Loading...
HomeMy WebLinkAbout20001030.tiff - tli‘1";' Memorandum WI I CTO: Chris Gathman, W.C. Planning COLORADO DATE: February 9, 2000 cfel FROM: Sheble Mcconnellogue, W.C. Environmental Services CASE NO.: USR-1263 NAME: Wright, Tracy Environmental Health Services has reviewed this proposal for a vehicle restoration home business. The following conditions are recommended to be part of any approval: 1) All liquid and solid wastes (as defined in the Solid Wastes disposal Sites and Facilities Act, 30-20-101, C.R.S., as amended) shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. 2) No permanent disposal of wastes shall be permitted at this site. 3) Waste materials shall be handled, stored, and disposed in a manner that controls fugitive dust, blowing debris, and other potential nuisance conditions. 4) The maximum permissible noise level shall not exceed the residential limit of 55 db(A) as measured according to 25-12-102, Colorado Revised Statutes. 5) The facility shall utilize the existing septic system(G19759689). 6) All pesticides, fertilizer, and other potentially hazardous chemicals must be stored and handled in a safe manner. Reference 25-8-205.5 Colorado Water Quality Control Act and Rules and Regulations thereof. 7) The facility shall utilize the existing public water supply (Left Hand Water District). 8) Prior to recording the plat, the applicant shall submit a waste handling plan to the Environmental Health Services Division of the Weld County Department of Public Health& Environment. The plan shall include at a minimum, the following: 1) A list of wastes which are expected to be generated on site (this should EXHIBIT include expected volumes and types of waste generated). 2) A list of the type and volume of chemicals expected to be stored on site. 3) The waste handler and facility where the waste will be disposed (including the facility name, address, and phone number). 9) The facility shall be in compliance with the Colorado Air Quality Control Commission Regulations. SM/vhl091 2000-1030 0 RECEIVED FEB 0 4 2000 WELD�°Weld PUBLIC e County Referral 1 February 1, 2000 e COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Tracy Wright Case Number USR-1263 Please Reply By February 22, 2000 Planner Chris Gathman • • Project USR for vehicle restoration as a home business. • • Legal Lot 15, Block 4, Carmacar Ranchettes; E2 of Section 5, Township 1 North, Range 68 West of the 6th P.M., Weld County, Colorado. • Location West of WCR 5 and south of SH 52. Parcel Number 1467 05 401016 • The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) April 18, 2000 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. Al See attached letter. Comments: Signature �'J ! CaU /'(/,'Jr/� Date O3 � _ b3' � AgencyL� `rte Po�,j +Weld County Planning Dept. +1555 N. 17th Ave.Greeley,CO.80631 +(970)353-6100 ext.3540 +(970)304-6498 fax ,. � MEMORANDUM TO: Chris Gathman, Planner DATE: March 6, 2000 FROM: Donald Carroll, Engineering Administrator p • COLORADO SUBJECT: USR-1263, Tracy Wright The Weld County Public Works Department has reviewed this proposal. This project falls primarily under the purview of the Weld County Zoning Ordinance Use by Special Review Standards for vehicle restoration as a home business. Our comments and requirements are as follows: COMMENTS: Lot 15, Block 4 of the Carmacar Ranchettes Subdivision is the location of this Use by Special Review. This subdivision is maintained by Weld County. REQUIREMENTS: Mountain View Street is a gravel street which has been dust controlled. The applicant shall utilize the existing access with no additional accesses granted. There shall be no staging, storage, or parking of vehicles on Mountain View Street. The plat drawing is identifying a fence within the 80-foot right-of-way of Mountain View Street. This fence shall be relocated because Weld County does not allow any fence structures within the right-of-way. Storm Water Drainage: The applicant is indicating that there will no change to the storm water drainage pattern. No additional buildings, asphalt, or improvements are being proposed so Weld County has no conflict with drainage. cc: USR-1263 'Mg pe plan" G plan5usr nn pp$. 0� 2000 EN ED REC EXHIBIT 1/1 -613/4;:\\ Geld County Planning L FEB 14 20 Weld County Referral RECEIVED February 7, 2000 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Tracy Wright Case Number USR-1263 Please Reply By February 22, 2000 Planner Chris Gathman Project USR for vehicle restoration as a home business. Legal Lot 15, Block 4, Carmacar Ranchettes; E2 of Section 5,Township 1 North Range 68 West of the 6th P.M., Weld County, Colorado. Location West of WCR 5 and south of SH 52. Parcel Number 1467 05 401016 The application is submitted to you for review and recommendation. My comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing(if applicable) April 18,2000 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. XSee attached letter. Comments: \�l Signature Date y • y Agency � V�e a T'� re_ \I-3 4Weid County Planning Dept 41555 ft 17th Ave.Greeley,CO.80631 4(970)3536100 ext.3540 6(970)304-6498 fax EXHIBIT g,OUNTA44 MOUNTAIN VIEW FIRE PROTECTION DISTRICT E Administrative Office: 9119 County Line Road• Longmont, CO 80501 e �+ F (303) 772-0710• FAX (303) 651-7702 VIEW February 11,2000 Mr. Chris Gathman Weld County Planning Department 1555 North 17th Avenue Greeley,CO 80631 Dear Mr. Gathman: I have reviewed the submitted material pertaining to the Use by Special Review for the restoration of vehicles at 1906 Mountain View Street(Case Number: USR-1263, Case Name: Tracy Wright). The site is within the boundaries of the Mountain View Fire Protection District and receives service from the District. The Fire District is opposed to this request as proposed. The restoration and repair of vehicles must be conducted in a building meeting the Uniform Building Code (UBC)requirements for a Group H(Hazardous), Division 4 Occupancy. The pole barn was probably built in accordance with the UBC for an agricultural building(Group U Occupancy- Weld County Permit#BC- 9800835) and as constructed, is not designed for the proposed use. This would constitute a "Change in Use"for the structure which would have to be approved by the Weld County Building Department. The painting of vehicles is considered as an "Application of Flammable Finishes" in accordance with the Uniform Fire Code (UFC). This is a hazardous activity and must be conducted within a building meeting the requirements of a Group H, Division 2 Occupancy or a listed spray booth. Again, the pole barn is an inappropriate structure for this type of activity. We appreciate being involved in the planning process. Should you have any questions, please contact me at(303)772-0710. Sincerely, LuAnn Penfold Fire Marshal LMP/Ip cc: Dennis Renley, Weld County Building Department, 1555 N. 17th Avenue,Greeley, 80631 Tracy Wright, 1906 Mountain View Street, Erie,CO 80516 project file file 1O2.12.00 Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 9119 Cnty Line Rd. 10971 WCR 13 P.O.Box 575 P.O.Box 11 10911 Dobbin Run P.O.Box 666 P.O.Box 40 Longmont,CO Longmont,CO 299 Palmer Ave. 8500 Niwot Road Lafayette,CO 600 Briggs 100 So.Forest St. 80501 80504 Mead,CO 80542 Niwot,CO 80544 80026 Erie,CO 80516 Dacono,CO 80514 Weld County Referral February 1, 2000 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Tracy Wright Case Number USR-1263 Please Reply By February 22, 2000 Planner Chris Gathman • • • Project USR for vehicle restoration as a home business. • Legal Lot 15, Block 4, Carmacar Ranchettes; E2 of Section 5, Township 1 North, Range 68 West of the 6th P.M., Weld County, Colorado. Location West of WCR 5 and south of SH 52. Parcel Number 1467 05 401016 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) April 18, 2000 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. Comments: • Xu . flQ y 214 (fr/ 7& & a yr- Signature -fit„ /t () Date 0.2/06) Agency 7giun 79t /. ei +Weld County Planning Dept. +1555 N. 17th Ave.Greeley,CO.80631 +(970)353-6100 ext.3540 •:•(970)304-6498 fax EXHIBIT ( 3 (1)ce DEPARTMENT OF BUILDING INSPECTION 1555 N. 17TH AVENUE GREELEY, COLORADO 80631 PHONE (970) 353-6100, EXT.3540 FAX (970) 304-6498 'lige COLORADO April 7, 2000 Tracy Wright USR-1263 Repair garages are classified as an H-4 Occupancy with paint booths normally classified as H-2 Occupancies. 1. Occupancy separations shall be provided between the repair area, paint booth and any other Occupancies as required in Table 3-B of the 1997 Uniform Building Code (UBC). Section 302.1, Exception 1 of the UBC, states: When an approved spray booth constructed in accordance with the Fire Code is installed, such booth need not be separated from Group B, F, H, M or S Occupancies. Spray booths shall be installed as required by the manufacturer or as specified by the Mountain View Fire District. Spray booth electrical wiring shall be according to Article 516 of the 1999 National Electrical Code (NEC). 2. An automatic fire-extinguishing system shall be installed in Group H, Division 4 Occupancies having a floor area of more than 3,000 square feet. 3. Either natural or artificial light shall be supplied equal to 1/10 the floor area. 4. Either natural or mechanical ventilation shall be supplied equal to 1/20 of the floor area. 5. Any devices that generate a glow, spark, or flame capable of igniting flammable vapors shall be installed with sources of ignition at least 18 inches above the floor. 6. Any rooms containing large amount of flammables or where flammables are mixed or dispensed may need to be in a control area. (Check with fire district for recommendations.) EXHIBIT Service,Teamwork, Integrity, Quality � I� 7. Floors in areas where motor vehicles, boats, helicopters or airplanes are stored, repaired or operated shall be of noncombustible, liquid-tight construction. 8. Depending on quantities of liquids that are stored, spill control may be required. 9. Distances from property lines and adjacent buildings shall be as outlined in Section 307.3 and 503 of the UBC. 10. Group 11, Division 4 Occupancies with 1,000 square feet or more shall provide two separate exits for every portion of that Occupancy having a floor area greater than 200 square feet. 11. Plans shall be submitted to Mountain View Fire District for review. 12. Additional requirements or changes may be required when building applications or complete plans are reviewed by the Weld County Building Inspection Department or the Mountain View Fire District. Sine, ply, S.ra� Building Official Service,Teamwork, Integrity,Quality Hello