Loading...
HomeMy WebLinkAbout20252645.tiff VEROAD RESOURCES September 10,2025 RE:Chemical Disclosure Notification: Operator:Verdad Resources LLC Pad Name:Arnold 02N-64W-24 Pad Location:SESW Sec.24 T2N R64W Interested Party, Pursuant to CO Rev Stat§34-60-132(2024),you are being provided with the attached chemical disclosure for the Arnold 02N-64W-24 Oil and Gas location.The downhole operations for this location commenced on 02/29/2024. For more information related to chemical disclosures,please review ECMC website using the web address below. https://ecmc.colorado.gov/data-maps/chemical-disclosures For more information related to hydraulic fracturing please find the attached information sheet.If you have additional questions,please email inquiries@verdadresources.com. Sincerely, Verdad Resources LLC Enclosures: Chemical Disclosure Hydraulic Fracturing information Sheet Verdad Resources LLC 2025-2645 a9/2-9/25 Chemical State of Colorado Disclosure ti..`, Energy&Carbon Management Commission Rev 1120 Lincoln Street,Suite 801,Denver,CO 80203 5/24 Phone,Suite 801,Denver,CO 80203 *2110 CHEMICAL DISCLOSURE LIST Colorado Revised Statutes(C.R.S.)34-60-132 requires oil and gas operators in Colorado to disclose the chemicals used in downhole operations to certain persons and entities near their downhole operations.Operators report chemical products used in downhole operations to the ECMC on a location-by-location basis.Information provided by Chemical Manufacturers and the oil and gas operator is aggregated by the ECMC into a chemical disclosure list for release to the public.Chemicals are reported on the list alphabetically and include each chemical's Chemical Abstracts Service Number (CAS Number)as assigned by the Chemical Abstracts Service.Pursuant to C.R.S.34-60-132,Operators must provide the chemical disclosure list to the interested parties defined in the law within 30 days after receipt of the chemical disclosure list from the ECMC. Chemical Disclosures Location: 454529 I Arnold 02N-64W-24 County: Weld Operator: 10651 I Verdad Resources LLC Lat/Long: 40.120052/-104.50129 Chemical Name CAS Number 1,2,4-Trimethylbenzene 95-63-6 2-Bromo-2-Nitropropane-1,3-Diol 52-51-7 2-Propenoic Acid,Ammonium Salt 10604-69-0 2-Propenoic Acid,Ammonium Salte(1:1),Polymer With 2-Propenamide 26100-47-0 Acrylamide 79-06-1 Acrylamide Sodium Acrylate Copolymer 25085-02-3 Alcohols,(C10-16),Ethoxylated 68002-97-1 Alcohols,C12-14-Secondary,Ethoxylated 84133-50-6 Alcohols,C12-16,Ethoxylated 68551-12-2 Alcohols,C14-15,Ethoxylated 68951-67-7 Benzene,C10-16 Alkyl Derivatives 68648-87-3 Diolamine 111-42-2 Ethanol 64-17-5 Ethylene Oxide 75-21-8 Fatty Acid,Tall-Oil 61790-12-3 Formaldehyde,Polymer With 2-Methyloxirane,4-NonyLPhenol And Oxirane 63428-92-2 Formaldehyde,Polymer With 4-(1,1-Dimethylethyl)Phenol And 2-Methyloxirane 29316-47-0 Glutaraldehyde 111-30-8 8/19/2025-9:51 AM Page 1 of 2 Chemical Name CAS Number Heavy Aromatic Petroleum Naphtha 64742-94-5 Hydrochloric Acid 7647-01-0 Hydrogenated Tallow Amine 61791-26-2 Hydrotreated Light Petroleum Distillate 64742-47-8 Methanol 67-56-1 Naphthalene 91-20-3 Poly(Oxy-1,2-Ethanediyl),ALPha-(4-NonyLPhenyl)-Omega-Hydroxy-,Branched 127087-87-0 Polyacrylamide 9003-05-8 Polyoxyethylene Monoleate 9004-96-0 Propargyl Alcohol 107-19-7 Quaternary Ammonium Compound 68424-85-1 Sodium Bisulfite 7631-90-5 Sodium Hydroxide 1310-73-2 Sodium Hypochlorite 7681-52-9 Sorbitan,Mono-9-Octadecenoate,(Z) 1338-43-8 Sorbitol Diethoxylated Tetraoleate 61723-83-9 Tall Oil Acid Diethanolamide 68155-20-4 Thiourea-Formaldehyde Copolymer 68527-49-1 Tributyl Tetradecyl Phosphonium Chloride 81741-28-8 Water 7732-18-5 8/19/2025-9:51 AM Page 2 of 2 an open pathway to the wet. This allows the oil migration of fluids associated with oil and gas IMIFSTATE OF and gas to seep from the rock into the pathway, development.After it is determined that the well COLORADO up the well and to the surface for collection.In is capable of producing oil or natural gas, a ,1. Colorado,the targeted formations for hydraulic production casing is set to provide an added OIL& fracturing are often more than 7,000 feet underground, layer of separation between the oil or natural '� and some 5,000 feet below any y gas stream and freshwater aquifer. A well VgAII drinking water aquifers. survey called a cement bond log is performed to GAS ensure the cement is properly sealed around the The process of hydraulic fracturing has been casing.Additionally,the COGCC requires that CONSERVATION COMMISSION used for decades in Colorado, dating to the prior to hydraulic fracturing, the casing be 1970s. Hydraulic fracturing continues to be pressure tested with fluid to the maximum Colorado Department of Natural Resources refined and improved and is now standard for pressure that will ever be applied to the casing. virtually all oil and gas wells in our state,and The well's construction design is reviewed by across much of the country. Hydraulic fracturing the professional engineering staff at the Information on has made it possible to get the oil and gas out of COGCC. Any flaw in the design will be rocks that were not previously considered as corrected prior to issuing the required drilling likely sources for fossil fuels. permit. Hydraulic Fracturing Common questions and answers about Q: What kinds of fluids do operators use to What is hydraulic fracturing? hydraulic fracturing. hydraulically fracture wells? Hydraulic fracturing is the process of creating Q:Can hydraulic fracturing open up pathways A:Approximately 99.5%of the fracturing fluid small cracks,or fractures,in deep,underground for oil and gas to reach ground water zones volume is water and sand. The remaining geological formations to liberate oil or natural where water wells are producing? portion is made up of a variety of chemicals. gas and allow it to flow up the well for capture There are chemical additives used to reduce and use in heating our homes,fueling our cars A: The distance between the oil and gas friction during pumping and prevent corrosion of and providing the electricity we all use for our formation and the water formations is the steel,biocide to kill bacteria in the water and televisions,computers and other devices. substantial.In the case of the Niobrara and the surfactant to promote water flowback.The exact Fox Hills Aquifer in northeast Colorado, for formulation may vary depending on the well and To fracture the formation, fracturing fluids— example,the separation is about 5,000 feet—or the objectives of the specific fracturing mostly water and sand,with a small percentage roughly a mile—of bedrock. treatment. Fracturing chemicals are similar to of chemical additives—are injected down the other industrial chemicals which must be well bore into the formation.The fluid,injected Q: How do you ensure the fracturing fluid, handled properly. For certain chemicals,safe under pressure, causes the rock to fracture including the chemical additives,don't escape work practices, proper site preparation, and along weak areas. the oil and gas wellbore and impact nearby attentive handling are required to ensure that water wells? employees,the public,and the environment are The fluids that create the initial fractures are protected. then mixed with thicker fluids that include sand A:The COGCC requires all wells to be cased and gelatin.These thicker fluids lengthen the with multiple layers of steel and cement to COGCC rules require that operators publicly openings in the rock.When the fractures are isolate fresh water aquifers from the disclose the ingredients and concentrations of complete, and pressure is relieved,the fluids hydrocarbon zone. The steel casing and fracturing chemicals for each well within 60 days flow back up the well where they are captured surrounding layers of cement protect the of completion.That information is required to be and stored for later treatment or disposal. drinking water aquifers that the wellbore posted on the website www.fracfocus.orq,which penetrates.Surface casing is required to extend is searchable by county,operator and well.The As the fluids flow back up,sand remains in the 50 feet below the base of the deepest website also provides information on chemicals fractures and props the rock open,maintaining freshwater aquifer to seal it off from any possible used and their purpose. to several days depending on the number of suspected impacts by the drilling or hydraulic Q: How am these fluids managed on the fracture zones.You will not feel the fracture of fracturing of oil and gas wells. surface? the rock because of its very low energy and depth of the formation. The equipment noise is How do I obtain baseline water samples? A:Large volumes of fluids are maintained on the the most noticeable occurrence during the drill site during the drilling and hydraulic operations. The COGCC provides baseline sampling on a fracturing process.Operators must take great case-by-case basis based on proximity to new care to prevent spills; operators are charged The COGCC has rules that are specific to or existing drilling activity. Please contact the with protecting environmental resources and hydraulic fracturing.For more information on COGCC at 303-894-2100. spills violate state law.The fluids are blended on these rules,visit:http://cogcc.state.co.us site in equipment that adjusts the mix of sand, The Colorado Oil&Gas Association(COGA),an water and chemicals at different stages of the • Rule 205 Inventory chemicals industry trade group,has a voluntary baseline operation.The blended mix is sent to pumping • Rule 205A Chemical disclosure ground water quality sampling program units to raise the pressure and send the fluid • Rule 317 Well casing and cementing; http://www.coga.orq/index.php/BaselineWaterSa down the well. Like spills, operators must Cement bond logs mpling. prevent leaks. In addition to complying with • Rule 317B Setbacks and precautions state regulations,leaks and spills would create near surface watersUnder the COGA program, samples are costly delays,providing additional incentive for and tributaries that collected from two existing groundwater operators to ensure all fittings and connections are sources of public drinking water features,such as wells or springs,within one- are pressure tested with clean water before any • Rule 341 Monitoring pressures during stimulation half mile of the surface location of new oil and operations begin. • Rule 608 Special requirements for coal- gas well pads,or new wells on existing pads. bed methane wells These samples require landowner consent and After the fracturing is completed,fluids return to will be collected before drilling begins.A second the surface as"flowback."These fluids are now • Rules 903&904 Pit permitting,lining, round of sampling will be collected from each considered exploration andproduction waste monitoring,&secondary containment p feature within one to three years after drilling is and must be treated accordingly • Rule 906 Requires COGCC notify 9 Y�in compliance completed. Results of all samples will be with state regulations. Production fluids, CDPHE and the landowner of any spill provided to landowners within three months of including oil and related substances,also rise to that threatens to impact any water of the collecting the sample.The laboratory results will the surface. All of these fluids must be state also be submitted to the COGCC for inclusion in separated and contained in impervious vessels a water quality database that will be available to and waste fluids must either be recycled or Where can I get further information? the public through the COGCC website. properly disposed of under regulatory oversight. The FracFocus website—www.fracfocus.orq— Water well owners can also either sample their contains detailed explanations on how hydraulic own water wells or contract a qualified individual Q: What can neighbors expect to experience fracturing works,how groundwater is protected, to collect samples for baseline testing. Most during the fracture stimulation work? what chemicals are used,and how to find a well analytical laboratories can provide sampling near you. The COGCC has additional along with analytical services. A list of A:After the drilling rig is moved off site,water information on its hydraulic fracturing information laboratories offering these services can be found tanks are brought to the site and water-hauling page at its website: http://cogcc.state.co.us under Laboratories-Analytical or Laboratories- trucks arrive.The day the operation is to begin, Testing in the phone directory. the sand haulers,pump truck,blender and the What is the purpose of baseline water sampling? control van arrive.The equipment will all be The Colorado Department of Public Health and connected together and then connected to the The purpose of baseline water sampling is to Environment also offers analytical laboratory well head with high pressure hoses.After testing collect data before any drilling operations at services. Call 303-692-3090 for additional the equipment,the actual fracture stimulation individual well sites to demonstrate the pre- information. will begin.The operation may take several hours drilling conditions of a water well.This provides http://www.cdphe.state.co.us/Ir/water.htm a reference point for future evaluations of any Hello