CENTRAL WELD COUNTY WATER DISTRICT
July 20,2005
Melvin Dinner,P.C.
822 7c'Street,Suite 540
Greeley, CO 80631
RE: Water Service to Petro-Canada Resources(USA)Inc.Property
Dear Mr. Dinner:
This letter is in response to a request for water service to serve the following property described as
follows;
Part Section 18,Township 4 North,Range 64 West,Weld County,Colorado.
Water service is presently available to the above described property by tap number 2001 located at
Weld Co. Rd. 46 between 49 & 51. Additional water service can be made available to this
_ property, provided all requirements of Central Weld County Water District, Northern Colorado
Water Conservancy District and the Bureau are satisfied. This property has been petitioned into
Northern Colorado Water Conservancy District.
New service will have to meet the criteria stated in the Water Shortage Contingency Plan adopted
by the Board on June 20, 2002. Central Weld County Water District requires that contracts be
consummated within one (1) year from the date of this letter or this letter shall become null and
void unless extended in writing by the District. Please contact the Central Weld office for thither
information about water service. Due to the rapid cost increase of raw water, existing tap fees may
not apply for water service to this property. The District will not notify, by separate letter, any
prospective landowners or land purchasers of tap fee or line extension cost increases. The cost of a
tap fee and/or improvements will have to be paid in advance to the District by the prospective
customer in accordance with District policy.
If you have any questions regarding the above,please contact this office.
Sincerely,
CENTRAL WELD COUNTY WATER DISTRICT
%C4S4anagn .
•
2233 2nd Avenue - Creaky,Colorado 80631 - Phone(970)352-1254 • Fax'(970)353-5$e
2006-3002
APR 0 .j 2006
Northern
Colorado
Geotech
March 30, 2006 2956 29th Street, Unit 21
Greeley,Colorado 80631
Phone: (970)506-9244
Fax: (970)506-9242
Petro Canada
1099 18th Street, Suite 412
Denver, Colorado 80202
Attn: Susan Miller
Re: Percolation Test and Septic System Design Revision
Weld County Roads 46 and 49
Northern Colorado Geotech Project No. 009-06
The original septic system design was for 15 day workers. This has been revised for 20 field workers
(at 5 gallons/day) and 2 day workers (at 15 gallons/day). This is still within the 375 gallons/day of the
original septic system design so no changes will be necessary.
If you have any questions or if we may be of further assistance, please do not hesitate to contact us at
(970) 506-9244.
'
Sincerely, " "- ,
--
NO ERN CO O' ' • cz
.::
'
Doug ea re . •..............`
.... ,
President
cc: Addressee (2)
WCHD - Pam Smith (1)
Northern
Colorado
Geotech
January 26, 2006 2956 29th Street, Unit 21
Greeley, Colorado 80631
Phone: (970)506-9244
Fax: (970) 506-9242
Apex Petroleum
6123 Buffalo Run
Littleton, Colorado 80125
Attn: Shane
Re: Percolation Test and Septic System Design
Weld County Roads 46 and 49
Northern Colorado Geotech Project No. 009-06
Northern Colorado Geotech has performed a soil percolation test and septic system design for the
above referenced site southeast of LaSalle, Colorado. The soil at the site is silty clayey sand that is
underlain by sandstone/siltstone bedrock at a depth of approximately 6 feet. The site will be used for
commercial activities, therefore an engineered septic system is required for the site and has been
attached with this letter.
If you have any questions or if we may be of further assistance, please do not hesitate to contact us at
(970) 506-9244.
Sincerely,
NO THERN COLO O GEOTECH
Ai,
Dou Lea re , P.G. i``• .✓
President
R i pd by:
ary G. Weeks,,P.E.:
ice President , -
c: Addressee (4).
)
) ,
WELD COUNTY ROAD 46
d3
•
; I • • a.
c
. r:
` M :i : Nof Ho:2Nn.3 ,< • PROFILE
Ai 5+ 4 `�—BORING
I
l
` ' BORING LOCATION PLAN
?s - N PROPOSED SEPTIC SYSTEM
WELD COUNTY ROADS 46 AND 49
WELD COUNTY,COLORADO
FOR APEX PETROLEUM
Northern ° No.
009-06
Colorado Scale: 1•=zoo
Geotech Date: ,-2s-os
2956 29th Street,Unit 21 Project No.
Greeley,Colorado 80631 DML
Phone: (970)506-9244
Fax: (970)506-9242 Figure No.
•
LOG OF PROFILE BORING Sheet 1 of 1
CLIENT ARCHITECT/ENGINEER
Apex Petroleum
SITE Weld County Road 46 and 49 PROJECT
Weld County, Colorado Proposed Septic System
SAMPLES TESTS
0
z be
-J z 0 w z z CC ADDITIONAL
O �. w Ce w 0 z w DATA/ '
E = w ≥0 w a w REMARKS.
0a m r, D:w y ca
0 O¢ >w z0
Surface Elev.: 97.3 ft. 0 o wz 2 ?? 2 Ea II-.
6"TOPSOIL •
;. v
0.5 SILTY CLAYEY SAND l • —• .:
Tan, dry to moist, medium dense
•
•
•
•
•
-
•
6.0 91.3 -
WEATHERED SANDSTONE/SILTSTONE
Tan to grey, moist,soft
29 1 SS 12 21
I I
8.0 89.3
BOTTOM OF BORING
WATER LEVEL OBSERVATIONS Northern STARTED /1 /06 FINISHED 1/11/06
WL None W.D. olorado
Geotech DRILL CO. Drilling Eng DRILL RIG CME-55
WL None A.B. 2956 29th Street, Unit 21 LOGGED BY DBC APPROVED DML
Greeley,Colorado 80631
g When Checked 2 Days A.B. Phone: 970-506-9244
Fax: 970-506-9242 NCG PROJECT NO. 009-06
SEED OR SOD TOP OF BED SOON
AFTER CONSTRUCTION TO CONTROL
EROSION AND AID EVAPO-TRANSPIRATION
EXISTING GRADE SLOPE FOR POSITIVE DRAINAGE
COVER 1 —APPROVED BACKFILL SPEC.7— ivZ
SPEC.6
2
—WASHED GRAVEL--
Q--Heal— LEACHLINE
SPEC.5
SPEC.4 SPEC.5 1c le
SCARIFY EXISTING SOIL
PRIOR TO FILL PLACEMENT
SILTY CLAYEY SAND SILTY CLAYEY SAND
3.0"TYP 6.0"MAX TYPICAL D
z
2
•
SANDSTONE/SILTSTONE BEDROCK
SEPTIC SYSTEM CROSS-SECTION
SEPTIC SYSTEM DESIGN
PROPOSED COMMERCIAL SEPTIC SYSTEM
WELD COUNTY ROADS 46 AND 49
WELD COUNTY,COLORADO
FOR APEX PETROLEUM
Project No.
Northern 009-06
INI0oiorado Scale. _,•
Geotech Dale: 1-25-06
2956 29th Street,Unit 21
Greeley,Colorado 80631 Project Mgr. DML
Phone: (970)506-9244
Fax (970)506-9242 Figure No. 2
Apex Petroleum •
Weld County Roads 46 and 49
Northern Colorado Geotech Project No.009-06
SEPTIC SYSTEM DESIGN CRITERIA
1. Percolation Test Results:
Test Boring No. Percolation Rate (min/in)
1 44
2 30
3 20
4 44
5 40
6 60
Design Rate, t= 40 minutes per inch
2. Min Bed Area: Q = max 15 day workers x (15 gal/person/day) = 225 gallons/day
225 gallons/day x 150% = 375 gallons/day
Area = (Q x 't/ 3.5) 1.3 = 881 square feet of absorption bed
SEPTIC SYSTEM DESIGN SPECIFICATIONS
1. Septic Tank—Minimum = 150% of 30 hours avg flow = 1.5 x (225 x 1.25) = 1,000 gallons
2. Bed Area - 881 square feet
3. Distribution Box- Installed level to provide equal distribution of effluent.
4. Gravel - 12 inches (minimum) clean gravel graded from %" to 2W in size extending from at least 2
inches above the top of the leach line to at least 6 inches below bottom of leach line for the full
width of absorption bed.
5. Leach Line - 3 or 4 inch perforated PVC placed at 6'0" on center and laid level to provide even
distribution of the effluent over the entire bed.
6. Cover - Untreated building paper or straw placed over the gravel to minimize infiltration of fines
into the gravel and pipe during backfilling operation.
7. Backfill - 12 inches (minimum) to 24 inches (maximum) of on-site soil or imported wicking sand.
The top 4 inches shall be a select organic topsoil.
GENERAL NOTES
1. All construction shall be in compliance with Weld County Health Dept and State regulations.
2. Any deviation from the plan must be approved by WCHD and/or Northern Colorado Geotech prior
to construction.
3. All parts of the field shall be located the minimum distances from land features including 100' from
any well, pond or ditch, 20' from all dwellings and 10' from all property lines.
4. The system shall be inspected by WCHD and/or Northern Colorado Geotech during critical
phases of construction.
5. Positive drainage shall be provided to minimize surface runoff from entering the system.
6. The top of the field shall be seeded or sodded with low-water demand vegetation to control
erosion and aid evapo-transpiration. Large trees or shrubs should not be planted within 6 feet of
the field.
7. The completed leach field should not be paved or driven over at any time.