Loading...
HomeMy WebLinkAbout720437.tiff_ .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ve CULoRAGO DEPARTMENT OF HEALTH A"' l WATER POLLUTION CONTROL COMMISSION 4210 East it Avenue Denver, Colorado 80220 -- APPLICATION FOR APPROVAL OF LOCATION -- FOR SEWAGE TREATMENT FACILITIES Submit in duplicate Complete only Parts A b B See Instructions Applicant: Interladco, Inc. Address : 515 West 12th Street', Loveland. Colorado 80537 CP.O. .Rnx O4O) A. INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW: 1 . Size and type of treatment facility: 36; raccirc;G4a4T.laemitiis-s)xrny 2. Location of Facility: NE1/4 , Sec. 18, T5N, R67W of the 6th P.M. 3. Name of watercourse into which effluent is discharged: No discharge 4. Location of effluent discharge: Not applicable 5. Describe and give distance downstream of water plant raw water intake nearest this effluent discharge: Not applicable 6. Est.project cost: 5.24,000.00 Est.bid opening date: 7-1-72 Est.compl .date: g-1-72 7. Project layout and design criteria: (Attach separate sheets or report showing entire service area with respect to surrounding areas , habitable buildings , loca- tion of potable water wells with 4 mile, effluent discharge point and topography of area, population to be served. ) 8. Additional information may be required, upon request of the District Engineer and local health department officials . This may include (a) relationship of this facility to area-wide plan, (b) flood plain data, (c) provision for maintenance and operation of the facility including odor control (d) legal status (district , association, municipality) . 9. Have you contacted local planning and building officials or other county officials regarding building permits , zoning matters , special use review permits and other similar matters : Yes Weld Co. Planning Board & Board of County Commissioners No (Name of those contacted) 10. Consulting Engineer: Hogan & Olhausen , P. C. Address : 2300 West Eisenhower Blvd. , Loveland, Colorado Telephone 667-6286 The undersigned applicant agrees to supply information necessary for Review of Plans and Specifications and to secure signatures of the appropriate local government officials prior to submission. (See part B on back of this sheet.) /- 4-18-72 Date Signature of-Applicant Warren A. Stobbe TYPE) NAME President, Interladco, Inc. I' i pthil gi o 720431 B. SIGNATURE OF LOCAL GOVERNMENT OFFICIALS: The undersigned* have reviewed the proposal for the location, construction, operation, and point of effluent discharge of the above-described sewage treatment facility, and RECOMMEND APPROVAL or DIS- APPROVAL in space provided below: RECOMMEND RECOMMEND DATE APPROVAL DISAPPROVAL -71/7/7 /J t Signal r for ocal eal epa tment 41/477-2- DA 1 Signature for Pi nning Commission /7/72 0 � /1-"-e_ZS-1 Signature for Board of Coun y Commissioners Signature for Mayor of City Manager of Municipality *Before plans and specifications will be accepted for review, the applicant must show hereon the action taken on the project by the Local Health Officers, representative of the Planning Commission, representative of the Board of County Commissioners , and the Mayor or City Manager of the municipality that might be affected by the discharge of this waste. C. THE FOLLOWING FOR STATE HEALTH DEPARTMENT USE: I , the undersigned District Engineer, have the following comments : 1 . Is this plant located so that it can serve the needs of the present and/or future logical service area? 7,,,e4 e f � .fente G'i'e.Ser. 'Z` 2. Is the plant located where it is likely to create nuisance problems for existing or now planned development? Qn /y �f nri'etai./7 mamiedine,c/ 3. Has a sufficient amount of suitable land been set aside for expansion? /140 ey4//Siors net42,21fed 4. Has the developer or owner of the facility made provision for adequate funding to buy, maintain, operate, and repair or replace in kind the facility? 5. Are there any community water supply intakes within 5 miles downstream of the effluent discharge points? /1/p c1icandry/e., D. RECOMMENDATIONS: /Q�/r0e4/ — deed azlela filled, snow/44,y ml ana Date: 2778, /2f �rj��i Signature�te47 / iv11.4/ W'-3 (Rev,3-71-20) I % ,. it Hello