Loading...
HomeMy WebLinkAbout972859.tiffCOLORADO July 16, 1997 Mike Cervi Northern Colorado Brine P.O. Box 169 Sterling, Colorado 80203 Dear Mr. Cervi: DEPARTMENT OF HEALTH 1517 16TH AVENUE COURT GREELEY, CO 80631 ADMINISTRATION (970) 353-0586 HEALTH PROTECTION (970) 353-0635 COMMUNITY HEALTH (970) 353-0639 FAX (970) 356-4966 IOW Weld County Planning flDept JUL 1 8 19S7 0 l,. On June 19, 1997., a representative of the Environmental Protection Division (the Division) of the Weld County Health Department inspected Northern Colorado Brine, located at 10600 Weld County Road 54, Milliken, in Weld County, Colorado. The purpose of the inspection was to inspect and assess the facilities compliance with the "Regulations Pertaining to Solid Waste Disposal Sites and Facilities" (the Regulations) as promulgated by the Solid Waste Disposal Sites and Facilities Act, Title 30, Article 20, Part 1, C.R.S., as amended, and the Operational Standards as set forth in USR-540:83:3. On this date, it was observed that the facility's day-to-day operations were in substantial compliance with the "Regulations Pe . -inIn to Solid -Waste Disposal Sites and Facilities" and the Operational Standards as set fort i • USR-540:8 :3. However, one observation was made which requires additional clarification and information. It is as follows: 1) The liner in Pond C appeared to have been recently dug up. According to the facility operator, Herb Ikenouye, liquid nitrogen had been added and disked into the soil in order to enhance remediation. As we have indicated in previous correspondence, due to the potential for comprising the pond liner, prior to placing waste in Pond C, as well as pond D and E, you must submit a testing plan to both this office and the Solid Waste Section of the Colorado Department of Public Health & Environment (CDPHE) for review and approval. The results of any future testing must be reviewed and approved by the Weld County Health Department and the CDPHE prior to use of the ponds. We recommend that prior to conducting additional remediation on the site, a comprehensive remediation plan should be submitted to both the Division and the CDPHE for review and approval. Submittal of such a plan will allow us to review and comment on the plan in order to provide some assurance that the remedial activities will not have to be duplicated sometime in the future. 91185B PL co59 Mike Cervi July 16, 1997 Page 2 In addition, the Division is concerned about one additional item According to Section 4 5 7 and other citations m the facility's design and operations plan, "there is no existing groundwater beneath the site other than that which might exist below the Pierre Shale " However, records on file in our office indicate that groundwater is present m the underdram Therefore, the presence of water in the facility underdram indicates a liner failure In accordance with Development Standard 7 F of USR-540 83 3 the Division requests that the ongin of the water in the underdram be determined As you are aware Development Standard 7.F. states "In the event it is concluded that the evaporation ponds are leaking or liquid waste is detected in the seepage detection system, the County and State Health Departments shall be notified immediately Receipt of all waste -at the facility shall be discontinued until it can be determined by the State or County Health Department, from evidence presented by the operator or State/County Health Departments, which pond(s) is leaking The defective pond(s) shall be drained and repairs completed immediately in accordance with Operation Standard Seven (7)B " As you are aware, we have also made this request in previous letters dated November 14, 1996, May 1, 1997, and May 22, 1997 Please submit a comprehensive response to this letter, including a plan for the determination of the origm of the water in the underdram no later than August 1, 1997 Agam, I must advise you that failure to address the above items will leave us no choice but to recommend to the Weld County Planning Department that they consider scheduling this facility for a probable cause hearing I would recommend that we meet in the very near future so that we can discuss our concerns with the underdram at the facility If you would like to meet or if you have any questions, please do not hesitate to call me at (970) 353-0635, extension 2232 Sincerely, I Trevor Jincek Supervisor Environmental Protection Services tj\684 cc• Todd Hodges, W.C Planning Department Roger Doak, Colorado Department of Public Health & Environment Lee Morrison, W C Attorneys Office Hello