HomeMy WebLinkAbout20001015.tiff if & MEMORANDUM TO: Sheri Lockman DATE: January 25, 2000 O FROM: Sheble McConnellog e, Environmental Health • COLORADO SUBJECT: Parsons, Robert / Skylark Ranch CASE: Z-536 Environmental Health Services has reviewed this proposal for a 5 lot Minor Subdivision. The following conditions are recommended to be part of any approval: 1. A Weld County Septic Permit is required for the five proposed home septic systems. All systems shall be installed according to the Weld County Individual Sewage Disposal Regulations. 2. The proposed minor subdivision shall be served by a public water suppy (North Weld Water District). sm/637 ad County Planning Dei.iL, JAN 2 } OOC. RECEIVED .-000-1 " 5 EXHIBIT l � a cid County Planning Dept.. 4114 iEB 032000 R E c E E V weld County Referral O January 10, 2000 • COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Robert L. Parsons-Skylark Case Number Z-536 • Ranch Please Reply By January 31, 2000 Planner Sheri Lockman Project Minor Subdivision Change of Zone from Agricultural to Estate. Legal Lot B of AmRE-2357; Part of the SE4 & SW4 of Section 8, Township 7 North, • Range 67 West of the 6th P.M., Weld County, Colorado. Location Approximately 800' north of Hwy 14 and approximately 1/2 mile east of WCR 15. • Parcel Number 0705 08 000029 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) March 21, 2000 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. Comments: rke. P. F. 4. Gnm ern es re.vra.rt J-4.. n"e.-. z.s bias he.e., ptraus/y dorawe.,f've(. Fin 5pneru..•s an rflatr4 (Sea Afar. "4 ere ewe s boorsiraj, Signature gtiew 0 _ e ksf. Ere /K7.er4af Date Z- r-n Agency Povdre Flit Fit 141•"4'1 _ • •:•Weld County Planning Dept. :•1555 N. 17th Ave. Greeley,CO. 80631 +(970) 353-6100 ext.3540 :•(970)304-6498 fax / /7 a re; TO: Sheri Lockman, Planning Department WoFROM: Lee D. Morrison, Assistant Weld County Attorney C. DATE: March 7, 2000 COLORADO SUBJECT: Skylark I have seen North Weld's form but I do not recall this project. 1. The developer has to pay construction costs within the development. 2. The agreement requires payment of"plant investment fee" portion of"tap fee" to he paid before water lines can commence. 3. The developer has to pay $15,000 of participation costs. This agreement works if item #1 costs are included in improvements agreement with the County and items 2 and 3 are paid or otherwise guaranteed prior to recording of plat. 1 27/Otiv l.ee'D. Morrison Assistant Weld County Attorney 1LDM/db:Memo/Skylark.wpd r n raid Goan' PlaMinE aP Ogto cEIv ' ` riE EXHIBIT i AL a (71, DEPARTMENT OF BUILDING INSPECTION 1555 N. 17TH AVENUE GREELEY, COLORADO 80631 I PHONE (970) 353-6100, EXT.3540 �• FAX (970) 304-6498 COLORADO March 7, 2000 Robert L Parsons-Skylark Ranch 5 lot Minor Subdivision Z-536 1. Proper building permits shall be obtained prior to any construction or excavation. 2. Building permits are required for any accessory buildings being constructed or moved onto the property. 3. The preliminary geotechnical from EEC indicates there may be some on-site soils that have a potential to swell. Building sites may also contain shallow ground water. Basement or crawlspace foundations may not be feasible for all sites. The report also recommends only "light load residential structures." All principal dwellings will be required to have engineered foundations which are designed with these concerns in mind. I strongly recommend that each foundation he based on a site-specific geotechnical report. The Weld County Building Code Ordinance does allow an "open hole inspection," performed by a Colorado licensed engineer, in place of a site-specific geotechnical report. 4. All fill materials upon which buildings or structures rest, shall be compacted to a minimum of 90% of maximum density. Detrimental amounts of organic material shall not be permitted in fills. No rock or similar irreducible material with a maximum dimension greater than 12 inches shall be buried or placed in fills. A compaction report provided by a Colorado licensed engineer will be required in such situations. 5. All buildings or structures shall maintain distances from property lines and adjacent buildings as outlined in Table 5-A of the 1997 Uniform Building Code. Service,Teamwork, Integrity, Quality 1 19 Page 2 6. Additional requirements may be provided from the Poudre Valley Fire Protection District. 7. At the time an application is accepted for a building permit a plan review will be done. A complete review of the building or structure may reveal other building issues or areas needing attention. Respe tfu \ Da,s_§_pEaas. t31-1 Building Official Service,Teamwork, Integrity, Quality MEMORANDJM TO: Sheri Lockman DATE: March 27, 2000 FROM: Diane Houghtaling, Traffic Engineer SUBJECT: Z-536:Skylark Ranch The Weld County Public Works Department has reviewed this Minor Subdivision. Our comments and requirements are as follows: COMMENTS: This subdivision's entrance is too close to the irrigation ditch. In addition, the curves immediately south of the entrance are very sharp. This combination could result in a vehicle leaving the road and ending up in the ditch. Public Works requests the entrance be moved to the west to allow at least thirty (30) feet of separation between the entrance and the ditch. This adjustment will require an amendment to the Recorded Exemption. I have talked with the developer and Planning Staff and this solution appears feasible to both parties. The entrance to this subdivision will be off SH 14. The developer will be required to obtain an Access Permit from the Colorado Department of Transportation. This permit may include: speed change lanes, asphalt or concrete surfacing, right-of-way reservations and turn radius improvements. A copy of the permit will provided to the Department of Planning Services before recording of the final plat. The maximum block length for subdivision roadways is 1500 feet. The internal road in this subdivision will require a turn-around at or before the 1500 foot maximum. The present location is not acceptable. This project is in the Windsor Service Area Road Impact Fee District. An Improvements Agreement shall be completed by the developer prior to recording the Final Plat. This form is provided by the Department of Planning Services. The developer shall complete this form showing the improvements that the applicant is require to construct (including Access Permit requirements) and the type of collateral which will guarantee installation of said improvements. If you have any questions, please contact Diane Houghtaling, Traffic Engineer, at (970)356-4000 Ext. 3788. pc: Z-536 M:\W PFI LES\d is ne\z-536a.wpd • �D Hello