Loading...
HomeMy WebLinkAbout940563.tiff STATE OF COLORADO COLORADO DEPARTMENT OF HEALTH �401'co� Dedicated to protecting and improving the health and ' environment of the people of Colorado • .•G•.: * 4300 Cherry Creek Dr.S. Laboratory Building • Denver,Colorado 80222-1530 4210 E.11th Avenue ra'le' Phone(303)692-2000 Denver,Colorado 802 20-3 71 6 (303)691-4700 Roy Romer Governor March 3, 1994 Patricia A.Nolan,MD,MPH Executive Director Rick Hoffman Laidlaw Waste Systems, Inc. P.O. Box 320 Erie, Colorado 80516 RE: Request For Design Flexibility Denver Regional Landfill (South) Weld County Dear Mr. Hoffman: The Hazardous Materials and Waste Management Division of the Colorado Departrient • of Health (the Division) is in receipt of your letter dated February 8, 1994, requesting dsign, flexibility for the leachate collection piping, up-slope riser piping, one inch thick HDPEipad in the sump and geotextile cushion for the Denver Regional Landfill (South) located in Weld County. The Division has the following comments regarding your request for design flexibility: Leachate Collection Piping and Up-Slope Piping Please provide the manufacture's specifications on the proposed corrugated HDPE piping which demonstrates that the piping is developed for solid waste landfills and is compatible with the leachate generated at these facilities. This information needs to be placed into the Division's files. One Inch Thick HDPE Pad in Sump Provide calculations which demonstrate the HDPE pad is no longer necessary to protect the HDPE liner when utilizing the corrugated HDPE piping. Geotextile Cushion Provide a copy of the grain size distribution of the material which was utilized for the load test. Please provide publications which detail procedures for geomembrane load tests which represent the test you performed. Please demonstrate that performance of the load test for a 24-hour period at 30 percent greater then the maximum design load, represents the maximum degradation of the HDPE geomembrane liner which will occur over the life of this facility. 0-096 ()"'g, 104 L:c.. /)G. //L__ 94O563 ctoq,1.5 Mr. Rick Hoffman March 3, 1994 Page 2 In summary, the Division approves the use of corrugated piping. However, the additional information requested above is needed to evaluate the elimination of the one inch thick HDPE pad and the geotextile cushion. If you have questions regarding this matter, please contact me at 303-692-3437. Sincere y, Roger Doak Geologist Solid Waste Section Hazardous Materials and Waste Management Division cc: Weld County Commissioners Weld County Planning Department T. Jiricek, Weld county Health Department D. O'Sadnick, Golder Associates, Inc file: SW/WLD/LAI (South) 2A Hello