Loading...
HomeMy WebLinkAbout20040179.tiff REFERRAL LIST NAME: Loyd&Sheila Schlichenmayer CASE NUMBER: USR-1450 REFERRALS SENT: October 9, 2003 REFERRALS TO BE RECEIVED BY: November 7, 2003 COUNTY Ambulance Services TOWNS and CITIES _Attorney _Ault _X Health Department Brighton Extension Service Broomfield Emergency Management Office Dacono Sheriffs Office Eaton _X Public Works _X Erie Housing Authority Evans Airport Authority Firestone _X Building Inspection Fort Lupton _X Code Enforcement _X Frederick STATE Garden City _X Division of Water Resources Gilcrest Geological Survey Greeley Department of Health Grover Department of Transportation _Hudson Historical Society Johnstown Water Conservation Board Keenesburg Oil and Gas Conservation Commission Kersey Division of Wildlife: LaSalle Loveland Lochbuie Greeley Longmont Division of Minerals/Geology Mead FIRE DISTRICTS Milliken Ault F-1 New Raymer Berthoud F-2 Northglenn Briggsdale F-24 Nunn Brighton F-3 Pierce Eaton F-4 Platteville Fort Lupton F-5 Severance Galeton F-6 Thornton Hudson F-7 Windsor Johnstown F-8 La Salle F-9 _X Mountain View F-10 COUNTIES Milliken F-11 Adams Nunn F-12 _X Boulder Pawnee F-22 Larimer Platteville F-13 Platte Valley F-14 FEDERAL GOVERNMENT AGENCIES Poudre Valley F-15 US Army Corps of Engineers Raymer F-2 USDA-APHIS Veterinary Service Southeast Weld F-16 Federal Aviation Administration Windsor/Severance F-17 Federal Communication Commission Wiggins F-18 Union Colony F-20 SOIL CONSERVATION DISTRICTS Brighton OTHER Fort Collins alma" X School District RE-1J Greeley Ditch Company Longmont West Adams X_Boulder 2004-0179 K COMMISSION/BOARD MEMBER W _X Folsom rN•a eaaered 10/16/2003 08:50 3039262706 TOWN OF ERIE PAGE 01 • Weld County Referral October 9, 2003 C. COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Loyd & Sheila Case Number USR-1450 Schlichenmayer Please Reply By November 7, 2003 Planner Kim Ogle Project Site Specific Development Plan and Use by Special Review for a single fan-illy dwelling unit(other than those permitted under Section 23-3.20.A) in the A (Agricultural)Zone District. Legal Lot B of RE-761; part of the SW4 of Section 6,Ti N, R68W of the 6th P.M., Weld County, Colorado. Location 9/10 mile south of State Hwy 52; east of and adjacent to CR 1, Parcel Number 1467 06 300004 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. Weld County Planning Commission Hearing (if applicable) December 16, 2003 0, We have reviewed the request and find that it•doo ,'does not comply with our Comprehensive Plan O We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. /` �� �� � � �Comments: gnn .art/zioiQ! ./data.A/jai lAtg / Signature Date jp - /6„ Agency 7(641 J • +Weld County Planning Dept. +1555 N. 17th Ave. Greeley, CO. 80631 +(970)353-6100 ext.3540 +(970)304-6498 fax Lod_o , a ( it \ Weld County Referral • October 9, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Loyd & Sheila Case Number USR-1450 Schlichenmayer • Please Reply By November 7, 2003 Planner Kim Ogle Project Site Specific Development Plan and Use by Special Review for a single family dwelling unit (other than those permitted under Section 23-3-20.A) in the A (Agricultural)Zone District. Legal Lot B of RE-761; part of the SW4 of Section 6,TIN, R68W of the 6th P.M.,Weld County, Colorado. Location 9/10 mile south of State Hwy 52; east of and adjacent to CR 1. Parcel Number 1467 06 300004 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. Weld County Planning Commission Hearing (if applicable) December 16, 2003 ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. `$, See attached letter. Comments: ��((jv� '� ? denoR d, Signature —71' lTThey-\ Date t - j 7JO5 Agency EXHIBIT 4 Weld County Planning Dept. 41555 N. 17th Ave.Greeley, CO.80631 4(970)353-6100 ext.3540 ❖(970)304-6498 faxr , ritk; MEMORANDUM Wilke. COLORADO To: Kim Ogle, Planner October 13, 2003 From: Bethany Salzman, Zonlrfg Compliance Officer Subject: USR-1450 Referral Upon review of my computer and files, a combined Building and Zoning Violation (VI-0300134)was noted. The violation was initiated as a result of the conversion and utilization of a barn/garage as a dwelling unit without the necessary building and zoning permits. For more information, please speak with Peggy Gregory, Building Compliance Officer. cc: VI-0300134 Peggy Gregory, Building Compliance Officer SERVICE,TEAMWORK,INTEGRITY,QUALITY Aottitmtplo Memorandum TO: Kim Ogle, W.C. Planning CC DATE: October 14,2003 • COLORADO FROM: Trevor Jiricek, EH Services',,, CASE: USR-1450 APPLICANT: Loyd & Sheila Schlichenmayer Environmental Health Services has reviewed this proposal for a second single family residence on a single parcel. We offer the following comments: It is obvious from the submitted materials that extenuating circumstance led to the construction and development of the second home on this property. The approval and continued use of the second home does not meet Department policy in regard to density of septic systems per acreage (current policy recommends a minimum density of one septic system per two and one-half acres). If allowed, the density of septic systems would be one per one and one-half acres. Additionally, the well permit provided in the application materials indicates that the flow of the well serving the second home is 6 gpm. I discussed the well production with Loyd Schlichenmayer. Mr. Schlichenmayer indicated that they have installed a pressure tank to address the low flow of the well. Pressure tanks are commonly incorporated into water systems to supplement low-flow wells. Should this application be approved, we recommend the following conditions be part of any approval: Prior to recording the plat: 1. The applicant shall designate envelopes for replacement absorption fields for both residences. The envelopes shall be designated on the plat and language for the preservation and/or protection of the second absorption field envelope shall be noted on the plat. Specifically, the plat shall state that activities such as landscaping (i.e. planting of trees and shrubs) and construction (i.e. auxiliary structures, dirt mounds, etc.) are expressly prohibited in the designated absorption field site. 2. The second residence does not have an approved septic system. A septic systems permit shall be obtained from the Weld County Department of Public Health & Environment. The septic system must comply with all requirements of the Weld County Code. Permitting of the system shall be conducted in accordance with Department policy regarding septic systems installed without an appropriate permit. Further, because the system is located within the flood plain it must comply with the Weld County I.S.D.S. flood plain policy. ' EXHIBIT I Page 2 of 2 Recommended development standards: 1. Any septic system located on the property must comply with all provisions of the Weld County Code, pertaining to Individual Sewage Disposal Systems. Additionally, please note the following: 1. This application is proposing a well(s) as its source of water. The applicant should be made aware that while they may be able to obtain a well permit from the Office of the State Engineer, Division of Water Resources, the quantity of water available for usage may be limited to specific uses, i.e. domestic use only, etc. Also, the applicant should be made aware that groundwater may not meet all drinking water standards as defined by the Colorado Department of Public Health and Environment. We strongly encourage the applicant to test their drinking water prior to consumption and periodically test it over time. g,ouNrq/N MOUNTAIN VIEW FIRE PROTECTION DISTRICT Administrative Office: 9119 County Line Road• Longmont, CO 80501 (303) 772-0710• FAX (303) 651-7702 VIEW October 16, 2003 Mr. Kim Ogle Weld County Planning Department 1555 North 17th Avenue Greeley, CO 80631 Dear Mr. Ogle: I have reviewed the submitted material pertaining to the Site Specific Development Plan and Use by Special Review for a single-family dwelling unit at 5090 Weld County Road I (Case Number: USR-1450, Case Name: Schlichenmayer). The Fire District has the following comments and concerns regarding this case: • First and foremost, a building permit was obtained for the construction an 8,000 square foot pole barn. The plans were reviewed and inspected by the building department for this specific use and not for use as a one or two family dwelling unit. Because building permits were not obtained for this structure to be used as living space, the Weld County Building Department and the Fire District can not possibly know if the structure meets basic life safety requirements let alone the requirements of the Building Code and Fire Code for an R-3 Occupancy (single-family dwelling). For example: Are there required residential smoke detectors in the building? Are there proper egress/rescue windows in the building? Is there proper separation from the garage/storage areas and the living space? This is not an all- inclusive list of questions,just an example of basic requirements that, again, the Fire District and Building Department have no idea if the structure can meet the Codes. • Second, when a single-family dwelling is constructed on a parcel of land, whether created by a recorded exemption or by a special situation on the same parcel, water supply for fire protection is only required when the dwelling exceeds 3,600 gross square feet in size. It should be noted gross square feet, according to the Fire Code, is everything under roof on all floors. Now that this structure has been partially finished as living space and a second story has also been constructed, the gross square footage of this structure appears to be approximately 13,120 gross square feet. In accordance with the Fire Code,the required water supply for this structure is 3,000 gallons per minute, measured at a residual pressure of 20 iss1 pounds per square inch. The required water supply is not available to this structure. When the required fire flow is not available or the owner wishes an alternative to the installation of ~ fire hydrants, the installation of a residential fire sprinkler system has been accepted as an alternative to meeting the required fire flow. If a residential fire sprinkler system is proposed, _ ≥r the plans for the fire sprinkler system must be submitted to the Fire District for review and X approval prior to installation. W •rx'aaao4e-avon d lamI Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 9119 Cnty Line Rd. 10971 WCR 13 P.O.Box 575 P.O.Box 11 10911 Dobbin Run 50 Bonanza Dr. P.O.Box 40 Longmont,CO Longmont,CO 299 Palmer Ave. 8500 Niwot Road Lafayette,CO Erie,CO 100 So.Forest St. 80501 80504 Mead,CO 80542 Niwot,CO 80544 80026 80516 Dacono,CO 80514 Mr. Kim Ogle October 16, 2003 Page Two • Lastly, the Fire District would not object to the use of this structure as living space if the building meets the requirements of the Fire District and the Building Department for use as an R-3 Occupancy. Regardless of whether or not the Special Use is approved because all of these people are family and related by blood or marriage, basic life-safety must be achieved before the Fire District would be comfortable with the use of this structure as living space. We appreciate being involved in the planning process. Should you have any questions, please contact me at(303) 772-0710. Sincerely, \A-C- LuAnn Penfold Fire Marshal LMP/lp cc: project file Ip10.15.03 STATE OF COLORADO OFFICE OF THE STATE ENGINEER co\ Division of Water Resources Department of Natural Resources (a 6 1313 Sherman Street, Room 818 � ��� Denver,Colorado 80203 �t870� Phone(303)866-3581 FAX(303)866-3589 • - Bill Owens www.water.state.co.us Governor October 24, 2003 Greg E.Walther Executive Director Kim Ogle Hal D.Simpson,P.E. g State Engineer Weld County Planning Dept. 1555 N. 17th Ave. Greeley, CO 80631 RE: Site Specific Development Plan, Schlichenmayer, USR-1450 Dear Kim Ogle Pursuant to the State Engineer's August 7, 1995 memorandum to county planning directors, this office is no longer providing comments on land use actions that do not involve a subdivision as defined in Section 30-28-101(10)(a), C.R.S. This referral does not qualify as a "subdivision", however the following comments are provided, since it appears that the property will be served by an existing well. According to the submitted material, the property currently has two dwellings that are served by an existing well. The well was constructed in the late sixties and was recently late registered with the State Engineer's office under permit no. 252966. The historic uses of the well as registered are ordinary household purposes inside one single family dwelling, fire protection, the watering of domestic animals and poultry and the irrigation of not more than 500 square feet of home gardens and lawns. The existing well cannot be expanded beyond the uses registered by permit no. 252966. Therefore, if the well will be used to serve two single-family or multifamily dwellings, a well permit must be acquired for the expanded uses. The well permit would be evaluated in accordance with current statutes and policies in place at the time of application. According to current statutes and policies, and given the size of the property and the depth of the well, a court approved augmentation plan would be required in order to obtain a well permit for uses other than household use only. If you have any questions in this matter please call Joanna Williams in this office. Sincerely Kevin G. Rein Water Resource Engineer KGR/JMW EXHIBIT p r4't ft 141.1.1 \\ MEMORANDUM O TO: Kim Ogle, Planner III DATE: 11/5/2003 r COLORADO• FROM: Donald Carroll, Engineering Administrator Pit SUBJECT: USR-1450, Loyd & Sheila Schlichenmayer The Weld County Public Works Department has reviewed the proposal; this project falls primarily under the Use by Special Review Standards, Weld County Code, Chapter 23, Article II, Division 4, Section 23. Our comments and requirements are as follows: COMMENTS: WCR 1 is designated on the Road Capital Improvement Plan in the County Wide Impact Fee Code Ordinance, Section 20-1-30, as a future major arterial road, which requires a 140-foot right-of-way at full build out. This section of road falls under the maintenance of Boulder County. We do not maintain this section of road; therefore, I do not have any traffic counts. ft,— REQUIREMENTS: Future Right-of-Way: The applicant may reserve and show on the plat drawing the future right-of-way adjacent to WCR 1 designating 70 feet from the section line/center line of WCR 1 to the future right-of-way line. The applicant should be aware that there shall be no permanent structures allowed in this future right-of-way. Existing Access: The limited access to WCR 1 involves sharing an access point for multiple parcels. Utilize the existing access. Notification: The applicant has provided the adjacent property owners notification of the proposed USR use. Include these documents in the file as the use still remains residential. Access Easement: The applicant indicated that there is a 20-foot access easement by record, Record No. 02034134. This document should be included in the packet and be a part of the record prior to recording. Storm Water Drainage: The historical flow patterns and run-off amounts will be maintained on site in such a manner that it will reasonably preserve the natural character of the area and prevent property damage of the type generally attributed to run-off rate and velocity increases, diversions, concentration and/or unplanned ponding of storm run-off. pc: USR-1450 M:\PLANNING\USR-10.DOC EXHIBIT I Cr A` .lain A" '- .... 1 � 'y S * • 74 A' .`4�„'�+a. do • _, �. .s �r , t 1 _ 'eSt i t , -UGFA' tl O- - y. t,. 1• -•--•- 1� W x e. � ' .1 `Ctt,,. S s' .- ...,4f. 4` I a ;0 1 WI j ;7 'S9 a F.k' . r" r, c k : 1 s k' ;i tz fl , . t }�•' > „ ', F , .t ' t .yam,[. •+�' . • ss r4 -• } ' ' .. { i•� P-^F a . ¢( `t-tit -, P r 1 / St. Vram Valley School District November 7,2003 Kim Ogle Weld Count/ Planning Department 1555 N. 17 Ave. Greeley, CO 80631 RE: Recommendation to oppose the Loyd and Sheila Schlichenmayer Site Specific Development Plan and Use by Special Review(Situate in the SW 1/e at Section 6, TIN, R88WJ Dear Kim: Thank you for referring the Loyd and Sheila Schlichenmayer Site Specific Development Plan and Use by Special Review to the School District. The District has reviewed the development proposal In terms of future student Impacts and available school capacity and has the following RECOMMENDATION: the District is OPPOSED to_the approval of this application due to this development's impact on already overcrowded school facilities. The Board of Education has established a District-wide policy of opposing new developments that add to the student enrollment of schools projected to be at or above 125% of their capacity. This particular application, which is currently located in the Erie Elementary and Erie Middle/Senior High Feeder, will add 1 new single-family dwelling unit with a potential student impact of 1 additional student in this feeder. The District opposes this development because, as indicated in the chart below, Erie Elementary and Erie Middle/Senior High Schools will exceed 125%of their capacity with the addition of students from this development. CAPACITY INFORMATION CAPACITY BENCHMARK (Inaludes proleowd*tannin.plus development's eludant impact; School Building Stilts. Slot. 2003 2004 2006 2006 2007 Level Capacity OCb02 Impact Stills Cep. Stilts Cap. Stills Cap. Stilts Cap. stills cap. Elementary 552 482 1 618 04% 580 106% 635 115% 703 127% 775 140% Middle/Senior' 818 530 0 655 00% 631 102% 697 113% 786 127% 862 138% Total 1170 1 1074 1211 _1332 1488 1827 -New Erie Hien School capacity boing added in 2006 is not yet counted due to uncertainly about whether the school will Include a middle school or not. The School Districts current opposition to this proposal may be modified should the developer come to an agreement with the School District regarding capacity concerns. School District policy acknowledges two possible ways to accomplish this.The first is for the developer to agree to mitigate the development's potential student impact on capacity by agreeing to a voluntary, per unit contribution to the School District (in addition to cash-in-lieu funds noted below). Funds collected under this policy would most likely add classroom space within the subject feeder or, in situations where additional capacity is known to be eminent, provide portables. The second way to resolve capacity concerns would be for the developer to commit to not constructing any residential prior to the availability of school capacity. Should agreement be reached on either of these possibilities,this office will write a new letter to Weld County updating this referral. The developer can contact this office directly to discuss either of these possibilities further. The recommendation of the District noted above applies to the attendance boundaries current as of the date of this letter. New school facilities approved under the 2002 bond could affect the project's attendance area and capacity in the future. Elementary capacity relief may come as early as 2005, however, no construction schedule has been finalized for this project and the opening date of this facility remains undetermined. A new secondary facility has been slated for completion in the Fall of 2005, but this facility may not increase capacity, depending whether it opens as a middle/senior or dedicated High school. Until the Board of Education makes a final decision regarding the grade levels that will attend the facility, capacity relief at the secondary will also remain undetermined. Under current attendance boundaries,transportation would most likely be provided. Should the County decide to recommend approval of this development proposal, the School District's cash-in-lieu and/or land dedication requirements would still need to be satisfied. This requirement involves the dedication of land with the adjacent infrastructure or payment of an equivalent cash-in-lieu fee based on the student yield of the development. Since this property is not a likely future school site,the fee would be assessed per the attached chart. Please let me know of any further questions. Sincerely, EXHIBIT ten Segrue,Al Planning Specialist ST.VRAIN VALLEY SCHOOL DISTRICT PLANNING DEPARTMENT.395 SOUTH PRATT PARKWAY, LONGMONT,CO 80501. SCOTT TOILLION,DIRECTOR.PHONE 303-682.7229, FAX 303-882.7344. 2030044 86179 1702 IDLE.:01 17 2L-289-202 S3JInel3S 1Sno SNUaL:WOd3 2S:TI 20 LB-(lON M School Planning Schlichenmayer SU Standards And Weld County Calculation of cc a In Lieu Fees m m c Single Family rn r- School Planning Standards a Number Projected Student Site Size Acres of Developed Of Student Facility Standard Land Land Cash-in-lieu Units Yield Standard Acres Contribution Value Contribution Elementary 1 0.35 525 10 0.01 $35,000 cr 0.35 m Middle Level 1 0.14 750 25 0.00 $35,000 M 0.14 N W High School 1 0.17 1200 50 0.01 $35,000 re N 017 I- (f) Total 0.66 0.02 $35,000 $645• Single Family Student Yield is .66 $645 Per Unit Cu 1 ti ti M m ti 11/7/03 0 St. Vrau Valley School District Fax To: Kim Ogle From Judy Rusk for Glen Segrue Roc 970-304.6498 Penes: 3(Including cover) Phone: Date: 11/07/05 Res SchlichenmayerSU CC: ❑Urgent O For Review El Please Comment O Please Reply O Please Recycle • Cornmeofs: If you have any questions, please don't hesitate to contact me at(303)682-7229. r-. ST.VRAIN VALLEY SCHOOL DISTRICT PLANNING DEPARTMENT.395 SOUTH PRATT PARKWAY,LONGMONT, CO 80501.SCOTT TOILLION,DIRECTOR.PHONE 303-682-7229. FAX 303-682-7344. TO:30Cd 86179 170£ OL6:O1 17472L-209-202 S3OInass 1St SNtRJ1:WOad 2S:TT £0 LO-nON Q DEPARTMENT OF BUILDING INSPECTION Weld County Administrative Offices 1555 N. 17th Avenue, Greeley, CO WEBSITE: www.co.weld.co.us Phone (970) 353-6100, Ext. 3540 111kFax (970) 304-6498 COLORADO November 19, 2003 Loyd & Sheila Schlichenmayer Site Specific Development Plan and Use by Special Review for a single family dwelling unit (other than those permitted under Section 23-3-20.A) in the A (Agricultural) Zone District. USR-1450 There is an existing building permit to construct the 8,000 square foot pole frame garage and storage building. There is also a building permit that was applied for to convert a portion of the above building into a dwelling. 1. Building permits shall be obtained for the conversion of the garage/shop into a dwelling. 2. A plan review is required. Details shall be submitted to the Building Inspection Department to explain all structural and life safety aspects of this conversion. 3. This building shall conform to the requirements of the codes adopted by Weld County at the time of permit application. Current adopted codes include the 1997 Uniform Building Code; 1998 International Mechanical Code; 1997 International Plumbing Code; 2002 National Electrical Code and Chapter 29 of the Weld County Code. 4. Building height shall be limited to the maximum height allowed per UBC Table 5-B. Wall and opening protection and limitations shall be in accordance with UBC Table 5-A. Separation of buildings of mixed occupancy classifications shall be in accordance with UBC Table 3-B and Chapter 3. Setback and offset distances shall be determined by the Zoning Ordinance. 5. Building height shall be measured in accordance with the 1997 Uniform Building Code for the purpose of determining the maximum building size and height for various uses and types of construction and to determine compliance with the Bulk Requirements from Chapter 27 of the Weld County Code. Building height shall be measured in accordance with Chapter 23 of the Weld County Code in order to determine compliance with offset and setback requirements. Offset and setback requirements are measured to the farthest projection from the building. 6. A Flood Hazard Development Plan shall be submitted for the conversion of this building to a dwelling. [ 4 EXHIBIT Service,Teamwork, Integrity,Quality Page 2 Please contact me for any further information regarding this project. Sincerely, „7,4444 Jeff Reif Building Official Service,Teamwork, Integrity, Quality Hello