HomeMy WebLinkAbout20243304.tiffINVENTORY OF ITEMS FOR CONSIDERATION
Applicant: Zen Midstream LLC cio Katie Gillen
Case Number: US R24-0022
Submitted or Prepared
Prior to
Hearing
At
Hearing
1
Presentation
from
the applicant
X
I hereby certify that the one item identified herein was submitted to the Department of Planning Services at or
prior to the scheduled Planning Commissioners' hearing.
Diana Aungst, Planner
ZEN MIDSTRI_AM
Ren Compressor Station
U5R24-0022
Presenting Today
ITI ZEN MIDSTREAM
• Katie Gillen - VP Regulatory Affairs and EHS - Zen Midstream, LLC
• Ed Trotter - Productions Engineer - Zen Midstream, LLC
• Cory Neighbors - Sr. Land Man - Zen Midstream, LLC
• Jennifer Teeters - Regulatory Permitting Analyst - Zen Midstream, LLC
Our Company in Weld County ZEN MIDSTREAM
• Zen Midstream is a wholly owned subsidiary of Bison Oil & Gas IV
Partners, LLC
OFFICER'S CERTIFICATE
The undersigned, being a duly authorized officer of Bison Oil & Gas TV, LLC, a Delaware
Limited Liability company (``BMW"), hereby certifies for and on behalf of BOGIV, and not in his
individual or personal capacity, that:
1. Zen Midstream., LLC, a Delaware limited liability company, is a wholly owned ubsidiar
fBUG] .
IN WITN lESS WHERTOL the undersigned has executed this Officer's Certificate as of
the first date written above.
BisoN OIL & GAS I, LLC
By:
Name: Christopher umbe
Title: Executive Vice President General Counsel
3
Project Overview
■ The applicant is requesting a SiteSpecific Development Plan and
Use by Special Review Permit for an Oil and Gas Support and
Service Facility (Compressor Station) identified as the Ren
Compressor Station, that will be owned and operated by Zen
Midstream LLC (Zen). The purpose of this project is to facilitate
the compression and transport natural gas produced at nearby oil
and gas production facilities.
ITI ZEN MIDSTREAM
■ The natural gas gathering pipelines in this area operate at a line
pressure above the pressure of the production facilities. The high
pipeline pressure prevents the gas produced at the production
facilities from entering the pipeline and being transported offsite.
■ Natural gas production from the surrounding production facilities
will be routed to the Ren Compressor Station where the gas will be
compressed so it can be transported offsite to the existing pipeline
infrastructure.
Project Overview Continued
121 ZEN MIDSTREAM
■ The new facility includes three (3) skid -mounted compressors, two (2)
blowdown vessels, one (1) BTEX knockout, two (2) produced water tanks,
five (5) scrubbers, two (2) separators, one (1) discharge coalescer filter, one
(1) gas/glycol exchanger, one (1) regen skid, one (1) BTEX skid, one (1)
glycol make-up tank, instrument air equipment, three (3) dry air receivers,
three (3) generators, two (2) VRUs, two (2) blowdown blowers, two (2)
BTEX lowers, two (2) pressure vessels, two (2) oxygen destructors, one (1)
air compressor skid, one (1) condensate treater, one (1) slug catcher, six (6)
pig launchers, three (3) pig receivers, two (2) LACT skids, three (3) sales
meters, two (2) 40ft storage boxes and other minor support equipment.
■ There will be onsite containment of fluids required for maintenance and
safe operation of equipment. Compressor coolant will be housed in three
(3) 500- gallon double -wall horizontal steel tanks stalled at grade. Eco
waste will be housed in three (3) 100 -gallon fiberglass sump tanks at
grade will be installed to capture all compressor drains. Six (6) 330 -gallon
methanol tanks and one (1) 1,000 -gallon glycol tank. Six (6) 500 -gallon
lube oil tanks, and two (2) 500 bbl produced water tanks each with
secondary containment.
Project Overview Continued
121 ZEN MIDSTREAM
■ During construction there will be approximately two (2) to eight
(8) workers on site. The facility will be unmanned during
operation, meaning no full-time or part-time personnel will be
specifically stationed at this compressor station, but the site will be
visited daily by both full-time personnel and contractors for
inspection and monitoring. During operation, the facility will be
monitored remotely on a 24 -hour basis. The site will be graveled
and fenced with minimum downcast lighting and operational
twenty-four (24) hours a day, seven (7) days a week, three
hundred sixty-five (365) days a year.
■ The site will implement a limited lighting regiment for internal
lighting and will be fully fenced utilizing a cattle guard for
vehicular access with the area inside the fence graveled and the
area outside of the fence will be re -seeded with an NRCS-
approved native seed mix. The applicants submitted a
Decommissioning Plan with the application materials.
Project Overview Continued
121 ZEN MIDSTREAM
LEGEND
WCR 7 (Gravel)
Driving Directions:
From the intersection of HWY 392 & WCR 74, continue
southeast approximately 0.2 miles to lW,'CR 74. Turn
east and proceed approximately 3.8 miles, continue
berth 0.5 miles, and then proceed east 250 feet to the
R en Compressor Station.
ZEN MIDSTREAM, LL+C
sass
__s
Ren Compressor Station
Haul Route — Paved County Road
Haul Rome — Gravel County Road
Haul Route — Existing Lease Rd
Haul Route — New Lease Rd
ZEN MIDSTREAM
Date: 4/24/2024
HAUL ROUTE
REN COMPRESSOR STATION
SWNW & NWSW Section 33 T7N R62W, 6th P.M.
WELD COUNTY, CO
7
Purpose & Need
ZEN MIDSTREAM
• The natural gas gathering pipelines in this area operate at a line pressure above the
pressure of the production facilities. The high pipeline pressure prevents the gas
produced at the production facilities from entering the pipeline and being
transported offsite.
• Natural gas production from the surrounding production facilities will be routed to
the Ren Compressor Station where the gas will be compressed so it can be
transported offsite to the existing pipeline infrastructure.
CROW VALLEY
_7-62-31
TRI fERFISH
(_ROW
VALLEY
_Will I hl Ali I RARRA000A
.,
WI111ETAIL
* SA''to
Purpose & Need
ZEN MIDSTREAM
• Service the following Drilling Spacing Units (DSUs), all scheduled for production
(Turn -In -Line "TIL") in 2025 and early 2026.
• Whitetail - Permits secured
• Barracuda - Permits secured
• Triggerfish - Permits secured
• Dorado - OGDP submitted, 1041WOGLA scheduled for Hearing 12/12/24
CROW VALLEY
_7-62-31
TRIGGERFISH
(_l II
CROW
VALLEY
_Will I hl Ali I RARRA000A
.,
=*, SA''to
WI111ETAIL
9
Weld County Code
121 ZEN MIDSTREAM
The submitted materials are in compliance with the application requirements of Section 23-2-260 of the Weld County
Code.
It is the opinion of the Department of Planning Services' staff that the applicant has shown compliance with Section
23-2-220 of the Weld County Code as follows:
• Section 23 -2 -220.A.1 —The proposed use is consistent with Chapter 22 and any other applicable code provisions or ordinance
in effect.
• Section 23-2-220.A.2 — The proposed use is consistent with the intent of the A (Agricultural) Zone District.
• Section 23-2-220.A.3 — The use which will be permitted will be compatible with the existing surrounding land uses.
• Section 23-2-220.A.4 - The use which will be permitted will be compatible with future development of the surrounding area.
• Section 23-2-220.A.5 - The application complies with Chapter 23, Articles V and XI, of the Weld County Code.
• Section 23-2-220.A.6 — The applicant has demonstrated a diligent effort to conserve prime agricultural land in the locational
decision for the proposed use.
• Section 23-2-220.A.7 — There are adequate provisions for the protection of the health, safety, and welfare of the inhabitants of
the neighborhood and County.
Sec. 22-2 — Principles, Goals, and Objectives
• Section 22-2-30.A.C — Harmonize development with surrounding land uses.
• The Facility is proposed for a remote location of the County. The closest residence is approximately 4,600 feet to the southeast of
the proposed project.
• Section 22-2-30.A.1 states: "Land use changes should not inhibit agricultural production nor operations."
• The request for a compressor station does not inhibit agricultural production nor operations.
• The current land use is rangeland for livestock grazing.
• Section 22-2-40.A.5 of the Weld County Code states: "Encourage agglomeration economies of synergistic businesses."
• The location of this proposed compressor station is in an area with multiple existing and planned oil and gas facilities that it would
serve. Additionally, there are natural gas pipeline easements within and adjacent to the parcel.
Weld County Code
121 ZEN MIDSTREAM
Sec. 22-2 — Principles, Goals, and Objectives continued
• Section 22-2-60.B. states: "Support responsible energy and mineral development."
• The request for a compressor station supports the local economy and the Oil and Gas Industry by supporting
the service of energy development and providing an alternative fuel source.
• Section 22-2-60.B.3. states: "Require that energy and mineral resource development conserve the
land and minimize the impact on surrounding land and the existing surrounding land uses."
• The proposed Ren Compressor Station is located in an area of the County used primarily as agricultural and
pastureland and already contains oil and gas operations and facilities.
Sec. 23-3
• Section 23-3-10. — Intent, of the Weld County Code states. "Agriculture in the COUNTY is considered
a valuable resource which must be protected from adverse impacts resulting from uncontrolled and
u ndirected business, industrial and residential land USES. The A (Agricultural) Zone District is
e stablished to maintain and promote agriculture as an essential feature of the COUNTY. The A
(Agricultural) Zone District is intended to provide areas for the conduct of agricultural activities and
activities related to agriculture and agricultural production, and for areas for natural resource
extraction and energy development, without the interference of other, incompatible land USES.
• Section 23-3-40.V —Uses by special review, of the Weld County Code allows for an "Oil and Gas
Support and Service" facility in the (A) Agricultural Zone District. This code section allows the
applicant to apply for the Ren Compressor Station, which directly supports the oil and gas industry.
Per Section 23-1-90 of the Weld County Code, "oil and gas support and service" allows for:
"Midstream activities including the processing, storing, transporting and marketing of oil, natural gas
and natural gas liquids." This compressor station is to expand and enhance natural gas that is being
collected from nearby production sites.
Engineering Data Points
121 ZEN MIDSTREAM
Specs and details of Ren System
o Low Pressure Gathering Pipe Specs
• 272 PSIG MAOP @ 140 F
• 10" API 5L PSL2 ERW X-52 0.219" W.T. FBE
O High Pressure Gas Lift Pipe
g pSpecs
• 1,440 PSIG MAOP @ 140 F
• 4" API 5L PSL2 ERW X-52 STD W.T. FBE
0 p Compression Specs and Details
O 3 x 2,373 hp Ariel JGD/4 Compressors/ Waukesha
9394S5 natural gas -driven engines 11.3 MMSCFD
@50 PSIG suction
0 40 MMSCFD Dehydration Unit, 5-7 lb/MM
Closed -loop dehydration BTEX vapor capture
O 100% facility blowdown capture of operations,
packing vents, including pigging & equipment
blowdown operations
Condensate storage and pipeline transfer via
pump to condensate -gathering pipeline
Produced water storage and pipeline transfer via
pump to produced water -gathering pipeline
Ren Station Layout J
1
Me
tr4.N
,f
I
ii
I.
�•-�
J
`'
.07
a 'jar
Mica
all
15.---rx
16 Lir
z
I
{!
IS
ti
5
ti 3
I
I'd
a
Mryl
�.
.•
.-c
.I
r - .c r
1
I
Used
A
—�J�. �
[�"J.n
li 1�� �. A
"r.�'
1.
IT
01CSI
flMiCINITIgal
Ides--
lift,
I
IT
I
ie
R
4.1
1
I
i
IT
Hello