HomeMy WebLinkAbout20001299.tiff LhaaER OF TRANSMITTAL TO: FROM: FRONT RANGE ROOFING SYSTEMS, INC. Weld County Dept. of Purchasing P.O. BOX 2543 915 10th Street GREELEY, COLORADO 80632 Greeley, Colorado 80631 (970) 353-2322 (303) 893-3908 - Fax ATTN: DATE: 5-4-00 REFERENCE: Marlborough Bldg The following materials are being transmitted to you regarding the referenced project. If you have not received the materials indicated herein, please call our office for verification within ten days of this transmittal; otherwise, we will assume you have received said materials as noted. Thank you. SHIPPED VIA: Mail ENCLOSED UNDER SEPARATE COVER MATERIALS AS NOTED BELOW: ITEM # DATE DESCRIPTION 1 5-4-00 FiberTite 15 year Commercial Roofing for the Marlborough Bldg PLEASE TAKE THE REQUESTED ACTION: APPROVAL REVIEW AND COMMENT NO ACTION REQUIRED FOR YOUR USE (REQUESTED) X RETURN AS REQUESTED FOR BID DUE OTHER ACTION/REMARKS: Enclosed please find the original warranty and a copy. They both need to be signed by an owner. The original is to be retained by the owner and the signed copy needs to be mailed to Seam4n Corp. in the enclosed envelope. Thank you! C COPY TO: SIGNED: ( Link \ 1 C:0YlV(2,r211CenCeO. / .')l/7�7r•fri 2000-1299 C. Cv Kv We ."Fe vv vv ., an ofoo pi,- ar . _ wi `s'/�\/ 13.::' �:.R �,41''1 i... / ,• , .; 't'r ' / 251 if' >+ �.'� �:J \�% F 1161 IITF''WAIF IEF VFNFATF ITF 9TF_ATF AiFae.NE:W VP W WriiF'9TF aVF.W /F WE''W.:VFW 41F ga ''sf 14 li \ e St m , . o Seaman �eaite Corporation WARRANTY FOR COMMERCIAL ROOFING ROOFING SYSTEMS 40 a /, W Weld County li ;ap 9,000 �V t Sodding Ovmelt'>l/ame �— area of Roofing Project ! , W 915 10th Street, Greeley CO. Torn Ghidotti ' . 24 'Budding Owner's Address Seaman Corporation Inspector 711 r \�/iSit Marlborough Building, Greeley CO. 04—26—2000 V I �. Address&Location ofBuu1drng Date of Comp/tion an/Acceptance as(,. -, >\)v�' T SEAMAN CORPORATION warrants to the owner named above ('Owner') of the building described herein that, subject ?ft t., '\` it..: to the Terms, Conditions, and Limitations set forth below, for a period of Fifteen (i5) years commencing with the date ,U >. F of final inspection and acceptance. Seaman Corporation will repair any leaks in the FiberTite Roofing Systems furnished to 'w >v+) F said commercial building attributable to Roofing Membrane provided by Seaman Corporation and/or defective T;. ,. . workmanship provided by Seaman Corporation or its authorized FiberTite Single Ply Roof Applicator. oU a Terms, Conditions & Limitations y , ,(/;\ W I. The Roofing System must have been installed by an Authorized FiberTite Single Ply Applicator and must have been inspected and approved for y ���0. warranty by Seaman Corporation_ This warranty issuance will not relieve the installation contractor from performing additional work should final II :/ i inspection discover any failure to comply with Seaman specifications or shortcomings in workmanship. _ p� 9 2 Throughout the term of this warranty,Seaman Corporation shall be given free access to the roof of the commercial building described herein during 71 .":',/4 .77.......„,,,,p. regular business hours. 4 / R= 3. The Owner shall obtain Seaman Corporations prior written approval before making any alterations of said roof or installing any structu-es, fixtures on e y rt or through said roof. F 0. Seaman Corporation shall have no obligation under this warranty until all bills for installation, supplies and service have been pail in full to the ft \.'4 ././...,,,. .. . .. Authorized FiberTite Single Ply Roof Applicator and any material suppliers.including Seaman Corporation. 4 S 1 F 5. Owner shall give Seaman Corporation written notice at its address set forth herein not more than thirty(30)days after discovery of any leaks'n the ' tip fp Roofing System. . p\,;r (r & if,after inspectlon by Seaman Corporation,leaks in the Roofing Membrane System are found,in good faith determination of Seaman Corporation, to 4 +% Y,' be the result of defects in the Roofing Membrane provided to the Owner by Seaman Corporation and/or the workmanship orovided be Seaman 'y l' ' ` 1117. Corporation and/or and Authorized FiberTite Single Ply Roofing System Applicator,Seaman Corporation will repair any leaks in the Roofing System at •Y' fed its expense but in no event shall Seaman Corporation's obligation over the lifetime of the warranty exceed the Owner's original cost of the installed roof. % R. 7.The Owner will be responsible for the cost of investigation if any leak is determined not to be covered by this Agreement. 4 %k :, U.' 8. The warranty stated herein is the SOLE AND EXCLUSIVE REMEDY for failure of the Roofing System SEAMAN CORPORATION SHALL UNDER yz '3` Y NO CIRCUMSTANCES BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO DAMAGES TO /Vr OTHER COMPONENTS OF THE ROOF,THE COMMERCIAL BUILDING DESCRIE3ED HEREIN OR THE CONTENTS OF SAID BUILDING . �\ 1 M 0.This warranty shall not be applicable to nor shall Seaman Corporation be responsible for damage or loss caused in whole or in part by V : 4 . natural disasters inducing, not limited to bghtning,hurricanes,tornadoes or earthquakes;vandalism,cMil dsobedience or acts of war;alteration of the roof or installation of structures. y� r 1T' fixtures or utilities on or through the roof without the prior wntten approval of Seaman Corporation as previously slated in section three(3t..settling,warping,defective condition,corrosion, .- \\i/V{ or other failure of the structure or substrata to which the Roofing System is attached;any chemical contaminants injurious to the Roof System that have not been specifically approved by I4 \ the company via the Materials Submittal&Warranty Request form;negligence or failure by the Owner or any lessee to reasonably maintain the roof;traffic or s--:orage at materials on the I•.- r 4 1 ' ' tool,infiltration or condensation of moisture in,through,around or above the walls of the building;acts of negligence or misuse by the Owner or any othery tC Corporation,or an Authoneed FiberTite Single Ply Roof Applicator,and/or failure of any matedal or component party other than Seaman .� bo not furnished by Seaman Corporation. • ilar4 /{' 'le. This agreement may be assignable to a subsequent building Owner,only if the above named owner requests in writing that Seaman Corporation y �\ consent to an assignment of this warranty to the purchaser of the building from Owner,which consent will not be unreasonably withheld. li O. / L 'I1. SEAMAN CORPORATION MAKES NO WARRANTY THAT THE ROOFING SYSTEM IS MERCHANTABLE OR FIT FOR ANY PAR TICUI AR 'r N . !r, PURPOSE, THERE BEING NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE FACE HEREOF. NO EMPLOyEF OR �L/ REPRESENTATIVE HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OTHER THAN THOSE STATED HEREIN.1 Ir! ay ',1/4,:.'„4. 0 l .,' v SEAMAN CORPORATION T�� - - f r Building Owners*nature (05710* ByHs: !R X� i a 672f7 — — n/a +t rr r ; R Title Dal .tit \ i;. _ ''t 4 7n>.::.,<: V' Warranty Exclusions p F n/a Note Roofing installations for personal,family or household X�;. purposes ARE NOT WARRANTED HEREUNDER. i 9 — . ';4 P/ IZ Warranty Inclusions y Serial No. 2000440 S } \ 1000 VENTURE BLVD.'WOOSTER, OH 44691 I a b .:',•::,.. it 31tr-a4k Ate:Atli Al .4.k.-41& 91& iite sit I1& 91& 9rF69fk;9/k,s s&.SEk,M 94:Mk st11:9ik;sa i ilk:41Rr8 ,,:,-)AN et Seaman Corporation Innovative Customer Solutions through Fiber and Polymer Technology 1000 VENTURE BLVD. • WOOSTER, OHIO 44691 • TELEPHONE(330)262-1 I I I • FAX(330)263-6950 TO: FiberTite Applicators FROM: Jerry Beall RE: FiberTite Warranty Congratulations of the completion of another FiberTite® Single-Ply Roof System. Please find enclosed the warranty for the FiberTite System. You will find the original warranty and two copies. One copy is for your records; one copy and the original warranty are to be signed by the building owner. The building owner should retain the original and send the signed copy to Seaman Corporation for our records. I have enclosed a self-addressed envelope for your convenience in returning our copy. I would like to thank you in advance for your cooperation and help with the completion of the warranty. Sere , Jerry Beall Technical Service Manager JB/jrg Enclosures ® FiberTite Is a registered trademark of Seaman Corporation We are an Equal Opportunity Employer, M/F/H/V.' Seaman Corporation Fiber Tite ROOFING SYSTEMS MANUFACTURER OF FIBERTITE SINGLE PLY ROOF 1000 VENTURE BLVD. • WOOSTER, OHIO 44691 • TELEPHONE 800-927-8578 • FAX (330)263-6950 FIBERTITE® ROOFING SYSTEMS ROOF MAINTENANCE PROGRAM TO: The Building Engineering and/or Maintenance Department The FiberTite Single-ply Roof System has been engineered and installed to service your building for many years to come The Seaman Corporation manufactured membrane consists of a puncture and abrasion resistant fabric with an ethylene inter-polymer (EIP)coating that can withstand harsh weathering and environmental hazards that most roof coverings are Incapable of enduring. However, to obtain optimum performance from your FiberTite roof, it is important to establish a regular maintenance schedule to insure that your building roof is free of any conditions that can cause unnecessary injury to the roof deck, leading to expensive repairs and possible damage to the building interior. One of the first and best rules to follow in protecting your roof is to establish a policy of keeping unauthorized people off your roof and to minimize the number of service personnel trips on your roof. Put locks on all doors leading to your roof as well as post a sign that disallows entrance to unauthorized personnel. We have enclosed pressure sensitive labels that should also be posted on your roof exit doors and refers to the slippery nature of the FiberTite Single-ply Roof when it becomes wet from rain, snow, or ice conditions. Proper safety shoes should be worn if it is imperative that roof top work be accomplished under these weather conditions. It you have a busy roof, i.e., one with much foot traffic, you should install walkways on the roof. This action will minimize the opportunity of any unnecessary damage to the FiberTite membrane. The major items to check for during a roof maintenance inspection are: punctures in the membrane sheet; open seams at the membrane overlaps and at the roof penetrations (soil stacks, curbs, platforms, etc.) as well as the parapet walls and/or edge details(use a blunt instrument,such as a screw driver, to inspect seam integrity);caulking at the termination bars,surface mounted reglet and pitch pan sealants, any loose fasteners and nails, both on the roof field itself as well as on the wall and edge details and check to assure that drains and gutters are unclogged and that there is no water ponding on the roof that requires remedial action. It is important to consider the roof covering whenever you should add new products and or processes to your building operation that will allow for chemical contaminant venting onto your roof. For that reason we have listed below the chemicals that can cause harm to the FiberTite roof covering, especially if left ponding for several months. It is equally important to determine the com- patibility of the roof system should the building be used for any purpose other than what was ongoing or planned when the roof covering system was selected and installed. This important fact is often overlooked when a building is converted for a new purpose. Any installation of new roof top equipment, such as air conditioning equipment and the like, requires the service of a FiberTite contractor to install new fleshings and the like to assure that no harm is caused to the integrity of the roof covering. You should discuss with your local authorized FiberTite roofing contractor a maintenance service contract which allows for professional annual inspections and immediate corrective action for any potential roof damaging problems. Your authorized FiberTite contractor has been selected because of his thorough knowledge of roof top technology and full service professional abil.ties solving and eliminating roof damaging problems. Contact your FiberTite representative or FiberTite Technical Service Depart- ment for any assistance in locating these authorized contractors or for any questions about FiberTite Roofing System you need answered. Harmful chemicals if left standing on FiberTite for a prolonged period of time: Acetic Acid Aromatic Hydrocarbons Asphalt Materials Benzene Chiorox Cooking Oil above 1400F. Ethyl Acetate Furfural Gasoline Methyl Ethyl Ketone (MEK) Nitric Acid Paint Thinners Phenol Phosphoric Acid 750/0 Phthalate Plasticiser Above 2000F Solvent Degreasers Toluene Zylene =iberTite is a registered trademark of Seaman Corporation Seaman Corporation Fiber Tite ROOFING SYSTEM MANUFACTURER OF FIBERTITE SINGLE PLY ROOF • 1000 VENTURE BLVD. • WOOSTER,OHIO 44691 • TELEPHONE 800-927-8578 • FAX(330)263-6950 Web Site:Please visit us at www.seamancorp.com PARTIAL CHEMICAL REAGENT LIST COMPATIBLE WITH FIBERTITE® MEMBRANE Ammonium Phosphate Kerosene Ammonium Sulphate Magnesium Chloride Antifreeze (Ethylene Glycol) Magnesium Hydroxide Animal Oil Methyl Alcohol ASTM Fuel A Mineral Spirits ASTM Oil #2 Naptha Calcium Chloride Solutions Lactic Acid Calcium Hydroxide Phosphoric Acid (50%) (100%) 20% Chlorine Solution Potassium Chloride Clorox Potassium Sulphate Conc. Ammonium Hydroxide Raw Linseed Oil Corn Oil SAE-30 Oil Crude Oil Salt Water Diesel Fuel Sea Water Ethyl Alcohol Sodium Acetate Solutions Fertilizer Solution Sodium Bisulphate Solutions #2 Fuel Oil Sodium Hydroxide (60%) #6 Fuel Oil Sodium Phosphate Glycerin Sulfuric Acid (50%) Hydraulic Fluid 50% Tanic Acid Hydorchloric Acid (50%) Transformer Oil Hydrofluoric Acid (5%) Transformer Oil (PCB) Hydrofluoric Acid (50%) Turpentine Hydrofluosilicic Acid (30%) Urea Formaldehyde Ivory Soap Vegetable Oil JP-4 Jet Fuel Zinc Chloride The above compatibility list must be conditioned by chemical concentrate percentage and temperature. For example, if animal fats are vented through the stack at high temperatures, 2OO0F, the membrane may be scorched and damaged. Please send to our attention any specific data pertinent to your needs for us to analyze. FiberTite is a registered trademark of Seaman Corporation ROOFING SYSTEMS Patent No.4,546,589 ACCESS RESTRICTED TO AUTHORIZED PERSONNEL PLEASE OBSERVE THE FOLLOWING PRECAUTION STAY ON WALKWAYS WHEN PROVIDED ROOF IS SLIPPERY WHEN WET NO SMOKING PROTECT THE MEMBRANE SHOULD EXTENSIVE ACTIVITY BE RE PLEASE NOTIFY THE OWNER SHOULD ACCIDENTAL DAMAGE C PLEASE NOTIFY THE OWNER SHOULD ANY DAMAGE BE OBE FOR WARRANTY SERVICE CONTACT: SEAMAN CORPORATION FIBERTITE CUSTOMER SERVICE 800 / 927-8578 Hello