Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Browse
Search
Address Info: 1150 O Street, P.O. Box 758, Greeley, CO 80632 | Phone:
(970) 400-4225
| Fax: (970) 336-7233 | Email:
egesick@weld.gov
| Official: Esther Gesick -
Clerk to the Board
Privacy Statement and Disclaimer
|
Accessibility and ADA Information
|
Social Media Commenting Policy
Home
My WebLink
About
20042653.tiff
MINUTES OF THE WELD COUNTY UTILITIES ADVISORY COMMITTEE A regular meeting of the Weld County Utilities Coordinating Advisory Committee was held on Thursday, August 12, 2004, at 10:00 a.m., in the Conference Room of the Weld County Planning Department at 918 10th Street, Greeley, Colorado. Members Present: Doug Melby, Brent Shafranek, Jed Reed, Don Somer. Also Present: Sheri Lockman, Voneen Macklin, Don Carroll, Michelle Martin. Don Carroll called the meeting to order. CASE NUMBER: PF-594 PLANNER: Sheri Lockman APPLICANT: Todd Muckier, Debra Eberl & Eli Krebs LEGAL DESCRIPTION: Lot A and B RE-2695; Pt W2 Section 29, T5N, R67W LOCATION: South of and adjacent to CR 54; approximately 1500 feet west of CR 15 /z. For a more precise location, see legal. REQUEST: A PUD Final Plan for seven (7)lots with (E) Estate Uses and four(4) non residential outlots Sheri Lockman presented case PF-594. The utilities are provided by Little Thompson Water, Xcel Energy, Poudre Valley REA and Qwest. Tom Hahn, applicant, provided clarification with regards to the history of the project. The property has gone through a couple of owners and in the mean time there was a home built on the property. The net result of the home being built was the utility location which defined the issues of easements was established. The gravel extraction continues on the north of the property. There may be some non family lots sold but the majority will belong to family. The gravel extraction area will become common area open space for the HOA. The parcel that contains the river will retain the pasture grass that is currently there. The required space has been provided to the Oil & Gas Company. The required space for this has been designed to be a part of the open space. Don Carroll asked about Outlot C& D and if it is part of the Lakota Lakes? Mr. Hahn indicated it will be either owned by the HOA or the original owners will retain the pasture. Mr. Carroll stated there was no chance of building on Outlot C because it is a gravel operation or lake. Mr. Hahn stated it is surface water but it is also within the flood plain so there will be no substantial building in the area. Mr. Hahn added it will not be residential. Mr. Carroll added that the reason for the question on the outlots is typically a parameter easement is requested. It will be up to the board to determine. Mr. Hahn stated that the owners are not in opposition of the easement if it is felt to be necessary. Sheri Lockman added that there can be nothing on Outlot C because of the amount of water. Outlot D and Outlot B can have an agricultural structure that may have lights. Mr. Hahn indicated that electric service can come from the road for Outlot B. Ms. Lockman added that if the board wanted a future easement up the road it can be extended. Mr. Hahn stated it would be fine to have utility easements on both east and west sides of the property. Mr. Carroll stated the outlots need accommodating in case there is ever structures. Ms. Lockman indicated the access road has been included in outlot C. Don Carroll asked about the 20' utility easement for Little Thompson, is this exclusive? Mr. Hahn indicated he was not sure whether it was exclusive or not. It was put in place to allow the water line for the home that was built. Mr. Carroll asked if there is a recording number that it be placed on the plat. Mr. Carroll indicated there was a sign off block for the utility companies and requested that this be done. Ms. Lockman indicated it will be done prior to recording. Sheri Lockman added that lot 1 has a drainage easement but no utility easement on the west side and lot 7 is missing frontage utility easements on the internal sides of the lots and along the access road there is no easements. Mr. Hahn clarified that on the western edge of lot 7 wrapping around the cul de sac going east along outlot C and south along outlot C needs the easement of 15'for utility/drainage. 2004-2653 Don Carroll stated that at the bottom of outlot C the right of way could be used to accommodate access to the lot. The river configuration to lot D for access will need to be different. Mr. Carroll suggests extension of a 15'parameter easement across the top of outlot C and across outlot D. Mr. Hahn added that anything south of the property, because of the river, will be accessed from the south so as not to cross the river. Mr. Hahn asked for clarification regarding the exclusive agreement with Little Thompson and should it not be a recorded easement there would be no need to obtain a book and page. Mr. Carroll indicated that if this is not recorded it will be fine but if recorded please reference. Don Somer moved to approve Case PF-594 along with the additions and corrections including revising the plat to reflect additional utility and drainage easements. Doug Melby seconded. Motion carried. Sheri Lockman summarized the requested modifications. They are as follows: 1. Lot 1 east side will be labeled 30'drainage and utility easement. 2. Lot 7 needs a 15' parameter easement around the cul de sac and on the east side along the access road. 3. 15'utility easement on the east side of outlot C to access outlot D and a recording number will be researched for the utility easement for Little Thompson Water District. If so it will be placed on the plat. The signature block for utilities will be completed prior to recording. 4. Extension of the 15'utility and drainage easement across the top of outlot C& D for future structures. CASE NUMBER: RS-1063 PLANNER: Michelle Katyryniuk APPLICANT: Beckles LLC, Martin, Gilchrist, Raben, Larson, Holman, Smith, McGurk, Weaver LEGAL DESCRIPTION: Lots 12-17 of the 1st Addition and Lots 11 & 18 of the 2nd Addition of Johnson Subdivision; Pt NE4 Section 2, T5N, R66W LOCATION: Adjacent to B Street and North of 42nd Ave. For a more precise location, see legal. REQUEST: Resubdivision for the Vacation of Road, Street or Alley Right of Way. The Resubdivision will vacate a portion of"B"Street Michelle Martin, Department of Planning Services presented Case RS-1063, reading the recommendation and comments into the record. The Department of Planning Services is recommending approval of the application. Additional information requested for utility sign off has been provided by the applicant. The utilities affected were the City of Greeley for water, Xcel, Comcast, Greeley Gas and Qwest. Don Carroll indicated that this case was reviewed at the July 8, 2004 hearing and the board requested the applicant get a sign off from the affected utilities. The applicant has provided a sign off on the plat for those utilities. Gene Brantner, applicant, provided history on the vacation of B Street. A portion of B Street to the west of 40th Avenue was vacated in 1996. The City of Greeley is doing a forced annexation and the property to the east will be developed into multi-family units. The City of Greeley Planning Commission has agreed to close the road to non-motorized vehicles but that does not mean they cannot open it at a future date. The applicant is trying to vacate B Street from 40'"Avenue east so this would help keep the road closed. Don Carroll added that as the Utility Board they cannot vacate but they can deal with the utility portion. The vacation would come through other boards. Michelle Martin added that she has received nothing from the utility companies to indicate a concern. Gene Brantner added that he was very thankful to Planning Department and Jerry Adams from Atmos Energy for the guidance received. Don Somer asked about the 20'water line exclusive easement by the City of Greeley and if any other utility can locate in the same easement. Mr. Brantner indicated that the water, gas and Qwest are the only utilities located in the street all others are located along the side or the rear of the lots. Don Somer moved to approve RS-1063. Doug Melby seconded. Motion carried. CASE NUMBER: PF-1011 PLANNER: Sheri Lockman APPLICANT: Doug Tiefel/River Runs Through It, LLC-Pelican Shores LEGAL DESCRIPTION: Part of the E2 of Section 36, T3N, R68W LOCATION: North of and adjacent to CR 26 and west of and adjacent to CR 13. For a more precise location, see legal. REQUEST: PUD Final Plan for 40 lots with R-1 (Low Density Residential)Zone Uses along with 193 acres of open space consisting of a river corridor and tow private recreational lakes Sheri Lockman presented case PF-1011. There are two distinct sides to the development, the north and the south. They should be viewed independently due to different service providers. Water is provided by Central Weld Water District on the south side and Little Thompson Water District on the north side. Other services providers are St. Vrain Sanitation District, Kinder-Morgan, United Power and Qwest. The south side will be reviewed first. Doug Tiefel, applicant, provided additional information regarding the easements on the project. The south portion will be developed first. There is a 54 acre lake and 26 lots that will all contain frontage in the back yard on the lake. The internal road will be private, paved with no curb and gutter. CR 26 will be paved with curb and gutter. The easements are in the front adjacent to the roads and in the roads. The easements on side and rear of the lots is not necessary due to all services being extended from the front. The rear of the lots will contain walk down structures to access the lake, for example boat docks, landscaping and such. Central Weld Water and St. Vrain will have the collection lines in the road. The 12' utility easement on each lot would be sufficient to place all the utilities in. Kinder Morgan is working to extend their line to the development and a proposal is being worked on. United Power will do the engineering for their distribution. Don Carroll asked about the 12'foot on the utility easement. Mr. Tiefel stated there was a calculation and this was the number determined to work. It was based on a 60'right of way and 12 foot easement adjacent. The number could be 15'. The anticipation was to put electric, cable and phone in the same trench. Gas would be in a separate trench while water and sewer are in the right of way. Mr. Carroll asked about the internal road. Mr. Tiefel stated it would be paved and possibly gated. The parameter laterals are protected with easements. Mr. Tiefel added the augmentation plan does not allow for the use of the water in the laterals. Tract A is the open space and there is an area that is designated as a non exclusive utility easement. Mr. Tiefel referenced a map of the area to describe the open space, tract a and the lake. The locations were identified. Mr. Somer asked for clarification with regards to the identification being confusing on where the utility easement is located on tract A, it does not affect the whole tract of land. Mr. Tiefel indicated it would be identified better. Mr. Somer requested identifying the non exclusive utility easement on tract A in all areas affected. Mr. Carroll asked about the 12'easement and it being front line. Ms. Lockman added it is usually 15'and there is typically a 20'foot in back when the 15'front cannot be met. A discussion ensued as to the minimum size of an easement that could be needed. Mr. Reed added that the coordination of the utilities is the key, if it can be done the 12'is a possibility. Mr. Tiefel added that he would be willing to place a conduit in the area if needed. Mr. Tiefel agrees to the 15'on the front. Mr. Somer stated that 15'foot easement in the front. Mr. Tiefel added that a note will need to be placed indicating the road can be used as a utility easement also. Doug Melby asked where the fire hydrants will be located. Mr. Tiefel stated they are on the edge of the asphalt at a common lot line and there are four of them. Mr. Tiefel added that sanitary sewer will be in the street. St. Vrain Sanitation District will be redoing their main located in CR 26 and this proposal gravity drains. The internal collection system will be under asphalt. Mr. Shafranek stated that St. Vrain is exclusive and they would like an exclusive easement called out and platted. Mr. Shafranek added they may need more room in the ditch on CR 26. Mr. Tiefel added there may not be enough room due to the irrigation lateral. The south side of the road will be used because the line can be paralleled. Don Carroll asked if all the utilities will be coming in on the main entrance so not cutting across any lot lines. Mr. Tiefel stated that was correct. Don Carroll asked for opinions on lot line easements and how everyone felt. Mr. Reed stated for ease of access and maintenance a larger front would be better than rear lot easement. Mr. Tiefel stated that the rear lot lines go down to the lake and all utilities are available from the front. Mr. Carroll stated that the typical is parameter easements. This proposal is requesting front easement access only. Mr. Carroll asked what the comfort level is for the front easement, 12'does not seem adequate. Mr. Reed asked if there is a possibility of 20'in the front. Mr. Tiefel stated that when it is greater then 15'the amount of space for trees on the frontage of the lots will be limited. The covenants are very tough and limited. The 15'would be acceptable. Mr. Reed added that it is more beneficial to obtain the easement at the beginning of the development therefor there is no need to return and ask for more. Mr. Somer asked about 10'on the back lot line? Mr. Tiefel does not believe that to be necessary, the rear lot line will be the lake. The easement could eventually be under water at times. Mr. Somer stated that if enough is not asked for at the beginning it is very tough to get later on in the process. Mr. Tiefel stated that all six services are provided from the front. Mr. Tiefel stated that the development will be placing the conduit in case the utilities are not ready to install at the time needed. Brent Shafranek stated that if they allow the 15'front easement the developer needs to put conduit in for the possible future use. Mr. Reed stated at least place the conduit for the needed utilities. Don Somer asked about the open space. Mr. Tiefel stated the covenants will state structures cannot be located anywhere they inhibit the use of the open space Mr. Somer still wants to see a back lot line easement. He would rather put more than needed and vacate what will not be used. Ms. Lockman indicated staff has"will serve" letters but does not have the official signatures until prior to recording. Mr. Somer added Qwest would do a front lot entrance. Doug Tiefel stated the grading on the rear lot line is very steep. Mr. Reed asked if they only have front easements will they have a pad for phone, cable and power. Mr. Tiefel stated the pads are located every other lot at the common lot line. There should be plenty of room with the open space, the right of way then the easement. The north side will be reviewed now. Don Somer asked about the 30'easement on the north side of the lots. Mr. Tiefel stated Little Thompson wanted exclusive easement with the other utilities placed further away. The lots are long and narrow with St. Vrain Sanitation on the bottom side. Mr. Tiefel stated Little Thompson wanted the easement wider so there would be no conflict. Brent Shafranek asked where the easement on the south side was. Ms. Lockman stated it was printed in lot two. Mr. Shafranek asked if St. Vrain would be the only one coming from the rear of the lot while all other utilities will come from the front. Mr. Tiefel stated that was correct. Mr. Shafranek asked about the overlapping easements? Mr. Tiefel stated it was a non exclusive emergency access easement. Doug Melby asked if there would be room on Lots 7& 8 to build with the setbacks. Mr. Tiefel stated they would, the design would need to be done around that. Don Carroll pointed out there is no parameter easement or back lot line easement but the 30' is provided and the 20'St Vrain Sanitation in the rear. Mr. Shafranek asked how much of the 30' Little Thompson will be using. Mr. Tiefel was not sure but the section diagram was reviewed and it was accurate. Mr. Carroll asked if the width Little Thompson needs should be noted on the plat? Mr. Tiefel stated they would use the north side of the trench and will be worked out with all applicable utilities. Sheri Lockman asked about the 30'that ends at the cul de sac? Mr. Shafranek stated it would need to be continued. Mr. Tiefel stated the issue is when Carma bought the adjacent property they were unwilling to finalize the previously agreed upon easements. Mr. Tiefel stated he has engineered everything they need for the homes they are developing and Carma can figure out what they need to do when their time comes. Mr. Reed added the value would be the connection being a convenience for future possibilities. Brent Shafranek added that St. Vrain would like to have stub outs available even if the situation with the neighbor is not amicable. Mr. Carroll added inner connectivity is important to Pubic Works. r Brent Shafranek moved to extend the 30'easement around the cul de sac and to the west to the property line. Jed Reed seconded. Motion carried. Don Carroll stated the big question is the back lot line around the parameter. Mr. Somer stated the back lot line easements are on the north side but not on the south. Why the need for the north but not the south. Mr. Tiefel stated the line was already constructed and at the bottom of the slope, it was granted four years ago. Mr. Somer indicated he would leave it up to the board but there are other developments that have back lot lines. Don Somer moved to have 10'easement on the back lot lines around the south lots. There was no second. Discussing the South Side: Brent Shafranek indicated the concern for the 15'on the front and if it is enough. Mr. Reed stated the installation is fine but maintenance is the question. The compromise would be the front be larger with no rear lot lines. Mr. Tiefel stated that they would come off the center line 5'; then 5'for gas, 5'for electric and phone, this would be the 15'. Mr. Carroll stated the 5'dimension needs to be reviewed, does this mean a 5' separation between trenches. Mr. Tiefel stated that was correct. Mr. Tiefel stated the sole reason for not wanting 20'was to get trees closer to the street. It is not a street tree when you are 40 -45'away from the street. Jed Reed added that 15'is tight but since there is usable land in the area it would be fine. • Jed Reed moved to have 15'in the front for easement. Doug Melby seconded. Motion carried with Don Somer voting no. Sheri Lockman summarized the recommended changes for PZ-1011 and they are as follows: 1. St. Vrain Sanitation must have an exclusive agreement on the south end across Lot A adjacent to Pelican Shores drive. 2. A note that the water and sewer easement is in the roadway. 3. 15'front lot line easements on the south side. 4. A note stating Tract A is a utility easement on the south and east of Pelican Shore Drive 5. A 30'utility easement on the north side around the cul de sac and west to the property line. Brent Shafranek moved to approve with the conditions suggested. Jed Reed seconded. Motion carried with Don Somer voting no. Re¢pecffully submitted, 7 Voneen Macklin Secretary LITPLE THOMPSON WATER DISTRICT , mimic mil,,;,.0=9 6324096 mnnwbd• 835E Ladd _September 12, 2000 ° a.. mmww w. MonhWeeson °VW&sx.pn". - JeS.W Ikek WitIMEM flood 1 r ! Mitt Forbes Forbes Park Ranch, LLC 229 S Priced Rd 36 Longmont, CO 80501 • Dear Mr. Forbes: This letter" is in response to your request for an updated water service commitment for up to 6 residential lots, in the proposed subdivision 'described as follows: PORTIONS OF SEC.29, T5N, R67W -- WELD COUNTY, CO The District provides water service within its service area as defined by the District. The provision of , water . service by extension of- existing water. lines of .the District to the above property and the installation of taps for lots is done under the terms of the Rules and Regulations of the District established by the Board of the. District. from time: to time. You may obtain a copy of the Rules and. Regulations fron the T District. This letter outlines the povisions of the Rules and Regulations, however this letter does-not change any provisions of the Rules and. Regulatuona". The Board of the District" may- alter and. amend the Rules - and Regulations at any time, and the provisions of this letter are subject to alteration and amendment based on changes in the Rules and Regulations of the District. We currently have a 12"_ Dia. water line located at the intersection of WCR 15 & WCR'.54 with additional capacity available Therefore, we can commit to provide service to the above property, subject to the; limitations in this letter, for pne standard residential . 5/8" X 3/4" water tap per lot; and the following additional limitations on the provision of water -service are: 3 ' • + • I'a S. ': 7 )" 1. In August of 1993 the Little Thompson Board implemented a _ "system +mnact" fee 'of` Sioso „er lot for alt lots' to be r f 1 added to the system. This is due upon completion of the main r+� I16,o°° (/line extension agreement. 2.. All improvements to District facilities required ,to provide service will !be the financial . responsibility of the developer in accordance with the District Rules. and Regulations. All improvements must conform to District Specifications. 3. ' Little Thompson Water District requires-the transfer of one• share of Colorado Big Thompson water for each lot in the commitment. The cost of this water is subject to rebate from the tap fees paid from the development. 4. The installation of a fire hydrant requires payment of .a $2,000. fire hydrant fee .prior to final approval : of the subdivisions . lines. You will be responsible • for any improvements needed to meet the required fire flows in your ' subdivision. 5. In order to provide the required flows to the subdivision you will be required to install a minimum 6" Dia.-.Water line from the intersection of WCR 15 & WCR 54 to the lots you want to serve. The District- may wish to oversize this line for • - future needs. 6. You will be required to provide the needed water lines in the proposed subdivision 7. The design, installation and total cost of the project will be the responsibility-of the developer. It .is possible- that some of the required water lines and - system improvements may be required, built or are being designed by other developers in the same area. If they afe in' place when you need them then you may be able to utilize them to serve your development ( Subject to the' District rebate policy) . It would be wise to-work with the other developers- in the area to ensure' that the water lines installed would be sized to meet the needs of both developments to reduce the amount of duplication an minimize future water line replacement. The rules and regulations regarding Developers transfer of water rights and purchase of taps is changing. The new' policy requires- the developer, to transfer the water shares and then to pay for- the rest of the tap fee as the-water -lines are put in service. • The developer then has the taps to sell with the lots at the price that he sets. The rebate of water rights is eliminated. The transition from. the old policy to the new`! policy allows • the developer to use the old policy up to 1-October-2000. After this date the new policy will be used for all developments. • • 4. 4.1 This commitment letter will expire one year from the date of this letter if the taps have not been purchased, paid for- and installed by that date of expiration. The current fee for the domestic 5/8" X 3/4" tap is $15,000.00. YOU ARE HEREBY ADVISED THAT THE .RULES, REGULATIONS AND TARIFFS OF THE DISTRICT ARE SUBJECT..TO CHANGE WITHOUT NOTICE; AND THIS LETTER .IS ISSUED WITH THE -SPECIFIC LIMITATION THAT THE DISTRICT MAY CHANGE THE RULES, REGULATIONS AND TARIFFS APPLICABLE TO THE ABOVE PROPERTY AT ANY TIME WITHOUT NOTICE TO YOU OR ANY PERSON. If you have questions, please contact me. Regards, • chael T. Cook P.E. District Engineer • • • ' ; i LITTLE THOMPSON WATER DISTRICT WATER TAP APPLICATION TAP NO: TO:Board of Directors,Little Thompson Water District Application is hereby made for domestic water service to the following described property 1010 Legal Owner of Property: A.a}Jvi + D t IL'L 7 l Street Address of Property: /orbr0 C 1/0..); K Kr A - LO 1- ,,4 - L0(G� Z- L! Town and Trp Code: ✓�l/!7'1.3 /kin n. // ge rl3 7 Subdivision: //! // S gotC anicA Lot No: Al Block No: Section: Township:_ North, Range: West of the 6th P.M. County: Applicant understands that if this application is not accepted by the District,or in the event the applicant decides to withdraw this application for water service prior to installation,the tap fee will be refunded to applicant,with the exception of any actual expenses which may be incurred by the District in processing this application. Meter Size Tap Fee 5/S" /g DO 3/4" 1" 1.5" Notes: Tap sizes larger than 2"will be charged a fee as set by the Board of Directors. TAP FEE %_S) ')X . -- IMPACT FEE SPRINKLER TAP FEE Applicant understands that property must be included in the District boundaries for service and agrees to furnish a complete written legal description of the property served prior to tap installation,if so requested. If application for service is accepted,applicant understands that the water service is subject to the rules and regulations of the District,as currently established,or as may be modified in the future by the Board of Directors. A copy of the rules and regulations for the District is available for the applicant,if desired. Applicant certifies that final lot grade will be established prior to installation. The District will not be liable for the f a meter relocation if required after installation due to a than in lot grade. 146.— Ste ( tgnature of Legal Owners) (Signature ofA t) ..2..2)G �//f MM.e. FOR DISTRICT OFFICE USE ONLY ,(Town and Zip Code) Tap Number. Golo tJ ( ^A Area: 303 - 6,- 82. - b 7 / Reed: Si Y). Tap Fee Rd: / & --- (Telephone Number) — Land Included in District District hereby acknowledges receipt of Meter Book: S l 1. 500. — Map Number: Node Number._ /� /,r' Date Tap Installed: �r�,r . . —r , Lt4A k .K. —1 /—1O :Tl:..4.::4 De...rns.:1..�.'..s Tats LITTLE THOMPSON WATER DISTRICT WATER TAP APPLICATION TAP NO: (ij7or) TO:Board of Directors,Little Thompson Water District -- Application is hereby made for domestic water service to the following described property Legal Owner of Property: E 1 l kr e.b ,s / / Street Address of Property: 7O (nD (JC �5L% 4""yy ' ' �- 96 /Town and Zip Code: NT��h s�-r?.i.nz , CoC �'O53 q Subdivision: For P 113-5Ra-v CA Lot No: Block No: - Section: ownship: J North, Range: 67 West of the 6th P.M. County: Applicant understands that if this application is not accepted by the District,or in the event the applicant decides to withdraw this application for water service prior to installation,the tap fee will be refunded to applicant,with the exception of any actual expenses which may be incurred by the District in processing this application. Meter Size Tap Fee 5/8" _. /cz Car 9 ffhl QA 3/4" T� I" 1.5" 2" Notes: Tap sizes 1 a than 2"will be charged a fee as set by the Board of Directors. TAP FEE .7,6/ 02 IMPACT FEE SPRINKLER TAP FEE Applicant understands that property must be included in the District boundaries for service and agrees to furnish a complete written legal description of the property served prior to tap installation,if so requested. If application for service is accepted,applicant understands that the water service is subject to the rules and regulations of the District,as currently established,or as maybe modified in the future by the Board of Directors. A copy of the rules and regulations for the District is available for the applicant,if desired. Applicant certifies that final lot grade will be established prior to installation. The District will not be liable for the expense of a meter relocation if required after installation due to a change in lot grade. (Signature of Legal Owners) (Signature of Applicant) /l//,U Cc-14 4>m' (Symt Address) /7,,�i�dp - „Vao,S- FOR DISTRI OFFICE USE ONLY (Town and Zip Code) Tap Number: IP S T) Area: 3- P ' - '7.320 Tap Fee Recd: $6O (Telephone Number) Land Included in District: District hereby acknowledges receipt of Meter Book S--le/g, <1 - Map Number: Node Number:_ c _ n Date Tap Installed: '/-1,-nit--- Li t) i �n . _02 lob Order#: nZ� S `� ��*� . /C �r LITTLE THOMPSON WATER DISTRICT LI WATER TAP APPLICATION TAP NO: `P r TO:Board of Directors,Little Thompson Water District Application is hereby made for domestic water service to the following described property Legal Owner of Property: n e ht Q. L h-e Y` ` Street Address of Property.k i 70 00 UJC. R 5q Town and Zip Code: ff,,,e�,)''1111 1<)t,j y \ '6053`t) Subdivision: rvYIj - 5 Lot No: Block No: Section: as Township: North, Range: (07 West of the 6th P.M. County: LU-2.Ia Applicant understands that if this application is not accepted by the District,or in the event the applicant decides to withdraw this application for water service prior to installation,the tap fee will be refunded to applicant,with the exception of any actual expenses which may be incurred by the District in processing this application. Meter Size Tap Fee FS Shar � 5/8" -7 500 -4- . CO 511a V e co-Sin si4^ -7 5C-3C) I° Cis 15 3 0 /• 7 2" Notes: T er-than-2-!will_ charged a fee as set by the Board of Directors. T FEE' I 3 C� IMPACT FEE SPRINKLER TAP FEE 9136 that property must be included in the District boundaries for service and agrees to furnish a complete written legal description of the property served prior to tap installation,if so requested. If application for service is accepted,applicant understands that the water service is subject to the rules and regulations of the District,as currently established,or as may be modified in the future by the Board of Directors. A copy of the rules and regulations for the District is available for the applicant,if desired. Applicant certifies that final lot grade will be established prior to installation. The District will not be liable for the expen of a meter relocation if required after installation due to a change i lot grade. igoature of Legal Owners) a o� / (o(Signature etgPf'h`Hoe. l-. + (Sro N-03 m °y FOR DISTRICT 9FFICE USE ONLY 2 /cro"u Zip `) 7E" Pep Number:ri 6 i/ area: "3Q J—LO $ z— I CO Tap Fee Rec'd: 4 /S34° (Telephone Number) Land Included in District: District hereby acknowledges receipt of Meter Book: $ Map Number: Node Number: C - .R: ,fJ Date Tap Installed: `/lnr+-it - :_t X,4 it: `' 2." ft 3-C. LITTLE THOMPSON WATER DISTRICT a e cif WATER.TAP APPLICATION TAP NO: �M 9' TO:Board of Directors,Little Thompson Water District Application is hereby made for domestic water service to the following described property Legal Owner of Property ,r.c4 E L.a r_ Street Address of Property: t"7 0—a, C> (..____) C.. 4. 5 Town and Zip Code: 3 e,)L.r.S T c, w r— CO C 3 t f Subdivision: "— cm, r pg Lot No:oZ Block No: Section:lo( Township: r North, Range: 4"7 West of the 6th P.M. County: Applicant understands that if this application is not accepted by the District,or in the event the applicant decides to withdraw this application for water service prior to installation,the tap fee will be refunded to applicant,with the exception of any actual expenses which may be incurred by the District in processing this application. Meter Size Tap Fee " 5/8 1 :. t S'O G 3/4" 1" 5 1 "^ 2" Col9V) Notes: Tap sizes larger than 2"will be charged a fee as set by the Board of Directors. TAP FEE X �'� 9 U IMPACT FEE SPRINKLER TAP FEE Applicant understands that property must be included in the District boundaries for service and agrees to furnish a complete written legal description of the property served prior to tap installation,if so requested. If application for service is accepted,applicant understands that the water service is subject to the rules and regulations of the District,as currently established,or as may be modified in the future by the Board of Directors. A copy of the rules and regulations for the District is available for the applicant,if desired. Applicant certifies that final lot grade will be established prior to installation. The District will not be liable for the expense a meter relocation if required after installation due to a change in lot grade. A- ,c . aft.A., ..r40.6442,- S t (Si of Legal Owners) (Signature of Applicant) n (Street Address) \ r-,.5L,, C" n c)cis c 9 FOR DISTRICT OFFICE,USE ONLY (Town and Zip Code) Tap Number L c Yt Area: 3r771 — G,C> — 9 G.7 t f Tap Fee Rec'd: 4 t%s S010 (Telephone Number) Land Induded in District District hereby acknowledges receipt of Meter Book: S IS SCY'7 -- Map Number: Node Number:_ Date Tap Installed: 3_`_ _�- l Job Order#: it C. District Representative Date LITTLE THOMPSON WATER DISTRICT L: 3-'�WATER TAP APPLICATION TAP NO: -1 TO:Board of Directors,Little Thompson Water District Application is hereby made for domestic water service to the following described property Legal Owner of Property: r a F_ r t Street Address of Property: `7(3 L c . • Li C C�� Town and Zip Code: 7--> r C 03r , , C c ?'ba 3 V Subdivision: r p m Y r �` Q ,-t, Lot No: -1 Block No: Section: ,)C Township: North, Range:C7 West of the 6th P.M. County: Applicant understands that if this application is not accepted by the District,or in the event the applicant decides to withdraw this application for water service prior to installation,the tap fee will be refunded to applicant,with the exception of any actual expenses which may be incurred by the District in processing this application. Meter Size Tap Fee 5/8" S®G— 3/4" 1" Cot 1.5" I Y" Notes: Ta ' iar-ger_than 2"will be charged a fee as set by the Board of Directors. TAP FEE IMPACT FEE SPRINKLER TAP FEE Applicant ers that property must be included in the District boundaries for service and agrees to furnish a complete written legal description of the property served prior to tap installation,if so requested. If application for service is accepted,applicant understands that the water service is subject to the rules and regulations of the District,as currently established,or as may be modified in the future by the Board of Directors. A copy of the rules and regulations for the District is available for the applicant,if desired. Applicant certifies that final lot grade will be established prior to installation. The District will not be liable for the expense of a meter relocation if required after installation due to a cluing in lot grade. (Signature of Leggy Owners) (Signature of Applicant) Ie• elf r` AvO L r`. (Street c a n`t CC) `?c FOR DISTRICT OFFICE USE ONLY (Tan and Zip Code)I Tap Number: It e,S7 Area: "�O' l des a 9r-; 'C Tap Fee Rec'd: I cz?" So 0 -- (Telephone Number) Land Included in District. District hereby acknowledges receipt of Meter Books C3 ..G( S f�' C — Map Number: .. Node Number:_ ��Date"1h�Inst'alted:' t • '�"" < ! � Q nit Job Order#: 1 Si' 4 District Representative Date LITTLE THOMPSON WATER DISTRICT 6 y 416 WATER TAP APPLICATION TAP NO: 4.4S- Ise Board of Directors,Little Thompson Water District Application is hereby made for domestic water service to the following described property I\ Legal Owner of Property: 1L r-e Fo.,,r Street Address of Property: '/Oa f U... )C___ `s C Town and Zip Code: . --c--') k r-S..*© t_. r. Subdivision: NV—C2)—C2) ` fi h P TS Lot No: 1 Block No: Section:2ot Township: S North, Range: e,--7 West of the 6th P.M. County: Applicant understands that if this application is not accepted by the District,or in the event the applicant decides to withdraw this application for water service prior to installation,the tap fee will be refunded to applicant,with the exception of any actual expenses which may be incurred by the District in processing this application. Meter Size Tap Fee 5/8" l'C i sC 8/4" I" 2" Czb Notes: Tap sizes larger than 2"will be charged a fee as set by the Board of Directors. TAP FEE I scr IMPACT FEE SPRINKLER TAP FEE Applicant understands that property must be included in the District boundaries for service and agrees to furnish a complete written legal description of the property served prior to tap installation,if so requested. If application for service is accepted,applicant understands that the water service is subject to the rules and regulations of the District,as currently established,or as may be modified in the future by the Board of Directors. A copy of the rules and regulations for the District is available for the applicant,if desired. Applicant certifies that final lot grade will be established prior to installation. The District will not be liable for the expense a meter relocation if required after installation due to a change in loy rade. tic (Signature of Legal Owners) (Signature Applicant)t ( Rua? L rve� (stC Q Address) CMS-C)Cr FOR DISTRICT OFFICE USE ONLY (Town and Zip Code) Tap Number: l0GS C e Area: -2-C3.-- — i-S Th • C)cY Tap Fee Rec'd: (Telephone Number) Land Included in District: District hereby acknowledges receipt of Meter Book: S t Q Sr Cc- -Map Number: Node Number._ Date Tap Installed: \ it, / Job Order#: cZa i o-3. District Representative Date
Hello