HomeMy WebLinkAbout20050229.tiff Weld County Planning Department
GREELEY OFFICE
MEMORANDUM NOV B friRECEI' / Lr
WligC TO: Chris Gathman, Planner II DATE: November 16, 2004
FROM: Donald Carroll, Engineering Administrator yi
COLORADO SUBJECT: USR-1494, Anthony & Diane Goddard
The Weld County Public Works Department has reviewed this proposal. This project falls primarily under the
purview of the Use by Special Review Standards, Weld County Code, Chapter 23, Article II, Division 4, Section
23. Our comments and requirements are as follows:
COMMENTS:
WCR 2 is designated on the Weld County Road Classification Plan (FHU) as an arterial road, which requires a
140-foot right-of-way at full build out. There is presently a 60-foot right-of-way. The road is maintained by
Adams County. Pursuant to the definition of SETBACK in the Weld County Code, Chapter 23, Article III,
Section 23-3-50, the required setback is measured from the future right-of-way line.
Our most recent traffic count (ADT) reflects approximately 2,300 vehicles on WCR 2 between WCRs 17 and 19
ljacent to this location.
REQUIREMENTS:
Access: The applicant indicated on the plat drawing one access to the facility. Utilize this access point.
Off-Street Parking: The off-street parking including the access drive is covered with recycled asphalt. The
applicant is proposing up to six parking spaces. There is adequate circulation and area to accommodate the
additional parking spaces.
Storm Water Drainage: In the questionnaire, Item No. 8, it asks the applicant to explain how the storm water
drainage will be handled on site. The applicant's answer was, "See attached drainage information." This
document was not included in my packet. Please resubmit for review and approval.
The storage shed, home, and garage/shop area, driveway and parking area already exist.
pc: USR-1494
M-APLANNING-DI?VFI.OPMENT REVIEW VUSR-Use by Special ReviewVUSR-I494.DOC
EXHIBIT
E
4
3
2005-0229
Weld County Planning Department
GREELEY OFFICE
MEMORANDUM DEC h 2004
Kit ‘if-e ,
RECEIVED
TO: CHRIS GATHMAN, PLANNING SERVICES
FROM: CHARLOTTE DAVIS, ENVIRONMENTAL HEALTH
111 gC SUBJEDATE:CT:US -1494 0/2004ANTHONEY & DIANE GODDARD
Cc
COLORADO CC:
Environmental Health Services has reviewed this proposal for a Machine & Welding
shop. We have no objections to the proposal, however, we do recommend that the
following conditions be part of any approval:
We recommend that the following requirements be met prior to allowing the plat to be
recorded:
1 . The septic system serving the house and shop shall be reviewed by a Colorado
Registered Professional Engineer. The review shall consist of observation of the
system and a technical review describing the systems ability to handle the
proposed hydraulic load. (existing use and estimated 6 full time employees) The
review shall be submitted to the Environmental Health Services Division of the
Weld County Department of Public Health and Environment. In the event the
system is found to be inadequately sized or constructed the system shall be
brought into compliance with current Regulations.
2. The applicant shall submit a waste handling plan, for approval, to the
Environmental Health Services Division of the Weld County Department of Public
Health & Environment. The plan shall include at a minimum, the following:
1) A list of wastes which are expected to be generated on site (this should
include expected volumes and types of waste generated).
2) A list of the type and volume of chemicals expected to be stored on site.
3) The waste handler and facility where the waste will be disposed (including
the facility name, address, and phone number).
We recommend that the following requirements be incorporated into the permit as
conditions that must be met prior to issuance of building permits:
1. A stormwater discharge permit may be required for a
development/redevelopment/construction site where a contiguous or non-
contiguous land disturbance is grater than or equal to one acre in area. Contact
the Water Quality Control Division of the Colorado Department of Public Health
and Environment at www.cdphe.state.co.us/wq/PermitsUnit for more information.
We recommend that the following requirements be incorporated into the permit as
development standards:
1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and
Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for
final disposal in a manner that protects against surface and groundwater
contamination.
2. No permanent disposal of wastes shall be permitted at this site. This is not
meant to include those wastes specifically excluded from the definition of a solid
waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S.,
as amended.
3. Waste materials shall be handled, stored, and disposed in a manner that controls
fugitive dust, fugitive particulate emissions, blowing debris, and other potential
nuisance conditions.
4. The applicant shall operate in accordance with the approved "waste handling
plan".
5. Fugitive dust and fugitive particulate emissions shall be controlled on this site.
6. This facility shall adhere to the maximum permissible noise levels allowed in the
Commercial Zone as delineated in 25-12-103 C.R.S., as amended.
7. Adequate handwashing and toilet facilities shall be provided for employees and
patrons of the facility.
8. Any septic system located on the property must comply with all provisions of the
Weld County Code, pertaining to Individual Sewage Disposal Systems.
9. The facility shall utilize the existing public water supply. (Mountain View Water
Users)
2
10.All potentially hazardous chemicals must be stored and handled in a safe manner
in accordance with product labeling and in a manner that minimizes the release
of hazardous air pollutants (HAP's) and volatile organic compounds (VOC's).
11.If applicable, the applicant shall obtain a stormwater discharge permit from the
Colorado Department of Public Health & Environment, Water Quality Control
Division.
12.The operation shall comply with all applicable rules and regulations of the State
and Federal agencies and the Weld County Code.
3
(..ecif(,) Imo— kO�
�;le . lhe�e tk not
t--Cirl alWeld County eferral
' November 1, 2004
C.
COLORADO
The Weld County Department of Planning Services has received the following item for review:
Applicant Anthony& Diane Goddard Case Number USR-1494
Please Reply By November 28, 2004 Planner Chris Gathman
Project A Site Specific Development Plan and Special Review for a Use by Right,
Accessory Use or Use by Special Review(Machine and Welding Shop) in the A
(Agricultural) Zone District
Legal Lot A of RE-2862; pt of the E2SW4 of Section 33, Ti N, R67W of the 6th P.M.,
Weld County, Colorado.
Location 'A mile west of CR 19; north of and adjacent to CR 2.
Parcel Number 1469 33 000020
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
Weld County Planning Commission Hearing (if applicable) December 21, 2004
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
X We have reviewed the request and find no conflicts with our interests.
❑ See attached letter. •Comments: Upon C-Call2,La [c,)' u ,a ct(R.Ot ( F r� 46-t Vrl(1
Signature rTh Date t/ (
Agency 2,(-s(\A Jvq laN4ii are a
•:•Weld County Planning Dept. 4.918 10`"Street, Greeley,CO.80631 •(970)353-6100 ext.3540 ❖(970)304-6498 fax
6i
KitWeld County Referral
' November 1, 2004
C.
COLORADO
The Weld County Department of Planning Services has received the following item for review:
Applicant Anthony& Diane Goddard Case Number USR-1494
Please Reply By November 28, 2004 Planner Chris Gathman
Project A Site Specific Development Plan and Special Review for a Use by Right,
Accessory Use or Use by Special Review (Machine and Welding Shop) in the A
(Agricultural)Zone District
Legal Lot A of RE-2862; pt of the E2SW4 of Section 33, Ti N, R67W of the 6th P.M.,
Weld County, Colorado.
Location 1/2 mile west of CR 19; north of and adjacent to CR 2.
Parcel Number 1469 33 000020
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
Weld County Planning Commission Hearing (if applicable) December 21, 2004
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
❑ e have reviewed the request and find no conflicts with our interests.
d See attached letter.
Comments:
Signature / r/�` Date // 99-6
Agency //1(7//t7 /u 5/-P Cif
1h/ a,CJ
+Weld County Planning Dept. ❖918 10Street, Greeley,CO.80631 4(970)353-6100 ext.3540 ❖(970)304-6498 fax
a DEPARTMENT OF BUILDING INSPECTION
Weld County Administrative Offices
918 10th Street, Greeley, CO 80631
WEBSITE: www.co.weld.co.us
Phone (970) 353-6100, Ext. 3540
Fax(970) 304-6498
C.
COLORADO
November 29, 2004
Anthony& Diane Goddard
USR-1494
A Site Specific Development Plan and special Review permit for a use by right, accessory use, or Use by
Special Review ( Machine and Welding Shop) in the A (Agricultural) Zone District.
1. A building permit shall be obtained prior to the construction of any new building and change of use of the
existing building and cargo container.
2. A plan review is required for each building for which a building permit is required. Plans shall include a floor
plan. Plans shall bear the wet stamp of a Colorado registered architect or engineer. Two complete sets of plans
are required when applying for each permit. Provide a Code Analysis Data sheet provided by the Weld County
-lanilding Department with each Building permit application.
3. Buildings shall conform to the requirements of the various codes adopted at the time of permit application.
Currently the following has been adopted by Weld County: 2003 International Building Code; 2003 International
Mechanical Code; 2003 International Plumbing Code; 2003 International Fuel Gas Code; and the 2002 National
Electrical Code and Chapter 29 of the Weld County Code.
4. The building will probably be classified as F-1 (Manufacturing). The Cargo container will be classified as S-1
(Storage) The maximum amount of indoor and outdoor storage of nonflammable solids and nonflammable and
non combustible liquids shall not exceed the amounts in Table 414.2.4 of the International Building Code. The
building including the bathroom shall be accessible to persons with disabilities. Fire resistance of walls and
openings, construction requirements, maximum building height and allowable areas will be reviewed at the plan
review. Setback and offset distances shall be determined by the Zoning Ordinance.
5. Building height shall be measured in accordance with the 2003 International Building Code for the purpose of
determining the maximum building size and height for various uses and types of construction and to determine
compliance with the Bulk Requirements from Chapter 27 of the Weld County Code. Building height shall be
measured in accordance with Chapter 23 of the Weld County Code in order to determine compliance with offset
and setback requirements. Offset and setback requirements are measured to the farthest projection from the
building.
Please contact me for any further information regarding this project.
Singgrely,
i,oger lgll
Building Official
Service,Teamwork,Integrity,Quality
)<, l /
00H'stilrg'
Weld County Referral
November 1, 2004
VIIDe.
COLORADO
The Weld County Department of Planning Services has received the following item for review:
Applicant Anthony& Diane Goddard Case Number USR-1494
Please Reply By November 28, 2004 Planner Chris Gathman
Project A Site Specific Development Plan and Special Review for a Use by Right,
Accessory Use or Use by Special Review (Machine and Welding Shop) in the A
(Agricultural)Zone District
Legal Lot A of RE-2862; pt of the E2SW4 of Section 33, T1 N, R67W of the 6th P.M.,
Weld County, Colorado.
Location 1/2 mile west of CR 19; north of and adjacent to CR 2.
Parcel Number 1469 33 000020
The application is submitted to you for review and recommendation. Any comments or recommendation you
consider relevant to this request would be appreciated. Please reply by the above listed date so that we may
give full consideration to your recommendation. Any response not received before or on this date may be
deemed to be a positive response to the Department of Planning Services. If you have any further questions
regarding the application, please call the Planner associated with the request. Please note that new
information may be added to applications under review during the review process. If you desire to
examine or obtain this additional information, please call the Department of Planning Services.
•
Weld County Planning Commission Hearing (if applicable) December 21, 2004
❑ We have reviewed the request and find that it does/does not comply with our Comprehensive Plan
❑ We have reviewed the request and find no conflicts with our interests.
❑ See attached letter. (' l _
Comments: on91}ro �GV1d5GGcp . 4vcM-tYl_ tvl'sr - f c-cc rtYl� SUc(e S 15 �1 Oh\
‘-‘rt,nri 00/1- . tcn a 6k Yi11LG `9nL Y.I� Ui`15TZt11CX AX �1/�
5tbr w�-c, I
Signature Date -To:A-
Agency T L 414 IN1 1 CO
4 Weld County Planning Dept. ❖918 10'"Street, Greeley,CO.80631 +(970)353-6100 ext.3540 +(970)304-6498 fax
\�\,i1ll'�1ili/ � ORE_
GREATER BRIGHTON ���`ti
FIRE PROTECTION DISTRICT F j
425 South Main Street R S
Brighton,Colorado 80601 E `er T
;, www.gbfpd.org pioicQtO�
. 'v
Weld County Department of Planning Services 'tilling Dep.. November 5,2004
Attn: Chris Gathman Weld County Planning Depept
918 10th Street GREELEY OFFICE
q04
Greeley, Colorado 80631
NOV 1 0 2004
Subject: Goddard—Case#USR-1494 RECEIVED
Dear Chris,
The following comments are made in response to the above noted site plan review.The Uniform
Fire Code, 1997 Edition, and other codes or standards referenced within the Fire Code, governs
these comments and resulting requirements.
General Comments:
I. No water supplies for fire protection are currently available to this site. Therefore,
approved onsite storage of adequate water supplies for firefighting operations shall be
provided. In lieu of the requirement for the storage of two hours of water supply
(approximately 240,000 gallons),the Fire District will accept an approved cistern—with
a minimum capacity of 10,000 gallons, and equipped with an approved means for the
refilling of and drafting there from—so as to provide adequate flows during the time
needed to establish a tanker shuttle operation.The cistern shall be provided with the
means to monitor the water level therein and shall initiate a local (onsite)alarm to
indicate when the water level has fallen below a predetermined minimum level—as
determined by the Fire District. It shall be the responsibility of the property owner to
maintain the water level in the cistern at capacity.
2. The access/driveway,from Weld County Road 2 to the proposed parking lot, shall have a
minimum width of 20 feet, unobstructed by parked vehicles,and a minimum
unobstructed vertical clearance of 13 feet 6 inches. This access shall be constructed of an
all weather surface capable of supporting Fire District apparatus—maximum weight of
72,000 pounds—and crowned or sloped to provide runoff.
Should there be any questions concerning these requirements,please do no hesitate to contact this
office.
Res ectfully,
Kris Krengel
Deputy Fire Marshal
Cc: File—USR-1494 (Weld)