Loading...
HomeMy WebLinkAbout20070799.tiff t """\ Form No. OFFICE OF THE STA I E ENGINEER GWS-25 COLORADO DIVISI , OF WATER RESOURCES 818 Centennial Bldg.. 1313 Sherman St., Denver. Colorado 80203 (303) 866-3581 857 WELL PERMIT NUMBER 198105 - -_ goo_ICANT DIV. 1 CNTY. 62 WD 2 DES. BASIN MD Lot: Block: Filing: Subdiv: APPROVED WELL LOCATION WELD COUNTY PLATTEVILLE ELEVATOR TRUCKING INC NW 1/4 SE 1/4 Section 7 BOX 844 Twp 3 N RANGE 66 W 6th P.M. PLATTEVILLE CO 80651- DISTANCES FROM SECTION LINES (970)785-2041 - 1700 Ft. from South Section Line 2440 Ft. from East Section Line PERMIT TO CONSTRUCT A WELL ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDmONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of the permit does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2)rhe construction of this well shall be in compliance with the Water Well Construction Rules 2 CCP 402-2, unless -pproval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved pursuant to CRS 37-92-602(3)(b)(I) and the policy of the State Engineer dated 4/9/85 for appropriation of ground water tributary to the South Platte River system. 4) The use of ground water from this well is limited to drinking and sanitary facilities as described in CRS 37-92-602(1)(c), for a commercial business. Water from this well shall not be used for lawn or landscape irrigation or for any other purpose outside the business building structure. 5) The total depth of this well shall not exceed 60 feet or the first confining clay/shale series encountered, which corresponds to the base of the alluvial aquifer. 6) The maximum pumping rate shall not exceed 15 GPM. 7) The maximum annual amount of ground water to be withdrawn shall not exceed 1/3 acre-foot (108,600 gallons). 8) Approved as the only well on a site of 1 acre described as part of the NW1/4 of the SE1/4 Section 7, Township 3 North, Range 66 West, 6th Principal Meridian, more particularly described in the attached exhibit A. 9) The return flow from the use of the well must be through an individual waste water disposal system of the non-evaporative type where the water is returned to the same stream system in which the well is located. The maximum consumptive use of ground water shall not exceed 10 percent. 10) A totalizing flow meter must be installed on this well and mai fined in good working order. Permanent records of all diversions must be maintained by the well owner (reco ast's nua)ly) and submitted to the Division Engineer upon request / J/ /P !;'V (. 11) This well shall be constructed not more than 200 feet from the location spe iffed bit t4ii plr,Orrpt. r- • !(' ^te: To insure a maximum productive life of this well, perforated casin oat t 1e.set throuahttl entire producing interval of the approved zone or aquifer indicated above. lF ��� 2007-0799 'PROVED p( :AN 1 A ! , • State engineer / By aceipt No. 0401419 DATE ISSUED SEP 1 2 1996 EXPIRATION DATE SEP 1 2 ,192 ,tvi NG. STATE OF COLORADO - For Office Use only -10 OFFICE OF THE STATI .JGINEER 2 818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203 (303) 866-3581 • FOR INSTRUCTIONS, SEE REVERSE SIDE STATEMENT OF BENEFICIAL USE WELL PERMIT NUMBER 1 9 8 1 0 5 NELL OWNER JAME(S) Platteville Elevator Trucking Inc . Mailing Address Box 844 ;)ty, St. Lip Platteville , Co . 80651 'hone ( 970 ) 785-2041 YELL LOCATION: COUNTY weld OWNER'S WELL DESIGNATION (Address) (City) (State) (Zip) Nw 1/4 of the S r, 1/4, Sec. 7 Twp. 3 Ei N. or S., Range 66 C E. or El W. 6 P.M. 'istances from Section Lines 1 7 0 0 Ft. from ❑N. or O S. Line, 2440 Ft. from U E. or❑ W. Line. she well is being used for the following purpose(s): Drinking & sanitary facilities for commercial business Dater from the well was first used beneficially nder this permit number, for the above described purposes on 9-26-96 _ 19 'o not report a date which is before the issued date of this permit) he pumping rate claimed is 15 gallons per minute. he average annual amount of water diverted is 1 /3 acre feet.-1e land area irrigated (watered) by water from this well is: 1 .:.t Acres or I Square feet, (Number) ?scribed as: 1W 1 /4 ,of t11e S71 /4 , Seq. 7 , Twp. 3 N . Rnc , 66 5 PM (Legal uescripuon) as Subdivision Lot(s) Block Filing/Unit 'ell drilled by: R & R Well & Puma Inc . Lic. No: 857 imp installed by: R & R Well & Puma Inc. Lic. No: 857 eter Mfg. by Master meter Serial No.: 1 8 9 4 0 1 4 Date Installed: 10-3-96 . (we) have read the statements made herein, know the contents thereof, and state that they are true to my (our) Zowiedge. [Pursuant to Section 24-4-104 (13)(a) C.R.S., the making of false statements herein constitutes perjury the second degree and is punishable as a Class 1 misdemeanor.] Name/T itle (Please type or print) Signature Date latteville Elevator Trucking ^y . 10-5-96 FOR OFFICE USE ONLY • State Engineer By Date Court Case No. Div. Co. WD Basin MD Use I r. FORM N0. 1 PUMP INSTAI l ATI( ' AND TEST REPORT For Office Use only Gus-32 11/9 STATE OF COLORADO, OFFICE OF THE STATE ENGINEER 1. WELL PERMIT NUMBER 19 8 1 0 5 a OWNER NAME(S) Platteville Elevator Truckino Inc . Mailing Address Box 8 4 4 City, St. Zip Platteville , Co . 80651 Phone (970 ) 785--2041 3. WELL LOCATION AS DRILLED: Nw 1/4 S7 1/4, Sec. & Twp. 3 N , Range FF w • DISTANCES FROM SEC. LINES: 1 7 pc) ft. from Fo l i t-ti Sec. line. and ?it a Q ft. from 7,,IF r Sec. line. (north or south) feast or vest) SUBDIVISION: LOT BLOCK FILING(UNIT) . • STREET ADDRESS AT WELL LOCATION: L PUMP DATA: Type Submersible Installation Completed 9-25-96 Pump Manufacturer Goulds Pump Model No, 1 8GS07 . Design GPM 1 5 at RPM 3 6 0 0 . HP 1/4 . Volts 230 , Full Load Amps 6 - 9 Pump Intake Depth 50 Feet, Drop/Column Pipe Size 1 1 /4 Inches, Kind PVC Sch 80 ADDITIONAL INFORMATION FOR PUMPS GREATER THAT 50 GPM: TURBINE DRIVER TYPE: r Electric I Engine I ,1 Other Design Head feet, Number of Stages , Shaft size - inches. . OTHER EOT1-IER EQUIPMENT: A' e Installed Yesl No, Orifice Depth ft. . Monitor Tube Installed Ell Yes x• No, Depth ft. _ . Meter Mfg. Meter Serial Nc. Meter Readout [ I Gallons. I I Thousand Gallons, U Acre feet, El Beginning Reading TEST DATA: f J Check box if Test data.is submitted on Supplemental Form. Date 9--2.5_96 Total Well Depth r 0 Time 1 : 00 PM . Static Level 7 h Rate (GPM) 1 Date Measured o_ 1 a_a R Pumping Lvl. 2 2, DISINFECTION: Type P74 Amt. Used ; u Water Quality analysis available. H Yes F.- No Remarks 1 I have read the statements made herein and know the contents thereof, and that they are true to my knowiedge.; [Pursuant to Section 24-4-104 (13)(a) C.R.S., the making of false statements herein constitutes penury in the second decree and is punishable as a class 1 misdemeanor.} • Ot\ 1,CTOR p & r well & Perin Inc . Phone (970 ) 3.53-3 1 1 8 Lic. No. 85 7 ailing Address a _(-)_ R.nv 577 • rrnnl Co . 80632 me/Title (Please type or print) v Signatu�re�, Cate )t:t EP Glenn A . Clement �-'j f� �/� 9 2;-96 TELL CONSTRUCTION AND PUMP INSTALLATION BY THE WELL OWNER • You may construct the well and/. .nstall the pump yourself if the well is enti. for your own use, is on property you own, and is constructed or pump equipment is installed with equipment owned and operated by you. It is your responsibility to complete and submit the Well Construction and Test Report, Form Number GWS-31 and/or the Pump ^'1 Installation and Test Report, Form Number GWS-32. These forms are available from our offices. The well must be - constructed and the pump installed in accordance with the well construction standards of the State Board of Examiners of Water Well Construction and Pump Installation Contractors. THE WELL CONSTRUCTION AND PUMP INSTALLATION RULES STATE THAT ALL WELLS OF THIS TYPE MUST BE DISINFECTED AFTER CONSTRUCTION AND AFTER PUMP INSTALLATION. 11-IE WELL CONSTRUCTION AND PUMP INSTALLATION RULES ARE AVAILABLE FROM DIVISION OF WATER RESOURCES OFFICES FOR A FEE OF $3.00. The rules cover well construction, pump installation, disinfection, abandonment and contractor licensing regulations. If you are constructing your own well or installing pumping equipment, it is recommended that you obtain a copy of these rules for reference. • YELLS TO BE PLUGGED AND ABANDONED MUST BE PLUGGED IN ACCORDANCE WITH RULE 11 (SHOWN 3ELOW) OF THE WELL CONSTRUCTION AND PUMP INSTALLATION RULES. A WELL ABANDONMENT REPORT, 'ORM NUMBER GWS-9 MUST BE SUBMI I I tD TO CONFIRM THE PLUGGING OF THE WELL THIS FORM IS ,VAILABLE FROM OUR OFFICES. IULE 11 ABANDONMENT STANDARDS 1.1 General 1.1.1 The plugging and sealing of all wells and test holes is necessary to prevent contamination of groun water and the migration of water through the unused borehole. It is the ultimate responsibility of the wel owner to have a well properly plugged and abandoned. The well construction contractor is responsibl for notifying the well owner of the plugging and abandonment requirement pursuant to this Rule 11. 1.12 Persons authorized to install pumping equipment may plug and abandon wells which do not require th removal of casing from more than one aquifer or the ripping or perforating of casing opposite confinin layers. 1.1.3 All materials used for backfilling shall be clean, free from contaminants and chemically inert. 1.2 Unconfined Wells-Wells completed into unconfined aquifers shall be abandoned by filling with eithe on-site materials, clean sand or gravel to the static water level, then with chemically inert materials t the ground surface. A permanent watertight cover shall be installed at the top of the casing. The casin may be cut off up to five (5) feet below ground level provided the watertight cover is welded o permanently attached to the top of the casing and the hole is back-filled to the land surface. .21 Cathodic protection holes, dewatering wells, horizontal drains, monitoring and observation holes percolation holes, piezometer holes, sump pumps and test holes shall be abandoned either pursuan to Rule 11.2 or by removing all casing which was installed and by filling the hole(s) with drill cuttings o chemically inert materials to within five (5) feet of the ground surface. The top five (5) feet of the hol shall be sealed with materials equal to or less permeable than the top foot of the surrounding soils. .3 Confined Wells .3.1 Wells which were constructed through more than one aquifer shall be abandoned by placing a gro plug at the confining layer above each aquifer. If records do not show that the casing opposite eac confining layer has been grouted when originally installed,the casing shall be either completely remove from the hole, or perforated or ripped opposite such layer prior to placing the grout plug. No plug shal be less than twenty (20) feet in length. .3.2 The well casing except for the grout plug intervals shall be completely filled to the land surface wit chemically inert materials. A watertight cover will be permanently welded or attached to the top of th casing. The casing may be cut off up to five (5) feet below land surface provided the watertight cove is welded or permanently attached to the top of the casing and the hole is backfilled to the land surface 1 ,-- FORM NU i WELL CONSTRUC . .0N AND TEST REPORT For Office Use only 0ws3! roi94 STATE OF COLORADO, OF, ..:E OF THE STATE ENGINEER 1.WELL PERMIT NUMBER 198105 2 OWNER NAME(S) plat Levi 1IA 1 vator Truckira Inc, Mailing Address Box 8 a 4 City, St. Zip P1 atteville , Co . 80651 Phone ( 970 ) 785-2041 3. WELL LOCATION AS DRILLED: NW 1/4 SE 1/4, Sec. 7 Twp. 3 N , Range 66 W DISTANCES FROM SEC. LINES: 1 7 0 0 ft. from South Sec. fine. and 2440 ft. from Ea s t Sec. line. OR (norarbr sown) - ieasz or oresa SUBDIVISION: LOT BLOCK FILING(UNI7) . STREE if ADDRESS AT WELL LOCATION: 4. .GROUND SURFACE ELEVATION ft. DRILLING METHOD Rotary . DATE COMPLETED 9-18-96 . TOTAL DEPTH 60 ft. DEPTH COMPLETED 60 ft. 5. GEOLOGIC LOG: 6. HOLE DIAM. (in.) From (ft) To (ft) Depth Description of Material(Type,Size, Color,Water Location) 8 7/8 0 60 n-2 0p 504T 7-7 1= 7.-n _ clay Sr rid . 7-12 gPnd/a,-av�1 "2- 37 ;Ilk s r r,d c1 a y 7. PLAIN CASING 7—c7 h:rt,vc1 �„ OD (in) Kind Wall Size From(ft) To(ft) 7_60 �hr1 . 6 5/8 Steel . 250 +1 20 5 PVC . 277 20 d0 PERF. CASING: Screen Slot Size: . 035 5 PVC . 277 40 60 • 8. FILTER PACK: 9. PACKER PLACEMENT: Material Gravel Type Size 7 /8 Interval 20-6 0 Depth 10. GROUTING RECORD: Material Amount Density Interval Placement EMARKS: Cement 4 R3. 1 . 86 0-20 POurbd DISINFECTION: Type HTH Amt. Used WELL TEST DATA: 1 I Check box if Test Data is submitted on Form No. GWS 39 Supplemental Well Test. TESTING METHOD Bailed Static Level 26 _ ft. Date/Time measured 9- 1 8-9 6 , Production Rate 15 gpm. Pumping level 28 ft. Date/Time measured 9- 1 8-9 6 , Test length (hrs.) 3 . Rt!' rks I ha... read the statements made herein and know the contents thereof, and that they are true to my knowledge. (Pursuant to Section 24-4-104 (13)(ai C.A.S.,the making of false statements herein constitutes perjury in the second decree and is punishable as a class 1 misdemeanor.] )NTPACTOR R & R Well & PUmp Inc. Phone (97J 353-3 1 1 8 Lic. No. 857 . 3ilingAddress P.O . Box 577 Greeley , Co. 80632 me/Title (Please type or print) Signature,-., _ Date � ____----,--- -,-7-:-----;:C f R Glenn A . Clement �i - 9-27-96 I El TRI-COUNTY HEALTH DEPARTMENT g, PercolationTest Result Form Hole Length of Water Depth Water Depth Drop In Percolation Hole Depth Interval @ Start • @ End Water Level Rate @ Final No. (in.) (min.) of Interval of Interval (ft.) Interval (ft.). (ft.) (miniin.) 4 2 ¢ 2; 10/0 0,3 / L; LP /A O, 4-U L; 3 4717 Pi'7 Z/.40/2 o,b� 2,'9C /7 C,4, 7 5/.04,762 0,77 0r77 0,05- 3,`"0/Cv 0,77 _ 1,/, 7 J So / 0 _ a;4- / O o,40 // 0,45 /c' o,5;.-- /h O,5,3 /c? o, 64- 0,7c) - 1,D6 • _i_c_i_H 0, 7e / /3,?e ( ,1 So 7d O,3 L. /U o.S0 /r' 4, G 7 /9 0.7.Z- /42 O,86 / /2 0,p¢ / .jz. o/os //} /,a2— /4 4-z AVERAGE PERCOLATION RATE /7--r 6( MIN./PER/INCH. 'Field Notes shall be recorded on this form or in this format; typed copies of field records may De submitted on this form. A four hour test must be conducted unless (a) water remains in the hole after the presoak in ✓hich case one 30 min. interval is sufficient, (b) the first 6" of water seeps away in <30 linutes in which case a one-hour test of 6 - 10 minute time intervals may be used, (c) the test s being conducted in sand in which case a one-hour test of 6 - 10 minute time intervals may -� e used, (d) three successive water level drops do not vary by more than 1/16 inch in which ese a two hour test may be conducted. 1. __ . .- . FE w TRY-COUNTY HEALTH DEPARTMENT Percolation Test Result Form Hole Length of Water Depth Water Depth Drop In Percolation Hole Depth Interval @ Sled ' @ End Water Level Rale @ Final No. (in.) (min.) of Interval of Interval , (ft.) Interval (ft.) / 30 /O 0,64- /v v, 7a.- 7 a 0, 75 70 o,8y • ., ri,9/ ___Le__ 0,97 /O? z-%c6 /L) 1 / 7 • Z-¢ /0 r,,34- / O 0,4-0 _____U2_ 0,4.1- r /U o..5-2 /6' x,57 //J or W t J.? . or.5' / /G' 0,77 G v . //, 2I /e9 a,.74 0, 52 /O ".72 /r? v.86 /0 C, 94 ii> /, 09 I, /7 (r). 07 /9 / . /7 912r AVERAGE PERCOLATION RATE MIN./PER/INCH. 'Field Notes shall be recorded on this form or in this format; typed copies of field records may be submitted on this form. *A four hour test must be conducted unless (a) water remains in the hole after the presoak ir, which case one 30 min. interval is sufficient, (b) the first 6" of water seeps away in <30 mutes in which I'case a one-hour test of 6 - 10 minute time intervals may be used, (c) the test eing conducted in sand in which case a one-hour test of 6 - 10 minute time intervals may be used, (d) three successive water level drops do not vary by more than 1/16 inch in which case a two hour test may be conducted. WELD COUNTY HEALTH DEPARTMENT 1517 16TH AVENUE COURT, GREELEY, CO 80631 (970) 353 -0635 EXT 2225 FAX (970) 356-4966 'ermit # : SP-9600314 Sec/Twn/Rng: PERMIT )ermit Type : RNEW C.corsercial,. R.residential • NEW, REPair, VauLT Applied: 06/11/1996 Parcel No: 1211 07 Expires: 06/06/1997 OZ ,p, Location: PrvDTvn/ 5T N. O^ 3D CN H Y 85 07-03 -66 Legal Desc : • APPLICANT PLATTEVILLE ELEVATOR TRUCKING CO Phone : (970) 785-4416 PO BOX 844 , PLATTEVILLE CO 80651 A OWNER P��I T ELEVATOR TPt _frNCC? iJn& 1/1, ' Phone : (970) 785-6416 PO BOX 84 _ TEV LL 80651 1-3— Description: OFFICE TRAILER :ommercial (Y/N) : Y Residential (Y/N) : N Acres : 1 . 00 amber of Persons : 7 1 Basement Plumbing (Y/N) : nber of Bedrooms : flip Bathrooms-> Full : 1 3/4 : 1/2 : :er Public (Y/N) : Utility Name : Private (Y/N) : Y Cistern (Y/N) : Well (Y/N) : Y Water Permit No: 'ercolation Rate : I2 e67 Limiting Zone: 3 ft kin Desc : 5rcLue- ( Ground Slope : Dir: _ Soil Suitable (Y/N) : N neeer Design Req' d (Y/N) : Y In 100 Yr Flood Plain (Y/N) : ,e application information supplied and the on-site soil percolation data the following mini= installation specifications wired: Septic Tank : (000 gallons, Absorption Trench sc. ft . or Absorption Bed {/I gS sq. ft . ddition, this permit is subject to the following additional terms and itions : 'ri$-(rvcl «cccia4., \.o (2.. )/H ctiez/L dcSjch. NOTICE :*nit is granted temporarily to allow construction to commence. This permit may be revoked or suspended b_v the Weld County )epartment for reasons set forth in the weld County individual sewage disposal system regulations including failure to meet 0 or condition imposed thereon during temporary or final approval. The issuance of this permit does not constitute .on by the department or its employees of liability for the failure or inadequacy of the sewage disposal system. -mit is not transferable. Before issuing final approval of this permit the Weld County Health Department reserves the right e additional terms and conditions required.to meet our regulations on a continuing basis. Final permit approval is nt upon the final inspection of the completed system by the Weld County Health Department. ^' Environmental Specialist Date • WELD COUNTY HEALTH DEPARTMENT 1517 16TH AVENUE COURT, GREELEY, CO 80631 (970) 353 -0635 EXT 2225 FAX (970) 356-4966 Permit # : SP-9600314 Sec/-U1:1 g: Status : BOH-HOLD Permit Type : RNEW C-commercial, R-residential . NEW, REPair, VauLT Applied: 06/11/1996 Parcel No : 1211 07 Issued: 08/05/1996 43o2 Rlfw([ 4C Oo j! Finaled: Location : -=t! INGf_cb0 . T N--OF.D 3C_ aN RWY C3 07-03 -66 Legal Desc : APPLICANT PLATTEVILLE ELEVATOR TRUCKING CO Phone : (970) 785-6415 PO BOX 844 , PLATTEVILLE CO 80651 �- *•-� vtT T ^ t'T RVATnR TRCCI C OWNER E �).j i Phone : (i7-(J) /85-b477-3 - PO BOX 844 , PLATTEVILLE CO 80651 Description: OFFICE TRAILER Commercial (Y/N.) : Y Residential (Y/N) : N Acres : 1 . 00 • Number of Persons : 7 Basement Plumbing (Y/N) : umber of Bedrooms : Bathrooms-> Full : 1 3/4 : 1/2 : a Public (Y/N) : Utility Name : tee Private (Y/N) : Y Cistern ( f/N) : Well (Y/N) : Water Permit No : Percolation Rate : 12 . 6 Limiting Zone : ft C6 in Desc : grave ( Ground Slope : Dir: Soil Suitable (Y/N) : N gineer Design Req' d (Y/N) : Y In 100 Yr Flood Plain (Y/N) : aimum Installation Septic Tank : 1000 gal Absorption Trench: s4. ft . Absorption Bed: 185 sq. ft . tual Installation Septic Tank: ( eo gal Absorption Trench: sq. ft . Absorption Bed : 4,0 sq. ft . NOTICE issuance of this permit does not imply compliance with other state, county or local regulatory or building requirements, nor it act to certify that the subject system will operate in compliance with applicable state• county and local regulations ted persuant to Article 10, Title 25, CRS as amended, except for the purpose of establishing final approval cf installed em for issuance of a local occupancy permit persuant to CRS 1973 15-10-111 (21 . permit is not transferable. The Weld County Health Department reserves the right to impose additional terms and conditions ired to meet our regulations on a continuing basis. Final permit approval was contingent upon the final inspection of the Jetted system by the Weld County Health Department. � �.�\A"o{L X Environmental Specialist Date • Tri-County Health Department Percolation Test and Soils Data Form Property address Le:al description Property Owner Name /72- T7LL=C7/L L //` L 'C'K /AZ0 . Address /--%/71 i r/=' L// Phone Note: • Percolation Test Pone, Site Plan and Grain Size Distribution Curve of the Sample must be submitted with this form. • For all Lots <5 acres the site plan must indlude the entire lot. Test locations must • be accurately tied to lot corners or other permanent markers. • `Saturation and Swelling Groundwater: • Encountered @ 7F feet. • Smeared surfaces removed: l Ycs No • Estimated depth to maximum seasonal • Sand or gravel added: Ycs �No water table if not encountered in profile: • Date and time presoak water added: ._ /227/11// • Is area believed to be subject to seasonal fluctuations which could result in a seasonal water table within S' of surface?• Amount ofpresoak water added (gallons): Yes • No /!/ Slope determination in absorption area: / % to • Date and time percolation the /V (direction) 5/ &% 1/7L, Bedrock: • Encountered@ 7feet. • Did water remain in hole after die overnight swelling • Estimated depth if not encountered in period: profile: Hole 1 Ycs v No //./c/e ¢ Type of bedrock: Sandstone Hole 2 _Ycs v No /I>/e j = ALA • Hole 3 Yes 1-"No ._!L Ciaystone Silutone Percolation Rate Measurement - Other Percolation Rate(min./in.) Hole I /„'; Ar • Is bedrock fractured or weathered?/-/ck-� /Z . Hole 2 /1, 9 G/v/e 5 /Ye .4b' Hole 3 .L .2Yes No Nom'/ L / L' Avera_e /1 • Is bedrock believed to be permeable? (Pert rate <60 min/in.) _Yes __No I'ufile Hole Information (Cont.) 'Soils must be classified using Ur, cd System ASTM D2487) Profile Hole Log 0 1 -2 /// • 4 • _ 5 SF C 6 7 • —9 —10 • Certification I certify that the above information is..corect and complete to the best of my knowledge and that all tests v.ere performed in accordance with the provisions of Tri-County Health Depanmcnt Regulation I.xS by myself or under my supervision. Original Signature Date ALPHA ENGINEERING CO. Company Name Box 392 , Fort Lupton, CO 80621 Address 303-573-5186 '12330 (lone - - C Original Seal Set Ey: ALPHA ENG; 303 857 3707; Sap-21 -3 2:54PM; Paq 1 ; ALPHA ENGINEERING LAND DEVELOPMENT PROPERTY SURVEYS 617 FIFTH STREET --- P.O. BOX 392, FORT LUPTON, COLORADO 80621 PHONE: 303-857-2308 or 303-857-2010, FAX: 303-857-0707 E-MAIL:ALPFFASURVEYING@AOL.COM September 21, 2000 Weld County Health Department 1515 N. 17th Ave Greeley, CO 80631 Ph: 303-857-4334 Fax: 970-304-6411 RE: Inspection of Septic System for Platteville Trucking, 16302 Highway 85, r Platteville, Weld County, Colorado. ESP-96003141 Dear Official: This office inspected the above described Septic System in or about August 1996 and found it to be substantially constructed in compliance with Alpha Engineering Plan # 7-3N6-06. Sincerely, - \r to%; �5Z� r. /1„,....f."7/.. ems': 12330 Cecil R. Crowe, PE and LS 12330 D:DATS5\WP\SSEPl73N6PLTVLTRVCKINGSEP.fld It � f Hello