HomeMy WebLinkAbout20062528 USR # for private airstrip
April 20, 2006
Statement regarding sewage disposal for this property:
At this time there are no sanitary facilities on site. No sanitary facility is needed for
the airstrip. At the time a residence is built, a septic system will be installed by a
licensed contractor.
William A. Sny ec� ry
7104 W. 12th St.
Greeley, CO 80634
(970) 356-7451
2006-2528
Form No OFFICE OF THE ATE ENGINEER
GWS-25 COLORADO DIV, DN OF WATER RESOURCE
818 Centennial Btdn., 1313 She+,,,an St., Denver, Colorado 80203
(303)866-358',
LIC
rWELL PERMIT NUMBER 257913 _
�,'LICANT DIV. 8 WD 1 DES. BASIN 5 MD 9
APPROVED WELL LOCATION
WELD COUNTY
SE 1/4 NE 1/4 Section 29
ELEANOR B FRANSEN TRUST Township 2 N Range 62 W Sixth P.M.
2816 W 12TH ST ROAD DISTANCES FRAM SECTION LINES
GREELY, CO 80634- 2400 Ft. from North Section Line
350 Ft. from East Section Line
(970) 352-6967 UTM COORDINATES
PERMIT TO CONSTRUCT A WELL Northing: Easting:
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit
does not ensure that no injury will occur to another vested water right or preclude another owner of a vested water right from
seeking relief in a civil court action.
2) The construction of this well shall be in compliance with the Water Welt Construction Rules 2 CCR 402-2, unless approval
of a variance has been granted by the State Board of Examiners of Water Walt Construction and Pump Installation
Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-90-105.
4) Water from this well may be used for domestic purposes inside 1 single family dwelling(s), and the watering of the
owner's own large non-commercial domestic animals.
The pumping rate of this well shall riot exceed 15 GPM.
The annual withdrawal of ground water from this well shall not exceed 1.5 acre-feet.
7) The irrigated area shall not exceed 1 acre of lawn and garden.
8) Production is limited to the Laramie-Fox Hills aquifer which is located 340 feet below land surface and extends to a depth
of 635 feet. Plain casing must be installed and grouted to prevent the withdrawal of ground water from other aquifers and
the movement of ground water between aquifers.
9) The depth to the top of the Laramie-Fox Hills aquifer is approximate. To ensure the exclusion of poor quality water from
zones immediately above the aquifer, plain casing and grout shall extend through the lowermost coal and/or carbonaceous
shale that overlies the Laramie sand portion of the aquifer.
10) This well must be constructed within 300 feet of the location specified on this permit.
NOTE The ability of this well to withdraw its authorized amount of water from this non-renewable aquifer may be less than
the 100 years upon which the amount of water in the aquifer is allocated, due to anticipated water level declines.
1:ROVED
z A 4".
State Engineer
(Receipt No.0526010A DATE ISSUED 06-30-2004 13 EXPIRAT •N {; T. 06-30-2006 ,