Loading...
HomeMy WebLinkAbout20082736.tiff 14C F EARTH ENGINEERING March 5, 2007 CONSULTANTS, INc. Weld 45-Acre, LLC c/o Team Engineering 3468 Shallow Pond Drive Fort Collins, CO 80528 Attn: Mr. Jeff Couch, P.E. Re: Pavement Design Moorea Manor Weld County, Colorado EEC Project No. 1072030 Mr. Couch: As requested, Earth Engineering Consultants, Inc. (EEC) personnel have reviewed the • preliminary geotechnical subsurface exploration information for the referenced project (Church and Associates, Inc. dated November 27, 2002 and titled "Preliminary Percolation Test Report, Proposed Moorea Manor North") with regard to providing pavement section recommendations for the referenced development. Results of our review and recommendations concerning pavement sections for use on the roadways at Moorea Manor based on available information are provided with this report. Moorea Manor is located southwest of Platteville, north of County Road 24% on the west side of County Road 21'1. The existing portion of the development includes six (6) lots accessed by Harpenden Lane, an existing gravel surfaced roadway. We understand Moorea Manor North will include eight (8) residential lots with access for four (4) lots directly off of Harpenden Lane and, for four (4) lots, access from a new cul-de-sac off of Harpenden Lane. We understand Harpenden Lane surfacing includes approximately 8- inches of aggregate base/road base. Both roadways will be improved to asphalt surfaced roadways. Three (3) borings were advanced for the Moorea Manor North development during the • exploration completed by Church & Associates, Inc. The borings were advanced to 4396 GREENFIELD DRIVE EXHIBIT WINDSOR, COLORADO 80550 (970) 224-1522 FAX (970) 663-0282 /0 2008-2736 Earth Engineering Consultants,Inc. • EEC Project No. 1072030 March 5,2007 Page 2 depths of approximately 20 to 25 feet. Topsoil was encountered to one foot below ground surface and was underlain by brown to light brown clayey silty sand and extended to the bottom of borings TH-1 and TH-2. Weathered claystone with sandstone was encountered approximately 11 feet below existing ground surface in TH-3. Ground water levels were observed at approximately 19, 7 and 16 feet below ground surface. Laboratory testing performed by Church and Associates Inc. indicates the roadway subgrades consist of non-plastic silty clayey sand. The sand material exhibited low swell potential with variation on moisture content. ANALYSIS AND RECOMMENDATIONS Pavement Subgrade • In the area of the proposed roadway, all existing vegetation and topsoil should be removed. After stripping, the pavement subgrades should be scarified to a depth of at least 9 inches, adjusted in moisture content and compacted to at least 95% of standard Proctor maximum dry density. The moisture content of the scarified soils should be within±2% of standard Proctor optimum moisture at the time of compaction. It is our opinion a composite asphalt (HBP)/aggregate base (ABC) pavement section could be constructed directly on the conditioned clayey silty sand subgrades. We expect the existing roadway subgrade in the area of the existing roadway could be used. Pavement Sections We expect low volumes of lightly loaded automobile traffic with an occasional trash truck or heavier truck traffic will use the roadways. A Hveem stabilometer R-value of 5 was assumed for the clayey silty sand subgrade soils. Based on the exploration and testing performed by Church and Associates, Inc., we • recommend the pavement sections for the roadways comply with the Weld County minimum pavement sections of 4-inches of hot bituminous pavement (HBP) underlain by • Earth Engineering Consultants,Inc. EEC Project No. 1072030 March 5,2007 Page 3 6-inches of aggregate base course. At the existing roadway, we recommend 4-inches of hot bituminous pavement (HBP) be placed on existing shaped and leveled aggregate road base. The HBP should be grading S (75) with PG 58-28 oil. The aggregate base should be Class 5 or Class 6 base. Positive drainage should be developed across and away from the pavements to avoid wetting the pavement subgrades. The pavement subgrades allowed to become wetted subsequent to construction can result in premature failure of the pavement section. GENERAL COMMENTS The analysis and recommendations presented in this report are based upon the data obtained from the Church and Associates, Inc. geologic exploration report dated November 27, 2002 and from any other information discussed in this report. This report • does not reflect any variations which may occur between borings or across the site. The nature and extent of such variations may not become evident until construction. If variations appear evident, it will be necessary to re-evaluate the recommendations of this report. It is recommended that the geotechnical engineer be retained to review the plans and specifications so comments can be made regarding the interpretation and implementation of our geotechnical recommendations in the design and specifications. It is further recommended that the geotechnical engineer be retained for testing and observations during construction phases to help determine that the design requirements are fulfilled. This report has been prepared for the exclusive use of Team Engineering for specific application to the project discussed and has been prepared in accordance with generally accepted geotechnical engineering practices. No warranty, express or implied, is made. In the event that any changes in the nature, design or location of the project as outlined in this report are planned, the conclusions and recommendations contained in this report shall not be considered valid unless the changes are reviewed and the conclusions of this • report are modified or verified in writing by the geotechnical engineer. Earth Engineering Consultants,Inc. • EEC Project No. 1072030 March 5,2007 Page 4 We appreciate the opportunity to be of service to you on this project. If you have any other questions concerning this report, or if we can be of further service to you in any other way, please do not hesitate to contact us. Very truly yours, Earth Engineering Consultants, Inc. Reviewed by: • 1 aN Ce(144.. % tt • Brian Stribley, E.I.T. Lester L. Litton, P.E. Project Engineer Principal Engineer • Feb 27 07 02: 46p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 4 � s CHURCH & Associates Inc. • ENGINEERS&GEOLOGISTS November 27, 2002 Weld 45-Acre, LLC,Ann: Lee Petrides c/o Team Engineering, Attn: Jeff Couch 3468 Shallow Pond Road Fort Collins, Colorado 80528 Subject: Preliminary Percolation Test Report, Proposed Moorea Manor North W %1 of Section 2, Township 2 North, Range 67 West of the 6th P.M. Weld County, Colorado Job No. I5226-L Mr. Petrides, As requested, we have conducted preliminary percolation tests as required by the Weld County Planning Department. The information provided in our report was based on test hole observations by our office on November 7, 2002 and percolation tests conducted on November 8, 2002. Percolation • tests are to be conducted on at least 20% of the total number of the lots proposed to comply with Weld County Planning Department's requirements for developing lots between 1 acres and 5 acres. PROPOSED DEVELOPMENT The proposed 45±-acre parcel is to be divided into 8 rural-residential lots, ranging in size from approximately 4.4 acres to 7.4 acres, as presented on Figure I. Part of-the roadway is shared- with Moorea Manor to the south and part is to be constructed on site. Domestic water is to be supplied by a public water system. Sewer services are to be constructed on site for each individual residence. SITE CONDITIONS The site is located southwest of Platteville, north of County Road 24% on the west side of County Road 21%a. The subject site consists of agricultural ground covered with weeds and grasses. Slope conditions vary from 0% to 5% generally to the east. Oil and/or natural gas wells were observed on and adjacent to the property. The Lupton Bottom Ditch is located near the west central portion of the site. SUBSURFACE CONDITIONS Three exploratory borings were drilled at selected areas of the site. Two percolation holes were excavated near Test Holes 1 and 3, each. Surficial soils at the site consist of 9 feet to 25 feet, or more, of silty and clayey sand. Sandy clay and claystone with sandstone underlie the sand in Test Hole 3;as presented on Figure 2. Percolation test results indicate percolation rates ranging from 27 minutes per inch (MPI) to 80 MN with one of the 4 percolation tests with a rate slower than 60 MPI. Free • groundwater was encountered in the test holes at depths ranging from 7.3 feet to 19.5 feet. DENVER 4501 Wadsworth Boulevard Wheat Ridge,CO 80033 303.463.9317 Fax:303.463.9321 Feb 27 07 02: 46p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 5 Preliminary Percolation Report Job No. 15226-L Page 2 • OWS FEASIBILITY The subsurface conditions and percolation tests indicates "standard" OWS may be suitable for most of all of the lots. Drain fields for these conditions may consist of trenches or beds. Trenches are preferred over beds as they can provide better treatment of wastewater and provide more sidewall absorption area than beds. One percolation hole indicated a percolation rate of 80 MPI. Engineered OWS will be required where average percolation rates are slower than 60 MPI. A low-pressure drip irrigation system (LPDIS) is a cost effective OWS for soil with slow percolation rates. All drain fields will need to meet required setbacks from the Lupton Bottom Ditch and other features delineated by County regulations. Shallow ground water levels, which may necessitate mounding of drain fields, may be encountered near the ditch. Costs of constructing "standard" OWS can range from $3500 to $5000 and will vary with the number of bedrooms constructed in the home, site conditions and contractor fee variations. Costs for constructing LPDIS can range from $5000 to $12,000.Mounding may add 10% to 50%to these costs. CONCLUSION Based on the data presented in this report, "standard" OWS appear to be the most appropriate system for providing wastewater service at this property. However, engineered systems may be required on the west lots or near the Lupton Bottom Ditch. The county requires site-specific percolation investigations prior to issuance of building permits. A site plan showing all existing and future buildings, driveways, corrals and other features to scale should be provided to the Engineer for OWS site determination and percolation testing. • If there are questions or we can be of further service,please call the Loveland office. Sincerely, :o:.t:^^^ °` p0 REGi CHURCH &Associates, Irry` P,..•• ••.., S cQ P` '04( 1< Barbara L. Dallemand, P)3 °' W BLD/twf 3 copies sent • • • are PROPOSED MOOREA MANOR NORTH • SCALE PART OF THEW 1/2 SECTION 2, 1" = 300' o T. 2 N., R. 67 W. OF THE 6TH P.M. • o WELD COUNTY,COLORADO ".' .a m 'LOT 6 TH 3 LOT 5 LOT 4 LOT 3 LOT 2 LOT I . cn TH 2 U, h, z m -} N m • 1 2% 704% I I 0% 703% I I I THI Ioa A SLOPE } SLOPE • . I •I I • I C • >- i LOT ? Os Z v c o n N oI LOT 8 — — -110 — r !\ r mI, . / a ' . . _ L 0 __AT_ _ _ __ , o • to co co TH I • - TEST HOLE (2 PERCOLATION HOLES LOCATED NEAR TH-I AND 1+3 EACH) 0 S - OIL/GAS WELL , 0 • 45. • THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN HEREIN; AND THE WELL AND/OR DRAIN FIELD LOCATIONS STAKED AT THE SITE; ARE NOT THE RESULT OF A PROPERTY SURVEY. IMPROVEMENT LOCATIONS ARE APPROXIMATE. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO DEFINE PROPERTY BOUNDARIES AND ENSURE ALL ONSITE IMPROVEMENTS ARE LOCATED WITHIN THE PLATTED SITE AND OUT OF INAPPROPRIATE EASEMENTS. ALL SEPARATION DISTANCES ARE TO BE VERIFIED PRIOR TO EXCAVATION. " • LOCATION OF EXPLORATORY BORINGS -o JOB NO. 15226-L AND PERCOLATION HOLES FIGURE 1 Q, Feb 27 07 02: 46p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 7 TH-1 TH-2 TH-3 D _ 0 • • - '•,.1 42/12 j 14/12 . 1 24/12 _ 5 WC =5.5 WC = 19.7 • WC=3.2 5 DD = 117 DD =111 - - 1 • -200=21 - - • — PI = NP —10 •; 1 33/12 ] 33/12 . 1 31/12 WC= 10.9 WC =15.0 WC = 12.3 10- - DD= 117 • - w w-15a. o • 1 15 O - 1 ;j 43/12 •-. 144/12 _' 50/7 - 20 WC = 17.9 WC= 16.3 20— DO =117 - • • —25 25 EXPLANATIONS: TOPSOIL 7- WEATHERED CLAYSTONE WITH SANDSTONE, MOIST, FIRM, GREY AND _G YELLOW SAND,SILTY TO CLAYEY,SLIGHTLY MOIST TO MOIST, MEDIUM DENSE TO DENSE, CLAYSTONE WITH SANDSTONE, MOIST; • BROWN TO UGHT BROWN HARD,GREY AND YELLOW 1 INDICATES DEPTH TO FREE WATER AND THE NUMBER OF DAYS AFTER DRILUNG THE MEASUREMENT WAS TAKEN . ll6/12 INDICATES THAT 6 BLOWS OF A 140 POUND HAMMER FALLING 30 INCHES WERE REQUIRED TO DRIVE A 2.5 INCH O.D.SAMPLER 12 INCHES. NOTES: 1. THE EXPLORATORY BORINGS WERE DRILLED ON 11-7-02 USING A 4-INCH DIAMETER CONTINUOUS FLIGHT AUGER POWERED BYA OSTRICH D-50 DRILUNG RIG. 2. WC = WATER CONTENT(%) DD= DRY DENSITY(PCF) -200= PERCENT OF FINES PASSING THE NUMBER 200 SIEVE. • JOB NO. 15226-L LOG OF EXPLORATORY BORING FIGURE 2 Feb 27 07 02: 47p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 8 PERCOLATION TEST RESULTS • PROPERTY OWNER: WELD 45-ACRE LLC PROPERTY ADDRESS: MOOREA MANOR NORTH LEGAL DESCRIPTION: PART OF W 1/2 SECTION 2, T.2 N., R. 67 W. OF THE 6TH PM COUNTY: WELD SIZE OF PROPERTY: 45± ACRES DIAMETER OF HOLES: 6 INCHES DATE HOLES EXCAVATED: 11-7-02 SOIL SURFACE SCRAPED: YES DATE/TIME OF PRESOAK: 11-7-02, 10:00 A.M. AMOUNT OF PRESOAK: 2-3 GAL/HOLE DATE/TIME OF PERC TEST: 11-8-02, 9:20 A.M. DEPTH DEPTH PERC PERC DEPTH MINUTES START END CHANGE RATE HOLE (INCHES) (INCHES) (INCHES) (INCHES) (MPI) I-A 32 30 22.50 25.25 2.75 30 25.25 26.38 1.13 30 26.38 27.25 0.88 30 24.13 25.13 1.00 30 25.13 26.13 1.00 30 26.13 27.00 0.88 34 I-B 33 30 22.75 25.63 2.88 30 25.63 27.13 1.50 30 27.13 28.25 1.13 • 30 24.75 25.88 1.13 30 25.88 27.00 1.13 30 27.00 28.13 1.13 27 3-A 29 30 19.50 20.38 0.88 30 20.38 20.75 0.38 30 20.75 21.25 0.50 30 21.25 21.63 0.38 30 21.63 22.00 0.38 30 22.00 22.38 0.38 80 3-B 27 30 16.25 17.50 1.25 30 17.50 18.50 1.00 30 18.50 19.25 0.75 30 19.25 20.00 0.75 30 20.00 20.75 0.75 30 21.75 22.50 0.75 40 O JOB NO. 15226- . TABLET Feb 27 07 02: 47p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 9 CHURCH & Associates, Inc. • ENGINEERS&GEOLOGISTS ENGINEERING GEOLOGY REPORT FOR PROPOSED MOOREA MANOR NORTH PART OF THE W 1/2 OF SECTION 2, TOWNSHIP 2 NORTH,RANGE 67 WEST OF THE 6 P.M. WELD COUNTY,COLORADO • Prepared for: WELD 45-ACRE,LLC ATTN:LEE PETRIDES CIO TEAM ENGINEERING,ATTN:JEFF COUCH 3468 SHALLOW POND ROAD FORT COLLINS,COLORADO 80528 JOB NO. 15226-L NOVEMBER 26,2002 • DENVER 4501 Wadsworth Boulevard Wheat Ridge,CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax:303.463.9321 EVERGREEN 303.816.1455 LOVELAND 970.663.2124 Feb 27 07 02: 47p SCHREFER FINANCIAL MGMT 303 770-1041 p. 10 TABLE OF CONTENTS SCOPE 1 PROPOSED DEVELOPMENT 1 SITE CONDITIONS 1 INVESTIGATION 1 SUE E GEOLOGY 2 MINERAL RESOURCES 3 GEOLOGIC HAZARDS 4 GEOLOGIC IMPACTS ON DEVELOPMENT • 4 LIMITATIONS 5 LIST OF REFERENCES 6 FIGURE 1 - VICINITY MAP FIGURE 2- SITE GEOLOGY AND LOCATION OF EXPLORATORY BORINGS FIGURE 3- AREA GEOLOGY FIGURE 4- MAP OF SAND,GRAVEL AND QUARRY AGGREGATE RESOURCES FIGURE 5- SOIL SURVEY MAP FIGURE 6- LOGS OF EXPLORATORY BORINGS FIGURE 7 THROUGH 9- SWELL-CONSOLIDATION TEST RESULTS FIGURE 10- GRADATION TEST RESULTS • Feb 27 07 02: 48p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 11 • SCOPE As requested, we have conducted this engineering geology report for the proposed Moorea Manor North, a proposed subdivision to be located in Weld County, Colorado. The purpose of our investigation was to identify site conditions regarding area suitability for the proposed development as requested by the Weld County Planning Department. PROPOSED DEVELOPMENT The 45±-acre parcel is located southwest of Platteville in the West Half of Section 2, T. 2 N., R. 67 W. of the 6`h P.M. It is proposed to divide the parcel into 8 rural-residential lots ranging in size from approximately 4.4 acres and 7.4 acres, as presented on Figure 2. Domestic water is to be supplied by public water. Sewer services are to be constructed on-site for each individual residence. • • SITE CONDITIONS • The site is located approximately 3%z miles southwest of Platteville, north of County Road 24%on the west side of County Road 21%. The Lupton Bottom Ditch bisects the west portion of the property. The property consists of agricultural land which appears to slope from 0%to 4% generally to the east, without the benefit of a topographic map. Drainage to the east of the site appears to be impeded by County Road 211/2. Vegetation consisted of grasses and weeds.. INVESTIGATION • This investigation was conducted by means of a site reconnaissance, test hole observations and percolation tests condtieled on November 7 and 8, 2002 by the author of this report, a Professional Geologist as defined under House Bill 1574. Readily available maps and literature by the Colorado Geological Survey and US Geological Survey were also reviewed for this preliminary • evaluation.Refer to the attached List of References. Feb 27 07 02: 48p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 12 • Engineering Geology Report Job No. 15226.-L Page 2 SITE GEOLOGY The area lies in the Colorado Piedmont Section of the Great Plains Physiographic Province. The Colorado Piedmont is an elongated trough situated adjacent to the Front Range. As mountain uplifting occurred in Laramide times, increased stream energies at the foot of the mountains resulting in erosion and scouring, creating the Piedmont. The site also lies in the Denver Basin, a thick accumulation of Mesozoic sediments,which have been producers of fossil fuels. Surficial soils at the site consist of silty and clayey sand, which were encountered in the upper 9 feet to 25+ feet in the test holes, as presented on Figure 6. Sandy clay was encountered from 9 feet to 13 feet in Test Hole 3. The sand is medium dense to dense and the clay was very stiff both having moderate strength characteristics. Samples of the sand exhibited no swell potential when wetted. Claystone with sandstone was encountered below the surficial soils in Test Hole 3. The upper 5 to 6 feet was slightly to moderately weathered. The unweathered claystone exhibits a high bearing • capacity. A sample of the claystone exhibited a low to moderate swell potential when wetted The Soil Conservation Service (SCS) maps indicate 3 general soil groups; the Loup-Boel loamy sand, the Valent sand and the Vona loamy sand, as presented on Figure 5. The soils were deposited as alluvium, eolium and a combination of alluvium and eolium, which is generally consistent with the geologic map, as presented on Figure 3. The SCS maps indicate low erosion potential in all of these groups. The SCS tables suggest severe limitations for building site development due to wetness and cave of cut-banks in the Loup-Boel loamy sand located along the Lupton Bottom Ditch_ This is,generally consistent with the groundwater level encountered in Test Hole 2. The SCS tables suggest severe limitations for building site development due to cave of cut- banks in the Valent sand. The SCS tables suggest severe limitations for septic systems in the Loup- Boel due to wetness. Three of our 4 percolation tests indicate percolation rates acceptable for • "standard"-type onsite wastewater systems(OWS)at the sites tested. Feb 27 07 02: 48p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 13 Engineering Geology Report Job No. 152264. Page 3 • The referenced geologic map indicates eolium and alluvium underlie the property, as presented on Figure 3. The eolium is described as wind-blown clay, silt and sand. The Broadway Alluvium is described as sand and gravel deposits by the South Platte River. Bedrock encountered in the borings consisted of the Laramie Formation(KI). The KI is described as gray claystone and sandy shale. The KI extends to several hundred feet in this location. No outcrops of the Laramie Formation were observed on the property. A swell"test indicates the underlying bedrock exhibits a low to moderate swell potential. There were no faults, folds or other structural features observed in the field or delineated on the referenced maps in this area Free groundwater was encountered in all test holes at depths ranging from 7.3 feet to 19.5 feet Ground water levels are ..apected to fluctuate with irrigation and ditch usage. Groundwater • levels are expected to be the shallowest along the Lupton Bottom Ditch. • MINERAL RESOURCES Colorado Geological Survey(CGS) Special Publication 5-B and the referenced geologic map and the test hole data from this report were reviewed as the primary references for the preliminary evaluation of sand, gravel and quarry aggregate resources and field verified by the geologist The geologic map and CGS publication indicate that the east 2/3rds of the parcel lies in terrace deposits with probable aggregate resources as presented on Figures 4. Our test holes did not encounter aggregate that would be considered economically viable. Due to the lack of aggregate resources, it is our opinion that this property is not economicalbor commercial extraction of sand, gravel or quarry aggregate. Oil/gas wells are ld ted on and adjacent properties. GEOLOGIC HAZARDS Maps indicating geologic hazards were readily available for the property. Our site • reconnaissance did not indicate any features which would suggest this area is located in a geologic Feb 27 07 02: 48p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 14 • • Engineering Geology Report • Job No. 15226-1, Page 4 • hazard area. No slopes greater than 10%were observed on the property. Based on this information,it is our opinion that there are no geologic hazards caused by gravity on the property. Excavations made in the sand may, may create conditions,which could result in unstable slopes and caving cut-banks. Drainage appears to be directed eastward towards County Road 211/2, where the road embankment is high_ The potential for flooding on low-lying lots should be considered. GEOLOGIC IMPACTS ON DEVELOPMENT The interaction of the proposed development and the geology of the site will depend on the types of structures proposed and specific geologic influences. The primary structures to be built are building foundations, roadways and.onsite wastewater systems(OWS). FOUNDATIONS. The upper sand exhibits moderate bearing characteristics and no swell potential when wetted, which are considered relatively stable soils. Spread footing foundations are anticipated • where sand underlies the foundations. The claystone exhibited a low to moderate swell potential. Where claystone and clay are encountered, as in Test Hole 3, drilled pier foundations and alternative floor systems may be required. Shallow groundwater levels are expected near and east of the Lupton Bottom Ditch. Construction depths may be limited in those areas. Site-specific geotechnical investigations are recommended for each structure to determine site-specific soil strengths, swell potentials and groundwater levels. Flood potential and drainage for low-lying lots should also be considered when planning construction. ROADWAYS-. In the event that the roadways are to be paved, a geotechnical investigation is recommended so that the pavement structure can be designed for the appropriate soil and traffic conditions. The sand generally provides good soil support for pavement structures, however, shallow ground water depths near the irrigation ditch may reduce soil support characteristics, requiring • additional stabilization. Feb 27 O7 O2: 49p SCHAEFER FIMRMCIRL MGMT 303 770-1041 p. 15 Engineering Geology Report • Job 14o. 15226-L Page 5 • ONSITF. WASTEWATER SYSTEMS (OWS)' Our percolation tests, presented in a separate report, indicate generally good percolation rates in the soil for placement of septic systems.Percolation rates in one of the 4 percolation holes was slow and indicating an engineered system may be required in that area A low-pressure drip irrigation system is a cost effective OWS for slow percolating soil conditions. Mounding may be required in low areas. Site-specific percolation investigations for OWS are required by the County Health Department prior to issuance of a building permit. GROT,OCTIC HAZARDS. The site observations did not indicate signs of geologic hazards caused by gravity, such as landslides, debris flows, rock fall, or unstable or potentially unstable slopes. Man- made activities could produce conditions, which may result in hazardous conditions, if not carefully planned No geologic hazard mitigation is anticipated for this site. Refer to OSHA standards for the appropriate protection methods. • • LIMITATIONS This study was preliminary in nature and did not include an extensive exploration program for the presence of oil, natural gas, uranium or other mineral resources. Based on readily available maps, literature and field data. Potential sand;gravel and quarry aggregate resources are not believed to.. exist in economic quantities. Although no geologic or soil hazards appear to exist in the present condition, site-specific geotechnical and onsite wastewater investigations should be conducted for each lot If we can be of further service in discussing the contents of this report, or to conduct site- specific investigations,pleasL'C81L CHURCH&Associates,Inc. ...•••••••u'u„ � �`E0F PAOFESS�04yA /7 C� e lrt�f\CATFyifejj%ea Thom Thomas W. Finley .G. "�� �°10516 ':toy: III 444 - I i ' , twf,3 copies sent f •'''' :: C5L isi:terge E`w`,A::94 Feb 27 07 02: 49p SCHREFER FINANCIRL MGMT 303 770-1041 p. 16 • LIST OF REFERENCES Colton,Roger B., 1978,Geologic Map of the Boulder-Fort Collins-Greeley Area, Colorado: U.S. Geological Survey Map I-855-G Johnson,Erin 1,and Himmeireich, John W. Jr., 1998,Geologic Hazards Avoidance or Mitigation: Colorado Geological Survey Information Series 47 Rogers,W.P.,Ladwig,L.R,Hombaker,A.L., Schowchow,S.D.,Hart,S.S., Shelton,D.C., Scroggs, D.L., and Soule, J.M., 1979, Guidelines and Criteria for Identification of Land-Use Controls of Geologic Hazard and Mineral Resource Areas, Colorado Geological Survey Special Publication 6 Schowchow, S.D,Shroba,RR, and Wicldein, P.C., 1974,Atlas of Sand,Gravel,and Quarry Aggregate Resources Colorado Front Range Counties: Colorado Geological Survey Special Publication 5-B • Tweto, Ogden, 1979, Geologic Map of Colorado: U.S. Geological Survey , 1980, Soil Survey of Weld County (Northern part, Southern part), Colorado: U.S. Department of Agriculture Soil Conservation Service • • Feb 27 07 02: 49p SCHREFER FINANCIAL MGMT 303 770-1041 p. 17 PROPOSED MOOREA MANOR NORTH SCALE • 1 . 50,000 PART OF THE W 12 SECTION 2, T. 2 N., R. 67 W. OF THE 6TH P.M. i WELD COUNTY, COLORADO N I !�1 t• • � i\'~� � N�• �I1pt�'4 Moore - • {a N, n. i • x-31 r.' 33"') �t Q µ.� _- 4DTTOM 1`>.I ` t. \ G� i^ h I Jj'j vI ( V��•9°° : T. 2 N. SITEc� _I /r_ a -7 \t COUNTY ROAD 24 1/2 -\ I V` ♦ \ .t. \� .- ,1_----..' • - n _ Si \ : \ `o.7, RIDGE JI. \. . -.'.4,9 Via"_. �p ._-.• .. virn •'1 ' .3'-={a_ % a� �I . ''�.S ice=- , -.. 7rI•CT . Ctd .• .I 99UH y jr.l l U I' S Grotel R. 67 W. I R. 66 W. lu- • VICINITY MAP JOB NO. 15226-L FIGURE 1 • • • U. N PROPOSED MOOREA MANOR NORTH SCALE 1" = 300' � PART OF THEW 1/2 SECTION 2, . T. 2 N., R. 67 W. OF THE 6TH P.M. ro WELD COUNTY,COLORADO n i 0 t .- 1JLOTÔ TH3 LOT5 LOT LOT3 LOT2 LOTI N TH 2 I I I OE I, • dr M 2O 4% I I TO I TM I N A % % SLOPE I SLOPE I I I a -n Ci (L017 � . 2 a QB I o I • LOT — _ — x Li ........— —ID — ----4. QE I l -i 9 _ � I — — . 47 a . 4) J TH I . - TEST HOLE o QE - QUATERNARY EOLIUM, WIND-BLOWN CLAY, SILT, SAND AND GRANULES 08 - BROADWAY ALLUVIUM - SAND & GRAVEL DEPOSITS BY THE SOUTH PLATTE RIVER 9 - OIL/GAS WELL p OPP - POST-PINEY CREEK ALLUVIUM - DARK GREY HUMIC, SANDY TO GRAVELLY ALLUVIUM .- THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN HEREIN;AND THE WELL AND/OR DRAIN FIELD LOCATIONS STAKED AT THE SITE; ARE NOT THE RESULT OF A PROPERTY SURVEY. IMPROVEMENT LOCATIONS ARE APPROXIMATE. IT IS • THE PROPERTY OWNER'S RESPONSIBILITY TO DEFINE PROPERTY BOUNDARIES AND ENSURE ALL ONSITE IMPROVEMENTS ARE • LOCATED WITHIN THE PLATTED SITE AND OUT OF INAPPROPRIATE EASEMENTS. ALL SEPARATION DISTANCES ARE TO BE VERIFIED PRIOR TO EXCAVATION. SITE GEOLOGY AND LOCATION OF -o JOB NO. 15226-L • EXLORATORY BORINGS FIGURE 2 m Feb 27 07 02: 50p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 19 PROPOSED MOOREA MANOR NORTH SCALE • PART OF THEW 1/2 SECTION 2, 1 ; 50,000 T. 2 N., R. 67 W. OF THE 6TH P.M. III WELD COUNTY, COLORADO N LH: • `--) • :-Qe r 1! BY•. _, SITE G'-.- •.e JI u Nv I . ° I VI `1 9 0 em I' . (1 /� ° QE - QUATERNARY E0LILM, WIND-BLOWN CLAY, SILT, SAND AND GRANULES QB - BROADWAY ALLUVIUM - ,S`AND a GRAVEL DEPOSITS BY THE SOUTH PLATTE RIVER QPP - POST-PINEY CREEK ALLUVIUM - DARK GREY HUMIC, SANDY TO GRAVELLY ALLUVIUM BASED ON USGS MAP 1-855-6 • AREA GEOLOGY JOB NO. 15226-L FIGURE 3 Feb 27 07 02: 50p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 20 PROPOSED MOOREA MANOR NORTH SCALE • PART OF THE W 1/2 SECTION 2, 1:37,500 T. 2 N., R. 67 W. OF THE 6TH P.M. WELD COUNTY, COLORADO N I ' - -N 7a }• ` A , f / `, � T3 sioT4 S 1 J • h'Thirili � ; • _ r ;I .�/� SITE: • fr a • • • k t O U4 /if 1. �. i11► • io 7 hs F 4 :: i4- L. . , t z IN L. F-FLOOOP(AIN DEPOSITS T-TERRACE DEPosrrs 3 -SAND 4-PROBABLE AGGREGATE RESOURCE WEST I/3 OF SL ELECT SITE LOCATED IN NCR-RESOURCE AREA EAST 2/3 OF SMELT SITE LOCATEb IN 14 AREA BASED ON:ATLAS OF SAND, GRAVEL E. QUARRY RESOURCES -COLORADO FRONT RANGE COUNTIES COLORADO GEOLOGICAL SURVEY SPECIAL PUBLICATION 5-B (1974) MAP OF SAND, GRAVEL &QUARRY AGGREGEATE RESOURCES • JOB NO. 15226-L FIGURE 4 Feb 27 07 02: 50p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 21 PROPOSED MOOREA MANOR SCALE • PART OF THEW 1/2 SECTION 2, 1' = 2000 T. 2 N., R. 67 W. OF THE 6TH P.M. WELD COUNTY, COLORADO r . 13 34 r , s. 72 76 • s n ae 1.73set ,r.: 69 /`� SITE p3 h T N ci, 3 h g e a. M, s9 a �p �� £ • - �� u ti , Ik .4,-;-•• rte..." R R3 72 4. -. #73h � tti i 1 r j r i- 46 2 6a & 73 � '-cr { e . • 72 fi t I 72 s j .ice 'i. mrsia KEY 35 -LOUP$CE.LOAMY sac-0%TO 3%swim 69-VAta77 SAND-0%70 3%Sl.0PF5 72-Vats LOAMY SAND-0%TO,S,%SLOPES 73-VONA LOAMY SAND-3%TO 5%SLOPS SOIL SURVEY IS BASED ON USDA SOIL SURVEY OF WELD COUNTY, COLORADO SOIL SURVEY MAP • JOB NO. 15226-L FlGURE 5 Feb 27 07 02: 51p SCHREFER FINANCIAL MGMT 303 770-1041 p. 22 TH-1 TH-2 TH-3 - 0 0 • • • - -•:1 42/12 , ] 14/12 .1 1 24/12 -5 • WC= 5.5 WC = 19.7 WC= 3.2 5 DD = 117 - DD= 111 1 -200=21 • - - PI = NP -10 . 1 33/12 ] 33/12 ..1 31/12 WC = 10.9 WC = 15.0 WC= 12.3 1 - DD = 117 W_ w 0-15 ., 1 15 Q 1 -- 20 . • j 43/12 .•'. 1 44/12 � 50/7 WC= 17.9 _ WC= 16.3 20 - - DD= 117 25 • - 25 EXPLANATIONS: ® TOPSOIL % WEATHERED CLAYSTONE WITH j4 SANDSTONE, MOIST, FIRM, GREY AND YELLOW SAND,SILTY TO CLAYEY,SLIGHTLY MOIST TO MOIST,MEDIUM DENSE TO DENSE, CLAYSTONE WITH SANDSTONE.MOIST, ' ' BROWN TO UGHT BROWN ® HARD, GREY AND YELLOW 1 INDICATES Du-,_IH TO FREE WATER AND THE NUMBER OF DAYS AFTER DRIWNG THE - MEASUREMENT WAS TAKEN 1 6/12 INDICATES THAT 6 BLOWS OF A 140 POUND HAMMER FAWNG 30 INCHES WERE REQUIRED TO DRIVE A 2.5 INCH O.D. SAMPLER 12 INCHES NOTES: 1. THE EXPLORATORY BORINGS WERE DRILLED ON 11-7-02 USING A 4-INCH DIAMETER CONTINUOUS FUGHT AUGER POWERED BY A DEITRICH D-50 DRIWNG RIG. 2. WC = WATER CONTENT(%) DD = DRY DENSITY(PCF) . -200= PERCENT OF FINES PASSING THE NUMBER 200 SIEVE. JOB NO. 15226 L LOG OF EXPLORATORY BORING RGURE 6 Feb 27 07 02: 51p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 23 • 8 I I . 7 I 6 5 I o ° I g. 3 I.11 I 2 CONSOLIDATION UNDER CONSTANT PRESSURE DUE TO WETTING 1 c 0 I • :NS-2 O 3 co I a I O I I I I i _5 -6 I I I I . -8 0.1 1 10 100 APPLIED PRESSURE -ksf Sample of Silty Sand from TH 1 @ 4' Natural Dry Unit Weight = 117 PCF • Natural Moisture Content= 5.5 % JOB NO. 15226-L SWELL-CONSOLIDATION TEST RESULTS FIGURE 7 Feb 27 07 02: 52p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 24 • S 1 1 i I III I II II 7 I 6 - I 5 O 4 'y a 3 , X W 2 I II III I NO MOVEMENT UNDER CONSTANT • 1 PRESSURE DUE TO WETTING c0 I 1 I III I I • -1 I I i i ii fn _3 co o i P • 0 v 5 I Ill I -7 i I 0.1 1 10 100 APPLIED PRESSURE-ksf Sample of Clayey Sand from TH 2 @ 9' Natural Dry Unit Weight= 118 PCF • Natural Moisture Content= 15.0 cro JOB NO. 15226-L SWELL-CONSOLIDATION TEST RESULTS FIGURE 8 Feb 27 07 02: 52p SCHAEFER FINANCIAL MGMT 303 770-1041 p. 25 41 8 " 11 HI I . 7 5 0 4 k3 1 j nil I W EXPANSION UNDER CONSTANT 2 PRESSURE DUE TO WETTING o p 4111 1 I I \' 2 3 I I I I I ti y U -5 I Ii I I I -6 I -7 _ ' ' 0 0.1 1 w 100 APPLIED PRESSURE-ksf . Sample of Claystone from TH 3 @ 19' Natural Dry Unit Weight = 117 PCF • Natural Moisture Content= 16.3 % JOB NO. 15226-L SWELL-CONSOLIDATION TEST RESULTS FIGURE 9 Feb 27 07 02: 53p SCHAEFER FINANCIRL MGMT 303 770-1041 p. 26 • CHURCH & Associates, Inc. Engineers & Geologists Dana,Colorado 303-463-9317 Evergreen,Colorado 303-816-1455 Cutic Rock,Colorado 303-660-4358 Lowland,C°kaado 970-663.2124 Gradation Test Results 0200 #100 050 #30 #16 48 #4 3/V 3/4' I-12' 3' • 100.0 ♦ 0 1 .1 900 - - • 10 80.0 20 70.0 i ' ' 30 • e e e 60.0 ` 40 E w e °i 50.0 - 50- Y X 40.0 0 40 30.0 . . 20.0 - I . I 80 10.0 90 I• I 1000.0 0.01 0.1 I 10 100 Diameter of Particle I,Millimeter DESCRIPTION: SAND,SILTY,SLIGHTLY MOIST,DENSE, LIGHT BROWN GRAVEL 0% HOLE/SAMPLE TH 3 SAND 79% DEPTH 4' . FINES 21% LIQUID LIMIT NP MOISTURE 3.2% PLASTICITY INDEX NP DRY DENSITY(pcf) 111 DATE: 11/25/2002 JOB NAME: WELD 45-ACRE JOB NUMBER: 15226-L FIGURE 10 • Hello