HomeMy WebLinkAbout20081158.tiff Swi L4 heat' WELD COUNTY CODE ORDINANCE 2008-2 IN THE MATTER OF REPEALING AND REENACTING, WITH AMENDMENTS, CHAPTER 29 BUILDING REGULATIONS, OF THE WELD COUNTY CODE BE IT ORDAINED BY THE BOARD OF COUNTY COMMISSIONERS OF THE COUNTY OF WELD, STATE OF COLORADO: WHEREAS, the Board of County Commissioners of the County of Weld, State of Colorado, pursuant to Colorado statute and the Weld County Home Rule Charter, is vested with the authority of administering the affairs of Weld County, Colorado, and WHEREAS, the Board of County Commissioners, on December 28, 2000, adopted Weld County Code Ordinance 2000-1 , enacting a comprehensive Code for the County of Weld , including the codification of all previously adopted ordinances of a general and permanent nature enacted on or before said date of adoption , and WHEREAS, the Weld County Code is in need of revision and clarification with regard to procedures, terms, and requirements therein . NOW, THEREFORE, BE IT ORDAINED by the Board of County Commissioners of the County of Weld , State of Colorado, that certain existing Chapters of the Weld County Code be, and hereby are, repealed and re-enacted , with amendments, and the various Chapters are revised to read as follows. CHAPTER 29 BUILDING REGULATIONS Article I - No change Article II Code Standards Sec. 29-2-10 Standards Sec. 29-2-20 International Building Code Sec. 29-2-30 International Residential Code Sec. 29-2-40 International Mechanical Code Sec. 29-2-50 International Plumbing Code Sec. 29-2-60 International Fuel Gas Code Sec. 29-2-70 National Electrical Code Sec. 29-2-80 Uniform Code for the Abatement of Dangerous Buildings Sec. 29-2-90 International Energy Conservation Code Sec. 29-2-100 State and federal requirements Sec. 29-2-110 Mobile and manufactured home installation standards Sec. 29-2-120 Area of special flood hazards standards Sec. 29-2-130 Repealed Remainder of Index page - No change. 2008-1158 PAGE 1 ORD2008-2 Amend Sec. 29-2-70. National Electrical Code. The publication of the National Fire Protection Association , known as the National Electrical Code, 2008 Edition , NFPA No. 70-2008, is incorporated by this reference as a part of this Building Code for the purpose of establishing standards for the inspection of electrical installations and issuance of electrical permits in the County, with the following amendments: Remainder of Section - No change Repeal and Reenact Sec. 29-2-90. International Energy Conservation Code. The publication of the International Code Council, Inc. , known as the International Energy Conservation Code, 2006 Edition , is incorporated by this reference as a part of this Building Code, with the following amendments: A. Amend Section 201 . 3 by substituting "adopted Electrical Code" for the " ICC Electrical Code" in all sections throughout this Code. B. Amend Section 401 . 3, first sentence as follows , "A permanent certificate shall be posted in a conspicuous location on the job site." Table 402. 1. 1 Simplified Insulation Requirement Single-Family Prescriptive Zone 5 Glazing Ceiling/Floor Wall Floor Basement Slab on Crawlspace U-Factor Over Outside Wall Grade Wall Air Perimeter 0.35 R-38 R-19 R-30b R-10 /R13 R-10, 2ft. R-10/R-13 Max. Min . R13+5a Min. Min.' Min. Min.' a. "13+5" means R-13 cavity insulation plus R-5 insulated sheathing. b. Or insulation sufficient to fill the framing cavity; R-19 minimum . c. The first R value applies to continuous insulation, the second to framing cavity insulation; either insulation meets the requirement. Amend Sec. 29-3-70. Moved buildings. A - No change. B. In addition, the following items are required for moved buildings of Group R Occupancies: 1 . Building/structural : a. Egress windows and window wells shall be installed according to the IRC and to the adopted Energy Code. b through d - No change. 2. Insulation. Ceilings shall be insulated to R-38. Walls that are opened shall have the cavity completely filled with insulation or be insulated to R-19. 2008-1158 PAGE 2 ORD2008-2 Foundations systems shall be insulated according to Section 29-2-90 of this Chapter. 3. Mechanical . Mechanical systems and equipment serving the building , heating , cooling, or ventilation needs shall comply with Section 403 of the International Energy Conservation Code except sizing as required by Section 403.6. Gas appliances must meet IMC requirements for combustion air, venting , and required shutoff valves. 4. Glazing . Double-pane or storm windows shall be present throughout the dwellings with safety glazing installed where required by the IRC. 5. Electrical a through c - No change. d . Receptacles, as specified , shall be spaced and installed at locations required by NEC. e and f - No change. g . Arc-fault circuit interrupter protection must be installed, as required by the Electrical Code. h. Electrical devices, fixtures, and penetrations shall be durably sealed to limit infiltration, according to adopted Energy Code . Remainder of Section - No change. BE IT FURTHER ORDAINED by the Board that the Clerk to the Board be, and hereby is, directed to arrange for Colorado Code Publishing to supplement the Weld County Code with the amendments contained herein, to coincide with chapters, articles, divisions, sections, and sub sections as they currently exist within said Code; and to resolve any inconsistencies regarding capitalization , grammar, and numbering or placement of chapters, articles, divisions, sections, and sub-sections in said Code. BE IT FURTHER ORDAINED by the Board if any section, subsection, paragraph, sentence, clause, or phrase of this Ordinance is for any reason held or decided to be unconstitutional , such decision shall not affect the validity of the remaining portions hereof. The Board of County Commissioners hereby declares that it would have enacted this Ordinance in each and every section , subsection , paragraph , sentence, clause, and phrase thereof irrespective of the fact that any one or more sections, subsections, paragraphs, sentences, clauses, or phrases might be declared to be unconstitutional or invalid . 2008-1158 PAGE 3 ORD2008-2 The above and foregoing Ordinance Number 2008-2 was, on motion duly made and seconded , adopted by the following vote on the 12th day of May, A. D. , 2008. BOARD OF COUNTY COMMISSIONERS WELD COUNTY, COLORADO ATTEST: David E. Long , Chair Weld County Clerk to the Board William H . Jerke, Pro-Tem BY: Deputy Clerk to the Board William F. Garcia APPROVED AS TO FORM : Robed D. Masden County Attorney Douglas Rademacher Publication: March 12, 2008 First Reading : March 31 , 2008 Publication: April 9, 2008, in the Fort Lupton Press Second Reading : April 21 , 2008 Publication: April 30, 2008, in the Fort Lupton Press Final Reading : May 12, 2008 Publication: May 21 , 2008, in the Fort Lupton Press Effective: May 26, 2008 2008-1158 PAGE 4 ORD2008-2 Hello