HomeMy WebLinkAbout20251170.tiffMEMORANDUM
TO: Diana Aungst, Planning Services
FROM: Melissa J King, PE, CFM - DRE
DATE: December 30, 2024
SUBJECT: COZ24-0008 Conlon
The proposal has been reviewed on behalf of the Weld County Department of Public Works and Department
of Planning Services. Staff comments made during this phase of the application process may not be all-
inclusive, as other issues may arise during the remaining application process.
COMMENTS:
Parcels: 080525200007 Lot B RE -2485; 080524000020.
The project proposes to: Change of Zone from the R-1 (Low Density Residential) Zone District to the A
(Agricultural) Zone District.
ACCESS:
Weld County Development Review has reviewed the application materials related to access.
The southern parcel (080525200007 Lot B RE -2485) has an existing, oil and gas permitted access AP15-
00121) onto CR 66, also known as AA Avenue. Additionally, in the platting of RE -2485 (Rec. Number
2734381), a 30 -foot -wide "common access easement for Lot A and Lot B" was created to allow access onto N
35th Avenue, approximately 1,260 feet south of the intersection of N 35th Avenue and CR 66. Lot A of RE -
2485 obtained an access permit onto N 35th Avenue (AP21-00384) at the location included on the recorded
plat for RE -2485. The access permit included the following language "If and when a proposed change of use
for the access occurs, the access shall come into compliance with all applicable Weld County Code standards
and requirements."
The northern parcel (080524000020) has an existing, industrial permitted access onto CR 66, also known as
AA Avenue (AP15-00121).
Per Sec. 8-14-30, an Access Permit is required for access to Weld County maintained roadways. Please
refer to Chapter 8 of the Weld County Code for more information regarding access.
ROADS AND RIGHT-OF-WAY:
County Road 66, also known as AA Avenue, is a paved road and is designated on the Weld County
Functional Classification Map (Code Ordinance 2017-01) as a collector road, which requires 80 feet of right-
of-way. The applicant shall delineate and label on the site map or plat the future and existing right-of-way
(along with the documents creating the existing right-of-way) and the physical location of the road. If the
right-of-way cannot be verified it shall be dedicated. Pursuant to the definition of setback in the Weld County
Code, Sec. 23-1-90, the required setback is measured from the future right-of-way line. Be aware that
physical roadways may not be centered in the right-of-way. This road is maintained by Weld County.
N 35th Avenue is a paved road and is designated on the Weld County Functional Classification Map (Code
Ordinance 2017-01) as an arterial road, which requires 140 feet of right-of-way. The applicant shall delineate
and label on the site map or plat the future and existing right-of-way (along with the documents creating the
existing right-of-way) and the physical location of the road. If the right-of-way cannot be verified it shall be
dedicated. Pursuant to the definition of setback in the Weld County Code, Sec. 23-1-90, the required setback
is measured from the future right-of-way line. Be aware that physical roadways may not be centered in the
right-of-way. This road is maintained by Weld County.
Per, Sec. 8-13-30.B, a Weld County Right -of -Way Use Permit is required for any project that will be
occupying, constructing or excavating facilities within, and/or encroaching upon, any County rights -of -way or
easement. Right -of -Way Use Permit instructions and application can be found at
https://www.weldgov.com/Government/Departments/Public-Works/Permits
Weld County will not replace overlapping easements located within existing right-of-way or pay to relocate
existing utilities within the County right-of-way.
CONDITIONS OF APPROVAL:
The plat shall be amended to delineate the following:
1. County Road 66, also known as AA Avenue, is a paved road and is designated on the Weld
County Functional Classification Map as a collector road which requires 80 feet of right-of-
way at full buildout. The applicant shall delineate and label on the site map or plat the future
and existing right-of-way (along with the documents creating the existing right-of-way) and
the physical location of the road. All setbacks shall be measured from the edge of right-of-
way. This road is maintained by Weld County. (Development Review)
2. N 35th Avenue is a paved road and is designated on the Weld County Functional
Classification Map as a arterial road which requires 140 feet of right-of-way at full buildout.
The applicant shall delineate and label on the site map or plat the future and existing right-of-
way (along with the documents creating the existing right-of-way) and the physical location of
the road. All setbacks shall be measured from the edge of right-of-way. This road is
maintained by Weld County. (Development Review)
3. Show and label the existing, permitted access points onto CR 66, also known as AA
Avenue, and N 35th Avenue. Include the access types. (Development Review)
DEVELOPMENT STANDARDS (NOTES ON THE PLAT)
1. The property owner or operator shall be responsible for controlling noxious weeds on the site,
pursuant to Chapter 15, Article I and II, of the Weld County Code. (Development Review)
2. Access on the site shall be maintained to mitigate any impacts to the public road including damages
and/or offsite tracking. (Development Review)
3. The historical flow patterns and runoff amounts will be maintained on the site. (Development
Review)
COUNTY
WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT
1555 North 17th Avenue, Greeley, CO 80631 www.weldhealth.org
Memorandum
To: Diana Aungst, Planning Services
From: Lauren Light, Environmental Health Services
Date: December 13, 2024
Re: COZ24-0008 Applicant: Patricia J Conlon
Environmental Health Services has reviewed this proposal requesting a Change of
Zone from R-1 (Low Density Residential) Zone District to (Agricultural) Zone District.
Both parcels have residences and are served by North Weld County Water District and
permitted on -site wastewater treatment systems. Copies of the water bills and OWTS
permits were included in the application. SP -1000062 serves 2781 AA ST and SP -
0900066 serves 2480 N 35th Ave.
We recommend the following appear as notes on the resubdivision plat:
1. Water service may be obtained from North Weld County Water District.
2. The parcels are currently not served by a municipal sanitary sewer system.
Sewage disposal may be by on -site wastewater treatment systems (OWTS)
designed in accordance with the regulations of the Colorado Department of
Public Health and Environment, Water Quality Control Division, and the Weld
County Code in effect at the time of construction, repair, replacement, or
modification of the system.
3. Activity or use on the surface of the ground over any part of the OWTS must be
restricted to that which shall allow the system to function as designed and which
shall not contribute to compaction of the soil or to structural loading detrimental
to the structural integrity or capability of the component to function as designed.
Health Administration
Vital Records
Tele: 970-304-6410
Fax: 970-304-6412
Public Health &
Clinical Services
Tele:970-304-6420
Fax: 970-304-6416
Environmental Health
Services
Tele:970-304-6415
Fax: 970-304-6411
Communication,
Education & Planning
Tele:970-304-6470
Fax: 970-304-6452
Emergency Preparedness
& Response
Tele:970-304-6470
Fax: 970-304-6452
Public Health
Submit by Email
Weld County Referral
November 27, 2024
The Weld County Department of Planning Services has received the following item for review:
Applicant: Patricia J Conlon Case Number: COZ24-0008
Please Reply By: December 25, 2024 Planner: Diana Aungst
Project: Change of Zone from the R-1 (Low Density Residential) Zone District to the A (Agricultural)
Zone District.
Parcel Number: 080525200007-R8284500 Legal: Lot B of RE -2485 part of the E2NW4 Section 25,
T6N, R66W of the 6th P.M., Weld County, Colorado.
Parcel Number: 080524000020-R1340486 Legal: Part of the W2SE4/E2SW4 of Section 25, T6N, R66W
of the 6th P.M., Weld County, Colorado.
Location: East of and adjacent to CR 35 (35th Avenue) and north and south of AA Street (CR 66)
The application is submitted to you for review and recommendation. Any comments or
recommendation you consider relevant to this request would be appreciated. Please reply by the
above listed date so that we may give full consideration to your recommendation. Any response not
received before or on this date may be deemed to be a positive response to the Department of
Planning Services. If you have any further questions regarding the application, please call the
Planner associated with the request. Please note that new information may be added to
applications under review during the review process. If you desire to examine or obtain this
additional information, please call the Department of Planning Services.
1"
We have reviewed the request and find that it does / does not comply with our
Comprehensive Plan because:
We have reviewed the request and find no conflicts with our interests.
See attached letter.
Signature
Abigail Hejmanowski
Date 12/11/2024
Agency City of Greeley Community Develop
Weld County Planning Dept. PO Box 758, Greeley, CO 80632 Tel:(970)-400-6100 Fax:(970)-304-6498
rep e
SENT VIA EMAIL ONLY
December 11, 2024
Diana Aungst
Weld County Planning and Zoning
1555 N 17th Avenue
Greeley, CO 80631
daungst@weld.gov
Re: Weld County Referral COZ24-0008 (REF2024-0044)
Diana,
Thank you for providing the City of Greeley the opportunity to review the above -mentioned project. The subject
site is located within the Greeley's Long Range Expected Growth Area (LREGA), the area in which the
community anticipates annexation and urban development to occur in the future. The Comprehensive Plan
indicates this property as future Urban Reserve areas.
Planning
1. The Greeley Historic Preservation Office would recommend maintaining and continuing use of the
existing buildings and would be happy to serve as a resource for preserving them. Contact
HPO@g reelevgov.com for further information.
Engineering Development Review
2. Engineering does not have any comments to contribute currently.
All code sections are from the Greeley Development Code and from the City of Greeley Design Criteria and
Construction Specifications, Volumes I, H, & III. Sections of the Code or Construction Specifications are shown in
brackets as part of the review comments below.
For additional information on the City Code or the Design Criteria, see the City of Greeley web site at the following
location:
Planning: https: www.municode.comlibrary 'co'greeley'codes municipal code
Comprehensive Plan: https: !greeleygov.com dots' default -source 'community -development ' long-range-
planning'imagine-greeley'imagine greeley comprehensiveplan adopted 02-06-
2018.pdf
Engineering: http: greeleygov.comservices design -criteria -and -construction -specifications
ORIGIN Map: http: gis3.greelevgov.com'Html ORIGIN'?viewer propertyfacts
Please contact me with any questions you may have.
Sincerely,
Abigail Hejmanowski, Planner I
Abigail.Hejmanowski@Greeleygov.com
Community Development -Planning Division . 1100 10th Street, Ste. 202, Greeley, CO 80631 . (970) 350-9780 Fax (970) 350-9800
A City Achieving Community Excellence
SG
COLORADO
Division of Water Resources
Department of Natural Resources
December 24, 2024
Diana Aungst
Weld County Department of Planning Services
Transmission via email: daungst@weldgov.com
Re: Patricia J Conlan
Case No. COZ24-0008
E1/2 SW1 /4 and W1/2 SE 1/4 Section 24, and
Pt. E1/2 NW1 /4 Section 25, T6N, R66W, 6th P.M.
Water Division 1, Water District 3
Dear Ms. Aungst:
We have reviewed the above referenced application for a Change of Zone. The submitted
material does not qualify as a "subdivision" as defined in section 30-28-101(10)(a) of the
Colorado Revised Statutes ("C.R.S."). Therefore, pursuant to the State Engineer's March 4,
2005 and March 11, 2011 memorandums to county planning directors, this office will only
perform a cursory review of the referral information and provide comments regarding the
proposed water supply. The comments will not state an opinion on the adequacy of the
water supply or the ability of the water supply plan to satisfy any County regulations or
requirements, and cannot be used to guarantee the physical availability of water or the
issuance of a well permit.
The application seeks to change the zoning on 233 acres consisting of two properties to
match its historic use of agricultural production. The potable water source for the property
is the North Weld County Water District ("NWCWD"). The applicant provided a copy of water
bills from NWCWD for the period of October 20, 2023 through November 20, 2023,
confirming that water service is presently being provided to the properties. This office
considers the NWCWD to be a reliable water source.
According to the application documents, the irrigated field is irrigated with water from two
wells on the property. The application lists well permit nos. 64254-MH and 554-WCB for the
wells.
I.i".S I.:...ii._i"+.• .... k�:,trii� �'2 I Is�: ._,(•. ;.�.) 'Sf}=f!.s .) 'Iill .� r,(:..i�ti" G�s:1:'cl�,�r.;.()lsxi3cic).u()4� I ��
ii :a'.,.I'c,.i: t.t:•.trir:: I),!rt.I�Irs.:;cc.ilirt:Gr:•:l::i :�:::�I l,llr,rr.'I:r': srrcti:l)rtci:: :�
Conlan December 24, 2024
Case No. COZ24-0008 Page 2 of 2
Permit no. 554-WCB (receipt no. C620554) was issued for a well located in the SEA of
Section 24, Township 6 N, Range 66 W, 6 P.M., for "domestic" uses. The well may continue to
be used for those domestic uses served by the well prior to May 8, 1972, provided such uses
do not exceed the maximums allowed by statute and/or policy. Domestic use is limited by
statute to fire protection, ordinary household use inside not more than three single-family
dwellings, the watering of poultry, domestic animals and livestock on a farm or ranch, and
the irrigation of not more than one acre of home gardens and lawns. The well may not be
used for agricultural purposes.
Permit 34069-MH was a notice of intent to construct up to 8 monitoring holes. Five
monitoring holes were constructed and subsequently repermitted under well permit nos.
336005-336009. The use of these wells is limited to monitoring water levels and/or water
quality sampling. These wells may not be used for agricultural purposes.
Prior to using any well on the property, the applicant must contact this office to determine
the correct permit number or register the well as necessary.
Should you or the applicant have any questions regarding any of the above information,
please contact me at this office at 303-866-3581 ext. 8245 or kathleen.fuller®state.co.us.
Sincerely,
74 -3 -u -v -K -u
Kate Fuller, P.E.
Water Resources Engineer
Ec: Well permit file nos. 336005-336009, 554-WCB
Mark Simpson, Water Commissioner (mark.simpson@state.co.us)
Referral file no. 32612
COLORADO GEOLOGICAL SURVEY
1801 Moly Road
Golden, Colorado 80401
December 5, 2024
Diana Aungst
Weld County Planning
daungst@weld.gov
Subject: COZ24-0008
Weld County, CO; CGS Unique No. WE -25-0018
Dear Diana:
Location:
40.4694, -104.7261
Matthew L. Morgan
State Geologist and
Director
At your request (November 27, 2024), the Colorado Geological Survey has reviewed the COZ24-0008 referral.
I understand the applicant proposes to rezone the current R-1 portion of an overall 232 -acre property to Ag
(Agriculture).
The available referral documents include a Geologic Hazards and Mineral Resources Evaluation, Conlon
Property, E''/z of the SW'/4 and W'/z of the SE'/4 of Section 24, and in the E'/z of the NW'/4 of Section 25, T6N,
R66W, of the 6th PM, Weld County, Colorado (EEC Project No. 1242022, April 2, 2024).
The site is not undermined, does not contain steep slopes, and is outside of FEMA 100 -year flood hazard limits.
CGS agrees with EEC that only small portions of the site are mapped as containing a potential aggregate
resource. No geologic conditions are present that would preclude the proposed rezone from R-1 to Ag.
EEC's report contains a very general description of site geology based on available geologic mapping and
NRCS soil survey data, which is typically valid for only the uppermost five feet below the ground surface.
The site is underlain by eolian (wind -deposited) clay, silt and sand. This soil type is commonly loose, low -
density, low -strength, and moisture -sensitive, exhibiting hydrocompaction (consolidation and settlement under
loading and wetting), and shrink -swell of the clay fraction in response to changes in water content. Thick
columns of low -density deposits can exhibit significant settlement. The surficial soils are underlain at unknown
depth by the Laramie Formation or Pierre Shale, consisting of potentially highly expansive shales and
claystones interbedded with non -expansive sandstones, coal beds and lignites. Shales and claystones can exhibit
large volume changes in response to changes in water content. Expansive shale and claystone layers and lenses
within a few feet of foundation bearing elevations can cause significant structural damage if not identified and
mitigated. Perched water and shallow groundwater may be present or may develop post -construction. Wetland
areas are not suitable for development due to very soft, wet, organic soils. For any future buildings, paved
roads, or other development, a site -specific geotechnical investigation consisting of borings, sampling, lab
testing, analysis and recommendations will be needed.
Thank you for the opportunity to review and comment on this project. If you have questions or require
additional review, please call me at (303) 384-2643, or e-mail carlson@mines.edu.
Sincerely,
Jill Carlson, C.E.G.
Engineering Geologist
WE -25-0018_1 COZ24-0008
2:50 PM, 12/05/2024
Page 1 of 1
Hello