HomeMy WebLinkAbout20101536.tiff • PRELIMINARY DRAINAGE REPORT • • 2010-1536 • Preliminary Drainage Report For Heartland Renewable Energy, LLC SE '/4 of Section 25 T4N R65W Operated by Colorado Green, LLC A subsidiary of Heartland Renewable Energy, LLC • Ass P io AGPROfessionals, LLC 4350 Highway 66 Longmont, CO 80504 (970) 535-9318 March 2009 Revised 5/22/2009 Revised 8/5/2009 Revised 9/15/2009 • Revised 2/15/2010 Heartland Renewable Enerev • Certifications I hereby certify that this report for the preliminary drainage design of Heartland Renewable Energy was prepared by this professional engineer, licensed to practice in Colorado. To the best of my professional knowledge,judgment and belief, these plans meet the provisions of the Weld County storm drainage criteria, and the Weld County Use by Special Review and Site Plan Review Preliminary Drainage Report Outline. ,cp.0 0 L/c, 1 O '•1\s • cP 427 • 6.c •151)P1.41• \\V •��‘ r/4?NAL ECG 0) Travis Hertneky, PE • AgProfessionals • 2115/2010 Preliminary Drainage Report Page 2 of 7 Heartland Renewable Enerpv • Project Description Heartland Renewable Energy is a new renewables-based gas production plant planned for construction in south central Weld County Colorado. This proposed facility will import digestible feed stocks such as cattle manure, food wastes and agricultural wastes and process them in anaerobic digesters to produce commercial quantities of natural gas. The proposed facility will be located primarily in Parts of the SE / of Section 25, T4N, R65W, 6th PM. This facility is located approximately 1/4 mile northwest of Weld County Road 49 and 40 intersection and approximately 7 miles southeast of the town of LaSalle, CO. The site that the plant will be constructed on is an approximate 80 acre parcel located on the sand hills between the west bank of the Box Elder Creek located approximately 4 miles east and the east bank of Beebe Draw located approximately 1.25 miles west. The site is currently native grass and is used for livestock grazing and has oil and gas production equipment on the site. This site is situated at a relatively higher elevation in relation to the local terrain and does not have any major hydrologic features such as natural drainages or irrigation canals located within or adjacent to the proposed facility. The site is predominantly the same as it has historically been with the exception of the oil • and gas footprints, the construction of WCR 49 and the construction of the downstream Gilmore ditch. Investigations indicate that groundwater is present under parts of the site at depths of approximately 3011. These investigations indicate that a shallow water table will likely not be a major concern for construction or operations. Groundwater Investigations There are no current groundwater production wells located on this property, however there are existing permitted wells located in both the up gradient and down gradient quarter sections. The recorded groundwater levels of the existing production wells are 175ft up gradient and 120ft down gradient. Soilogic's preliminary subsurface exploration continued to a depth of approximately 30ft at various locations throughout the site, and did not encounter any indications of seasonably high groundwater. Three groundwater monitoring wells have been drilled on and adjacent to the proposed site. Two of the three groundwater monitoring wells intercepted water. MW02 located on the western edge of the proposed site intersected groundwater and the water level on the day of drilling has been determined to be approximately 44ft. MW0I and MW03 did not exhibit static water on the day of drilling. Subsequent readings of the monitoring wells have indicated consistent readings of the static water elevations in MW0I and MW02. Both show a depth to groundwater of approximately 30ft and a static elevation of 4772.811 in M W01, • and 4777.9 in MW02. The deepest excavations on this site will be approximately 21ft for 2/15/2010 Preliminary Drainage Report Page 3 of 7 Heartland Renewable Energy • the construction of the stormwater pond located directly adjacent to wells M W0l and MW02. This provides a separation of approximately 9ft from high water elevation to bottom of pond. Drainage Basin and Sub-Basins This site is generally a west facing slope, however much of the site never historically drained offsite due to the sand hill nature of the site. Any storm water that does drain from the site, generally flows in a west-northwest direction toward the Gilmore ditch located approximately '/2 mile from the North West corner of the site. Depending on the storm event, runoff may have overtopped the ditch and flowed to Beebe Draw, and then north into Lower Latham Reservoir. No mapped 100-year floodplain affects this property. The USGS topographic maps indicate that a minor area up gradient of the site historically flowed through the site. A site survey of the area indicates that much of this water will flow to natural low depressions in the sand hill topography. The final design for ensuring that run-on water is adequately diverted will include a combination of retention in the natural sand hills and diversion of water along the east edge of the facility. Run-on diversions will be sized to safely convey the expected flows around the facility. Diversion design will depend on the final site layout and will likely consist of elevating • the eastern edge of the site, construction of diversion berm or channels to divert the run- on along the east edge to the north boundary of the property. Drainage Design Criteria and Preliminary Drainage Design This proposed facility will be new construction and the site will be leveled and graded to ensure proper drainage and a suitable site for construction. Existing oil and gas facilities provide the only major site constraints that the grading must match. Existing oil and gas pipelines running through the site will be relocated around the proposed facility. Overall the site will be graded to drain to the west and north to a single retention pond. It is anticipated that all storm water will be conveyed to this single retention pond with open conveyances sized to adequately carry the estimated peak runoff from a 25yr-24hr storm from the developed site. From the NOAA Atlas 2 the estimated rainfall from the 25yr-24hr storm event is 3.0". The runoff volume and flows will be estimated using the NRCS curve number methods. All estimations will be performed either manually or using readily available software and spreadsheets such as NRCS TR-55, or Colorado NRCS Rectangular Waste Storage Pond Design Computations spreadsheet developed by State Engineer John Andrews. The runoff waste storage pond will be designed as a retention system with zero discharge outside of the design storm event. The preliminary design was developed with the • conservative assumption that there will be approximately 30 acres of hard surfaced or 2/15/2010 Preliminary Drainage Report Page 4 of 7 Heartland Renewable Energy • impermeable production area. This estimate included the footprint for all the digesters and associated buildings and storage tanks. A CN of 97 for the impermeable areas was used for the preliminary design. In the event that areas around the digesters and buildings are finished with a permeable surface such as gravel the design volume will decrease. The soil amendment pads located to the north and south of the digester footprint will be native soil and have windrows of the post-digestion compost product. The native soil for the pad areas is classified as either a Valent sand or a Vona loamy sand. These soils have a hydrologic soil classification of A and B respectively. It is assumed that the worst case scenario is when these pads are nearly empty and the pads would most closely resemble the NRCS description of a "newly graded area" and have CN's of 77 and 86. The preliminary design estimates the runoff from the design storm to be 13.8 ac-ft. An additional 7.3ac-ft has been allowed for winter storage of accumulated runoff and management flexibility. No process water from the digestion process will be stored in this pond and thus no additional storage volume is needed. The pond will have a permanent depth gauge installed and will be marked to indicate the maximum normal operating volume that will still allow for storage of the design storm runoff. After a large storm event the facility will dewater to the pump down mark. All of the runoff water will be recycled back into the digestion process. The runoff pond will have an emergency spillway installed that is capable of adequately handling the expected runoff from the 25yr-24hr storm event while protecting the structural integrity of the pond itself. The pond inlets will be protected from erosion with poured concrete spill protection that will continue from the top of the inlet and extend onto the bottom of the pond. The pumping system will likely be either a floating pump or a vertical turbine sitting on a wet well. The dewatering system will be designed to draw the pond down to the dewatering mark in approximately 15 days. The runoff pond will be lined with a geo-membrane liner constructed from either 60mi1 High-density polyethylene(HDPE)or 30mi1 XR-5. Sediment basins will be lined with a compacted clay liner of 1.5ft thick and will have a tested seepage rate when completed of less than 1.0x10-bcm/sec (1/32 in/day). The preliminary geotechnical report performed by Soilogic, Inc. indicates that there is a substantial quantity of clay present in subsurface horizons at varying depths from lft to nearly 25ft. The bore hole labeled B-6 located approximately 300ft from the pond indicates a CL soil located from approximately 1 ft to the bottom of the boring at 25.5ft. This lean clay has 65.2% passing the no. 200 sieve and a PI of 16. Testing indicates that this soil has relatively high clay content and will likely be suitable for a compacted clay liner. The conveyance channel from the south pad to the pond will facilitate solids settling and will be oversized to adequately handle the design flows with a sediment load. Sediment settling basins may be constructed, and will be lined with a compacted clay liner and protective soil blanket. The solid settling system will be designed to facilitate cleaning with on-site equipment such as standard front end loaders in order to encourage proper maintenance. Preliminary runoff estimates were determined using a conservative approach to size the conveyance channel and emergency spillway. NRCS EFH2 method • was used to determine the estimated peak runoff, and determined with a weighted curve 2/15/2010 Preliminary Drainage Report Page 5 of 7 Heartland Renewable Energy • number of 87 the peak expected runoff from the 100yr-24hr storm will be 180 cfs. This peak runoff was used to size the western conveyance channel and emergency spillway. The preliminary channel sizing of 12ft wide, 1.5ft deep with 4:1 sideslopes and a 1% slope is adequate convey the runoff The channel will also have a berm located west of the channel to prevent any overtopping. Preliminary calculations are provided in the appendix. Estimated run-on flows from the adjacent up gradient area to the east are approximately 7 cfs for the 25yr-24hr storm event, and 15 cfs for the 100yr-24hr storm event as estimated by NRCS EFH 2 shown in appendix. Diversion of this water will likely be performed by site grading and elevating the work pad higher than the adjacent grade. Final diversions will be designed to adequately divert the 25yr-24hr storm event. Conclusions This preliminary drainage design for Heartland Renewable Energy has been developed in accordance with 6 CCR 1007-2 Section 14. The plan meets or exceeds all standards and expectations set forth by Weld County for this type of facility. This system is designed as a zero discharge system with a 25yr-24hr design storm. Generalizations regarding the percentage of impervious area were made with the most conservative numbers used for the planning stages. Upon construction approval by Weld County Public Health and Environment, and Colorado Department of Public Health and Environment, final design • and construction drawings will be developed. All calculations and designs will be developed using industry standard methods, practices and software. • 2/15/2010 Preliminary Drainage Report Page 6 of 7 Heartland Renewable Energy • Appendices • NRCS Soil Report for proposed site • Well Map • Permitted water wells within± 1 mile of proposed site • FIRM Flood Map • Preliminary Peak Runoff Calculations • Rectangular Waste Storage Pond Design Computations • Preliminary Emergency Spillway Dimensions • Preliminary West Channel Sizing • Preliminary Geotechnical Report • LTE Boring log, Monitoring well completion diagrams • Potential Run-On determination • Proposed Drainage Layout • • 2/15/2010 Preliminary Drainage Report Page 7 of 7 n O m a a.w. / .a U5 BOUKAA I _ I I Whelan you dIgi so,AMENDMENT ST .- yl 1 ` _wEL� m= rc n 111 200' BUFFER ` 130' SETBACK } .. zoo' BUFFER - GAS wrED o,/ as li ,4W0UND WWIT _ _ — -- �� cn5�vrxl� € ?� Il o _ —.Fx1571NG DID/cns Rang -N'` 1 s DIGESTER a� Lw WI w I °.5a s �aossso. o""`"POND 1 _ __I 150 S TB�.CK I I '?? 9 1 DIGESTER o, ME R ccz.w 1 as�xo.s `� MESTER Kh° C I, y ■ 1 I c ANAEROBU IGESTERS s , occnw 1 MESTER . 5A 1 Ci AVE-LC 1 C% a PPE 110110.2 �1 I 1 K 1� GOC1 5I �u 1' 1 ? u I �� 11 ss 5 o0\BUFFEd Q 1 Q p ��mp."f "ww"d ..� 1 n I \ 5.O n 1 5, nP� .s .I OVUM.iGA51W I1. wee spa + 6`' L r 1 r ^+� A ` GAS 1:-----ii }s---- _ _ HT ces— Is WELL \� 11 Dili 1 �s. t . SWR I ' 200• BUFFER P p _i_. -- /"; 150' al NSA 1 Jf I - - -5---_� i 150' SETBACK N 200 BUFFER / -1-L---11 `v 4 — 150' �E1tAck zoo' Burrl_R _ DAARV tGE$O1Th DRY ` / u _ "�13 i _ 200' SETBACK H _ `. _ I , . .I r1 rs I 1��GCF' 8•' GAS LINES ' GAS WEI" ewe[o-was _ ••--1.--..—..—..-1.R "S LII`1 1 55«<s MOUND PROPER TANK 1- NOAI F I -ic:. BAT" ., +�Tr PF —.m. WELD COUNTY ROAD 40 ' STRUCTURE LEGEND 32 FOG STORME TAW NI SPAM 0-10.01110 J2 MOSIRS 010 Ha 2 47 2241.SLAW. HEARTLAND RENEWABLE ENERGY . . . III I IIIII I .°new �AGPR01,.rt,L , . ill ' 9I1i11 PROPOSED DRAINAGE - + � NORM 4350 Highwayhwrey •Lonfax: CO Soso+ + + I i .tea^^o (970)535-9318 w fu:(970)535-9854 IF vm \ \' I ea -.-. \ 1\ \ l{/ ( ' / OO, \ �\\ � °Min r \/— _�_ c /4(}��.�(/j `'J � \ ��//".�I/ ---111 M j„,-,1.1„:r F �� \ — _,/ Ar4 3 � r�l sees/ �. � aaa "_ ic.\ \ �� • i. N\c, aV-hT.n rr (� /'� m \.,. e 1 0'�\ s) ) (\ \(— _ell�a ° °Mien' \r 1 l'Im ' ' x'Bl __ / /I. \ e \ a eO]I n S iF II-7 / (y '1477823 f/1 15547 ' Y � :14_1_,±6 t � c s �(, c , i 75'. \ 3 $83 ll = Jf1 GWL 7- ISck- c I° I \ K, y, i' ' _ \ \\ -4.- \1 , _- __ ' ° 5',` lr-f __ r - Cr t ' \ 3s1 \T1, t`Bl\ f 1198)� %.�- n ~ a < 1 \ \\194',\—s \) ,,,, \‘' fib �� 2i ' ' G , G \\ � Kj < s 1+1 f � - ° a sNirc iga r ��1 l Q$�}Q8 ' .,) , X52 . a` o\ N\ 2 � i � I0- A` ;I y I ( /�-v ' ri 4 \ ) c \ Mall if) -.__.y inn sue• r <_ r oeaaC_ grin (-;\".34-C\: . ''J t Pa_.Tand M ae c_�\ > 0% o \ ,+ � 1 l- kdw � M �s l �f ���� ' ':4,1( $+i$ —�:c a 4420q'2-1/1:1 \ . , C. I 2`0004 r ( p J / \�'eso_f #S� I. o — 1c25i211p 1\ \� rt �.J \� i-' n .jam__ I /. 1 _ t 4.\ . " ' ti ;', \ - - - '\�,\ _ "cr`\—` __ sad \ 1 V - ... ° NE �. FROM I �ae�a o-�l� .Teas _ �, N' \\ %eCILITY __ \ '\ o f )` � 0' P� A DFpTHFBO�t l i.: p V4. l ��i �� �; C0L0 ] F WA \. _ of` (N\5'...;;'n }Y�/ !4 LIU V-- 1 f i„ i II \� ( \ /f' -- / \\ real -.': I, -f AGPRO HEARTLAND RENEWABLE ENERGY 4/8/2009 C(131PI FTF I AND F RFS!)I�RCF SOT Ill o ADJACENT WELLS 1 OF 1 • Heartland Renewable Energy Permitted Water Wells within±1 mile of proposed site RECEIPT 9058546 9062270 9063577 9063695 9064295 9064635 9064799 PERMITNO 655 15776 31609 33583 42959 49452 55245 PERMITSUF R F PERMITRPL STAT DATE 3/22/1972 Change in ownership accepted and STAT CODE updated. ACT DATE 3/22/1972 Well permit ACT DESC issued. USE1 IRRIGATION IRRIGATION DOMESTIC DOMESTIC STOCK DOMESTIC DOMESTIC USE2 USES ISSUEDDATE 10/1/1959 10/20/1971 4/4/1972 FIRSTUSE 5/6/1955 7/1/1955 7/26/1967 5/6/1968 9/9/1970 11/20/1971 4/20/1972 ALL UNNAMED ALL UNNAMED ALL UNNAMED ALL UNNAMED LARAMIE FOX LARAMIE FOX ALL UNNAMED AQUIFERI AQUIFERS AQUIFERS AQUIFERS AQUIFERS HILLS HILLS AQUIFERS AQUIFER2 WELL YIELD 1000 1000 15 20 50 15 15 WELL DEPTH 52 72 327 304 310 300 240 WELL LEVEL 15 9 75 142 200 175 138 • WALTERS HOLDERNESS WEIXELMAN BURKE RICHARD& JOHNSON NAME A E DONALD B DUPPER RAY SHELBY KATHY VERN BURKE LLOYD 1572 ADDRESS RT 1 BOX 49 RT 4 BOX 410 RT 1 BOX 99A RT 1 BOX 135 18850 WOR 49 RT 1 BRIGHTON DR ADDRESS2 CITY LASALLE FT COLLINS LA SALLE LA SALLE LA SALLE KERSEY BRIGHTON STATE CO CO CO CO CO CO CO ZIP 80643 80524 80645 80645 80645 80644 80601 SUBDIVNAME LOT 178 BLOCK FILING 221 DIVISION 1 1 1 1 1 1 1 WD 2 2 2 2 1 1 2 COUNTY WELD WELD WELD WELD WELD WELD WELD DES BASIN MGMT_DIST PM S S S S S S S RNG 65 65 65 65 64 64 65 RNGA RDIR W W W W W W W TS 4 4 4 4 4 4 4 TSA TDIR N N N N N N N SEC 26 26 24 24 31 30 24 SECA Q160 NE NE SW SE NW SW SE Q40 SW SW SW SE NW SW SE Q10 COORDNS 0 0 0 0 0 0 0 COORDNSDIR COORDEW 0 0 0 0 0 0 0 COORDEWDIR • ACCURACY QUARTERED QUARTERED QUARTERED QUARTERED QUARTERED QUARTERED QUARTERED • Heartland Renewable Energy Permitted Water Wells within±1 mile of proposed site RECEIPT 9064820 208669 211222 0303529A 03035298 401718 0405997A PERMITNO 55874 117748 118253 155470 155470 197143 198408 PERMITSUF PERMITRPL A STAT DATE 3/24/1972 9/29/1980 1/12/1981 8/23/1989 8/3/1989 6/5/1996 9/6/1996 Exempt wells where no statement of use is required Resubmitted Resubmitted Resubmitted Resubmitted STAT CODE (obsolete). date. date. date. date. ACT DATE 3/24/1972 9/29/1980 1/12/1981 8/23/1989 8/3/1989 6/5/1996 9/6/1996 Well permit Well permit Well permit Well permit Well permit Well permit Well permit ACT DESC issued. issued. issued. issued. issued. issued. issued. USE1 DOMESTIC DOMESTIC DOMESTIC DOMESTIC DOMESTIC DOMESTIC DOMESTIC USE2 STOCK STOCK ISSUED UNDER PRESUMPTION USES 3b-IIA ISSUEDDATE 4/6/1972 12/29/1980 2/10/1981 9/28/1989 9/28/1989 8/7/1996 9/25/1996 FIRSTUSE 4/24/1972 10/31/1937 2/19/1958 ALL UNNAMED ALL UNNAMED ALL UNNAMED ALL UNNAMED ALL UNNAMED LARAMIE FOX ALL UNNAMED AQUIFERI AQUIFERS AQUIFERS AQUIFERS AQUIFERS AQUIFERS HILLS AQUIFERS AQUIFER2 WELL YIELD 15 0 0 0 15 15 15 WELL DEPTH 244 0 0 0 180 280 200 WELL LEVEL 141 0 0 0 65 138 0 • SHELTON SHELTON MARTIN JOHN WHEELER LAND& LAND& THROCKMORT NAME R FARM TROXEL M CATTLE CATTLE ON JERRY FLIPPEN STAN 11767 QUAIL ADDRESS 20171 WCR 49 23043 WCR 42 23043 WCR 42 RD 19108 WCR 47 ADDRESS2 CITY LASALLE GREELEY GREELEY LA SALLE LA SALLE LONGMONT LASALLE STATE CO CO CO CO CO CO CO ZIP 80645 80631 80632 80645 80645 80501 80645 SUBDIVNAME LOT BLOCK FILING DIVISION 1 1 1 1 1 1 1 WD 2 2 2 1 1 2 2 COUNTY WELD WELD WELD WELD WELD WELD WELD DES BASIN MGMT DIST PM S S S S S S S RNG 65 64 64 65 65 64 65 RNGA RDIR W W W W W W W TS 4 4 4 4 4 4 4 TSA TDIR N N N N N N N SEC 24 30 30 26 26 31 25 SECA O160 SE SW SE NE NE SW SW Q40 SE NW SW NE NE NW SW Q10 COORDNS 0 0 0 46 76 2340 620 COORDNSDIR N N S S COORDEW 0 0 0 48 48 300 320 COORDEWDIR E E W W DIST SECT DIST SECT DIST SECT DIST SECT • ACCURACY QUARTERED QUARTERED QUARTERED LINES LINES LINES LINES • Heartland Renewable Energy Permitted Water Wells within±1 mile of proposed site RECEIPT 0405997B 29125 407931 412174 443559 482751 505492 PERMITNO 198408 96439 200040 201924 217261 252172 249110 PERMITSUF VE PERMITRPL A STAT DATE 9/6/1996 9/6/1996 10/22/1996 2/24/1997 4/1/1999 10/1/2001 2/10/2003 Change in ownership Resubmitted Resubmitted Resubmitted accepted and STAT CODE date date. date. updated. ACT DATE 9/6/1996 9/6/1996 10/22/1996 2/24/1997 4/1/1999 10/1/2001 2/10/2003 Verbal approval granted to well Well permit construction Well pen-nit Well permit Well permit Well permit Well permit ACT_DESC issued. contractor. issued. issued. issued. issued. issued. USEI DOMESTIC DOMESTIC DOMESTIC DOMESTIC DOMESTIC DOMESTIC DOMESTIC USE2 STOCK STOCK IRRIGATION ISSUED ISSUED ISSUED UNDER UNDER UNDER PRESUMPTION PRESUMPTION PRESUMPTION USES 3b-IIA 3b-IIA 3b-IIA ISSUEDDATE 9/25/1996 9/6/1996 12/9/1996 3/31/1997 5/4/1999 8/5/2003 4/1/2003 FIRSTUSE ALL UNNAMED ALL UNNAMED LARAMIE FOX LARAMIE FOX LARAMIE FOX LARAMIE FOX LARAMIE FOX AQUIFERI AQUIFERS AQUIFERS HILLS HILLS HILLS HILLS HILLS AQUIFER2 WELL_YIELD 10 0 10 15 12 14 15 WELL_DEPTH 220 0 360 220 300 210 252 WELL LEVEL 65 0 140 70 200 120 165 LOEFFLER • SKYLAR MILLER PEPPLER PRECIADO SCOTT 8 MATTHEW J 8 FLIPPIN HAROLD NAME FLIPPEN STAN FLIPPEN STAN PATRICIA L LARRY D HEATHER A STANLEY D FAMILY TRUST 1351 S 2036 1ST AVE ADDRESS 19108 WCR 47 17108 WCR 47 LINCOLN ST 22511 WCR 40 #297A 19108 CR 47 17043 WCR 394 ADDRESS2 CITY LASALLE LASALLE LONGMONT LASALLE GREELEY LA SALLE LASALLE STATE CO CO CO CO CO CO CO ZIP 80645 80645 80501 80645 80631 80645- 80645- SUBDIVNAME LOT BLOCK FILING DIVISION 1 1 1 1 1 1 1 WD 2 2 1 2 1 2 1 COUNTY WELD WELD WELD WELD WELD WELD WELD DES BASIN MGMT_DIST PM S S S S S S S RNG 65 65 64 65 64 65 64 RNGA RDIR W W W W W W W TS 4 4 4 4 4 4 4 TSA TDIR N N N N N N N SEC 25 25 31 26 31 25 19 SECA 0160 SW SW NE SE NW SW SW 040 SW SW NW SE NE SE SW Q10 COORDNS 580 580 961 300 160 300 500 COORDNSDIR S S N S N S S COORDEW 320 320 2230 528 2480 1610 500 COORDEWDIR W W E E W W W DIST SECT DIST SECT DIST SECT DIST SECT DIST SECT DIST SECT DIST SECT 0 ACCURACY LINES LINES LINES LINES LINES LINES LINES • Heartland Renewable Energy Permitted Water Wells within±1 mile of proposed site RECEIPT 513212 513213 PERMITNO 252115 252116 PERMITSUF PERMITRPL STAT_DATE 7/23/2003 7123/2003 Change in ownership accepted and STAT_CODE updated. ACT DATE 7/23/2003 7/23/2003 Well permit Well permit ACT_DESC issued. issued USE1 DOMESTIC DOMESTIC USE2 ISSUED UNDER PRESUMPTION USES 35-I IA ISSUEDDATE 7/31;2003 7/31/2003 FIRSTUSE LARAMIE FOX LARAMIE FOX AQUIFER1 HILLS HILLS AQUIFER2 WELL_YIELD 15 12 WELL_DEPTH 420 300 WELL LEVEL 120 182 • HOYLAND KENNETH W& NAME WELCH JAMES KATHY L ADDRESS 701 7TH ST P O BOX 462 ADDRESS2 CITY KERSEY LASALLE STATE CO CO ZIP 80644- 80645- SUSDIVNAME LOT BLOCK FILING DIVISION 1 1 WD 2 1 COUNTY WELD WELD DES-BASIN MGMT DIST PM S S RNG 64 64 RNGA RDIR W W TS 4 4 TSA TDIR N N SEC 31 31 SECA Q160 NW NW O40 SE SW Q10 COORDNS 1720 2340 COORDNSDfR N N COORDEW 1500 600 COORDEWDIR W W DIST SECT DIST SECT ACCURACY LINES LINES tocNE QLa a cc a- Q 2 m W„my O V ° 4 ' N 4C m_ ti • w O o i o w c m' .. E 130 0 E i� F- n. Gr['l! z �C CC] Et4,: 88-8 O TK \\�JJ���� C Y7 Z N.. 6' El d • 1 W I � @ r-..7L. K� Q6I .1 9YQCg tle z a p �p - d tm m° qZ2 ° a. 0 'J A Z O O W C::j Y; F5 0 880 1 � y "'n — "07 & C • I — cc = apao �_ 9ammp2 o i G D W< o m B E$g, T WOO U R9 m Ew_ C m C R 1.3 r) O 2 m m L [LL O -......_— _ - _ _ m r T a t `a2Euc ...la qY CFFs . W ; au, m :I= a2 8 E I` % °G E i U c 8 E _ Qc a /j mm m3 2gtoo G/ rE3 `Yaa / 0 O M N) IC) • I — k\ \\ U _ /I w Z — O v N in t° N N K' I dJOtG�!/, ----7 /�/J ==h � � �-...----) I I • KI O .----j...._..m J� G EFH-2 ESTIMATING RUNOFF AND PEAK DISCHARGE Version 1.1.0 SClient: Heartland Renewable Energy County: Weld State: CO Practice: Potential Run-on Calculated By: TEH Date: 3/17/2009 Checked By: Date: Drainage Area: 106 Acres (user entered value) Curve Number: 55 (provided from RCN Calculator) Watershed Length: 3360 Feet Watershed Slope: 3 Percent Time of Concentration: 1.58 Hours (calculated value) Rainfall Type: II Storm Number 1 2 3 4 5 6 7 Frequency (yrs) 1 2 5 10 25 50 100 24-Hr rainfall (in) .00 1.70 2.20 2.60 3.40 3.60 4.00 • la/P Ratio 0.00 0.96 0.74 0.63 0.48 0.45 0.41 Used 0.00 0.96 0.74 0.63 0.48 0.45 0.41 Runoff (in) 0.00 0.04 0.10 0.31 0.38 0.53 (ac-ft) 0.00 0.00 0.35 0.88 2.74 3.36 4.68 Unit Peak Discharge 0.000 0.378 0.292 0.247 0.211 0.232 0.266 (cfs/acre/in) Peak Discharge (cfs) 1 3 7 9 15 i Page 1 of 2 EFH-2 ESTIMATING RUNOFF AND PEAK DISCHARGE Version 1.1.0 Curve number Computation Client: Heartland Renewable Energy County: Weld State: CO Practice: Potential Run-on Calculated By: TEH Date: 3/17/2009 Checked By: Date: Percent (CN) COVER DESCRIPTION Hydrologic Soil Group A B C D OTHER AGRICULTURAL LANDS Pasture, grassland or range fair 70(49) 30(69) - - Total Area (by Hydrologic Soil Group) 70 30 TOTAL DRAINAGE AREA: 100 Percent WEIGHTED CURVE NUMBER: 55 • • Page 2 of 2 EFH-2 ESTIMATING RUNOFF AND PEAK DISCHARGE Version 1.1.0 • Client: Heartland Renewable Energy County: Weld State: CO Practice: Preliminary Peak Runoff Calculated By: TEH Date: 8/3/2009 Checked By: Date: Drainage Area: 76 Acres (user entered value) Curve Number: 87 (user entered value) Watershed Length: 1570 Feet Watershed Slope: 2 Percent Time of Concentration: 0.42 Hours (calculated value) Rainfall Type: II Storm Number 1 2 3 4 5 6 7 Frequency (yrs) 1 2 5 10 25 50 100 24-Hr rainfall (in) .00 1.70 2.20 2.60 3.40 3.60 4.00 la/P Ratio 0.00 0.18 0.14 0.11 0.09 0.08 0.07 • Used 0.00 0.18 0.14 0.11 0.10 0.10 0.10 Runoff (in) 0.68 1.06 1.40 2.09 2.27 2.64 (ac-ft) 0.00 4.31 6.71 8.87 13.24 14.38 16.72 Unit Peak Discharge 0.000 0.842 0.872 0.888 0.899 0.899 0.899 (cfs/acre/in) Peak Discharge (cfs) 43 71 94 143 155 180 • Page 1 of 2 EFH-2 ESTIMATING RUNOFF AND PEAK DISCHARGE Version 1.1.0 Curve number Computation • Client: Heartland Renewable Energy County: Weld State: CO Practice: Preliminary Peak Runoff Calculated By: TEH Date: 8/3/2009 Checked By: Date: Acres (CN) COVER DESCRIPTION Hydrologic Soil Group A B C D FULLY DEVELOPED URBAN AREAS (Veg Estab.) Impervious Areas Paved parking lots, roofs, driveways 29(98) - - DEVELOPING URBAN AREA(No Vegetation) Newly graded area (pervious only) 30(77) 17(86) - • Total Area (by Hydrologic Soil Group) 59 17 TOTAL DRAINAGE AREA: 76 Acres WEIGHTED CURVE NUMBER: 87 • Page 2 of 2 W o act +c. 8mfi�„RR� it 8 t .w 3 IV m .4 o m WC _ .� m m FI O 4,F n u n N �n01 .� Namaa rn 728R §S gz ,,:�1l ti ON N d 2 -V 8NO mm.^- h v.00 tat V O .0 o 7 CI N , 7 O O 1W o m m tic 2.: qq��t�, @ > > g @vv, ]$ 4 N $ O O`s$ &o�y o 08 t� @ 80770 rr"'?'mo8 m c EX• W g$F c v E a O 4 $ 2 a V- 4 C! N g .81-- O ' x_ m O 4m Z = gm � �1F f c&st , '�' li c ei V _ rn a,LL e0 i t 8888888885 $ o m G1 O g ,,p aa2v m c^ria6d > O z § t0i v N 0 Q m tt -8g. 5 -Z kit 111111111111 O . a o r f O N�; as a a a a a a a a as o > o c 20000.. 4Eg W2 ?. o o = C- o0 ov55��e em e > <n erg "4 _ 0N. 0 h �Fi�c‘i mmoe .n d - rc a ax '• m . C N n' W ' t Yy 0 O 0 of O O - O q O W j ¢ O O O O O O O {a0 a 't, I- vl < �q E g ryry .. g �4 �S. :.'�tp �[f� d�iA 41 mm pon' h 1'4 3 v 6 m ti O <..1 >i E 152- Ca Q. ] W Au]mAONflg 88 8 w m m m ! rs �r N 4 N m um 71:7 7:;, e a23 LL in k -f*�hj _-` p �ppm �p W C O.F Oa m m N 4 0 mwm�N 0 m 0 a o c 7 m l O N 0 N 0 0 0 0 0 O 0 a >J f y.. . Q��Q5 5p�'�Q$X55$$Q$$Q5 G�5$�Q5`$�$`$�$�'5+$$ o ei c o t i 0 �= m 3 060000000000 $ co N N V I A �� @ � -a�a 'awn o wX� � az3� aa000000aaao T '� �� ggyog�.5og�yGg�4�g+�4g+gg}g4�y4g�}g4�}g4�}g4� • o ocow -A ^ F py � SaESSa8aaSISS 8 , q mj %r X"' m� ffiv i 0 6 �!2 `a' 00000 occ ooco o M ¢a 1 < 6 a' > o 1,g m o re' tr �sg or ^P'�^nfiei o�lmuwi o .888oa ;8 eL vvo ar8 a 0 -m2 2 au- _ z `d OONo ooNo� a ,..it-' wa 1 m a m t N m �.2 O, a a� o o�ca 'c i fl $ a = . $8$$$$g$$$$$ m a 3 a £ = 1:( c i 8�818!8j8'8�8'8�8!8�8I8 0 0 "m o a E e o qq `� o.Oio 0100ol000c LLO _ m 6m > Q�> � L 3 �� o ti a03 ; 1 1 I I I l°l c! l wawa '8 = i 72 B _ E x 18 ' Ee F. > en5 Im I O a`occ 13 g 8 ` m m m _z g a 0c 0-- o _ Fee . a a8 r5 y ^ Z LIJ a. .. z = 8^ 8m I ylg to ad n e N ,co o B z N L! man wJa `oo .$a-; _ololo m E cc cc 4 g _ `y6.^.. a g8 �+ a' 112 RAJ E `V a• nu g Sy� i.: NI W00 cm$55 QE �'e$ ernes<ea fq rn z a w -E S m m m ;n a c,e. 6 u ^w o uu > c c'N '8`r 8 :i2. 22 L, m0' Z m c in 41,- ,!. ,,i, Q m 1 : _ N¢ < a s 7 c c c �0 c c c a c r 9 C. y c ^m S Y E d 6 S I I ll Ii- la gym; 0. go•• ae nrts.$�x' F2ac vl000888ISo�8 $ wA :_� y, a et .1e.•=1 Wy Ill cele' C a vi., , ,: 0 r2 OI o 0 LL G S y . E & `� c � e[ g 'o r o mma� ds9p - II I f I I i I I P- ZZ ,'88N „, „-'� s 2v ,' <n a2da6E t -W 0 0!800`000 0 JLI 8 a o O m y < a =Z B 3 o c1 ' I Icic 0 O '.., a r N i3 6 °off-mpg . $ I0I I I ( I I I I o�. J '�i 1 mW e en n e +Y'm 3F6Wa a3 $ it a ^f � 'tl-<t siJmt'tpl-:::: ap ^ JJ r1,HH Em 'Y �^ t p 4 g9 .`ga cc z n n S55 8aa. El p oo �N 7.7.1T oao 6 2Sts{ a, �> - z„z1¢m J ! BEBj :-1 s1'`_leI � tt g8 § ga_40 C 4 E , '5 8 7 $ r3.1 np, g. z z�4+} t �' p q a • ¢ y1 a c • a a W C Natural Resources Conservation Service United States [Department' of Agriculture • Trapezoidal Channel Section Participant: Heartland Renewable Energy Location: Weld County County: County, Colorado Designer: TEH Checker: Date: 08/03/2009 Date: Hydraulics Formula, Version 2.2.1 West Channel, at inlet to SB Slope: 0.01 ft/ft Hydraulic Radius: 1.11 'n' value: .0225 Area: 27.00 sq ft Velocity: 7.07 ft/sec Capacity: 190.92 cfs Sideslope: 4:1 Bottom Width: 12 ft Depth of Flow: 1.5 ft. Width @ surface 24 ft • • Natural Resources Conservation Service United States [Department of.Agriculture Weir Flow Formula Solution Participant: Heartland Renewable Energy Location: Weld County County: County, Colorado Designer: TEH Checker: Date: 08/03/2009 Date: Hydraulics Formula, Version 2.2.1 Preliminary Emergency Spillway Weir Coefficient(C): 3.367 Length of Weir: 30 in. Head on Weir: 1.5 ft. Weir Capacity: 185.57 cfs • • Hello