HomeMy WebLinkAbout20233631.tiff rol = ! WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT J 1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth,org Septic Permit New Application Number: SP-2100219 Owner Name: S&L LTD Site Address: 11352 CR 84 WELD, CO App Type: Health\Commercial\New OWTS\Septic Application Status: ERIN KRESS Final Pending THENGINEERING LLC Applied Date: PO BOX 337748 06/02/2021 GREELEY, CO 80633 Intake Person: SCERRILLO Parcel Number: 070512100016-R4349706 Permit Expiration Date: Legal Desc: PT N2 12-7-67 LOT B REC EXEMPT RE-4332 9/24/2022 Work Description: OFFICE/MILK MIXING BUILDING EHS SEPTIC GENERAL: Application Date 06/02/2021 Number of Persons 19 Parcel Acres 106.23 Public Water Supply Yes Public Water Supply Utility NWCWD Septic Permit Expiration Date 9/24/2022 EHS PERC TEST(SITE) : % Ground Slope 4 Engineer Design Required Yes In 100 Year Flood Plain No Limiting Zone Feet 8 Limiting Zone Qualifier Greater Than Long Term Acceptance Rate 0.2 Profile Pits 3 or More Slope Direction Southwest Soil Description Sandy Lean Clay Soil Type 4 Soil Type Suitable Yes Treatment Level Level 1 Page 1 of 2 Health Admink iation Public Health& Environmental Health Cammvnkcallan, Emergency Preparedness Vital Records Clinical Services Services Education R Planning d Response Tete:970-304.64 ID Tele:9 70:304-6420 Tele:970-304-6415 Tele:970-304-6470 fele:970-304-6470 Fax: 970.304-6412 Fax: 970-334-64)6 Fax: 970-304.64i) Fax: 970-304-6452 Fan= 970-304-6452 Public Health SEPTIC SIZING INFORMATION: From the application information supplied and the on-site soil percolation data the following minimum installation specifications are required according to the Engineer's evaluation: Engineer's Specified Installation Recommendations: Absorption Bed 1596 Engineer Design Chamber Specified Quick4 Plus Standard Engineer Design Number of Chambers Specified 133 Engineer Septic System Design Type Specified Chambers-Bed Septic Tank Size 1000 CONDITIONS: Description: Commercial OWTS Comment: Onsite wastewater treatment system must be 10 feet from property line. Install the soil treatment area within 50 feet of the soils test location. Construct onsite wastewater treatment system according to Engineer design. Septic tank must be at least 10 feet from any potable water line, unless water line is encased. Building sewer or effluent lines must be at least 5 feet from any potable water line, unless water line or sewer line are encased. Soil treatment area must be 25 feet from any potable water line, unless water line is encased. Sewer line to septic tank must have at least 1/8inch/ft.fall. Effluent line from septic tank to distribution box must have at least 1/8inch/ft. fall. Effluent lines shall be placed into top inlet portion of chamber. Install inspection ports at the ends of each trench or corners of each bed. An engineer approval letter approving system as installed per engineer design is required. Engineer designed OWTS must be inspected by the design Engineer prior to backfilling. All Weld County regulations are applicable. INSPECTION RESULT: Description: Site Status: Approved to Issue Comment: NOTICE This permit is granted temporarily to allow construction to commence.This permit may be revoked or suspended by the Weld County Department of Public Health and Environment for reasons set forth in the Weld County Onsite Wastewater Treatment System Regulations including failure to meet any term or condition imposed thereon during temporary or final approval.The issuance of this permit does not constitute assumption by the department or its employees of liability for the failure or inadequacy of the sewage disposal system.This permit is nenransfarable and non- refundable.Before issuing final approval of this permit the Weld County Department of Public Health and Environment reserves the right to impose additional terms and conditions required to meet our regulations on a continuing basis.Final permit approval is contingent upon the final inspection of the completed system by the Weld County Department of Public Health and Environment. Alex Clemments September 21, 2021 Environmental Health Specialist Date Page 2 of 2 Health Administration Publk Health& Environmental Health Communication, Enwrgvncy Preparedness Vital Records Clinical Services Services Education&Planning &Response kjo:97O34-6410 tele:970-3004.6420 Tele:970-30.1-64x5 Tele:970-304-6470 fele:910304-64141 Fa;.: 970-K4-6412 Sax: 970-304-6;46 Fnn; 973.304-6411 Fox: 9703-04-6452 F.3xL 970-3C-4-6452 Public Health /O � ,`- ,, NORTH WELD COUNTY WATER DISTRICT I. t r 0 P.O. BOX 56 k, k 10‘1 32825 CR 39 '5 __ /° LUCERNE, CO 80646 PHONE:(970)356-3020 • FAX:(970)395-0997 • E-MAIL:water@nwcwd.org ACCOUNT NUMBER NAME AND SERVICE ADDRESS BILLING PERIOD ABCD LANDCO LLC 6537000 40893 CR 252/17/2023-03/21 /2023 AULT, CO 80610 (/-).(/-). / 1116 Water Class P (KGal ) 70 % of 17.000 Acre Feet 3,878 Transferred Water 0 Allocation Adjustment 0 Less YTD Usage 4,438 Remaining Water Allocation -560 Plant Investment Class 70 % of 16.000 Acre Feet 3,650 Less YTD Usage 4,438 Remaining PI Allocation -788 Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Prey. Read Curr. Read Usage Unit Amount Previous Balance 6,916.07 02/17/2023 Payment - -3,705.95 03/14/2023 Payment - -6,916.07 03/21 /2023 Commercial - Industrial 9144 10062 918 kgal 4,075.92 Water Allocation Surcharge P 3,360.00 Plant Investment Surcharge - Tier 1 (788 KGal @ $3.95) P 3,112.60 Current Amount 10,548.52 Total Amount Due - 6,842.57 Hello