HomeMy WebLinkAbout20051688.tiff Klettitrt;:),
Weld County Referral
WIIDe.
0.1,-; ,9171,a177, 2Q05
COLORADO
The Weld County Department of Planning Services has received the following item for review:
Applicant Union Pacific Railroad Case Number USR-1501
Please Reply By February 28, 2005 Planner Sheri Lockman
Project A Site Specific Development Plan and Special Review Permit for a business
permitted as a use by right or an accessory use in the Industrial Zone District
(Railroad car loading area for recyclable materials from Anderson's Salvage Yard)
in the A (Agricultural)Zone District
Legal Part of the E2 of Section 29, T6N, R65W of the 6th P.M., Weld County, Colorado.
Location 1/2 mile north of O Street(CR 64), east of CR 39 '/ and west of CR 41.
Parcel Number 0803 29 000081
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
Weld County Planning Commission Hearing (if applicable) April 5, 2005
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
❑ We have reviewed the request and find no conflicts with our interests.
See attached letter.
Comments
Signature Cad o4;,,,h Date ;_au-dC
Agency City of Cat ec -- Ll».w.4.40 % cvesoPM.Aur PL as,AG, prin3>ern)
tWeld County Planning Dept. t918 10'"Street. Greeley, CO.80631 +(970)353-6100 ext.3540 t(970)304-649 EXHIBIT
2005-1688 1
OFFICE OF COMMUNITY DEVELOPMENT
Planning Division
City of 1100 10`"Street, Suite 202, Greeley, Colorado 80631 •(970)350-9780• Fax(970) 350-9800
Greeley •www.greeleygov.corn
February 22, 2005
Sheri Lockman
Weld County Planning Department
918 10th Street
Greeley, CO 80631
Subject: USR-1501
Ms. Lockman,
Thank you for the opportunity to comment on this USR. The City of Greeley Planning staff has
reviewed the application and wishes to forward the following comments:
1. It should be noted that the subject site is entirely within the City of Greeley Long-Range
Expected Growth Area (LREGA). The LREGA includes those lands anticipated to
accommodate the City of Greeley's urban development over the next twenty(20) years.
2. Outdoor storage should not be permitted within any applicable setback, public right-of-way,
or in landscaped area.
3. Items not customarily used or stored outside or made of a material that is resistant to damage
or deterioration from exposure to the outside environment should not be placed, stored, or
maintained outside for a period in excess of 24 consecutive hours.
4. Access drives and parking areas should be paved with asphalt or concrete to reduce the
developments impact on air quality.
5. Outdoor storage of all material stored or to be stored in an unenclosed area shall be screened
from the view of the adjacent public right-of-way and adjacent properties. Screening shall
be accomplished through the use of a solid fence or a wall of sufficient height to fully screen
all stored material, or through the use of landscaping which provides year-round screening
of a sufficient height to fully screen all stored material, or through a combination of fencing,
walls, and landscaping.
SERVING OUR COMMUNITY • I T ' S A TRADITION
roe promise to preserve and improue lfie yual y of fib IOr >reeley IArou9/timely, courteous anrfcost elecfiue service.
6. Additional landscaping should be provided adjacent to the proposed stockpiling area. There
are several homes to the east of the subject site that will have a full view of the proposed
use. To use only the existing trees that are located in a draw that is located over 1,000 feet
from the stockpiling area seems to be inadequate to say the least. It is recommended that a
variety of shade, ornamental, and evergreen trees be provided north and east of the
stockpiling area to provide adequate screening of the proposed industrial use.
7. The height of the stock piled material should be no taller than 12-15 feet.
8. A designated haul route should be established prior to any approval. It is recommended that
the haul route be required to stay on Highway 85 and not on any rural roads.
Thank you for including the City of Greeley in the review process. If any questions arise, please
do not hesitate to contact me at 350-9822.
Sincerely,
•
tsn 7 f ,
Darrell L. Gesick
Planner I
Lip%
MEMORANDUM
rit TO: SHERI LOCKMAN, PLANNING SERVICES
I FROM: CHARLOTTE DAVIS, ENVIRONMENTAL A HEALTH
SUBJECT:USR-1501 UNION PACIFIC RAILRO9Pille MC it
C. DATE: 03/07/2005
G, jnJ
COLORADO CC:
Environmental Health Services has reviewed this proposal for a railroad car loading
area. We have no objections to the proposal, however, we have concerns about the
application presented regarding the use of portable toilets for employees. County code
allows portable toilets for temporary uses, 6 months or less. This year-round operation
is proposing to operate Monday through Saturday from 7 am - 7 pm, with up to five
individuals on the site at one time. We are cognizant that employees will likely be on
site for short periods of time for loading and unloading purposes. With this in mind,
Environmental Health would consider a permanent vaulted sewage disposal system
with a handwash station and an audible and/or visual alarm on the vault for
maintenance as an alternative to a standard septic system.
We recommend that the following requirements be met prior to allowing the plat to be
recorded:
1. The applicant shall submit a dust abatement plan for review and approval, to the
Environmental Health Services, Weld County Department of Public Health &
Environment.
2. The applicant shall submit a waste handling plan, for approval, to the
Environmental Health Services Division of the Weld County Department of Public
Health & Environment. The plan shall include at a minimum, the following:
1) A list of wastes which are expected to be generated on site (this should
include expected volumes and types of waste generated).
2) A list of the type and volume of chemicals expected to be stored on site.
3) The waste handler and facility where the waste will be disposed (including
the facility name, address, and phone number).
We recommend that the following requirements be incorporated into the permit as
conditions that must be met prior to issuance of building permits:
1. A stormwater discharge permit may be required for a
development/redevelopment/construction site where a contiguous or non-
contiguous land disturbance is greater than or equal to one acre in area. Contact
the Water Quality Control Division of the Colorado Department of Public Health
and Environment at www.cdphe.state.co.us/wq/PermitsUnit for more information.
We recommend that the following requirements be incorporated into the permit as
conditions that must be met prior to operation:
1. An individual sewage disposal system is required (a vault system with a
handwash station is an option) and shall be installed according to the Weld
County Individual Sewage Disposal Regulations.
2. The septic system is required to be designed by a Colorado Registered
Professional Engineer according to the Weld County Individual Sewage Disposal
Regulations.
We recommend that the following requirements be incorporated into the permit as
development standards:
1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and
Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for
final disposal in a manner that protects against surface and groundwater
contamination.
2. No permanent disposal of wastes shall be permitted at this site. This is not
meant to include those wastes specifically excluded from the definition of a solid
waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S.,
as amended.
3. Waste materials shall be handled, stored, and disposed in a manner that controls
fugitive dust, fugitive particulate emissions, blowing debris, and other potential
nuisance conditions.
4. The applicant shall operate in accordance with the approved "waste handling
plan".
2
5. Fugitive dust and fugitive particulate emissions shall be controlled on this site.
The facility shall be operated in accordance with the approved dust abatement
plan at all times.
6. This facility shall adhere to the maximum permissible noise levels allowed in the
Commercial Zone as delineated in 25-12-103 C.R.S., as amended.
7. Adequate handwashing and toilet facilities shall be provided for employees. A
conventional septic system or a permanent vaulted restroom facility (similar to a
rest area or park service) shall be provided for employees.
8. North Weld County Water District is able and intends to provide water service to
the site.
9. If applicable, the applicant shall obtain a stormwater discharge permit from the
Colorado Department of Public Health & Environment, Water Quality Control
Division.
10.The operation shall comply with all applicable rules and regulations of the State
and Federal agencies and the Weld County Code.
3
a DEPARTMENT OF BUILDING INSPECTION
Weld County Administrative Offices
918 10th Street, Greeley, CO 80631
I WEBSITE: www.co.weld.co.us
Phone(970) 353-6100, Ext. 3540
Ville,llI Fax(970) 304-6498
COLORADO
February 23, 2005
Union Pacific Railroad Company
USR-1501
Site Specific Development Plan and Special Review Permit for a Railroad car loading for recyclable materials from
Andersen's Salvage yard.
1. A building permit shall be obtained prior to the construction of any new building.
2. A plan review is required for each building for which a building permit is required. Plans shall include a floor plan.
Plans shall bear the wet stamp of a Colorado registered architect or engineer. Two complete sets of plans are
required when applying for each permit. Include a Code Analysis Data sheet provided by the Weld County Building
impartment with each Building permit application.
3. Buildings shall conform to the requirements of the various codes adopted at the time of permit application.
Currently the following has been adopted by Weld County: 2003 International Building Code; 2003 International
Mechanical Code; 2003 International Plumbing Code; 2003 International Fuel Gas Code; and the 2002 National
Electrical Code and Chapter 29 of the Weld County Code.
4.The Future vehicle storage building will be classified as S-2 occupancy. Hazardous materials shall not exceed the
amounts in table 307.7(1). Contact Eaton Fire Protection District, for their requirements. Fire resistance of walls and
openings, construction requirements, maximum building height and allowable areas will be reviewed at the plan
review. Setback and offset distances shall be determined by the Zoning Ordinance.
5. Building height shall be measured in accordance with the 2003 International Building Code for the purpose of
determining the maximum building size and height for various uses and types of construction and to determine
compliance with the Bulk Requirements from Chapter 27 of the Weld County Code. Building height shall be
measured in accordance with Chapter 23 of the Weld County Code in order to determine compliance with offset and
setback requirements. Offset and setback requirements are measured to the farthest projection from the building.
Please contact me for any further information regarding this project.eer
Siely,
R igil
Building Official
Service,Teamwork,Integrity,Quality
•
Weld County Referral
D E " E O V D January 31, 2005
FEB 2 2005
COLORADO WELD COUNTY PUBLIC WORKS DEPT
The Weld County Department of Planning Services has received the following item for review:
Applicant Union Pacific Railroad Case Number USR-1501
Please Reply By February 28, 2005 Planner Sheri Lockman
Project A Site Specific Development Plan and Special Review Permit for a business
permitted as a use by right or an accessory use in the Industrial Zone District
(Railroad car loading area for recyclable materials from Anderson's Salvage Yard)
in the A (Agricultural)Zone District
Legal Part of the E2 of Section 29, T6N, R65W of the 6th P.M., Weld County, Colorado.
Location 1/2 mile north of O Street(CR 64), east of CR 39 '/2 and west of CR 41.
Parcel Number 0803 29 000081
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
Weld County Planning Commission Hearing (if applicable) April 5, 2005
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
❑ We have reviewed the request and find no conflicts with our interests.
ASee attached letter.
Comments•
Signature ���"�SEC ���(f� Date r d—
Agency - � /� � ,t4-74-
+Weld County Planning Dept. +918 10"Street, Greeley,CO. 80631 t(970)353-6100 ext.3540 ❖(970)304-6498 fax
Weld County Planning Department
GREELEY OFFICE
rit SEP 15 2005
MEMORANDUM RECEIVED
III ' TO: Sheri Lockman, Planner II DATE: August 14, 2005 DFROM: Donald Carroll, Engineering Administrator kfli
•
COLORADO SUBJECT: USR-1501 , Union Pacific Railroad
Pickett Engineering has submitted a revised drainage report.
The Weld County Public Works has reviewed this and finds it acceptable.
pc: USR-1501 M:\PLANNING - DEVELOPMENT REVIEW\USR-Use by Special Review\USR-1501-C.doc
Weld County Planning Department
r,r OFFICE
ITB 1 tl 2005
MEMORANDUNPE �
TO: Sheri Lockman, Planner II DATE: February 15, 2005
C� FROM: Donald Carroll, Engineering Administrator
COLORADO SUBJECT: USR-1501, Union Pacific Railroad
The Weld County Public Works Department has reviewed this proposal; this project falls primarily
under the purview of the Use by Special Review Standards, Weld County Code, Chapter 23, Article II,
Division 4, Section 23. Our comments and requirements are as follows:
COMMENTS:
WCR 3912 is designated on the Weld County Road Classification Plan (FHU) as a paved road, which
requires a 60-foot right-of-way at full build out. There is presently a 60-foot right-of-way. The road is
maintained by Weld County. This road is located north of WCR 64 ("O" Street) and serves industrial
and commercial uses.
REQUIREMENTS:
Access Approach and Internal Road System: The applicant indicated that crushed concrete shall
be placed on the access and the internal road system throughout the stockpile/loading area including
the 50-foot turnaround cul-de-sac. We are agreeable to this proposal; however, if there are dust
complaints in using crushed concrete, a dust abatement alternate should be in place.
Storm Water Drainage: The applicant's drainage engineer, Picket Engineering, has provided a
drainage study for the site. Peter Schei, Weld County Public Works, has reviewed this study. The
sedimentation basin and storm water filter system will be installed with an outlet type daylighting to an
open channel to the Eaton Draw Drainage System.
Peter Schei has waived any storm water retention requirement as the proposed treatment facility shall
be adequate.
Off-Street Loading: The off-street loading spaces shall be surfaced with gravel, asphalt, or concrete
and shall be graded to prevent drainage problems. Each space should be equipped with wheel guards
where necessary to prevent vehicles from extending beyond the boundaries of the space and from
coming into contact with other vehicles, walls, fences, or plantings.
Access Width: The access width requirement for emergency equipment (fire department) is usually
20 feet. The applicant should verify and provide Public Works with the local fire department/
emergency services that the width of the access and lane is adequate for emergency response
purposes. .
M:\PLANNING-DEVELOPMENT REVIEW\USR-Use by Special Review\USR-1501DOC
Weld County Planning Department
^FFI_F( OFFICE
4 `EE v 2p05
Weld County RefgkragIVED
WIIDe.
January 31, 2005 I D
COLORADO
The Weld County Department of Planning Services has received the following item for review:
Applicant Union Pacific Railroad Case Number USR-1501
Please Reply By February 28, 2005 Planner Sheri Lockman
Project A Site Specific Development Plan and Special Review Permit for a business
permitted as a use by right or an accessory use in the Industrial Zone District
(Railroad car loading area for recyclable materials from Anderson's Salvage Yard)
in the A(Agricultural)Zone District
Legal Part of the E2 of Section 29, T6N, R65W of the 6th P.M., Weld County, Colorado.
Location 1/2 mile north of 0 Street (CR 64), east of CR 39 Yz and west of CR 41.
Parcel Number 0803 29 000081
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
Weld County Planning Commission Hearing (if applicable) April 5, 2005
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
❑ We have reviewed the request and find no conflicts with our interests.
❑ See attached letter.
Comments:
Signature Date - b<j
Agency W G O \)
❖Weld County Planning Dept. ❖918 10th Street, Greeley, CO.80631 +(970)353-6100 ext.3540 ❖(970)304-6498 fax
Applicant: Ur „on Pacific RailroaJ
Planner: Sheri Lockman Case#: USR-1501
/
,
__ pi ,
____ y c
_ . WCR 9912
1 1 51
1
1
It
II
\ 7
I
•
0.4 0 0.4 0.8 Miles
7
Weld County Referral Map N
\ / Highways
Major Roads
NLocal Roads /
At/ Railroads W E
, /0/\,,/ Streams 8 Ditches
Lakes S
Floodplains
in ` � - ._
a)E � �
E / I
O . . _ _ EWI f
C 2 ,
g @ c
o
U / 2c
§ � � . .__ . � \
in � �2 §
\ 2 $ Co_
/ 2 / $ G o \ %
Z' » » 2 w
\ c 8 o /
o m R cn R
®U E13 >, §
X22722 CoE
733
U= .ca.� 0 a
m < 7 n./ /
p .:Cr. _ \ f
. CI a Q c « p
a
E / E \ 2 2 2 0
C o co .�2) .
» w U c7) (7) � —
/ / 2 . CA f /
(lb c \ / § 2
an .E § c %
>, o % � 2 2 � �
+ c .a.2 a) w
_ .. _ -O _
m . m «
C a a 2 C o
o . ° ° ' °
a) w $ § �E
f % En g o
_, / % f o
r — ®
u) 2
0 - / f 2
CO -O 5 > 2 S /
I- C $ 2 o) a) a) o /
'01 _- / / % — [ o g
X c '6 o m
co 0 (
O M m E 2 / 2
.- E @ m C o §
0 0 co
U
- \ �c % a)
E_ \ / il / 0 o
U) E . .� § .$ k /
/
i ' m ° 0 / o
CD 03 E z 6
— Cl,
E
C E c § 0 \ 0 /
Z „ 0 — R O 6 _ « c _
$ � ° � ` f0 2
a
k \ I/ k /
U � m 11w 2
Weld County Referral
IWeld Cr n..r".rent January 31, 2005
C . ),,„_
•
COLORADO LL , =
The Weld County Department of Planning Services has received the following item for review:
Applicant Union Pacific Railroad Case Number USR-1501
Please Reply By February 28, 2005 Planner Sheri Lockman
Project A Site Specific Development Plan and Special Review Permit for a business
permitted as a use by right or an accessory use in the Industrial Zone District
(Railroad car loading area for recyclable materials from Anderson's Salvage Yard)
in the A (Agricultural)Zone District
Legal Part of the E2 of Section 29, T6N, R65W of the 6th P.M., Weld County, Colorado.
Location %mile north of O Street(CR 64), east of CR 39 Yz and west of CR 41.
Parcel Number 0803 29 000081
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
Weld County Planning Commission Hearing (if applicable) April 5, 2005
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
❑ We have reviewed the request and find no conflicts with our interests.
• See attached letter.
Comments:
7
Signature ('2 t Date _f q , 71 C,
Agency fn1nv� Frr ote(4/c, IJi tit 1rI
:Weld County Planning Dept. :•918 10"Street, Greeley,CO.80631 t(970)353-6100 ext.3540 ❖(970)304-6498 fax
EATON FIRE PROTECTION DISTRICT
50 SOUTH MAPLE AVENUE, EATON COLORADO 80615
970- 1st-2115
FAX 970- 151-216 I
FIRE PREVENTION BUREAU
Weld County Planning Department
July 7, 2005 GREELEY OFFICE
Weld County Department of Planning JUL 1 8 .2005
Ann: Sheri DoclStreet
RECEIVED
918 Tenth Street
Greeley, CO. 80631
RE: Case number USR-1501
Dear Sheri:
The Eaton Fire Protection District, Fire Prevention Bureau has met with Mike Hein of
Picket engineering. As per our meeting on July 7th 2005, the Eaton Fire Protection District
has agreed to remove all of the fire hydrant requirements that were stated in our letter
dated March 9'" 2005. The remaining requirements are:
• In accordance with the Uniform Fire Code (UFC, 1997 Edition), approved
numbers or addresses shall be provided for all new and existing buildings in such a
position as to be plainly visible and legible from the street or road fronting the
property.
• In accordance with the Uniform Fire Code (UFC, 1997 Edition), access roads shall
have an unobstructed width of not less than 20 feet and an unobstructed vertical
clearance of not less than 13 feet 6 inches.
Thank you and if you have concerns or questions, please feel free to call me at (970) 454-
2115.
Sjneeely,
Fire er Dan Santillanes
Eaton Fire Protection District Fire Prevention Bureau
EATON FIRE PROTECTION DISTRICT
50 SOUTH MAPLE AVENUE, EATON COLORADO 80615
970-454.2115
FAX 970-454-2164
FIRE PREVENTION BUREAU
March 9, 2005
Weld County Planning Department
C/o Sheri Lockman
918 Tenth Street
Greeley, CO 80631
RE: Case number USR-1501
Dear Sheri:
The Eaton Fire Protection District, Fire Prevention Bureau will require the following:
General Requirements:
• A final engineered drawing of all proposed buildings shall be submitted to the
Eaton Fire Protection District for final approval.
• A fire hydrant must be located within 150 feet of all structures and spaced within
300 feet of existing hydrants.
• Contact Eaton Fire Protection District regarding make/model, proposed locations,
and other related specifications of fire hydrants.
• Required fire flow will be calculated upon submittal of building plans. Required
flow is dependant on the types of construction and occupancy uses.
• In accordance with the Uniform Fire Code (UFC, 1997 Edition), approved
numbers or addresses shall be provided for all new and existing buildings in such a
position as to be plainly visible and legible from the street or road fronting the
property.
• In accordance with the Uniform Fire Code (UFC, 1997 Edition), access roads
shall have an unobstructed width of not less than 20 feet and an unobstructed
vertical clearance of not less than 13 feet 6 inches.
I have also sent a copy of this letter to both Gregg A. Larson of UPR, and Pickett
Engineering. Thank you and if you have concerns or questions, please feel free to call me
at (970) 454-2115.
Sinc- reiY, J /?
/
1+4
- Firefighter Dan Santillanes
Eaton Fire Protection District Fire Prevention Bureau
Hello