HomeMy WebLinkAbout861501.tiff •
DEPART ArNT OF PLANNING SERVICES
•
e4 ' PHONE(303)°56-4000 EXT 4400
915 10th STREET
!r� GREELEY,COLORADO 60631
) _ �O
COLORADO
December 31, 1986
Pat Martin, Executive Director
Humane Society of Weld County
P.O. Box 398
Greeley,CO 80632
Dear Pat:
The Department of Planning Services Staff has reviewed your request to
construct and operate a cremation unit at the Humane Society as part of
Special Use permit #323:76:28. The request described and shown in your
letter of December 19 is not considered a change from the approved Special
Use permit. The construction of the cremation unit will require building
and electrical permits in accordance with the Weld County Building Code
Ordinance.
Sincerely,
Rod Allison
Principal Planner
RA:dy
801501
HUMAN; SOCIETY OF WELD ‘../OUNTY
P.O. Box 398 —Greeley, Colorado 80632
23700 Highway 263
(303) 356-3550
Rod Allison
Dept. of Planning Services
Weld County
915 10th St.
Greeley, CO . 80631 December 19 , 1986
Dear Rod,
Please consider this a request for permission to construct and
operate a cremation unit at the Humane Society. Our reasons for
desiring such an operation are three-fold:
1) To be able to provide humane disposal of the county' s
unwanted pets ;
2) To provide a dignified method of handling the deaths of
pets for private citizens ;
3) To provide a cost-efficient, environmentally accepted method
of disposal of such unwanted animals in light of anticipated
health restrictions on landfill disposal .
As per our conversation of December 17th, I have enclosed manufac-
turer specifications on the cremation unit, a rough drawing of the
proposed location of the unit on our property, and a contractor' s
bid detailing the necessary construction work.
Your attention to this matter is appreciated. Should you require
any further information, please do not hesitate to call . Thank
you for your time.
Sincerely,
Pat Martin
Executive Director
Enclosures
L`u 2 1986
A Non-Profit Organization Dedicated to the Preventio -�i �_ nimals
Weld Co. Piaauag
HUMA_,E SOCIETY OF WELL I OUNTY
P.O. Box 398 —.Greeley, Colorado 80632
23700 Highway 263
(303) 356-3550
PROPOSED CREMATORY
ROUGH DRAWING OF LOCATION N
E4__ w
S
r State Hwy. 263
Driveway Fencing
Front door
Shelter
X Proposed CD
Back door cremation o
unit H.
crq
ac
.,-I
o
a)
4, Barn
Fencing
iuA Non-Profit Organization Dedicated to the Prevention of Cruelty to Animals
EQUIPMENT & ENGINEERING CO.
Asa
P. O. BOX 593243 •436 W LANDSTREET ROAD•ORLANDO, FLA 32859 • (305) 851-0993
JIM CRAWFORD
PRESIDENT
~ * * SPECIFICATIONS * *
C-500P
I. EQUIPMENT:
Crawford Multiple Chambered Pathological Incinerator
Natural Gas, LPG or oil fired.
II. MANUFACTURER:
Crawford Equipment & Engineering Co. ,
436 West Landstreet Road
Orlando, Florida 32824
III. CONSTRUCTION STANDARDS:
The Crawford Incineration Chamber shall be constructed of U.L./CSA
listed components and will meet or exceed nationally accepted
incinerator construction standards per the Incinerator Institute of
America (IIA) publication guidelines; i .e.:
A. Primary Chamber will not exceed 60% of total chamber volume,flue
connection shall not be considered part of furnace volume.
B. Flame Supervision thru Honeywell ultraviolet continuous scanning
flame detectors on all burners.
C. High Temperature Refractory Construction with air-cooled walls to
prevent excessive heat radiation.
D. Exhaust gas temperature reduction.
IV. INCINERATION CHAMBER DIMENSIONS:
Length: 8ft. 6in. Height: 6ft. 9in. Width: 3ft. 6in.
See blueprint number 850501 , dimensional and utility information.
V. OPERATING TEMPERATURE:
1 ,900 degrees Fahrenheit (primary chamber)
2,100 degrees Fahrenheit (secondary chamber)
VI. CAPACITY:
FIRING RATE: 75 lbs/hr
LOADING RATE: 125 lbs/hr
VII. DRAFT:
Induced.
VIII. SHIPPING WEIGHT:
10,000 lbs.
IX. EMISSIONS:
The Crawford Incineration Chamber shall meet or exceed local , state
and Federal environmental regulations.
X. EMISSION CONTROL:
Secondary chamber with one 500,000 BTU burner and hot air duct
opacity supervision by a Heat-Timer Corporation electronic exhaust
gas scanner with control to the primary chamber burner.
XI. STEEL CONSTRUCTION. SPECIFICATIONS:
A. The incinerator chamber structure to be heavy steel "I" beam,
square tube and plate steel welded construction.
B. Subfloors to be 3/16" steel plate, seal welded construction.
C. The exterior shell to be 12 gauge steel removable panels.
XII. REFRACTORY SPECIFICATIONS:
A. Chamber Floors: 3,000°F. abrasion resistant castable `
refraptory, 7" thick.
B. Chamber Ceilings: 3,000'F. arch cast monolithic castable
refraptoryy,7" thick.
C. Chamber Walls: 2,800"F. alumina-silicate fire brick,
2i" x 4i" x 9", 7" thick.
XIII. SKIN TEMPERATURE CONTROL:
Completely air-cooled design to prevent excessive heat radiation.
XIV. COMBUSTION EQUIPMENT:
A. Combustion Air: One single phase 230 volt, 3 H.P. air
blower motor.
B. Primary Chamber: One, down-fired, 500,000 BTU North
American burner -- gas fired.
C. Secondary Chamber: One, 500,000 BTU North American
burner -- gas fired.
D. Ultraviolet Flame
Safeguard: Control supervision on each burner.
E. Preheated: Combustion Air, (improved fuel economy)
F. Low-Draft Pressure
Safety Switch: Interlocked to all burners.
T
XV. EXHAUST GAS TEMPERATURE REDUCTION:
Hot air duct operating temperature: 900 degrees Fahrenheit.
XVI. HOT AIR DUCT SPECIFICATION OPTIONS:
10 gauge steel high - temperature refractory lined duct-patented.
XVII. UTILITIES REQUIREMENT:
A. GAS:
1 . Size: li" diameter gas line per unit.
2. Pressure:
a) Natural gas: 6" to 9" W.C.
b) Propane: 11" W.C.
3. Flow Rate:
a) Natural gas: 475 ft.3/hr.
b) Propane 4.75 gallons/hr.
B. ELECTRICAL:
1 . One 230 volt single phase connection for a .
3 h.p. motor.
2. One 115 volt, single phase 10 amp connection.
XVIII. INCINERATION CHAMBER DOOR:
Manual , counter-balanced, down operated with special locks.
XIX. INCINERATOR PROCESS CONTROL:
Entire incineration cycle controlled automatically via a timer
control electronic relay system with manual override capability.
Visual conformation of system process status through control panel
performance display readouts.
XX. EXTERIOR FINISH:
The incineration chamber is finished with two coats of high-tempera-
ture silicone and textured polyurethane coating.
ry
r SPECIFICATIONS
y `Y.a r Ys.t. �h y .Z _ _ f+at•~ [t.,,,,,--,u oi �,,
i - , i :p,,,..1.:,:,,,
` -,:,. .,4'-;'- -7, ' • { ''Fu Y _ Nei -'g ' '� y.
Unit- � �` ;. -, v Dimensions
1-10110V LP-416 ft3/hr LP- , '
-.' 10 AMP 7"w c. 197 ft'/hr I Height— 6' 9"
C500 P) 125 lbs/hr. 75 lbs/hr. 1200 CFM 10,000 lbs i Length—8'-6"
/ 1-10 220V NG-1000 ft3/hr. NG- r• _3'-6"
�_ r Width
('iLi,l-i Lt•it ,i4 2_ 50 AMP '4"w c. 475 ft3'hr r
1-10 110V LP-833 ft'%hr LP-
10 AMP 11"w.c 395 ft' hr Height--6 -9"
C1000 P 250 lbs'hr 150 lbs/hr. 2100 CFM 22,000 lbs Length - 12'
1-10 or 30 NG-2000 ft3"hr. NG-
Width - 6'
- 220V 75 AMP 7"w.c. 950 ft3/hr.
'•a
1-10 110V LP-833 ft''hr. LP-
10 AMP 11"w.c 395 ft' hr Height - 6'-9"
C1000 S 250 lbs/hr 200 lbs/hr. — - 2400 CFM 25,000 lbs Length 12'-6"
1-10 or 30 NG-2000 ft' hr. NG-
Width - 6'-,"
0.x, t ,-'L - =�� 220 V 75 AMP 7"w.c. 950 ft?'hr
1-10 110V LP-833 ft3 hr
10 AMP 11"w c LP 395 ft3'hr.
per chamber Height �"
C3200 P per chamber per chamber 2100 CFM
100 lbs'hr 300 lbs/hr 45,000 lbs `Length' 14'->t"
1-10 or 30 NG 2000 ft' hr NG- 950 ft3 hr per chamber
220 V 75 AMP 7"w c Width 8' '"
per chamber per chamber per chamber
1-10 110V LP-1250 ft3 hr. LP-
10 AMP 11"w c. 666 ft3/hr Height 9'-n'
C5000 P 500 lbs hr. 500 lbs./hr. 6000 CFM 34,000 lbs Length-- 14'-h'
1-10 or 30 NG-3000 ft3 hr NG-
Width— 11'
220 V 75 AMP 11"w c 1600 ft3,hr
All Crawly.rd units exceed state and ledenll environmental requirements
i ii.lotilI I.qu11nncnl(Cr bi,Ji1k'ctvn�> Coin/Jany> 1on11A11InW contein/>onlry>terhin 103>y II'ith traditional irafttnanship.
1 trli.;iii ow,28 years of expel il'nce in lnctnciator manufacturing,turing, II'e dt:,li,Ai and fabricate all of our incineration equipment.At CrauNf onl, the
quality, in ineeriun>,and attention to detail go into every product before our name,t>occ on it. This quality control(WU/CS you of consistent depen-
dability found in all Crau ford products
JA4•••••
ecr#A/
•
VQ ` y �-� �F.OUIPMENT&ENGINEERING CO.
T2;
."ENGINEERING,`
'Str! ,,/ t/i ant /0 1n u)'lulpJn ,'gilit'iln'n''
I
I
P.O. Box 593243 • Orlando, Florida 32859 • (800) 228-0884 / (305) 851-0993
I
Z'''•
2athological/, Taste Incinerati
, ..
: ,..... , .....,...„,:, _,„.„...„,.•,•,3-.4,:ef 17`..-'7 r:"7-';';''''‘ `"-'•---- r-*-r17,-- 1 •,, `:- '''•„`.: ` `,. -''''`'-",-;:•', '''''`., „:. --1, ;--`7--J(".-;
r , '}"'''r,° 4•'—'`'''','•''� r �, a ,''s ,. -'' w� . '• ,.s•:<•r '' C: r.'}''ve,'x it— • •
- •Fully aitonmattc pr -p ograzr c ,b Jr° ;',,-';A- '' `,1,# 40 }gig evenLy&smlbu't ft uis ati n
1 • e a -: r "S''',-,';''''-,1'
'�'.#, ., t ty taut and tested ",' .z' ;4.Sr+tn-
f�1L 4OO "''''. ma
'�r
•Ali wel `I C �3Cior2t. -',''" ,r ` s . - -•24 our'service-• ix,a ".,
- •'Natur41'; '1,1.2 gas&rei '=; .<' `' . 'r- ,444,a, f `'`• ,'•High tern-pe raturr,;'heauy-duty, rel C• • orles�:
•Designed for'one man pc a•,.,"'iz � .`. '�,,' ', °� 'i" r`•Gr�taranteed to,meet EPA re lr exits . .
. •Utilize` wrr 'it d n 'a -,. r . . , ,
Photoelectric sc a wer'to � r i r `erat t a e s - ' •
• �� � � ,-�,�. 1�cemstru�tioiy certified personnel'With highest!` '
•All bur rsrbave air flow i toe d) , k1 e , controls '- quality material atnd';x>mponent F
l '
' „ .. - a 4.,,.'a:a A -, xr $e U, - -�- e- x - 4tev" :— ,a'.
T
16 3,
M--n GAS
:. LI O • x fi
,? O6' C 1000 S I
" i ' t•
< "4.;1: The O1000 S, a counterpart to our C1000 P,
C 1000 S "
-•, }� ` 's, ':: incorporates a side unloading door which enables
this machine to piocess 2000 lbs/day. Its
. • 4 .. 4 additional insulating pi and redesigned
r `
steel and refractory areas permit continuous *'
loading and unloading while achieving high y i '
consumption rates. !
4--6'44- ——6'2"-- --re 2'—4
I
•
HEIGHT E.
• 6,9„
1
a
r.�GAS 1'6 r,3,
` 5 - •• ~ F-Ip O O
r., - y...za, ;s C3200 P
y
e The C3200 P is designed to allow 3000
e .4: ti i4lbs/day consumption rate in the least C3200P'' } ' s c ' € r � ). ; amount of space. The C3200 P design
�' n1 ,. ,,, houses two identical but separate in
cineration chambers which can be
`' � , ` ; operated together or separately from one
glny`. ,,' `• automatic control panel , i
..;.;.;-,,,r4.- ..2„, l
, 1 _._ ,,,,,,,, ..,..,.. „.2 „,,,,fir.; ' t2'-Mr 8'2" 2'4
5 % ' ,;i HEIGHT
7'8„
on Chambers � mwom Crawford
, .
GAS
• 7 x �r
�y f- ra 3� O
I 92C 500 P
x C500 P cor
r =`, ' . The O500 P is desigiicd foi batch loading or continuous feed
s I disposal up to 900 lbs/day. Its compact design enables
x I'_- ,x_r I installation in restricted areas and front loading makes it easy 42,►1 s'6" * 2 r
to operate.
•}
3 f e
i'''* *, 'i '' Vs? 8' HEIGHT
r 7 t 6'9"
I
�'6„ AS G , -
.
M--P4
f x = S.,
C1000 P ;; t.
. .
The O1000 P is a three burner incinerator
C1000 P N with a consumption rate of 1500 lbs/day
Utilizing exclusive features such .is °
refractory-lined stack,removable side panels,
fully automatic controls and performance
display readouts,its performance capabilities
y I- are unmatched. The C1000 P is the most
w 2'.+. 6'2„ _ +t�2-+ efficient, reliable and competitively priced
unit available.
HEIGHT m
6,9„
I
' • 8'
_ 4\ GAS
Y} o ll I
___ O5000 P
ic
The O5000 P n the industry's most tecluio C 5000 P o
logically advanced pathological waste
I.
incinerator. The C5000 P is designed for
J continuous operation and mass disposal
work. This machine will process 4000 to
T i4 5000 lbs/day i i
1, • ,
ti .-2'-N.---11'2" -r-2'4
F . 1
FP HEIGHT N
9'8„
PROPOSAL
• Belfiore Construction Proposal No.
4207 22 nd St Rd
Greeley, Colo. 80634 Sheet No.
Date December 12,198 5
•
Proposal Submitted To Work To Be Performed At
Name Humane Sbeiety of Weld County Street Same ---
Street-200 Highway 263 • City State
City Date of Plans ---
State_ Architect
Telephone Number X56-3550
We hereby propose to furnish the materials and perform the labor necessary for the completion of
- _- -1-0_-.ft._x20-ft.-. Building to house the Crawford-0500P Floor plan and exterior drawing
- inciud - _
- .-the-f a monolithic reinforced cono E.e- — -- -
--- • /Al n
•
- T d'Oo, rs to be metal double entry --
-.._ __ _iil4_ inside_)A to bA unfi ni sloe ---•------ -
_ _.The_nxterinr is to be pAinted with lAtex flat paint ---- -----
-'L'he roofing _be 25 year Fiberglass shingles -- -- --
-a11-the around the building -----—_
All -electrical-and.-gas lines to unit are figured in bid -- — --
' he price --_- - -_-__-
The installtion of flue nd the manufacturing of rain collar i s fi girad in,-price -
The price_ includes a 0 ft. x 12 ft. walkway to new structure - ------------- -
- * kch - --
______*_ __AL-aharge, of $600,00 is for putting Electric line for Hot water heater and lights-in- n
_ *_- , r_hargq_of 460.00 is for running electric line for dryer ----
- _-_-_gl l -arana
All material is guaranteed to be as specified, and the above work to be performed in accordance with the drawings
and specifications submitted for above work and completed in a substantial workmanlike manner for the sum of
Dollars ($ 6650.00 )•
with payments to be made as follows: Paid in full upon Completion
Any alteration or deviation from above specifications involving Respectfully submitted --------
extra costs, will be executed only upon written orders, and N
will become an extra charge over and above the estimate. All -
agreements contingent upon strikes,accidents or delays beyond Per ----
our control. Owner to carry fire, tornado and other necessary ' e
insurance upon above work. Workmen's Compensation and Not This propose may be withdrawn
Public Liability Insurance on above work to be taken out by
by us if not accepted within days
ACCEPTANCE OF PROPOSAL •
The abode prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as
specified. Payment will be made as outlined above.
Signature — --
Date_---- - - - --- - — — — -- - — - -- - - Signature -- — ------ — — -
TOPS F OFtM NO 3750 LITHO IN USA.
Y
O
-..t r
•
> 111-,---% /\N/ [
- z�
/,Q
,a .
..
"..:\,. ‘ z.
. \
\ ,,,„,,,, \
.\\ ,;,_;.,4„, .-- ,
. .
..
%\ N,.,-,--1. •\
, c31.\. \ ,
'\ \
,\ --A \ \
A.' \ _ __ _____ _ _
\i o /
..._ \ ,
L / ,
_ ,_ - tv ,
4,
\ ..,
..
P \Z ,,o, v, i
.,,,-
o� 19 !
`( ���
' 9
.
p
L
J .
. _
o
1=0',
. '''' .[--0\iwAtt161
1 CrYI?)
GocbP i
%
I 63Y orilvar ) I
•
..o I 1
1
,J-2x4 -tad
4-lyto79, 5-12 ---- 1I c..dr•le-r 5-re' .-;,1,./.., �,V A To
"4- I p vlr0
1 I/ 'I ion h1ctloRs
1 1
1 I
) 1G.bUD coin SLID Gvr2_
_.,12!!_)11„_ _ V-O" s s �i1 oq � 2!o",
ce-,,-------Z-- )t...L.e
-ISI, 101 ',6
1 --------1O`o" ..-. Go►h-il Cam,
HUMANE SOCIETY OF WELD COUNTY
SPECIAL USE PERMIT
DEVELOPMENT STANDARDS
1. The permitted use on the hereon described parcel shall be
an animal shelter facility as displayed on these Special
Use Permit plans.
2. The following restrictions or limitations shall be enforced
due to the location of the animal shelter facility adjacent
to the Weld County Municipal Airport:
a. No structure or object of natural growth shall pene-
trate the airspace above 4, 798 feet above mean sea
level within the Horizontal Surface as defined on the
Weld County Municipal Airport Zoning Map.
b. Any structure including communication towers and/or
antennas in excess of 40 feet above the site elevation
must have the approval of the Board of County Commissioners
who shall receive a recommendation from the Weld County
Municipal Airport Board before making their decision.
Radio towers and other uses similar in nature must be
approved through the Conditional Use Permit process.
c. Precautions shall be taken in the manner in which the
lighting is installed on the property so as not to
create a safety hazard for landing aircraft. Lighting
shall not be flashing or blinking and colored lights
shall not be permitted.
3. The Special Use Permit area shall be maintained in such a
manner so as to prevent soil erosion, fugitive dust, and
the growth of noxious weeds.
4. All applicable Weld County and State Health standards and
regulations shall be complied with by the persons managing
the facility.
5. Access to the animal shelter from the State Highway 263 shall
be limited to the one access point as shown on the Special
Use Permit plans . A driveway permit shall be obtained through
the State Highway Department. All interior roads and parking
areas shall be graveled.
6. An additional 35 feet of right-of-way on State Highway 263
shall be protected by setback as shown hereon.
,
Humane Society of Weld County
Development Standards
7. All structures shall be setback a minimum of 85 feet from
the existing right-of-way on State Highway 263 as displayed
on the Special Use Permit plans.
8. The following security measures shall be implemented:
a. A seven foot chain-link fence shall be built around the
entire Special Use Permit property,
b. A seven foot chain-link fence shall be utilized for the
outer cages as shown on the plans;
c. Guard dogs shall be utilized at night within the area
between the outer perimeter fence and the shelter build-
ing.
9. Cages shall be placed outside the entrance gate to the
shelter facility to provide a holding facility for animals
dropped off at the shelter after business hours.
10. The landscape plan shall conform to the recommendations of
the Soil Conservation Service as outlined in a Conservation
Plan dated October 22, 1976, which includes seeding recom-
mendations and windbreak standards and specifications.
11. This Special Use Permit shall be limited to the plans sub-
mitted and governed by the development standards stated
above and all applicable Weld County Regulations. Any
changes to the Special Use Permit plans and/or development
standards shall require approval of another Special Use
Permit before such changes shall be allowed.
Hello