Loading...
HomeMy WebLinkAbout982236.tiff P FELSBURG COPY (1 HOLT & ULLEVIG engineering paths to transportation solutions August 21, 1998 Mr. Frank Hempen, Jr. Director, Weld County Public Works Department P.O. Box 758 Greeley, Colorado 80632-0758 RE: U ■- e erence No. 98-169 Dear Mr. Hempen: We have completed our traffic engineering review of the proposed Elms at Meadow Vale PUD site plan and traffic study for the development to be located on the southwest corner of WCR 5.5 and WCR 26, north of the Meadow Vale Farm development, east of Longmont. This letter provides our comments on both the traffic study (prepared by Matthew J. Delich, P.E., in May 1998) and the plan. TRAFFIC IMPACT STUDY In general, the traffic study prepared for the Elms at Meadow Vale is complete and was prepared using the most recent trip generation and intersection capacity techniques. We do offer the following comments: • No trip distribution was assigned to the north of the site; all of the traffic was assumed to utilize SH 119/WCR 5.5 to access the site. It is likely that some of the site generated traffic would access the site to/from the north. Both WCR 5 and WCR 7 are unpaved and provide a connection to SH 66, which extends east/west between 1-25 and northern Longmont. • The intersections of WCR 5.5/WCR 26, and WCR 5.5/site access were not analyzed in the study; the study focused on the intersection of SH 119/WCR 5.5. Currently, the intersection of WCR 5.5/WCR 26 does not have any traffic control. As mentioned above, it is likely that some of the site traffic would access the site to/from the north, therefore using this intersection. A STOP sign should be installed on the WCR 5.5 approach of this intersection. Additionally, the site access on WCR 5.5 should be STOP-sign controlled for traffic exiting the site access. 303.721.1440 fax 303.721.0832 thu@thueng.com Greenwood Corporate Plaza �AHIOaT 7951 E.Maplewood Ave. Ste. 200 En,Ic uxxi CO 801 I I 982236 aia August 21 , 1998 Mr. Frank Hampen, Jr. Page 2 • The intersections of SH 119/WCR 5.5 and SH 119/WCR 3.5 are both identified as locations for potential signal installations in the future on Map 2.2, titled "Structural Transportation Network", of the Weld County Mixed Use Development Plan Standards (Ordinance 191, February 1997) (WCMUD). It is our opinion that only one of these signals will be warranted, even in the long range future. As traffic volumes increase, both locations should be monitored to determine which should be signalized. SITE PLAN The site plan was also reviewed for meeting general traffic engineering principles, and a field trip was made to verify physical characteristics of the site. Following is a list of concerns based upon the plan and/or the field trip: • It is recommended that a second site access be considered. At build out, the site is expected to generate approximately 1900 vehicles per day (vpd). This volume suggests at least a collector is needed (arterial according to County Standards) as the entry road and that home frontage not be allowed. The plan proposed home frontage along the entry roadway and a second access (perhaps to WCR 26) would relieve this concentrated demand. A second site access may also be beneficial for emergency service reasons. Providing the second access onto WCR 26 may also better serve the site if the WCR 3.5 intersection with SH 119 is signalized and the WCR 5.5 intersection is left unsignalized. • The WCMUD Standards state that a two-lane, collector roadway should have a ROW of 80 feet, including two 12-foot driving lanes, a painted median turn lane, and two six-foot bike lanes. From field measurement, the existing ROW appears to be approximately 50 feet on WCR 5.5 and 56 feet on WCR 26. The plan identifies WCR 5.5 and WCR 26 to each have a cross section of 60 feet with two 14-foot travel lanes and 16 feet of shoulder/ditch on each side. • The WCMUD Standards indicate local, residential streets should have 60 feet of ROW, including two 12-foot travel lanes, two 8-foot parking lanes and 10 feet of curb and gutter, sidewalk, etc. on each side. For the local roads proposed for within the site, the plan identifies the following: • Boulevard - 112 feet of ROW with two, separated 12-foot travel lanes and eight feet of parking on each side, a fifty foot landscaped median and two eleven-foot shoulders/ditches. • Local Street - 60 feet of ROW with two 14-foot travel lanes, no on-street August 21, 1998 Mr. Frank Hampen, Jr. Page 3 parking, and 16 feet of shoulder/ditch on each side. • Private Drive - 32 feet of ROW with two 10-foot travel lanes and six feet of shoulder/ditch on each side. Neither the local street nor the private drive described in the plan meet the Weld County Standards for local, residential streets. The largest concern is that there is no on-street parking for the majority of the proposed development. Additionally, there is concern that emergency vehicles may not be able to maneuver in the planned Private Drive areas. • It is understood that the elementary school was included in the previous study and plan completed in March 1995 for Meadow Vale Farms. Planning for the school should incorporate pedestrian and vehicle access from within the neighborhood. Vehicle access to the school should also be provided from WCR 5.5 if the school is not to be served by a collector road within the already approved Meadow Vale Farms development. • The plan identifies planned landscaping, including trees and bushes, along the roadway within the site. The location of the landscaping should be carefully determined to ensure proper site distance is provided at intersections. If you have any questions, or need additional information, please do not hesitate to call. Sincerely, FELSBURG HOLT & ULLEVIG ` I2tJ /e.trE�'lJ 1 Debra L. Zer len, E.I. Christopher J. Fasching, P.E. Transportation Engineer Senior Transportation Engineer cc: Mr. Don Carroll . 0 re#0 , ,,...„, PUBLIC WORKS DEPARTMEN T WinPHONE (970) 356-4000, EXT. 3750 C. FAX: (970) 352-2868 933 NORTH 11TH AVENUE P.O. BOX 758 COLORADO GREELEY, COLORADO 80632 October 5, 1998 IILI U u 1E:2 Floyd Oliver 4250 W. 16th Street, #46 • Greeley, CO 80634 RE: Z-513,Elms at Meadow Vale Dear Floyd: We have received our Traffic Analysis Review from Felsburg,Holt,and Ullevig. In reviewing the proposal for the Elms at Meadow Vale PUD site plan and traffic study,additional information and requirements are as follows: The existing traffic study information only identifies movements from the Elms south to State Highway i . G 119. Additional information will be required for traffic flows to the north and impacts at the intersection of WCR 5.5 and WCR 26. Stop signs shall be installed at all approaches to WCR 5.5 and WCR 26. The consultant agrees with the requirement of a secondary access onto WCR 26 which will be installed (- to relieve additional traffic loads at the north end of the Elms. All these items shall be addressed prior to recording the final plat. Attached is your copy of the traffic analysis provided by our traffic consultant. Sincerrely�, AL ��Q 6.1461 Donald Carroll Engineering Administrator Enclosure DC/pjg {I[tt cc: Monica Daniels-Mike Frank B. Hempen, Jr. coe*5(3 Z-513 • • • 32.7 Bulk Reauirements for the R-1. R-2. R-3. R-4.and R-5 Districts. The following tables list the Bulk Requirements for the R-1, R-2, R-3, R-4, and R-5 Districts. REQUIREMENT El & R-4 RR=5 32.7.1 - Minimum LOT size (sq. ft.) 6,000 6,000 6,000 6,000 see 32.7.9 • 32.7.2 Minimum LOT area per residential structure (sq. ft.) 6,000. 4,500 4,500 3,000 " 32.7.3 Minimum LOT area/unit (sq. ft.) 6,000 3,000 3,000 1,500 " 32.7.4 Minimum SETBACK (feet) 20 20 20 20 32.7.5 Minimum OFFSET (feet) 5 feet or, one foot for each three feet of BUILDING HEIGHT, whichever is greater. 32.7.6 Maximum BUILDING HEIGHT (feet) 30 30 30 45 32.7.7 Maximum LOT coverage (%) 50 60 60 70 32.7.8 Maximum number of ANIMAL UNITS permitted per LOT Two (2) per LOT. Subject to the additional requirements of Section 47, Livestock Feeding Performance Standards. ANIMAL UNITS are not permitted in the R-2, R-3, R-4, and R-5 zone districts. REQUIREMENT R-5 • R-5 (MOBILE HOME PARK) (MOBILE HOME SUBDIVISION) 32.7.9 Minimum LOT area (sq. t) N/A 6,000 32.7.10 Minimum LOT width (feet) N/A 50 32.7.11 Minimum SETBACK and offset (feet) See Sections 32.7.11.1 See Sections 32.7.11 1 and 32.7.12.1 and 32.7 12 2 32.7.11.1 The minimum front yard SETBACK in MOBILE HOME PARKS and MOBILE HOME SUBDIVISIONS shall be twenty (20) feet. The minimum front yard setback for MOBILE HOME PARKS approved prior to January 25,.1978, and MOBILE HOME SUBDIVISIONS approved prior to January 1, 1965, shall be zero feet. The location in these parks and subdivisions for MOBILE HOMES shall be such that no MOBILE HOME or attached portion of a MOBILE HOME will encroach the nearest travel land or the ADJACENT road, flow line of the ADJACENT road or sidewalk ADJACENT Ito the MOBILE HOME. I 30-13 ORDINANCE 89-HH, October 21, 1997 2 EXHIBIT tZoZ #5/3 • provisions of the ordinance or otherwise deterring future similar violations, or reducing Federal financial exposure with regard to the STRUCTURE or other • DEVELOPMENT. • REPAIR SERVICE ESTABLISHMENT: Any BUILDING wherein the primary' _occupation is the repair and general service of common home appliances such as musical instruments, sewing machines, televisions and radios, washing machines, vacuum cleaners, power tools, electric razors, refrigerators and lawn mowers not exceeding four thousand watts(five horsepower), or any place wherein the primary occupation is interior decorating including reupholstering, furniture repair and the making of draperies, slipcovers and similar articles. RESTAURANT: An establishment that furnishes, for compensation, food and drinks or any kind for consumption primarily therein. A TEMPORARY snack bar or refreshment stand at a PUBLIC or nonprofit RECREATIONAL FACILITY and for the convenience of patrons of the facility, shall not be deemed to be a RESTAURANT. RESTAURANT. DRIVE IN: An establishment that furnishes, for compensation, food and drink of any kind for consumption primarily off the premises or which delivers food and drink to customers in their vehicles. RUNWAY: The area of the AIRPORT constructed and used for landing, and taking off, of aircraft. S „/ SETBACK: The horizontal distance between any BUILDING or STRUCTURE and the established PUBLIC or private STREET right-of-way line. If the abutting PUBLIC STREET is designated to be upgraded to a higher classification as defined by the Weld County Transportation Plan necessitating additional right-of-way, then the SETBACK shall be measured from the future right-of-way line. The future right-of- way line (measured from the center of the road) -is determined by dividing the needed right-of-way as defined below in half. The following is a list of the right-of- way needed for road designations as defined in the Weld County Transportation Plan. SCHOOL: Means and includes any one or more of the following categories: A • PUBLIC SCHOOL, community college, junior college, college or university; an• independent or parochial SCHOOL which satisfies the compulsory SCHOOL • attendance requirements appearing in the School Attendance Law of 1963(Colorado Revised Statutes 1973, Article 33 of Title 22); but the word SCHOOL does not include dance schools, business schools, trade schools, or driving schools. SCREENED: Construction and maintenance of fences, earth berms or the USE of landscaping materials or other materials used with the approval of the Department of Planning Services to lessen the noise, light, heat or visual impacts of a USE on surrounding USES. SECONDARY RECOVERY: A technique of recovering additional crude from a mineralized zone by injecting steam,water and similar methods in an effort to force more of the crude to a production well. 10-18 ORDINANCE 89-HH, October 21, 1997 I 1. Cotton bearing Cottonwoods (Populus) 2. Siberian and Chinese Elm (Ulmus) 3. Tree of Heaven (Allianthus) 4. Russian Olive (Eleagnus Angustifolia) 5. Purple Loostrife (Lythrum Salicaria) 3. Buildings and parking areas shall be located to preserve and promote the health of existing trees. The applicant shall be responsible for locating and preserving, where feasible, all individual trees of 4-inch caliper in size or larger, and massed groups of small trees. Before construction, the following precautions shall be taken to preserve quality trees: a. The applicant shall submit to the Department of Planning Services a detailed landscape plan delineating the existing and proposed trees, shrubs, ground covers, natural features such as rock outcroppings, and other landscaping elements. The plan shall show where landscaping exists or will be located along with planting and construction details. Where existing plantings are to be retained, the applicant shall include in the plans proposed methods of protecting the plantings during construction. b. The applicant shall demonstrate to the Department of Planning Services that the maximum possible landscaping was preserved or relocated through the development process. c. Heavy equipment shall be kept at least 5 feet from tree drip lines to prevent tree roots from being damaged. (t Whenever the use of the property to be developed or redeveloped will conflict with the use of adjoining property, there shall be an opaque planted screen between the two properties. The screen shall moderate the impact of noise, light, aesthetic concerns, and traffic. 5. All landscapes shall strive to maximize the use of native species. Where native material is not appropriate for the intended use or appearance, plant species that are regionally adapted and non-invasive shall be used. 6. Fescue, brome/fescue, or other turf types shall be used in lieu of bluegrass where heavy foot traffic is not anticipated. Seeding versus sodding of all turf types is preferred when the growing season allows for adequate germination and establishment of the turf to sufficiently control erosion. 7. Landscape areas shall be configured to maximize their interconnectivity within the site, to natural areas, and to landscape areas within existing or future adjacent development. Small isolated islands of landscaping except as required in parking lots and for II Mixed Use Development Plan Page 22 Hello