HomeMy WebLinkAbout20233631.tiff rol = ! WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT
J 1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth,org
Septic Permit New
Application Number: SP-2100219
Owner Name: S&L LTD
Site Address: 11352 CR 84
WELD, CO
App Type: Health\Commercial\New OWTS\Septic Application Status:
ERIN KRESS Final Pending
THENGINEERING LLC Applied Date:
PO BOX 337748 06/02/2021
GREELEY, CO 80633 Intake Person:
SCERRILLO
Parcel Number: 070512100016-R4349706 Permit Expiration Date:
Legal Desc: PT N2 12-7-67 LOT B REC EXEMPT RE-4332 9/24/2022
Work Description: OFFICE/MILK MIXING BUILDING
EHS SEPTIC GENERAL:
Application Date 06/02/2021
Number of Persons 19
Parcel Acres 106.23
Public Water Supply Yes
Public Water Supply Utility NWCWD
Septic Permit Expiration Date 9/24/2022
EHS PERC TEST(SITE) :
% Ground Slope 4
Engineer Design Required Yes
In 100 Year Flood Plain No
Limiting Zone Feet 8
Limiting Zone Qualifier Greater Than
Long Term Acceptance Rate 0.2
Profile Pits 3 or More
Slope Direction Southwest
Soil Description Sandy Lean Clay
Soil Type 4
Soil Type Suitable Yes
Treatment Level Level 1
Page 1 of 2
Health Admink iation Public Health& Environmental Health Cammvnkcallan, Emergency Preparedness
Vital Records Clinical Services Services Education R Planning d Response
Tete:970-304.64 ID Tele:9 70:304-6420 Tele:970-304-6415 Tele:970-304-6470 fele:970-304-6470
Fax: 970.304-6412 Fax: 970-334-64)6 Fax: 970-304.64i) Fax: 970-304-6452 Fan= 970-304-6452 Public Health
SEPTIC SIZING INFORMATION:
From the application information supplied and the on-site soil percolation data the following minimum installation
specifications are required according to the Engineer's evaluation:
Engineer's Specified Installation Recommendations:
Absorption Bed 1596
Engineer Design Chamber Specified Quick4 Plus Standard
Engineer Design Number of Chambers Specified 133
Engineer Septic System Design Type Specified Chambers-Bed
Septic Tank Size 1000
CONDITIONS:
Description: Commercial OWTS
Comment: Onsite wastewater treatment system must be 10 feet from property line. Install the soil
treatment area within 50 feet of the soils test location. Construct onsite wastewater
treatment system according to Engineer design. Septic tank must be at least 10 feet from
any potable water line, unless water line is encased. Building sewer or effluent lines must be
at least 5 feet from any potable water line, unless water line or sewer line are encased. Soil
treatment area must be 25 feet from any potable water line, unless water line is encased.
Sewer line to septic tank must have at least 1/8inch/ft.fall. Effluent line from septic tank to
distribution box must have at least 1/8inch/ft. fall. Effluent lines shall be placed into top inlet
portion of chamber. Install inspection ports at the ends of each trench or corners of each
bed. An engineer approval letter approving system as installed per engineer design is
required. Engineer designed OWTS must be inspected by the design Engineer prior to
backfilling. All Weld County regulations are applicable.
INSPECTION RESULT:
Description: Site Status: Approved to Issue
Comment:
NOTICE
This permit is granted temporarily to allow construction to commence.This permit may be revoked or suspended by the Weld County Department of
Public Health and Environment for reasons set forth in the Weld County Onsite Wastewater Treatment System Regulations including failure to meet
any term or condition imposed thereon during temporary or final approval.The issuance of this permit does not constitute assumption by the
department or its employees of liability for the failure or inadequacy of the sewage disposal system.This permit is nenransfarable and non-
refundable.Before issuing final approval of this permit the Weld County Department of Public Health and Environment reserves the right to impose
additional terms and conditions required to meet our regulations on a continuing basis.Final permit approval is contingent upon the final inspection
of the completed system by the Weld County Department of Public Health and Environment.
Alex Clemments September 21, 2021
Environmental Health Specialist Date
Page 2 of 2
Health Administration Publk Health& Environmental Health Communication, Enwrgvncy Preparedness
Vital Records Clinical Services Services Education&Planning &Response
kjo:97O34-6410 tele:970-3004.6420 Tele:970-30.1-64x5 Tele:970-304-6470 fele:910304-64141
Fa;.: 970-K4-6412 Sax: 970-304-6;46 Fnn; 973.304-6411 Fox: 9703-04-6452 F.3xL 970-3C-4-6452
Public Health
/O � ,`- ,, NORTH WELD COUNTY WATER DISTRICT
I. t r 0 P.O. BOX 56
k, k 10‘1 32825 CR 39 '5
__ /° LUCERNE, CO 80646
PHONE:(970)356-3020 • FAX:(970)395-0997 • E-MAIL:water@nwcwd.org
ACCOUNT NUMBER NAME AND SERVICE ADDRESS BILLING PERIOD
ABCD LANDCO LLC
6537000 40893 CR 252/17/2023-03/21 /2023
AULT, CO 80610 (/-).(/-). /
1116 Water Class P (KGal )
70 % of 17.000 Acre Feet 3,878
Transferred Water 0
Allocation Adjustment 0
Less YTD Usage 4,438
Remaining Water Allocation -560
Plant Investment Class
70 % of 16.000 Acre Feet 3,650
Less YTD Usage 4,438
Remaining PI Allocation -788
Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar
Prey. Read Curr. Read Usage Unit Amount
Previous Balance 6,916.07
02/17/2023 Payment - -3,705.95
03/14/2023 Payment - -6,916.07
03/21 /2023 Commercial - Industrial 9144 10062 918 kgal 4,075.92
Water Allocation Surcharge P 3,360.00
Plant Investment Surcharge - Tier 1 (788 KGal @ $3.95) P 3,112.60
Current Amount 10,548.52
Total Amount Due - 6,842.57