Loading...
HomeMy WebLinkAbout20041864.tiff Weld County Planning Department GREELEY OFFICE JAN 1 4 ZOOS fitrtatis MEMORANDUM RECEIVED rir TO: Jacqueline Hatch, Plann r DATE: 13-January-2004 W� O FROM: Peter Schei, P.E., Ci it eer,Public Works Department COLORADO SUBJECT: SPR-365 Troy& u ' (Site Plan Review) Weld County Public Works Department has reviewed Site Plan Review materials and has the following development referral comments. Comments ❑ Interstate 25 frontage road is not a County roadway. The applicant should contact the appropriate authority regarding review of this proposed site plan review adjacent to Interstate 25 frontage road; especially access. ❑ Parking for this site plan shall meet County standards as specified in Weld County Code 23.4.30.B and Appendix 23- A and Appendix 23-B. Parking stall standard dimensions are: stall width is 9-feet, stall to curb is 19-feet, and aisle width is 24-feet. Ten percent(10%) of the parking spaces may be for small cars. Small car stall dimensions are: stall width is 8-feet and stall to curb is 16-feet. The applicant shall comply with these standards for this site plan review. Include stall dimensioning and the number of classification stalls on the plans. Loading/service areas shall be paved. ❑ ADA requirements shall be met for this site. Parking Lots shall conform to all standards of the Americans with Disabilities Act. Handicap access to sidewalks around the building and to designated parking must be undertaken. Grading shall not be greater than 2% for the handicap stalls and access aisles. The number of handicapped stalls must be shown on the plans,along with dimensioning. Recommendation ❑ Public Works approves this site plan based on compliance of meeting mandatory parking standards and satisfying ADA requirements for access. ❑ Public Works approves this site plan based on compliance with Weld County Code. ❑ Public Works will not require further review of this site plan. Any issues shall be resolved with Public Works prior to construction. 2004-1864 PC:SPR-365'Frey&Judy Ilefner(Site Plan Review) Email: Plain r EXHIBIT Page 1 of 1 // Weld County Purr;". GeThi Ht` it 6 FEB 2 2004 MEMORANDUM p r IDTO: Jacqueline Hatch, Planner % 7 DATE: 19-February-2004 CFROM: Peter Schei, P.E.,Ci ' , Public Works Department COLORADO SUBJECT: SPR-365 Troy&Judy Hefner(Site Plan Review)2.doc Weld County Public Works Department has reviewed this Site Plan Review request. Comments made during this phase of the process may not be all-inclusive, as other concerns or issues may arise during the remaining application process. Comments ❑ These additional comments follow Public Works memo dated 13-January-2003. u The applicant will be required to describe the transportation circulation proposed for this site. The on-site circulation must be described and detailed on the site plan. u Easements shall be shown in accordance with County standards,also dimensioned on the site plan. u A statement accompanied by evidence explaining how stormwater runoff will be handled shall be submitted as per CODE Sec. 23-2-160-N. If physical changes to the site are proposed (grading, paving, increased roof areas, etc.), then evidence, maps and calculations explaining how stormwater retention facilities are designed to retain the stormwater runoff in excess of the historic flow from the undeveloped site shall be designed for a one-hundred-year storm and release retained water at a rate not to exceed a five-year storm falling on the undeveloped site. Recommendation u The Public Works Department recommends approval of this Site Plan, based on compliance with Weld County Code and satisfying ADA requirements for access. The applicant shall address the comments listed above for this review process. The review process will continue only when all appropriate elements have been submitted. Issues of concern must be resolved with the Public Works Department prior to recording; PC: SPR-365 Troy&Judy Hefner(Site Plan Review) 2.doc Email&Original: Planner Pl4n a.i..)2- Page 1 of 1 w . (it MEMORANDUM a TO: JACQUELINE HATCH, PLANNING SERVICES IFROM: CHARLOTTE DAVIS, ENVIRONMENTAL HEALTH(Q SUBJEC. CT. R3 TROY ANT) JUDY HEFNER DATE: 01/13/2004 COLORADO cc: Environmental Health Services has reviewed this proposal for a new and used auto parts retail sales; auto repair & service; and showroom. We have no objections to the proposal, however, we do recommend that the following conditions be part of any approval: We recommend that the following requirements be met prior to allowing the plat to be recorded: 1. The applicant shall submit a waste handling plan, for approval, to the Environmental Health Services Division of the Weld County Department of Public Health & Environment. The plan shall include at a minimum, the following: 1) A list of wastes which are expected to be generated on site (this should include expected volumes and types of waste generated). 2) A list of the type and volume of chemicals expected to be stored on site. 3) The waste handler and facility where the waste will be disposed (including the facility name, address, and phone number). We recommend that the following requirements be incorporated into the permit as development standards: 1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. 2. No permanent disposal of wastes shall be permitted at this site. This is not meant to include those wastes specifically excluded from the definition of a solid waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended. 3. Waste materials shall be handled, stored, and disposed in a manner that controls fugitive dust, fugitive particulate emissions, blowing debris, and other potential nuisance conditions. 4. The applicant shall operate in accordance with the approved "waste handling plan". 5. Fugitive dust and fugitive particulate emissions shall be controlled on this site. 6. Fugitive dust and fugitive particulate emissions shall be controlled on this site. The facility shall be operated in accordance with the approved dust abatement plan at all times. 7. This facility shall adhere to the maximum permissible noise levels allowed in the Commercial Zone as delineated in 25-12-103 C.R.S., as amended. 8. Adequate handwashing and toilet facilities shall be provided for employees and patrons of the facility. 9. Any septic system located on the property must comply with all provisions of the Weld County Code, pertaining to Individual Sewage Disposal Systems. 10.A permanent, adequate water supply shall be provided for drinking and sanitary purposes. 11.All potentially hazardous chemicals must be stored and handled in a safe manner in accordance with product labeling and in a manner that minimizes the release of hazardous air pollutants (HAP's) and volatile organic compounds (VOC's). 2 ,. ✓ Code? 14.1:11 Weld County Referral C. December 8, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Troy&Judy Hefner Case Number SPR-365 Please Reply By January 8, 2004 Planner Jacqueline Hatch Project Site Plan Review Legal Lot 4; Althen Boyer; Section 32, T1 N, R68W of the 6th P.M., Weld County, Colorado. Location East of and adjacent to Interstate 25 (frontage road); approximately 1/4 mile north of CR 6. For a more precise location, see legal. Parcel Number 1467 23 000061 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. a See attached letter. Comments: c)\40,5-sic_ cm Q akiNjor,�Yz Signature Agency ZLAThrl 1 o-t . Date +Weld County Planning Dept. ❖1555 N. 17th Ave.Greeley,CO. 80631 ❖(970)353-6100 ext.3540 +(970)304-6498 fax I tit Z� MEMORANDUM COLORADO To: Jacqueline Hatch, Planner December 11, 2003 From: Bethany Salzman, Zoning Compliance Officer Subject: SPR-365 Referral Upon review of my computer and files,a Building Permit(BCS-020666)was noted. This permit was initiated to replace a previously expired permit(BC-0100711)which was initiated for the interior remodel of an existing structure. This permit was locked and not released from Zoning due to the lack of a Site Plan Review application being submitted as required. If this"SPR" is approved, and once the plat has been recorded, the building permit(BCS-020666)should be released for inspections and finalization. If the"SPR" is denied, an appropriate time-line will be established prior to initiating a violation for the building permit and construction. cc: BCS-020666 Peggy Gregory, Building Compliance Officer SERVICE,TEAMWORK,INTEGRITY,QUALITY J v-`) Weld County Referral CDecember 8, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Troy&Judy Hefner Case Number SPR-365 Please Reply By January 8, 2004 Planner Jacqueline Hatch N, Project Site Plan Review c„ "'g • Legal Lot 4; Althen Boyer; Section 32, Ti N, R68W of the.6th-P.M.,,Weld County, Colorado. Location East of and adjacent to Interstate 25 (frontage road); approximately 1/4 mile north of CR 6. For a more precise location, see legal. Parcel Number 1467 23 000061 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. Comments: Signature / 7, it-fl _, u'O? Agency 17 Si\�� Date S +Weld County Planning Dept. +1555 N. 17th Ave.Greeley,CO. 80631 ❖(970)353-6100 ext.3540 4(970)304-6498 fax MEMORANDUM TO: Jacqueline Hatch, Planner Wi`lC. DATE: December 13, 2003 COLORADO FROM: Kim Ogle, Planning Manager SUBJECT: Site Plan Review 365 Landscape Referral Troy & Judy Hefner, applicant The Department of Planning Services reviewed the above referenced Site Plan Review documentation and drawings and offers the following comments: The Site Plan Review Plat shall be prepared in accordance with Section 23-2-160.W of the Weld County Code. This application shall be in compliance with Section 23-3-250 A. and B and is address in the following comments. Section 23-3-250.A.1 Stormwater Management. All users of land in Commercial Zone Districts shall provide and maintain stormwater retention facilities designed to retain the stormwater runoff in excess of historic flow from the undeveloped site. The stormwater retention facility on a developed site shall be designed for a one-hundred-year storm. The stormwater retention facility shall be designed and operated to release the retained water at a quantity and rate not to exceed the quantity and rate of a five-year storm falling on the undeveloped site. The application materials state that the storm water runs to the north and into a holding pond east of the property. There was no supporting documentation stating how this is accomplished. The applicant shall contact the Weld County Department of Public Works to durther discuss this issue. Section 23-3-250.A.2 Parking. Sufficient screened, off-street, paved parking areas shall be provided in the Commercial Zone Districts to meet the requirements of employees, company vehicles, visitors and customers of the Uses Allowed by Right and Accessory Uses. Appendix 23-A describes the design requirements for parking spaces and Appendix 23-B delineates the number of parking spaces required by use for this property. The proposed facility has Office, Retail and Sales and Warehouse uses. The parking requirement for Office uses are one pspace for every two employees plus one space per 500 SF. The area delineated on the drawings submitted is 350 SF, with written documentation stating there are three employees on premises, therefore three (3) parking spaces are required for the office area. The Retail Sales and Service area requires one parking space per each 200 i% SF of area, therefore nine (9) spaces are required. The warehouse area require one space for every 1000 SF of area, therefore eleven (11) spaces are required. Total parking required for this facility is 23 spaces of which one must meet the requirements of the Americans with Disabilities Act. Section 23-3-250.A.3 Street Access. Lots in commercial zone districts shall have safe access to an approved public or private street. The design designation of any street or highway as to type shall be in conformance with that shown on the county thoroughfare plan and/or the master plan of the affected municipality. The applicant shall contact the Colorado Department of Transportation concerning access to the recently realigned Frontage Road at this location. Written eveidence of an approved access permit shall be provided to the Department of Planning Services. Section 23-3-250.A.4 Required Yards - Setback No use or accessory use may be located closer than twenty-five (25) feet to the existing or proposed (whichever represents the greater right-of-way width) highway or street right-of-way. Off-street parking areas may be permitted in the required setback area when the area is screened from direct view of persons on the public rights-of-way. Fences over six (6) feet in height are not required to comply with the minimum setback and may be located on the property line. Fences located on corner lots abutting public right-of-way shall not obstruct the view of vehicular traffic at an intersection. There was not an elevational drawing of the structure included in the application materials, therefore, prior to the release of building permits, the set back shall be verified given the realignment and redesign of the 1-25 Frontage Road. Written evidence of compliance shall be submitted to the Department of Planning Services. Section 23-3-250.A.4 Required Yards - Offset No use or accessory use may be located closer than ten (10) feet to its lot line. Off-street parking areas may be permitted in the required offset area when the area is screened from adjacent lots zoned R-1, R-2, R-3, R-4 or R-5. Fences over six (6) feet in height are not required to comply with the minimum OFFSET and may be located on the property line. The plans submitted with the application materials have delineated the offset as 22 feet five inches. (22'-5"). There was not an elevational drawing of the structure included in the application materials, therefore, prior to the release of building permits, the offset shall be verified. Section 23-3-250.A.5.A Required Landscaped Areas No more than eighty-five percent (85%) of the total area of a lot in any Commercial Zone District shall be covered. Land shall not be deemed covered if it is used for growing grass, shrubs, trees, plants or flowers or if covered by decorative gravel or wood chips, or if it is otherwise suitably Landscaped. There was not a Landscape and Screening Plan submitted with the application materials. Additional information is required prior to accepting the plat for recording. Section 23-3-250.A.5.B That portion of a lot in any Commercial Zone District which abuts a public or private street right- of-way shall be landscaped for a distance of ten (10) feet, measured at a right angle from the lot line towards the interior of the lot. Sidewalks and driveways may pass through the required landscaped areas. There was not a Landscape and Screening Plan submitted with the application materials. Additional information is required prior to accepting the plat for recording. Section 23-3-250.A.6 Areas used for trash collection shall be screened from public rights-of-way and all adjacent properties. These areas shall be designed and used in a manner that will prevent wind- or animal-scattered trash. The application materials state the dumpster is located behind the fence, however there is not one delineated on the plat. Future submittals shall delineate the screened enclosure as outlined in this Section of the Code. Section 23-3-250.A.7 Water Supply. Uses located in the Commercial Zone Districts shall have an adequate source of potable water. The application materials state that water is provided by Commercial Well Permit number 015774-F in a letter dated April 30, 1974. The letter further states that 1000 gallons per day is allowed per each parcel. The applicant shall provide written evidence that this commercial facility is within this standard. Further, the applicant shall meet the requirements of the Weld County Department of Public Health and Environment. Section 23-3-250.A.8 Sewage Disposal. Uses located in Commercial Zone Districts shall have adequate sewage disposal facilities. The application materials state that an existing ISDS system permitted under G-890279 will handle the effluent flow. Further, the applicant shall meet the requirements of the Weld County Department of Public Health and Environment. Section 23-3-250.A.9 Outside Storage. Uses in Commercial Zone Districts involving outdoor storage of vehicles, equipment or materials when permitted shall be screened from public rights-of-way and all adjacent properties. The application materials and supporting drawings indicate that a fence is located at the perimeter of the property, however, there is no indication that the fence is of an opaque material. Future submittals shall delineate the screened fenced enclosure as outlined in this Section of the Code. Section 23-3-350.B. Operation Standards. USES in Commercial Zone Districts shall demonstrate conformance with the following operation standards to the extent that they are affected by location, layout and design prior to construction and operation. Once operational, the operation of the USES permitted shall conform to these standards. Section 23-3-350.B.1 Noise. Uses and structures in Commercial Zone Districts shall be located, designed and operated in accordance with the noise standards as established in Section 25-12-101 C.R.S. The applicant shall meet the established standards set by the Weld County Department of Public Health and Environment. Section 23-3-250.6-2 Air Quality. Uses in the Commercial Zone Districts shall be located, designed and operated in accordance with the air quality standards established by the Colorado Air Pollution Control Commission. The applicant shall meet the established standards set by the Weld County Department of Public Health and Environment. Section 23-2-250.B.3 Water Quality. Uses in the Commercial Zone Districts shall be located, designed and operated in accordance with the water quality control standards established by the Colorado Water Quality Control Commission. If applicable, the applicant shall provide additional information regarding the commerncial well if required through the Weld County Department of Public Health and Environment referral. Section 23-2-250.B.4 Radiation and Radioactive Materials. The handling, use, storage and processing of radioactive materials shall be in accordance with the applicable regulations of the State and the United States government The application materials do not indicate this is applicable, should this not be the case, the applicant shall provide additional information to the Weld County Department of Public Health and Environment. Section 23-2-250.B.5 Heat. Uses located within Commercial Zone Districts shall not emit heat in such an amount sufficient to raise the temperature of the air or of materials at or beyond the Lot line more than five (5) degrees Fahrenheit. The application materials do not indicate this is applicable, should this not be the case, the applicant shall provide additional information to the Weld County Department of Public Health and Environment and the Department of Building Inspection. Further, the applicant shall obtain a written approval from the Mountain View Fire Protection '- District stating that the facility is in compliance with the Fire Code. Section 23-2-250.B.6 Light. Any lighting, including light from high temperature processes such as welding or combustion, shall be designed, located and operated in such as manner as to meet the following standards: sources of light shall be shielded so that beams or rays of light will not shine directly onto adjacent properties; neither the direct nor reflected light from any light source may create a traffic hazard to operators of motor vehicles on public or private streets; and no colored lights may be used which may be confused with or construed as traffic control devices. The application materials did not include a Lighting Plan. Should exterior lighting be a-....- part of this facility, all light standards shall be delineated on the Site Plan Review Plat. Section 23-2-250.B.7 Property Maintenance. Property located within Commercial Zone Districts shall be maintained in such a manner that grasses and weeds are not permitted to grow taller than twelve (12) inches. In no event shall the property owners allow the growth of noxious weeds. The application materials do not address property maintenance. Future correspondence shall identify how the property will be in compliance with this Section of the County Code. Section 23-4-50. Off Street Loading. The applicant shall delineate on the Site Plan Review plat the location of the loading zone that is in compliance with Section of the Code. Section 23-4-100 Signs in the Commercial and Industrial Zone Districts. The application materials state a 4x8 foot sign board is screwed to the side of the existing structure. Section 23-4-100.D addresses attached signs. The applicant shall provide written evidence the sign is in compliance with this section of the Code. The plan reviewed for this application states the drawing identified as "Floor Plan" states the drawing is of the Lower Floor. There is a stair case delineated on the plan, therefore staff requires written documentation from the applicant disclosing what is on the upper floor or mezzanine level as applicable. This information shall be forwarded to the Department of Building Inspection and the Mountain View Fire Protection District for review . The applicant shall enter into an Improvements Agreement according to policy regarding collateral for improvements and post adequate collateral for all transportation (access drive, parking areas, etcetera) and non-transportation (plant materials, fencing, screening, etcetera). The agreement and form of collateral shall be reviewed by County Staff and accepted by the Board of County Commissioners prior to recording the Site Plan Review plat. let:IIIII Weld County Referral will C December 8, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Troy&Judy Hefner Case Number SPR-365 Please Reply By January 8, 2004 Planner Jacqueline Hatch Project Site Plan Review Legal Lot 4; Althen Boyer; Section 32, Ti N, R68W of the 6th P.M., Weld County, Colorado. Location East of and adjacent to Interstate 25 (frontage road); approximately 1/4 mile north of CR 6. For a more precise location, see legal. - Parcel Number 1467 23 000061 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. Cl We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ e have reviewed the request and find no conflicts with our interests. See attached letter. Comments: ./7 Signature - V/ L __ uv, l 7, 2.6 0 4 Agency � Q t LJ AIN& n_ t- Date +Weld County Planning Dept. +1555 N. 17th Ave. Greeley,CO. 80631 +(970)353-6100 ext.3540 ❖(970)304-6498 fax art , DEPARTMENT OF BUILDING INSPECTION Weld County Administrative Offices 1555 N. 17th Avenue, Greeley, CO80631 WEBSITE: www.co.weld.co.us Phone (970) 353-6100, Ext. 3540 IFax (970) 304-6498 C. COLORADO January 19, 2004 Troy & Judy Hefner Site Plan Review SPR-365 1. A permit application was submitted for the interior remodel of this building. BCS-020666 is pending the approval of SPR-365. If SPR-365 is approved, a plan review will be performed. All required inspections shall be scheduled and approved. 2. This building shall conform to the requirements of the various codes adopted at the time of permit application. Currently, the following has been adopted by Weld County: 1997 Uniform Building Code; 1998 International Mechanical Code; 1997 International Plumbing Code; 2002 National Electrical Code and Chapter 29 of the Weld County Code. 3. The building, parking areas and assess routes shall conform with the Americans With Disabilities Act and CABO/ANSI A117.1-1992. Please contact me for any further information regarding this project. Sincerely, ) A 94, Jeff Reif Building Official Service,Teamwork, Integrity,Quality view Gounty manningILIIICIR GREELEY OFFICE JAN 1 2 2004 4 1 6 RECEIVED liD Weld County Referral III C. December 8, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Troy& Judy Hefner Case Number SPR-365 Please Reply By January 8, 2004 Planner Jacqueline Hatch Project Site Plan Review Legal Lot 4; Althen Boyer; Section 32, T1 N, R68W of the 6th P.M., Weld County, Colorado. Location East of and adjacent to Interstate 25 (frontage road); approximately 1/4 mile north of CR 6. For a more precise location, see legal. Parcel Number 1467 23 000061 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑�/:We have reviewed the request and find no conflicts with our interests. EL See attached letter. Comments: Signature /Ay/�,�? '__.t7 ` 11/4 U/i� L ✓`/ Agency 7J�/�3��L Date ❖Weld County Planning Dept. ❖1555 N. 17th Ave.Greeley,CO.80631 ❖(970)353-6100 ext.3540 +(970)304-6498 fax t^� MEMORANDUM To: Jacqueline Hat From: Dave Tuttle Date: January 9, 200 Subject: SPR-365 The sheriffs office has no concerns with this Special Use Permit. The sheriff's office would however be willing to provide a program entitled Crime Prevention through Environmental Design to the developer. This program reduces the likelihood of criminal activity at a specific location by"hardening" it to crime. The Sheriffs Office lacks the ability to absorb any additional service demand without the resources recommended in the multi-year plan provided to the Board of County Commissioners or as indicated by growth not considered at the time the plan was developed. I have no other comments on this proposal. , lS /_a 4( atril Weld County Referral CDecember 8, 2003 COLORADO The Weld County Department of Planning Services has received the following item for review: Applicant Troy& Judy Hefner Case Number SPR-365 Please Reply By January 8, 2004 Planner Jacqueline Hatch Project Site Plan Review Legal Lot 4; Althen Boyer; Section 32, T1 N, R68W of the 6th P.M., Weld County, Colorado. Location East of and adjacent to Interstate 25 (frontage road); approximately 1/4 mile north of CR 6. For a more precise location, see legal. Parcel Number 1467 23 000061 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. U We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. gSee attached letter. Comments: Signature � G a �cQ �Z _ \ c( _63 Agency - ce < gS ,' Date +Weld County Planning Dept. +1555 N. 17th Ave.Greeley,CO. 80631 -t-1970)353-6100 ext.3540 c•(970)304-6498 fax • ouNrAA, MOUNTAIN VIEW FIRE PROTECTION DISTRICT AA-- e Administrative Office: 9119 County Line Road • Longmont, CO 80501 a I : F (303) 772-0710• FAX (303) 651-7702 VIEW December 19, 2003 Ms Jacqueline Hatch Weld County Planning Department 1555 North 17th Avenue Greeley, CO 80631 Dear Ms. Hatch: I have reviewed the submitted material pertaining to the site plan review and remodel of an existing building at 2114 I-25 Frontage Road in Weld County (Case Number: SPR-365, Case Name: Hefner). The Fire District does not object to the request to remodel the building provided the requirements of the Fire District can be met and additional square footage is not added to the building or site. Based on my review, I have the following comments regarding the project: • Construction shall be in accordance with the provisions of the Uniform Fire Code, as ratified by the Weld County Commissioners, and all other applicable codes and ordinances, as enforced by Weld County. • There is no water supply for fire protection to the site, but the building is existing. Because additional square footage is not being added to the building or the site, and the building is not being used for a more hazardous activity than previously existed, water supply for fire protection is not being required at this time. • A final inspection of the occupancy will be required by a member of the Fire District before a Certificate of Occupancy is issued from Weld County. The Fire District reserves the right to make further comments as the project proceeds. Nothing in this review is intended to authorize or approve of any aspect of this project that does not comply with all applicable codes and standards. We appreciate being involved in the planning process. Should you have any questions, please contact me at (303) 772-0710. Sincerely, oQj LuAnn Penfold Fire Marshal LMP/lp cc: project file Ip12.22.03 Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 9119 Cnty Line Rd. 10971 WCR 13 P.O.Box 575 P.O.Box 11 10911 Dobbin Run 50 Bonanza Dr. P.O.Box 40 Longmont.CO Longmont.CO 299 Palmer Ave. 8500 Niwot Road Lafayette,CO Erie.CO 100 So.Forest St. 80501 80504 Mead,CO 80542 Niwot,CO 80544 80026 80516 Dacono,CO 80514 ^ ^ Weld County Planning Departmaat GREELEY OFFICE 4oVNTYop, JAN 15 2004 40/0 o CITY AND COUNTY OFWED n � ` One DesCombes Drive. Broomfield, Colorado 8001c=�3y1 G D 'u -S January 13, 2004 Jacqueline Hatch Weld County Department of Planning Services 1555 N. 17th Avenue Greely, CO 80631 Subject: Referral Comments for Site Plan Review Dear Ms. Hatch: Thank you for referring for our consideration an application regarding the sale of used auto parts, auto repair and service and showroom in an existing building at 2114 1-25 Frontage Road (Lot 4). After review of the proposed project we have the following comments. The proposed site, in Weld County, is generally located northeast of Interstate 25 and Weld County Road 6 and is surrounded on three sides by The City and County of Broomfield. More specifically, the site lies within The City of Broomfield's Interstate-25 North Broomfield Sub- Area Plan. This Sub-Area Plan was prepared in cooperation with Weld County and in conjunction with the 1998 intergovernmental agreement with the Town of Erie. The Sub-Area Plan designates the project site for Employment uses and establishes design standards for these uses. In reviewing the proposed project, it is evident that it falls far short of meeting the Sub-Area Plan's design standards. For example, buildings in this area should be of a much higher quality and constructed with durable materials such as masonry. In summary, we cannot support the proposed project and I encourage you to review the Sub- Area Plan design standards and to apply these standards to this and other developments within the 1-25 planning area. We thank you for the opportunity to review projects within your County that have potential impact on our community. If you have any questions, please do not hesitate to contact me at 303-438-6245. Sincerely, Gs Kevin Standbr .ge Deputy City and . • my Manager Copy: Planning File Hello