HomeMy WebLinkAbout20072715.tiff • 11. Evidence of Adequate Water Supply
The water from the well that was drilled under the Well Permit 115364 will be
used for the restroom facilities and for the intermittent cleaning of the
equipment at the station. Potable water will be supplied in bottles.
•
Frederick Compressor Station 11-1
TIN-R67W-15: NW1/4
Weld County, Colorado 2007-2715
WRJ•5•Rev. 76 CIRADO DIVISION OF WATER RESOUIS
• • 818 Centennial Bldg., 1313 Sherman St., Denver,Colorado 80203
PERMIT APPLICATION FORM RECEIVED ri
• Application must
be complete where ( ) A PERMIT TO USE GROUND WATER r
applicable. Type or (X ) A PERMIT TO CONSTRUCT A WELL JUL 0 31980
print in BLACK FOR: ( ) A PERMIT TO INSTALL A PUMP 41fll
INK.No overstrikes SIME py O1
or erasures unless ( ) REPLACEMENT FOR NO. COW
initialed. ( )OTHER
WATER COURT CASE NO.
(1) APPLICANT • mailing address FOR OFFICE USE ONLY: DO NOT WRITE IN THIS COLUMN/
NAME Panhandle Eastern Pipe Line Company Receipt No. IS, / /
STREET 635 North Seventh Avenue Basin Dist.
CITY Brighton Colorado 80601
(State) (Z•p) CONDITIONS OF APPROVAL
TELEPHONE NO. (303) 659-5922 This well shall be used in such a way as to cause
no material injury to existing water rights. The
(2) LOCATION OF PROPOSED WELL issuance of the permit does not assure the applicant
that no injury will occur to another vested water
right or preclude another owner of a vested water
County—�_ Weld right from seeking relief in a civil court action.
NW % of the 11W %,Section 15
Twp. 1 N, Rng. 67 W 6th P.M. APPROVED PURSUANT TO CBS 1973, 37-9L-602
'N.$) kE.WI (1) (C ) FOR DRINKING AND SANITARY
(3) WATER USE AND WELL DATA FACILITIES ONLY IN AN INDIVIDUAL
COMMERCIAL BUSINESS..
• Proposed maximum pumping rate(gpm) 1 5
THE AVERAGE DAILY APPROPRW'ION FROM THIS- WELL
Average annual amount of ground water1/2 SHALL NOT DCCFF.ED 800 GALLONS. /0,
to be appropriated (acre-feet): 11,
Number of acres to be irrigated: 1
Proposed total depth (feet): 550
Aquifer ground water is to be obtained from:
Owner's well designation
GROUND WATER TO BE USED FOR:
I ) HOUSEHOLD USE ONLY .no irrigation (0)
(X) DOMESTIC (1) ( I INDUSTRIAL (5)
( LIVESTOCK (2) ( I IRRIGATION (6)
( ir ""'�7-cvnn."rcrtcOIAL h11 dere ( ) MUNICIPAL (8)
X
I ) OTHER (9) .onA17 r 5:44)100)70A1,20€40,0:in avy APPLICATION APPROVED
DETAIL THE USE ON BACK IN (1 1) 115364
PERMIT NUMBER t(4) DRILLER DATE ISSUED .11,L 291980
Name Will take bids EXPIR / DATEJUL 29 1982
• Street
City lrflvnnn A •
e IN I
(State) (Zip) +���i
BY
Telephone No. Lic. No. _
I.D. / - 0L COUNTY 6Z
•(5) THE LOCATION OF THE PROPOSED WELL and the area on (6) THE MUST BE LOCATED BELOW
which the water will be used must be indicated on the diagram below. by distances from section lines.
Use the CENTER SECTION (1 section, 640 acres) for the well location. 420 North
• ft.from sec,line
+ — �-' -- �r. - �- — -� — -}- - -+ — + _ 4- (north or tsouth)
l L4-.---t MILE,5280 FEET---=fr1 I 165 ft.from West sec. line
last or west)
f + # •• + ± ± t
LOT BLOCK FILING •
I I I I
4 — —
I NORTH SE TION LINE _ + _ SUBDIVISION
(7) TRACT ON WHICH WELL WILL BE
l I LOCATED Owner: Panhandle Eastern
NORTH
+ z — — — — t"-i + ± No.of acres 48.56 Will this be
J -
I o m ' the only well on this tract? yes
-1- -i- 5 y 4- — -I-
w c (8) PROPOSED CASING PROGRAM
H I I z
I w r I Plain Casing
-I— 4— 3 — —1-- — — 4- - it: + - 6 5/3 in.from 0 ft.to 450 ft.
I I I I in.from ft.to ft.
- SOUTH SE TION LIN — -4- — _l_ Perforated casing
I I 4 1/2 in.from 450 ft.to 550 ft.
+ + -F- 4 t 4 -4- -4- in.from ft.to Y.
I I I I (9) FOR REPLACEMENT WELLS give distance
and direction from old well and plans for plugging
- -4_ - + - 4_ - -� - -F- -- -4- - - + it:
• The scale of the diagram is 2 inches= I mile N/A
Each small square represents 40 acres.
WATER EQUIVALENTS TABLE (Rounded Figures) •
An acre-foot covers 1 acre of land 1 foot deep
1 cubic foot per second lcfsl ...449 gallons per minute(gpm)
A family of 5 will require approximately 1 acre-foot of water per year.
1 acre-foot .. .43,560 cubic teat...325900 gallons.
1,000 gpm pumped continuously for one day produces 4.42 acre-feet.
(1O) LAND ON WHICH GROUND WATER WILL BE USEQ
Owner(s): Panhandle Eastern Pipe Line Company No.ofacres: 48.56
Legal description: SPP-FXHTR IT "A"
(11) DETAILED DESCRIPTION of the use of ground water: Household use and domestic wells must indicate type of disposal
system to be used. Drinking and sanitation purposes_ also provide water for approximately
400 trees which will be placed ilaide the property-boundary.,f,�F,fr' Tkr, w;///x Z tape e
ha Tr• Caresser Srsyb.- "se .tarre*/
(12) OTHER WATER RIGHTS used on this land, including wells. Give Registration and Water Court Case Numbers.
Type or right Used for(purpose) Description of land on which used
None N/A N/A
(13)THE APPLICANT(S) STATE(S) THAT THE INFORMATION SET FORTH HEREON IS
TRUE TO THE BEST OF HIS KNOWLEDGE.
• SIGNATURE OF APPLICANT(S)
Panhandle Eastern Pipe Line Company
R. E. Park
Right-of-Way Representative
• Use additional sheets of paper if more space is required.
• 12. Evidence of Adequate Sewage Disposal
The compressor station has a domestic water well for restroom facilities with septic permit#110-80.
•
•
Platteville Compressor Station 12-1
T3N-R66W-13: SE1/4
Weld County, Colorado
a
WELD COUNTY HEALTH DEPARTMEN! ?Don
1516 Hospital Road Permit No. /(,
r Greeley, Colorado
PH. 353-0540
•pplication for permit to install, construct, an Individual Sewage Disposal System.
Owner .t'41/f's1/ t' E 35 41i Address %,.,i, 405(21//„=-P-7 Phone
Directions to site: Hwy Rd. N mi, E mi, S mi, W mi
Legal Description: Ptn.j1C/// Sec. /5- ,T / N, R ,/,:(2,7W, Sub. Lot Blk
Information I De t. Use Onl
i1,�/%�1�11C S7 � If N No. Bedrooms ,/)y,;7[/ L3YIiCe 02!:b , Persons p( 7 Perc rate ( vg. of 3) ?0,164 No. Baths / Baseule j� 8'nt Plumbing AA9 , Soil Type
Size of Lot 4/K,4(4f4:',5 P,$ H2O Table Depth > 5 1su ak%.
H2O supply (If well give depth) L{/e7/ Lot Grade L?-O °jig
New Home Mobile Home Modular Add'n 4Ap(/ Engineer Design Yes )L No
Type of sewage disposal requested: 4)4ri)4 1_ (rigs If YES-reason:
Septic tank if Privy Other Comments:
This is to certify that the system is NOT within 400 ft. of a public sewer '� '
/,
J IInns�taallllation instructions: (Minimum Requirements)IIISeptic Tank / v U v Gals. Absorption Trenches O-5V —_"q. Ft.
Other or
�Special Instructions Seepage Bed � Sq. Ft.
This system will be constructed and installed in accordance with the above specifications
and regulations regarding individual sewage disposal systems in Weld County, Colorado.
This permit shall expire at the same time as the building permit, or, if no building permit
is issued, the permit shall expire 120 days after its issuance if construction has not
been commenced.*
Date: g/,lc- - Owner: !. /.. ✓,d
Applicant:
The plans and specifications as shown are approved pending payment of permit fee.
Date: fj— 49Cr rtn
Sanitarian:- -
The above system inspected nd found to comply with plan and description.
4 Systems Contractor: , 'l1 el__ Date: ` '�7I1I
Sanitarian: 14r7--/u/A„A_ LA
Engineer Review:
(Date) (Signature)
L.
S'ermit Fee: $ 27.‘
Received by: 714,;y' ' {':, _liL -. / e"Date/ Date:_ ir:! C.=---
19-79-122
Peres k eicAe,,siah ' �d • 13. 81 — ShGttm Gre�a ea,ha Rd1e ro i`ed
T
a•f3b/ Q -vn-a F,( ce theVI are sM II awa6-�-inc, or Ra. Ptca..* o t K rAil'a erejee� ar,d e' -iry
/ race oA c{ aPProvat ., 1 h'crcl, , kgi, I
• +1 ,
?pu,A
c,-Fz-amend--r„�
icy
o r
30
•
-3 6 b
•
Hello