Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Browse
Search
Address Info: 1150 O Street, P.O. Box 758, Greeley, CO 80632 | Phone:
(970) 400-4225
| Fax: (970) 336-7233 | Email:
egesick@weld.gov
| Official: Esther Gesick -
Clerk to the Board
Privacy Statement and Disclaimer
|
Accessibility and ADA Information
|
Social Media Commenting Policy
Home
My WebLink
About
20062323
=Pal l PIPE L:t IE CO IN,: r-• FA}' W. :;L' 659 8J.-4 Feb. 11 2005 10:5"AI.1 Forr.7 tic..- OFFICE OF THE STATE ENGINEER cWs-25 COLORADO DIVISION OF WATER RESOURCES 819 Centennial 6idg , 1312 Shearer, t..4ei,ier.Colorado 80203 (303)866-3581 f EXST WELL PERMIT NUMBER -_ _261608 • APpLiGANT DIV. 1 WD 2 DES. BASIN MD APPROVEQ WELL LOCAT ION WELD COUNTY NW 1/4 NW '1/4 Section 29 KENNETH T & MARGARET SHANNON Township 1 N Range 66 W Sixth P.M. P O BOX 843 QISTANGES FROM SECTION LINES BRIGHTON, CO 80601- 1300 Ft. from North Section Line 290 Ft from West Section Line (303)659-8850 UTM COORDINATE'S(NAD83) PERMIT TO t9SE AN EXISTING WELL Lasting. 516257 Northing. 4430645 ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CQNOITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit dnes not ensure that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action, 2) Construdion details for this existing well have not been provided to this office;therefore, it is not known if the construction of this well is in compliance with the Water Wel!Construction Rules, 2 CCR 402-2. The issuance of this permit does not Ef relieve the well owner of responsibility or liability in the event contamination of the groundwater source results from the construction or use of this well.nor does the State Engineer assume any responsibitlty or liability should contamination occur. 3) Approved pursuant to CRS 37-92-60?(3)(b)(I)and the policy of the State Engineer dated 419185 for appropnaticn of ground water tributary to the South Platte River system 4) Approved for the use of an existing well registered under well permit no. 570-R Permit no 570-R has been cancelled. 5) The use of ground water from this well is limited to drinking and sanitary facilities as described in CRS 37-92-802(1)(c), for a commercial business. Water from this web shaft not be used tor lawn or landscape irrigation or for any other purpose outside the business building structure b; Production from this well is restricted to the alluvial aquifer. 7) The pumping rate of this well shah not exceed 15 GPM. 8) The annual amount of ground water to be diverted by this well sh311 not exceed 1/3 acre-toot(108,800 gallons) 9) Approved as the only well on a tract of land of 5.95 acre(s)described as Lot B, Recorded Exemption no. 1471-2ty-2 RE3380.Weld County. rcf_ronce attaches!exhibit A . 10) The return flow from the use of this well must be through an individual waste water disposal system of the non-evaporative type where the water is returned to the same stream system in which the well is located. The maximurn consumptive use of ground water shall not exceed 10 percent. 11) A totalizing Row meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be maintained 0y the well owner(recorded at least annually)and submitted to the Division Engineer upon request. 12) This well sh3li be located not more than 200 feet from the location specified on this permit. 2.12.1a6 APPROVED e —-- Jfn1d1_. • • 441.104 1 Stale Engineer _ - Rece;�t No.0530057 - - DATE iSS . 0 -01-2005 . / /' �`� _� ._._ �?X�R4TlON D. 2006-2323 FCJM HAtlN'itI Pi PE LINE CO INC .•►. FH 659 985© Feb. 11 20305 10:5741 P.7 ORDER OF THE STATE ENGINEER IN THE MATTER OF WELL PERMIT NO 570-R RECEIPT NO, 9058515 LOCATION' - NW1/4, NW1/4, SECTION 29, TOWNSHIP 1 N, RANGE 66 W APPLICANT: - KENNETH T 8 MARGARET SHANNON THE STATE ENGINEER FINDS: The well permit was registered on September 1, 1959. On January 24. 2005, evidence was submitted that the well would no longer withdraw water under permit no. 570-R. The evidence submitted is as follows. The applicant submitted a well permit application to change the use of the existing well to commercial exempt. The well permit is hereby cancelled and is of no further force or effect. Dated this _Z'Cl. day of_ Qort.A.C..oN , 2005 Hal D Simpson State Engineer By ann Williams Water esource Engineer Prepared by: JMW cc: Division 1 Applicant /Form#0560(8) FROM : SHANNON PIPE LINE CO l Nf= Fax: NO. : 303 859 8850 Ju 1. 28 2005 it:35AM PI WELD COUNTY DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT 1555 NORTH 17TH AVENUE GREELEY, CO 80631 PHONE (970) 304-6415 FAX (970) 304-6411 Permit t: SP-0500144 Sec/Twn/Rng: 29-01-66 Status: ISSUED Owner: SHANNON KENNETH & MARGARET Applied: 04/29/2005 Applicant: SHANNON MARGARET Issued: 05/26/2005 Permit Type: CNEW C=Commercial,R-Residential+ NEW,REPair, VauLT Finaled: 7,:25-105 Parcel #: 1471-29-2-00-115 Location: 1760 WCR 27 Legal Description: Installer: Description: 1200 SQ FT STRUCTURAL STEEL WAREHOUSE Commercial: Y Residential:N Acres: 5 #of Persons: 15 Basement Plumbing: N #of Bedrooms: 0 Bathrooms- Full: 0 3/4: 0 1/2: 5 Water Public: N Water Source: Water Private: Y Cistern: N Well: Y Well Permit#: 261608 Percolation Rate: 20.8 Limiting Zone: 8 ft 0 in Description: %Ground Slope: 0 Dir: Soil Suitable: (Y/N) Y igineer Design Required: (Y/N) Y in 100 Year Flood Plain: (Y/N) N Minimum Installation Chambers* Septic Tank: 1000 gallons Absorption Trench: S75 square feet or Absorption Bed: 0 square feet Actual Installation Septic Tank: /x gallons Absorption Trench: square feet Absorption Bed: e y square feet �g Design Type: C.-, .k . Chamber Model NOTICE The issuance of this permit does not imply compliance with other state,county or local regulatory or building requirements,nor shall it act to certify that the subject system will operate in compliance with applicable state,county and local regulations adopted persuant to Article 10,Title 25,CRS as amended,except for the purpose of establishing final approval of installed system for issuance of a local occupancy permit persuant to CRS 1973 25-10-111 (2). This uermit is non trLinsferabie and non refundable. The Weld County Department of Public Health and Environment reserves the right to impose additional terms and conditions required to meet our regulations on a continuing basis. Final permit approval was contingent upon the final inspection of the completed system by the Weld County Department of Public Health and Environment. x5•O5 �. E iro ental Health Specialist Date S_FINAL FtJL-28-2005 THU 12:29Pf•M ID: F E: 1
Hello