Loading...
HomeMy WebLinkAbout20051668.tiff star.' COLORADO SITE PLAN REVIEW Administrative Review Case Number Site Plan Review 385 (SPR-385) Parcel Number: 1313 08 102003 Applicant: GALT Properties, LLC Legal Description: Lot 3, Block 2 of Corrected Vista Commercial Filing 1; Part of the N2 of Section 8, Township 2 North, Range 68 West of the 6th P.M. Weld County, CO Zoning: PUD: C-3 (Business Commercial) & I-1 (Industrial) Uses Proposed Use: Electronic design support and test laboratory with supporting offices. Comments Meets the Intent of the Weld County Code Site Plan Certification Included in Application YES Retention Facilities Approved per referral from the Department of Public Works YES Engineering Dept.Approval dated April 22,2005 Date Offstreet Parking YES Loading Areas YES Access YES Setback Requirements 25 Feet YES Offset Requirements 10 Feet YES Landscaping YES Trash Collection and See referral from Mountain View Fire Protection District NO Storage received April 15,2005 Potable Water Left Hand Water District YES Sewage Disposal Saint Vrain Sanitation District YES Environment Standards YES Property Maintenance YES This Site P/an Review is approved with the attached conditions: The Site Plan Review Plat shall be prepared per Section 23-2-160.V of the Weld County Code. The applicant shall submit a paper copy of the plat for preliminary approval to the Weld County Department of Planning Services. Upon approval of the paper copy the applicant shall submit a Mylar plat along with all other documentation required as Conditions of Approval. The Mylar plat shall be recorded in the office of the Weld County Clerk and Recorder by Department of Planning Services' Staff within 30 days of approval and with payment of eleven ($11.00) dollars per sheet. (Department of Planning Services) 2005-1668 SPR-385 GALT Properties,LLC 1 PLU80 1. Prior to recording the Site Plan Review plat, the applicant shall address the following: A. The applicant shall attempt to address the requirements (concerns) of the Mountain View Fire Protection District, as stated in the referral response received April 15, 2005. The applicant shall specifically address the setback of the proposed dumpster from the building. Evidence of such shall be submitted in writing to the Weld County Department of Planning Services. (Department of Planning Services) The applicant shall submit a waste handling plan, for approval, to the Environmental Health Services Division of the Weld County Department of Public Health & Environment. The plan shall include at a minimum, the following: 1) A list of wastes which are expected to be generated on site (this should include expected volumes and types of waste generated). 2) A list of the type and volume of chemicals expected to be stored on site. 3) The waste handler and facility where the waste will be disposed (including the facility name, address, and phone number). Written evidence of Health Department approval shall be submitted to the Department of Planning Services. (Department of Public Health & Environment) C. The applicant shall address the requirements/concerns outlined in the referral dated April 11, 2005 from the Department of Planning Services. Written evidence of such shall be submitted to the Department of Planning Services. (Department of Planning Services) D. The applicant shall complete all proposed improvements including those regarding landscaping, screening, access improvements and parking lot requirements or enter into an Improvements Agreement according to policy regarding collateral for improvements and post adequate collateral for all required materials. The agreement and form of collateral shall be reviewed by County Staff and accepted by the Board of County Commissioners prior to recording the SPR plat. (Department of Planning Services) 2. The plat shall be amended to delineate the following: A. The requirements of the American Disability Act (ADA). ADA parking spaces are twenty (20) feet by eight (8) feet with five (5) foot aisles. A minimum of one space must be van accessible with an eight (8) foot aisle. An accessible path shall be required from the building to the public right-of-way (Dehning Way & Vista View Drive). Grading shall not be greater than 2% for the handicap stalls and access aisles. The dimensions of the handicapped parking space shall be indicated on the plat. Further, the ramps from the parking area shall be indicated. This shall be delineated on the Site Plan Review plat (Sheet 1 of 1 and the Landscape Plan sheet L-1). (Departments of Planning Services, Public Works) SPR-385 GALT Properties,LLC 2 B. The applicant shall delineate the location of all curb stops in the parking areas per Section 23-4-30.D of the Weld County Code. This shall be delineated on the Site Plan Review plat. (Department of Planning Services) C. The proposed monument sign as shown on the Site Plan Review map is 28.5 square feet in size. Section 26-2-90.D.3.f of the Weld County Code requires that monument signs be no larger than 25 square feet in size. The sign shall be revised to comply with this requirement. (Department of Planning Services) D. Section 26-2-70.c.5 of the Weld County Code states: "Loading, service or storage areas must be screened with an opaque screen that is an integral part of the building architecture. Chainlink fencing with slats or pallets is not an acceptable screening material. Plant material shall be used to soften the appearance of the screen." The applicant shall address the screening of the loading area indicated on the east side of the proposed building. (Department of Planning Services) E. Section 26-2-70 addresses the Landscape regulations. Section 26-2-70.6 addresses the landscape criteria for all property and development within the MUD area. Section 26-2-70.B.1 states landscapes shall utilize the following principles: (a) well-planned and approved planting schemes; (b) appropriate selection of drought-tolerant turf species to minimize water needs and the use of water-hungry species of turf; (c) mulch to reduce evaporation; (d) zone plant groupings according to their microclimatic needs and water requirements; (e) improvement of the soil with organic matter if needed; (f) efficient irrigation design; and (g) proper maintenance and irrigation scheduling. Sections 26-2- 70.B.2 through Section 26-2-70.B.7 specifically addresses the criteria to be utilized in the preparation of the Landscape plan. The Landscape Plan, shall at a minimum, delineate: 1. The applicant shall include in the Landscape Plan in accordance with Section 23-3-250.A.5, the following information: A. The installation schedule that specifies when the landscaping will be installed on site. (Department of Planning Services) B. A landscape maintenance schedule which specifically states who will perform maintenance and that maintenance is on-going and shall not end upon final acceptance by the Department of Planning Services. (Department of Planning Services) C. The method of native grass planting shall be called out as drilled or broadcast and applied at a rate of how many pounds per acre, and/or pounds per square foot. (Department of Planning Services) 2. Section 26-2-70.C addresses the landscape requirements for parking lots. The following criteria shall be met for this application and indicated on the landscape plan: SPR-385 GALT Properties,LLC 3 A. A minimum of ten percent (10%) of the area of a parking lot must be landscaped if the lot contains ten (10) or more spaces. The requirement may be counted toward the maximum lot coverage requirement of each zone district. At least seventy-five percent (75%) of the required landscape area shall include living plant material. (Department of Planning Services) B. Berming and shrub or tree planting shall be used to screen parking lots from view of the roadway. Berms can vary in height depending on location and proximity of existing trees. Berms shall have smooth transitions from the top of the curb to the setback line so as to not create snow traps, with allowances made for placement of the sidewalk. Grading of berms shall not be lumpy or abrupt. Berm cross-sections shall be indicated on the landscape plan. See Appendix 26-H of the Weld County Code. At least 75% of the length of the frontage of the parking lot must be screened. The parking lot area includes the designated parking area along with the driveway that circles around the building to the west, south and east. (Department of Planning Services) C. Deciduous trees shall be 2.5 inch caliper in size as required per Section 26-2-70 2.b of the Weld County Code and shall be indicated as such on the landscape plan. (Department of Planning Services) F. Section 26-2-90.f of the Weld County Code States: "Monument signs shall be on premises signs, the sign area shall not exceed twenty-five (25) square feet..." Your proposed monument sign (including the sign base) exceeds twenty-five (25) square feet in area. The proposed sign shall be redesigned to meet maximum sign area requirements. Note that section 26-2-90.f also states: "An enclosed or solid sign base shall not be required if the lower edge of the sign face is no higher than one (1) foot above the finished grade". The sign will meet sign size requirements if the base is removed. 3. The following notes shall be placed on the plat: A. In accordance with the Weld County Code, no land, building or structure shall be changed in use or type of occupancy, developed, erected, constructed, reconstructed, moved or structurally altered or operated in the Commercial Zone District until a Site Plan Review has been approved by the Department of Planning Services. (Department of Planning Services) B. The application does not propose any portion of the site to be leased to another party. In the event that a portion of the building is proposed to be leased to another party in the future, the applicant shall submit a copy of the lease agreement and information regarding the proposed use of the leased portion to the Weld County Attorney's office, Weld County Building Inspection Department, Mountain View Fire Protection District and the Department of Planning Services for review. Based upon the proposed use and/or impacts of the leased portion, SPR-385 GALT Properties,LLC 4 the Department of Planning Services may require a new Site Plan Review application. (Department of Planning Services) C. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100, C.R.S., as amended), shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. (Department of Public Health and Environment) D. No permanent disposal of wastes shall be permitted at this site. This is not meant to include those wastes specifically excluded from the definition of a solid waste in the Solid wastes Disposal Sites and Facilities Act, .30-20-100.5,C.R.S., as amended. (Department of Public Health and Environment) E. The applicant shall operate in accordance with the approved "waste handling plan". (Department of Public Health and Environment) F. Waste materials shall be handled, stored and disposed of in a manner that controls fugitive dust, blowing debris and other potential nuisance conditions. (Department of Public Health and Environment) G. The facility shall adhere to the maximum permissible noise levels allowed in the Commercial Zone District, as delineated in 25-12-103, Colorado Revised Statutes, as amended. (Department of Public Health and Environment) H. Fugitive dust and fugitive particulate emissions shall be controlled on this site. (Department of Public Health and Environment) The facility shall utilize the St. Vrain Sanitation District for sanitary sewage treatment and disposal. (Department of Public Health and Environment) J. The facility shall obtain water service from the Left Hand Water District. (Department of Public Health and Environment) K. Landscaping materials as indicated in the approved Landscape Plan shall be maintained at all times. Dead or diseased plant materials shall be replaced with materials of similar quantity and quality at the earliest possible time. (Department of Planning Services) L. All potentially hazardous chemicals must be stored and handled in a safe manner in accordance with the product labeling and in a manner that minimizes the release of hazardous air pollutants (HAPs) and volatile organic compounds (VOCs). (Department of Public Health and Environment) M. The operation shall comply with all applicable rules and regulations of the Federal Communications Commission (FCC) and the Code of Federal Regulation (CFR). (Department of Public Health and Environment) N. If applicable, the applicant shall obtain a stormwater discharge permit from the Colorado Department of Public Health & Environment, Water Quality Control Division. (Department of Public Health and Environment) SPR-385 GALT Properties,LLC 5 O. The operation shall comply with all applicable rules and regulations of the State and Federal agencies and the Weld County Code. (Department of Public Health and Environment) P. All structures, including signs, on site must obtain the appropriate building permits. (Department of Planning Services) Q. Effective January 1, 2003, Building Permits will be required to adhere to the fee structure of the Weld County Road Impact Program. (Ordinance 2002-11) (Department of Planning Services) R. Exterior illumination of structures and lots shall be restricted as follows: 1) Sources of light shall be shielded so that beams of light will not shine directly onto adjacent properties. 2) Neither the direct nor reflected light from any light source may create a traffic hazard to operators of motor vehicles on public or private streets. S. Prior to the issuance of each building permit: 1) The Architectural Control Committee shall provide a letter to the Department of Planning Services indicating its approval of the proposed structure. 2) The applicant shall submit evidence to the Department of Planning Services that the proposed fire protection system will meet the standards of the Mountain View Fire Protection District. Prior to the issuance of any building permits on any lot, adequate evidence shall be submitted to the Department of Planning Services that the proposed fire protection system will meet the standards of the Mountain View Fire Protection District. T. Buildings shall conform to the requirements of the various codes adopted at the time of permit application. Currently, the following has been adopted by Weld County: 2003 International Building Code; 2003 International Mechanical Code; 2003 International Plumbing Code, 2003 International Fuel Gas Code, 2002 National Electrical Code and Chapter 29 of the Weld County Code. (Department of Building Inspection) U. The building, parking areas and assess routes shall conform to the American with Disabilities Act and CABO/ANSI A117.1-1992. (Department of Building Inspection) V. Maximum allowed building height, protection of walls and openings and the separation of buildings of mixed occupancy shall be in accordance with Chapter 29 of the Weld County Code. Setback and offset distances shall be determined by Chapter 23 of the Weld County Code. (Department of Building Inspection) W. Building height shall be measured in accordance with the 2003 International Building Code for the purpose of determining the maximum building size and height for various uses and types of construction and to determine compliance with the Bulk Requirements from Chapter 27 of the Weld County Code. Building height shall be measured in accordance with Chapter 23 of the Weld County Code in order to determine compliance with offset and setback requirements. SPR-385 GALT Properties,LLC 6 Offset and setback requirements are measured to the farthest projection from the building. (Department of Building Inspection) X. Property Maintenance. Property located within Commercial Zone Districts shall be maintained in such a manner that grasses and weeds are not permitted to grow taller than twelve (12) inches. In no event shall the property owners allow the growth of noxious weeds. (Weld County Codification Ordinance 2000-1) (Department of Planning Services) Y. There shall be no staging or parking of vehicles on Vista View Drive. Utilize on- site parking only. (Department of Public Works) Z. This replat shall comply with the notes listed on the Vista Commercial Center Filing I plat (S-608) recorded 7/29/1997 under reception #2560213. (Department of Planning Services) 4. Prior to the release of building permits: A. A Final Site Plan and building construction plans must be submitted to the Mountain View Fire Protection District for review and approval. The applicant shall submit written evidence of approval to the Department of Building Inspection. (Mountain View Fire Protection District) B. Upon approval by the Department of Planning Services, the Site Plan Review plat shall be prepared per Section 23-2-160.W of the Weld County Code and submitted to the Department of Planning Services to be recorded. (Department of Planning Services) C. Written evidence from the Architectural Control Committee indicating its approval of the proposed buildings shall be submitted to the Departments of Planning Services and Building Inspection. (Department of Planning Services) D. Building permits shall be obtained prior to the construction of the buildings. A plan review is required for each permit. Plans shall include a floor plan and bear the wet stamp of a Colorado registered architect or engineer. Two complete sets of plans are required when applying for the permit. A Code Analysis Data sheet provided by the Weld County Building Department shall be submitted with each Building permit application. (Department of Building Inspection) E. The buildings will require an engineered foundation based on a site-specific geotechnical report or an open hole inspection performed by a Colorado registered engineer. Engineered foundations shall be designed by a Colorado registered engineer. (Department of Building Inspection) F. Effective January 1, 2003, Building Permits issued on the proposed lots will be required to adhere to the fee structure of the Weld County Road Impact Program. (Ordinance 2002-11) (Department of Planning Services) 5. Prior to Certificate of Occupancy: SPR-385 GALT Properties,LLC 7 A. The applicant shall provide written evidence to the Department of Building from the Left Hand Water District that all requirements from the District's letter dated November 18, 2003 have been addressed and water service has been obtained. (Left Hand Water District) B. The applicant shall provide written evidence from the St. Vrain Sanitation District to the Department of Building Inspection that all requirements from the District's letter dated November 19, 2003 have been addressed and sewer service has been obtained. (St. Vrain Sanitation District) C. A final inspection of occupancy will be required by a member of the Mountain View Fire Protection District before a Certificate of Occupancy is issued from Weld County. (Mountain View Fire Protection District) 6. A. A stormwater discharge permit may be required for a development/redevelopment/construction site where a contiguous on noncontiguous land disturbance is greater than or equal to one acre in area. The applicant shall inquire with the Water Quality Control Division (WQCD) of the Colorado Department of Public Health and Environment at www.cdphe.state.co.us/wq/PermitsUnit if they are required to obtain a stormwater discharge permit. Alternately, the applicant can provide evidence from the WQCD that they are not subject to these requirements. (Department of Public Health and Environment)NSite Plan Review conditionally approved by: Date: Chris Gathman, Planner 11-AICP SPR-385 GALT Properties,LLC 8 Q DEPARTMENT OF PLANNING SERVICES NORTH OFFICE 918 10TH Street GREELEY, CO 8063 80631 PHONE: (970) 353-61O0, Ext. 3540 WI FAX: (970) 304-6498 I D UTHWEST OFFICE cis 4 209 CR 24.5 LOONGMONT, CO 80504 COLORADO PHONE: (720) 652-4210, Ext. 8730 FAX: (720) 652-4211 March 28, 2005 Galt Properties PO Box 2071 Longmont CO 80502 Subject: SPR-385-Site Plan Review for an electronics laboratory and offices located in the I-1 (Industrial) and C-3 (Commercial)Zoning Districts on a parcel of land described as Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Dear Applicant: Your application and related materials for the request described above are complete and in order at this time. Our Department will be processing the Site Plan within 45 to 60 days upon receipt of the application. You will be notified by this office at the end of the review period regarding the site plan. It is the policy of Weld County to refer an application of this nature to any town or municipality lying within three miles of the property in question or if the property under consideration is located within the comprehensive planning area of a town or municipality. Therefore,our office has forwarded a copy of the submitted materials to the Firestone and Longmont Planning Commission for their review and comments. It is recommended that you and/or a representative be in attendance at the Firestone and Longmont Planning Commission meeting to answer any questions the Commission members may have with respect to your application. Please call Firestone at 303-833-3291 and Longmont at 303-651-8601, for further details regarding the date, time, and place of the meeting. If you have any questions concerning this matter, please feel free to call or visit our office. Sincerely, Chris Gathman Planner SITE PLAN REVIEW (SPR) APPLICATION FOR PLANNING DEPARTMENT USE DATE RECEIVED: ------------------ RECEIPT it/AMOUNT t! __ ;S __ _ CASE N ASSIGNED:____ _ APPLICATION RECEIVED BY— —__— — — PLANNER ASSIGNED _----_—__— Parcel Number 1 3 1 3 . 0 8 . 1 _ 0 2 . 0 0 3 (12 digit number-found on Tax I.D.information.obtainable at the Weld County Assessors Office.or www.co.weld.00.us). Legal Description Vista Comm Ctr F1 Corr, L3_62_ Section 08. Township_2 North, Range 68West Lot/Block:_-3 /_Blk 2 zone District: -1, C-3 . Total Acreage:_1_37—__ Overlay District:_____ _ FEE OW NER(S) OF THE PROPERTY: Name: Galt Properties LLC_-_-_- Work Phone uL303)931-7815-iome Phone VL0)931-7815E mailAddre s_Iho; t ci.cZv,4tj^j'Cot" Address: PO Box 2071 K; nisn City/State/4 Code=fin gnt. GO 84542 ------------_—_-- —-- --- Name: Work Phone it _ _Home Phone 1/ __ _______Email Address_ __-- — Address: City/State/Zip Code _— _—_—_--___—_—__—_—_—_—_------ —_ Name: __ ____ _____ _____ Work Phone N - Home Phone p _ _— Address:City/State/Zip Code— — __- — ----_--__ — _ __—_ ___ ___ APPLICANT OR AUTHORIZED AGENT(See Below:Authorization must a company application straw!by Autlouized Ayenti Name: __ —_ W ork Phone 41 - Horne Phone N_ Email Address Address: City/State/Zip Code___ PROPOSED USE: Electronics laboratop/ and offices — — — I(We)hereby depose and We under penakies of perjury the t all statem ents.proposals.a ndior plans subm it led with or contained within ff a application are true and correct le the best of my (our)knowledge. Signatures of all fee owners of property must sign this applicafion. If an Authorized Agent signs-a letter of authorization from all fee owners must be included with the application.If a corporation is the fee owner, notarized evidence must be included showing the signatory has to legal authority to sign for the corporation. Signature'Owner or Authorized Agent Date Signature: 0w r Authorized Agent ate 1435 WEST 29"" STREET LOVELAND, CO B053B �M ' (970) 461 -2661 CIVIL ENGINEERS ' • FAX (970) 461 -2665 WWW.DMWCIVILENGINEERS.COM To: Weld County Department of Planning Services 4209 Weld County Road 24% Longmont, CO 80504 From: Jade P. Miller, P.E. DMW Civil Engineers, Inc. Date: March 18, 2005 Project: Site Plan Review Application Lot 3, Block 2, Corrected Vista Commercial Center Filing No. 1 Galt Properties, LLC DMW Project No. 0216.00-GLT On behalf of our client with the above referenced project, DMW is pleased to submit this Site Plan Review Application. The items listed below are included as part of this submittal in accordance with Section 23-2-160 of the Weld County Code. If you have any questions or concerns regarding this Application, please do not hesitate to contact me. 23-2-160.A One(1)original and fourteen(14)copies of the Site Plan Review Application • are included along with one (1) original and fourteen (14) copies of the Site Plan Review Certification and one (1) original and one (1) copy of the Emergency Information Sheet. ++ 23-2-160.6 Fifteen (15) copies of the deed or legal instrument are provided. tt 23-2-160.C NA - Not a duplex 23-2-160.D NA - Not a condo 23-2-160.E Description of Proposed Use: The proposed use for the above referenced property is an electronic design support and test laboratory with supporting offices. The building will house approximately 2,694 square feet of office space and 7,937 square feet of laboratory area. Paved parking areas will be provided adjacent to the building for clients and approximately 6 employees. 23-2-160.F One (1) original and fourteen (14) copies of a letter from the Left Hand Water District are provided to demonstrate that water service is available. 23-2-160.G One (1) original and fourteen (14) copies of a letter from the St. Vrain Sanitation District are provided to demonstrate that sewer service is available. 23-2-160.H One (1) original and fourteen (14) copies of the County Road Access Information Sheet are provided. 23-2-160.1 The Description of Proposed USE states that there will be approximately six (6) employees. 23-2-160.J The Zone Districts for the above referenced property are I-1 and C-3. No USE or ACCESSORY USE has been located closer than twenty-five (25) feet from the right-of-way in accordance with the performance standards for both the Commercial and Industrial Zone Districts. No USE or ACCESSORY USE has been located closer than ten (10) feet from the LOT line in accordance with the performance standards for both the Commercial and Industrial Zone Districts. 23-2-160.K Fifteen (15) copies of the Building Elevations are provided. 23-2-160.L A detail for proposed signage along with its position are provided on the Site Plan Review Map. 23-2-160.M Fifteen (15) copies of the Landscape Plan are provided. 23-2-160.N One(1)original and fourteen (14) copies of the Stormwater runoff statement are provided. 23-2-160.O The site meets the Off-Street Parking Requirements listed in Article IV, Division 1 of Chapter 23 and Appendix 23-B of the Weld County Code. For office uses, one space is required for every two employees plus an additional space for each 500 square feet. With 10,631 square feet and 6 employees, the site requires 24 spaces. The site provides 24 parking spaces which includes one van-accessible space. 23-2-160.P Sufficient space has been provided to accommodate vehicles being loaded or unloaded without encroachment upon neighboring property or rights-of- way. Potential loading areas are paved and are designed to comply with the appropriate use regulations of the Weld County Code. 23-2-160.Q The above referenced lot has safe access to Vista View Drive on the north. 23-2-160.R New accesses to Vista View Drive are designed in accordance with standards required by the Weld County Department of Public Works. 23-2-160.S Acceleration and Deceleration lanes are not required nor provided for this project. 23-2-160.T Areas USED for trash collection are SCREENED from public rights-of-way and all ADJACENT properties and are designed and used in a manner that will prevent wind or animal scattered trash. 23-2-160.U This site is part of an approved Development and the USE is compatible with adjacent properties. 23-2-160.V Fifteen (15) copies of the Site Plan Review Map are provided. 23-2-160.W Site Plan Review Plat is not required for this submittal. 23-2-160.X One (1) original and fourteen (14) copies of a Statement of Taxes Due from Weld County have been provided to indicate that taxes are not delinquent for the property. 23-2-160.Y Fifteen (15) copies of Schedule B-2 (Exceptions) for the Title Commitment for the property have been provided to demonstrate Mineral Owners agreements. 23-2-160.Z NA - No irrigation ditches are present on this property. EMERGENCY CONTACT INFORMATION PLEASE TYPE OR PRINT Business Name:Galt Properties, LLC Phone: (303) 931-7815 Address: 1736 Vista View Drive, Longmont, CO 80501 Business owner:Vincent Greb Phone: c303) 931-7815 Home Address: 1798 Meadow Vale Road City: Longmont, CO 80504 List three persons in the order to be ca Ned in the event of an em ergency: NAME TITLE ADDRESS PHONE Vincent Greb Vice Pres. 1798 Meadow Vale Rd, Longmont, CO 80504 (303)931-7815 Gary Custer Consultant 1624 Juniper, Longmont, CO 80501 (303)588-7355 Business Hours: __8:00am - 4:30 pm Days: Monday= Friday Type of Ala Non Burglar Holdup Fire Silent Audible Name and address of alarm company: Location of Safe: None MISCELLANEOUS INFORMATION: Number of entrylexit doors in the buildhg: Location(s): Is alcohol stored in buildhg? No Location(s): Are drugs stored in building? No _ Location(s) Are weapons stored n buildhg? No Location(s) The followng programs are offered as a public service of the Weld County Sheriffs Office. Please indicate the programs of interest. __Physical Security Check Crime Prevenbon Presentation UTILITY SHUT OFF LOCATIONS: Main electrical: North side of building Gas shut off: North side of building Exterior water shutoff:_Valve lve at watermain in Vista View Drive Interior water shutoff: Mechanical room in north end of building 14OV ,.29, STREET LO VELAND LAN D, CO 8053B , (970) 461-2661 CIVIL ENGINEERS Fax (970) 461 -2665 WWW.D MWCIVILENS I NEER S.COM March 17, 2005 Weld County Department of Planning Services 4209 Weld County Road 241/ Longmont, CO 80504 Project: Site Plan Review Application Lot 3, Block 2, Corrected Vista Commercial Center Filing No. 1 Galt Properties DMW Project No. 0426.00-GLT I have reviewed the drainage report for the Vista Commercial Center, Filing No. 1. Vista Commercial Center, Filing No. 1 provides detention for the entire subdivision along its northern boundary adjacent to Highway 119. Individual lot owners are not required to provide detention on their properties. However, property owners are required to collect and convey their stormwater runoff to ditches adjacent to roadways and to internal lot ditches. The roadside ditch along Vista View Drive adjacent to Lot 3, Block 2, will convey the runoff to Detention Pond 4. The Final Drainage Report for Vista Commercial Center, Filing No. 1, established the runoff coefficients for the 10-year and the 100-year storms to be 0.88 and 0.89, respectively. The calculated runoff coefficients for the 10-year and the 100-year • ,' storms for Lot 3, Block 2 (1.37 acres), are 0.61 and 0.71 respectively. The 10-year and ;? 100-year peak runoff rates were calculated to be 3.3 cfs and 5.90 cfs, respectively. ft Therefore, no detention will be required for Lot 3, Block 2. The grading plan is adequate ¢' for the conveyance of the stormwater runoff to the roadside ditch along Vista View Drive "` and the driveway culverts are sized to convey necessary runoff flows. Please do not hesitate to contact me if you have any questions or concerns regarding the drainage issues for this site. Sincerely, DMW CIVIL ENGINEERS, INC. PoG REG 33885 SSid(VALa \ Jade P. Miller, P.E. (CO #33885) Project Engineer Area-Weighting for Runoff Coefficient Calculation Project Title: Galt Properties Catchment ID: All Illustration Sib°es� LEGEND: Flow Direction bodes S Catchment Saaa 3 Botaodary Instructions: For each catchment subarea,enter values for A and C. Subarea Area Runoff Product ID acres Coeff. A C* CA input input input output Roof 0.24 0.95 0.23 Walk 0.08 0.95 0.08 Pavement 0.42 0.95 0.40 Gravel 0.00 0.50 0.00 Landscape 0.62 0.20 0.12 Sum: 1.37 sum: 0.83 Area-Weighted Runoff Coefficient(sum CA/sum A)= 0.61 *See sheet"Design Info"for inperviousness-based runoff coefficient values. GLT-RAT.xls, Weighted C 03/18/2005, 11:36 AM CALCULATION OF A PEAK RUNOFF USING RATIONAL METHODil Project Title: Galt Properties Catchment ID: All I. Catchment Hydrologic Data Catchment ID= All Area= 1.37 Acres Percent Imperviousness= 75.00 % NRCS Sal Type= C A,B,C,or D II. Rainfall Information I(inch/hr)a C1•P1/(C2+Td)^C3 Design Storm Return Period,Tr= 10 years (input return period for design storm) • C1 = 28.50 (input the value of C1) C2= 10.00 (input the value of C2) C3= 0.786 (input the value of C3) P1= 1.76 inches (input one-hr precipitation—see Sheet"Design Info") III. Analysis of Flow Time(Time of Concentration)for a Catchment • Runoff Coefficient,C= 0.62 Overide Runoff Coefficient,C= (enter an overide C value if desired,or leave blank to accept calculated C.) 5-yr.Runoff Coefficient,C-5= 0.58 Overide 5-yr.Runoff Coefficient,C= (enter an overide CS value if desired,or leave blank to accept calculated C-5.) Illustration • -. overlandLIGEND Reach 1 Row Reach 2• O RogS deg • Flaw Dinettes' Reach Catchment Boundary NRCS Land Heavy Tillage/ Short Nearly Grassed Paved Areas& Type Meadow Field Pasture/ Bare Sales/ Shallow Paved Swaim _ Lawns Ground Waterways (Sheet Flow) Conveyance 2.5 5 7 10 15 20 Calculations: Reach Slope Length 5-yr NRCS Flow Flow ID S L Runoff Convey- Velocity Time Coeff ance V Tf ft/ft ft C-5 fps minutes input input output input output output Overland 0.2500 35 0.58 0.30 1.94 1 0.0080 153 20.00 1.79 1.43 2 0.0050 642 20.00 1.41 7.57 3 0.0150 250 15.00 1.84 2.27 4 5 Sum 1,080 Computed Tc= 13.20 Regional Tc= 16.00 W. Peak Runoff Prediction using Computed Tc iction using Regional Tc Rainfall Intensity at Tc,I= 4.24 inch/hr Rainfall Intensity at Tc, I= 3.87 inch/hr Peak Flowrate,Qp= 3.57 cfs Peak Flowrate,Qp= 3.27 cfs GLT-RAT.Ids,Tc and PeakO 03/18/2005,11:42 AM CALCULATION OF A PEAK RUNOFF USING RATIONAL METHOD Project Title: Galt Properties Catchment ID: All I. Catchment Hydrologic Data Catchment ID= All Area= 1.37 Acres Percent Imperviousness= 75.00 % NRCS Soil Type= C A,B,C,or D II. Rainfall Information I(inchlhr)a Cl•P1/(C2+Td)AC3 Design Storm Return Period,Tr= 100 years (input return period for design storm) C1 = 28.50 (input the value of C1) C2= 10.00 (input the value of C2) C3= 0.786 (input the value of C3) P1= 2.78 inches (input one-hr precipitation—see Sheet"Design Info") III.Analysis of Flow Time(Time of Concentration)for a Catchment Runoff Coefficient,C= 0.71 Overide Runoff Coefficient,C= (enter an overide C value if desired,or leave blank to accept calculated C.) 5-yr.Runoff Coefficient,C-5= 0.58 Overide 5-yr.Runoff Coefficient,C= (enter an overide C-5 value if desired,or leave blank to accept calculated C-5.) Illustration overland LEGEND Reach 1 Hew Reaek2• O Batbruting • Fla Direction lteael3 Catchnuat Hwdarr NRCS Land Heavy Tillage/ Short Nearly Grassed Paved Areas& Type Meadow Field Pasture/ Bare ' Swales/ Shallow Paved Swabs Lawns Ground Waterways' (Sheet Flow) Conveyance 2.5 5 7 10 i 15 - 20 Calculations: Reach Slope Length 5-yr NRCS Flow Flow ID S L Runoff Convey- Velocity Time Coati ance V Tf ft/ft ft CS fps minutes input input output input output output Overland 0.2500 35 0.58 0.30 1.94 1 0.0080 153 20.00 1.79 1.43 2 0.0050 642 20.00 1.41 7.57 3 0.0150 250 1590 1.84 2.27 4 5 Sum 1,080 Computed Tc= 13.20 Regional Tc= 16.00 IV. Peak Runoff Prediction using Computed Tc iction using Regional Tc Rainfall Intensity at Tc,I= 6.69 inch/hr Rainfall Intensity at Tc,I= 6.12 inch/hr Peak Flowrate,Op= 6.49 cfs Peak Flowrate,Qp= 5.93 cfs GLT-RAT.tds,Tc and PeakO 03/18/2005,11:45 AM Report Date: 03/16/2005 10:32AM WELD COUNTY TREASURER Page: 1 STATEMENT OF TAXES DUE SCHEDULE NO: R7043998 ASSESSED TO: HORIZON INVESTMENT LLC 1835 FAITH PL LONGMONT, CO 80501 LEGAL DESCRIPTION: VCC L3 BLK2 VISTA COMMERCIAL CENTER PARCEL: 131308102003 SITUS ADD: TAX YEAR CHARGE TAX AMOUNT INTEREST FEES PAID TOTAL DUE 2004 TAX 2,121.48 0.00 0.00 0.00 2,121.48 TOTAL TAXES 2,121.48 GRAND TOTAL DUE GOOD THROUGH 03/16/2005 2,121.48 ORIGINAL TAX BILLING FOR 2004 TAX DISTRICT 2342 - Authority Mill Levy Amount Values Actual Assessed WELD COUNTY 19.957 549.62 VACANT LAN 94,951 27,540 SCHOOL DIST RE1J 40.089 1,104.04 NCW WATER 1.000 27.54 TOTAL 94,951 27,540 SVW WATER 0.230 6.33 LEFT HAND WATER 0.000 0.00 MTN VIEW FIRE(BOND 2008) 0.290 7.99 ST VRAIN SANITATION 4.401 121.20 WELD LIBRARY 3.249 89.48 LONGMONT CONSERVATION 0.000 0.00 MOUNTAIN VIEW FIRE 7.817 215.28 TAXES FOR 2004 77.033 2,121.48 ALL TAX LIEN SALE AMOUNTS ARE SUBJECT TO CHANGE DUE TO ENDORSEMENT OF CURRENT TAXES BY THE LIENHOLDER OR TO ADVERTISING AND DISTRAINT WARRANT FEES. CHANGES MAY OCCUR AND THE TREASURER'S OFFICE WILL NEED TO BE CONTACTED PRIOR TO REMITTANCE AFTER THE FOLLOWING DATES: PERSONAL PROPERTY AND MOBILE HOMES-AUGUST 1, REAL PROPERTY-AUGUST 1. TAX LIEN SALE REDEMPTION AMOUNTS MUST BE PAID BY CASH OR CASHIERS CHECK. P.O. Box 458 Greeley, CO 80632 (970) 353-3845 ext. 3290 • • Statement of Authority (Section 38-30-172,C.R.S.) 1. This Statement of Authority relates to an entity named GALT PROPERTIES, LLC 2. The type of entity is a LIMITED LIABILITY COMPANY 3. The entity is formed under the laws of COLORADO 4.,T,he mailing address of the entity is: "rii), SOX Lo mnnl- 6) 5. The name and position of each person authorized to execute instruments conveying, encumbering, or otherwise affecting title to real property on behalf of the entity is: SHAUNA L. CUSTER MEMBER VINCENT W. GREG MEMBER 6. The authority of the foregoing person(s)to bind the entity is limited as follows: -fh)o 7. This Statement of Authority is executed on behalf of the entity pursuant to the provisions of S 38-30-172, C.R.S. 8. This Statement of Authority amends and supersedes in all respects any prior Statement of Authority executed on behalf of the entity. Executed this 16th day of MARCH , 2005 . Name: .. STER Name: —7.1.9.441,„..i-Hz...).YAMS VINCENT W. GREB STATE OF COLORADO )ss. COUNTY OF BOULDER The foregoing instrument was acknowledged before me this 16th day of MARCH 20 05 by SHAUNA L. CUSTER AND VINCENT W. GREB Witness my hand and official seal. My commission expires: .... b i�� Notary blic • SITE PLAN CERTIFICATION I(We)hereby certify that the uses, buildings. and structures located on: Lot 3Block 2LVista Commercial Center Filing 1,Corrected____ (legal description) ----------_--_--_--- are designed and will be constructed and operated in accordance with the applicable Performance Standards and District Requirements for the ___I_1, C-3 __ _ zone distrbt as stated in the Weld County Code and in accordance with any conditions imposed by the Board of County Commissioners at the time the property was zoned or rezoned. I understand my failure to comply with the performance standards anther any conditions could result in the County initiating a compliance action against me. Signature f Property Owner The foregoing instrument was subscribed and sworn to before me this_�� _ day of 1!rS� ' 20_05 by Sa,n haSd.L�ZL1_____-- WITNESS my hand and official seal. My Commission Expires 12/03/2008 ommission expire•: Notary Public REFERRAL LIST County Towns & Cities Fu a Districts _Attorney _Ault _Ault F-1 'z Health Department _Berthoud _Berthoud F-2 $$$ _Extension Office _Brighton _Briggsdale F-24 _Emergency Mgt Office - Ed Herring Dacono _Brighton F-3 _Sheriffs Office _Eaton _Eaton F-4 �z-Public Works _Erie _Fort Lupton F-5 _Housing Authority Evans _Galeton F-6 _AirportAuthority "r- Firestone _Hudson F-7 —z'-Building Inspection _Fort Lupton _Johnstown F-8 -z'Code Compliance_S.-Ann_N-Beth _Frederick _LaSalle F-9 z` Kim Ogle (Landscape Plans) _Garden City ir-Mountain View F-10 _Lin (Addressing Change of Zone) _Gilcrest _Milliken F-11 _Ambulance Services Nunn F-12 _Greeley _ _Grover _Pawnee F-22 State _Hudson _Platteville F-13 Div._ of Water Resources Johnstown _Platte Valley F-14 _Geological Survey _Keenesburg _Poudre Valley F-15 Department of Health _Kersey _Raymer F-2 N ZNDepartment of Transportation _LaSalle _Southeast Weld F-16 _Historical Society _Lochbuie _Union Colony F-20 _Water Conservation Board � z`Longmont _Wiggins F-18 _ & Gas Conservation Commission Mead _Oil Windsor/Severance F-17 _Milliken Division of Wildlife _New Raymer _South Hwy 66 (Loveland) _Northglenn _North Hwy 66 (Greeley) _Nunn _Division of Minerals/Geology _Pierce Commissioner _Platteville _ Soil Conservation Districts _Severance _Big Thompson/ FTC _Thornton X`Boulder Valley/Longmont _Windsor _Brighton/SE Weld _Centennial Counties _Greeley/West Greeley _Adams _Platte Valley r Boulder _West Adams _Broomfield _Little Thompson _Larimer Federal Government Agencies Other US Army Corps of Engrs _School District RE- _ _USDA-APHIS Vet Service _Central Colo. Water Cons _Federal Aviation Admin (Structures _RR over 200 ft or w/in 20000 ft of Pub _Ditch Airport Company, Federal Communications Comm z Art Elmquist (MUD Area) - _ Info Only Name: �r, �2S 1-/--C- Case LIST Case#: SP P . 3'8 5 County Towns&Cities Fire Districts Attorney Ault Ault F-1 X Health Department Berthoud Berthoud F-2 $$$ _Extension Office _Brighton Briggsdale F-24 _Emergency Mang Office- Ed Herring _Dacono _Brighton F-3 Sheriffs Office Eaton Eaton F-4 X(Public Works Erie Fort Lupton F-5 _Housing Authority Evans _Galeton F-6 Airport Authority )( Firestone _Hudson F-7 X Building Inspection Fort Lupton Johnstown F-8 X Code Compliance Ann X Beth Frederick LaSalle F-9 2c Kim Ogle (Landscape Plans) Garden City Mountain View F-10 _Lin (Addressing Change of Zone) _Gilcrest _Milliken F-11 Ambulance Services _Greeley _Nunn F-12 _Grover _Pawnee F-22 State Hudson _Platteville F-13 Div. of Water Resources Johnstown _Platte Valley F-14 Geological Survey _Keenesburg _Poudre Valley F-15 Department of Health _Kersey Raymer F-2 }( Department of Transportation _LaSalle _Southeast Weld F-16 _Historical Society Lochbuie Union Colony F-20 Water Conservation Board %Longmont _Wiggins F-18 Oil & Gas Conservation Commission _Mead Windsor/Severance F-17 _Milliken IJZ Division of Wildlife _New Raymer Legal (_C3,5 KZ-VtsA FIUUG I',g-?- _South Hwy 66 (Loveland) _Northglenn Parcel ID# 13)3 03 102003 (.0) _North Hwy 66 (Greeley) Nunn Zone Acres? _Division of Minerals/Geology _Pierce USDA "Dcu¢,\op&k _Platteville Airport Nit) Soil Conservation Districts Severance Geo HF No Big Thompson _Thornton FP? No Panel# _Boulder Valley _Windsor IGA? Ta,S ORD# Lodi MINT _Brighton MUD? \-(Q-5 Centennial Counties Fort Collins Adams _Greeley )( Boulder Longmont Broomfield Morgan Platte Valley _Larimer _Southeast Weld West Adams Other ilk Central Cola Water Conservancy Dist Federal Government Agencies _Left Hand Water US Army Corps of Engrs School District RE- _ USDA-APHIS Vet Service X Art Elmquist(MUD Area)- Info Only Federal Aviation Admin (Structures Ditch Company, over 200 ft or w/in 20000 ft of Pub lala Airport Commissioner Federal Communications Comm _ 41" LUCCk at. t O2- Weld County Referral COLORADO March 28, 2005 The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5. For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan XWe have reviewed the request and find no conflicts with our interests. ❑ See attached letter. r WXY) C'�v �1.L .C1`t. • 0 K` .k't\.r',: ( r CAJ Comments: 1/4,c t,1OtaEnlr} tL C Signature CC)ICI r` • r Y r Date Agency � � d� �,y, e. +Weld County Planning Dept. +918 10'"Street, Greeley, CO. 80631 •(970)353-6100 ext.3540 ÷(970)304-6498 fax RECEIVED ON V U d, kAR a 1 2005 SR- l 15 ' CDOT Region 4 Traffic Section Weld County Planning oepart4i# eld Count Referral GREELEY OFFICE COLORADO APR 2 2005 March 28, 2005 RECEIVED The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5 For a more precise location, see legal Parcel Number 1061 05 000037 T� u ris submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new 'information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. Comments: / L [ern') nu ✓v( . Signature (tar Agency (tar Atm.s S Date +Weld County Planning Dept. +918 10"Street, Greeley, CO.80631 O(970)353-6100 ext.3540 O(970)304-6498 fax a • ,ii,, tG unty Planning Department 6REELEY OFFICE APR 1 9 2005 eEcEivE. Weld County Referral COLORADO a5 5 March 28, 2005 The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5. For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. U We have reviewed the request and find that it does/does not comply with our Comprehensive Plan a We have reviewed the request and find no conflicts with our interests. U See attached letter. Comments: Signature AC/P A/21/4-4-1---- Agency )47 ,. ,_j Ain.,_cn Lor. OO Date Weld County Planning Dept. ❖918 10th Street, Greeley, CO. 80631 {•(970)353-6100 ext.3540 +(970)304-6498 fax APR.22.2005 1:28PM N0.218 P.li1 PEAIVNING DIVISp ,�, MAR 3 0 2605 RECEIVED Weld County Referral WilDe March 28, 2005 The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By "*AMIONNW Planner Project Site Plan Review for an electronics laboratory and offices Legal 1 ate 2acIV• ,i -iqintl_.f,tt N2 8-2-68 of the 6th P.M., Weld County, Colorado, , Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5, For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. I❑ We have reviewed the request and fit It does/does not comply with our Comprehensive Plan 12l We have reviewed the request and,fina'- rtrn,�ao �HM�rests, ❑ See attached letter. Comments: Signature �9�/4- � ` �I2ZIp� Agency C lcn,eaF Erna Mc7w5e Date ff SWeld County Planning Dept. +918 10'n Street, Greeley, CO. 80631 +(970)353.6100 ext.3540 +(970)304.6498 fax C, p ECflVC WP1d County Referral COLORADO March 28, 2005 MAR 3 0 2005 J The Weld County Department of IVEDI Af9INTEM Ifl5W@RIGEEPIiE following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5. For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. See attached letter. Comments: SignatureOititil / /9- O 5- Agency t .s Cr c_ �^, / Date ❖Weld County Planning Dept. +918 10'h Street, Greeley, CO. 80631 +(970)353-6100 ext.3540 G(970)304-6498 fax Weld County Planning Department GREELEY OFFICE P5411-.; MEMORANDUM APR 22 2005 I RECEIVED CTO: Chris Gathman, Planner II DATE: April 20, 2005 O FROM: Donald Carroll, Engineering Administrator COLORADO SUBJECT: SPR-385, Galt Properties The Weld County Public Works has reviewed this proposal. This project falls primarily under the purview of the Site Plan Review Standards, Weld County Code, Section 23-2-160. Our comments and requirements are as follows: COMMENTS: Lot 3, Block 2, Vista Commercial, Filing 1: The C3 Zoning district within the MUD consisting of 1.37 acres access shall be granted from the internal road system (Vista View Drive). Internal Road System: Vista View Drive is located within Vista Commercial Center. This roadway is paved and maintained by Weld County. The main access point is located at WCR 3.5, and there is a secondary access on to WCR 5. Both access points access State Highway 119. REQUIREMENTS: Access: access to the facility shall be through the internal road system (Vista View Drive). The applicant has indicated that there will be two paved access points to accommodate circulation, parking, and truck loading. Off-Street Parking: The facility is located within the MUD,which requires paving, concrete,or the equivalent,curb, gutter, and sidewalk with adequate on-site parking. The applicant has provided all of these items. There will be no staging or parking of vehicles on Vista View Drive. Utilize on-site parking only. Storm Water Drainage: The applicant's engineer, Jade P. Miller, P.E. with DMW Civil Engineering, has provided a drainage calculation for Lot 3, Block 2 of Vista Commercial. pc: SPR-385 M:\PLANNING-DEVELOPMENT REVIEW\5PR-Site Plan Review\SPR-385, Galt Properties.doc WELD COUNTY ROAD ACCESS INFORMATION SHEET Weld County Department of Public Works 111 H Street,P.O. Box 758, Greeley, Colorado 80632 Phone: (970)356-4000, Ext. 3750 Fax: (970) 304-6497 Road File#: Date: RE #: Other Case#7 1. Applicant Name Galt Properties. U C Phone (303) 931-7815 Address PO Box 2071 City Longmont State CO Zip 80502 2. Address or Location of Access 1736 Vista View Drive Longmont. Co Section 8 Township 2N Range 68 W Subdivision VCC Block 2 Lot 3 Weld County Road#:Vista View Dr Side of Road South Distance from nearest intersection 500 ft. 3. Is there an existng access to the property? Yes No X #of Accesses 4. Proposed Use: ❑ Permanent ❑ Residential/Agricultural ❑ Industrial ❑ Temporary D Subdivision 1 Commercial ❑ Other rrrtrarrrrarea*as*r*Mr aew+e*******e*r*»x+etw*rwe*r****Mwrxww`rt*sax+t**wfwxwr.***rwti+rtwwtrrrerea+w O**** 5. Site Sketch Legend for Access Desedption: AG = Agricultural Vista View Drive 1.--- RES = Residential O&G = Oil& Gas D.R. = Ditch Road A A O = House o = Shed Lot 3 > 0-, Blk 2 c A = Proposed Access v It T • = Existing Access ,, C o Co 0 Nfi 5 Skyway Drive arraararrrrrrrraararar.»rawrrarrrrraarr 7 n OFFICE USE ONLY: Road ADT Date Accidents Date Road ADT Date Accidents Date Drainage Requirement Culvert Size Length Special Conditions U Installation Authorized ❑ Information Insufficient Reviewed By: Tithe: • Jn ' ^ (*My Plannin, depart*.I t n FY OFFICE MAY u 4 2005 rre ;i0os , ' WED MEMORANDUM TO: CHRIS GATHMAN,PLANNING SERVICES FROM: CHARLOTTE DAVIS, ENVIRONMENTAL HEALTH ISUBJIECT:SPR-385 5GALTPROPERTIES DATE: 05/02/2005 COLORADO CC: Environmental Health Services has reviewed this proposal for an electronics laboratory and offices. We have no objections to the proposal, however, we do recommend that the following conditions be part of any approval: We recommend that the following requirements be met prior to allowing the plat to be recorded: 1. The applicant shall submit a waste handling plan, for approval, to the Environmental Health Services Division of the Weld County Department of Public Health & Environment. The plan shall include at a minimum, the following: 1) A list of wastes which are expected to be generated on site (this should include expected volumes and types of waste generated). 2) A list of the type and volume of chemicals expected to be stored on site. 3) The waste handler and facility where the waste will be disposed (including the facility name, address, and phone number). We recommend that the following requirements be incorporated into the permit as conditions that must be met prior to operation: 1. A stormwater discharge permit may be required for a development/redevelopment/construction site where a contiguous or non-contiguous land disturbance is greater than or equal to one acre in area. The applicant shall inquire with the Water Quality Control Division (WQCD) of the Colorado Department of Public Health and Environment at www.cdphe.state.co.us/wq/PermitsUnit if they are required to obtain a stormwater discharge permit. Alternately, the applicant can provide evidence from WQCD that they are not subject to these requirements. We recommend that the following requirements be incorporated into the permit as development standards: 1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. 2. No permanent disposal of wastes shall be permitted at this site. This is not meant to include those wastes specifically excluded from the definition of a solid waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended. 3. Waste materials shall be handled, stored, and disposed in a manner that controls fugitive dust, fugitive particulate emissions, blowing debris, and other potential nuisance conditions. 4. The applicant shall operate in accordance with the approved "waste handling plan". 5. The operation shall comply with all applicable rules and regulation of the Federal Communications Commission (FCC) and the Code of Federal Regulation (CFR). 6. Fugitive dust and fugitive particulate emissions shall be controlled on this site. 7. This facility shall adhere to the maximum permissible noise levels allowed in the Commercial Zone as delineated in 25-12-103 C.R.S., as amended. 8. Adequate handwashing and toilet facilities shall be provided for employees and patrons of the facility. 9. The facility shall utilize the existing municipal sewage treatment system. (St. Vrain Sanitation District) 10. The facility shall utilize the existing public water supply. (Left Hand Water District) 11. All potentially hazardous chemicals must be stored and handled in a safe manner in accordance with product labeling and in a manner that minimizes the release of hazardous air pollutants (HAP's) and volatile organic compounds (VOC's). 12. If applicable, the applicant shall obtain a stormwater discharge permit from the Colorado Department of Public Health & Environment, Water Quality Control Division. 13. The operation shall comply with all applicable rules and regulations of the State and Federal agencies and the Weld County Code. 2 iit, z.--% -YD1 lungeWeld County Referral COLORADO March 28, 2005 The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5. For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. See attached letter. Comments: Signature V -a7, OS Agency Date ❖Weld County Planning Dept. +918 10'"Street, Greeley, CO.80631 4(970)353-6100 ext.3540 4(970)304-6498 fax rie}cr(0 Qwee DEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION NORTH OFFICE 918 Street GREELEY, COLORADO 80631 I PHONE (970)353-6100, EXT.3540 WI D (970) 304-6498 cFAX SOUTHWEST OFFICE 4209 CR 24.5 COLORADO PHONE LONGMONT CO 80504 (720)652-4210 ext. 8730 FAX (720)652-4211 April 26, 2005 Galt Properties. SPR-385 A Site Plan Review for an electronics laboratory and offices. 1. A building permit shall be obtained prior to the construction of any new building. 2. A plan review is required for each building for which a building permit is required. Plans shall include a floor plan. Plans shall bear the wet stamp of a Colorado registered architect or engineer. Two complete sets of plans are required when applying for each permit. A Code Analysis Data sheet provided by the Weld County Building Department shall be submitted with each Building permit application. 3. Buildings shall conform to the requirements of the various codes adopted at the time of permit application. Currently the following has been adopted by Weld County: 2003 International Building Code; 2003 International Mechanical Code; 2003 International Plumbing Code; 2003 International Fuel Gas Code; and the 2002 National Electrical Code and Chapter 29 of the Weld County Code. 4. Each building will require an engineered foundation based on a site-specific geotechnical report or an open hole inspection performed by a Colorado registered engineer. Engineered foundations shall be designed by a Colorado registered engineer. 3 The building will probably be classified as a B (Electronic Laboratory and Office). Fire resistance of walls and openings, construction requirements, maximum building height, automatic sprinkler requirements and allowable areas will be reviewed at the plan review. Setback and offset distances shall be determined by the Zoning Ordinance. Mountain View Fire Protection District requirements for automatic sprinklers may be different than the requirements of the 2003 International Building Code. 6. Building height shall be measured in accordance with the 2003 International Building Code for the purpose of determining the maximum building size and height for various uses and types of construction and to determine compliance with the Bulk Requirements from Chapter 27 of the Weld County Code. Building height shall be measured in accordance with Chapter 23 of the Weld County Code in order to determine compliance with offset and setback requirements. Offset and setback requirements are measured to the farthest projection from the building. Please contact me for any further information regarding this project. Sin ly, er 191 Building Official Service,Teamwork,Integrity,Quality r;st's Weld County Referral COLORADO March 28, 2005 • The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5. ' For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. ❑ See attached letter. Comments: • Signature 1,tl, 4' it OS Agency . ti µ (c . t N Date +Weld County Planning Dept. <•918 10'h Street, Greeley, CO. 80631 +(970)353-6100 ext.3540 4•(970)304-6498 fax MEMORANDUM TO: Chris Gathman, Planner II COLORADO DATE: April 11, 2005 FROM: Kim Ogle, Planning Manager SUBJECT: Site Plan Review 385 Galt Properties, LLC Vincent Greb & Shauna Custer, Applicant The Department of Planning Services reviewed the above referenced Site Plan Review documentation and drawings and offers the following comments: The Site Plan Review Plat shall be prepared in accordance with Section 23-2-160.V of the Weld County Code. This application shall be in compliance with Section 23-3-250 A. and B, Section 23-3-350 and Chapter 26 and is address in the following comments. The proposal is located in the Western Dairymen Cooperative PUD. Zoning within this PUD is C-3 and I-1. Section 23-3-250.A.1 Stormwater Management. All users of land shall provide and maintain stormwater retention facilities designed to retain the stormwater runoff in excess of historic flow from the undeveloped site. The stormwater retention facility on a developed site shall be designed for a one-hundred-year storm. The stormwater retention facility shall be designed and operated to release the retained water at a quantity and rate not to exceed the quantity and rate of a five- year storm falling on the undeveloped site. The application materials state that the storm water management plan prepared by Pickett Engineering, Greeley was reviewed by Jape P. Miller of DMW Civil Engineers, Inc whi in his professional opinion, the stormwater issue has been addressed. There was supporting documentation providing written calculaions and analysis. Section 23-3-250.A.2 Parking. Sufficient screened, off-street, paved parking areas shall be provided to meet the requirements of employees, company vehicles, visitors and customers of the Uses Allowed by Right and Accessory Uses. Appendix 23-A describes the design requirements for parking spaces and Appendix 23-B delineates the number of parking spaces required by use for this property. The proposed facility has Office and Laboratory uses. The parking requirement for Office uses are one space for every two employees plus one space per 500 SF. The area delineated on the drawings submitted is 2694 SF, with written documentation stating there are an unknown number of office personnel on premises. The laboratory area requires one space for every 1000 SF of area. The area delineated on the drawings submitted is 7937 SF, with written documentation stating there are six (6) persons on premises. Per Code, the total parking required for this facility may not be calculated. The applicant has provided 24 parking spaces which includes one van accessible space: The Department of Planning Services has determined that this number will adequately address the parking requirement. Section 23-3-250.A.3 Street Access. Lots shall have safe access to an approved public or private street. The design designation of any street or highway as to type shall be in conformance with that shown on the county thoroughfare plan and/or the master plan of the affected municipality. The existing access is off of Vista View Drive within the Vista commercial Center PUD. The Department of Public Works shall address any additional ingress and egress issues. Section 23-3-250.A.4 Required Yards - Setback No use or accessory use may be located closer than twenty-five (25) feet to the existing or proposed (whichever represents the greater right-of-way width) highway or street right-of-way. Off-street parking areas may be permitted in the required setback area when the area is screened from direct view of persons on the public rights-of-way. Fences over six (6) feet in height are not required to comply with the minimum setback and may be located on the property line. Fences located on corner lots abutting public right-of-way shall not obstruct the view of vehicular traffic at an intersection. There was a scaled elevational drawing of the structure included in the application materials, delineating no outside storage. Section 23-3-250.A.4 Required Yards - Offset No use or accessory use may be located closer than ten (10) feet to its lot line. Fences over six (6) feet in height are not required to comply with the minimum offset and may be located on the property line. The plans submitted with the application materials have delineated the offset. Section 23-3-250.A.5.A Required Landscaped Areas No more than eighty-five percent (85%) of the total area of a lot shall be covered. Land shall not be deemed covered if it is used for growing grass, shrubs, trees, plants or flowers or if covered by decorative gravel or wood chips, or if it is otherwise suitably Landscaped. There was a schematic Landscape and Screening Plan submitted with the application materials. Section 23-3-250.A.5.B That portion of a lot which abuts a public or private street right-of-way shall be landscaped for a distance of ten (10) feet, measured at a right angle from the lot line towards the interior of the lot. Sidewalks and driveways may pass through the required landscaped areas. The Landscape and Screening Plan submitted with the application materials address this issue. Section 23-3-250.A.6 Areas used for trash collection shall be screened from public rights-of-way and all adjacent properties. These areas shall be designed and used in a manner that will prevent wind- or animal-scattered trash. The application materials do identify the location of the screened trash enclosure. Section 23-3-250.A.7 Water Supply. Uses shall have an adequate source of potable water. The application materials state that water is provided by Left Hand Water District. The applicant shall meet the requirements of the District and provide the Department of Planning Services with written evidence of service. • Section 23-3-250.A.8 Sewage Disposal. Uses shall have adequate sewage disposal facilities. The application materials state that sanitary sewer will be provided by the St. Vrain Sanitation District. The applicant shall meet the requirements of the District and provide the Department of Planning Services with written evidence of service. Section 23-3-250.A.9 Outside Storage. Uses involving outdoor storage of vehicles, equipment or materials when permitted shall be screened from public rights-of-way and all adjacent properties. The application materials and supporting drawings do not indicate there is outside storage. Section 23-3-350.B. Operation Standards. Uses shall demonstrate conformance with the following operation standards to the extent that they are affected by location, layout and design prior to construction and operation. Once operational, the operation of the Uses permitted shall conform to these standards. Section 23-3-350.6.1 Noise. Uses and structures shall be located, designed and operated in accordance with the noise standards as established in Section 25-12-101 C.R.S. The applicant shall meet the established standards set by the Weld County Department of Public Health and Environment. Section 23-3-250.B-2 Air Quality. Uses shall be located, designed and operated in accordance with the air quality standards established by the Colorado Air Pollution Control Commission. The applicant shall meet the established standards set by the Weld County Department of Public Health and Environment. Section 23-2-250.B.3 Water Quality. Uses shall be located, designed and operated in accordance with the water quality control standards established by the Colorado Water Quality Control Commission. Section 23-2-250.6.4 Radiation and Radioactive Materials. The handling, use, storage and processing of radioactive materials shall be in accordance with the applicable regulations of the State and the United States Government The application materials do not indicate this is applicable, should this not be the case, the applicant shall provide additional information to the Weld County Department of Public Health and Environment. Section 23-2-250.B.5 Heat. Uses shall not emit heat in such an amount sufficient to raise the temperature of the air or of materials at or beyond the Lot line more than five (5) degrees Fahrenheit. The application materials do not indicate this is applicable, should this not be the case, the applicant shall provide additional information to the Weld County Department of Public Health and Environment and the Department of Building Inspection. Further, the applicant shall obtain a written approval from the Mountain View Fire Protection District stating that the facility is in compliance with the Fire Code. Section 23-2-250.B.6 Light. Any lighting, including light from high temperature processes such as welding or combustion, shall be designed, located and operated in such as manner as to meet the following standards: sources of light shall be shielded so that beams or rays of light will not shine directly onto adjacent properties; neither the direct nor reflected light from any light source may create a traffic hazard to operators of motor vehicles on public or private streets; and no colored lights may be used which may be confused with or construed as traffic control devices. The application materials did not include a Lighting Plan. Should exterior lighting be a part of this facility, all light standards shall be delineated on the Site Plan Review Plat. Section 23-2-250.6.7 Property Maintenance. Property shall be maintained in such a manner that grasses and weeds are not permitted to grow taller than twelve (12) inches. In no event shall the property owners allow the growth of noxious weeds. The application materials do not address property maintenance. Future correspondence shall identify how the property will be in compliance with this Section of the County Code. The applicant shall submit a written agreement with the oil and gas interests stating that the concerns of this entity have been addressed. This shall include a surface and subsurface agreement. This agreement shall be reviewed by the County Attorney's office prior to the recording of the Site Plan Review plat, and the acceptance of the collateral associated with this project. Section 23-4-50. Off Street Loading. The applicant shall delineate on the Site Plan Review plat the location of the loading zone that is in compliance with Section of the Code. There shall be no parking or staging of trucks within the public right-of way. Further, the applicant shall meet all requirements of the Department of Public Works concerning access and circulation of vehicles for this proposed facility. Section 23-4-90 Signs. The application materials do not address the issue of on-site signs, however, the Landscape, Signage and Lighting Plan identifies sign locations on site Section 23-4-90 addresses signs located in the Commercial and Industrial Zone District. The applicant shall provide written evidence that all proposed signs are in compliance with this section of the Code. Section 26 addresses the requirements of the Mixed Use Development Area, (MUD). The following criteria, if more restrictive shall apply to this site. Section 26-2-30.E Limiting Site Factors. The entire parcel under review per this application is not located within the floodplain. Section 26-2-40 Common Open Space. Appendix 26-E discusses common open space requirements. Per the Code, thirty (30) percent of Common Open Space is required for this site given that it is located in an area with limited site Factors. For reference only, twenty (20) percent is the typical requirement for open space in the MUD. Section 26-2-50 Maximum Lot Coverage. All land use applications in the MUD area shall adhere to the regulations governing the maximum percentage of lot coverage. The maximum lot coverage is defined as the maximum percent of the total area of a lot in a zone district that shall be covered by any structure. Land shall not be deemed covered if it is used for growing grass, shrubs, trees, plants or flowers it is covered by decorative gravels or wood chips, or if it is otherwise suitably landscaped. The percentage of coverage on a lot shall not include the area of the lot or development designated as common open space as outlined in Appendix 26-E (30 Percent as previously stated). The percentages outlined in Table 26.1 shall be deemed the maximum lot coverage for each zone district within the MUD area. In this instance, the maximum lot coverage is eight-five (85) percent of the total allowable area. By calculation, approximately 50725 SF is buildable. Section 26-2-70.A Landscaping Regulations, Intent. Landscaping is extremely important for ensuring the quality of development in the MUD area. Trees, shrubs and other plantings add greatly to the aesthetic appeal while controlling erosion, reducing glare, lowering temperatures, buffering sounds and blocking or diverting wind. As no single landscaping plan can be prescribed for all • developments due to differing land features, topology and soils, the County allows flexibility and encourages creativity in landscape designs. Landscaping must be sensitive to the characteristics and maintenance requirements of the planting selected. Species must be chosen that are hardy for the climate and soil conditions in the MUD area, that can tolerate traffic, that are resistant to disease and insects, and whose maintenance needs can be met. Section 26-2-70.B Design Criteria. Landscapes shall utilize the following principles for maximum use of water: (a) well-planned and approved planting schemes; (b) appropriate selection of drought-tolerant turf species to minimize water needs and the use of water-hungry species of turf; (c) mulch to reduce evaporation; (d) zone plant groupings according to their microclimatic needs and water requirements; (e) improvement of the soil with organic matter if needed; (f) efficient irrigation design; and (g) proper maintenance and irrigation scheduling. The applicant has provided evidence, both graphically and written stipulating compliance with this Section of the Code. Section 26-2-70.C.1 Landscaping Requirements for Parking Lots. At least ten percent (10%) of the area of a parking lot must be landscaped if the lot contains ten (10) or more spaces. The requirement may be counted toward the maximum lot coverage requirement of each zone district. At least seventy-five percent (75%) of the required landscape area shall include living plant material. Section 26-2-70.C.2 Berming and shrub or tree planting shall be used to screen parking lots from view of the roadway. Berms can vary in height depending on location and proximity of existing trees. Berms shall have smooth transitions from the top of the curb to the setback line so as to not create snow traps, with allowances made for placement of the sidewalk. Grading of berms shall not be lumpy or abrupt. Section 26-2-70.C.3 Landscaping techniques shall be used to alleviate the harsh visual appearance that accompanies parking lots. At least seventy-five percent (75%) of the length of the frontage of the parking lot must be effectively screened. Section 26-2-70.C.4 A minimum of five percent (5%) of the parking area shall be landscaped exclusive of setback areas. Trees planted in parking areas should be either in bays or planting islands of at least five (5)feet by five (5) feet. Trees should be distributed throughout the parking area, however, they shall be placed so that they do not obstruct visibility for cars and pedestrians. Section 26-2-70.C.5 Loading, service or storage areas must be screened with an opaque screen that is an integral part of the building architecture. Chain link fencing with slats or pallets are not an acceptable screening material. Plant material shall be used to soften the appearance of the screen. Section 26-2-70.D.2 Landscaping Requirements Along Roadway Corridors - Design Intent. The applicant shall provide evidence, both graphically and written stipulating compliance with this Section of the Code. Of particular note are the following Sections: Section 26-2-70.D.2.a. Plantings along road rights-of-way shall be integrated with the rest of the site. Section 26-2-70.D.2.b That portion of a lot in any zone district which abuts a public or private road right-of-way shall be landscaped with a minimum two-and-one-half-inch caliper shade tree or six-foot minimum height coniferous tree at a distance of ten (10) feet, measured at a right angle from the lot line towards the interior of the lot, for every forty (40) linear feet of street frontage. Trees may be grouped with a maximum distance of one hundred (100) feet between trees or groupings, with exceptions made at entrance drives. Section 26-2-70.D.2.c A minimum landscape setback along 1-25, State Highway 119 and their subsequent frontage roads shall be fifty (50) feet measured from the existing or planned future right-of-way. This section is not applicable. Section 26-2-70.D.2.d Along 1-25, State Highway 119, State Highway 66 and WCR 1, tree planting distances shall be clustered or grouped from the roadway to avoid a straight line of trees. The effectiveness of the screening shall be increased by planting trees and shrubs in layered beds (two [2] or more rows of plant material rather than a single row). A mix of coniferous and deciduous trees and shrubs shall be planted in clusters or groupings. This section is not applicable. Section 26-2-70.D.2.e Applicants adjacent to 1-25 and/or State Highway 119 shall construct a berm along 1-25 and/or State Highway 119 with maximum 5:1 side slopes to a height sufficient to screen ground plane development (parking lots, storage areas or other similar site elements) as far as one hundred eighty (180) feet from the right-of-way line (fifty [50] feet of landscape setback plus one hundred thirty [130] feet of site development). The maximum height berm required shall be six (6) feet above the existing elevation in the location of the berm. If needed, additional height beyond that which can be achieved with asix-foot-high berm shall be achieved through dense landscape plantings. Plantings on top of berms shall be designed so as to not create snow traps. A berm may not be required if the subject property is elevated above the roadway and it can be demonstrated that views into the site will not be possible for a distance of one hundred eighty (180) feet. Required landscaping and screening within the landscape setback and other portions of the property shall be governed by the landscape standards contained within this Chapter (Chapter 26) and any other more restrictive requirements contained in Chapter 23 of the Code. This section is not applicable. Section 26-2-70.D.2.g There shall be a minimum twenty-foot-wide landscape setback measured from the existing or planned future right-of-way to any parking lot, fencing, storage area or structure. Required landscaping and screening within the landscape setback and other portions of the property shall be governed by the landscape standards contained within this Chapter (Chapter 26) and any other more restrictive requirements contained in Chapter 23 of the Code. Section 26-2-70.D.2.h Appendices 26-M through 26-P contained within this Chapter (Chapter 26) illustrate the proposed character, berming and landscape setbacks for the State Highway 119 corridors. This section is not applicable. (Weld County Codification Ordinance 2000-1) Section 26-2-80.C and Section 26-2-80.D addresses access and circulation. The applicant shall contact the Department of Public Works to address all issues pertaining to this topic. The Department of Planning Services shall require an agreement with the Oil and Gas interests for the secondary access to the south of the parcel. Further, the Mountain View Fire Protection District shall be consulted on this access and the applicant shall provide written evidence that the concerns of the Mountain View Fire Protection District have been addressed to their satisfaction and requirements. Section 26-2-90 Sign District Requirements. The applicant shall provide evidence, both graphically and written stipulating compliance with this Section of the Code. Specific attention shall be given to Section 26-2-90.D.2 of the Code. The applicant shall enter into an Improvements Agreement according to policy regarding collateral for improvements and post adequate collateral for all transportation (access drive, parking areas, etcetera) and non-transportation (plant materials, fencing, screening, etcetera). The agreement and form of collateral shall be reviewed by County Staff and accepted by the Board of County Commissioners prior to recording the Site Plan Review plat. a weld County Planning Department GREELEY OFFICE APR 1 5 2005 APR - 1 2005 RECEIVED Weld County Referral COLORADO March 28, 2005 The Weld County Department of Planning Services has received the following item for review: Applicant Galt Properties Case Number SPR-385 I Please Reply By April 26, 2005 Planner Chris Gathman Project Site Plan Review for an electronics laboratory and offices Legal Lot 3, Block 2 Corrected Vista Commercial Filing 1; Pt N2 8-2-68 of the 6th P.M., I Weld County, Colorado. Location South of and adjacent to Vista View Drive; Approximately 1/4 mile west of CR 3.5. For a more precise location, see legal. Parcel Number 1061 05 000037 The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. ❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan ❑ We have reviewed the request and find no conflicts with our interests. SI See attached letter. Comments: Signature ( L . ( �'Cy1 L\ � \ 3 Agency tV\ \F„ }4 e ��. (h.:Lc Date 4-Weld County Planning Dept. +918 10'h Street, Greeley, CO.80631 4(970)353-6100 ext.3540 4(970)304-6498 fax *oUNT4l4, MOUNTAIN VIEW FIRE PROTECTION DISTRICT a Administrative Office: 9119 County Line Road• Longmont, CO 80501 e (303) 772-0710• FAX (303) 651-7702 �� F VIEW April 13, 2005 Mr. Chris Gathman Weld County Planning Department 918 10th Street Greeley, CO 80631 Dear Mr. Gathman: I have reviewed the submitted material and site plans for the proposed Galt Properties building to be located at 1736 Vista View Drive in Weld County(Case Number: SPR-385). The Fire District has the following comments with regard to the project: • Buildings shall be designed and constructed in accordance with the provisions of the Uniform Fire Code, as ratified by the Weld County Commissioners. • The total building appears to be about 10,630 square feet. If the building is constructed of type V-N construction the required water supply for fire protection is 2,750 gallons per minute, measured at a residual pressure of 20 pounds per square inch. Changing the building construction type to type V-lhr, type H-N or type III-N will reduce the required fire flow. The addition of fire sprinklers will also reduce the required fire flow. This can be addressed at the type building construction plans are received for review. • Fire apparatus access to the building appears to be adequate as indicated on the plans. Fire apparatus access roads must be designed and maintained to support the imposed loads of fire apparatus (75,000 pounds) and be free from obstructions which includes locked gates unless otherwise approved. The minimum turning radii for all turns shall be thirty-five (35) feet inside turning radius and forty-eight (48) feet outside turning radius. Access roads will need to be constructed and approved before building permits are issued. • Dumpsters shall not be located within 5 feet of a building opening or within 5 feet of combustible walls or combustible roof eaves. The dumpster appears to be too close to the door on the south side of the building and may need to be relocated to the east. • Building construction plans and a final site plan showing the gross square footage of the building and building construction type must be submitted by the applicant to the Fire for review and approval before building permits may be issued. • A final inspection of the occupancy will be required by a member of the Fire District before a Certificate of Occupancy is issued from Weld County. Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 9119 Cnty Line Rd. 10971 WCR 13 P.O.Box 575 P.O.Box 11 10911 Dobbin Run 50 Bonanza Dr. P.O.Box 40 Longmont,CO Longmont.CO 299 Palmer Ave. 8500 Niwot Road Lafayette.CO Erie.CO 100 So.Forest St. 80501 80504 Mead.CO 80542 Niwot.CO 80544 80026 80516 Dacono,CO 80514 Mr. Chris Gathman April 13, 2005 Page Two The Fire District reserves the right to make further comments as the project proceeds. Nothing in this review is intended to authorize or approve of any aspect of this project that does not comply with all applicable codes and standards. We appreciate being involved in the planning process. Should you have any questions, please contact me at(303) 772-0710. Sincerely, LuAnn Penfold Fire Marshal LMP/lp cc: project file 104.13.05 Recorded at o'clock Reception No. Recorder SPECIAL WARRANTY DEED THIS DEED,Made this 16th day of March,2005,between HORIZON INVESTMENTS L.LC of the County of BOULDER and State of Colorado, grantor(s), and GALT PROPERTIES LLC whose legal address is P.O.BOX 2071, LONGMONT,CO 80502 of the County of BOULDER and State of Colorado,grantee(s): WITNESSETH, That the grantor(s), for and in consideration of the sum of TWO HUNDRED FIFTY-FIVE THOUSAND AND 00/100 DOLLARS, the receipt and sufficiency of which is hereby acknowledged, has granted, bargained,sold and conveyed, and by these presents does grant,bargain,sell,convey and confirm,unto the grantee(s), its'heirs and assigns forever, all the real property, together with improvements, if any, situate, lying and being in the County of WELD,State of Colorado,described as follows: LOT 3, BLOCK 2, VISTA COMMERCIAL CENTER FILING 1. ACCORDING TO THE CORRECTED PLAT RECORDED AUGUST 28, 1997 IN ROOK 1623 AS RECEPTION NO.2566006, COUNTY OF WELD,STATE OF COLORADO. RESERVING UNTO GRANTOR ALL MINERAL RIGHTS INCLUDING ORES, METALS AND MINERALS OF ANY KIND AND CHARACTER INCLUDING RIGHTS TO SAND AND GRAVEL, COAL, AND TO OIL, GAS AND OTHER LIKE SUBSTANCES IN AND UNDER SUCH LAND. GRANTOR, SUCCESSORS AND ASSIGNS AGREES TO NEITHER AUTHORIZE NOR ENGAGE IN ANY ACTIVITIES RELATED TO DRILLING, EXPLORATION, OR EXTRACTION OF ANY MINERALS OF ANY KIND ON THE PROPERTY HEREIN CONVEYED. also known as street and number as:1736 VISTA VIEW DRIVE,LONGMONT,CO 80504 TOGETHER with all and singular the hereditaments and appurtenances thereunto belonging, or in anywise appertaining, and the reversion and reversions,remainder and remainders,rents, issues,and profits thereof, and all the estate,right,title,interest,claim and demand whatsoever of the grantor(s),either in law or equity,of,in and to the above bargained premises,with the hereditaments and appurtenances. TO HAVE AND TO HOLD the said premises above bargained and described with the appurtenances, unto the grantee(s), his/her heirs, and assigns forever. The grantor(s), for itself/its' heirs, and personal representatives or successors,does covenant and agree that it shall and will WARRANT AND FOREVER DEFEND the above-bargained premises in the quiet and peaceable possession of the grantee(s), its'heirs and assigns,against all and every person or persons claiming the whole or any part thereof,by,through or under the grantor(s). IN WITNESS WHEREOF,The grantor(s)has executed this deed on the date set forth above. HORIZON INVESTMENTS,LL.C � t • by: MANAGER BY: MANAGER STATE OF COLORADO, ss. County of BOULDER The foregoinginstrument was acknowledged before this 16th day of MARCH, 2005 by 'CI\OJw %Yin. OC0LAND AS MANAGERS FOR HORIZON INVE 'rMENTS LLC. (� Witness my hand and official�seal. My commission expires: -e"'Sl&K Zu ZUJ`I' • Notary Public flip Denver.insert"City and". No.is.Rev.3-85. SPECIAL WARRANTY DEED —63 Vision Form 50DWC0 Rev.03110/98 .... � ., �..`... ��.�.� �ri ,� „ice ♦,�,L41 f-4,1C. Ul ' "•' -.,•oor nonenzte uoia 7206520296 p, 1 j . e.3/11/2005 15:30 1• 6S1-1320 DYER REALTY INC PAGE 03 ' UTILITY AND STORM DRAINAGE EASEMENT KNOW ALL MEN BY THESE PRESENTS that Raritan Investments LLC,a Colorado Limited Liability Company,heteiadter referred to as"Grantor,'hereby grams and conveys to the public a utility and swim drainage casement. Below Is a desetiption of the easement. Located In the Nona Half of Seaton il, Township 1 North. Range alt West of the tis Principal Meridian,Weld County,Colorado;the Winton ten(bit(10')of Lot 3,Block 2,of the Corrected Nat of Vista Commercial Center The utility and steam drainage easement hereby granted shell entitle the public to install, lay, construct. relocate,change the sin of,replace, repair, inspect, maintain, remove,and operate an underground utility and storm drainage lines attd all appurtenances thereto, The utility and dorm drainage easement also than permit uses clearly Incidental to those specified and shall Include the right of ingress and egrets over and across the Grantor's propeny to the extent reasonably neeeseasy to itemise and accomplish the utility purposer, The Grantor shall have the right to make nee of the surface overlying the easement panted by this instrument so long as such use does not Interfere with the exercise by the Grantee of the rights granted and conveyed by this Inauvment. No pernanent structures ate to be built within this easement. Thisgrant shall be binding upon the hors,axdeuton,edmintatatora,successors,and assigns of the partial hereto. IN WITNESS WHEREOF,the Grantor has hereunto set their hands end seals on this / IA day of "111 on c.ic ,2005. � JJ 29Ar .p.1 i JA c ay: (Oranko �'w{e 4 "tY '.., a • d aTIS t '•-•,/,`-."'-`,. TI + , 'I Y CIS �f Y/• o3"C ic: oar bi Y t ` rt 1 C 1 _ ,: t a . _ _ __ _ ___. ._._ � iv rHUG O1 • Commitment No. 20312 WK SCHEDULE B-2 Exceptions The policy or policies to be issued will contain exceptions to the following unless the same are disposed of to the satisfaction of the Company: 1. Rights or claims of parties in possession not shown by the public records. 2. Easements or claims of easements,not shown by the public records. 3. Discrepancies, conflicts in boundary lines, shortages in area, encroachments,and any facts which a collect survey and inspection of the premises would disclose and which are not shown by the public records. 4. Any lien, or right to a lien for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the public records. 5. Defects, liens, encumbrances, adverse claims, or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6. Unpatented mining claims: reservations or exceptions in Patents or in Acts authorizing the issuance thereof,water rights,claims or title to water; NOTE: Item no. 6 of the above will not appear on the Lender's Policy(if any)to be issued hereunder. 7. Taxes and assessments which are a lien or are now due and payable;any tax,special assessment,charge or lien imposed for or by any special taxing district or for water or sewer service;any unredeemed tax sales. S. RIGHT OF THE PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE HIS ORE THEREFROM,SHOULD THE SAME BE FOUND TO PENETRATE OR INTERSECT THE PREMISES HEREBY GRANTED,AS RESERVED IN UNITED STATES PATENT RECORDED MARCH 21, 1885 IN BOOK 34 AT PAGE 118. 9. OIL AND GAS LEASE FROM C.P. RICHARDSON, LEO F. KNAGO AND BETTY JO SECOR TO BUDDY BAKER, RECORDED MAY 29, 1980 IN BOOK 904 AS RECEPTION NO. 1826006;AMENDMENT RECORDED SEPTEMBER 17, 1984 IN BOOK 1043 AS RECEPTION NO. 1981953;CORRECTION OF DESCRIPTION IN LEASE RECORDED SEPTEMBER I7, 1984 IN BOOK 1043 AS RECEPTION NO. 1981954 AND RECORDED SEPTEMBER 14, 1984 IN BOOK 1043 AS RECEPTION NO. 1981769;AFFIDAVIT OF PRODUCTION RECORDED OCTOBER 3, 1985 IN BOOK 1086 AS RECEPTION NO.2027311,AND ANY INTERESTS THEREIN,ASSIGNMENTS,OR CONVEYANCES THEREOF. 10. TERMS,CONDITIONS,PROVISIONS,OBLIGATIONS AND AGREEMENTS OF THAT CERTAIN SUBDIVISION SERVICE AGREEMENT BETWEEN THE ST. VRAIN SANITATION DISTRICT AND HORIZON INVESTMENTS, L.L.C. RECORDED APRIL 14, 1997 IN BOOK 1600 AS RECEPTION NO.2542719. I I. TERMS,CONDITIONS, PROVISIONS,OBLIGATIONS AND AGREEMENTS OF THAT CERTAIN SUBDIVISION MULTIPLE TAP SERVICE AGREEMENT BETWEEN LEFT HAND WATER DISTRICT AND HORIZON INVESTMENTS, LLC RECORDED APRIL 21, 1997 IN BOOK 1601 AS RECEPTION NO,2543820. 12. TERMS,CONDITIONS, PROVISIONS,OBLIGATIONS AND AGREEMENTS OF THAT CERTAIN IMPROVEMENTS AGREEMENT BETWEEN THE COUNTY OF WELD AND HORIZON INVESTMENTS LLC,RECORDED MAY 27, 1997 fN BOOK 1608 AS RECEPTION NO. 2549895. 13. TERMS,CONDITIONS, PROVISIONS,OBLIGATIONS AND AGREEMENTS OF THAT CERTAIN ROAD MAINTENANCE AND IMPROVEMENTS AGREEMENT BETWEEN THE COUNTY OF WELD AND HORIZON INVESTMENTS,LLC RECORDED MAY 27, 1997 IN BOOK 1608 AS RECEPTION NO.2549896. 14, NOTES AND EASEMENTS AS SHOWN AND SET FORTH ON THE RECORDED PLAT OF VISTA COMMERCIAL CENTER FILING I, ACCORDING TO THE CORRECTED PLAT RECORDED AUGUST 28, 1997 AS RECEPTION NO. 2566006. ...., �, ..vv.. .r.w .-,uv• ,v, LVrtl, r rMUG O2 SCHEDULE B-2 -Continued Commitment No. 20312WK 15. COVENANTS, CONDITIONS AND RESTRICTIONS WHICH DO NOT CONTAIN FORFEITURE OR REVERTER CLAUSE,OMITTING ANY RESTRICTIONS BASED ON RACE,COLOR,RELIGION OR NATIONAL ORIGIN, CONTAINED IN INSTRUMENT RECORDED AUGUST 7, 1997 IN BOOK 1620 AS RECEPTION NO.2562470 AS AMENDED AND RESTATED BY INSTRUMENT RECORDED APRIL 22, 1998 AS RECEPTION NO.2607807 AND FIRST AMENDMENT RECORDED JUNE 25,2003 AS RECEPTION NO. 3076912. 16. ANY ASSESSMENTS OR LIENS BASED UPON ASSESSMENTS IMPOSED BY ANY RECORDED DECLARATION OF COVENANTS, CONDITIONS OR RESTRICTIONS OR IMPOSED BY LAW FOR THE BENEFIT OF HOMEOWNERS ASSOCIATION OR A COMMON INTEREST OWNERSHIP ASSOCIATION. 17. WATER,WATER RIGHTS,CLAIMS OF TITLE OR INTEREST IN WATER, 18. ANY EXISTING LEASES OR TENANCIES. 19. EASEMENT OVER THE NORTHERLY IS FEET OF SUBJECT PROPERTY FOR DRAINAGE AND UTILITIES AS SHOWN ON THE RECORDED PLAT OF SUBDIVISION. 20. EASEMENT OVER THE EASTERLY 10 FEET OF SUBJECT PROPERTY FOR DRAINAGE AND UTILITIES AS SHOWN ON THE RECORDED PLAT OF SUBDIVISION. NOTE: COLORADO REVISED STATUES 10-11.123 REQUIRES THE FOLLOWING NOTICE THAT THERE IS RECORDED EVIDENCE THAT A MINERAL ESTATE HAS BEEN SEVERED,LEASED OR OTHERWISE CONVEYED FROM THE SURFACE ESTATE AND THAT THERE IS A SUBSTANTIAL LIKELIHOOD THAT A THIRD PART HOLDS SOME OR ALL INTEREST IN OIL, GAS,OTHER MINERALS, OR GEOTHERMAL ENERGY IN THE PROPERTY;AND THAT SUCH MINERAL ESTATE MAY INCLUDE THE RIGHT TO ENTER AND USE THE PROPERTY WITHOUT THE SURFACE OWNER'S PERMISSION. .,.,, ...,.., ....,. .,... vuuua,uui • =IMME�� -�1�1 mss =N 1C' Left Hand Water District March 9, 2005 Jade P. Miller, P. E. DMW Civil Engineers, Inc. 1435 W. 29" Street Loveland, CO 8D538 Re : Vista Commercial Block 2 Lot 3 TO WHOM IT MAY CONCERN: The property located at the above legal description is within the "Service Area" of Left Hand Water District and water service is available in this commercial subdivision. when review and approval of engineering requirements and payment of all fees is complete, commercial service will be provided. There is a specific time period for completion of the tap. Failure to comply to any of the conditions within the stated time period would cause the request for water service to be void. Sincerely, ., •eln Kim Lane Administrative Assistant Leh Hand Water District P.O. Box 210-Niwot, CO 80544-0210 ti Phone 303-530-4200-Fax 303-530-5252 ru www.lefthandwater.dst.co.us ♦�i St. Vrain IRANI TATI ON DISTRICT March 10, 2005 DMW Civil Engineers, Inc. 1435 W. 29`t' Street Loveland, Co 80538 Re: Sanitary Sewer Service Vista Commercial—Lot 3 Block 2 Weld County, Colorado Saint Vrain Sanitation District will provide sanitary sewer service to Lot 3 Block 2 of Filing 1 in Vista Commercial, Longmont,CO,subject to the following conditions: • Completion of necessary connection agreements • Installation of pretreatment appurtenances • Submission of all required drawings • Receipt of applicable fees • Service will be subject to the rules and regulations of the Saint Vrain Sanitation District Sincere v o s, Robert Fleck District Engineer St. Vrain Sanitation District • • • 11307 Business Park Circle Longmont, CO 80504 Phone (303) 776-9570 Fax (303)485-1988 Hello