Loading...
HomeMy WebLinkAbout20031312.tiff REFERRAL LIST NAME:Weld County CASE NUMBER: USR-1424 REFERRALS SENT: March 20, 2003 REFERRALS TO BE RECEIVED BY:April 18, 2003 COUNTY Ambulance Services TOWNS and CITIES Attorney _Ault _X Health Department Brighton Extension Service Broomfield Emergency Management Office Dacono _X Sheriffs Office Eaton _X Public Works Erie Housing Authority Evans Airport Authority Firestone _X Building Inspection Fort Lupton Code Enforcement Frederick STATE Garden City Division of Water Resources Gilcrest Geological Survey _X_Greeley Department of Health Grover Department of Transportation Hudson Historical Society Johnstown Water Conservation Board Keenesburg Oil and Gas Conservation Commission Kersey Division of Wildlife: LaSalle Loveland Lochbuie Greeley Longmont Division of Minerals/Geology Mead FIRE DISTRICTS Milliken Ault F-1 New Raymer Berthoud F-2 Northglenn Briggsdale F-24 Nunn Brighton F-3 Pierce Eaton F-4 Platteville Fort Lupton F-5 Severance Galeton F-6 Thornton Hudson F-7 Windsor Johnstown F-8 La Salle F-9 Mountain View F-10 COUNTIES Milliken F-11 Adams Nunn F-12 Boulder Pawnee F-22 Larimer Platteville F-13 Platte Valley F-14 FEDERAL GOVERNMENT AGENCIES Poudre Valley F-15 US Army Corps of Engineers Raymer F-2 USDA-APHIS Veterinary Service Southeast Weld F-16 Federal Aviation Administration Windsor/Severance F-17 Federal Communication Commission Wiggins F-18 Union Colony F-20 SOIL CONSERVATION DISTRICTS _X Western Hills F-20 Brighton OTHER Fort Collins 2003-1312 School District _X Greeley Ditch Company Longmont West Adams COMMISSION/BOARD MEMBER I _X_Fred Walker Weld County Planning Department GREELEY OFFICE a APR X 7 2003 • Pf ir RECE VE � ' Weld D Referral March 20, 2003 C. COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Weld County Case Number USR-1424 • Please Reply By April 18, 2003 Planner Sheri Lockman Project Site Specific Development Plan and a Special Review Permit for a business permitted as a use by right or accessory use in the Commercial Zone District (Food Warehouse) in the A(Agricultural)Zone District. Legal Lot 2 as shown on RS-1023; Re-subdivision of Union Colony Subdivision; being part of Section 27, T6N, R67W of the 6th P.M., Weld County, Colorado. Location West of 111h Avenue and Southwest and adjacent to North 17'"Avenue. Parcel Number 0803 31 401009 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) May 6, 2003 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ Jr.Ve have reviewed the request and find no conflicts with our interests. See attached letter. Comments: Signature Date o Agency CAL) oG Greek7 v:s P/cn�,h5 in<' ro--t +Weld County Planning Dept. +1555 N. 17th Ave.Greeley, CO.80631 +(970)353-6100 ext.3540 +(970)304-6498 fax OFFICE OF COMMUNITY DEVELOPMENT . , Planning Division .-. 1100 10th Street, Suite 202, Greeley, Colorado 80631 • (970)350-9780 • Fax(970)350-9800 • www.greeleygov.com Grty eet f Greeley Weld County Planning Department April 15,2003 GREELEY OFFICE APR 1 7 2003 RECEIVED Sheri Lockman Weld County Planning Department 1555 N. 17°Avenue Greeley, CO 80631 Subject: USR-1424 Weld County Food Bank Ms. Lockman, Thank you for the opportunity to comment on this Use by Special Review. The City of Greeley reviewed ^ this site plan through its Administrative Review Team(ART)process in March. A copy of the ART comments and copies of the applicable Development Code standards are attached. These comments were previously provided to Mr. Mark Kiefer. As you are aware,this property will be receiving funding from the Greeley Urban Renewal Authority (GURA),will be receiving City of Greeley water and sewer service, and will be annexed into the City later • this year. Because of these factors,the City of Greeley is expecting that the building will be built to City of Greeley standards, including its architectural standards. Your help in ensuring that these standards are adhered to is appreciated. Please call me at 350-9276 if you have any questions. Sincerely, Michael Whitley Planner II EXHIBIT SERVING OUR COMMUNITY • I T ' S A TRADITION 719e promise to preserve ancfirnprove laze patty of[IA for. Greeley lArotigl; ely, courteous and cosi e�feclioe service. Project Review Comments City of Greeley Project Name Weld County Food Bank (537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # 1 Reviewed By Bill Andrews Department PW Transportation Date 3/17/2003 Traffic Study Page O 1. Provide estimated daily and peak hour traffic generation and time of the peak. 2. The layout does not show"H"Street, the driveways off of"H"or surrounding land use or their driveways. Provide this. All drive isles off the driveway should be at least 60'back from "H"Street. 3. Delivery trucks must be able to move and back-up to the dock within the site. The plan shows the dock, but no room is shown to back up, or exit. What size trucks will be there? Show their path to dock. Monday,March 17,2003 Page 1 of 9 Project Review Comments City of Greeley Project Name Weld County Food Bank(537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # 1 Reviewed By Wendy Daugbtry Department Water&Sewer Date 3/17/2003 Page O The Water and Sewer Dept has no comment on the USR request. WNp�iWfliS�bif�MN1BMfRaeiOlpkdl'lxicio+iws;N;wiatnWY-nur.,.aeew.w�srxxnw+c.xrN!rP.r,lYsew.+nv�?Y!exw:uMNN,uurw»ntraszrracn,,.,.«:.aur.�.rn,.«nr.:+>�s+w«+w:.:rya...«.�.!-ncan.an..�.....wi.�-f::.- ......,...,n.. Monday,March 17,2003 Page 2 of 9 Project Review Comments City of Greeley Project Name Weld County Food Bank(537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # 1 Reviewed By Don Dunker Department PW Design/Review Date 3/17/2003 A. General Page 1 ❑ New 1. Per FIRM Panel 080266-0628C and Floodway Panel 080266-0004 indicate this property is within the 100-yr flood plain. Preliminary approval of this project will not be given until the Federal Emergency Management Agency(FEMA)has revised the existing floodplain maps. To change the existing floodplain and floodway maps a Conditional Letter of Map Revision (CLOMR)should be initially submitted to FEMA to reflect proposed grading changes to the 100-year floodplain. Once the CLOMR is approved by FEMA and the City of Greeley, the proposed grading changes can be constructed and a Letter of Map Revision (LOMR)must be submitted and approved by FEMA with the support of the community. Once the LOMR is approved, construction of residential housing may begin. Based on conversations with FEMA, buildings cannot be constructed in the 100-year floodplain whether you fill the entire lot or just the building pad. The structures could also include basements after the 100-year floodplain has been revised even though the elevation of the basement is below the base flood elevation, as long as the Minimum Opening (MO) elevations are 1-foot above the 100-year floodplain elevation. 2. After the revision to the 100-year floodplain is approved, the requirement for floodplain insurance will then be dictated by the lending agencies based on the location of the property and the revised 100-year floodplain. Some lending agencies may still require floodplain insurance if only a portion of the lot is within the 100-year floodplain, even though the building pad is not within the 100-year floodplain. Please be advised this process can take up to 2 years. 3. Ponds with berms will not be allowed within the 100-yr flood plain. Ponds that have dished out areas will be acceptable. B. Drainage Report r� ....::.. u:_::,.z�..• _ +- ..,..•. rn- .; .u:+v,Ka•a.w....+.w«.rHnuu .w.rrur»cwv.ra;_:v+..w,..^.s....n==r:r..,anxx,... ,:rte::... Monday,March 17,2003 Page 3 of 9 Page 1 ❑ New 1. A Preliminary and Final Drainage Report meeting the requirements of the City of Greeley's SDDC manual will be required before grading and building permits can be approved. Detention of the 100 year developed storm event and discharge at the 5 year undeveloped flow rate will be required. C.Civil Drawings Page 1 ❑ New 1.All topographic mapping is to be based on NGVD 29 survey datum. The City of Greeley will not accept any other datum nor will an adjustment from some other datum to NGVD 29 be acceptable. Old City of Greeley benchmark datum is not acceptable. All contour mapping and construction details must be on NGVD 29 datum. 2. Drainage will require a Site Plan that includes contours and drainage flow arrows showing where the site will route stormwater flow. 3.An Erosion Control Plan will be required. Include all pertinent details and notes as required per the SDDC Manual section 13. 4. Callout, dimension, and detail a wheel washout facility that will be utilized until the street improvements are completed. 5. Callout, dimension, and detail a concrete truck washout basin that will be utilized to wash out concrete trucks until all concrete work is finished for the development. D.Landscape Page 1 ❑ New 1. No more than 1-2 deciduous, small leaf, maintainable to a single stem, and not inherent to suckering per 4500 square foot of pond bottom will be allowed. These trees shall be planted as far away from the outlet structure as possible to prevent plugging the outlet and WQCV holes. 2. No large evergreen trees shall be allowed in the pond that will affect the volume of the pond. Monday,March 17,2003 Page 4 of 9 Project Review Comments City of Greeley Project Name Weld County Food Bank (537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # Reviewed By Derek Glosson Department PW-oeslign/Review Date 3/17/2003 General Page ❑ New When submitting for annexation, all requirements set forth in Section 18.26.030 of the City of Greeley Development Code should be met. ❑ New All improvements should be constructed per City of Greeley standards. ❑ New Permit needed from City of Greeley Public Works Department for construction in public ROW or easement. ❑ New Any curb, gutter or sidewalk that is damaged during construction will need to be replaced. /1 rsn�Ta7•..?+MYi,rr»tak±mlrit�.:ar..c.:,s;?7iltbcsww�umRvahzrkrx.:r»:wwowxixM?ytuwo:..uuu.rnaxr5b. -u:r>:.+:wMw.:anr:::.e«w.raw+.ar•n.,.ua:::rMx«..::.:;,m..:o....ew:ray...»m:::....mxwe:::w.u.....».:ne..,:_:-.».a...-..u».....,......-....n.rn. Monday,March 17,2003 Page 5of9 Project Review Comments City of \reek Project Name Weld County Food Bank(537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # 1 Reviewed By Fred Jones Department Public Works -Traffic Date 3/17/2003 General Page ❑ New No comments at this time. Monday,March 17,2003 Page 6 of 9 Project Review y,. i Comments Gee ty of Greeley Project Name Weld County Food Bank(537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # 1 Reviewed By Duane McDonald Department UCFRA Date 3/17/2003 General Page ❑ Art 1. It appears the structure will need to be protected with an automatic fire sprinkler system. This is due to access problems around the rear of the structure. 2. Fire hydrants required to produce fire flow required by 1997 UFC. ?5411�C!SY:f9:lJ:i25itt07Q�i•!9........,kk...!':•;MK:f......:Rri�sY�1YMYifM:YeCiHHH�..i'.'l.4iY!W. ............:X'.:�T:�i......:n:......h::::l:a.•,.n•-rto.:••:•ae::.....w��.�xt•: •.:.: ws...n.rnw•n.•n.<•..rauws....Mn.ar.�<r.w.e........�.... Monday,March 17,2003 Page 7 of 9 Project Review Comments City of Greeley Project Name Weld County Food Bank (537) Location 1108 H Street Submittal Date 3/3/2003 Submittal # 1 Reviewed By Michael Whitley Department Planning Date 3/17/2003 Page O The applicable flood plan regulations must be complied with. O The parking requirements will be as follows: 2 parking spaces per 3 employees/volunteers in the warehouse 1 parking space per 300 square feet of office 1 parking space per 250 square feet of area available to the public. Please provide information as to how the proposed plan meets these standards in your narrative. O Is there any exterior lighting or parking lot lighting proposed? If so, and lighting plan showing architectural detail and a photometric plan will be required. ❑ The Architectural Review Standards found in Section 18.40.090 will apply to this building. The building needs to have architectural articulation as per Section 18.40.090.A.2. 20% of all wall surfaces need to have openings (windows, doors, etc.). Please identify the exterior building materials on the elevations. The Development Code requires that new buildings meet 4 of the 5 groups of standards found in Section 18.40.090.A.10. With the level of detail provided, the proposed building does not appear to meet any of the 5 groups. ❑ The property is in a High Impact area according to the City of Greeley's Areas of Ecological Significance Map. A Biologist's Report should be submitted prior to the issuance of a building permit. ❑ The setback needs to be 25 feet adjacent to a public street. Monday,March 17,2003 Page 8 of 9 ❑ An I-M zoning district is required to allow outdoor storage. Outdoor storage must comply with the design review criteria found in Section 18.46.170 of the Development Code. ❑ The king lot needs to be screened from the right-of-way as per Section 18.44.070 of the Development Code. A landscaped island needs to be added to the parking lot on the east side of the building. More detail (exact species, size, soil amendments, method of irrigation, etc.)is needed on the landscape plan. O The building elevations need to be to scale, dimensioned, and they need to note building materials. ❑ The Utility and Service Standards found in Section 18.40.070 must be adhered to. Please indicate how the utilities will be screened. Trash receptacle enclosure details are also required. ❑ Please provide information as to the square footage and percent of the site covered in: 1. buildings, 2. parking and maneuvering, 3. other hard surfaces, and 4. landscaping. ❑ Tire stops will be required for parking spaces adjacent to sidewalks and landscaped areas. ❑ An access easement will be required on the property to the east. That access easement should at least be as wide as the necessary backing and maneuvering area required for trucks using the loading docks. O Please refer to the attached Non-Residential Site Plan Check List when resubmitting. Larger plans will be easier to review. Because the plan is so small and does not appear to be to scale, I could not measure distances on the plan accurately. ❑ The attached pages from the Development Code explain the submittal requirements for the establishment of zoning. ❑ Please refer to the attached annexation packet for complete annexation application requirements. ❑ Please show the public sidewalk on the site plan. r Monday,March 17,2003 Page 9 of 9 .:r ,, MEMO y Community Development Planning Division City of Greeley Date: April 4, 2003 To: Michael Whitley, Planner II From: Karen Scopel, Natural Resources Planner Subject: Weld Food Bank Project The proposed Weld Food Bank project is located within a moderate impact zone as shown on the Areas of Ecological Significance map. However, due to the exact location of the site, I have determined that a Biologist's Report will not be needed as I see no further impacts on the area than currently exist. If you need further information please let me know. Non-Residential Site Plan Check List City of Greeley Planning Division requirements for non-residential building permit review: Narrative describing proposal (i.e. location, address, zone district, use, square footage of each building, floor or unit, number of units, number of parking spaces, architectural details, landscaping, square footage of lot, square footage of open space, contact person with telephone and fax numbers). Site Plan demonstrating: • title, north arrow, scale, property address • property lines with dimensions • adjacent right of ways • building(s) foot print(s) • distance between property lines and all structures • easements with dimensions • utilities (existing and proposed) • access points • paved parking(with dimensions of typical spaces and accessible parking spaces and aisle widths) and bicycle parking • existing and proposed sidewalks, curbs and tire stops • lighting(location and total height of poles or wall packs) • landscape areas • open spaces areas • drainage detention area(s) • fences and walls • signs (locations and dimensions) including traffic control and directional signs • fire hydrant locations • trash receptacles with enclosures detail • recreational amenities Building Elevation Plans demonstrating all sides of building and identifying the following: • title, scale, direction • building height(s) • siding materials • roofing materials • roof pitch • colors • doors, windows, and other architectural details • exterior stairs and balconies Landscape Plan demonstrating: • title, north arrow, scale, property address • basic improvement as shown on the site plan • location of plants and materials including ground cover • quantity • size • species type • method of irrigation Lighting Plan (Photometric demonstrating foot candles) ************************************************************************** The following is a reference guide to the City of Greeley Development Code non-residential development standards. This list is not intended to be totally comprehensive but is designed as a general list of code sections containing the major standards applicable to non-residential developments. Specific site conditions may require additional code sections to apply to the proposal. 18.38 Zoning District Development Standards 18.38.020 General Provisions 18.38.080 C-L, C-H Commercial Districts 18.38.090 I-L, I-M & I-H Industrial Districts 18.40 General Performance Standards 18.40.050 Vehicular Access and Circulation Standards 18.40.070 Utility and Service Standards 18.40.080 Environmental Standards 18.40.090 Site and Building Design Standards 18.40.100 Lighting Standards 18.42 Off-Street Parking and Loading Standards 18.42.040 General Provisions 18.42.050 Off-Street Parking Regulations 18.42.060 Parking for the Disabled 18.42.070 Bicycle Parking 18.42.080 Parking Space Dimensions 18.44 Landscaping and Buffering Standards 18.44.040 General Provisions 18.44.050 Landscape Standards 18.44.060 Buffer Yard and Screening Standards 18.44.070 Parking Lot Landscaping Standards 18.44.080 Perimeter Treatment 18.44.090 Fences, Wall and Hedges 18.46 Design Review Performance Standards 18.46.040 Infill Design Standards (Infill Areas Only) See Building Inspections for the number and type of plans required for each department (i.e drainage reports/plans or Traffic Impact Study for Public Works). S:\CD\Appl ication.forms\Non-ResSite.check.wpd Chapter 18.40 -General Performance Standards 18.40.060 2. Sidewalks or pedestrian pathways shall be provided on-site connecting the site and public sidewalks, all principal buildings on the site, parking lots and principal buildings on the site, and where logical connections to offsite locations can be made as identified in the City's pedestrian and bicycle route maps in the Transportation Plan. In no event is placement of a sidewalk or pedestrian pathway intended to displace existing landscaped areas or to duplicate existing pedestrian routes. 3. Where it is necessary for the primary pedestrian route to cross internal roadways, the pedestrian crossing shall be designed to emphasize and prioritize pedestrian access and safety. Such crossings shall be identified using pavement treatments, signals, lighting, traffic-calming techniques, median-refuge areas, and/or landscaping along with signs and , /// striping. 4. A system of pathways shall be provided for the use of bicyclists to use throughout and to and from • the site. Off-street routes may be combined with pedestrian VICH sidewalks or pathways and where combined shall be a minimum of eight feet (8') wide to accommodate the amount of pedestrian and bicycle traffic volumes expected to use the sidewalks or pathways. 18.40.070 UTILITY AND SERVICE STANDARDS A. The following standards are intended to ensure the appropriate location and design of all utility facilities greater than three feet (3) high and/or at least ten (10) square feet in size, which are visible from the adjacent public right-of-way or adjacent property: 1 . Where required, utilities and services shall be of such size, proportion, and location to effectively serve their intended purposes. 2. All utilities, including telephone, cable television, and electrical systems shall be installed underground, unless exceptional circumstances prevent underground installation. 3. Appurtenances to utility systems which require above-ground installation, including utility pedestal boxes and utility meters, or ground-mounted mechanical equipment, such as HVAC equipment, shall be located away from the view of adjacent public rights-of-way, where practical, and, where City of Greeley Development Code Chapter 18.40-Page 6 January 1, 2003 �• Chapter 18.40 - General Performance Standards 18.40.070 visible from the public right-of-way or adjacent property, shall be buffered by a fence, wall, or landscaping, or a combination of such methods, and be readily accessible for service and maintenance purposes. Where a wall is used for screening purposes, it shall be designed to be compatible with the related principal structures or buildings on the site, w►.u.4casgN including the use of the same, similar, or U compatible colors and materials as used on the aouitwicr41 r sa. related principal structures or buildings. Such screen walls shall not be continued for longer 7 than fifty feet (50') without variation or creating s � rn the appearance of variation by using changes in i, s height, different material combinations, or textures, offset angles, or articulation along the cEwvr_c nruw� top and/or bottom of the wall. Where posts or columns are used to create variation, they shall protrude a minimum of six inches(b")from the adjacent plane of the wall along the street side. When walls are articulated, consideration should be given to the maintenance of landscaping on the street side of the wall. 4. All rooftop mechanical equipment and elements, including bracing structures for such equipment, shall be concealed from the view from adjacent public rights-of-way or adjacent properties. Where not practical to screen due to grade changes, such as an elevated overpass, rooftop mechanical equipment shall be painted to match the roof or building, or match the sky if the equipment is silhouetted. Screen walls may also be required for concealment, depending on the nature of the adjacent roadway or development. Single-family and two-family dwellings and industrial areas where the rooftop mechanical equipment is not visible from adjacent properties zoned other than I-M (Industrial Medium Intensity) or I-H (Industrial High Intensity) or visible from an adjacent public right-of-way shall be exempt from this provision. Grain elevators shall also be exempt from any screening requirements for rooftop mechanical equipment. The Community Development Director may waive rooftop mechanical equipment screening requirements for property in commercial zones as long as there is no view of the equipment from an adjacent property, nor is the equipment visible from the adjacent public right-of-way or to the public using the subject property, such as from a parking area on-site. 5. A trash receptacle, sufficient in size to landrupinI Enclosure saw accommodate the trash generated by the use(s) shall be provided on-site in a location which does not impede • d pedestrian or vehicular circulation or �' !� :� �a r l r: clear-vision-zone requirements, is not located in front or side setbacks, or visibl `,� . .• •`• sar-amtrrs from streets, excluding alleys, and which i natty doors accessible to refuse trucks. Such Concrbtn Fad City of Greeley Development Code Chapter 18.40-Page 7 January 1, 2003 n Chapter 18.40 - General Performance Standards 18.40.070 receptacle or a grouping of receptacles which occupies an area in excess of fifteen (15) square feet in the aggregate shall be enclosed on at least three (3) sides by a solid wall or fence six feet (6') in height and by a solid gate no less than five feet (5') in height on the fourth side. The wall or fence and the gate shall be architecturally compatible with the building(s) which it accompanies using related or similar materials and colors. All trash receptacles shall have lids which shall be kept closed. 18.40.080 ENVIRONMENTAL STANDARDS A. The following standards are intended to provide uniform environmental performance standards for environmental conditions in recognition that the quality of life in a community is enhanced when free from the nuisances created by these environmental conditions. Excessive exposure to such environmental conditions can adversely affect the health, safety, and welfare of the citizens of Greeley, and the establishment and enforcement of reasonable standards is an effective way to regulate such conditions. 1 . Air quality. All land uses shall conform to all applicable local, state, and federal air quality standards, including, but not limited to, dust, smoke, fumes, or gases which are noxious, toxic, or corrosive, and suspended solid or liquid particles. 2. Water aualitv. All land uses shall conform to all applicable local, state, and federal water-quality standards, including, but not limited to, erosion and sedimentation, storm drainage and runoff control, solid wastes, and hazardous substances. 3. Glare and heat. All land uses shall be prohibited for emitting heat or heated air which may cause distress, discomfort, or injury, or direct glare, including, but not limited to, sources generated by floodlights, spotlights, searchlights, combustion, or welding perceptible beyond the property line of origin without the use of instruments. (See also Section 18.40.110, Lighting.) 4. Noise. No person shall cause or allow the emission of noise from any single source which is in excess of the limits described in Chapter 9.28. 5. Vibration. There shall be no inherent and recurring generated earth vibrations or concussions perceptible without instruments at any point along the property line. Ground vibrations between the hours of 7:00 a.m. and 7:00 p.m. caused by motor vehicles, trains, aircraft, construction activity, or oil and gas activity shall be exempt from these standards. 6. Odors. No person shall cause or allow the emission of odorous air contaminants from any single source such as to result in detectable odors which are measured in excess of the limits described in Chapter 9.52. City of Greeley Development Code Chapter 18.40- Page 8 January 1,2003 Chapter 18.40 -General Performance Standards 18.40.080 7. Hazardous Materials: a. The use or storage of hazardous materials shall comply with all applicable local, state, and federal standards. b. If the proposed use includes the use or storage of hazardous materials, adequate precautions to protect against hazardous materials release shall be provided. c. Flammable and combustible liquids and gases shall be stored in accordance with the Fire Code. 8. Storage and disposal of waste. All land uses shall comply with all applicable local, state, and federal standards regarding storage and disposal of wastes. 9. Electromaanetic interference. No land use, activity, or process shall be conducted which produces electric or magnetic fields which adversely affect public health, safety, and welfare, including, but not limited to, interference with normal telephone, radio, or television reception off the premises where the activity is conducted. 10. Radiation. Radioactive material and/or emissions shall comply with all applicable local, state, and federal standards. Further storage or use of such materials shall be subject to approval by the Fire Authority. 11. Ecological sianificance. Conformance with the provisions of Chapter 18.48, Areas of Ecological Significance shall be required. 18.40.090 ARCHITECTURAL REVIEW STANDARDS A. The following architectural review standards are intended to improve the appearance of new buildings and structures through the use of creative design and to ensure that new buildings and structures are compatible with existing buildings and structures, as well as the context of the surrounding area. These standards shall apply to all triplex, fourplex, town home, multifamily, commercial, and institutional land uses in new developments, in addition to all other applicable provisions of Chapter 18.40. These standards shall also apply to the C-H (Commercial-High Intensity) and I-L (Industrial-Low Intensity) districts, except when waived by the Planning Commission. Such waivers shall be considered when the proposed building or structure is located internal to the site and not visible from an adjacent public right-of-way, is not adjacent to residential uses or zones where residential uses are permitted, and where the proposed architecture better fits with the surrounding area. These standards shall also apply to the I-M (Industrial-Medium Intensity) and I-H (Industrial-High Intensity) districts, except when waived by the Community Development Director, where the sides of a building or structure are not visible from the adjacent public right-of-way, nor visible from adjacent properties zoned other than I-M or I-H. Properties adjacent to CD- (Conservation District-) and H-A- (Holding-Agriculture-,) zoned properties are required to comply with these standards. For the r City of Greeley Development Code Chapter 18.40- Page 9 January 1,2003 Chapter 18.40 - General Performance Standards 18.40.090 purposes of this section, a side of a building or structure facing a public right-of-way shall be considered visible regardless of landscaping which may be located between the differing land uses or the right-of-way. 1. Building design shall contribute to the special or unique characteristics of an area and/or development through the use of predominant building massing and scale, building materials, architectural elements, and color pallette. Where there is no established or consistent neighborhood or area character or unifying theme, or where the existing character is not desirable to continue because it does not reflect a design theme consistent with the architectural standards as described in this chapter,the proposed development shall be designed to establish an attractive image and set a standard of quality for future developments and buildings within the area to follow. Greater attention to design shall be required in areas of high visibility, such as along community entryways and arterial and major collector roadways and in special character districts. Design of such areas must be consistent with adopted entryway and special area plans on file in the Community Development Department. Where a portion of a building is visible from the adjacent public right-of-way or an adjacent property, the architectural treatment shall be extended around the visible portions of the building to the extent that an architecturally finished appearance consistent with these standards is achieved. 2. The design of buildings shall avoid the appearance of a single, large, dominant building mass by using design techniques that include stepping back portions of the building facade, breaking up the mass into smaller elements, and/or using material changes. For building facades or walls which face public rights-of-way or adjacent properties and are in excess of one hundred feet (100') in length, as measured horizontally, a minimum of twenty percent (20%) of the length of the facade or wall shall project or recess at a minimum depth equal to three percent (3%) of the length of the facade or wall, or screening of at least fifty percent (50%) of the wall area may be provided as an alternative using any required buffering to meet this provision. 3. Developments with multiple buildings shall include predominant characteristics in each building so that the buildings within the development appear to be part of a cohesive, planned area, yet are not monotonous in design. Predominant characteristics may include use of the same or similar architectural style, materials, and colors. If dissimilar materials are proposed, then an evaluation shall be made to determine if site design, building scale, form, color, landscaping, etc., can be used to make the building compatible with its surroundings. 4. Wall mass shall be proportionate to the area the wall is intended to carry or occupy and shall be designed to avoid blank wall expanses. Openings, such as windows and doorways, shall create a sense of continuity and rhythm to a building design. Openings or architectural elements simulating fenestration-like features shall occupy at least twenty percent(20%) of the wall surface area of the first floor of the front facade and walls adjacent to public rights-of-way or visible from adjacent properties. City of Greeley Development Code Chapter 18.40- Page 10 January 1,2003 Chapter 18.40 - General Performance Standards 18.40.090 5. Primary public building entrances shall be clearly defined and recessed or projected or framed by elements such as awnings, arcades, or porticos. 6. Colors shall be used to blend buildings into an area and to unify elements of a development. Color should be drawn from the surrounding area and, if in a newly developing area, shall be selected to establish an attractive image and set a standard of quality for future developments and buildings within the area. Monotonous or monochromatic color palettes are strongly discouraged. Accent colors, used to call attention to a particular feature or portion of a building or to form a particular pattern, shall be compatible with predominant building base colors and may be incorporated using such elements as shutters, window mullions, building trim, and awnings. Accent colors shall cover no more than five percent (5%) of a building facade. Changes in the building base color should occur at a change of building plane. 7. Where the proposed architecture of a building or structure is the result of a franchise style, prototypical or franchise architectural design, including materials and color, shall be modified if necessary to meet these architectural review standards and set a standard or contribute to a high level of quality for future developments and buildings within the area. Illumination outlining a building or translucent awnings intended to function as signage shall not be permitted as part of a building design. 8. Reflective materials,such as reflective, mirrored, tinted, or frosted glass with an opacity of less than twenty percent (20%), as determined by the glass manufacturer, shall not be permitted, except on the upper floors of commercial structures and industrial employment campuses, and where the area is not intended as an area of pedestrian activity. Where reflective materials are proposed, the City may require the applicant to provide information that can be used to evaluate whether the use of such materials will create a safety hazard for drivers on area streets. 9. Required primary exterior building materials shall be brick, stone, integrally tinted and textured masonry block, precast concrete, wood, natural and synthetic stone, stucco and synthetic stucco, and glazing. A minimum of seventy-five percent (75%) of all exterior building walls shall be covered with required primary building materials or other materials approved by the Community Development Director or designee. Metal shall not be used as a primary exterior building material except in the I-M (Industrial-Medium Intensity) and I-H (Industrial-High Intensity) zones. Where such buildings in the I-M and I-H zones are visible from an adjacent collector, arterial, or parkway arterial, or are visible from an adjacent nonindustrial use or zone, at least seventy-five percent (75%) of the exterior of the building walls that are visible from the public right-of-way or adjacent use or zone shall be covered with other acceptable primary exterior building materials and shall have the applicable buffer yard installed between the building and public rights-of-way. Metal, including corrugated metal, may be used as an accent material on the primary facade of any commercial or industrial building as long as the amount used does not exceed twenty percent (20%) of the area of the primary facade, exclusive of the roof, and it is painted to match or City of Greeley Development Code Chapter 18.40- Page 11 January 1, 2003 Chapter 18.40 - General Performance Standards 18.40.090 complement the building color scheme. Otherwise, buildings of non-architectural metals shall be covered with a veneer that is compatible with other area building exterior finishes. Architectural metals, such as bronze, brass, copper, and wrought iron, may be used on the primary facade of any building and may exceed twenty percent(20%) of the area of the primary facade. Other materials may be evaluated for use as primary or accent materials by the Community Development Director or designee to determine whether the proposed materials are equal or superior to the required primary building materials and permissible for use. Changes in materials should occur at a change of building plane. 10. All buildings shall be designed and maintained using the following building elements, with a minimum of one (1) selected from four (4) of the five (5) groupings below: a. Group 1 - Exterior Wall Articulation: (1) Changes in building plane or articulation (recesses, projections) spaced proportionately around the building. Exterior walls with recesses and projections, as defined in Section 18.40.090.A.4; or (2) Building bays created by columns, ribs, pilasters, or piers, or an equivalent element that divides a wall into smaller proportions or segments, with elements being at least one foot (1') in width and spaced at intervals of no more than thirty percent (30%) of the exterior building walls; or (3) Some other architectural feature or treatment which breaks up the exterior horizontal and vertical mass of the building. b. Group 2 - Roof Articulation: (1) Changes in roof lines, including the use of stepped cornice parapets, a combination of flat and sloped roofs, or pitched roofs with at least two (2) roof line elevation changes; or (2) Some other architectural feature or treatment which breaks up the exterior horizontal and vertical mass of the building. c. Group 3 - Building Openings,Walkways, and Entrances: (1) Canopies or awnings over at least thirty percent (30%) of the openings of the building; or (2) Covered walkways, porticos, and/or arcades covering at least thirty percent (30%) of the horizontal length of the front facade; or City of Greeley Development Code Chapter 18.40- Page 12 January 1, 2003 Chapter 18.40 - General Performance Standards 18.40.090 (3) Trim boards or lintels, ledges, or similar architectural accent features between two inches and six inches (2"-6") in width around all windows and doorways; or (4) Raised cornice parapets over entries; or (5) Some other architectural feature or treatment which adds definition to the building openings, walkways, or entrances. d. Group 4 - Building Materials: (1) At least two (2) kinds of materials distinctively different in texture or masonry pattern, with each of the required materials covering at least twenty-five percent (25%) of the exterior walls of the building (see also Section 18.40.090.A.12); or (2) A single material as long as design treatment such as different roof lines, number of stories, window and door style and placement, and/or garage placement, are used to create an interesting and varied exterior; or (3) Brick or stone covering at least fifty percent (50%) of the exterior walls of the building. e. Group 5 - Other Architectural Definition: (1) Overhanging eaves extending at least eighteen inches (18") past the supporting walls, or with flat roofs, cornice, parapets, or capstone finish; or (2) Ornamental lighting fixtures (excluding neon) used for all exterior building lighting; or (3) An additional feature which adds architectural definition to the building. 1 1 . Alternate designs to meet the intent of this section may be reviewed and considered under the provisions for alternative compliance as provided in Section 18.38.140. 18.40.100 SITE AND BUILDING DESIGN STANDARDS A. The following standards are intended to ensure that all elements of a site, including buildings, structures, and parking areas, are located on the site in such a way as to provide a cohesive and well-designed site that is compatible with the surrounding neighborhood: es- City of Greeley Development Code Chapter 18.40- Page 13 January 1,2003 Chapter 18.40 -General Performance Standards 18.40.100 1. All proposed buildings, structures, and parking areas shall be arranged on the site to be consistent with the character of the surrounding area, including maintaining similar building scale, orientation, and setbacks. 2. The site shall be designed to minimize the disturbance of topography, water bodies, and other natural features on the site. 3. Site design and subsequent development shall ensure that precautions have been taken to minimize hazards from irrigation canals, streams, or other water bodies on the site. 4. Buildings shall generally be oriented toward the street or public spaces, while service and loading areas on the site shall be located away from the view from public rights-of-way and adjacent residences. Loading and parking areas L. shall be designed to be sympathetic to or ••- _ It - 1 improve upon the design of the conforming uses of the surrounding area, - providing good transitions between service areas and other areas on-site. - -- --1 5. If the back or sides of buildings are oriented toward public streets or rights-of-way, building details, landscaping, berming, or a combination thereof shall be used to create a level of visual interest which is equal to that of the building front. 6. Buildings and parking areas shall be arranged on the site to maximize the opportunity for privacy by the residents of the development and those residents adjacent to the site and to minimize on-site conflicts between pedestrians and vehicles. 7. Where practicable, open space and/or recreational amenities shall be centrally located in proximity and accessible to those residents or occupants which they are intended to serve. 8. Additions shall be designed to be compatible with the principal building by using similar form and scale, architectural style, and colors. a. Additions to Residences: AV., (1) The maximum height of an r addition shall be limited to one ' hundred fifty percent (150%) of the height of the existing principal structures on the block City of Greeley Development Code Chapter 18.40-Page 14 January 1,2003 Chapter 18.40 - General Performance Standards 18.40.100 face. If one (1) or more of the principal structures on the block face is greater than thirty feet (30') in height, the maximum height of an addition shall be limited to the average height of the existing principal structures on the block face. (2) The maximum length and width of an addition shall be limited to one hundred fifty percent (150%) of the average length and width of perimeter walls of the existing principal structures on the block face. If the subject block face is vacant, or if the street separating two (2) block faces which are opposite from one another is a local street or minor collector, the block face on the opposite side of the street shall also be used to determine average height and wall length of an addition. Such additions and the point of attachment thereof shall constitute a minimum of twenty percent (20%) of the circumference of the exterior walls of the addition. b. Additions to Commercial and Industrial Buildings: (1) Additions to commercial and industrial buildings shall be limited to the maximum height permitted in the particular zoning district and shall not be required to have a minimum point of attachment. 9. Accessory buildings and structures which require a building permit shall be designed to be compatible with principal buildings and structures by using similar form and scale, massing, architectural style, materials, and colors. Accessory buildings and structures shall not exceed the height of the principal building or structure and sixty percent(60%) of the footprint of the principal building or structure on the site, including attached garage area, except as provided in Section 18.52.030.A.1. 10. If the site contains a locally designated historic landmark, the site and building design shall provide for the protection of the historical and architectural value of the landmark. The site and building design for locally designated landmarks shall also be subject to the review and require approval of the designating agency. 1 1 . If the site is found to contain cultural or archaeological resources, including, but not limited to, artifacts of human, animal, or plant activity, such resources shall be preserved to the greatest extent practicable, as determined by the Colorado Historical Society, and the proposed development shall be designed around such resources so they are not damaged before or during construction. 12. A neighborhood identity feature shall be provided within all single-family and two- family residential or mixed-use developments, as shown in the chart in Subsection a. (below) as a place for gathering, recreation, or a design feature or features intended to create a unique character or sense of identity. Identity features may include a pocket park, trail system, pedestrian plaza or courtyard, community building or garden, artwork (such as a sculpture), water feature, fountain, playground, or City of Greeley Development Code Chapter 18.40-Page 15 January 1,2003 Chapter 18.40 -General Performance Standards 18.40.110 18.40.110 LIGHTING STANDARDS A. The following standards are intended to ensure that the design and placement of exterior lighting provides sufficient illumination for security purposes while not interfering with the safe movement of vehicles on public streets nor negatively affecting adjacent properties and land uses while providing adequate on-site lighting. These standards shall not apply to lighting for public streets. 1. No lighting shall be used in any way which could interfere directly or indirectly with the safe movement of vehicles on public streets, including: a. Any fixed lighting that is not designed for street illumination that produces light which could interfere with the operation of a vehicle. b. Any lighting which could be confused with any type of traffic-control device, emergency, or warning signals. c. Any lighting that blinks, flashes,flickers, or changes intensity, with the exception of temporary holiday displays. 2. Exterior lighting to meet function and security needs for the development shall be provided with no light spillage or glare visible at or beyond the property line of the development. Lighting shall be provided at sidewalks or pathways, common areas or facilities, primary building entrances, and in parking areas. 3. Freestanding light fixtures shall not exceed twenty t.r - feet (20') in height within fifty feet (50') of any residential zoning district, except as provided in Section 18.40.110.A.4. In all other locations freestanding light fixtures shall not exceed thirty feet (30') or the height of the principal building, ifjilt one exists, whichever is less. The style and materials of light standards and fixtures shall be d , compatible with the architectural character and materials of buildings on the site. For the purposes of this section, the height of the freestanding light fixtures shall be determined by measuring from the adjacent grade at the base of the support to the top of the light fixture. 4. Building-mounted light fixtures shall not be attached to a roof, and in no event shall the light fixture be mounted at a height exceeding thirty feet (30') above grade as measured at the base of the subject building. The use of lighting fixtures that are architecturally compatible with the related building is encouraged over the use of wall-pack lighting fixtures. City of Greeley Development Code Chapter 18.40- Page 25 January 1, 2003 Chapter 18.40 - General Performance Standards 18.40.110 5. All lights shall be directed downward, and the light source shall be shielded so that it will not be visible from any adjacent property, except for accent and flagpole lighting which shall be permitted to be directed upward as long as the light source is shielded and not visible from any adjacent property. Fixtures installed under canopies, awnings, overhangs, and the like shall be fully recessed. 6. The following chart lists maximum lighting levels for outdoor areas and facilities. These lighting levels are average-maintained horizontal levels and shall be measured using a calibrated, color-and-cosine-corrected portable light meter. The light meter shall be taken at a level position not more than six inches (6") above the ground with the subject light sources on. Lighting shall be measured as used on the site with no artificial manipulation occurring. MA 77D4001”E041tin(loot candJes)« Residential Commercial &' Area Zones Industrial Zones Building Exterior 0.5 1 .0 - 5.0 Walks, Pathways 0.5 1 .0 Parking Lots 1 .0 2.0 Street or Driveway Lighting 0.6 1.2 (internal to site) Loading Docks N/A 20.0 Auto Sales (outdoor display) N/A 30.0 Average; 60.0 Spot Location 'Information gathered from Illuminating Engineering Society(IES) Lighting Handbook. One (1)foot- candle is equal to one (1) lumen uniformly distributed over an area of one(1)square foot. 7. No activity shall be conducted within five hundred feet (500') of a residential zone which creates glare exceeding 0.5 foot-candle at the source's property line, except for parking lots, neighborhood recreation and service facilities, and streets, which may be illuminated at levels up to 1 .0 foot-candle. 8. All parking-lot lighting fixtures and exterior building floodlights, except those required for security purposes, shall be extinguished within one (1) hour after the end of business hours and remain extinguished until one (1) hour prior to the beginning of business hours. If a portion of a parking lot is offered for use after dark, only that portion shall be lighted. 9. Lighting within parking structures shall be designed to provide safety and security and shall be integrated into the architectural character of the structure. City of Greeley Development Code Chapter 18.40-Page 26 January 1,2003 Chapter 18.40 - General Performance Standards 18.40.120 10. The use of low-pressure sodium light fixtures shall be prohibited in the CHI/. 1 1 . In addition to all other standards herein, the following standards shall apply to the lighting of all outdoor recreational facilities, except baseball, softball, soccer, volleyball, or football fields; driving ranges; outdoor arenas; and amphitheaters. a. All lighting or illumination units or sources shall be hooded or shielded and directed downward so that they are not visible from any adjacent lot or property. b. Lights or illuminating units shall not allow light either directly or through a reflecting device to spill upon any adjacent real property. 12. In addition to all other standards herein, the following standards shall apply to baseball, softball, soccer, volleyball, or football fields; driving ranges; or other field recreation facilities: a. The height of any light fixture or illumination source shall not exceed ninety feet (90') in height. b. Individual lighting of one hundred fifty (150) watts or greater shall not be used after 11 :00 p.m. or within one (1) hour after the event,whichever is later. Exceptions to this section may be granted by the Community Development Director. 18.40.120 ARCHITECTURAL REVIEW PROCESS A. Architectural Review Committee. The Architectural Review Committee shall consist of five (5) members appointed by the Planning Commission and serve pursuant to the provisions of Chapter 19-5 of the Greeley City Charter and perform the duties and functions prescribed in this Code. Committee members should have experience in and represent the areas of architecture, construction, engineering, landscape architecture, planning, urban design, real estate, or other related fields. Appointments to the Committee shall, to the extent feasible, include at least one (1) member representing the construction industry and at least one member representing the field of architecture. In addition, it is desirable to have one (1) committee member representing the general public. A member of a specific board or commission, such as the Downtown Development Authority (DDA) or Historic Preservation Commission, or a member of a character overlay district, such as the Mercado, may serve in an ex-officio capacity to assist the Architectural Review Committee on matters of interest to the group, board, or commission. B. The applicant for a land-use or development application may seek advice or consult with the Architectural Review Committee on matters pertaining to architectural design. City of Greeley Development Code Chapter 18.40- Page 27 January 1,2003 Chapter 18.44 - Landscaping and Buffering Standards 18.44.060 r• 4. The preservation of existing trees in buffer yards shall be allowed as a substitute for the required plant materials as provided for the in the Credit for Existing Trees table in Section 18.44.050.A.5.b. When existing trees are located in only a part of the buffer yard, the number of trees or shrubs required may be reduced in proportion to the percentage of the area of the buffer yard occupied by existing trees. 5. If a newly developing property is adjacent to a vacant property of a different zone, then, as a minimum standard, Buffer Yard Type A shall be required of the newly developing property until the adjacent property is developed, at which time the developer of the adjacent vacant property shall be responsible for providing any remaining portion of required buffer yard, based on the intensity levels of the land uses. Refer to Charts 1-3 for further information. 6. If a newly developing property is adjacent to a lot that is developed, that portion of the buffer yard which has not previously been provided on the developed lot shall be required of the newly developing property. 18.44.070 PARKING LOT LANDSCAPING STANDARDS A. When a parking lot which contains at least six (6) parking spaces in any zone district is located adjacent to a public right-of-way or a residential • use, screening at least three feet (3') high providing .t screening of at least sixty percent (60%) opacity • r."r;-. 1'7.1-P year-round for at least seventy-five percent (75%) of 'c t r the frontage shall be required between the parking �, 1D! z - or • lot and the right-of-way or residential use. Such }r ��- >i ah` screening shall be located on a setback a minimum of ten feet (10') in width and shall consist of landscape plantings, berming, fencing, walls, or a Screening to 60% Opacity combination thereof, and shall be subject to meeting all clear-vision provisions of Section 18.44.090.B. B. Parking lots containing at least six (6) parking spaces shall have landscaped islands within a minimum of five percent (5%) of the interior of the parking lot. Such landscaped islands shall contain a minimum of one (1) two-inch-caliper (2") deciduous shade tree. 1. For every sixteen hundred (1,600) square feet of parking area and access drives, one (1) two-inch-caliper (2") shade tree, or the equivalent from the following chart, shall be provided in and around the parking area. For example, a four-thousand- (4,000) square-foot parking area may use one (1) three-inch-caliper (3") shade tree. Alternatives may be made using two (2)two-and-one-half-inch-caliper (2'/2") shade trees, three (3) two-inch-caliper (2") shade trees, or three (3) one-and-one-half-inch- caliper (11/2") ornamental trees. Equivalents or substitutions that result in a fractional number shall be counted as one (1) additional tree. r City of Greeley Development Code Chapter 18.44 -Page 17 January 1,2003 Chapter 18.44 - Landscaping and Buffering Standards 18.44.070 =C EE �QUtvA1 1 OR ARKI ARE . . 2" Caliper Shade Tree 1,600 Sq. Ft. of Parking Area 21/2" Caliper Shade Tree 2,500 Sq. Ft. of Parking Area 3" Caliper Shade Tree 4,000 Sq. Ft. of Parking Area 1 '/2" Caliper Ornamental Tree 1,400 Sq. Ft. of Parking Area 6' Evergreen Tree for 50% of Required 2" Caliper Trees For the purposes of computing the total area of the interior of any parking lot, all areas within the perimeter of the parking lot shall be counted, including planting islands, curbed areas, corner areas, parking spaces, and all interior driveways and aisles, except those with no parking spaces located on either side. Landscaped areas situated outside of the parking lot may be counted toward meeting the interior landscaping requirement, if such areas provide shade in the parking lot and if approved by the City. C. Deciduous shade trees shall be provided within the interior of parking areas in landscaped islands a minimum of six feet (6') in width and nineteen feet (19') in length, or equal to the length of a parking stall if other than a standard stall dimension is used. The remaining area surrounding trees shall be landscaped with shrubs not to exceed three feet (3') in height and groundcover, or non-organic material, as long as the non-organic material does not exceed twenty-five percent (25%) of the total landscaped area. D. Landscaped areas within parking lot interiors shall be located in such a manner as to divide and break up the expanse of paving. There shall be no more than fifteen (15) parking spaces in a continuous row on one (1) side without being broken by a landscaped island. The Community Development Director may waive this requirement and permit a maximum number of twenty (20) continuous spaces if the alternative parking lot design 16.4024 facilitates the flow of traffic, takes into consideration the lot configuration, and otherwise meets the intent of these standards. Landscaped aisles which have parking on both — sides may be permitted as an alternative to individual landscaped islands as long as no more than fifty percent (50%) of the required islands and the equivalent area of said islands are incorporated into landscaping aisles. E. Landscaped areas shall be protected from vehicular encroachment by the use of wheel stops or curbing. Wheel stops shall be placed to prevent damage to any planting areas by vehicular overhang. City of Greeley Development Code Chapter 18.44 - Page 18 January 1,2003 Chapter 18.44 - Landscaping and Buffering Standards 18.44.080 18.44.080 PERIMETER TREATMENT A. Single-family, two-family, and mobile-home communities, town houses, multifamily dwelling units, and institutional uses shall be buffered from major collector or arterial streets using Buffer Yard Type B and shall be buffered from state or federal highways using Buffer Yard Type C or an equivalent option. B. The side or rear of commercial or industrial developments shall be buffered from the view of highways or major collector or arterial streets using Buffer Yard Type B or an equivalent option. C. A single fence or wall design used in perimeter treatment plans shall not be - - continued longer than fifty feet (50') without variation or creating the appearance of variation by using changes in height, 4 , different material combinations, offset '- • angles, articulation along the top and/or I.`c- • bottom of the fence, plant materials, and/or berms. Where posts or columns are used to create variation, they shall protrude a Perimeter Treatment (fence, columns, minimum of six inches (6") from the adjacent shrubs) plane of the fence along the street side. When fences are articulated, consideration should be given to the maintenance of landscaping on the street side of the fence. D. The design of a perimeter treatment plan shall give consideration to any existing perimeter treatments adjacent to the subject property and provide a design that ties in or is compatible with existing perimeter treatments. Perimeter treatment plans for community entryways as identified in the City's entryway master plan shall be designed to meet the established major collector or arterial entryway standards. E. A perimeter treatment shall not be required for individual single-family or two-family dwellings which are not part of a subdivision. F. Landscape materials installed for individual single-family or two-family dwellings or lots shall not be counted as part of a perimeter treatment plan. G. A mechanism for maintaining perimeter treatments shall be established by the developer and approved by the City. H. A required perimeter treatment shall be installed concurrent with other site infrastructure improvements, as per Section 18.04.1295, prior to building permit issuance. Fences and walls included as part of a perimeter treatment shall meet the provisions of Section 18.44.090, Fences, Walls, and Hedges. City of Greeley Development Code Chapter 18.44 -Page 19 January 1,2003 04/24/03 THU 13:49 FAX 970 350 9518 UCFRA FIRE PREVENTION 2001 • (jilt6 Weld County Referral ' March 20, 2003 C. COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Weld County Case Number USR-1424 Please Reply By April 18,2003 Planner Sheri Lockman Project Site Specific Development Plan and a Special Review Permit for a business permitted as a use by right or accessory use in the Commercial Zone District (Food Warehouse) in the A(Agricultural)Zone District. • Legal Lot 2 as shown on RS-1023; Re-subdivision of Union Colony Subdivision; being part of Section 27,T6N, R67W of the 6th P.M.,Weld County, Colorado. Location West of 11th Avenue and Southwest and adjacent to North 171h Avenue. Parcel Number 0803 31 401009 The application Is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services, If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) May 6, 2003 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan • We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. • Comments: ( AMY( mer ter" 640Dfrola Liaof„tl 4u, i'EY A aMCE `IF issues. Signature C 1/a. Date Agency (.ivro.J Gc4.wrAxe/at- cdc • +Weld County Planning Dept. +1555 N.17th Ave. Greeley,CO.90631 O(970)353-6100 ext3540 +(970)304-6498 fax i1 Kits Weld County Referral March 20, 2003 C. COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Weld County Case Number USR-1424 Please Reply By April 18, 2003 Planner Sheri Lockman Project Site Specific Development Plan and a Special Review Permit for a business permitted as a use by right or accessory use in the Commercial Zone District (Food Warehouse) in the A(Agricultural)Zone District. Legal Lot 2 as shown on RS-1023; Re-subdivision of Union Colony Subdivision; being part of Section 27, T6N, R67W of the 6th P.M., Weld County, Colorado. gg Location West of 11'h Avenue and Southwest and adjacent to North 17'h Avenue. Parcel Number 0803 31 401009 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) May 6, 2003 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ Ae have reviewed the request and find no conflicts with our interests. EV See attached letter. Comments: Signature l�S �? Date / rA A J Z I -2,,c7O3-2,,c7O3Agency (R 77' '^^�77 C9A /d w1y +Weld County Planning Dept. +1555 N. 17th Ave. Greeley,CO. 80631 +(970)353-6100 ext.3540 +(970)304-6498 fax ^Kit Lei DEPARTMENT OF BUILDING INSPECTION �-. Weld County Administrative Offices 1555 N. 17th Avenue, Greeley, CO WEBSITE: www.co.weld.co.us Phone (970) 353-6100, Ext. 3540 ' Fax (970) 304-6498 co COLORADO March 21, 2003 Weld County Site Specific Development Plan and Special Review Permit for a business permitted as a Use by Right or Accessory Use in the Commercial Zone District (Food Warehouse) in the A (Agricultural) Zone District. USR-1424 There are no active or historical building permits on record for this parcel. 1. A building permit shall be obtained prior to any construction. 2. A plan review is required. Plans shall bear the wet stamp of a Colorado registered architect or engineer. Two complete sets of plans are required when applying for the permit. 3. This building shall be accessible in accordance with Chapter 11 of the Uniform Building Code. 4. Buildings shall conform to the requirements of the various codes adopted at the time of permit application. Currently the following has been adopted by Weld County: 1997 Uniform Building Code; 1998 International Mechanical Code; 1997 International Plumbing Code; 2002 National Electrical Code and Chapter 29 of the Weld County Code. 5. Each building will require an engineered foundation based on a site-specific geotechnical report or an open hole inspection performed by a Colorado registered engineer. Engineered foundations shall be designed by a Colorado registered engineer. 6. Building height shall be limited to the maximum height allowed per UBC Table 5-B. Wall and opening protection and limitations shall be in accordance with UBC Table 5-A. Separation of buildings of mixed occupancy classifications shall be in accordance with UBC Table 3-B and Chapter 3. Setback and offset distances shall be determined by the Zoning Ordinance. 7. Building height shall be measured in accordance with the 1997 Uniform Building Code for the purpose of determining the maximum building size and height for various uses and types of construction and to determine compliance with the Bulk Requirements from Chapter 27 of the Weld County Code. Building height shall be measured in accordance with Chapter 23 of the Weld County Code in order to determine compliance with offset and setback requirements. Offset and setback requirements are measured to the farthest projection from the building. Service,Teamwork, Integrity,Quality Page 2 /''• 8. A Flood Hazard Development Permit shall be submitted for buildings constructed within the 100-year flood plain. Please contact me for any further information regarding this project. Sincerely, Jeff Reif Building Official Service,Teamwork, Integrity,Quality r RECEIVED *:4661\9MAR 2 4 2003 PUBLIC WOR(S DEPT Weld County Referral ipMarch 20, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Weld County Case Number USR-1424 Please Reply By April 18, 2003 Planner Sheri Lockman I Project Site Specific Development Plan and a Special Review Permit for a business permitted as a use by right or accessory use in the Commercial Zone District (Food Warehouse) in the A(Agricultural)Zone District. Legal Lot 2 as shown on RS-1023; Re-subdivision of Union Colony Subdivision; being part of Section 27, T6N, R67W of the 6th P.M.:Weld County, Colorado. Location West of 11th Avenue and Southwest and adjacent to North 17`" Avenue. Parcel Number 0803 31 401009 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Weld County Planning Commission Hearing (if applicable) May 6, 2003 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan O We have reviewed the request and find no conflicts with our interests. ASee attached letter. Comments: Signature 40J,,4La 4Sz UP/, /Date 76 C�� Agency \a, u th-tj 4Weld County Planning Dept. +1555 N. 17th Ave. Greeley,CO.80631 +(970)353-6100 ext.3540 +(970)304-6498 fax Weld County Planning Department GREELE'f OFFICE MEMORANDUM RECENED WI I C TO: Sheri Lockman, Planner II DATE: April 16, 2003 FROM: Donald Carroll, Engineering Administrator Lily/' • COLORADO SUBJECT: USR-1424, Weld County The Weld County Public Works Department has reviewed this proposal; this project falls primarily under the purview of the Use by Special Review Standards, Weld County Code, Chapter 23, Article II, Division 4, Section 23. Our comments and requirements are as follows: COMMENTS: Access: The existing access point will be shared with the Weld County Training Center for the proposed food warehouse from "H" Street. The secondary access identified in the plat drawing is also a shared access with the Weld Mining Division/temporary city storage facility. This access point and road is a part of the County's USR permitted haul route. 'The east access from the Weld County Training Center needs to be incorporated into the existing paved parking lot area. The north access point needs to be incorporated into the existing asphalt haul road with adequate turning radius. The access shall be paved from the entrance east of"H" Street. Circulation: With the layout of the proposed food warehouse, there is only one way that the large truck loading area can be utilized. The larger trucks will have to enter through the training center parking lot in order to back up to the loading dock. If the trucks enter from the northern access point with the configuration of the parking islands and stripped parking lot, turning radiuses throughout the parking lot would not accommodate direct access at this location. The other option is from the northern access point. The trucks would have to back 250 feet through a parking lot to the large truck loading area. This situation is not unusual, but not the . best situation. Storm Water Drainage: The historical flow patterns and run-off amounts will be maintained on site in such a manner that will reasonably preserve the natural character of the area and prevent property damage of the type generally attributed to the run-off rate and velocity increases, diversions, concentration and/or unplanned ponding of storm run-off. pc: USR-1424 M:\PLANNING\USR-1.doc MEMORANDUM TO: SHERRI LOCICMAN, PLANNING SERVICES - i FROM: CHARLOTTE DAVIS, ENVIRONMENTAL HEALTH v0 C. DATE:SUBJECT.04/1R1/O03-1424 WELD COUNTY FOOD BANK COLORADO CC. Environmental Health Services has reviewed this proposal for a Food Warehouse. We have no objections to the proposal, however, we do recommend that the following conditions be part of any approval: We recommend that the following requirements be incorporated into the permit as development standards: 1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. 2. No permanent disposal of wastes shall be permitted at this site. This is not meant to include those wastes specifically excluded from the definition of a solid waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended. 3. Waste materials shall be handled, stored, and disposed in a manner that controls fugitive dust, fugitive particulate emissions, blowing debris, and other potential nuisance conditions. 4. Fugitive dust and fugitive particulate emissions shall be controlled on this site. 5. This facility shall adhere to the maximum permissible noise levels allowed in the Commercial Zone as delineated in 25-12-103 C.R.S., as amended. 6. The facility shall utilize the existing municipal sewage treatment system. 7. The facility shall utilize the existing public water supply. 8. Adequate toilet facilities shall be provided for employees and patrons of the facility. 9. The applicant shall comply with Colorado Retail Food Establishment Rules and Regulations governing the regulation of food service establishments. 2 Hello