm) Potassium (ppm) Iron (ppm) Nitrate -N (ppm) Total Coliforms (cfu/100ml) E. Coll (cfu/100ml) Total Alkalinity as CaCO3 (ppm) Hydroxide Alkalinity as CaCO3 (ppm) Carbonate Alkalinity as CaCO3 (ppm) Bicarbonate Alkalinity as CaCO3 (ppm) 20.2 4.9 266.0 71 4.1 13.8 76.6 81.5 844.8 8.28 1.32 3.2 < 0.1 1 < 1 < 1 245.1 0.0 0.0 245.1 NA NA NA NA NA NA <250 < 250 < 500 6.5 - 8.5 < 0.780 NA < 0.3 <10 < 1 < 1 NA NA NA NA Note: NA r• Not Applicable. The EPA doesn't provide limits for Na, Mg, Ca. For irrigation water we recommend Hardness < 120 ppm, SAR < 14 Project Manager /s/�z Date Sampling procedures can affect the value of analytical results - customers are advised to use appropriate sampling protocol to ensure samples are truly representative or the bulk sample. Quality Well & Pump 39525 Hwy 85 Ault, CO 80610 Phone (970)353-3118 Phone: (970)356-7842 Fax: 970-284-6445 Lic. # 1461 Alles Taylor & Duke. LLC 3610 35th Ave.. Unit 46 Evans, CO 80620 Date of Service: Location of Water Well: Well Permit Number: Service Provided: February 18, 2022 February 14. 2022 Cr 63 & CR 84 (utm 545624n 4493856e) 153242-A Water Well Production Test On February 14, 2022 Quality Well and Pump Traveled to a windmill located near County Road 63 & County Road 84 and performed a production test on an existing well. We removed the existing windmill and installed our testing equipment to a depth of 220 and stabilized the production to obtain a production rate. Listed below are our findings. Well Casing Diameter: Static Water Level: Well Depth: Production Test: Water Analysis: 5" 53' 230' The pumping system stabilized at a rate of 7 gallons per minute from a pumping level of 210" within 60 minutes of continuous flow and maintained that production for an additional 60 minutes of continuous flow. Water samples were obtained and transported to Weld Laboratories for Analysis, the complete report will be provided upon completion. Please contact our office with any questions or concerns regarding this report. Sincerely, Kristie Davis Domestic Pump Department Manager Hello