HomeMy WebLinkAbout20072722.tiff SITE SPECIFIC DEVELOPMENT PLAN AND USE.SPECIAL
REVIEW(USR)APPLICATION
iiiFOR PLANNING DEPARTMENT USE DATE RECEIVED:
RECEIPT#/AMOUNT# /$ CASE#ASSIGNED:
APPLICATION RECEIVED BY: PLANNER ASSIGNED:
Parcel Number: 1 307 -23 - 0- 00 -01 8
(12 digit number-found on Tax I.D. information, obtainable at the Weld County Assessors Office,or www.co.weld.co.us).
Legal Description SW/4SW/4 , Section 23 , Township 2 North, Range 65 West
Flood Plain: No Zone District: Industrial , Total Acreage: 40_00, Overlay District
Geological Hazard: No , Airport Overlay District:
FEE OWNERS OF THE PROPERTY:
Name: Kerr-McGee Gathering LLC
Work Phone# 303-298-3608 Home Telephone:7ao-`Yaf-Z0000Email Address:
Address: 1999 Broadway, Suite 3700 City/State/Zip: Denver, CO 80202
OIL AND GAS LEASEHOLD OWNER:
Name: Kerr-McGee Rocky Mountain LLC, c/o Joe Lorenzo
Work Phone# 303 206 3600 Home Tetephone: Tao-9a9-Woo Email Address:Joe.LorenzoWnadarko.com
Address: 1999 Broadway, Suite 3700 City/State/Zip: Denver, CO 80202
• APPLICANT OR AUTHORIZED AGENT(See Below:Authorization must accompany applications signed by Authorized Agent):
Can-fae* : C.nr y/ l)rttrrck 7aa-qa9-1,052)
Name: Kerr-McGee Gathering LLC
Address: 1999 Broadway, Suite 3700 City/State/Zip: Denver, CO 80202
Business Telephone: 303-296 3C00 Fax No: 303-296-3601
--7(243-q q.-ca000
PROPOSED USE:
Kerr-McGee Gatheinq LLC ("KMG) intends to use this site as a compressor station and liquid terminal site
location.
I (We) hereby depose and state under penalties of perjury that all statements, proposals, and/or plans submitted with
or contained within the application are true and correct to the best of my(our) knowledge. Signatures of all fee owners
of property must sign this application. If an Authorized Agent signs, a letter of authorization from all fee owners must
be included with th application. If a corporation is the fee owner, notarized evidence must be included indicting that
the signatory h t legal auth to sign for the corporation.
5- -o7
Signature: ner Agent Date Signature: Owner or Authorized Agent Date
•
EXHIBIT
1 t
2007-2722
• 2. Executive Summary
2.1 DESCRIPTION OF INTENDED USE
This Application for an amended Use by Special Review Permit is submitted by Kerr-McGee
Gathering LLC ("KMG") as successor in interest to KN Wattenberg Transmission LTD. KMG
currently uses this site as a liquid terminal site to remove liquid condensate from natural gas and for
a compressor station to compress gas for transportation through the pipelines together with additional
equipment as identified on the attached Special Review Plat. KMG does not intend to change the
nature of the use of the site,but may modernize equipment over a period of time. It is KMG's intent
to update this site for land use permitting purposes.
2.2 SITE IMPROVEMENTS
A. KMG constructed this liquid terminal site and compressor station with improvements as identified
on the attached Special Review Plat. The proposed improvements are a fan cooler and radio tower
station which are also detailed.
2.3 CHARACTERISTICS OF INSTALLATION
Construction is expected to begin on the fan cooler and radio tower station as soon as KMG receives
building permits. A photo of this type of installation is included in this application for reference(See
Graphics).
2.4 CHARACTERISTICS OF MAINTENANCE
• B. The compressor station operates 365 days per year, 7 days per week, and 24 hours per day and is
designed so that it may be operated unattended. An automated emergency shut down system will
constantly monitor conditions at the station and will shut down the entire station in an emergency. A
call out system, operated on an uninterruptible power supply, will notify KMG of station shutdowns
or any operational problems.
2.5 RELATIVE PLANS
• Noise: All requirements set forth in applicable COGCC regulations regarding Noise will be
met by KMG in its operations. Exhaust from all engines, motors and related equipment shall
be vented in a direction away from occupied buildings where practical.
• Vibration: All requirements set forth in applicable COGCC regulations regarding Vibration
will be met by KMG in its operations. No unusual vibration is anticipated from the proposed
operation.
• Air and Water Quality: All requirements set forth in applicable COGCC regulations regarding
Air and Water Quality will be met by KMG in its operations. KMG will comply with the
Colorado Department of Public Health and Environment regulations by filing an Air Pollution
Emissions Notice (A.P.E.N.) and any other additional required application data, if production
volumes exceed required thresholds, and will install emissions control devices as warranted to
obtain required reductions of ozone precursors. The COGCC sets forth specific requirements
for casing depth in order to protect ground water sources. Produced water will be hauled
away and properly disposed of in accordance with COGCC regulations.
• • Odor: All requirements set forth in applicable COGCC regulations regarding Odor will be
met by KMG in its operations. No noxious, prolonged or unusually high amounts of odor are
expected from the proposed operation.
2-1
Hudson Compressor Station
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
• • Visual Impacts: All requirements set forth in applicable COGCC regulations regarding Visual
Impacts will be met by KMG in its operations. The permanent facilities will be painted in
accordance with COGCC regulations in a manner so as to harmoniously blend with the
surrounding environment. The site will be reclaimed to as near the original grades as
practicable.
• Wildlife Impacts: All requirements set forth in applicable COGCC regulations regarding
Wildlife will be met by KMG in its operations. No significant impact of wildlife is expected.
KMG's Environmental Coordinator has performed a site inspection and has cleared this
location for any environmental issues.
• Public Safety: The completed site is surrounded with a chain-link fence and gate with
adequate lock. The station will be monitored daily by KMG personnel. A complete
Emergency Response Plan has been prepared and reviewed by the local Fire Authority.
(Protection Plan).
• Access Roads: KMG will utilize the existing access road from WCR 18. The access road is
constructed to accommodate emergency vehicles and shall be properly engineered with a 20'
width, an aggregate base course surface of 6 inches compacted to a minimum density of 95%
of the maximum density. The road shall be properly graded and culverts shall be utilized
where necessary.
•
•
Hudson Compressor Station 2-2
T2N-R65W-23: SW1/4SW1/4
Weld County. Colorado
• •
Hull, Cheryl
om: Beimgraben, Craig
nt: Monday, April 16, 2007 6:50 AM
o: Dokken, Peder
Subject: Wattenberg Towers Details - needing Land Approval
Attachments: Tower Drawing.pdf; tri-antenna_array.pdf; dish_antenna.pdf; omni-whip-antenna.pdf
Peder,
As a follow-up to the proposed towers to be installed in the Wattenberg field, please verify that the following are acceptable
from the Land side (zoning, permitting, etc):
• Tower
• Actual height will likely be around 100 feet. However, the towers could be extended to 120 feet for future
expansion.
• Free standing -no guyed wires.
• Details have been noted in the attachment.
• Antennas
• 2 Dish Antennas
• Each up to 4 feet in diameter(may be smaller).
• Details have been noted in the attachment. Actual antenna could vary slightly from photo.
• 1 Panel Array Antenna
• Array consists of 3 flat panel antennas, approximate dimensions 1'wide and 4' tall.
• Details have been noted in the attachment. Actual antenna could vary slightly from photo.
• Omni-whip antenna
• Approximate dimensions 2 inches round, and 4 feet long.
• • Details have been noted in the attachment. Actual antenna could vary slightly from photo.
Please let me know if I can provide any further details.
Thanks,
Craig Beimgraben
ITS Enterprise Computing -Wireless Network Systems
Anadarko Petroleum Corporation
office: 832-636-2407
craig.beimgraben@anadarko.com
KM t
Tower Drawing.pdf tri-antenna_array.p dish_antenna.pdf omni-whip-antenna.
(41 KB) df(395 KB)... (313 KB) pdf(279 KB)...
•
1
• • - >-
{ •
, 15
)I 04 \ � (
, o \ ) -
• \ \ 60
! i \! ( -
Ln
~ i' _ b� I g \
t% ! r ) [ . 1H , -
j ! ` - ! , ! ` \ ! ; ; \
iri
) )
!
! {
\ § „::!LJ !
a in
iii-
\ }(„
• \ \\ „
2
eri
oe e DI
"
OM W6L
\ \ § § \ j
\ . . , . . -~
• ` , , , e,w: r a, _, _
30.110
/s' , \��, , , , 91Z V5187 `\ � - ~ _
_ �, _, _. � _. \ _ ,_95
HyperL+r ai
caianunlcaticrrls
aii Technologies • 'cr •i a..
• Individual Fed Models(3 Inputs into 3 Antennas)
Frequency Gain Antenna Connectors Includes Part Number
2.4 GHz 14 dBi* N-Female (3) 120° Sector Antennas HK2414-120
(1) Array Mounting System
2.4 GHz 17 dBi* N-Female (3) 120° Sector Antennas HK2417-120
(1)Array Mounting System
2.4 GHz 20 dBi* N-Female (3) 120° Sector Antennas HK242O-120
(1)Array Mounting System
Description
The HyperGain® Sectorized Omni Array features our high performance 2.4 GHz 120°sectorial antennas. Each of the three
antennas in this array can be adjusted individually (0-20° up or down tilt) to compensate for the geography of the installation
location.This helps ensure maximum coverage of the array for service providers in the 2.4GHz ISM band.
Flexibility of Single or Individual Feeds •$'
.
Ideal for smaller applications, the sectorized omni array is available as a single fed system (1 - ..t
input into 3 antennas). Since each antenna is fed from a 3-Way signal splitter, only a single *l�'j
radio/amplifier is required. As the system grows additional capacity can be added by simple ` '
adding more base station radios and bypassing the splitter's array, thus feeding each antenna
from a separate radio. Single fed models feature a industrial grade 3-Way signal splitter(with N- "•n -
Female or RP-TNC Jack connectors) and three 2 ft. (0.6m) WBC400 jumper cables. _
• (Signal Splitter Detail)
For higher system capacities, the array can be purchased as a individual fed system (each antenna fed individually).The
advantages of this type of system includes higher gain than the single fed systems and better isolation of each of the three
antennas. Interference from adjoining antennas is reduced thus improving performance.
The sectorized omni arrays are designed for all-weather operation.They feature heavy-duty plastic antenna radomes and
stainless steel mounting systems.The array can be mounted directly onto masts PA" to 2" (31.7 to 50.8mm) in dia using the
provided U-Bolts or bolted directly to square masts/beams up to 3'/4" (82.5mm) square.The mounting bracket can also accept
3" (76.2 mm) U-Bolts (not included)for larger masts.
Additional Product Photos
14 dBi* Array 17 dBi* Array 17 dBi* Array shown in 20 dBi* Array
down-tilt confi•uration
elk 11,
ul
'I . '.' IF
�t'
wa. la, FAA{-'.� cd, 3$2.,
HyperUnk e-mail:sales@hyperllnktech.com•tel:561-995-2256•fax:561-995-2432
TedinOlOgleityINC web:www.hypedinktedi.com•1201 Clint Moore Road•Boca Raton FL 33487
ci�gyouM[� { a�9'
Lii,..
ciiigiesamil L'AIP
�
oiti
0 2.4 GHz Sectorized Omnidirectional Array
Tri-Antenna Array •
Applications and Features
Applications: • 2.4 GHz ISM Band e,,
• IEEE 802.11b and 802.11g Wireless LAN s 6 4
a :
• Point to Multi-Point Systems
• Wireless Broadband Systems % d '�,
t 4t, t
Features: • Tri-Antenna Array z, ^ ^
• High performance sectorial antennas °� : Y *,,;:t
• 360° coverage ,r ._. V. d y, ' ,"
• 0-20° mechanical up/down tilt I see
F a• t
- ,
• Available in single fed or individual fed models
• Single fed models feature 3-Way signal splitter and jumper cables IiihrHy" ' -
• DC ground lightning protection
• Can be mounted to round or square masts (17 dBi Version Shown)
• Stainless steel construction for all-weather operation
• Vertical polarization
• Available in 14 dBi*, 17 dBi* and 20 dBi* versions
Models
• Single Fed Models(1 Input into 3 Antennas)
Frequency Gain Splitter Connectors Includes Part Number
2.4 GHz 14 dBi* N-Female (3) 120° Sector Antennas HK2414-120NF 0. (1) 3-Way Signal Splitter w/N-Female Connectors
(3) 2 ft. WBC400 Jumper Cables- N-Male to N-Male
(1)Array Mounting System
RP-TNC Jack (3) 120° Sector Antennas HK2414-120RT
(1) 3-Way Signal Splitter w/RP-TNC Jack Connectors
(3) 2 ft. WBC400 Jumper Cables- N-Male to RP-TNC Plug
(1)Array Mounting System
2.4 GHz 17 dBi* N-Female (3) 120° Sector Antennas HK2417-120NF
.... (1) 3-Way Signal Splitter w/N-Female Connectors
(3) 2 ft. WBC400 Jumper Cables- N-Male to N-Male
it r (1) Array Mounting System
RP-TNC Jack (3) 120° Sector Antennas HK2417-120RT
-- (1) 3-Way Signal Splitter w/RP-TNC Jack Connectors
(3) 2 ft. WBC400 Jumper Cables- N-Male to RP-TNC Plug
(1) Array Mounting System
2.4 GHz 20 dBi* N-Female (3) 120° Sector Antennas HK2420-120NF
(1) 3-Way Signal Splitter w/N-Female Connectors
-.-., (3) 2 ft. WBC400 Jumper Cables - N-Male to N-Male
(1) Array Mounting System
RP-TNC Jack (3) 120° Sector Antennas HK2420-120RT
-- (1) 3-Way Signal Splitter w/RP-TNC Jack Connectors
(3) 2 ft. WBC400 Jumper Cables- N-Male to RP-TNC Plug
(1) Array Mounting System
•
Hyperilic e-mail:sales@hypedinktech.com•tel:561-995-2256•fax:561-995-2432
T� web:www.hypedinktech.com•1201 Clint Moore Road•Boca Raton FL 33487
,vi
LHyperLi s �, = fi ',�
Technologies , ; ' , " °
•
Specifications
Models HK2414-120 I HK2417-120 I HK242O-120
Frequency 2400 -2500 MHz
Antenna Gain 14 dBi* 117 dBi* 120 dBl*
Polarization Vertical
Horizontal Beam Width 120° 120° 120°
(Individual antenna)
Vertical Beam Width 15° 6.5° 6.5°
(Individual antenna)
Lightning Protection DC Ground
Power Rating (Single Fed) 25 Watts
Antenna Radome Material UV-inhibited Plastic
Mounting System Material Stainless Steel
Mounting (Round Mast) 1y4"to 2" (31.7 to 50.8 mm) dia.
Mounting (Square Mast/Beam) 31/4" (82.5 mm) square max.
Dimensions 20" (508 mm) x 17" 39" (990 mm) x 17" 39" (990 mm) x 17"
**(O.D. Panels Fully Retracted) (432 mm) O.D.** (432 mm) O.D.** (432 mm) O.D.**
Weight 14 lbs. (6,3 kg) 31 lbs. (14 kg) 44 lbs. (20 kg)
RoHS Compliant Yes
*Antenna gains specified when sectors are individually fed.
• RF Antenna Gain Patterns
90' 90'
120' • so" I20" _/„_ rV, s0°
•;}... 3D` 750° f✓y, .„• •- .',`",' ,/ .� 3p°
Ise- -t 4, .t ii_-A.rA-.1�� 0°780" -- -4, k. (�; -%•--a 0°
.7"7.:--;•-. .:'...i.:".1.,� 330° 210° \ : %�;. . -..-!` •, 330'
,C
240' • ^ 390` 240' 300'
270° 270'
Single Fed Array Individual Fed Array
Guaranteed Quality
This product is backed by Hyperlink's Limited Warranty.
•
/•/r/p punk e-mail:sales@hyperlinktech.com•tel:561-995-2256•fax:561-995.2432
IT••dnol'_ web:www.hypedinktedr.com•1201 Clint Moore Road•Boca Raton FL 33487
ØHerLit Ccoiarhirpia�Uq�-
Ik
• 5.8 GHz 29 dBi ISM / UNII Band High Performance Parabolic Model: HG5829D
Dish Wireless LAN Antenna
Applications and Features
Applications: • 5.8GHz UNII applications
5a "• 5.8GHz ISM applications
• 5.8GHz Wireless LAN systems
• Long-range Directional Applications ±,
• Point to Point,Point to Multi-point Systems h
Optional Radome "it''".
• Wireless Bridges g
Cover
• Backhaul Applications
Features: Superior performance , ' .:
• Aluminum reflector dish €.*:
• UV Stable light gray polymer finish '
• All weather operation
• Vertical or horizontal polarized mounting
• Includes lift and swivel mast mount kit
• Optional radome cover kits available
• RoHS Compliant
• Description
Superior Performance
The HyperGain®5.8GHz High-Performance Parabolic Dish W Fi Antenna is ideal for directional 5.8GHz ISM/
UNII band applications.It features 29 dBi with a 6°beam-width.These antennas can be oriented for either
vertical or horizontal polarization. •
Rugged and Weatherproof
The reflector dish of these antennas are constructed from high quality aluminum which gives them superior , % .
strength.The dish is coated in a light gray UV-inhibited polymer for durability and aesthetics.The small F 5 ,v
^
diameter of the dish helps minimize wind loading.
These antennas are supplied with a tilt and swivel mast mount kit.This allows installation at various degrees of .
incline for easy alignment.The HG5829D can be adjusted up or down from 0°to 30°.
Radome Cover Kits
HyperGain®Radome Covers are an ideal way to provide additional protection to our parabolic dish
r .�}'' antennas.These light weight radome kits feature fiberglass construction and UV stable gray finish.
.;,' ..lit," X' . - Drain holes are provided on the radome cover to help prevent moisture build-up inside the dish
;
antenna.
3
e
These radome kits bolt directly to the dish antennas with the provided stainless steel hardware.Drilling
• mounting holes in the antenna is not required.The radome cover can be attached to existing antennas
y t1already mounted in the field or pre-assemble to the antenna before mounting.
Hyperavk e-mail:sales®hypedinktedr.com•tel:561-995-2256•fax:561-995.2432
Technologlesf web:www.hyperlinktedt.com•1201 pint Moore Road•Boca Raton FL 33487
ail
:tK1i:;;. -'i: es
'txr,f 3"� �'rO11YtY5ttYliCitltYft$
y.
Limp
• Specifications
Frequency 5725-5850 MHz
Gain 29 dBi
Polarization Horizontal or Vertical
Horizontal Beam Width 6°
Vertical Beam Width 6°
Front to Back Ratio 35 Db
Impedance 50 Ohm
Max.Input Power 100 Watts
VSWR <1.5:1 avg.
Weight 13.2 lbs.(6 kg)
Diameter 23.6 in.(600 mm)
Mounting 2 in,(50.8 mm)diameter mast max.
-40°C to to 85°C
Operating Temperature (-40"F to 185'F)
Lighting Protection DC Short
Connector N-Female
RoHS Compliant Yes
Radome Cover Part Number HGR-06
Wind Loading Data
• Wind Speed Loading With Radome
(MPH)
100 113 lb. 751b.
125 177 lb. 116 lb.
RF Antenna Patterns
HG5829D 90' 90.
120,ri y _ _ 60" 120'iY `� ___ 60'
/Y
150' t_.•-'+,I • y 3D' <•-,.:.I,,, :• "..--
- --f..- ft /��.��
' .-t-;
210. "� "' .. •"* i 330° 219' \71/:://-711.21.- ''d N.NI 330'
✓ • '4-' �a.--' 300"
240 - - 300' 240'
270' 270°
Horizontal Vertical
III
HyperUnke-mail:sales@hypedinktech.tom•tel:561-995-2256•fax:561-995-2432
'� web:www.hypedinktech.com•1201 dint Moore Road•Boca Raton FL 33487
HYPettlif „:40,rAlinSeira Commanlcatlans
T@Cf11]OlOgl@S
• 900 MHz Professional 8 dBi High Performance Omni Antenna
for ISM, GSM and Wireless LAN Systems
Model: HG908U-PRO
Applications and Features
Applications: • 900MHz ISM Band
• Wireless LAN systems
• Multipoint applications
• Non Line of Sight(NLOS) `
• GSM t� s
• SCADA §• Wireless Video Links Cellular Band
• 900MHz Cellular Band g , r , ? ,
Features: • Superior performance
• Rugged industrial grade design , .v ;,.. .-
• Lightweight fiberglass radome
• All weather operation
• Integral N-Female connector
• Includes heavy-duty steel mast mounting brackets
Description
• The HyperGain® HG908U-PRO is a high performance omnidirectional antenna designed for the 900 MHz ISM band. It is ideally
suited for multipoint, Non Line of Sight (NLOS) and mobile applications where high gain and wide coverage is desired.Typical
applications include 900MHz Wireless LAN, SCADA, Wireless Video Links and 900MHz Cellular band applications.
This antenna features an integral N-Female type connector that mounts through the wall of an equipment enclosure. Included
with the HG908U-PRO is a dual u-bolt mast mounting kit. Consisting of a heavy-duty steel bracket and a pair of U-bolts,this kit
allows installation on masts up to 2.0" in diameter.
This omni antenna's construction features a rugged 1.58' diameter white fiberglass radome for durability, aesthetics and long
service life. It is designed for all weather operation.
Specifications
Electrical Specifications
Frequency 900-928 MHz
Gain 8 dBi
Vertical Ream Width 16 degrees
Impedance 50 Ohm
Max.Input Power 100 Watts
VSWR < 1.5:1 avg.
• HyperUnk e-mail:sales@hypedinktech.com•tel:561-995-2256•fax:561-995-2432
1ednaktglessNVC web:www.hypedlnktedi.com•1201 Clint Moore Road•Boca Raton FL 33487
ii:i a.M�a�q
HyperLinsimapi communications
Technoiogi
o es
• Mechanical Specifications
Connector Integral N-Female
Weight 2.8 lbs. (1.3 Kg)
Length 47.5 in. (1.2 m)
Radome Diameter 1.58 in. (40.1 mm)
Base Diameter 1.71 in. (43.4 mm)
Radome Material White Fiberglass
Mounting 11/." to 2" dia. mast max.
(31.7mm to 50.8mm dia.)
Polarization Vertical
Operating Temperature -40° C to to 85° C
(-40° F to 185° F)
Rolls Compliant Yes
RF Antenna Gain Patterns
90' 90'
150. y,, :�\ 3D. 160" �.:r--�„vl '" 19•
/- 330" 210'':�� •"�"--,�..:.....:3f '•• •`,j" 330`
210° -\:'' •"r�;`L...'r. ',. '•.`�
t
240- ' 300' 240' "300'270' 270°
Vertical Horizontal
This product is backed by Hyperlink's Limited Warranty.
•
e-mail:sales@hyperlinktecom•tel:561-995-2256•fax:561-995-2432
KJC rh.web:www.hypedinktedr.com•1201 Clint Moore Road•Boca Ratan FL 33487
• 3. Use By Special Review Questionnaire
3.1 EXPLAIN, IN DETAIL,THE PROPOSED USE OF THE PROPERTY.
Kerr-McGee Gathering LLC ("KMG") currently operates at this site a liquid terminal facility to
remove liquid condensate from natural gas and for a compressor station to compress gas for
transportation through the pipelines together with additional equipment as identified on the attached
Special Review Plat.
3.2 EXPLAIN HOW THIS PROPOSAL IS CONSISTENT WITH THE INTENT OF THE WELD COUNTY
COMPREHENSIVE PLAN.
The station and improvements comports with the intent and stated goals of the Weld County
Comprehensive Plan in that it is planned in being assembled in a consolidated and coordinated
manner. Utilities, services and roads already exist.
3.3 EXPLAIN HOW THIS PROPOSAL IS CONSISTENT WITH THE INTENT OF THE WELD COUNTY
COUNTY CODE,CHAPTER 23(ZONING)AND THE ZONE DISTRIT IN WHICH IT IS LOCATED.
In particular, this proposal avoids any interference with the operation of prime farmland within the
County or encroachment upon residential or other incompatible land uses. It will also contribute to
the expansion of the County's industrial economic base by providing an essential function in the
production of natural gas in the County. The operation of the station and improvements will not
impose any new burdens or costs upon the County and will be a self-sustaining operation. No
currently productive agricultural lands or residential areas will be impacted.
S 3.4 WHAT TYPES OF USES SURROUND THIS SITE? EXPLAIN HOW THE PROPOSED USE IS
CONSISTENT AND COMPATIBLE WITH SURROUNDING LAND USES.
The current station site is located within an Agricultural Zone District and therefore, additional
consideration is taken to ensure that it is established and operated in a manner that is compatible with
exisiting and planned uses in the area. The station itself has been classified as an Industrial Zone.
The soil for the property is composed of Valent and Osgood sands.
The compression, treatment and processing of natural gas produced in Weld County is a necessary
component of marketing this valuable resource. Providing the required treatment will not only foster
the development of an important economic base but, in so doing, will contribute to the convenience
and general welfare of the present and future residents of the County. The station contributes to the
County's tax base with little or no adverse impact in terms of additional roads or other governmental
expenditures.
3.5 DESCRIBE, IN DETAIL, THE FOLLOWING:
3.5.1 How many people will use this site?
Employees, maintenance personnel, contractors and representatives of other companies may be
present at the site from time to time, but normally the station will be unattended. A maximum of 10
people may be at the site at one time.
3.5.2 How many employees are proposed to be employed at this site?
• The station will be operated by the same personnel. One operator currently maintains the Station for
4 to 8 hours per day.
Hudson Compressor Station 3-1
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
• 3.5.3 What are the hours of operation?
The station operates 24 hours per day, 7 days per week,365 days per year.
3.5.4 What type and how may structures will be erected (built) on this site?
The major structures erected at the station include:
7-Compressors housed in 2 Compressor Buildings
2-Teg Dehydrators
1 —Heat Medium Heater
1 —Lubricating Oil Tank, 7260 Gallon
1 —Ambitrol Storage Tank,2915 Gallon
1 —Methanol Tank—500 Gallon
1 —Methanal Tank— 10,150 Gallon
1 —Mineral Spirit Tank, 500 Gallon
5—Condensate Tanks 12,690 Gallon
4—Jacket Water Coolers
4—Aftercoolers
A Radio Tower and fan cooler are proposed equipment to be installed at the site.
3.5.5 What type and how many animals, if any,will be on site?
• None.
What kind (type,size,weight)of vehicles will access this site and how often?
Operating personnel will use pickups to access this site daily.
3.5.6 Who will provide fire protect to this site?
Hudson Fire Protection District.
3.5.7 What is the water source on the property(both domestic and irrigation).
Bottled water shall be provided and will be utilized for drinking and hand washing.The water from
the well that was drilled under the Well Permit will be used for the restroom facilities and for the
intermittent cleaning of the equipment at the station. Potable water will be supplied in bottles.
3.5.8 What is the sewage disposal system on the property (existing and proposed)?
Bathroom facilities shall be available at the compressor site on this parcel. Portable toilets shall be
used during the construction of the site and removed upon completion. The compressor station has a
domestic water well for restroom facilities with septic tank and leach field.
3.5.9 If storage or warehousing is proposed,what type of items will be stored? The storage
tanks are itemized on the plot plan attached.
•
Hudson Compressor Station 3-2
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
Use By Special Review Questionnaire
•
3.6 EXPLAIN THE PROPOSED LANDSCAPING FOR THE SITE. THE LANDSCAPING SHALL BE
SEPARATELY SUBMITTED AS A LANDSCAPE PLAN MAP AS PART OF THE APPLICATION
SUBMITTAL.
There is no landscaping proposed for the site. Unused areas will remain undeveloped range land.
3.7 EXPLAIN ANY PROPOSED RECLAMATION PROCEDURES WHEN TERMINATION OF THE USE
BY SPECIAL REVIEW ACTIVITY OCCURS.
Applicant will remove all above ground equipment, buried and above ground piping and any
concrete structures within 18 inches of the land surface. This site will be graded to match the
contours of the surrounding properties.
3.8 EXPLAIN HOW THE STORM WATER DRAINAGE WILL BE HANDLED ON THE SITE.
Kerr-McGee will adhere to all Colorado Dept. of Public Health and Environment's rules and
regulations in regards to storm water discharge.
3.9 EXPLAIN HOW LONG IT WILL TAKE TO CONSTRUCT THIS SITE AND WHEN CONSTRUCTION
AND LANDSCAPING IS SCHEDULED TO BEGIN.
Construction is expected to begin within 30 days of obtaining the required building permits. The
station is currently operating.
• 3.10 EXPLAIN WHERE STORAGE AND/OR STOCKPILE OF WASTES WILL OCCUR ON THIS SITE.
Any waste products will be disposed of off-site.
•
Hudson Compressor Station 3-3
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
• 5. Site Selection
FOR COMMERCIAL SITES,PLEASE COMPLETE THE FOLLOWING INFORMATION
BUSINESS EMERGENCY INFORMATION:
Business Name: Kerr-McGee Gathering LLC
Address: 9501 WCR 47 Hudson, CO 80642
Business Owner: Kerr-McGee Gathering LLC
Address: 635 N. 7th Avenue, Brighton,CO 80601
List three persons in the order to be called in the event of an emergency:
Rob Smith, Sr. Plant Foreman, 635 N. 7th Ave.,, Brighton, CO 80601 303-655-4339
Dave Mildenberger,Pipeline Foreman, 635 N. 7th Ave., Brighton,CO 80601 303-655-4306
Troy Person, Area Superintendent, 635 N. 7th Ave., Brighton, CO 80601 303-655-4308
• Business Hours: 7 AM to 5 PM Days: Monday—Friday
Security Cameras on Location
MISCELLANEOUS INFORMATION:
Large Compressor Building:
Number of entry/exit doors in this building: 12 doors E, W,N, S
Small Compressor Building
Number of entry/exit doors in this building: 6 doors E,W,N, S
Air Compressor Building
Number of entry/exit doors in this building: 4 doors N& S
West Gas Dehydrator Building
Number of entry/exit doors in this building: 2 doors E& W
East Gas Dehydrator Building
• Number of entry/exit doors in this building: 2 doors E& S
Hudson Compressor Station 5-1
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
• •
MISCELLANEOUS INFORMATION (CONT'D):
•
Pump Building
Number of entry/exit doors in this building: 1 door S
Pump Building
Number of entry/exit doors in this building: 1 door S
Is alcohol stored in building?No
Are drugs stored in building?No
Are weapons stored in building?No
UTILITY SHUT OFF LOCATIONS:
Main Electrical: Air Compressor Building—West side of Bldg
• Gas Shut Off: Each building has its own gas shut off.
Exterior Water Shutoff: Outside Office Building, South side of Bldg
Interior Water Shutoff: Inside Office Building, South side of Bldg
•
Hudson Compressor Station 5-2
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
• 13. Emergency Response Contact List
Incident Contact Phone Number Comments
Fire,explosion, Hudson Fire Protection 911 or
serious injury District (303) 536-0161
Weld County Sheriffs 911 or
Dept. (970) 392-4565
COGCC (303)894-2100
Fire,explosion, Hudson Fire Protection 911 or
associated with loss District (303) 536-0161
of well control
Weld County Sheriffs 911 or
Dept. (970) 392-4565
COGCC (303)894-2100
Wild Well Control, Inc. (281) 353-5481 Commercial well control contractor.
Reporting required for spills of crude
Spill or release COGCC 303-894-2100 oil, produced water,or E&P waste
exceeding 5 bbl or all spills that
impact surface or ground water.
Reporting required for spills
Weld County Sheriffs 911 or impacting surface water or for
Dept. (970) 392-4565 reportable quantity spills of CERCLA
hazardous substances.
• Colorado Department of Reporting required for spills
Public Health and impacting surface water or for
Environment reportable quantity spills of CERCLA
hazardous substances.
Reporting required for spills
US EPA 800-227-8917 impacting surface water or for
reportable quantity spills of CERCLA
hazardous substances.
Reporting required for spills
National Response 800-424-8802 impacting surface water or for
Center reportable quantity spills of CERCLA
hazardous substances.
KMG and Contractor Troy Person , (303)655-4339 Operations-Midstream
Contacts Area Supt
Rob Smith (303)655-4306 Operations-Midstream
Sr. Plant Foreman
Dave Mildenberger (303)655-4308 Operations-Midstream
Pipeline Foreman (303)559-4036(P)
Hudson Compressor (303)659-9429 Emergency Numbers
Station (303)259-7996(P)
Brighton (303)659-5922 24 Hour Telephone Number
•
Hudson Compressor Station 13-1
T2N-R65W-23: SW1/4SW1/4
Weld County, Colorado
Hello