Loading...
HomeMy WebLinkAbout871176.tiff RESOLUTION RE: APPROVE AGREEMENT BETWEEN WELD COUNTY AND PUBLIC SERVICE COMPANY OF COLORADO AND AUTHORIZE CHAIRMAN TO SIGN WHEREAS , the Board of County Commissioners of Weld County, Colorado, pursuant to Colorado statute and the Weld County Home Rule Charter, is vested with the authority of administering the affairs of Weld County, Colorado, and WHEREAS, an Agreement between Weld County and Public Service Company of Colorado concerning electric service to the Severance Grader Shed has been presented to the Board, and WHEREAS, the terms and conditions are as stated in the Agreement, a copy of which is attached hereto and incorporated herein by reference, and WHEREAS, after review, the Board deems it appropriate to approve said Agreement. NOW, THEREFORE, BE IT RESOLVED by the Board of County Commissioners of Weld County, Colorado, that the Agreement between Weld County and Public Service Company of Colorado concerning electric service to the Severance Grader Shed be, and hereby is, approved. BE IT FURTHER RESOLVED by the Board that the Chairman be, and hereby is, authorized to sign said Agreement. The above and foregoing Resolution was, on motion duly made and seconded, adopted by the following vote on the 9th day of September, A.D. , 1987. • BOARD OF COUNTY COMMISSIONERS ATTEST: e-al wte&) WELD COU T O 0 Weld County 7rk and Recorder and Clerk to the Board Gor c , _ airman BY: yee, C.W Kirby, ro-T Deputyledunty rk d APPROVED AS TO FORM: tene R. B a tner C �17 \- eJhso County Attorney Frank mag chi i E (_ 0009 (2 ., 871176 0 Public Service PrniellatIsmee Gassy d fdJaills 422 Main Street Windsor, CO 80550 August 27, 1987 Weld County P 0 Box 758 Greeley, CO 80632 CUSTOMER: RE: CREG ##ER-33-6728 The customer contribution required to install the Overhead/Undsxgxsn4 electric line for 11538 County Road 74, Severance, Colorado is $ 289.00 This refundableinaassimbiale cost must be paid in advance of construc— tion. This price is valid until December 1, 1987 This cost represents electric service for grader shed and trailer with one service loop. The type of service provided will be permanent and will be billed on Rate Schedule E060 , which is on file with the Colorado Public Utilities Commision and is available for your inspection. This cost is contingent on see attached list I encourage you to contact me at 686-2291 to discuss the details of electric construction. Sincerely, (O/1)1113211 Dick Ogle District Marketing Representative Windsor Office Public Service Company Enclosure 871176 LLEGS) 71g Items checked !low Apply Job Name/Lot ion l / 538 it)ctr, corep7t¢ i Pouring of driveways must be delayed until after installation of electric lines. _ Landscaping must be delayed until after installation of electric system. _ Customer will be responsible for replacing existing sod, shrubs , trees, etc. , at no cost to PSCO. _ Paving must be delayed until after installation of electric system. (This normally applie in commercial areas where parking lots, etc. are to be crossed by electric lines.) _ Customer will be responsible for repairing existing paving at no cost to PSCO _ No special compaction of electric trenches will be provided; wheel tamping only. _ Estimate does not include non-refundable frost charges of $ (Maximum) _ Customer to furnish ±6" final grade prior to underground electric construction. Transform and switch cabinet locations must be to exact final grade. Curb and gutter must be instal ed prior to installation of electric facilities in cases of front lot construction. _ Any changes by the customer after construction has been done that require alterations to the underground electric system will result in additional costs to the customer. _ All areas on door sides of the transformers and/or switch cabinets are to remain free of a vertical obstructions for a minimum distance of 8' for maintenance operations. _ Water, sewer, gas, telephone, and other utilities shall not be installed under the tranformer pad. These utilities shall clear the outer edge of the transformer pad by at least 12". _ All roof drain downspouts are to be directed away from PSCO equipment to prevent damage and/or settling of PSCO facilities. Z Any change in this layout that will affect the estimate will void this estimate. PSCO engineering manhours to supply an additional estimate(s) must be paid for in advance at current engineering labor rates. _ No pad mounted transformer shall be located in front of a door or window of any building, or beneath a fire escape, or adjacent to fire escapes ground line exit, or under any overhang. A All property pins along the course of the electric extension must be in place for install- ation of electric facilities. _ Where customer backfills next to the buildings and the transformer and/or switch cabinet pad(s) are to be positioned upon this fill , the fill is to be compacted by the customer to at least equal the undisturbed original earth prior to installation of PSCO facilities. All buried utilities should have construction scheduled by the customer so that the deepest — i s installed first, the next to the deepest installed second, .and so on to decrease possibl damage by other utilities. Water and sewer services stubs must clear rear line of front lot utility easements in case of front lot construction Customer must furnish a copy of the approved final recorded plat (stamped with reception number, date recorded, etc.) before the order to install facilities will be released for construction. 871176 Gas and electric will installed in joint trench. 33— 67.2- 9 Developer will be required to install his own underground service loop. _ Developer will be required to furnish and install a CT and PT cabinet for metering. Transformers and switch cabinets located in vehicular traffic areas on private property will require steel protective posts. These are to be 7' long, 4" in diameter, set 3' deep in concrete, and filled with concrete. These are to be furnished, installed, and maintained by the customer, and so positioned as to not interfere with the door operations for the equipment. Customer must provide necessary easements for installation and maintenance of electric lines and equipment at no cost to PSCO. ' Remarks: . _ Customer must provide concrete pad for transformer support at no cost to PSCO. Pad dimensions: x __X Ditch crossing permit required from _ Estimate includes $ for permit. Railroad crossing permit required from Estimate includes $ for permit. Bureau of Reclamation permit required. City street cut permit required from Estimate includes $ for permit. County road permit required from Estimate includes $ for permit. State Highway permit required. Federal Highway permit required ?( PSCO refuses liability for damage to customer-owned/privately-owned underground utility lines (including sprinkler lines) unless such lines are accurately located and marked in the field by the owner prior to construction. In cases of rear lot electric distribution facilities, meter must be installed on front 1/3 of side wall of house or customer must provide and'install weather proof box and cover and conduit and interconnect wire for remote dial . Other contingencies: , , . Engineered by: o aZ AL Concurrence: blic`Servtce Company Owner - Dev ope 8711 s nJ*G. C A ,. / A7 co.,M 1E} 3r2 ..4 0284 CONSTRUCTION SKETCH 8W' X "' i • ill IjDA Y1 i ` -1 QF0 {/ / /{DA tit./ / £DA OF ••77 Y o ti� Al I t- vH wT z "y4_, po Yµ Q 9_ 6S D_ r 49 422 to 7 Q4 3 )13 r et 4-2445213 SG Pre.",nit Y i w6t.O CO RD 74 e C) ! ' o N U • LIZ .0:>---.........133-5750 d .. CD m 'C flr O00 r8itiHLyYo - 44 O C h s z M 0 w - a i. cn � o � O I ° Y � 4 > o 2 O Q LIJ W N W 1 U a m 0 S.J Sr ALL. 7 D. N 1 - I O kVA 7.4 ;so/140✓ 9 V ir CSP -re AN4 raft mEo- n n =NSrAe_L- Cot i- 3o Fr tote SPec. 81y - 12- O 1- 40 Fr PALE 1 - L4csi20 P¢i NFur SOFT A 13 e- 1- 2 AL T 6 T PLIA Sec a F ORDER NUMBERS DATE APPROVAL DATE MAP SEC. TWP. AGE. GRID NUMBER. NO. LP~ 4744 VER. HOR. VER HOR. C.R.E.G.S. NO. 33- /7a ' 45Y,347 ENGR. DEwrise 840,87 FEEDER D 9 LL C C py' NUMBERS / 56 O T W.O. /J.O. NO. EST. DEW.1 etc_ 'At�B.T ESTIMATED M.S.T.& T.NO. APPV'D. MAN HOURS SHEET I OF I DESCRIPTION. E xTF pros, ri Pre.1tr.Aoz-Y Ale Lin AL AA' ad =AI STALL. 5E< owl d Ally To SE2✓E NFw mErCoe POLE Ar / / S3A 6JE1 fl Co faD 74 871176 Hello