HomeMy WebLinkAbout961965.tiff mEmoRAnDum
wink Keith Schuett, Lead Planner August 15, 1996
To Date
COLORADO Don Carroll, Project Manager f
From
Subject: USR-1126, Western Wireless
The Weld County Public Works Department has reviewed this proposal. The following comments
are recommended to be a part of any approval:
1. The I-25 Frontage Road access falls under the State's jurisdiction. Please contact Tess Jones,
Colorado Department of Transportation at the Greeley Office, to verify the new or existing
access and drainage at this location.
2. Four inches of aggregate base course needs to be placed on the north access road. This road
needs to be graded and drained to accommodate the facility.
3. The applicant needs to adhere to all County set-backs from rights-of-way or property lines
to the facility.
cc: Commissioner Hall
USR-1126
plan2
gct ' Cr".
\ti, ..,.
0
PSG19 �
G0
961965
DEPARTMENT OF PLANNING SERVICES
PHONE (970) 353-6100, EXT 3540
IDWELD
FAX (970) 352-6312
COUNTY ADMINISTRATIVE OFFICES
C1400 N. 17TH AVENUE
GREELEY, COLORADO 80631
COLORADO
DATE: August 8, 1996 CASE NUMBER: USR-1126
TO WHOM IT MAY CONCERN:
Enclosed is an application from Western Wireless for a Site Specific Development Plan and a Special Review
Permit for a 70' monopole radio communication tower and equipment structure. The parcel of land is
described as Part of the NW4 of Section 35,T4N, R68W of the 6th P.M.,Weld County, Colorado. The location
of the parcel of land for which this application has been submitted is approximately 1/2 mile north of Weld
County Road 38, east of and adjacent to 1-25 Frontage Road.
The application is submitted for your review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Your prompt reply will help to facilitate the processing
of the application. Please reply by August 29, 1996, so that we may give full consideration to your
recommendation. Please call Keith A. Schuett, Lead Planner, if you have any questions.
Check the appropriate boxes below and return to our address listed above.
1. We have reviewed this request and find that it does/does not comply with our
Comprehensive Plan for the following reasons.
2. We do not have a Comprehensive Plan, but we feel this request is/is not compatible with the
interest of our town for the following reasons.
3. We have reviewed the request and find no conflicts with our interests.
4. A formal recommendation is under consideration and will be submitted to you prior to
5. A Please refer to the enclosed letter.
Signed: `G�'f! Agency: G 'C ScAl-/may
Date: ,D 81112 9 O
Weld County Planning Dept.
AUG 2 6 7996
Wan :AA
961965
WELD COUNTY SHERIFF'S OFFICE
Ed Jordan, Sheriff
Office of Emergency Management
910 Tenth Avenue
Greeley,CO 80631-3873
(970)356-4015 ext.4250
FAX(970)353-8551
To Keith A. Schuett
From : Ed Herring
Date : August 22, 1996
Subject: USR-1126
There is no mention in the report if their will be back-up power in the forms of batteries.
Batteries in sufficient quantity require reporting under the Superfund Amendment and
Reauthorization Act (SARA) Title III of 1986. If their are no chemical on site then I would have
no problems with this USR. If there will be chemicals over the threshold planning quantity then
I would request that they be required to prepare a plan and annual reports per Section 302, 311
and 312.
If you have any questions please contact me.
Weld County Planning Dept.
AUG 2 6 1996
RECEIVED
961965
STATE OF COLORADO
,` DEPARTMENT OF TRANSPORTATION �q.
,[-
Region 4 SOT
1420 2nd street Weld County Planning Dept.'
Greeley,Colorado 80632-0850
(970)353-1232 Weld County, 1-25 EFR
AUG 3 0 1996 Western Wireless
'A Mile N. of WCR 38
,
ncbtiVED S.E. of Berthoud
August 28, 1996
Mr. Keith Schuett - Current Planner
Department of Planning Services
Weld County Administrative Offices
1400 N. 17th Avenue
Greeley, CO 80631
SUBJECT: Western Wireless Site Specific Development Plan
Keith, I have reviewed the above proposal, and offer the following comments:
ACCESS The plans indicate an access to the site located 550' north of the existing access. The
Department supports the location of this access provided there is adequate sight distance in
both directions.
The culvert size as shown on the plans is unacceptable. Culverts within the state highway
right-of-way must be 18" in diameter. Also, the access must be constructed at least 16' wide.
The applicant should contact me to obtain an access permit.
UTILITIES If new utility lines or connections are necessary within the state highway right-of-way, a
utility permit will be required. Prior to such utility work, Mr. Henry Rangel of the
Department should be contacted at (970) 350-2111.
Our comments are based upon the submittal as received August 12, 1996. Thank you for the
opportunity to review the Western Wireless proposal.
e l.l0--
G oria T. Hice-Idler
Access Coordinator
(970) 350-2148
cc: Fanning
file (2) EXHIBIT
961365
DEPARTMENT OF PLANNING SERVICES
PHONE (970) 353-6100, EXT 3540
FAX (970) 352-6312
WELD COUNTY ADMINISTRATIVE OFFICES
*lige 1400 N. 17TH AVENUE
GREELE Y; COLORADO 80631
COLORADO
DATE: August 8, 1996 CASE NUMBER: USR-1126
TO WHOM IT MAY CONCERN:
Enclosed is an application from Western Wireless for a Site Specific Development Plan and a Special Review
Permit for a 70' monopole radio communication tower and equipment structure. The parcel of land is
described as Part of the NW4 of Section 35,T4N, R68W of the 6th P.M.,Weld County, Colorado. The location
of the parcel of land for which this application has been submitted is approximately 1/2 mile north of Weld
County Road 38, east of and adjacent to 1-25 Frontage Road.
The application is submitted for your review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Your prompt reply will help to facilitate the processing
of the application. Please reply by August 29, 1996, so that we may give full consideration to your
recommendation. Please call Keith A. Schuett, Lead Planner, if you have any questions.
Check the appropriate boxes below and return to our address listed above.
1. _ We have reviewed this request and find that it does/does not comply with our
Comprehensive Plan for the following reasons.
2. We do not have a Comprehensive Plan, but we feel this request is/is not compatible with the
interest of our town for the following reasons.
3. We have reviewed the request and find no conflicts with our interests.
4. A formal recommendation is under consideration and will be submitted to you prior to
5. Please refer to the enclosed letter.
Signed: 1,(% Agency: 4ti h t?AA r P
Date: 1«s`
•
OQ4I rr
___J3--
961965
gpuNtuv N,JUNTAIN VIEW FIRE PROTEt., PION DISTRICT
AA Administrative Office:
if h '�'IY�, 8 9119 County Line Road •Longmont, CO 80501
B � ,��,� 8 (303) 772-0710 Metro (303) 666-4404 FAX (303) 651-7702
VIEW
Weld County Planning Dept
AUG 15 1996
August 13 , 1996
RECEIVED
Mr. Keith A. Schuett, Lead Planner
Department of Planning Services
Weld County Administration Offic'=s
1400 N. 17th Ave .
Greeley, CO 80631
RE: USR-1126
KTS/WIRELESS PCS III
Dear Mr. Schuett :
I have reviewed the submitted application materials for the above
referenced project . This project will be located within the
boundaries of the Fire District and will receive service from the
Fire District . The Fire District has no objections to this project
providing the adopted codes and standards of the Fire District can
be met . I have the following comments :
1 . The Fire District' s Standard for fire apparatus access roads
is an all-weather surface which shall be a minimum of twenty
feet wide, shall have an unobstructed clearance of at least
thirteen feet, six inches (13 ' 6" ) , and shall be capable of
supporting the imposed load of fire apparatus weighing at
least sixty thousand (60 , 000) pounds . It appears as though
the proposed road width meets the above requirements . If fire
apparatus access roads are not looped in such a way as to
allow driving completely around the building or complex of
buildings, then the dead-end fire apparatus access roads shall
meet the requirements of the following Table 3 . 04 : Refer to
copy enclosed. Due to the nature of this project, the Fire
District will accept the options listed for a roadway length
between 151-500 feet .
2 . Install a padlock from the Knox Company for fire department
access to the interior of the fenced area. Key access is only
available to Fire District Command Personnel . Contact the
Fire Marshal for an application form which will need to be
completed and returned with a check to the Knox Company. The
Fire Marshal will then provide an authorized signature on the
application and send the order in. The padlock will then be
shipped directly to the applicant . Applicant is to notify the
Fire Marshal when padlock is placed into service .
Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7
9119 Cnty Line Rd. 10971 WCR 13 P.O.Box 575 P.O.Box 11 10911 Dobbin Run P.O.Box 666 P.O.Box 40
Longmont,CO Longmont,CO 299 Palmer Ave. 8500 Niwot Road Lafayette.CO 600 Briggs 100 So.Forest St.
80501 80504 Mead,CO 80542 Niwot.CO 80544 60026 Erie,CO 80516 Dacono,CO 80514
961965
Page 2 .
3 . Mount one-twenty pound (2-B) rated Carbon Dioxide fire
extinguisher on a post separate from the fence, and inside the
gate. Contact the Fire Marshal for approval of location prior
to installation.
Applicant will need to schedule a final inspection with the Fire
Marshal prior to use of the facility.
If you have any questions, please let me know.
Sincerely,
William N. Bailey
Fire Prevention Manager
Fire Marshal
961965
3 . 03 Building Access for Ladder Operations
3 .03-1 . Buildings more than one ( 1 ) story in height shall be
designed in such a manner that ground ladder operations with
access to the interior can occur on the same side of the
building as the fire apparatus access route.
3 . 03-2 . Buildings or portions of buildings exceeding thirty-
five ( 35 ) feet in height from the lowest point of fire
department access shall be provided with a fire access route
capable of accommodating Fire Department aerial apparatus .
Required access roadways shall be a minimum twenty-six ( 26 )
feet in width in the immediate vicinity of any building or
portion of building more than thirty-five ( 35 ) feet in
height.
At least one of the required access roadways meeting this
condition shall be located within a minimum of fifteen ( 15 )
and a maximum of twenty-five ( 25 ) feet from the building, and
shall be positioned parallel to one entire side of the
building.
Note: The measurement for this requirement shall be taken
from the exterior wall of the building to the nearest edge of
the fire apparatus access road.
3 . 04 Dead-end Fire Apparatus Access Routes
3 . 04-1 . If fire apparatus roads are not looped in such a way
as to allow driving completely around the building or complex
of buildings , then the dead-end fire apparatus access roads
shall meet the requirements of the following Table 3 . 04 :
Requirements for Dead-end Access Routes
Length Width Turnarounds Required
0-150 ' 20 ' None Required
151 ' -500 20 ' 70 ' diameter cul-de-sac
70 ' Tee or 70 ' Y
501-750 ' 26 ' 96 ' diameter cul-de-sac
120 ' Hammerhead
Over 750 ' Special approval required.
*Curves and topographical conditions could alter the
requirements for turnarounds and the width of access roads .
961965
mEmORAnDUm
Keith A. Schuett
ELI Vt
Weld County Planning August 20, 1996
To DMe 1
COLORADO -
From Trevor Jiricek, Supervisor, Environmental Protection Service
Subject: Case Number: USR-1126 Name: Western Wireless
PT NW4 of Section 35, Township 04 North, Range 68 West
Environmental Protection Services has reviewed this proposal; the following
conditions are recommended to be part of any approval:
1. All liquid and solid wastes shall be stored and removed for final disposal
in a manner that protects against surface and groundwater contamination.
2. No permanent disposal of wastes shall be permitted at this site.
3. Waste materials shall be handled, stored, and disposed in a manner that
controls fugitive dust, blowing debris, and other potential nuisance
conditions.
4. Fugitive dust shall be controlled on this site.
5. The maximum permissible noise level shall not exceed the, residential
limit of 55 db(A) ] as measured according to 25-12-102, Colorado Revised
Statutes.
TJ/rb-0952