Loading...
HomeMy WebLinkAbout20252908.tiffResolution Approve Application for Supplemental Grant Funds for Construction of Bridge 19/46.5A Replacement Project and Authorize Department of Public Works to Submit Electronically — Colorado Counties, Inc. (CCI) Whereas, the Board of County Commissioners of Weld County, Colorado, pursuant to Colorado statute and the Weld County Home Rule Charter, is vested with the authority of administering the affairs of Weld County, Colorado, and Whereas, the Board has been presented with an Application for Supplemental Grant Funds for the Construction of the Bridge 19/46.5A Replacement Project from the County of Weld, State of Colorado, by and through the Board of County Commissioners of Weld County, on behalf of the Department of Public Works, to Colorado Counties, Inc. (CCI), with further terms and conditions being as stated in said application, and Whereas, after review, the Board deems it advisable to approve said application, a copy of which is attached hereto and incorporated herein by reference. Now, therefore, be it resolved by the Board of County Commissioners of Weld County, Colorado, that the Application for Supplemental Grant Funds for the Construction of the Bridge 19/46.5A Replacement Project from the County of Weld, State of Colorado, by and through the Board of County Commissioners of Weld County, on behalf of the Department of Public Works, to Colorado Counties, Inc. (CCI), be, and hereby is, approved. Be it further resolved by the Board that Mike Bedell, Department of Public Works, be, and hereby is, authorized to electronically submit said application. The Board of County Commissioners of Weld County, Colorado, approved the above and foregoing Resolution, on motion duly made and seconded, by the following vote on the 27th day of October, A.D., 2025: Perry L. Buck, Chair: Aye Scott K. James, Pro-Tem: Aye Jason S. Maxey: Excused Lynette Peppier: Excused Kevin D. Ross: Aye Approved as to Form: Bruce Barker, County Attorney Attest: Esther E. Gesick, Clerk to the Board Cc; p1.1(CH/DN/N8/DD/Ss), AcTCCD(P J) Moslas 2025-2908 EG0083 Cor*vack tD1OOLl BOARD OF COUNTY COMMISSIONERS PASS -AROUND REVIEW TITLE: CCI Application for Supplemental Bridge Grant Funds DEPARTMENT: Public Works DATE: 10/21/2025 PERSONS) REQUESTING: Michael Bedell, Curtis Hall and Don Dunker Brief description of the problem/issue: The annual applications for bridge replacement grant funds through Colorado Counties Inc. (CCI) are due November 7, 2025. Public Works is proposing to apply for supplemental bridge grant funds for Bridge 19/46.5A Replacement Project. Weld County has a previous grant award and associated COOT IGA dated 7/03/19 in the amount of $500,000. The supplemental grant application proposes to add an additional $2,500,000 to the existing amount, for a total requested grant amount of $3,000,000. What options exist for the Board? 1. Approve the submittal of the CCI supplemental grant application. 2. Do not approve the submittal of the CCI supplemental grant application. 3. Discuss alternate options for this annual CCI grant application cycle. Consequences: Approval of the supplemental grant application could result in the County receiving an additional $2,500,000 towards completion of this bridge replacement project. Impacts: Approval of the grant application will help assure completion of the project. Costs (Current Fiscal Year / Ongoing or Subsequent Fiscal Years): The total approved County CIP budget amount for this project is $11,080,000. Recommendation: Public Works staff recommends authorization to submit this supplemental grant application to CCI prior to the application deadline. Support Recommendation Schedule Place on 6OCC Agenda Work Session Other/Comments: Perry L. Buck Scott K. James Jason S. Maxey Lynette Peppier Kevin D. Ross -fry 2025-2908 I 0171 6EiGO3 leo 1\ a -4•4,. _Nee) 8 01 d", irsear Colorado Counties, Inc. 800 Grant Street, Suite 500 Denver, CO 80203 PUBLIC WORKS DEPARTMENT 1111 H STREET P.O. BOX 758 GREELEY, COLORADO 80632 PHONE: (970) 400-3706 October 1, 2025 RE: Narrative for Bridge WEL019.0-046.5A (Supplemental Grant Funding) Bridge WEL019.0-046.5A is on Weld County Road (WCR) 19 and spans the Little Thompson River. The bridge is located approximately 0.1 miles north of WCR 46.5. This bridge is heavily used by agricultural and oil/gas trucks and equipment. WCR 19 is a vital paved link for the area near the communities of Johnstown, Milliken, and rural landowners south of State Highway 60. Traffic counts show an average daily traffic of 3,000 vehicles per day. Replacement of this bridge is our number one priority for this bridge funds application period. The existing bridge is 30 feet wide, 55 feet long (two spans), and was built in 1960. The bridge has major problems with rusted steel substructure elements. The bridge also has previous scour issues from the 2013 flood. The bridge rail and approach guardrails do not meet current AASHTO/CD0T standards. Rehabilitation instead of replacement is not a viable option, nor cost effective, because of the excessive amount of rusting steel and inadequate opening size. The newly designed bridge is 35 feet wide and 233 feet long (two spans). The elevation of the high point of the newly designed bridge is approximately 7 feet higher than the existing bridge. Weld County received notification of a bridge grant award from CCI on 12/21/2018. A CDOT/Weld County IGA was completed on 7/03/2019 and the amount of grant award is $500,000. Subsequently the bridge design plans, ROW plans, and environmental clearances have been completed. Assuming the ongoing ROW/Easements acquisitions can be completed as planned, Weld County intends to advertise this bridge replacement for construction in July of 2026. Since the design kickoff meeting held October 2019 this bridge replacement project has been plagued with multiple unforeseen issues and difficulties, which have led to the project schedule being delayed greatly and the original project budget being exceeded. Following is a brief list of the main issues being dealt with: • Floodplain mapping revisions after the 2013 major flood event caused the elevations of the new bridge to be much higher, and the new bridge to be much longer than the existing bridge. • Multiple utilities and oil/gas easements and facilities have been mapped and determined that relocation is necessary, and the project will have to reimburse these companies for most of the relocation work. • The existing ROW on the west side of the bridge cannot be expanded due to existing utilities restrictions, mainly power transmission, which has led to steel sheet pile retaining wall being incorporated into the design. • A non -compliant landowner located on the east side of the bridge, and their attorney, have caused a schedule delay of several years for negotiations and design revisions, and led to a large cost increase due to inflationary effects. Weld County is proposing to provide most of the funding for this project. The current total project estimate is $11,000,000. The County has previously been awarded a grant , in the amount o' $500,000 (4.5% of project cost)., If approved for the requested supplemental grant funding, the grant award amount would potentially be increased to a total of $3,000,000 (27.3% of project cost). Please contact us if you need any information in addition to the contents of this application. Sincerely, Michael Bedell, P.E. Senior Engineer COLORADO SPECIAL HIGHWAY COMMITTEE Off -System Bridge Program Application Data " Structure Number WEL019.0-046.5A Application Date 10/1/2025 Structure Location Little Thompson River County / Municipality Weld County CDOT Engineering Region Region 4 CDOT Local Agency Coordinator Consulted Prior to Bryce Reeves Application Date Protect type Request type Replacement Supplement Design lT/el completed at time of application Final Design (Shovel Ready - CDOT clearances acquit Work phase to be funded by this grant application Construction Only Estimated total project cost (Design + Construction) $ 11,000,000 Year the total project cost estimate was created 2025 20% minimum local match amount $ 2,200,000 Local overmatch amount $ 5,800,000 Proposed total local match amount $ 8,000,000 Local match commitment documentation Narrative Letter SHC grant amount requested $ 2,500,000 Colorado fiscal years when funding will be required 2026 Anticipated start date Anticipated completion date October -2026 June -2027 Work description Replacement of an existing bridge constructed in 1960 The roadway would be closed during the construction which would likely take 8-9 months Weld County has already hired a qualified design consultant with extensive knowledge of the CDOT standards, and the design is completed Right -Of -Way plans have been completed and the ROW/Easements acquisition process is ongoing Environmental investigations and clearances are completed Some utilities relocations are required , Weld County would bid out the construction to a qualified general contractor Weld County would only use the grant funds for the construction phase Weld County has a previous grant award and associated CDOT IGA dated 7/03/2019 if place, with a grant award amount of $500,000 This Supplemental Grant Application proposes to add an additional $2,500,000 to the existing amount, for a total requested grant amount of $3,000,000 SHC Worksheet 8/2020 For further definition of terms, see the Structure Management Manual Section 5, Off -System Bridge Program a 3 PODI / NHS Related Projects: P. E UNDER PROJECT: FHWA I'F2WLC1 Of DIVISION INIEKESI (POUT)"? ENO ❑ YES \/Veld County Project Number Project Cade R.O.W. Projects: R O.W. Project Description NATIONAL HIGHWAY SYSTEM'S ONO 0 YES P u b I i c \A/orks D rt m t BRO 030-079 ep a e n TABULATION OF LENGTH & DESIGN DATA FEDERAL AID PROJECT NO. BRO CO30-079 SHEET '1ST TABLE FEET BRIDGE NO. WCR19/46.5A SHEER STATION , SUBSET DRAWING NUMBER ROADWAY STRUCTURE LITTLE THOMPSON M P S O N RIVER GENERAL 1-13 G-001 TO HC -013 WELD COUNT„ ROAD 19(WCR19) CONSTRUCTION PROJECT CODE NO. 23137 COVER. LEGEND. M&S, SOW 1-4 G-001 TO 6.004 STA 8-99 GENERAL NOTES 5- 8 0-005 TO G-008 BEGIN ROADWAY CONSTRUCTION TYPICAL SECTIONS 9 TY 009 J -U -B PROJECT 87-19-011 SU11MMARYOFOUANTITES , 10 TS -010 STA 25.20 �` 1 23C TABULATIONS 11 -12 TI3-011 TO TB -012 END ROADWAY CONSTRUCTION HORIZONTAL CONTROL 13 HC -013 - TOTAL 1821 230 - =4' ► - t:GEO METRICS 14-17 GM TO GM TATE HIGHWAY 60 -101 -104 SUi SUMMARY OF PROJECT LENGTH FEET MILES ` - r -r • � UTILITY 18- 23 UT -201 TO UT 208 ROADWAY (NET LENGTH) 1821 0.304 �'' EXISTING UTILITIES 10- 20 UT -201 TO UT -203 MAJOR STRUCTURE no 0.044 PROJECT- _ .. PROPOSED U ILR IES 21 - 23 UT -204 TO UT -206 _ PROJECT ORO%5 LENGTH 1821 0.304 - "E? REMOVALS - 24 - 26 RM-001 TO R1A-303 DESIGN DATA , w �•. - t PLAN 6 PROFILE ?l - 36 PP -401 TO PP -{10 WELD COUNTY ROAD 19 (WCRt 9) •. , jr WCR 19 PLAN & PROFILE 27 -31 PP -401 TO PP -405 — f 4 STORM DRAINAGE 32 - 36 PP -4#1 TO PP -4b5 MAXIMUM RADIUS OF CURVE NrA� GRADING 37 -42 GR-601 TO GR- 06 MAXIMUM GRADE 2 0% •• IROADWAY GRADING PLAN • 37 - 40 GR-601 TO GR-504 r� 4 MAXIMUM DESIGN SPEED 50 MPH - - •-,,� 1 CHANNEL GRADING PLAN 41 -42 GR-b06 TO GR-0a+ _ N RIPRAP 43 - 47 RR -00' TO RR -605 2024 DESIGN TRAFFIC 3,000 VPO 43-41 RR 801 TO RR 602 GLr_AR ZONE DISTANCE (TANGENT) to FEET el .a: 'WRAPLAYOUT WRAP DETAILS 4b - 47 RR -603 TO RR -605 b.M r- - LITTLE TH • = • NE•SAW 48 - 62 SW -701 TO SW -715 FOR INFORMATION ONLY • -• '•- NOTES 48 - 51 SW -701 TO SW -704 -44•-• 1N t�E 1. Gam' -SWMP SWOP - INITIAL 52 - 54 SVV-705 TO SVII-707 �. ...• �. • SYNMP - INTERIM 65 - 57 SW -708 TO SW 710 I ib f- SWMP - FINAL 58 -61 SW -711 TO $W-714 . 4 7 1"t - - ____ SwIMP -DETAIL 62 SW -715 't•- • • 5 WELD COUNTY RD 46 IQ - t► UTILITY OWNER UTILITY CONTACT • ' , +� f% ' r STRUCTURAL 63 - 112 S•801 TO 5-091 .•�. �. '.1:/'? _ BRIDGE 63-97 5-601 To s636 XCEL ENERGY AL ERMER (970-215-2126) AL EWOE R®XCELENERGY.COM * �/ .± r I. RETA1 LNG VMAlL3 98 98 -111 S-961 TO (GAS & ELECTRIC) • CORY THELEN (970-342-3210) CORY.M THELEN®XCELENERGY COM • a •' s. • ,5.874 'ISEMENT SE1 POC ENERGY of IRRIGATION STRUCTURES 5-891 (GAS70IL) TAMMY WATERS (970-3134521) TAMMY.WATERS®PDCE COM - 1 'a`• • 4 SIGNING & STRIPING 113-115 8N-901 TO SN•903 • w s DCP MIDSTREAM LEWIS HAGENLOCK (870.378.6351) LEWS.D.HAGENLOCKAPe6.COM , ' .,r a� TRAFFIC CONTROL 118-12! TC-1001 TO TC-1008 (PHILLIPS 66) MIKE SMITH {870.324.4327) MICHAEL T,SMRH2QP86 COM - , .., _ 'r PHASING PLAN 116 TC-1001 (GAS/UIL) JESSE BIWER (970-502-2127) _ - - '"-. ,• t a DETOUR PLAN 117 TC-1002 CENTURY LINK (LUMEN) ROBERT RULLI (970988.2120) ROBERT RULUOCENTURYLINKCOM - • 4.NTERSECT►ON - DETAILS 118 -123 TC-1003 TO TC-1008 (PHONE R FIBER) GARY CRISPE (303.9951466) GCRISPE®CONGRUEX C(3M •. 55 CROSS SECTIONS 124 -129 x5-' • in TO )(S-110!3 NOBLE ENERGY (CHEVRON CORP ) TJ MANSFIELD (9704331-2343) TJ.MANSFELDOICHEVRON,COM CRAIG MELTON (719-3698823) t. ' % S t r ADDITIONAL PLANS (FOR INFORMATION ONLY( (GAS) -- ROW PLANS (16 SHEETS) O PROJECT LOCATION MAP O) REG/s IF, 500 , • Q •� �. SCALE N FEET ;/V . f oil 06/ 1212025 • �tj (100%) SUBMITTAL west: ..... ••,\G?-_, MAY 2025 0NAl_ Know % S Ai. _s,'''''''' l Call before ass JRL Print Date 6/13/2025 CD CD O O Sheet Revisions Cr e, FINAL WEL'. 9-46.5A BRIDGE IMPROVEMENTS Project No./Code Stole. AS NOTED Dote: C' -Ifni-re-its In,'Imo COVER SHEET No Revisions BRO CO30.079 t 23137 1 111 H Street Greeley. 1HCO 80631 dr— 2609 E. Harmony Road. Suttu 30D CJUB FoA Co4ms, r'A !30528 fJ Mot le 970.377.3602 r -U -B ENGINEERS. INC Revised esrgner KSMITM Structure Drawing Number G-001 - Phone: (970) 400 -3750 COLORADO ,_ - *• Fax: (970) 304-6497 r Gepwrtmort cif T rnnsportarron DetK.SIAITH Numbers , lid• Sheet fve rnber t of 129 !GENERAL Sheet Subset: Subset Sheets: 1 nt 13 U . 0 6 E I vm ' ''t !�� ' r'„' • . lam.- jXccPLAN LEGEND: ' • }� M • ��, fir" ,>� _ -/�� ' _ - - f "i�SL ,' 7 / j ,`.%•, i- t I ry.. 25' 3G TRANSITION / • PROPOSED ASPHALT PER M-606-1 / - ,. BEGIN 2S• 36 TRANSITION \. i/, -I 1 , f. * PER M-6Uf; --�-*`-- -- r- --- -�1� �J f N�- '4' / r iy' I ��''OON PROPOSEDGRAVEL I / ' , _- \ : / / . / / / ..---' 7-7\---- ! -2361 - S-8/1 I _— — PROPOSED SAINCUT LINE -. Y. • \ 1 1 .1 `� 1 U .1. I G.O / .. FOR RETAINING vrnl_ / I — —.*, PROPOSED 'll�i ` -N)tit- - ,• .. ---- FILL �R.•� { .tom _ -._ ; R/t► K7T) - __ , HM� . R��. 5 so.'r' h; re �MEAM _ .._. ._ u' PROPOSED CUT irk I END Si EPER i �' '� i „ .:�: :.::.L.*...�: .I , `BEGIN r `'., ASPHALT PAVEMENT PROPOSED _-,�- i e ,A ` 1' T �w! (. �� I PA. 7' 1 22 15 0.00' R ---" •' d RIGHT or WAY n 3 9 _ - PROPOSED TEMPORARY .. -1 3• a —Ter �' z •� i (• ... II 1 6 i ) < .- O EASEMENT a I 1 2 t +� ,1„:-...,c ! 224 w- I PROPOSED RETAINING WALL Ifl ...; 1 19}00 - `^i Za r! 18}00 j- ,' (.•20400 1 ` r� 1, E •°� _ { ~ . = i• �-� t i c F — PROPOSED DRAINAGE SWALL a- 2 2y \ N' I 1 - WCR 19 ' •CONTROL uNE I I ► • 6 8 f' I< u fI 304+92 i '. 1 I. t . �- KEYED NOTES r - 1 ' PROPOSED -� t. 1 aftriC i END ANCHORAGErO4 ED3 O1 SAWCUT LINE ;COST TO BE IRO:KR TALI _ c �= ..j -R _. �* 7 -•-$EGiN - D ASPHALT PAVEMENT STA - - ;r: S. r :-. B GIN 25 3G TRANSITION 21+81.96, 16.00' R' "' _ BEGIN SLEEPER BEAM SEE DRAWINGS - - 2 PROPOSED GUARD RAIL TYPE 3 W -BEAM 0 1. �. , PER M-606-1 I ---4 5_ `_i -•-� : 1 STA: T£tt46.65, S-801 - S-835' r '-�.,--•• 5 I_____4.____-- -- _ .. •:-• 0.C1�;' 1 \ \ tog,,, _ _.,�_ �- • i . ,. I i' • ail `"` _ y` •.1 / 1 , FOR BRIDGE \ ‘� ; • ,. ` , , TRANSITION a MFLFJIT END ANCHORAGE (FLARED) PER `; t - STRUCTURt.I �� O ♦, u r '' --- DETAIL v. 1 _-I CDOT m-606-1. -14 10 •% -- - .• �j' 7 Q PROPOSED GRAVEL DRNEWAYIACCESSllt _ ! �� ''- - ND 25' :' _ . 3G TRANSITION 4 j SEE DRAWINGS PP TO PP F STORM DRAIN --' • �` ', '�--~ -451 -455 5 O :��� _ PER M-606- 1 5 - !tl INLET AND PIPE PROFILES. I "N �1 Mt "- TRANSITION GUTTER $LOP£ TO END CURB & GUTTER " PROPOSED BITUMINOUS TYPE 6 CURB PER COOT STD, TYPE 2 (SECTION JIB) STA: 18+42.59. 16.02 ? TA 18+3y.12! t / • APPROACH SLAB CURB IN 10 -FEET r ' 65.94' R 1 ' 1 '. \ i -': .; T S A 21 _ +3f- , 4 54 74' 1 P - I PLAN M 60s -t U SEE DRAWINGS S•831 8 S-832 FOR GUARD RAN. TO I 7 BRIDGE RAIL TRANSITION. 4'90 .. mss.. . .'\ 1 8 FIT GUARD RAIL POSTS AROUND INLET 0 - - 4790 i - HP STA: 20+37.44 HP FLEV: 4775.523 PVI SEA: 19+75.00 FM ELEV. 4776.80 K. 96.22 O PROPOSED ASPHALT PAVEMENT SEE DWG, TV -009 PAVEMENT SECTION '8' 1p PROPOSED PENCE PER COOT M-607-1 BARBED WIRE ,tip FENCE Mb POST I LVC: 337.00 4785 NOTES. ' rTiU,, O^ *� p't 1 SEE DRAWING HC -013 FOR HORIZONTAL CONTROL to ABUT1 :.'t l) TYPO IOM ABUT. 3 �'1�•- 2 SEE DRAWING$ GM -101 TO GM -104 FOR aOh +4.•C001 -' —4780 +'e .- art I+i I 1 BRIDGE RML _ 't ARC. 1 a GEOMETRICS 3 SEE DRAWINGS UT -201 TOUT -206 FOR FOR U71U I It 5 , Ly ' use •��'��` 1 ' 4 SEE DRAWINGS TO --- - GR•501 GR-506 FOR GRADING �w ..) ����..���•as�� �..��� N ��• Tr3 PLANS ����.�.� ' 4775 G' - -1.105 5. SEE DRAWINGS S-801 TO 5.835 FOR BRIDGE. PLANS --� —4775 -. 6 SEE DRAWINGS S•861 To 5-871 FOR RETAINING WALL 2.43'% PLANS. 47701 2.1 0% 7 SEE DRAWING SN-901 TO SN-903 FOR SIGNING S STRIPING. ta a COST OF FORMING TO BE --� WINGWALL, TYP. - ._ -4770 SWALES INCLUDED IN WCR PROPOSED 19 GRADE _ _ ; EARTHWORK PAY ITEMS -L .l 4765- OI. TTOM GiBOER ( ---- -- • mi vi - 760 EXISTING GRADE 11Z I APPROXIMATE 50-YR W.S.E - 4767.00' 1 , 1 h _ . EXISTING NEL �E >' _ 1 STORM DRAIN B2 J 4765 Li 4 -• _.- '' PR SLt) - t - -4760 ..42.06.140%.‘‘‘,4 CHANNEL %CHANNEL GRADE PROPOSED CHANNEL � t° REG/s% 1, -_'.� � I =�--•�' RIPRAP �-- (TYP), SEE �T_ f t.! p s, O�.•••..•6s a 755 y I DRAWINGS RR -601 TO ` i, ; T•�y •. - ' FOR 4' - _ —RR-604 RIPRAP 4755 4.----'774• •�, -. - LAYOUT DETAILS 1 NOR' 0 AC 40 811 1 ORD NARY HIGH ATER MARK • 'o 06/12/2025 C / 4/50- • > , 1 4750 VERT 0 5 10 * ��� 17+50 18+00 18+50 I 19+00 19+50 I 20+00 20+50 21 ,00 21+50 22+00 �S SCALE IN FEET �I /� % es •�4.i linos below •, \'/QNA saes Clab bl.youdi� CENTERLINE PROFILE • =...' �L Print Dote: 6/13/2025 Sheet Revisions 1 . , ,Nt, - e , -� _ t 1111 H Sired Greeley16,,, FINAL WEL19-46.5A BRIDGE IMPROVEMENTS PLAN & PROFILE Project No./Code Scute. Ac. NOif') �<,'„•-,,:,.1- Init. =:o Revs;�ns BRO C030-079 le 0 Cap 2809 E. Ha►mony Roaa, Stile 300 Fori Colisns, CO � - 1,r yc II (970) 400-3750 Fax: (970) 304.6497 COLORADO Deparlmeni of T18nsportation ` �' .: , Designer KSMtII Structure I Drawing Number DP_•cr 1 80528 Phone 970.377.3602 ^ `✓ Detci.er. KSMITI- Numbers 1 Ju:d: �^.ecl Number 30 1 4 of 2_ J•U•A ENGINEERS. INC. (n _ _ Sheet •'vubset f'._M• di F'Ri�Fl1 ,1 Subset Sheets 4 of o a 7 RETAINING WALL, REFER TO \ SHEETS S-861 TO S-871\ \ v /• t IA _ • • I ` N'1 i \ t r , \ t ` _ - 230'-0" ( BRG. TO BRC. Ras 4765— —113'-6" BRG. TO rsRG. — — ast - 4766- - ♦ / ( PIERR2 fir- ,�`.:� • 7 -SLEEPER BEAM STA: 18+46.58 • /1EGIN AP47.5 1A: 1$+47.58 111+00 WCR19 CENTERLINE. & PROFILE GRADE UNE ' LAYOUT UNE WCR 19: •,\-STA: 18+69.40 K FACE ABUT. Y FC: 4774.06 STA: 18+6733 1 -4767_ _ -4 765---- -- STA: 194 84.40 FG: 4775.37 I \ I� II rl t I t • ♦ I / ar 1 •' ' / - t 0' / 4 - -` '-47gs` 1 4 t •/' / I , 1 it,":". ----- - 4.166 RETAINING WALL. REFER TO -\ SHEETS S--861 TO S-871 I . \br..- ., / I 20+00 J. I r I I 113. -6" BRG. TO Q BRG. 6 4.0 Y, r ar a P fV NO'52.57.74"W 334.21' 'I jbSj ▪ • • I - -4767_ ' _to — -- -4766 — — • et — — a a ft --4766-- _ _ 3 malS tea u_ I O • - - _ _ - `'-EXPANSION JOINT 4 was vain bdow Call Wore you do r -, --- =4762---''�-' _ -_- --mow _ `r-_ --4760 / ;- - _nom\\\\%\&. c, ABUT -1 in--- — ----...---4759,-__ _ _ _ - • _ le ' _ airlift. -4761, �~ \ /i /'„� r,/i — —-47ca`' . \. \ \%\—_e,/�/.,.. HORZ VERT 0 • BRIDGE LOCATION 50 100 4790- 4780- 12 24 SCALE IN FEET MOM .... a Ia.' la- HP STA: 204-37.44 HP ELEV: 4775.523 PVI STA: 19+ 75.00 PVI ELEV: 4776.80 K: 96.22 LVC: 337.00 PROFILE GRADE 10'-8" WINGWAU. EXPANSION JOINT, TYP. / C BEARII / NG r / - �`_• -_ • - r BRIDGE PLAN o r 233'-4" OUT —TO —OUT SCALE R4 FEET ` 4 �'iv, I 1 I 1 \ \♦ I 1 I I .\ \ \\ '�♦ - �, ,\ 1 ♦ \ \ l\. \t 1, 8. \\ \ \. I 1 \ . \ \ / I I a -4 75s • m 1,1 END APPROACH SUB STA: 21+21.21 al EPER BENA STA: 21+22.21 K FACE A8U- - STA: 21 +01.06 STA: 20+99.40 F3: 4775.32 CE ABUT 3 a � BEARING , - _ -�_ 35'-0" OUT -TO -OUT EXPANSION JOINT a --ft -- I Vitf- CDOT TYPE 10MASH BRIDGE RAIL. TYP. ••• LIMITS OF STRUCTURAL CONCRETE COATING IS "ALMOND TAN" COLOR OR APPROVED EQUAL. 115.-0" c. ABUT. TO Q PIER 115'-0" Q PIER TO Q. ABUT. 113' - 6" BRG. TO ( BRG. c, ABUT. 1 c BRG. 113'-6" c.BRC. TO BRG. 1' -6" TYP. IL CDOT TYPE t OMASH BRG. TYP. PIER 2 BRIDGE RAIL ABUT. 3 _ c BRG. • 10'-8" WINGWALL 4'-O" SHLDR 12'-0" LANE WCR19 12'-0" LANE 4'-0" SHLDR CONC. DECK (SEE S-824) 2X 3" HMA 2X -4765N \• \ 1'-6' IL • _ 1 1 i (6) 54"D x 66"W PRESTRESSED BOX GIRDERS 3'-7M" •2'-0" BENCH "RIPRAP TO TAPER TO 3'-0" THICK. 2'-0" MIN. AT BENCH. TOP OF WINCWALL m TOP OF DECK 4770- 4760 4750 - 4740-t 18+00 ABUT. LIMIT TOP OF RIP RAP & FILL (BEYOND). TYP. MIN 2 25\ FREEBOARD 1 LOW CHORD EL. 4769.3 3' • I 18+50 100 YR. SCOUR - PIER 100 YR. SCOUR 4723.9' (N.T.S.) ABUT. 500 YR. SCOUR UMIT va 4745.4' LIMIT - 4707.7' (N.T.S.) PROPOSED - GRADE 19+00 APPROXIMATE 50-YR W.S.E - 4767.00' BOTTOM OF GIRDER ' I 19+50 5 SPACES 0 5'-6311` - 27'-934" 3'-7, LOW CHORD I CHANNEL GRADE EL. 4769.96' I 4'-O" DUI. COLUMN 72 DIA. DRILLED CAISSON 20+00 20+50 PIER 500 YR. SCOUR LIMIT = 4741.6- ELEVATION (AT HORIZ CONTROL UNE) • • WINGWALL. RETAINING WALL NOT SHOWN. TYP. 30" DIA. DRILLED CAISSON, TYP. I r 4740 21+00 21+50 22+00 -�\ ABUT. 100 YR. SCOUR 18" (TYPE M) RIPRAP, 3' LIMIT = 4731.0' (N.T.S.) THICK WITH CEOTEX 401 `"- ABUT. 500 YR. SCOUR FILTER FABRIC OR LIMIT - 4722.8' (N.T.S.) APPROVED EQUAL., TYP. TYPICAL SECTION :LOOKING AHEAD STATION) EXISTING GRACE -4790 -- 4780 - 4770 - 4760 - 4750 .•* NOTE: REFER TO GEOTECHNICAL REPORT ENTITLED: "GEOTECHNICAL ENGINEERING REPORT," PROJECT NO. 21195074. PREPARED BY TERRACON CONSULTANTS, INC.. DATED JANUARY 16. 2020. FOR PAVEMENT BORES AND GEOTECHNiCA- INFORMATION. HORZ 0 20 40 VERT 0 20 4C SCALE IN FEET ADvERTtSEMENT SET Project No./Code Print Dote 6/13/2025 Scale: AS NOTED CakEi 1114 ENGtNEERS. 2809 E. Harmony Road. Sidle 300 Fon Collins, CO 80528 Phone. 9 /0.3/7.3802 O O C� Sheet Revisions Dote. Comments Init. 11 t t H Streel Greeley, CO 80631 Phone: (970) 400.3750 Fax (970) 304-6497 a COLORADO Department of Transportation FINAL No Revisions: WEL19-46.5A BRIDGE IMPROVEMENTS GENERAL LAYOUT & TYP. SECTION 8RO C030-079 Revised: Desicner: ACUKURS (Structure Void: Detoiler: KSMITH 1 NJrnbers WE:19-46.5A Crowing Number S-802 Sheet Subset: STRl1C.TURAlISubscl Sheets: 2 of 50 Sheet NL.mber 64 0I 129 SPECIAL BRIDGE FUND -- BRIDGE PROJECT COST ESTIMATE `Structure Number WEL019 0-046 5A Municipality/County Weld Pnonty # Engineering Preliminary Engmeenng Design Engmeenng Construction Engineering Project Engmeenng Final Inspection TOTAL ENGINEERING COSTS Labor - Materials - Equipment Mobilization Site Preparation Excavation Abutments/Piers/Piling Structure/Deck/Guard Rail Approaches Pavement Average Daily Traffic (ADT) 3,000 100,000 1,000,000 500,000 90,000 10,000 $ 600,000 $ 600,000 $ 700,000 $ 2,500,000 $ 2,500,000 $ 700,000 $ 700,000 TOTAL LABOR - MATERIALS - EQUIPMENT,COSTS Contingencies and Utilities Relocation TOTAL PROJECT COSTS Design/Engineering Start Date (mo/yr) Date of Bid Opening (mo/yr) Complete 9/2026 $ $ $ 1,700,000 8,300,000 1,000,000 11,000,000 Construction Start Date (mo/yr) 10/2026 Construction Completion Date (mo/yr) 6/2027 Estimate Prepared by Michael Bedell, P E Phone (970) 400-3706 Title Sr Engineer Date 10/01/25 Approved by Don Dunker, P E Phone (970) 400-3749 Title County Engineer Date 10/01/25 rfr- - f tel ♦f a -a ;r Scale: 1:24,000 (1" = 2,000') 0 O Far J -4 F`R17 Bridge 19/46.5 Vicinity Map r Data layers that appear on this map may or may not be accurate, current, or otherwise reliable. i Bridge 19/46.5A A Notes: ,st ores Street Park Florence Park Moue tam view Park MMiItikG t Fitnoss Pa''k T CR 46. 10/1/2025 10:55:19 AM i 46 11, DISCLAIMER: This product has been developed solely for internal use only by Weld County. The OS database, applications, and data in the product is subject to constant change and the accuracy and completeness cannot be and is not guaranteed. The designation of lots or parcels or land uses in the database does not imply that the lots or parcels were legally created or that the land uses comply with applicable State or Local law. UNDER NO CIRCUMSTANCE SHALL ANY PART THE PRODUCT BE USED FOR FINAL DESIGN PURPOSES. WELD COUNTY MAKES NO WARRANTIES OR GUARANTEES, EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS, ACCURACY, OR CORRECTNESS OF SUCH PRODUCT, NOR ACCEPTS ANY LIABILITY, ARISING FROM ANY INCORRECT, INCOMPLETE OR MISLEADING INFORMATION CONTAINED THEREIN. Scale: 1:24,000 (1" = 2,000') Bridge 19/46.5 Vicinity Map Data layers that appear on this map may or may not be accurate, current, or otherwise reliable. Bridge 19/46.5A A Notes: 10/1/2025 10:54:17 AM DISCLAIMER: This product has been developed solely for internal use only by Weld County. The GIS database, applications, and data in the product is subject to constant change and the accuracy and completeness cannot be and is not guaranteed. The designation of lots or parcels or land uses in the database does not imply that the lots or parcels were legally created or that the land uses comply with applicable State or Local law. UNDER NO CIRCUMSTANCE SHALL ANY PART THE PRODUCT BE USED FOR FINAL DESIGN PURPOSES. WELD COUNTY MAKES NO WARRANTIES OR GUARANTEES, EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS, ACCURACY, OR CORRECTNESS OF SUCH PRODUCT, NOR ACCEPTS ANY LIABILITY, ARISING FROM ANY INCORRECT, INCOMPLETE OR MISLEADING INFORMATION CONTAINED THEREIN. COLORADO Department of Transportation WEL019.0- 046.5A Bridge, SSM - Steel Stringer, Metal Plank Floor Routine Final Report INSPECTION DATE 05/14/2024 INSPECTION ORGANIZATION Alfred Benesch & Company Team Member (1E17): Rachel Spicer Team Leader (1E04): Justin Dietrick Signed on: Not Available Signed by: Not Available Page 1 of 25 ‘C) SI&A Bridge Structure Inspection and Inventory Report Inspection Date: 05/14/2024 Structure Key: WEL019.0-046.5A AP01A - Approach Alignment 72 8 - Meets Desirable AP02A - Waterway Adequacy 71 6 - Equals Min Criteria AP04A - Scour Documentation Yes AP06 - Monitoring Comment AP07 - Monitoring Trigger AP08 - Closure Trigger AP09 - Mobilize Trigger AP10 - Scour Watch 113M No AP11 - Sufficiency Rating 137SR 87 AP12 - NBI Rating Status 0 - Not deficient AP13 - Structural Evaluation 67 5 - Exceeds Min Tolerable AP14 - Deck Geometry Rating 68 AP15 - Underclearance Rating 69 CL04A - Historical 37 N - Not applicable 5 - Not eligible for National Register of Historic Places C01 - Deck Rating 58 CL05A - Toll 20 7 - Good 3 - On free road C02 - Superstructure Rating 59 CL07 - FHWA Bridge Risk 6 - Satisfactory Low C03 - Substructure Rating 60 CL09 - FHWA UW Risk 5 - Fair High C04 - Culvert Rating 62 CL13 - FHWA Load Rating Risk N - Not applicable Low C09A - Channel and Channel Protection 61 CL14 - BTE Eligibility 5 - Bank Protection Eroded Not applicable C11A - Scour Rating 113 CL15 - Federal Submission USERKEY2 5 - Stable within MAJOR VEHICULAR C12 - Overall Condition CL16 - Structure Class USERKEY3 Fair Bridge C13 - Lowest Condition Rating CL17 - Structure Status 5 3 - Active CL01 - Owner 22 CL18 - Responsible Party 02 - County Highway Agency CL02 - Maintenance Responsibility 21 CL19 - Maintenance Patrol 123 02 - County Highway Agency 0 CL03A - Federal or Tribal Land Access 105 CL20 - Parallel Structure Key 8P 4 - Min Tolerable 0 - Not applicable Page 2 of 25 CL21 - Parallel Structure 101 No parallel structure exists. F01A - Feature Type 42A G06 - Curb To Curb 51 H05A - STRAHNET Designation 100 30.2 0 - Non STRAHNET route 1 - Highway 0 F01 B - Feature Type 42B 5 - Waterway 0 F02A - Feature Location 5A 1 - Route carried on the structure 19 G07 - Left Curb Or Sidewalk 50A G08 - Right Curb Or Sidewalk 50B G09 - Approach Roadway Width 32 H06A - LRS Route 13A 123-0-2013 00 H06B - Subroute Number 13B H07 - LRS Mile Point 11 23.999 1.622 F03 - Travelway Name G10 - Median 33 0 - No median 2 F03A - Feature Name 6A G11 - Skew 34 Little Thompson River 0 0 F03B - Feature Name 7 G16 - Federal Deck Area County Road 19 H08A - Lanes On Route 28A H08B - Lanes Under Structure 28B H09 - AADT 29 1654 224 G01A - Qualified Measurement 112 G17 - Asphalt Thickness 66T Yes 6 81 G02 - Total Length 49 G19 - Structure Flared 35 54.8 No 36 G03 - Maximum Span 48 H01A - Functional Classification 26 26.801 G04 - Minimum Span H10 - AADTT H10A - AADTT Percent 109 H11 - Year of AADT 30 19 - Local 2023 H03 - NHS 104 H12 - Maximum Vertical Clearance 10 0 -Not on NHS 99 G05 - Out To Out 52 H04A - National Highway Freight Network 110 H12A - Height Restriction 30.2 0 - Route not on national network for trucks Page 3 of 25 H13 - Minimum Vertical Clearance 54B N/A H23 - Year of Future ADT 115 IE05 - Current Inspection Interval 91 2043 24 H13A - Vertical Clearance Reference Feature H34A - Speed Limit 54A 0 Feature not a highway or railroad H13S - Minimum Vertical Clearance Over 53 H34B - Speed Limit in Front 100.000 0 H14 - Minimum Horizontal Clearance, Left 56 ID01 - Structure Number 8 0 WEL019.0-046.5A H15 - Minimum Horizontal Clearance, Right 55B ID01A - Structure Key 8A 0 WEL019.0-046.5A H15A - Lateral Clearance Reference Feature ID02 - Structure Name 8B 55A 19.0/46.5A Feature not a highway or railroad H16A - Maximum Usable Surface Width 47 ID03 - Replaces 8R 30.2 H16B - Maximum Usable Surface Width in Front ID04 - Replaced with 8RR lE06 - Inspection Due Date 2026-05-14 IE06A - Current Target Date Userkey4 2024-05-15 IE06C - Trip Even IE06C - Trip Odd IE08 - QC Date IE09 - QA Date IE10 - Inspection Finalized 0 2024-08-20 H17 - Detour 19 1.99957 0 H19 - Legacy Milepoint H21 - Base Highway Network 12 0 - Not on the Base Network H22 - Future ADT 114 318 IE01 - Inspection Type IE12 - Inspection Equipment Routine 0 IE02 - Inspection Field Start lE13 - Special Equipment 133 2024-05-14 0 - Not Applicable lE03 - Inspection Date 90 lE15 - Field End Date 2024-05-14 05/14/24 10:45 AM IE04 - Team Leader IE16 - Weather Justin Dietrick 78 Degrees, Partly Cloudy, Calm Page 4 of 25 IE17 - Team Member IR09 - LiDAR Required L09 - Border Percent Responsible 98B Rachel Spicer 0 lE18 - Inspection Team Alfred Benesch & Company No IE19 - Bat Present IE20 - Report Due Date 2024-08-14 • IE21 - Inspection Status L01 - State 1 L11 - Location Description 9 08 - Colorado 0.1 Mi N of Co Rd 46.5 L01 A - Zone L12 - MPO North 2 - North Front Range L02 - County 3 L13 - TPR 2T 123 - Weld 03 - North Front Range L03 - City/Town 4 L18 - Functional Location Final 00000 - Non City No IR01 - NSTM Required 92AA IR02 - Fatigue Details ■ IR03 - UW Required 92BA No ■ IR03A - UW Category ■ IR05 - Pin Required 92CA ▪ IR06 - Special Required L04 - District 2 N01 - Navigable Waterway 38 41 0 - No navigation control on waterway (permit not required) L05 - Latitude 16 N02 - Navigation Minimum Vertical Clearance 39 40.328914 0 L05A - Latitude End N05 - Navigation Channel Minimum Horizontal Clearance 40 0 L06 - Longitude 17 N06 - Foundation Protection 111 -104.886772 No 0 IR07 - Inspection Program USERKEY1 LO6A - Longitude End L07 - Border Structure 99 L08 - Border State 98A RH03 - Structure Rail Type 125A Rail Type AA RH04 - Structure Rail Modified 125B 2 - Modified not up to standards Off System 34 RH05 - Height of Rail 36H Page 5 of 25 RH06 - Structure Rail 36A 0 - Inspected feature does not meet currently acceptable standards or a safety feature is required and none is provided. RH07 - Transition 36B 0 - Inspected feature does not meet currently acceptable standards or a safety feature is required and none is provided. RH08 - Approach Rail 36C 0 - Inspected feature does not meet currently acceptable standards or a safety feature is required and none is provided. 2 0 SP02A - Number Of Spans 45 SP02B - Number Of Approach Spans 46 SP04A - Main Material 43A 3 - Steel RH09 - End Treatment 36D SP04B - Approach Span Material 44A 0 - Inspected feature does not meet currently acceptable standards or a safety feature is required and none is provided. 0 - Other RR02 - Railroad Minimum Vertical Clearance SP06A - Main Span Design 43B 54B 02 - Stringer/Multi-beam or Girder RT02 - Route Number 5D SP06B - Approach Span Design 44B 00000 SP20 - Expansion Device Type 124 O - No expansion device 304/354, 305/355 W01 - Year Built 27 1960 1 00 - Other 0 RT03A - Route Direction 102 SP09A - Deck Material and Type 107 2 - 2 -way traffic 6 - Corrugated Steel RT04 - Route Type 5B SP10A - Wearing Surface 108A 4 - County 6 - Bituminous W02 - Year Work Performed 106 W03A - Work Performed 75A W04 - Work Done By 75B W05 - Length Of Improvement 76 W06 - Bridge Improvement Cost W07 - Roadway Improvement Cost RT05 - Service Type 5C SP11A - Membrane 108B W08 - Total Project Cost 1 - Mainline 0 - None RT06A - Directional Suffix 5E SP12A - Deck Reinforcing Protection 108C W09 - Year of Improvement Cost Estimate 0 - N/A 0 - None RT07 - Primary Routelog user_rway_key04 SP14 - Structure Type 120A W10 - Original Construction Project Number 1 SSM - Steel Stringer, Metal Plank Floor SB06 - Foundation Type 131 1 - Steel, timber, or concrete piles SP15 - Construction Type 120B W11 - Original Construction Subaccount Number Page 6 of 25 Structure Inspection and Inventory Report Inspection Date: 05/14/2024 a � SI&A Notes Structure Key: WEL019.0-046.5A ID05 - Owner Transfer Note user_brdg_key07 IE11 - Inspection Note Date: 05/14/2024 Time: 4:45 PM Temp: 78 F Weather: Partly cloudy Inspectors: JMD/RMS IE11 A - Schedule Note IE14 - Special Access Note L14 - Structure Note Inventory route is south to north West side is upstream Superstructure is named Beam A through Q from west to east Substructure is numbered 1 through 3 from south to north 05/04/2022 - Bridge condition changed from Poor to Fair. Page 7 of 25 r-�tepA Structure Inspection and Inventory Report WI Load Ratings Load Rating Date: 05/07/2024 .Posting. tatus ■ PS01 - Load Posting Status 41 A - No restriction ■ PS01 B - Posting - SHV Trucks ■ PS01A - Posting - CO Legal Trucks ■ PS01C - Posting - EV Trucks Inspection Date: 05/14/2024 Structure Key: WEL019.0-046.5A ■ PS01 D - Temporary Structure No Load Ratings (LR) ■ LR01 - Design Load 31 ■ LR04B - Inventory Rating Method 65 5-HS20 1 -LF ■ LR02 - Design Method LFD ■ LR03 - Load Rating Date 2024-05-08 ■ LR04A - Operating Rating Method 63 1 - LF • LR09 - BrR Structure Number • LR10 - BrR Bid Number ■ LR11 - Plans Available No ■ LR12 - Overload Critical Structure No ■ LR13 - Within 1 Mile No aluation and Postings (EP) .:. ■ EP05 - Posting 70 5 - Equal to or above legal loads ■ EP06 - Load Rating Organization San Engineering - RSH ■ EP07 - Load Rater Name Kendall Posey ■ EP08 - Load Rater Initials KSP ■ EP13 - Rating Calculations Complete ■ EP21 - BrR Rating Analysis • EP14 - Rating Package Complete ■ EP22 - BrR Rating System Based Yes Yes • EP15 - Entire Structure Rated ■ EP23 - Rating Asphalt Thickness Yes 6 • EP16 - Rating Input Files Archived ■ EP24 - Girder Operating Rating Page 8 of 25 ■ EP09 - Checker Name John Migliaccio ■ EP10 - Checker Initials JJM • EP11 - Rating Package Review Date • EP12 - Rating Package Reviewer EP01 Load Configuration HS20 Inventory (Tons) HS20 Operating (Tons) Type 3 Type 3S2 Type 3-2 Type SU4 Type SU5 Type SU6 Type SU7 NRL (40T) EV2 (28.75T) EV3 (43T) • EP17 - Rating Output Files Archived • EP18 - Rating Assigned To • EP19 - Rating Software Used • EP25 - Overload Color Code • EP26 - Overload Color Code Live Load • EP27 - Operating Controlling Member 1 - BrR (non-NSG) I - Interior girder ■ EP20 - BrR Rating Runs ■ EP28 - Rating Comment EP02 Load Rating 29.2 48.8 44.4 68 70 43.8 46.2 47.8 52.4 53.3 47.9 45.7 6" asphalt above corrugations on 4 1/4"x12"x7 ga. corrugated metal plank deck. Galvanized W -Beam rail on W8x18 posts @ 6'-3" spacing. (17) S15x42.9 oirders a varied snacino on North Snan (1 61 l S15x42 Page 9 of 25 Structure Inspection and Inventory Report Elements Inspection Date: 05/14/2024 Structure Key: WEL019.0-046.5A Element/Defect Unit Total Qty CS1 107 - Steel Open Girder/Beam feet 904 1000 - Corrosion 7000 - Damage 0 CS4 773 130 1 903 0 773 130 0 1 0 0 0 1 S15x42.9 beams, (16) in Span 1 and (17) in Span 2. Highwater debris from September 2013 flooding lodged between beams. Rail posts are welded to exterior webs. Lateral C -channel bracing at midspan, longitudinally welded to bottom flanges. Lateral C -channel bracing at supports, welded to top flange. Lateral bracing at Abutment 3 n Bays E, H, and M is not secure; Beam Q east stiffener is not secure. Beams have R1 corrosion throughout (773 CS2 1000 used, 904 CS2 total). Exterior beam flanges and isolated interior beam bottom flanges have R2 corrosion with 5% section loss (130 CS3 1000). Beam Q web 20 feet from Abutment 3 at previous rail post connection has a 5 inch vertical x 1.5 inch horizontal tear (1 CS4 7000). CS4 defect has been reviewed by Benesch Program Engineer and affects the element or structure strength and/or serviceability. Bridge owner was notified of Essential Repair Finding on 06/21/2024. 515 - Steel Protective Coating sq feet 110 Exterior beams are painted red. Failed at isolated areas of corrosion. 219 - Steel Abutment feet 60 1000 - Corrosion 0 0 0 110 0 0 54 6 60 0 0 54 6 Page 10 of 25 Vertical 2 inch x 17 inch sheet pile backwall. 4 feet additional abutment height exposed due to September 2013 flooding. Abutment 1 has R2 to R3 corrosion throughout (30 CS3 1000). Abutment 3 has R3 to R4 corrosion throughout (24 CS3 1000 used, 30 CS3 total). Abutment 3 between Piles 3A and 3C has perforations up to 0.75 inch x 4 inch for 6 feet (6 CS4 1000). CS4 defect has been reviewed by Benesch Program Engineer and does not affect the element or structure strength and/or serviceability. Quantity left in CS4 as a flag for next inspector to determine if defect has deteriorated more and will require another review. 515 - Steel Protective Coating sq feet 60 Painted red. Failed at isolated areas of corrosion. 225 - Steel Pile each 18 1000 - Corrosion 0 0 0 60 0 1 17 0 18 0 1 17 0 (6) 8 inch H -piles (original flange and web thickness = 0.445 inch) per abutment and Pier 2. 4 foot of additional pile lengths exposed at Pier 2 and Abutment 3 due to September 2013 flooding. Piles are unbraced between 8 and 9.5 feet high. Abutment piles do not have cross bracing. All piles at lower 1 to 3 feet have R2 to R3 corrosion, except Pile 3F has R1 corrosion (1 CS2, 17 CS3 1000). Pile flanges have knife edging with 0.12 inch minimum tip thickness (73% section loss), measured at Pile 3E. Abutment 1 piles have 5% to 15% average section loss with average minimum 0.36 inch flange thickness and 0.41 inch web thickness, measured at Pile 1E. Piles 3A -3E have 3% to 23% average section loss with average minimum 0.31 inch flange thickness and 0.41 inch web thickness, measured at Pile 3A. Pier 2 piles were reported to have 31% to 36% average section remaining; could not verify during 2022 and 2024 inspections due to water depth. 515 - Steel Protective Coating sq feet 18 Painted red. Failed at areas of corrosion. 231 - Steel Pier Cap feet 91 0 0 0 83 0 8 0 Page 11 of 25 1000 - Corrosion 91 0 83 8 0 8 inch H -caps. Highwater debris on caps due to September 2013 flooding. Caps have R1 corrosion throughout (83 CS2 1000 used, 91 CS2 total). Pier 2 cap above Pile 2B has R2 corrosion for 8 feet (8 CS3 10000). 515 - Steel Protective Coating sq feet 91 Painted red. Failed at areas of corrosion. 260 - Slope Prot/Berms each 2 0 0 0 0 0 91 0 2 Natural berms previously at both abutments were washed away during September 2013 flooding. Sparse large rocks in front of both abutments. 30 - Steel Deck Corrugated/Orthotropic/Etc. sq feet 1655 1000 - Corrosion 1270 165 220 0 385 0 165 220 0 4 1/4 inch x 12 inch x 7 gage painted corrugated metal deck; installed between 2012 and 2014 inspections. Approximately one third of the deck could not be inspected due to highwater debris lodged between beams. Exterior bays have R2 corrosion throughout (220 CS3 1000). 10% of remaining bays have R1 corrosion (165 CS2 1000). 510 - Wearing Surfaces sq feet 1655 6 inches of asphalt above corrugations. New asphalt prior to 2016 inspection. Each corner of roadway has erosion hole up to 4 inch diameter. 515 - Steel Protective Coating sq feet 1655 Painted. Failed at isolated areas of corrosion. 1655 0 1270 0 0 0 0 385 Page 12 of 25 322 - Approach Roadway each 1 Well aligned, no speed reduction required. Asphalt at ends of structure have transverse cracks up to 0.50 inch wide. 326 - Wingwalls each 4 (1) 8 inch painted steel H -pile and cap with painted steel sheet pile backwall. 1 0 0 4 0 0 0 All wingwalls have R2 to R3 corrosion (4 CS2). South wingwalls at ends are leaning out 6 inches and are slightly bulged beneath cap (2 CS2 overlap). Southwest wingwall H -pile weld at Abutment 1 cap is separated up to 1.75 inch and pushed toward channel up to 2 inches. Northwest backwall is bulging out up to 2 inches and H -pile is leaning 6 inches towards channel (1 CS2 overlap). 330 - Metal Bridge Railing feet 110 1000 - Corrosion 92 18 0 0 18 0 18 0 0 Galvanized W -beam rails with 6 inch blockouts on 8 inch steel wide flange posts; boxing glove end treatments at west, fishtail treatments at east. East rail at north end ends before bridge. All posts have R1 corrosion (18 CS2 1000). 515 - Steel Protective Coating sq feet 110 Galvanized W -beam on tan/red painted posts. Paint failed at areas of corrosion. 501 - Channel/Bank each 1 92 0 1 0 0 18 0 0 Page 13 of 25 Flow is west to east; water was 18 inches deep at time of inspection. Natural, meandering, sandy/silt streambed with unregulated flows through a wide, flat prairie valley floor. Bend in channel at southwest is cutting to south. Flow is primarily through Span 1. Poor channel alignment. Heavy channel aggradation prior to 2016 inspection. Silt bar built up in Span 2. Debris dam downstream of bridge causes water to pond under bridge. Large household debris 25-30 feet downstream slightly directs water to north bank. Abutment 1 berm has local scour holes around piles up to 2 foot deep. Bank erosion due to September 2013 flooding at northwest bank adjacent to northwest wingwall has been repaired. Slight chance of overtopping bridge and both approaches; overtopped during September 2013 flooding. 600 - General Notes none 1 No approach rails or object markers at all corners. Delineator decals on rail ends at northeast and southeast corners. Southeast quadrant has irrigation ditch and 4 foot CMP near wingwall. Power lines run along both right-of-way. 1 0 0 0 Page 14 of 25 a. Structure Inspection and Inventory Report is _ ;:e.en Photos Inspection Date: 05/14/2024 Structure Key: WEL019.0-046.5A 30 - Steel Deck Corrugated/Orthotropic/Etc. 1000 - Corrosion WEL019.0-046.5A Exterior bay deck joint corrosion, typical 5/14/2024 12:00:00 AM 510 - Wearing Surfaces WEL019.0-046.5A Northeast corner erosion hole 5/14/2024 12:00:00 AM • :. la 4 ♦.'. ., r. • • 4 .� . ♦ .ir . v• 'r .* '' .! . _' ; h,r. . • � .-::..c:'' . t. -•::••••;• •:'• •.', N: .•. ,- • •f WEL019.0-046.5A Northwest corner erosion hole 5/14/2024 12:00:00 AM Page 15 of 25 stei L' t J J't' • '• p,11/4 rr: - ' .c. it r i kt Atillttar a.Ill•• -<•, • WEL019.0-046.5A Southeast corner erosion hole 5/14/2024 12:00:00 AM 107 - Steel Open Girder/Beam 7000 - Damage WEL019.0-046.5A Beam 2Q web has tear at old post connection 5/14/2024 12:00:00 AM WEL019.0-046.5A Southwest corner erosion hole 5/14/2024 12:00:00 AM 219 - Steel Abutment Page 16 of 25 WEL019.0-046.5A Abutment 1 general 5/14/2024 12:00:00 AM WEL019.0-046.5A Abutment 3 general 5/14/2024 12:00:00 AM 225 *Steel Pile 1000 - Corrosion WEL019.0-046.5A Abutment 3 pile and backwall R2 -R3 corrosion, typical 5/14/2024 12:00:00 AM 231 - Steel Pier Cap 1000 - Corrosion Page 17 of 25 WEL019.0-046.5A Pier 2 cap south face at Pile 2B corrosion WEL019.0-046.5A Pier 2 cap south face at Pile 2B corrosion (close up) 5/14/2024 12:00:00 AM 5/14/2024 12:00:00 AM 326 - Wingwalls WEL019.0-046.5A Northeast wingwall at Abutment 3 has WEL019.0-046.5A Northwest wingwall at Abutment 3 is pushed 1 foot north (2) 5/14/2024 12:00:00 AM 1.25 inch gap and repair 5/14/2024 12:00:00 AM WEL019.0-046.5A Northwest wingwall backwall is bulging WEL019.0-046.5A Southeast wingwall at Abutment 1 cap is separated 5/14/2024 12:00:00 AM 5/14/2024 12:00:00 AM Page 18 of 25 WEL019.0-046.5A Southwest wingwall at Abutment 1 has 1.75 inch separation and pushed 2 inch north 5/14/2024 12:00:00 AM Page 19 of 25 a° Structure Inspection and Inventory Report Photos Inventory Inspection Date: 05/14/2024 Structure Key: WEL019.0-046.5A Channel Downstream WEL019.0-046.5A Channel looking east downstream 5/14/2024 12:00:00 AM Channel Upstream WEL019.0-046.5A Channel looking west upstream 5/14/2024 12:00:00 AM Elevation Page 20 of 25 WEL019.0-046.5A-b1 Elevation looking east 5/14/2024 12:00:00 AM WEL019.0-046.5A-b2 Elevation looking west 5/14/2024 12:00:00 AM General/Superstructure w E It WEL019.0-046.5A-c Superstructure looking north 5/14/2024 12:00:00 AM Roadway Page 21 of 25 WEL019.0-046.5A-a1 Roadway looking north 5/14/2024 12:00:00 AM WEL019.0-046.5A-a2 Roadway looking south 5/14/2024 12:00:00 AM Page 22 of 25 SQStructure Inspection and Inventory Report Inspection Date: 05/14/2024 Maintenance Items Structure Key: WEL019.0-046.5A High 302.01 - Signs Install new, repair missing/ broken Status Date Entered Open 05/03/2016 Problem Description Install OM3s at all rail ends. Target Date 12/31/2031 Deterioration Category Other (See Description) High 358.06 - Repair/replace/extend/raise/construct wingwalls, with piles, backing planks, closure strips, deadmen, etc. Status Date Entered Open 05/07/2014 Target Date 12/31/2027 Deterioration Category Rusted Steel Problem Description Replace backwall or clean piles and backwalls, and encase the substructure units in concrete. High 354.99 - Miscellaneous superstructure work Status Open Date Entered 06/13/2024 Problem Description Clean and paint Beam Q and add stiffener at web tear. Target Date 12/31/2024 Deterioration Category Rusted Steel Moderate 306.00 - Bridge Rail/Approach Rail/Guardrail - Installation, Replace Status Open Date Entered 05/08/2006 Target Date 12/31/2031 Deterioration Category Rail (BR or GR) or Fence Problem Description Install approach rails, transitions, and end treatments to meet current AASHTO/CDOT standards. Page 23 of 25 Moderate 355.00 - Clean and Paint Bridge Status Open Problem Description Clean and paint beams. Date Entered 05/03/2016 Target Date 12/31/2031 Deterioration Category Rusted Steel Moderate 206.01 - Remove debris/other obstructions/brush/trees/fence from channel or around bridge. Status Open Date Entered 09/24/2013 Problem Description Remove debris caught between beams. Target Date 12/31/2027 Deterioration Category Debris Build-up Moderate 358.03 - Fill scour holes around piers, abutments, and at ends of CBC's. Status Open Date Entered 05/07/2014 Problem Description Place riprap along both abutments and around pier. Low Target Date 12/31/2027 306.00 - Bridge Rail/Approach Rail/Guardrail - Installation, Replace Status Date Entered Open 05/08/2006 Problem Description Upgrade bridge rails to meet CDOT/AASHTO standards. Target Date 12/31/2031 Deterioration Category Erosion Deterioration Category Rail (BR or GR) or Fence Page 24 of 25 tee Streambed Profile 2020 -2.8 0 5 10 15 027 2020 2022 2024 �(J N 0 17.2 Structure Inspection and Inventory Report Report Inspection Date: 05/14/2024 Structure Key: WEL019.0-046.5A m Q S 0 10 12.8 26 39.9 45.3 53.3 8.7 9.5 11.3 12.4 12 9.3 9.3 87 8.7 8.2 8.2 7.8 8.5 11.4 9.3 8.3 10.3 9 16.2 14.9 8.5 Measurement Type 37.2 Reference Line Waterline 2024 (Upstream 10 05/14/24 Comments: N/A 26.0 2022 I Upstream 9.4 05/04/22 Comments: N/A 26.0 2020 [upstream 10.5 05/01/20 Comments: N/A 26.0 Page 25 of 25 Contract Form Entity Information Entity Name* Entity ID* COLORADO COUNTIES, INC @00002822 Contract Name* 2025 BRIDGE GRANT APPLICATION Contract Status CTB REVIEW Contract ID 10021 Contract Lead * MBEDELL Contract Lead Email MBedell@weld.gov New Entity? Parent Contract ID Requires Board Approval YES Department Project # GR-54 Contract Description* A GRANT APPLICATION FOR CONSIDERATION OF OBTAINING SUPPLEMENTAL FUNDS ASSOCIATED WITH THE BRIDGE 1 9/46.5A REPLACEMENT PROJECT. THE GRANT APPLICATION IS SEEKING AN AMOUNT OF $2,500,000. Contract Description 2 Contract Type * GRANT Amount * ($2,500,000.00) Renewable* N O Automatic Renewal N O Grant YES IGA N O Department PUBLIC WORKS Department Email CM- PublicWorks@weld.gov Department Head Email CM-PublicWorks- DeptHead@weld.gov County Attorney GENERAL COUNTY ATTORNEY EMAIL County Attorney Email CM- COUNTYATTORNEY@WEL D.GOV Grant Deadline Date 1 1 /07/2025 Requested BOCC Agenda Date * 10:29 2025 Due Date 10 25'2025 Will a work session with BOCC be required?* NO Does Contract require Purchasing Dept. to be included? NO If this is a renewal enter previous Contract ID If this is part of a MSA enter MSA Contract ID Note: the Previous Contract Number and Master Services Agreement Number should be left blank if those contracts are not in OnBase Contract Dates Effective Date Termination Notice Period Contact Information Contact Info Contact Name Purchasing Purchasing Approver Approval Process Department Head .CURTIS HALL DH Approved Date 10/232025 Final Approval BOCC Approved BOCC Signed Date BOCC Agenda Date 10/27/2025 Review Date* 1231 2025 Committed Delivery Date Contact Type Contact Email Finance Approver CHRIS D'OVIDIO Renewal Date Expiration Date* 12/31/2025 Contact Phone 1 Purchasing Approved Date Finance Approved Date 10/24/2025 Tyler Ref # AG 102725 Originator MBEDELL Legal Counsel BYRON HOWELL Contact Phone 2 Legal Counsel Approved Date 10/24.'2025 Houstan Aragon From: Sent: To: Subject: Mike Bedell Monday, October 27, 2025 2:16 PM Houstan Aragon; Esther Gesick; Don Dunker FW: Weld County 2025 CCI Bridge Grant Application From: Meghan MacKillop <meghan@nexuspolicygroup.com> Sent: Monday, October 27, 2025 2:09 PM To: Mike Bedell <mbedell@weld.gov> Cc: Evan Pinkham <epinkham@weld.gov> Subject: Re: Weld County 2025 CCI Bridge Grant Application This Message Is From an Untrusted Sender You have not previously corresponded with this sender. Use extra caution and avoid replying with sensitive information, cli, links, or downloading attachments until their identify is verified. Thank you Mike - This is received. We will be in touch with any next steps! Meghan MacKillop 720.308.0672 meghan@jiexuspolygroup.com On Oct 27, 2025, at 9:39 AM, Mike Bedell <mbedelt@weldgov> wrote: See attached. Please confirm receipt of this grant application, and let me know if anything else is required. <Weld County 2025 CCI Grant Application.pdf> Hello